Page 1: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

ORION EM G

Page 2: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

----------------------------------------------

ELECTRONIC MEASURING INSTRUMENTS

GENERATORS ELECTRONIC VOLTMETERS AND AMMETERS DIGITAL VOLTMETERS AND FREQUENCY METERS OSCILLOSCOPES- -POWER SUPPLIES INDUSTRIAL MEASURING INSTRUMENTS

ELECTRONIC MEDICAL TEST EQUIPMENTS ELECTRONIC LOGIC CIRCUITS ELECTRONIC DeSK CALCULATORS ELECTRONIC DIGITAL COMPUTERS

This short catalogue contains a representative selection of EMG's-Works for Electronic Measuring Gear­products. Owing to the numerous types of product only a few lines of technical data are provided on each type in this catalogue. The published informations in short form facilitate the choice of the most suitable instruments for the purpose of electronic measure­ments, medical examinations, processing control, data process, as well as arithmetical operations. If you require more detailed information than that covered by this catalogue, please let us know your specific interest. From any types or any groups we gladly send you the full technical details upon your request.

For measurements, tests, calculations and control many electronic measuring inst-ruments, equipment are necessary in electronic, medical sciences, data pro­cessing as well as in a wide range of industrial appli­cations. EMG developes and manufactures instruments widely used for the above purposes. Besides a quantity of products the factory every year developes and mar­kets new instruments satisfying the most diverse requirements. Should the development of our pro­ducts or the trend of our manufacturing program require it, we reserve the right to discontinue the production of some types described here or to deliver instead of them a later design.

-

Page 3: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

ELECTRONIC MEASURING IHSTRUMEHTS•CiEHERATORS LOW-FREQUENCY GENERATORS

EMG-1117/1 TR-0<402 Low-frequency Test Waveform Generator

The Instrument is suitable for producing single and continuous signals with adjustable durations and sinusoidal, rectangular, triangular, saw-tooth and pulse waveforms. Both the duration and the output amplitude of signals can be adjusted within wide limits, by 2-digit decadic adjustment.

Adjustable signal duration: Accuracy of signal duration: Max. output level: Amplitude adjustable at the attenuated output :

Dimensions :

EMG-1118 TR-~53 Low-frequency Oscillator

1 ms to 1,000 s

±2% 150 Yp-p 10001.Y P- P to 100V P- P•

15 Yp - p to 150 Yp - p• resp. 325 x 500 x 385 mm

EMG-1117/2 TR-0403 Low-frequency Generator

The instrument is suitable for producing sinusoidal, rectangular and triangular waveform 'signals, with two phases (0° and 180°). Frequency of the signals can be adjusted in decade steps with a 3-dlgit accuracy, output voltage can be adjusted by 2-digit decadic adjustment.

Adjustable frequency : Frequency accuracy: Max. output level: Amplitude adjustable at the attenuated output at rectangular and triangular waveform voltages:

at sinusoidal voltages:

Dimensions :

0.001 cjs to 1,110 cfs ±2% 150 Yp- p

2x 10fLVp-p to 2x100 vP - P 2x1 ~-tYrms to 2x 10 Vrms 325 X 500 X 385 mm

EMG-1117/9 TR4404 Low-frequency Var-Iable Phase Unit

Connected to low-frequency generators type EMG-1117/1 or EMG-1117/2 the Low-frequency Variable Phase Unit produces a second sinusoidal voltage, with the desired phase shift related to sinusoidal output voltage of the generator.

Frequency range: Phase shift : Accuracy of phase shift : Amplitude of the output signal: Dimensions :

0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500 x 385 mm

The Instrument contains an RC oscillator and all amplifier ensuring symmetrical output. It is particularly suitable for testing medical or control equipment. L F. OSCILLATOR

Frequency range : Frequency accuracy:

Distortion factor:

Output voltage:

Dimensions:

0.1 cfs to 10 kc/s ±5% (10 cfs to 10 kc/s) ...;;3%

(20 cfs to 10 kcfs) 2x1 Vrms, symmet­rical 135x220x2<40 mm

-

e I•

e .

se

Page 4: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

O SCILLATORS A ND A F GENERAT ORS

EMG-111-4 TR-0151 Transistor ized AF O scillato r

The instrument is used for producing sinusoidal signals with very low distortion in t he audio-frequency range. It is fully transistorized and can be operated either from mains or from an external battery.

Frequency range : Frequency accuracy : Output voltage :

Distortion factor 200 cfs to 10 kcfs: Dimensions:

20 cfs to 20 kc/s

±1%±1 cjs 0 to 4 V (into 600 ohms) ~0.1%

220x 180 x 295 mm

EMG-11 H TR-0250 T ra nsistorized MF O scillator

The instrument furnishes low distortion sinusoidal signals. It is fully transistorized and can be ope rated from mains or from an external battery.

Frequency range : Frequency accuracy :

30 cjs to 550 kc/s

±3% Output voltage : 0 to 1.1 V

Distortion factor 100 cfs to 200 kc 's :

(into 600 ohms) :s O,S%

Dimensions : 220 x 180 x 295 mm

EMG-1 115 TR-0105 Au d io Frequency Gene rat o r

The RC oscillator of the instrument supplies in the range of 20 and 20,000 cfs sinusoidal AF voltages. The generator incorporates an amplifier and a voltmeter.

RC OSCILLATOR Frequency range : 20 c/s to 20 kc1s Distortion factor : ~0.3% RC OSCILLATOR WITH AF AMPLIFIER Output power : max. 5 W Optimum load at asymmetrical output : at symmetrical output :

Dimensions :

5, 600, 5,000 ohms 2x 300, 2 x 2,500 ohms 180 X 436 X 360 mm ----

EMG -1289 TR-0871 Pushbutton Decad e Generator

The instrument provides low distortion sinusoidal signal. By means of the pushbutton­system 4,500 discrete values can be selected in 5 decadic bands, with th ree significant figures in steps of 0.01 digit . The instrument is fu lly transistorized and can be operated from mains or from a built-in battery.

Frequency range : Frequency accuracy 10 c/s to 99.9 kc ls · Distortion factor 100 c is to 20 kc s Output voltages

Dimensions ·

10 c/s to 1 Mc/s ±1% 4i0.5% 0 to 2.5 V, 0.25 V. 0.025 V, resp. (Into 600 ohms) 220 x 230 x 270 mm

Page 5: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

:

SIGNAL GENERATORS

EMG -1165 TR-0550 Crystal-controlled Signal Generator

The instrument furnishes calibrated HF signals which can be used either unmodulated or amplitude modu lated. Fully transistorized .

Frequency range : Frequency accuracy : Frequency calibration:

Output voltage :

Modulation :

Dimensions :

100 kc/s to 30 Mc/s ± 1% by means of a built-in 1 Mc/s quartz oscillator 0.5 .uV to 100 mY {int~ 50 ohms) internal AM (400 or 1,000 cfs) external AM 200x260x280 mm

EMG-1168 TR-0503 Crystal-controlled Laboratory Signal Gene­rator

This is a high-accuracy signal generator operating in the 50 kcfs to 65 Mcfs frequency r ange. By means of the built-in crystal oscillator hig h accuracy of frequency calibration can be obtained. Frequency range: SO kcfs to 6S Mc/s Frequency accuracy: ± 1% Frequency calibration : by means of a built-in

quartz oscillator with 10- • accuracy

Output voltage : 0. 1 '! V to 3 V {into SO ohms)

Modulation: internal AM (400 or 1,000 cis) external AM

Dimensions: 300 X 500 X 380 mm

EMG-1173 /2 TR-0604 VHF Signal Generator {AM-FM­Video-Stereo)

The instr ument can be used in almost al l fie lds of telecommuni­cation engineering where in the frequency range of 4 to 300 Mc/s an AM, FM, video-, stereo-, or pulse modulated highly accurate H F signal source is needed. Frequency range: Freq uency accuracy : Output vo ltage :

Modulation·

Dimensions :

4 to 300 Mc fs ± 1% 0.5 iJ.V to 100 mV. 0.5 iJ.V to 1 V, resp. internal. exte r nal AM, internal , external FM , video, stereo, pu lse 317 X S70 X 340 mm

EM G-11 75 /2 TR-0602 UHF Signal Generator

Owing to its wide modu lation and other control faci li ties, the instrument can be used for perform ing a variety of UH F mea­surements.

