owner’s manual - water maker · pdf fileowner’s manual how to maintain and operate...

31
Part No. 7283578 (Rev. H 10/6/09) OWNER’S MANUAL How to maintain and operate your EcoWater electronic demand water system MODEL ESD 525 Printed on recycled paper EcoWater Canada LTD 5240 Bradco Blvd. Mississauga, Ontario L4W 1G7 Systems tested and certified by NSF Inter- national against NSF/ANSI Standard 44 for water softener performance. Systems tested and certified by the Water Quality Association against NSF/ANSI Standard 44 for water softener performance and against CSA B483.1.

Upload: buidieu

Post on 13-Mar-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Part No. 7283578 (Rev. H 10/6/09)

OWNER’S MANUALHow to maintain and operate your

EcoWater electronic demand water system

MODELESD 525

Printed on recycled paperEcoWater Canada LTD5240 Bradco Blvd. Mississauga, Ontario L4W 1G7

Systems tested and certified by NSF Inter-national against NSF/ANSI Standard 44

for water softener performance.

Systems tested and certified by the WaterQuality Association against NSF/ANSI

Standard 44 for water softener performanceand against CSA B483.1.

2

ECOWATERS Y S T E M S Dimensions

IN

OUT

3--3/8”

32--1/2”

45--1/8”39--1/2”

IN -- OUT

14”

20”

FOR FUTURE REFERENCE, ENTER THE FOLLOWING INFORMATION

MODEL NO.

DATE CODE

WATER HARDNESS GPG

WATER HARDNESS SETTING (see page 15)

SERIAL NO.

INSTALLATION DATE

IRON CONTENT PPM

on rating decal on shipping carton

EcoWater Canada LTD5240 Bradco Blvd. Mississauga, Ontario L4W 1G7

1 -- 800 -- 752 -- 3273

3

ECOWATERS Y S T E M S Introduction

UNPACKING

EcoWater Systems units are shipped from the facto-ry in one master carton. The carton also includes askin pack of small parts needed to assemble andinstall the unit, and this manual.

Thoroughly check the EcoWater System unit forpossible shipping damage and parts loss. Also in-spect and note any damage to the shipping carton.Notify the transportation company if damage is pres-ent. EcoWater is not responsible for in--transit dam-ages.

Remove anddiscard (RECYCLE)all packingmateri-als. We suggest you keep the small parts on theskin--pack until you are ready to use them.

TABLE OF CONTENTSPage

Dimensions / Specifications 2Water / Water Conditioning 4--5Assembly Instructions 6Planning Installation 7Installation Steps 8--11Programming Face Plate--Timer 12--13Features / Options 14--15EcoWater System Unit Operation 16--17Service Information 18--25Repair Parts 26--29Guarantee Bond 30Warranty 31

SAFETY GUIDES

Follow the installation instructions carefully. Failure to install the EcoWater softener properly voidsthe warranty.Before you begin installation, read this entire manual. Then, obtain all thematerials and tools youwillneed to make the installation.Check local plumbing and electrical codes. The installation must conform to them.Useonly lead--free solderand flux for all sweat--solder connections, as required by state and feder-al codes.Use care when handling the EcoWater softener. Do not turn upside down, drop, or set on sharp pro-trusions.Donot locate theEcoWater softenerwhere freezing temperatures occur. Donot attempt to treatwaterover 120°F. Freezing, or hot water damage voids the warranty.Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non--metallic parts.The EcoWater softener requires a minimumwater flow of 3 gallons perminute at the inlet.Maximumallowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressuremay exceed the maximum. Use a pressure reducing valve if necessary. (Adding a pressure reducingvalve may reduce the flow.)TheEcoWater softenerworks on 24 volt--60 hz electrical power only.Be sure to use the includedtransformer and plug it into a nominal 120V, 60 cycle household outlet that is grounded and properlyprotected by an over current device such as a circuit breaker or fuse. If transformer is replaced, useonly the authorized service, Class II, 24 volt, 10 VA transformer.This system is not intended to beused for treatingwater that ismicrobiologically unsafe or of unknownquality without adequate disinfection before or after the system.

European Directive 2002/96/EC requires all electrical and electronic equipment to be disposedof according toWaste Electrical and Electronic Equipment (WEEE) requirements. This directiveor similar laws are in place nationally and can vary from region to region. Please refer to yourstate and local laws for proper disposal of this equipment.

4

ECOWATERS Y S T E M S Water, and Water Conditioning

WATER

Man’s very existence depends on water. It is 1 of thebasic commodities of life. Water is best as natureprovides it, is a common misconception. Practicallyall natural water needs refinement or treatment tomake it safe to drink or more satisfactory to use.

The earth’s water supply cycle starts in the uppercloud layers. As it falls to the earth as rain or snow,it picks up impurities and gases from the atmo-sphere. Landing on earth, it seeps over and throughthe ground, dissolving earth minerals. Passingthrough limestone, it dissolves calcium and magne-sium, the hardness minerals. Iron deposits impartiron to the water. Acidity and sediments are otherwater conditions.

Municipal water supplies come from surface reser-voirs, such as lakes and rivers, or from undergroundreservoirs. Usually, municipalities chlorinate the wa-ter to make it safe to drink. Sediment is removed byfiltration. Tastes and odors are reduced or elimi-nated. The water is conditioned to comply with cer-tain specifications. However, hardness minerals,tastes and odors are not always reduced to themostdesirable levels.

Underground reservoirs provide our private watersupplies. Because the water is raw and untreated, itcan have varying amounts of hardness, iron, tastes,odors, acidity, or combinations of these. Different lo-calities and water levels affect mineral content.

WATER CONDITIONING

Water conditioning is the treatment of four generalconditions. These are: (1) Hardness, (2) Iron, (3)Acidity, (4) Sediments.

(1) HARDNESS is a term to describe the presenceof calcium and magnesium minerals in water. Achemical analysis accurately measures the amountof minerals in grain weight. For example, 1 gallon ofwater with 5 grains per gallon (gpg) hardness hasdissolved minerals, that if solidified, about equalsthe size of 1 ordinary aspirin tablet. Onegallon ofwa-ter, 25 gpg hard, has a mineral content equal in sizeto 5 aspirin tablets. Water hardness varies greatlyacross the country. It generally contains from 3 to100 gpg.

Hardwater affects living in general. Hardnessminer-als combine with soap to make a soap curd. Thecurd greatly reduces the cleaning action of soap.Precipitated hardness minerals form a crust oncooking utensils, appliances, and plumbing fixtures.Even the tastes of foods are affected. A water soft-ener removes the hardness minerals to eliminatethese problems, and others. Pages 16--17 describehow the EcoWater conditioner works.