Frequency range : Frequency accuracy : Output voltage :

Modulation:

Dimensions :

250 to 1,000 Mcfs ± 1% O.S iJ.V to 100 mV, 0.5 (J.V to 4 V, resp. inter nal square wave , internal, external AM. internal. external FM, external video, pulse 330 x 580 x 380 mm

Page 6: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-1176/B TZA-101-B

EMG-1177 TZA-102

~ .. -_ ... (J Q) ..... ...........

~ --

g ~ -

~

EMG-1178 TZA-103 Microwave Signal Gener· a tors

The instruments are suitable for all low-power microwave measurements.

Frequency range EMG-1176/ B: EMG-1177 : EMG-1178 : Frequency accuracy: Output power:

Modulation:

Dimensions :

1,800 to ~.000 Mcfs 3,800 to 7,500 Mcfs 7,000 to 10,500 Mcfs

± 1% min. 1 mW (50 ohms) internal, external pulse, internal, external FM, internal square wave 400x610x330 mm

• ...... - ••

EMG-1175/ 3 TR-0603 UHF Signal Gener:ator

Owing to Its wide modulation and other control facil ities the instrument can be used fo r performing a variety of UHF measurements.

Frequency range: Frequency accuracy : Output power:

Modul~tion :

Dimensions :

1,000 to 2,500 Mcfs

±1% min. 1 mW (50 ohms) internal, external pulse, internal, external FM, internal square wave 400 X 500 x 380 mm

EMG-1274 TR-0610 UHF Power Generator

The instrument is suitable for producing calibrated high­level signals in the ultra-high frequency range of 250 to 1,000 Mcfs.

Frequency range : Frequency accu racy : Max. output power:

Modulation:

Dimensions :

250 to 1,000 Mc/s

±1% min. 2 W (50 ohms) internal square wave, external pulse 320 x 570x390 mm

Page 7: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

CO!-OR TV GENERATORS

EMG-1265 TR-0869 Color TV Tester

The instrument is suitable for testing SECAM sets, its test signals have been designed accordingly : color purity and convergence signals serving for the adjustment of color picture tube, gray scale signal, testing signals serving for the measurement of color demodulator and identifying circuit. The instrument provides also signals on the VHF carrier frequency according to the OIRT channel I, in the required high level, supplemented with 1 kc/s AF modulation, for testing of the sound channel. Fully tran­sistorized.

Dimensions: 90x400x350 mm

·~ .. .. ..

~:P ~!"' -·--

MODULATION METER

EMG-1651 TR-5401 AM-FM Modulation Meter

The instrument is suitable for control measurements needed wi t h AM and FM systems operating in the 4 to 1,000 Mc/s frequency range.

Carrier frequency range : with harmonic mixing: MEASUREMENT OF AM

4 to 250 Mc/s 250 to 1,000 Mc/s

Measuring ranges of modulation percentage : 5, 15, 50, 100% Accuracy of modulation percentage measurement : MEASUREMENT OF FM Measuring ranges of FM deviation measurement:

Accuracy of FM deviation measurement ; Dimensions :

±3%

0.5; 1.5; 5; 15; 50;

150 kc/s

±2% 300 X SOD X 380 mm

• COlOR TV TESTSI

~ ""' -.. - • :=: ·-· ·• · L I ... - () • 8 ! --..

EMG-1266 TR-0870 Laboratory Color TV Gener­ator

The instrument serves for perfor·ming measure­ments and adjustments on SECAM TV sets. It consists of the video, synchron and oscillator­modulator un its. Since it furnishes signals with studio quality, it can be used primarily for labora­tory measurements. The video unit provides video signals ; luminence signal, color scale signal, color identification signal, R.G.B. base signals, conver­gence signals produced from e ither an ex ternal signal source or internal signals. The synchron unit provides OIRT synchron and blanking signals. The oscillator-modulator unit furnishes VHF, UHF signals.

Dimensions : 222 X 435 x 400 mm

Page 8: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

PRECISION SWEEP GENERATOR

EMG-1 294 TR-0904 " SWEEPOSCOPE" Precision Sweep Generator

The SWEEPOSCOPE is a comb ined instr ument serving for the calibration of active and passive two- and fou r-pole networks within the frequency range of 0.5 to 1,000 Mc{s. It comprises a transm itter, receiver and ind icator un it. The

transmitter unit is a high-stability sweep generator. It supplies H F signals with continuously adjustable deviation . Sweep frequency is SO cfs. The rece iver un it contains d iode detectors

for the measurement of t he input and output signals of the object to be tested . The signals can be plotted on t he 36 em screen of the television picture-tube of an oscilloscope.

Dimensions : 440 x 580 x 400 mm

BROADCAST TRANSMITTER TEST ASSEMBLY

EM G-1189 TR-5601 Broa dcast Transmitter Test Assembly

The equipment is suitable for making measurements of every essent ial qualitative and technical parameter of the radio broadcast t r ansmitter. The following measu re ments

can be performed : harmon ic distortion (0 to 10%. with ±0.5% accuracy); modulation

depth (0 to 100% . wit h ±5% accuracy): frequency deviation (0 to 75 kc/s. with ±5% accuracy) ; frequency response (in AM o r FM modes of operation, with ± 1 dB accuracy). noise leve l (up to - 56 dB): stability of the ent ire t ransmission channel (with ± 1 dB accuracy). By means of these measurements t he equ ipment facilitates a continuous monit oring of broadcast ing quality. The equ ipment consists of 13 plug-in units , which

are the following : logo mete rs (2 pc) ; FM receive rs (2 pc): deviation meters (2 pc) ; AM receiver: oscilloscope: AF generator ; AM modulation meter and monitor line selector: automatic distortion, frequency response and noise level meter; swit ch,ng

unit and sound monitor ing unit.

Dimensions: 2.000 x 600 x 500 m m

Page 9: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

PULSE GENERATORS

EMG-1153 TR-0353 Pulse Generator

The instrument is a fully transistorized, small-size pulse generator. The pulse repetition rate, pulse width and delay can be regulated within -------::::::~;::.;;;:;~

very wide limits. The amplitude of pulses of both polarities generated simultaneously can be adjusred separately.

Pulse repetition rate : 10 c{s to 2 Mc/s External tr iggering and single triggering facility provided Pulse delay : 100 ns to 10 ms Pulse width : Amplitude :

Polarity :

Rise and fall time : Dimens ions :

100 ns co 10 ms max. 10 V (into 50 ohms) positive and negative , sim ultaneously .... 20 ns 92 x 325x298 mm

EMG-1155 TR-0304 Pulse, Double Pulse and Square Wave Generator

The instrument is a versatile pulse generator, most suitable for workshop measurements. The pulse repetition rate, pulse width and delay and the amplitude of pulses of both polarities generated simultaneously can be adjusted separately.

Pulse repetition rate : External t r iggering and Pulse width : Pulse delay :

c/s to 1 Mc/s single t riggering faci lity provided

200 ns to 2 ms 200 ns to 2 ms

Pulse delay in double pulse mode of operation : Amplitude Z> 50 ohms output: 50 ohms output: Rise and fall time : Polarity:

Dimensions:

-400 ns to 2 ms

2 V to 50 V

2 mY to 2 V 25 ns positive and negative, simultaneously 265x500 x 3BO mm

EMG-115"1 TR-0302 Laboratory Pulse, Double Pulse an d Square Wave Generator

The instrument is a pulse generator suitable for laboratory measurements, in a wide field of applications. The repe­tit ion rate, pulse width, delay and amplitude of pulses of both polarities generated simultaneously can be adjusted separately.

Pulse repet ition rate : 0.1 c/s to 1 Mc/s Externa I triggering and single triggering facility provided Pulse width: 100 ns to 11 ms Pulse delay: 100 ns to 11 ms Pulse delay in double pulse mode of operation : Amplitude Z > 50 ohms output: 50 ohms output : Rise and fall time : Polarity:

Dimensions:

200 ns to 11 ms

10 V to 50 V 2 mV to 10 V 25 ns positive und negat ive, simultaneously 445 X 500 X 380 mm

Page 10: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

The plug- in un its may be placed into a cabinet of rack-system. Each cabinet is capable of accommoda'ting 6 units. The units may be interconnected through coaxial terminals located on their front or rear panels. More rack cabinets might be fitted together as well, thus the number of the modul units can be extended at will.

Pulse repet ition rate : 10 cfs to 2 Mcfs, 20 kc/s to 20 Mc/s, resp.

External triggering and single triggering facility pro-

vided Output pulses : one or more inde­

pendent channels ac­cording to the con­figuration

Pulse width and delay: 100 ns to 10 ms, 10 ns to 20 !J.S,

resp.

Polarity :

Amplitude :

Rise and fall t ime :

Dimensions :

Manufactured by EMG

positive and negative, simultaneously max. 10 V (into SO ohms) _,.:; 5 ns (typically 3 ns) 177 X 436 X 195 mm

WORKS FOR .;LECTRONIC MEASURING GEAR Budapest XVI., Cziriky u. 26-32. HUNGARY Telex : 33-50.

METRIMPEX

EMG -1157 TR-0354/5/6 Modular Pulse Generator

The special design of the instrument renders possible the optional variation of two or more pulses. The circu its are interchangeable plug-in units. By assembling the available various units in different combinations it is possible to realize a generator with the tech­nical characteristics best suited for the given pu r pose. The pulse repetition rate, delay, width and ampl itude can be ad justed separately. The instrument is fully t rans istorized . Its units are the following:

master generators delay units pulse output units attenuator units

Exported by HUNGARIAN FOREIGN TRADING COMPANY FOR INSTRUMENTS Budapest, 62. P.O .B. 2C2

ORION®E M G

Cable : INSTRUMENT, Budapest, HUNGARY

69.1417 E1yecemi Nyomda m"ynyomba, Budapett (Macyar Hirde<6)

Page 11: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

...._____.,._EL_ECTRONIC VOLTMETERS AND AMMET_ER_S~____, ELECTRONIC VOLTMETERS FOR AC VOLTAGE MEASUREMENTS

EMG-1314 TR-1103 V.T. Voltmeter 10 to 20 cfs, or

The Instrument is a Y.T.Y.M., of a very stable amplifier system. It is used for measuring AC voltages between 5 mY and 300 V in the frequency range of 10 c/s to 1 Mcfs. It can also be used as a measuring amplifier.

300 to 1,000 kc/s, resp.: ± S% SYMMETRICAL INPUT Measuring range: SO !J.Y to 10 V

±3% f.s.d.

Measuring range :

Measuring accuracy (at 1 kc/s): Frequency range : Frequency response (related to 1 kc/s) 20 cfs to 300 kc/s: 10 to 20 cfs, or 300 to 1,000 kcfs, resp.: Dimensions :

5 mY to 300 Y (in 9 ranges) ±2% f.s.d. 10 cfs to 1 Mcfs

±2%

±5% 236 x 180 x 250 mm

EMG-1319 TR-1202 Sensitive V.T. Voltmeter

The Instrument is used for measuring symmetrical and asymmet­rical AC voltages between 50 fLY and 300 Y in frequency range of 10 cfs to 1 Mcfs. It can also be used as a measuring amplifier.

ASYMMETRICAL INPUT Measuring range:

Measuring accuracy (at 1 kc/s): Frequency range : Frequency response (related to 1 kc/s) 20 cfs to 300 kcfs :

50 fLY to 300 V (in 13 ranges)

± 2% f.s.d. 10 cfs to 1 Mcfs

± 2%

EMG-1324 TR-1301 Wide Band V.T. Voltmeter

The instrument Is designed for measuring low-level AC voltages over a wide frequency range. The signal to be measured reaches the measuring probe either directly, or at low-level signal measurement, through a pre-divider.

Measuring range:

Measuring accuracy : Frequency range : Frequency response (related to SO kc/s) 1 kc/s to 10 Mcfs : 10 Mcfs to 30 Mc/s : (without pre-divider) Dimensions:

100 !J.Y to 30 Y (in 10 ranges) ±3% f.s.d. 1 kc/s to 30 Mcfs

±S% ±8%

26S x 200 x 36S mm

Measuring accuracy: Frequency range :

Dimensions :

60 cfs to 20 kc/s. or 3 kcfs to 300 kc/s, resp. 26S x 200 x 28S mm

EMG-1322 TR-1204 Precision V.T . Voltmeter

The instrument is a very accurate, high stability V.T. Voltmeter, which can be used for measuring AC voltages between SO fLY and 300 V in the frequency range of 10 cfs to 5 Mc/s. Owing to the high accuracy obtained, it is also suitable for laboratory precision measurements.

Measuring range :

Measuring accuracy (at 1 kcfs): Frequency range: Frequency response (related to 1 kc/s) 50 cfs to SOO kcfs: 20 to SO cfs, or SOO to 1,000 kcfs, resp.: 10 to 20 cfs, or 1 to 5 Mcfs, resp.: Dimensions :

SO fLY to 300. Y (in 12 ranges)

± 1% f.s.d . 10 cfs to S Mcfs

±1%

±2%

±5% 26S x 200 x28S mm

Page 12: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-1325 TR -1351 RF Millivoltmeter

The instrument is used for measuring AC voltages between 1 mV and 10 V in the frequency range of 0.5 to 1,000 Mcfs. The measuring range can be extended up to 1,000 V by means of a divider. The RF measurements can be performed by means of several measuring probes. The instrument is fully transistorized.

Measuring range: 1 mV to 10 V

Frequency range : M easu ring accuracy 0.5 to 50 Mcjs : 50 to 150 Mcjs : 150 to 1,000 Mcfs : Dimens ions:

EMG-1353 TR-1453 Transistorized AC Voltmeter

The instrument is used for measuring AC voltages between 100 fi.V to 300 V in the frequency range of 1 c fs to 1 Mcfs. It is fully transistorized, small size, can be operated from battery.

Measuring range: 100 fi.Y to 300 V

Measuring accuracy : Frequency range : Frequency response (related to 1 kcfs) 5 cfs to 500 kcjs : 1 to 5 cfs, or 500 to 1,000 kc /s, resp.: Dimensions :

DC AMMETER

EMG-1J48 TR-1104 DC Milliammeter

(in 12 ranges) ±3% f.s .d. 1 cjs to 1 Mcjs

±3%

±5% 165 x 180 x1 10 mm

The instrument can be used for measuring DC in the range of 0 .3 mA to 1 A. The current can be measured without breaking the circuit, by means of a measuring probe damped on the conductor.

Measuring range :

Measuring accuracy: Dimensions :

0.3 rnA to 1 A (in 6 rang es) ± 3% f.s.d. 236 x 180 x 320 mm

DC VOLTMETER-AMMETER

(in 7 ranges) 0.5 to 1,000 Mcfs

±3% f.s.d. ±6% f.s .d. ±1 dB f.s.d. 247 X 196 X 300 mm

EMG-1352 TR-1452 DC Microvolt-Ammeter

The instrument is suitable for measu r ing very low positive and negative DC voltages and currents. It can be used as a DC amplifier.