Sodium Information: Water softeners using sodiumchloride (salt) for regeneration add sodium to thewater. Persons on sodium restricted diets shouldconsider the added sodium as part of their overall in-take.

(2) IRON in water is measured in parts per million(ppm). The total* ppm of iron, and type or types*, isdetermined by chemical analysis. Four differenttypes of iron in water are: Ferrous (clear water),

Ferric (red water), Bacterial and organicallybound iron, Colloidal and inorganically bound iron(ferrous or ferric).

*Water may contain one or more of the four types ofiron and any combination of these. Total iron is thesum of the contents.

Ferrous (clear water) iron is soluble and dissolvesin water. It is usually detected by taking a sample ofwater in a clear bottle or glass. Immediately after tak-ing, the sample is clear. As thewater sample stands,it gradually clouds and turns slightly yellow or brownas air oxidizes the iron. This usually occurs in 15 to30 minutes. An EcoWater conditioner will removemoderate amounts of this type of iron*.

*Capacity to remove clear water iron was tested inthe field by the manufacturer.

Ferric (redwater), and Bacterial and organicallybound ironsare insoluble. This iron is visible immedi-ately when drawn from a faucet because it has oxi-dized before reaching the home. It appears as smallcloudy yellow, orange, or reddish suspended par-ticles. After the water stands for a period of time, theparticles settle to the bottomof the container.Gener-ally these irons are removed from water by filtration.Chlorination is also recommended for bacterial iron.An EcoWater conditioner will remove minimal quan-tities (see specifications) of ferric iron.

continued

5

ECOWATERS Y S T E M S Water, and Water Conditioning

Colloidal and inorganically bound iron is a ferric orferrous form that will not filter or exchange out of wa-ter. In some instances, treatment may improve col-loidal iron water, but always consult a qualifiedwa-ter chemistry lab before attempting to treat it.Colloidal iron water usually has a yellowappearancewhen drawn. After standing for several hours, thecolor persists and the iron does not settle, but re-mains suspended in the water.

Iron in water causes stains on clothing and plumbingfixtures. It negatively affects the taste of food, drink-ing water, and other beverages.

(3) ACIDITY or acid water is caused by carbon diox-ide, hydrogen sulfide, and sometimes industrialwastes. It is corrosive to plumbing, plumbing fix-

tures, water heaters, and other water using ap-pliances. In can also damage and cause prematurefailure of seals, diaphragms, etc., in water handlingequipment.

A chemical analysis is needed to measure the de-gree of acidity in water. This is called the pH of water.Water testing below 6.9 pH is acidic. The lower thepH reading, the greater the acidity. A neutralizer filteror a chemical feed pump are usually recommendedto treat acid water.

(4)SEDIMENT is fine, foreignmaterial particles sus-pended in water. This material is most often clay orsilt. Extreme amounts of sediment may give the wa-ter a cloudy appearance. A sediment filter normallycorrects this condition.

COMPLETE WATER CONDITIONING SYSTEM -- Seldom would all the water conditioners shown below beneeded on onewater supply. The drawing does show the proper sequence location of each conditioner. Notethat only a taste and odor filter is installed after a water softener. All other filters belong before thewater soften-er. Also note that outside faucet lines are before the treated water, and the water heater is after all condition-ing.

NOTE: FOR CLARITY OF THIS DRAWING, NOT ALL WATER CONDITIONERS ARE ILLUSTRATED(REVERSE OSMOSIS SYSTEMS, DISTILLERS, ETC.).

Figure 1

6

ECOWATERS Y S T E M S Assembly Instructions

TYPICAL INSTALLATION DRAWINGS

INLET -- OUTLET OPTIONS

1” copper tube(2 supplied)

1’ x 1” strgt.sweat connector

1’ x 3/4” strgt.sweat connector

1” sweat x 1” or 3/4”pipe thread

floor drain

floor drain

NOTE: Faceplate and supportnot shown for clarity of drawing.

Tie or wire valve drain hose in place,to keep over floor drain.

valve drain hose

valve drain hose

brine tankoverflow hose

brine tankoverflow hose

1--1/2”airgap

120V, 60Hzoutlet

transformer(supplied)

to timer

to timer

1--1/2”airgap

INLET

INLET

OUTLET

OUTLET

3-- valvebypass system

inlet valve

outlet valve

bypass valve

HARDWATERHARD

WATER

CONDITIONEDWATER

Figure 2

INLET -- OUTLET PLUMBING OPTIONS

S ALWAYS INSTALL either an EcoWater bypassvalve, #7129871, or a 3 valve bypass system.By-pass valves allow you to turn off water to the soft-ener for repairs if needed, but still have water inhouse pipes.

S Use 1”... or, 3/4” (minimum) pipe and fittings.

S Use sweat copper... or, threaded pipe*... or, PVCplastic pipe.*

*Sweat soldering is required to adapt to the fittings(1” male) supplied with the EcoWater System Unit,or obtain approved compression adaptors. The fol-lowing special fittings are available from EcoWater.Be sure to comply with all local plumbing codes.

OPTIONAL INLET/OUTLET FITTINGS

#7104546 PVC Nipple --- Use in place ofincluded copper inlet and outlet tubes.

#7129211 Adaptor Fitting, 1–1/2” (2) --- Use inplace of included copper inlet and outlet tubes.

#7120259 Elbow --- Extends inlet and/or outlet inany 90˚ direction.

7

ECOWATERS Y S T E M S Planning Installation

OTHER REQUIREMENTS

S A drain is needed for regeneration discharge wa-ter. A floor drain is preferred, close to the EcoWa-ter conditioner. A laundry tub, standpipe, etc., areother drain options.

DRAIN OPTIONS

STANDPIPE

1--1/2”airgap

drainhose

1--1/2”airgap

drainhose

LAUNDRY TUB

Figure 3

S A 120V--60Hz, grounded, continuously ‘‘live’’,electrical outlet is needed within 10’ of the Eco-Water conditioner.

TOOLS YOU MAY NEED

D common screwdriver D pliers

D cross--point screwdriver D tape measure

SOLDERED COPPER THREADED CPVC PLASTIC

D tubing cutter D hacksaw orpipe cutter

D hacksaw

D propane torch D threading tool D adjustablewrench

D LEAD--FREEsolder and flux

D pipe joint com-pound*

D solvent cement*

D emery cloth,sandpaper or steelwool

D primer

MATERIALS YOU MAY NEED

H bypass valve, or 3 valvesH pipe and fittings as requiredH 7/16” I. D. high quality, flexible hose for the valvedrain,* and brine tank drain.