VOLTAGE MEASUREMENT Measuring range : Measuring accuracy : CURRENT MEASUREMENT Measuring range : Measuring accu racy: Dimensions:

1 t,J.Y to 1 V (±) ±3% f.s.d.

1 pA to 3 rnA (±) ±3% f.s.d. 247 x 196 x 300 mm

Page 13: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

ELECTRONIC VOLTMETERS FOR AC, DC VOLTAGE AND RESISTANCE MEASUREMENTS

EMG-1341 / E TR-1401-E " ORIVOHM II" Workshop V.T. Volt­meter

The instrument is an easily operated V.T. Voltmeter of dependable construction, designed for measuring DC and AC voltages as well as resistances.

DC VOLTAGE MEASUREMENT: Measuring accuracy: AC VOLTAGE MEASUREMENT: Measuring accuracy : Frequency range: RESISTANCE MEASUREMENT:

Measuring accuracy : Dimensions :

100 mY to 1,000 V ±3% f.s.d. 200 mY to 300 V ±5% f.s.d. 30 cfs to 25 Mcfs 0.2 ohm to 1,000 Mohms ±5% at mid-scale 180 x236x145 mm

EMG-1344 TR-1405 Voltage, Resistance Meter (HT and HF)

The instrument is used for measuring DC and AC voltages as well as resistances. With a separate HT measuring probe DC voltages up to 30 kV and by means of the HF measuring probe AC voltages up t o 700 Mc/s can be measured.

DC VOLTAGE MEASUREMENT : Measuring accuracy : With the HT probe: AC VOLTAGE MEASUREMENT : Measuring accuracy: Frequency range: With the H F probe : RESISTANCE MEASUREMENT :

Measuring accuracy : Dimensions :

EMG-1345 TR-1406 Electronic Multimeter

20 mY to 1,000 V ± 3% f.s.d . up to 30 kV 100 mY to 300 V ± 5% f.s .d. 30 cfs to 5 Mcfs 1 kcfs to 700 Mcfs 0 .2 ohm to 1,000 Mohms ±5% at mid-scale 180 x 236 x 145 mm

The instrument is an easily operated V.T. Voltmeter, designed for measuring DC and AC voltages, DC currents as well as resistances. HT and HF measuring probes can also be used with the instrument.

DC VOLTAGE MEASUREMENT : 20 mV to 1,000 V Measur ing accuracy: ± 2.5% f.s :d. With the HT probe : up to 30 kV AC VOLTAGE MEASUREMENT : 100 mV to 300 V Measu ring accuracy : ± 3% f.s.d. Frequency range: 30 cfs to 5 Mcfs With the H F probe : 10 kc/s to 700 Mcfs RESISTANCE MEASUREMENT: 0.2 ohm

to 1,000 Mohms Measuring accuracy : ±5% at mid-scale DC MEASUREMENT : 0.1 rnA

to 1,000 rnA Dimensions: 220 x 180 x 210 mm

EMG-1346 TR-1407 "TRANSORIVOHM" Universal Voltmeter

It is an easy handling, safe operation, fu lly transistorized universal V.T. voltmeter . By means of the instrument DC and AC voltages as well as resistances can be measured.

DC VOLTAGE MEASUREMENT : Measuring accuracy: AC VOLTAGE MEASUREMENT: Measuring accuracy : Frequency range: RESISTANCE MEASUREMENT : Measuring accuracy : Dimensions :

10 mV to 1,000 V ± 2% f.s .d. 1 mV to 300 V ±3% f.s.d. 10 cfs to 1 Mcfs 1 ohm to 50 Mohms ± 5% at mid-scale 131 x 180 x 174 mm

Page 14: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

-·--- • MEASURING AMPLIFIERS ~·

EMG-1375 TR-1205 High-gain DC Amplifier

The instrument can be used together with the plug-in amplifier unit EMG-1589-U-11 as measuring amplifier. Its high zero point stability makes it suitable for the amplification of DC voltages in the order of 50-100 ;;.V.

Amplification:

Accuracy of input attenuator: Frequency range:

Linear distortion (related to 1 kc/s): Zero point stability (related to input) : Output voltage :

Dimensions:

20,000 to 0.04 (in 18 bands) ±2% DC to 250 kc{s (can be switched over in 5 steps)

± 3 dB

25 ;;.V /hour max. ±15 V DC or max. 10 Yrms 290 x 200 x 433 mm

EMG-1376 TR-1206 AC Measuring Amplifier

The instrument serves for the amplification of low AC voltages over a wide frequency range.

Amplification: max. 60 dB (in 6 steps)

Accuracy of amplification (at 1 kc/s): Frequency range: Linear distortion (related to 1 kc/s) 20 cfs to 1 Mcfs: 10 to 20 cfs, or 1 to 5 Mcfs, resp.: Output voltage: Dimensions:

±0.5 dB 10 cfs to 5 Mcfs

±0.5 dB

±1 dB max. 2 V 265 >q_OO x 285 mm

MICROWAVE POWER METERS

EMG-1383 TZA-353 Transistorized Microwave Power Meter

The fully transistorized instrument, together with the thermistor measuring probe, which can be connected to it, is used to measure H F or microwave power.

Measuring range:

Measuring accuracy: Frequency range (with measuring probe EMG-1383 /5): Dimensions :

Manufactured by EMG

0.01 to 10 mW (in 5 ranges) ± 5% f.s.d.

10 Mcfs to 10 Gcfs 236 x 180 x 145 mm

EMG-1384 TZA-354 Transistorized Microwave Power Meter (temperature compensated)

Combined with the temperature compensated thermistor mea­suring probe, the instrument is suitable for measuring HF and microwave power. Fully transistorized.

Measuring range:

Measuring accuracy: Frequency range (with measuring probe Dimensions :

EM G-1384/5):

1 u.W to 10 mW ( i~ 7 ranges) ±5% f.s.d.

10 Mcfs to 10 Gcfs 250x190x330 mm

WORKS FOR ELECTRONIC MEASURING GEAR Budapest, XVI., Cziriky u. 26-32. HUNGARY Telex: 33-50.

METRIMPEX s HUNGARIAN FOREIGN TRADING COMPANY FOR INSTRUMENTS 0 R I 0 N ( . . ) E M G Budapest, 62. P.O.B. 202 , Cable : INSTRUMENT, Budapest, HUNGARY

Exported by

69.1417 qyetemi Nyomda m61ynyomlsa, Budapest (Manar Hirdec6)

Page 15: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

DIGITAL VOLTMETERS AND FREQUENCY METERS DIGITAL VOLTMETERS AND CONVERTERS

EMG-1361 TR-1651 Digital DC Voltmeter

The instrument has been designed to measure DC voltages within a voltage range of 100 fJ.V to 1,000 V with 0.1% accuracy. The measured result is displayed by four in-line numerical indicator tubes.

Measuring range:

Upper limits of measuring ranges :

Measuring accuracy : Period time of one measurement: Dimensions:

100 !J.Y to 1,000 V (in 5 ranges) 0.1599 v. 1.599 v. 15.99 v. 159.9 v. 1,000 v ±0.1% of f. s. 280 ms 240x500x380 mm

EMG-1365 TR-1753 ResistancefDC Converter

Connected to the EMG-1361 Digital DC Voltmeter, the instru­ment is suitable for the accurate measurement of ohmic resitances in a wide range.

Measuring range :

Measuring accuracy : Dimensions:

EMG-1367 TR-1751 ACfDC Converter

0.1 ohm to 10 Mohms (in 6 ranges) ±0.2% of f.s . 190 x500x380 mm

Connected to the EMG-1361 Digital DC Voltmeter, the instru­ment is suitable for high accuracy measurement of AC voltages.

Measuring range : 50 uV to 300 V (in '10 ranges)

Frequency range: Measuring accuracy 50 cfs to 50 kcfs: 20 to 50 cfs, or 50 to 500 kcfs, resp. : Dimensions :

20 cfs to 500 kcfs

±0.5% of f.s.

±2.5 of f.s . 150x500x380 mm

EMG -1362 TR-1652 Digital DC Voltmeter

The instrument is a four-digit digital DC Voltmeter with h1gh accuracy and high sensitivity.

Measuring range :

Upper limits of measuring ranges:

Range selection : Measuring accuracy :

Period time of one measurement: Dimensions :

20 u.V to 1,000 V (in 's ranges) 0.19998 v. 1.9999 v. 19.999 v. 199.99 v. 1,000 v manual or automatic ± 0.01% ± 1 digit of f.s . 20 ms 240 x 500 X 390 mm

EMG-1368 TR-1752 AC/ DC Converter

Connect.ed to the EMG-1362 Digital DC Voltmeter, the instru­ment is suitable for high accuracy measurement of AC voltages .

Measuring range : 0.2 mY to 200 Y

Frequency range : Measuring accuracy: (in' ranges of 2, 20, 200 V, between 30 cfs and 2.5 kc/s) Dimensions :

(in 4 ranges) 30 cfs to 10 kcfs ±0.04% of f.s ., ±0.05% of reading

120 x 440 x 400 mm

i/j.

Page 16: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

"' 4 ~; c; c I

DlGIUL MULTIIHTft TfPf , __

EMG-1369 TR-2251 Digital Resistance Meter

The instrument is used for highly accurate measurement of resistances. The measured result appears on five in-line numerical indicator tubes.

Measuring range :

Measuring accuracy: Measuring time : DImensions :

5 mohms to 200 Mohms (in 8 ranges) ±0.04% of f.s. 380 ms 180x436x360 mm

EMG-1363 TR-1653 Integrating Digital DC Voltmeter

The instrument has been designed for measuring DC voltages within a very wide voltage range (10 !J.Y to 1,000 V) with 0.05% accuracy. The measurement result is displayed by four in-line numerical indicator tubes. The application of integrating technics ensures efficient common mode rejection. Measu ri ng range: 10 !J.Y to 1,000 V

Measuring ranges:

Measuring accuracy:

Period time of one measurement: Dimensions:

(in 6 ranges) 20, 200 mY, 2, 20, 200, 1,000 v ±0.05% ± 1 digit of f.s. 30 ms 135 x440x375 mm

EMG-1366 TR-1754 ACJDC and ResistancefDC Converter

Connected to the EMG-1363 Integrating Digital DC Voltmeter, the instrument is suitable for high accuracy measurement of AC voltages as well as resistances. AC VOLTAGE MEASUREMENT Measuring range : 100 !J.V to 200 V

(in 5 ranges) Measuring accuracy 50 cfs to 50 kc/s: 20 cfs to 500 kc/s: RESISTANCE MEASUREMENT Measurement range:

Measuring accuracy 200 ohms to 2 Mohms : 2 Mohms to 20 Mohms : Dimensions :

EMG-1364 TR-1654 Digital Mu ltimeter

± 0.5% of f.s. ±2% of f.s .

0.1 ohm to 20 Mohms (in 6 ran~es)

±0.~% of f.s. ±0.5% of f.s . 90 x 440 x 430 mm

The instrument can be used for fast and accurate measurement of AC and DC voltages as well as resistances. The measured result is displayed by four in-line numerical indicator tubes. DC VOLTAGE MEASUREMENT Measuring range :

Measuring ranges : Measuring accuracy : Period t ime of one measurem ent : AC VOLTAGE MEASUREMENT Measuring range :

Measuring accuracy: Frequency range : RESISTANCE MEASUREMENT Measuring range :

Measuring accuracy : Dimensions:

2 mY to 500 V (in 3 ranges) 5, 50, 500 v ± 0.2% ±2 digits 300 ms

2 mY to 300 V (in 3 ranges) ± 0.2%±2 digits 40 cfs t o 10 kc/s

2 o hms to 500 kohm s (in 3 ranges) ± 0.5% ± 2 digits 107 x 265 x 310 mm

Page 17: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

DIGITAL FREQUENCY· AND TIME METERS

EMG-1645 TR-5250 Digital Frequency- and Time Meter

The instrument is designed primarily for laboratory purpos~s. for the measurement of frequency , period time, average period time, pulse width, time interval and frequency ratio. It can al~o be used the totalizing count. The measured result appears on seven in-line numerical indicator tubes. Frequency measurement: Totalizing counting: Period time measurement :

Average period time measurement: Pulse width measurement :

Time interval measurement :

Sensitivity:

0 to 10 Mcfs max. 107 pulse 0 to 1 Mcfs (measurable shortest time 1 f.LS) 10° to 107 periods measurable shortest pulse 1 f.LS measurable shortest time interval 1 f.LS 100 mVrms

Stability of bu ilt-in time base generator: 1.10- 7 fweek,

Dimensions : 5. 10- 8 /day HOx500x380 mm

EMG-1647 TR-5301 Frequency Range Extender for 10 Mc/s Counter/Frequency Meter

Connected to the EMG-1645 Digital Frequency - and Time Meter, the instrument can be used to extend the basic frequency range . It can be operated with two types of converter units. WITH EMG-1689-U-91 CONVERTER UNIT (TR-5302) Frequency range: 10 Mcfs to 100 M cfs Sensitivity: 20 mVrms WITH EMG-1689-U-92 CONVERTER UNIT (TR-5303) Frequency range : 100 Mc/s to 220 Mc/s Sensitivity: 100 mVrms Dimensions : 190 x 500 x 380 mm

EMG-1642 TR-5252 Digital Frequency- and Time Meter

The instrument is used for the measurement of frequency, frequency ratio, period time, average period time, time Interval as well as totalizing count. The measured result appears on six in-l ine numerical indicator tubes. Frequency measurement: Average period time measurement :

Time interval measurement : Totalizing counting : Sensitivity :

1 c/s to 1.2 Mcfs 1 c/s to 1.2 Mcfs, 10° to 105 period 1 f.LS to 108 s 1 cfs to 1,2 Mcfs 100 mVrms

Stabilit y of the built-in crystal Dimensions:

oscillator : 1.10- 6 /day 165x440x440 mrn

Page 18: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

DFT MfiU rm 11

5 (' r, .. ; (. ' '

EMG-1646 Digital Frequency- and Time Meter

The basic instrument type EMG-1646 can be used to measure frequency in the range of 0 to 100 Mc fs, with the Frequency Converter plug-in unit type EMG-1689-U-82 the instrument can be used for frequency measurements up to 3,1 Gcfs. At time measurements the resolution of the instrument is 10 ns. The stability of the built-in time base generator is 5.10- 9 . The instru­ment is fully transistorized, the measured result appears on nine In-line numerical indicator tubes. A printer can be connected to the instrument, operated by a 4-line BCD code output signal. FREQUENCY MEASUREMENT Measuring range DC coupled input : AC coupled input: Gate time:

PERIOD TIME MEASUREMENT Measuring range : At average period time measurement: Averaging factor :

0 to 100 Mcfs 100 cfs to 100 Mcfs 1 f.'S to 10 s, can be adjusted in decadic steps

0 to 1 Mc/s 0 to 100 kc/s 1 to 105 period , in decadic steps

EMG-1643 Digital Frequency· and Time Meter

The instrument is used for the measurement of frequency, frequency ratio, period time, average period time, totalizing time interval, totalizing count. The portable instrument contains only silicon transistors and is characterized by low weight and small size. It can be used for industrial and laboratory mea-surements. Frequency measurement: Period time measurement: Totalizing counting: Input voltage (i n case of sinusoidal signal) : Time interval and totalizing t ime interval measurement : Frequency ratio measurement:

Operating temperature range: Change of reference frequency {between 0 °C and +SO 0 C) : Dimensions :

Frequency counted :

OTHER DATA Sensitivity: Frequency of time base : Stability of time base: Dimensions :

EMG-1689-U-82 Frequency Converter

c fs to 1.S Mcfs s to 10 f.'S cf s to 1.5 Mc/s

200 mVrms to 1SO Yrms

10 IJ.S to 9999 s fA= 1 cfs to 1.5 Mcfs fs=O to 100 kc/s 0 °C to +SO °C

max. 8.10- 5

107 x 26S x 212 mm

1 c/s to 100 Mcfs, in decadic steps (resolution in 10 ns)

100 mV 5 Mc/s 5.10- 9

177 x443 x 400 mm

The Frequency Converter, as a plug-in unit, widens the field of application of the Digital Frequency and T ime Meter type EMG-1646. It ensures high-accuracy and high-resolution mea­surements in the frequency rangeof100 to 3100 Mcfs . It is fully transistorized . Frequency measurement : Sensitivity :

Dimensions :

100 to 3,100 Mc /s 50 mV (100 to 2,500 Mcfs) 100 mV (2,SOO to 3,100 Mcfs) 160 x 120x210 mm

1 0 0 0 0 0 p 0 ·Q ... I

Manufactured by EMG

Exported by

WORKS FOR ELECTRONIC MEASURING GEAR Budapest XVI., Cziraky u. 26-32. HUNGARY Telex : 33-SO.

METRIMPEX HUNGARIAN FOREIGN TRADING COMPANY FOR INSTRUMENTS Budapest, 62. P.O.B. 202 Cable : INSTRUMENT, Budapest. HUNGARY

" .2417 E1yetemi Nyomda m"yr.yomua, Buclap•t (Ma1yar Hlrdet6)

Page 19: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

HIGH FREQUENCY OSCILLOSCOPES

EMG-1546 TR-<4401 .HF Oscilloscope

The instrument is designed for the examination of electrica l phenomena taking over a wide frequency range . The plug-in preamplifier layout ensures its wide field of application .

CATHODE-RAY TUBE : 130 mm screen diameter

VERTICAL AMPLIFIER. Technical data are determined by the particular plug-in unit HORIZONTAL AMPLIFIER Bandwidth: Sensitivity :

TIME BASE GENERATOR Sweep rate: Dimensions :

DC to 250 kc /s 200 mV /em to 20 Vfcm

5 sf em to 0.1 ':J.S /cm 430 x 320 x 620 mm

EMG-1539 TR-4103 Oscilloscope (hish sensitivity)

The Ottilloscope is designed for testing low level signals very frequently encountered in the field of telecommunication en­gineering and measuring techniques. The vertical amplifier of the instrument is a plug-in unit.

CATHODE-RAY TUBE:

VERTICAL AMPLIFIER Technical data are determined HORIZONTAL AMPLIFIER Bandwidth: Sensitivity:

TIME BASE GENERATOR Sweep rate : Dimensions:

130 mm screen diameter

by the particular plug-in unit

DC to 300 kc/s 200 mVfcm to 20 v;cm

1 fJ.S/cm to 5 sfcm 360 x 260 x 570 mm

Its interchangeable plug-in units are the following :

EMG-1589-U-13 TR-4708 HiJh·gain Differential Amplifier

It makes the oscilloscope suitable to carry out industrial mea­surements as well. The plug-in units is provided with a differential input.

Modes of operation:

Bandwidth: Sensitivity:

A, A-B, B input with AC, DC coupling DC to 300 kcfs 1 mVtcm to 50 V /em

EMG-1589-U-11 TR-4709 High-gain Amplifier

It allows to increase the vertical sensitivity of the osc illoscope up to 100 fJ.Vfcm. The bandwidth can be changed ove r in fi ve steps between 250 and 0.5 kcfs.

Input connection : Frequency range : Sensitivity :

DC, AC DC to 250 kc Is

100 ;;.Vfcm to so v,cm

Page 20: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-1552 TR-4602 Dual-beam HF Oscilloscope

It is designed for the observation of electrical phenomena taking place over a wide frequency range. It is particularly useful for the examination of two time-connected phenomena, simulta­neously. Its specification is identical with that of the oscilloscope type EMG -1546, but si nee it has two vertical deflection systems. it can accommodate two plug-in preamplifiers.

The Interchangeable plug-in units of the oscilloscopes type EMG-1546 and EMG-1SS2 are the following:

EMG-1S89-U-1 TR-4704 Wide-band DC Preamplif ier

Input connection : DC, AC Bandwidth used in EMG-1546 : used in EMG-1SS2 : Sensitivity :

DC to 30 Mcfs DC to 25 Mc/s SO mY {em to 20 V {em

EMG-1589-U-2 TR-'4705 Dual-trace DC Preamplifier

Input connection : DC, AC Modes of operation : only channel A

only channel B CHOPPED ALTERNATE both channels

Bandwidth : Sensitivity :

summarized DC to 20 Mcfs 50 mY/em to 20 Vfcm

EMG-1589-U-3 TR--4706 High-gain Differential Preamplifier

Modes of operation :

Bandwidth in position 1 mVfcm: in position SO mY/em : Sensitivity :

A, A-B, B input with DC, AC coupled

DC to 250 kc/s DC to 1.5 Mc/s 1 mVfcm to 50 Vfcm

EMG-1589-U--4 TR-4710 Transistor Rise-time Measuring Unit

It serves for the measurement of pulse transmission data of transistors. Pulse amplitude: Co II ector current: Rise-time representable on screen : Collector voltage:

EMG-1549/2 TR-4404 HF Oscilloscope

0.05 to 10 V 0.5 to 100 mAfcm min. 12 ns 1 to 15 V

it can be used for the observation of fast signals in a wide fre­quency range. The plug-in preamplifier layout ensures a wide field of application. It consists of two internal time base genera · tors providing accurate and continuous delayed sweep.

CATHODE-RAY TUBE : 130 mm screen diameter

VERTICAL AM PLIFIER Technical data are determined by the particular plug-in unit HORIZONTAL AMPLIFIER Bandwidth : Sensitivity ;

"A" TIME BASE GENERATOR Sweep rate : "B" TIME BASE GENERATOR Sweep rate : DELAYED SWEEP : Dimensions;

EMG-1549/1 TR-4-405 HF Oscilloscope

DC to 250 kc /s 200 mVfcm to 20 Vfcm

2 sfcm to 0.05 iJ.s/cm

1 sfcm to 2 fJ.S /c m 10 S tO 1 !J.S

-430 X 320 X 620 mm

Its specifications are identical with that of the oscilloscope EMG-1549/2 but it has only one time base generator, thus de layed sweep is not possible.