*VALVEDRAINOPTIONS: Flexible drain hose is notallowed in all localities (check your codes). To makea rigid valve drain run, cut the barbed section off thedrain fitting for access to the 1/4” pipe threads. Thenplumb a rigid drain as needed. Purchase a fitting, asneeded, to adapt rigid tubing to the 1/4” threads.

Figure 4

SELECT INSTALLATION LOCATION

Consider all of the following when selecting aninstallation location for the EcoWater conditioner.

S To condition all water in the home, install the Eco-Water conditioner close to the water supply inlet,and before all other plumbing connections, ex-cept outside water pipes. Outside faucets shouldremain on hard water to avoid wasting condi-tioned water and salt (see drawing on page 6).

S Anearby drain is needed to carry away regenera-tion discharge water. A floor drain is preferred,with a laundry tub, standpipe, etc., as other op-tions (check your local codes).

S The EcoWater conditioner works on 24 voltsonly. A transformer is included to reduce120V--60 Hz house power. Provide an approved,grounded outlet within 10’ of the conditioner. Thetransformer has an attached 10’ power cable forconnection between the outlet and the timer.

S Position the EcoWater conditioner at least 6” fromsurrounding walls, or other appliances, to allowaccess for adding salt and servicing.

S Locate the EcoWater conditioner, in the plumbingsystem, after all other installed water condition-ing equipment, except for a taste and odor filter.A taste and odor filter is installed after all equip-ment.Always install the EcoWater conditionerBEFORE the water heater. See the SafetyGuides on page 3. To reduce the risk of hot waterback-up, conditioned water piping between theEcoWater conditioner and water heater shouldbe as long as possible.

S Install the EcoWater conditioner in a place waterdamage is least likely to occur if it develops aleak.

S If installing the conditioner in an outside location,be sure to provide protection from the elements,contamination, vandalism, and sunlight heat.The sun’s heat can melt plastic parts.

8

ECOWATERS Y S T E M S Installation

Figure 5

9

ECOWATERS Y S T E M S Installation

2

7

)

out

in

drain fitting

hose clamp

10

ECOWATERS Y S T E M S Installation

ground wire

clamp (2)

B

A

2

Use the included ground clamp kit to jump acrossthe inlet and outlet copper tubes.

Figure 6

18

Bypass valve(s) should always remain in softwaterservice position. Position in “bypass” only if neededfor softener repair.

groundclamp

11

ECOWATERS Y S T E M S Installation

PROGRAM THE TIMER...page 12. AFTERPROGRAMMING, COMPLETE INSTALLA-TION STEPS 16 AND 17 BELOW.

26

17

12

ECOWATERS Y S T E M S Programming the Electronic Demand Timer

DOWN keypadUP keypaddisplay

SELECT keypadRECHARGE keypad

Figure 7

When the transformer is plugged in, a model codeshows in the face plate display for the first few sec-onds. The model code for your water softener isS525, as shown in the following drawing. Themodelcode is followed by a test number (example: J1.1).After the test number, 12:00 PM and the words“PRESENT TIME” begin to flash in the display.

NOTE: If -- -- -- -- is flashing in the display, press theUP (↑) keypad (FIG. 7) until S525 shows, as neededfor your model. Be sure to set the correct code.Then, press the SELECT keypad to display theflashing 12:00 PM. If other thanS525 shows,whenthe transformer is first plugged in, please see page21 to reset.

SOUND “BEEPER”: A “beeper” sounds whilepressing keypads for timer set-up. One beep signals

a change in the face plate display. Repeated beepsmeans the timer will not accept a change from thekeypad you have pressed, telling you to use anotherkeypad. For example, in setting the hardness (step2), the beeper sounds repeatedly when the displayreaches 1 using the DOWN keypad, or the highesthardness setting using the UP keypad.

1. SET PRESENT TIME OF DAY:NOTE: If the words PRESENT TIME do not show inthe display, press the SELECT keypad (FIG. 7) untilthey do.

Press the (↑) UP/DOWN (↓) keypads to set the pres-ent time. PressUP tomove the display ahead; pressDOWN to move the time backward.

If the present time is be-tween noon and midnight,be sure PM shows.

If the present time is be-tween midnight and noon,be sure AM shows.

NOTE: Each press of the UP or DOWN keypadschanges the time by oneminute. Pressing and hold-ing the keypads changes the time 32 minutes eachsecond.

13

ECOWATERS Y S T E M S Programming the Electronic Demand Timer

2. SET WATER HARDNESS NUMBER:

Press the SELECT keypad once to display 25 (flash-ing) and HARDNESS.

Set the grains per gallonhardness of your water sup-ply (determined by wateranalysis or call your localwater department).

NOTE: If your water supply contains iron, compen-sate for it by adding to the water hardness number.For example, assume your water is 15 gpg hard andcontains 2 ppm iron. Add 5 to the hardness numberfor each 1 ppm of iron. In this example, you woulduse 25 for your hardness number.

15 gpg hardness2 ppm iron x 5 = 10 +10

(times) 25 HARDNESS NUMBER

Press the (↑) UP/DOWN (↓) keypads to set your wa-ter hardness number in the display. The DOWNkey-pad moves the display to 1. The UP keypad movesthe display to the highest setting (see maximum set-ting for your model in the specifications).

NOTE: Each press of the UP/DOWN keypadchanges the display by 1 between 1 and 25. Be-tween 25 and the highest number, the displaychanges 5 at a time 25, 30, 35, etc. Continuouspres-sure on the UP or DOWN keypad changes the dis-play twice each second.

NOTE: If using potassium chloride (KCl) instead ofstandard sodiumchloride (NaCl) water softener salt,hardness setting must be increased by 25%.

3. SET RECHARGE (REGENERATION) TIME:

Press the SELECT keypad once to display 2:00 AM(flashing) and RECHARGE TIME.

At the 2:00 AM RE-CHARGE TIME setting, thesoftener begins regenera-tion at 2:00 AM. This is agood time in most house-holds because water is not being used.

If a different RECHARGETIME settingwould bebet-ter for your household, do the following.

Press the (↑) UP/DOWN (↓) keypads to set the de-sired RECHARGE starting hour. Be sure to observethe AM-PM as you did when setting the time of day.

NOTE: Each press of the UP/DOWN keypadschanges the display 1 hour. Continuous pressure onthe UP or DOWN keypad changes the display twiceeach second.

4. SET EFFICIENCY, BACKWASH TIME ANDRINSE TIME:

Press and hold the SELECTbutton. “000----’” shouldshow in display. Press SELECT button once moreto go to Efficiency screen.

Press the UP or DOWN button to set the efficiencysetting either on or off.

NOTE:When efficiency set-ting is set to on, an icon willshow in the upper righthand corner of the display.

Press the SELECT button once to go to the back-wash time setting.

NOTE: Factory default forthis setting is 7 minutes.

Press theUP orDOWNbut-ton to set the desired back-wash time.

Press the SELECT button once to go to the rinsetime setting.

NOTE: Factory default forthis setting is 3 minutes.

Press theUP orDOWNbut-ton to set the desired rinsetime.

Press the SELECT keypad once again, to returnthe present time (steady) of day.

14

ECOWATERS Y S T E M S Electronic Demand Timer Features & Options

EXTRA RECHARGE

Sometimes, a manually started regeneration (re-charge) may be desired, or needed. Two examplesare:

---- You have used more water than usual (guestsvisiting) and youmay run out of soft water before thenext timer started regeneration.

---- You did not refill the softener with salt before itwas gone.

You can start a regeneration right away, or you canset the timer to regenerate at the next 2:00 AM (orother preset recharge time). Do the following.

RECHARGE NOW

Press the RECHARGE keypad and hold for 3 se-conds. RECHARGE NOWbegins to flash in the dis-play, and the softener enters the fill cycle of regen-eration right away. This regeneration will last forabout 2 hours. Then, you will have soft water again.

RECHARGE TONIGHTPress and release (do not hold) the RECHARGEkeypad. RECHARGE TONIGHT flashes in the dis-play, and the softener begins regeneration at thenext preset recharge time. If you decide to cancelthe regeneration before it has started, press and re-lease the RECHARGE keypad once more to turn offthe flashing RECHARGE TONIGHT.

PROGRAM MEMORYIf electrical power to the softener goes off, the timedisplay is blank but the face plate timer keeps thecorrect time for about 6 hours. When electrical pow-er comes on again, you have to reset the presenttime only if the display is flashing. The HARDNESSand RECHARGE TIME never require resetting un-less a change is desired.Even if the timer is incorrect after a long power out-age, the softener works as it should to keep yourwa-ter soft. However, regenerations may occur at thewrong time of day until you reset the timer to the cor-rect time of day.ERROR CODEAn error code could appear in the face plate displayif a problem occurs in the softener electronics. If yousee an error code instead of the time of day, seepage 20.

15

ECOWATERS Y S T E M S Electronic Demand Timer Features & Options

WATER METER:The water meter, consisting of a turbine, turbinemounting assembly, and the sensor housing, is lo-cated at the valve outlet port. As water passesthrough and spins the turbine, two magnets (in theturbine) cause a back--and--forth movement of aswitch in the sensor housing. This switch movementsends a pulse to the electronic demand timer.ELECTRONIC DEMAND TIMER:The demand timer is actually a small computer. Asit receives pulses from the water meter, it convertsthem to gallons of water passing through the watersoftener. It multiplies this water usage informationtimes the water hardness (preprogrammed into tim-er) to continually calculate the soft water capacity re-quired. The computer adjusts daily to water usinghabits, seeking to supply soft water for the longesttime, using the least (and most efficient) amount ofsalt and water to regenerate.When the computer determines more capacity isneeded, at the next regeneration starting time (2:00a.m., or as otherwise preset), it will schedule a re-generation.

WIRING SCHEMATIC

TRANSFORMER

120V

POSITIONSWITCH

VALVEMOTORgrnbrn

BACK OF FACEPLATETIMER

WATER METERSENSOR HOUSING

24V

A

"

16

ECOWATERS Y S T E M S How the Water Softener Works

8

Figure 8

13.

25

10):

Figure 9

9

VALVE CAM

ROTOR & DISC

17

ECOWATERS Y S T E M S How the Water Softener Works

Figure 10

11):

12

FLOW PLUGFigure 11

Figure 12

18

ECOWATERS Y S T E M S Service Information

REFILLING WITH SALT

Remove the brine tank cover and check the salt stor-age level frequently. If the unit uses all the salt beforeyou refill it, you will get hard water. Until you haveestablished a refilling routine, check the salt every 2or 3 weeks. ALWAYS refill if less than 1/2 full. Besure the brinewell cover is on.

RECOMMENDEDSALT:Cube, pellet, coarse solar,etc., water conditioner salt is recommended. Thistype of salt is from high purity evaporated crystals,sometimes formed, or compressed, into briquets. Ithas less than 1% insoluble (will not dissolve inwater)impurities. Clean, high grade rock salts are accept-able, but may require frequent brine tank cleaning toremove the ‘‘sludge’’ residue (insolubles). NOTE: Ifusing potassium chloride (KCl) instead of standardsodium chloride (NaCl) water softener salt, hard-ness setting must be increased by 25%.

SALTNOTRECOMMENDED:Rock salt, high in im-purities, block, granulated, table, ice melting, icecream making salts, etc., are not recommended.

SALT WITH IRON REMOVING ADDITIVES: Somesalts have an additive to help a water conditionerhandle iron in a water supply. Although this additivemay help keep the resin bed clean, it may also re-lease corrosive fumes that will weaken and shortenthe life of some EcoWater System Unit parts.

BREAKING A SALT BRIDGE

Sometimes, a hard crust or salt bridge forms in thebrine tank. It is usually caused by high humidity orthe wrong kind of salt. When the salt bridges, anempty space forms between the water and the salt.Then, salt will not dissolve in the water to makebrine. Without brine, the resin bed does not regener-ate and you will have hard water.

If the storage tank is full of salt, it is hard to tell if youhave a salt bridge. Salt is loose on top, but the bridgeis under it. Take a broom handle, or like tool, andpush it straight down into the salt. If a hard object isfelt, it’s most likely a salt bridge. Carefully push intothe bridge in several places to break it.

NOTE: In humid areas, it is best to keep the salt stor-age level lower, and to refill more often.

CLEANING THE NOZZLE AND VENTURI

A clean nozzle and venturi (FIG. 13) is a must for theEcoWater System Unit to work right. This small unitcreates the suction to move brine from the brinetank, into the resin tank. If it should become pluggedwith sand, silt, dirt, etc., the EcoWater System Unitwill not work, and you will get hard water.

To get to the nozzle and venturi, remove the EcoWa-ter SystemUnit top cover.Be sure the unit is in ser-vice cycle (no water pressure at nozzle and ventu-ri). Then, holding the nozzle and venturi housingwith one hand, turn off the cap. Do not lose the o--ring seal. Lift out the screen support and screen.Then, remove the nozzle and venturi. Wash theparts in warm, soapy water and rinse in fresh water.If needed, use a small brush to remove iron or dirt.Be careful not to scratch, misshape, etc., surfaces ofthe nozzle and venturi. Also, check and clean thegasket and flow plug(s) if dirty.