Page 21: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

The interchangeable plug-in units of the osc illoscopes type EMG -15-49/2 and EMG-15-4911 are the following:

EMG-1589-U-21 TR -4712 Wide-band DC Preamplifier

Input connect io n : Bandwidth : Sensitivity :

DC. AC , G N D DC to 45 Mc/s SO mVfcm co 20 Vfcm

EMG-1589-U-22 TR-4713 Dua l-trace DC Prea mplifier

Input connectio n: Modes of operation :

DC , AC, GN D only channel A only channel B CHOPPED ALTE RNATE

TRANSISTORIZED OSCILLOSCOPES

EMG-1563 TR-4651 "TRANSISCOPE- M" O sci llosco pe

The fully t ransistorized , small size oscilloscope serves for t he observation of elect rical phenomena caking place over a w ide frequency range. CATHODE-RAY TU BE· 70 mm

screen diameter VERTICAL AMPLIFI ER AC, DC coupled Bandwidth : DC to 10 Mcfs Sensitivity : 50 mY /div

co 20 V /div

HORI ZONTAL AMPLI FIER Bandwidt h : Sensitivity: TIM E BAS E GENERATOR Sweep rate :

Dimensions :

(1 div:0.6 em)

DC to 1 Mc/s min. 100 mV /div

0 .2 ;J.S/d iv co 0.5 sfdiv 200 x 160 x 340 mm

EMG-1565 TR-4652 " TRANSISCOPE-K " Low Frequenc y Osci lloscope

The oscilloscope can be used for testing low level signals very fre quent in the fie ld of telecomm unicat ion enginee ri ng and measu ring techniques. It is a fully transistorized, small size osci lloscope. CATHODE-RAY TUBE : 70 m m

VERTICAL AMPLIFIER Modes of ope rat ion :

Bandwidth : Sensitivity :

HO RI ZONTAL AMPLIFIER Bandwidth : Sensitivity : TIM E BASE GENERATOR Sweep rate · Dimensions·

scree n d iamete r with diff. in put A, A - B, B inp ut, with AC, DC cou pled DC to 300 kcfs · 1 mY /div to 10 V /d iv (1 di v= 0 .6 em)

DC to 300 kcfs min. 100 mV fdiv

1 ;J.S /dlv to 0.5 sfdiv 200 x 160 x 340 mm

Ba'ldwidt h : D:: to -45 Mcfs Sensitivity : 50 mV /em to 20 V fcm

EMG -1589-U-23 T R-4714 Hi&h-&ain Differential Prea mplifier

Modes of operation :

Bandwidth : in position 1 mV /em: in position 50 mVfcm : Sensit ivity:

A, A- B, B input, with AC, DC coupling

DC to 250 kc/s DC to 1.5 Mcfs 1 mVfcm to 50 Vfcm

EMG-1589-U -24 T R-4715 Transistor Rise-t ime Measu ring Unit

The pl ug-in unit se rves for t he measure ment of pu lse transmission dau of t ransistors. Pulse amplitude : Collector current : Rise time representable on the screen : Collector voltage:

0.05 to 10 V 0.5 to 100 mAfcm min . 12 ns 1 to 15 V

EMG-1589-'J-25 T R-4716 Four-trace DC Preamplifier

Modes of operation (MOD E) :

Bandwidth : Sensitivity :

DC NO RM, AC NORM, OFF, AC INV, DC INV. A LTERNATE or CHO PPE D independent of the MOD E switch DC to 20 Mcfs 20 mV/cm to 10 Vfcm

E,'1G-15S6 TR-4650 "TRANSISCOPE-D" D ual Trace Oscil· losco pe

It is for the observation of ele ctrical phenomena t aking place over a wide frequency range. It is particularly useful for examining two time-connected phenomena simultaneously. The instrument is fu lly transistorized. CATHODE-RAY TU BE: 10:> mm

VERTICAL AM PLIFIER Input connection: Modes of operation:

Bandwidt h : Sensitivity :

HORIZONTAL AMPLIFIER Bandwidth : Sensitivity: TIME BASE G EN ERATOR Sweep rate :

Dimensions :

screen diameter

DC, AC, GND CH1 only CH2 on ly dual trace CHO PPED dual t race

ALTERNATE DC to 20 Mcfs 50 mVjcm to 20 Vfcm

DC to 1 Mcfs min. 100 mVfcm

0.2 ;J.S/Cm to 0 .5 sfcm 255 x 200 x 385 mm

Page 22: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

CHARACTERISTIC CURVE TRACER

EMG-1579 TR-4802, 4803 Characteristic Curve Tracer

The instrument serves to measure quickly the parameters of several circuit components. The characteristic curves of compo­nents to be tested appear on the screen of a cathode-ray tube. The instrument is suitable fo r accommodati ng two plug-in units. The plug-in units are the following: Amplifier and Tolerance unit EMG-1579-U-71; Transistor and Diode Test unit EMG-1579-U-72; Electron Tube Test unit EM G-1579-l,J-73. With these plug-in units the instrument aan be used two different operating modes.

EMG-1579-102 (TR-4802) (with U-71, U-72 units) for the testing of resistances, VD R resistances, tliodes, Zener diodes and tran­sistors.

EMG-1579-103 (TR-4803) (with U-71, U-73 units) for the testing of resistances, VDR resistances, diodes, Zener diodes, electron tubes and Nuvistors. Simultaneously, two components can be tested (reference and tested). The built-in step-generator faci­litates the simultaneous checking of curves corresponding to several parameters. Useful picture area: Dimensions:

8x8 em 220 x 437 x 460 mm

EMG-1S79-U-71 TR-4717 Amplifier and Tolerance unit

It facilitates the adjustment of the tolerance field of the reference characteristic. Positive tolerance limits: Negative tolerance limits:

0-5-10-20-50-100~ 0-5-10-20-50~

EMG-1S79-U-72 TR-4718 Transist o r and Diode Test unit

Collector sweep voltage · Base sweep vol tage: Base current steps:

METRtMPEX

0 tO 500 Vp 0 to 2 V 0 to 0.2 A/step

number of steps w hich can be plotted : Horizontal deflection measuring collector sweep voltage : measuring base sweep voltage · Vertical deflection:

4 to 10

0 to 50 Vfdiv 0 to 0.2 Vfdiv 0 to 1 A/ div

EMG-1579-U-73 TR-4719 Electron Tube T est unit

Anode sweep voltage : Control grid sweep voltage: Control grid step voltage : number of steps which can be plotted : Horizontal deflection measuring anode sweep voltage : measuring control grid sweep voltage: Vertical deflection :

0 to SOO Vp 0 to 50 Vp 0 to 2 V /step 0 tO 10

0 to SO Vfdiv 0 to 5 Vldiv 0 to SO mAfdiv

PORTABLE OSCILLOSCOPE FOR TV-SERVIC ING

EMG-1582 TR-0824 "SWEEPOVOHM" Po rtable O sci llos­cope and Teste r for TV-servicing

The instrument can be used for on the site measurement and repair of TV sets. It is possible to carry out almost every kind of measurements which may be necessary at the repair of TV sets. Simple handling, small size and low weight are its features . CATHODE-RAY TUBE: 70 mm

DC VOLTAGE MEASUREME NT : in terminal "V x 10": with probe of 100 : 1 attenuation : AC VOLTAGE MEASUREMENT : in terminal "V x 10" : Frequency range: with HF probe: RESISTANCE MEASUREMENT : SO cfs IMPEDANCE MEASUREMENT: CAPACITANCE MEASUREMENT : INDUCTANCE MEAS UREMENT: HF SWEE P SIGNAL :

SIGNAL OF THE BAR PATTERN GENERATOR ·

Dimensions :

screen diameter 0 to 300 V max. 500 V max. 20 kV 0 to 100 Vrms max. 3SO V rms 0 to 2SO kc/s 100 kc/s to 300 Mcfs

1 ohm to 10 Mohms 1 ohm to 10 Mohms 10 pF to 10,000 f.L F t mH to 100 H 30 to 230 Mcfs wit h min. 10 Mcfs deviation

25 to SO c fs, 300 to 600 c fs, 5 to 10 kcfs 170 x 106 x 189 mm

Exported by HUNGARIAN FOREIGN TRADING COMPANY BudapeSt, 62. P.O.B. 201 Cable; INSTP..UHENT, 8\ldapest. HUNGARY .

Page 23: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

"

..

DC POWER SUPPLIES

EMG-1836/1 TR-9103

EMG-1836/2 TR-9104

EHG-1835{1 TR-9105

EHG-1835/2 TR-9106 Stabilized DC Power Supplies

The ·oc Power Supplies can be used in a wide field of electron ics. The types EHG-1835/1 and EMG-1835[2 differ only in respect of the accuracy of the output volt~e (EMG-1835/ 1: ± 1%±1 Y : EMG-1835/2: ±2%±2 V). Apart from type EHG-1836/ 1, the instrumenu contain built·in indicating meters. The types EMG -1835/1 and EHG-1835/ 2 are provided with overcurrent ,protec­tion . The lnstrumenu supply also . 2 x 6.3 V AC voltagl! fo r heating.