Carefully replace all parts in the correct order. Lubri-cate the o--ring seal with silicone grease and locatein position. Install and tighten the cap,by handonly.Do not overtighten and break the cap or housing.

Figure 13

19

ECOWATERS Y S T E M S Service Information

RESIN BED CLEANING

If the water supply contains ‘‘clear water ’’ iron (seepage 13), regular resin bed cleaning is needed tokeep the bed from coating with iron. Use resin bedcleaner, available from EcoWater, following direc-tions on the container. Clean the resin every 6months, or more often if iron appears in your condi-tioned water supply.

ADDING RESIN

Normally, the resin bed (FIG. 14) will last the lifetimeof the EcoWater System Unit. However, certainconditionsmay require partial or total replacement ofthe resin bed. Some of these conditions are:

(1) damaged top and/or bottom distributors have al-lowed resin to escape(2) resin bed iron fouled beyond use(3) some water supplies cause resin degradation

MODELNUMBER

RESIN TANKSIZE

FREEBOARDRANGE

LBS. RESIN PERINCH BED DEPTH

ESD 525 10 x 35” 8” -- 10” 2.2

FREEBOARD

resinbed

resintank

bottomdistributor

tube

add resinplug distributor tubewhile adding resin

Figure 14

IMPORTANT NOTES:Turn off the water supply and relieve pressure...seebelow.Handle the resin tank carefully. It is heavywhen filledwith resin and water.Do not lose o--ring seals or other small parts.Refer to the assembly instructions and to installationsteps to reassemble and restart the unit.

3 -- Valve Bypass

OUTLETVALVE

INLETVALVE

BYPASSVALVE

water

flow

to conditionerfrom conditioner

D for SERVICE:-- Open the inlet and outlet valves.-- Close the bypass valve.

D for BYPASS:-- Close the inlet and outlet valves.-- Open the bypass valve.

EcoWater Bypass ValveCAUTION: ALWAYS relieve water pressure in the EcoWater System Unit,as follows, before removing parts from the valve or resin tank.

DE--PRESSURIZE1. Put bypass valve(s) in bypass position.2. Do Manual Advance step1, page 23, (fill water to brine tank will depressurize the resintank).PRESSURIZE1. Put bypass valve(s) in service position.2. Do Manual Advance steps 2--5, page 23, to return unit to service.

ALTERNATE METHOD3--VALVE BYPASS ECOWATER BYPASS VALVE

DE--PRESSURIZE1. Close the INLET valve.2. Open HOT and COLD conditioned waterhouse faucets.3. Close the OUTLET valve and open theBYPASS valve.4. Close all house faucets.

PRESSURIZE1. Open HOT and COLD house faucets.2. Close the BYPASS valve and open theOUTLET valve.3. Slowly, open the INLET valve.4. Close all house faucets

DE--PRESSURIZE1.Close the house main water supply valve.2.Open HOT and COLD conditionedwaterfaucets.3. Push or rotate the bypass valve handle tobypass position.

Note: For hard water bypass to house fau-cets, reopen the main water supply valve.

PRESSURIZE1. Open HOT and COLD house faucets(main water supply valve open).2. Pull or rotate the bypass valve handle toservice position.3. Close all house faucets.

20

ECOWATERS Y S T E M S Service Information

TROUBLESHOOTING

ALWAYS MAKE THE INITIAL CHECKS FIRSTINITIAL CHECKS:1. Does the time display show the correct time ofday?...If display is blank, check power source to the Eco-Water System Unit....If time is flashing, power was off for over two days.The unit resumes normal operation, when power re-turns, but regenerations occur at the wrong time....If an error code shows in the display (example:Err03), go to AUTOMATIC ELECTRONIC DIAG-NOSTICS, below.2. Plumbing bypass valve(s) must be in serviceposition (all the way open or closed, as applies).3. Inlet and outlet pipesmust connect to the EcoWa-ter System Unit inlet and outlet respectively.4. Is the transformer plugged into a ‘‘live’’, groundedwall outlet, and the power cable fastened securely?5. The valve drain hose must be free of kinks andsharp bends, and not elevated over 8’ above thefloor.6. Is there salt in the brine tank?7. Is the brine tubing connected? See repair partspage 26.8. Press the SELECT keypad two times to displaythe hardness setting. Be sure it is the correct setting

for the household’s water supply. ---- Make a hard-ness test of the raw water and compare with thehardness setting. Also test a conditionedwater sam-ple to verify if a problem exists. ----Press SELECTtwice more to return the present time display.If you do not find a problem after making the initialchecks, do MANUAL INITIATED ELECTRONICDIAGNOSTICS, and the MANUAL ADVANCE RE-GENERATION CHECK.

AUTOMATIC ELECTRONIC DIAGNOSTICS

The faceplate computer has a self--diagnostic func-tion for the electrical system (except input powerandwater meter). The computer monitors electroniccomponents and circuits for correct operation. If amalfunction occurs, an error code appears in thefaceplate display.

The chart below shows the error codes that couldappear, and the possible defects for each code.

While an error code appears in the display, all face-plate keypads are inoperable except the SELECTkeypad.SELECT remains operational so the serviceperson can make the MANUAL INITIATED ELEC-TRONIC DIAGNOSTICS to further isolate the de-fect, and check the water meter.

POSSIBLE DEFECT

CODE MOST LIKELY '--------------------------------------------------------------------' LEAST LIKELY

Err 01 Err 02Err 03 Err 04

wiring harness or connection to position switch / switch / valve defect causing high torque / mo-tor inoperative

Err 05 faceplate

PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:1. Unplug transformer-------- 2. Correct de-fect-------- 3. Plug in transformer-------- 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

21

ECOWATERS Y S T E M S Service Information

CHECKINGTHEMODEL CODEENTRY (See page12)

Unplug the transformer at the electrical outlet, thenplug it in again. A “beep” will sound, then the modelcode displays for a few seconds. The test numberwill then display for a few seconds, followed by thepresent time display.

CHANGING THE MODEL CODE

IMPORTANT: READ page 12 BEFORECHANGINGTHIS CODE.

1. Enter the secondary mode...press SELECT andhold for 3 seconds.

2. Again, press SELECT and hold for 3 seconds.The current model code setting will display.

3. Use the (↑) or (↓) keypad to display the desiredmodel code.

4. Press SELECT to set.

5. Reset the timer (page 12) and reselect other de-sired options.

MANUAL INITIATED ELECTRONIC DIAGNOSTICS

1. To enter diagnostics, press the SELECT keypadand hold for 3 seconds.

A.The first 3 digits indicate watermeter operation asfollows.

000 (steady) = conditionedwater not in use...no flowthrough the meter.

--open a nearby CONDITIONED WATER faucet--

000 to 199 (continual) = repeats display for each gallon of water passing through

the meter.

If you don’t get a reading in the display, with a faucetopen, pull the sensor housing from the valve outletport. Pass a small magnet back and forth in front ofthe sensor. You should get a reading. If you do geta reading, disconnect the outlet plumbing andcheck the turbine for binding. If you don’t get areading, the sensor is probably defective. CAU-TION: BE SURE TO TURN OFF WATER BEFOREYOU DISCONNECT PLUMBING.

Use the RECHARGE keypad to manually advancethe valve into each cycle and check correct switchoperation (step B ), and observe the valve positionindicator bars (step C).

B. The letter (P) and dash or dashes indicate posi-tion switch operation. The letter shows if the switchis closed. A dash shows when the switch is open.

NOTE:Theposition switch is closedwhen theplung-er is depressed, open when extended.

CORRECTSWITCHDISPLAYS

VALVE CYCLE STATUS

-- -- valve in service, fill, brining, back-wash or fast rinse position

-- P valve rotating from one position toanother

22

ECOWATERS Y S T E M S Service Information

C. While in this diagnostic screen, the following in-formation is available andmay be beneficial for vari-ous reasons. This information is retained by thecomputer from the first time electrical power is ap-plied to the face plate.

---- Press (↑) to display the number of days this faceplate has had electrical power applied.

---- Press (↓) to display the number of regenerationsinitiated by this face plate since themodel codenum-ber was entered.

3. Press the SELECT keypad and hold 3 secondsuntil...

S525 shows.

This code identifies the softener nominal capacitysize. If the wrong number shows, the softener willoperate on incorrect programming. Do the followingas needed.

Return the present time display: Press the SE-LECT keypad.

Change the model code number: To display thecorrect model code number, press the (↑) UP orDOWN (↓) keypad. Press SELECT, and reset thetimer.

NOTE:

If the face plate is left in a diagnostic display (or aflashing display when setting times or hardness),present time automatically returns if a keypad isnot pressed within 4 minutes.

FACE PLATE REPLACEMENT: Be sure thevalve is in service position (observe valvecycle indicator) when replacing the face plate.

If, after installing and programming the replace-ment face plate, the valve is not in service posi-tion, do the following to assure correct cycleorientation, or timing, between the face plate andvalve.

Use the MANUAL ADVANCE procedures, page23. With the RECHARGE keypad, advancethrough the recharge cycles until the valve stopsin service position, and RECHARGE no longerflashes in the timer.

NOTE: The valve motor may automatically drivethrough several valve positions while searchingfor service. If an error code occurs, unplug thetransformer, then plug in again.

CAM MOTOR

positionmarkers(valve inservice)

23

ECOWATERS Y S T E M S Service Information

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valvemo-tor, brine tank fill, brine draw, regeneration flowrates, and other controller functions. Always makethe initial checks, and the manual initiated diag-nostics.

NOTE: The face plate display must show a steadytime (not flashing).

1. Press the RECHARGE keypad and hold in for 3seconds. RECHARGE NOW begins to flash as thesoftener enters the fill cycle of regeneration. Re-move the brinewell cover and, using a flashlight, ob-serve fill water entering the tank.

a. If itdoes notenter the tank, look for an obstructednozzle, venturi, fill flow plug, brine tubing, or brinevalve riser pipe.

2. After observing fill, press the RECHARGE key-pad to move the softener into brining. A slow flow ofwater to the drain will begin. Verify brine draw fromthe brine tank by shining a flashlight into the brine-well and observing a noticeable drop in the liquid lev-el.

NOTE: Be sure a salt bridge is not preventing waterwith salt contact.

a. If the softener does not draw brine:-- nozzle and/or venturi dirty or defective.-- nozzle and venturi not seated properly on gasket.-- restricted drain (check drain fitting and hose).-- defective nozzle and venturi seal.-- other inner valve defect (rotor seal, rotor &disc, wave washer, etc.).

NOTE: If water system pressure is low, an elevateddrain hosemay cause back pressure, stopping brinedraw.

3. Again press RECHARGE to move the softenerinto backwash. Look for a fast flow of water from thedrain hose.

An obstructed flow indicates a plugged top distribu-tor, backwash flow plug, or drain hose.

4. Press RECHARGE to move the softener into fastrinse. Again look for a fast drain flow. Allow the soft-ener to rinse for a few minutes to flush out any brinethat may remain in the resin tank from the briningcycle test.

5. To return the softener to service, press RE-CHARGE once more.

24

ECOWATERS Y S T E M S Service Information

Before working on the valve, turn off the water sup-ply and disconnect from electrical power.

TO RELIEVE PRESSURE

-- 3 VALVE BYPASS: Close the inlet valve and opena soft water faucet. Then close the outlet valve andopen the bypass valve.

-- OPTIONAL BYPASS:Slide the bypass valve stemto bypass position. Loosen the 3 hex head screws(see A in drawing) toward the backside of the valveto allowpressure water to bleed out. Catch thewaterwith a rag.

DISASSEMBLY

To remove a part or group of parts, refer to the valvedrawing. A common screwdriver or nut driver, Phil-lips screwdriver and pliers are the only tools neededto completely disassemble.

SERVICING THE VALVE

Inspect all o-rings, seals and gaskets for wear or de-fects.

Inspect the bottom surface of the rotor and disc forscratches, chips or wear.

NOTE: If replacement is needed, be sure to use thecurrent replacement part.

ASSEMBLY

Be sure all parts are in place and in the proper posi-tion. Lubricate ALL o-rings and seals with FDA ap-proved silicone grease. To install the rotor seal, firstplace the seal into the valve groove, rounded sidedown (see cross-section). Apply a light coating of sil-icone grease to the seal’s crossing ribs. Then, care-fully center the wear strip on the seal, and push itdownward onto the seal.

Install the nozzle and venturi seal and drain seal. As-semble two o-ringsand thewavewasheronto the ro-tor and disc. Then center the rotor and disc, in thevalve body, on the rotor seal.

Lower the cover onto the valve body and rotor shaft.Then install the cover holding screws. Before tight-ening the screws, install the valve cam and gear.Then, turn the rotor (CLOCKWISEONLY) to SER-VICE position. Tighten the screws using a criss-cross pattern. If a torque wrench is available, torqueto 30-40 inch pounds. Lubricate the gear on the mo-tor, and the valve cam gear with Molykote grease, orother high quality gear lubricant. Be sure to orientthe switch as shown, with the lever toward the cam.

motor

switchmotor plate

cam & gear

o-ring seals

wave washer

rotor & disc

o- ring

rotor seal

drain seal

see Nozzle assemblyservice, page 18

nozzle & venturi seal

seal

wear--strip

A

25

ECOWATERS Y S T E M S Service Information

ESD 525RATED CAPACITY (grains @ salt dose) 15,900 @ 3.1 lbs

27,900 @ 8.8 lbs33,000 @ 14.4 lbs

RATED EFFICIENCY (grains / lb of salt @ min. salt dose) 5,100 @ 3.1 lbs

PRESSURE DROP AT SERVICE FLOW RATE (psi) 7

SERVICE FLOW RATE (GPM) 6

INTERMITTENT FLOW RATE @ 15 PSI (gpm)¡ 9.0

INTERMITTENT FLOW RATE @ 30 PSI (gpm)¡ 13.4

MIN.--MAX. WORKING PRESSURE (PSIG) 20 -- 100

MIN.--MAX. OPERATING TEMPERATURE (_ F) 40 -- 120

FILL CYCLE MINUTES ©

FLOW (GPM) 0.3

BRINING AND BRINE RINSECYCLE

MINUTES 102 -- 104CYCLE

BRINING FLOW (GPM) .22

BR. RNS. FLOW (GPM) .15

BACKWASH CYCLE MINUTES 7

MAX. FLOW (GPM) 2.0

FAST RINSE CYCLE MINUTES 3

MAX. FLOW (GPM) 2.0

HiGH CAPACITY RESIN LOAD POUNDS 47

CUBIC FEET .9

SALT STORAGE CAPACITY -- POUNDS 200

¡ Intermittent flow rate does not represent the maximum service flow rate used for determining the softenersrated capacity and efficiency. Continuous operation at flow rates greater than the service flow rate may affectcapacity and efficiency performance. The validity of these flow rates is verified by NSF.

© Fill time is automatically determined by the timer, depending upon the capacity operating level.

This system conforms to NSF/ANSI 44 for the specific performance claims as verified and substantiated bytest data. The efficiency rating is only valid at the stated salt dosage. This softenerwasefficiency rated accord-ing to NSF/ANSI Standard 44.

26

ECOWATERS Y S T E M S Repair Parts

11

12

6

7

25

26

27

2829

30

31

89

10

18

13

14

23

22

20

17

1615

32

12

3

5

Valve Assembly(see page 28)

2421

4

19

33

27

ECOWATERS Y S T E M S Repair Parts

KEYNO.

PARTNO. DESCRIPTION

1 7275907 Transformer, 24V--10VA

2 7218662 Top Cover

3 7210509 Faceplate (order following decal)

-- 7287409 Decal

4 7285782 Repl. PWA

5 7211173 Faceplate Support

6 7170296 O--ring Seal, 2--7/8” x 3--1/4”

7 7170254 O--ring, 13/16” x 1--1/16”

8 7077870 Top Distributor

9 7170270 O--ring, 2--3/4” x 3”

10 7105047 Repl. Distributor (bottom)

11 7176292 Clamp Section, 2 req.

12 7088033 Clamp Retainer, 2 req.

13 7113066 Resin Tank, 10” dia. x 35”

14 0502272 Resin, 1 cu ft (stand. mesh)

15 1103200 Hose Adaptor

16 9003500 Grommet

-- 0900431 Hose Clamp (not shown)

17 7218604 Brine Tank

18 7287386 Rim

KEYNO.

PARTNO. DESCRIPTION

19 7214244 Vapor Barrier

20 7273997 Salt Hole Cover

21 7219587 Screw

22 7109871 Brinewell

23 7155115 Brinewell Cover

24 7219595 Washer

25 7221754 Float, Stem and Guide Assembly

26 7170288 O--ring, 15/16” x 1--3/16”

27 1205500 Clip

28 7092252 Brine Valve Body

29 7080653 Clip

30 7131365 Screen

31 7113016 Tubing Assembly, BV

32 7221746 Brine Tube

33 7129871 Bypass Valve

J 7220928 Brine Valve Assembly (incl. key nos. 25through 32)

J 7108118 Hose, 1/2” I.D. Drain (order lengthneeded)

optional part.

J not illustrated.

28

ECOWATERS Y S T E M S Repair Parts

50

1

2

4

3

5

6

7

8

9101112

13

14

15

16

17

2120

19 18

23

43

28

27

32

30

29

31

33

34

35

36

37

39

40

41

42

45

46

47

48

24

cross--sectionview

seal

wear--strip

25

26

49

22

44

38

29

ECOWATERS Y S T E M S Repair Parts

KEYNO.

PARTNO. DESCRIPTION

1 7224087 Screw, #8-32 x 1” (2 req.)

2 7286039 Motor (incl. 2 ea. of Key No. 1)

3 0900857 Screw, #6-20 x 3/8 (2 req.)

4 7231385 Motor Plate

5 0503288 Bearing

6 7284964 Cam and Gear

7 7142942 Clip (Drain)

8 0900431 Tubing Clamp

9 7024160 Drain Hose Adaptor

10 7170327 O-Ring, 5/8 x 13/16

11 0501228 Flow Plug

12 7170238 O-Ring, 7/16 x 5/8

13 7170212 O-Ring, 3/4 x 15/16

14 7082087 Wave Washer

15 7199232 Rotor & Disc

16 7170246 O-Ring, 3---3/8 x 3-5/8

17 7116713 Clip (2 req.)

18 0507369 Installation Nut (2 req.)

19 0507615 Installation Tube (2 req.)

20 7170335 Washer (2 req.)

21 2207800 Installation Adaptor (2 req.)(incl. 2 ea. of Key No. 22)

22 7170288 O-Ring, 15/16 x 1-3/16 (2 req.)

23 7134224 Rotor Seal

24 7170204 O-Ring, 3/8 x 9/16

25 7092642 Plug (Drain Seal)

26 7129889 Spring

27 2204101 Turbine Support and Shaft

28 7117858 Turbine

29 7082053 Valve Body

KEYNO.

PARTNO. DESCRIPTION

30 7081764 Seal (Nozzle & Venturi)

31 7170319 O-Ring, 1/4 x 3/8 (2 req.)

32 7081201 Retainer (Nozzle & Venturi)

33 7081104 Nozzle & Venturi Housing

34 1202600 Nut - Ferrule

35 7095030 Cone Screen

36 1148800 Flow Plug, .3 gpm

37 7114533 Nozzle & Venturi Gasket Kit

-- 7204362 Gasket (only)

38 7084607 Flow Plug, .15 gpm

39 7146043 Screen

40 7167659 Screen Support

41 7170262 O-Ring, 1---1/8” x 1---3/8”

42 7199729 Cap1

43 7309803 Sensor Housing & Wiring Asm

44 7085263 Valve Cover

45 7074123 Screw, #10-14 x 2 (5 req.)

46 7077472 Expansion Pin

47 7030713 Switch

48 7117816 Spacer

49 7070412 Screw, #4-24 x 1-1/8 (flat head)

50 7248706 Ground Clamp Kit

z 7253808 Nozzle & Venturi Assy. (incl. Key Nos. 33,and 35 through 42)

z 7129716 Seal Kit (incl. Key Nos. 12, 13, 23, 24 &30)

z not illustrated

30

ECOWATERS Y S T E M S Guarantee Bond

GUARANTEE BONDThe Safeco Insurance Company of America has issued it’s bond in the form shown below, guaranteeing fullperformance by EcoWater Systems LLC.

SAFECO INSURANCECOMPANYOFAMERICA, hereinafter called ‘‘Surety,’’ guarantees untoBank of NewYork as Trustee holding said Guarantee Bond under the terms of a Trust Agreement dated April 9, 2003, forthe use and benefit of original purchasers of residential EcoWater Systems Units within the ContinentalUnited States, as described herein, that EcoWater Systems LLC, will discharge the obligations of the ‘‘Eco-Water Bonded Parts and Service Guarantee Policy.’’

PROVIDED, HOWEVER, that:

1. Liability of Surety hereunder shall not exceed the sum of FIVE HUNDRED AND 00/100th DOLLARS($500.00) as to any one installation, and shall not exceed the sum of FIVE HUNDRED THOUSAND AND00/100th DOLLARS ($500,000.00) in the aggregate, and

2. There shall be no liability hereunder as to any purchaser to whom there has not been issued at the timeof installation and purchase completed registration card which is enclosed with a facsimile of this bond, andwho has not returned such card in accordance with this guarantee.

3. Claim must be made by such original purchaser in writing within 30 days from the expiration of these guar-antees uponEcoWater Systems LLC, POBox 64420, St. Paul, MN 55164, to perform the terms of said guar-antee, and notice of any default on such guarantee must be sent to Surety at its address by Registered Mail.

SAFECO INSURANCE COMPANY OF AMERICA

This is to certify that the original of the above guarantee and bond is on file with Bank of New York.

BANK OF NEW YORKAs Trustee

31

ECOWATERS Y S T E M S Warranty

LIMITED WARRANTYEcoWater Systems LLC Advantage Warranty

ESD 525 Water SystemCongratulations! You have just purchased the highest quality water conditioning product on the market. To register yourwarranty, complete the enclosed Warranty Registration Card and mail it within 30 days of purchase.To whom is this warranty extended?EcoWater Systems LLC warrants its products to the original owner and guarantees that the products will be free from de-fects in materials and workmanship from the original date of installation.How does my warranty work?If, during the respective warranty period, a part proves, after inspection by EcoWater, to be defective, EcoWater will, atits sole option repair or replace that part at no charge, other than normal shipping and installation charges.What is covered by the warranty?EcoWater systems LLC guarantees that,for the LIFETIME of the original owner, the MINERAL TANK will not rust, corrode, leak, burst, or in any other manner failto perform its proper function and that,for a period of TEN (10) YEARS after installation, the SALT TANK will be free of defects in materials and workmanshipand will perform its proper function and that,for a period of THREE (3) YEARS after installation, the VALVE BODY, ELECTRONIC FACEPLATE and ALL OTHERPARTS will be free of defects in materials and workmanship and will perform their normal functions.How do I obtain local service?Should you need service, your local, independent EcoWater Dealer is only a phone call away.PHONE:

If I need a part replaced after the factory warranty expires, is that part warranted?Yes, EcoWater Systems LLC warrants FACTORY REPAIRS as well as all replacement parts for a period of 90 DAYS.Are any additional warranties available?We are pleased to say, YES! EcoWater Systems LLC offers an EXTENDED, PARTS ONLY WARRANTY for the ELEC-TRONICS portion of your product. This warranty is called the “Perfect Ten” and extends the three year warranty on theelectronic FACEPLATE,WIRINGHARNESS, DRIVEMOTOR, TRANSFORMER, POWERCORD, SENSORHOUSING,and MICRO SWITCHES to a total of TEN YEARS from the date of original installation. Should your local dealer not offerthis warranty, you may contact the factory for additional information.*General ProvisionsThe above warranties are effective provided the water conditioner is operated at water pressures not exceeding 125 psi,and at water temperatures not exceeding 120°F; provided further that the water conditioner is not subject to abuse, mis-use, alteration, neglect, freezing, accident or negligence; and provided further that the water conditioner is not damagedas the result of any unusual force of nature such as, but not limited to, flood, hurricane, tornado or earthquake. EcoWaterSystems LLC, is excused if failure to perform its warranty obligations is the result of strikes, government regulation,materi-als shortages, or other circumstances beyond its control.To obtain warranty service, notice must be given, within thirty (30) days of the discovery of the defect, to your local EcoWa-ter Systems dealer.*THERE ARE NO WARRANTIES ON THE WATER CONDITIONER BEYOND THOSE SPECIFICALLY DESCRIBEDABOVE. ALL IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FIT-NESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE EXTENT THEY MIGHT EXTEND BEYOND THEABOVE PERIODS. THE SOLE OBLIGATION OF ECOWATER SYSTEMS LLC UNDER THESE WARRANTIES IS TOREPLACE OR REPAIR THE COMPONENT OR PARTWHICH PROVES TO BE DEFECTIVEWITHIN THE SPECIFIEDTIMEPERIOD, ANDECOWATER IS NOT LIABLE FOR CONSEQUENTIALOR INCIDENTAL DAMAGES. NOECOWA-TER DEALER, AGENT, REPRESENTATIVE, OR OTHER PERSON IS AUTHORIZED TO EXTEND OR EXPAND THEWARRANTIES EXPRESSLY DESCRIBED ABOVE.Some states do not allow limitations on how long an implied warranty lasts or exclusions or limitations of incidental or con-sequential damage, so the limitations and exclusions in this warrantymay not apply to you. This warranty gives you specif-ic legal rights, and you may have other rights which vary from state to state. This warranty applies to consumer--ownedinstallations only.