EMG -1836j1 EHG-1836/2 EMG-1835/1 EMG-1835/2 TR-9103 T~·910<4

Output voltage : Output current : Output voltage regulat ion : Change of output voltage (at ± 10% mains fluctuation) : AC output voltage : Dimensions:

EMG-1837 TR-9107 High Power Labor·atory Stabili:ted Power Supply

The inst rument supplies diffe rent st ab ilized DC voltages with in the limits of stab ili t y, power and output voltage required fo r laboratory and workshop use. It compr ises four independent supply units.

Unit I. 0 to 100 V ; 500 mA

O ut put voltage regu lat ion :

Accu racy of o ut put voltage : Stability (at ± 10% mains fl uctuation) :

Units 11- 111. 150 to 300 V; 100 mA

Out put . voltage regulat io n: Change of output voltage {at ± 10% mains fluctuat io n) :

Unit IV. 30 to 600 V; 200 mA

Outpu t voltage regulation :

Accuracy of output voltage : Change of output voltage (at ± 10% mains fluctuation) : AC output voltage : Dimensions:

in decadic steps of 10. 1 V and co nt i­nuously wit hin 0 to 1 v ±2% > 500 : 1

con t inuousl y

± 0.2%

in decadic steps of 100, 10, 1 v ±2% ± 2 v

±0.1%±150 mY 3x6.3 V; 2 A 270 x 443 x 373 mm

150 to 300 V 100 mA

continuously

±0.2% 2x6.3 V; 2 A

HO x 180x250 mm

TR~10S TR~106 30 t o 600 V

200 mA in decade steps of 100, 10, 1 V

±0.1%±150 mV 2 x 6.3 V; 3 A

290 x 205 x 380 mm

-··· •.

• ,,

Page 24: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-1851 T R-9150

EMG -1853 TR-9151

EMG - 1856 TR-915-4

EMG-1857 TR-9155 Transistorized Power Supplies

They are fully transistorized DC Power Supplies. The types EMG-1852 and EMG-1856 contain two independent units, which can be used independently of each other, In series and also In parallel operation. The output current is checked by a built-in indi­cating meter. The instruments are provided with overcurrent protection.

EMG-1852 EMG-1853 Output voltage TR-9150 TR-9151 and max. output current : 2 x 0to30 V; 1.5A Oto30V ;

orO to 60 V ; 1.5 A 1.5 A or 0 to 30 V; 3 A

Output voltage regulation : in decadic steps of 10; 1; 0.1 Y

Accuracy of output voltage : ±2% ±20 mY _ .. ~..... -r~0·-\,7 -;-: a· ·.~ .. · - ~ i

Stability (at ± 10% mains fluctuation) :

> 500 : 1 270x210x370 mm

@ ~· : r ·· ·.~· ·.~·

~~~ ; -~- -::=-_ -~- •

Dimensions :

EM G-1858 TR-9156 Laboratory Constant Voltaae1Constant Current Power Supply

The high-stability power supply can be operated in t he 0 to 30 V and 0 to 10 A ranges, both in the constant voltage and the constant current modes of ope ration . Output voltage and current can be checked by means of a bu ilt-in indicatinc meter. The power supply is provided with overload protection.

CONSTANT -VOLTAGE MODE 0 F OPERATION

Output voltage : Output voltage regulation :

Accuracy of output voltage : Rated loading range : Stability (at ± 10% mains fluctuation) :

0 to 30 Y in decad ic steps of 10; 1; 0.1 Y and continuously ±100 mY ±2%±3 mY 0 to 10 A

> 5000 : 1 or ±1 mY

CONSTANT-CURRENT MODE OF OPERATION

Output current ; Output current regulation :

Accuracy of output current: Output voltage range : Stabil ity (at ± 10% mains fluctuation) : Dimensions :

0 to 10 A in de cad ic steps of 1: 0.1 A ±2%±3 rnA 0 to 35 V

> 2500 : 1 or ±2 rnA 220x380 x HO mm

l..O x 180 x 250 mm

~o~, , I ...

-·-EMG-1855 EMG-1856 TR-915-4 TR-9155

l x O to 100 V; 0.5 A 0 to 100 V; 0.5 A

or 0 to 200 V; 0.5 A or 0 tO 100 V; 0.8 A

in decadic steps of 10.

1 V and continuously 0 to 1 V

±2% > 500 : 1 270 x 210 x 370 mm

HO x 180 x 250 mm

___ , ...

,.._.,. _____ _

Page 25: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

ELECTRONIC AC VOLTAGE STABILIZERS

EMG-2853 TR-9201

EMG-285-4 TR-9202

EMG-2855 TR-9203

EMG-2856 TR-9204 E lectr onic AC Vol taee Stabilizers

These instruments are us~d to eliminate the voltage fluctuations of the AC mains. The stabilizers supply a voltage of practically constant value, in case of a change of the mains voltage or of the load.

EMG-2853 TR-9201

EMG-2854 TR-9202

EMG-2855 TR-9203

EMG-2856 TR-9204

Ma,ns voltage .

Perm•ssible change of ma•ns voltage

Pe rmissible load of output · Output voltage : Change of output vo ltage in case of perm1s .

sible change of mains voltage. o r •n case of max. change of the load .

0 to 640 VA

220 V; 50 cfs, 1 phase

- 15% +10% 0 to 1,250 VA 0 to 2,500 VA

220 v

± 0.5%

0 to 5.000 VA

Dimensions : 320 x 420 x 320 mm 860 x 610 x 490 mm

EMG -2883 TR-9266 EMG-2884 TR-9267 Transistorized Electronic AC Vo ltage Stabi­lizers

The fully trans istonzed Inst r uments are wsed to elim1nate the voltage fluctuat ions of the mams.

Mains voltage : Per miss ibl e change of mai ns voltage : Permissible load of output Ou t pu t voltage · Change of output voltage 1n case of permissible change of mains voltage or in case of max. change of the load : Dimens ions :

EMG -2895 TR-9271

EMG-2883 EMG -2884 TR-9266 TR-9267

220 V. 50 c;s, 1 phase

- 15% + 10% 0 to 640 VA 0 to 1,250 VA

220 v

± 0.5% 240 X 500 X 385 mm

EMG-2896 TR-9272 Transistorize d Servo-type AC Vo ltage Stilbi ­lizers

The servo-type voltage sta bilizers have numerous advantages ove r th~ stabilizers with magnetic amplifiers.

Output powe r : in "wide-band" ope ration : in " narrow-band" operation : Mains voltage : Control range in "wide-band'' operation . in " nar row-band" operatio n . Output voltage : Dimensions:

EMG-2895 TR-9271

2500 VA 5000 VA

EMG -2896 TR-9272

5000 VA 10,000 VA

220 V, 1 phase

235 x 500x 410 mm

30% 15%

220 v 280x 500 x 410 mm

Page 26: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-2372 DD-250 Transistorized Stroboscope

The instrument can be used for determining the speed of rotating machine element, motors and gear transmissions. By means of the glow tube of the instrument, the measurement can be per­formed employing the stroboscopic effect. The instrument is fully transistorized, it has small dimensions, is battery operated. Measuring range : 500 to 15,000 r .p.m.

(flash frequency) Reading : on direct reading

frequency meter Accuracy of frequency meter : ±2% f.s.d. Dimensions : 166 x 237x 100 mm

EMG

INDUSTRIAL MEASURINCi INSTRUMENTS

EMG-2355 RZ-007 Transistorized Strain Gauge Measurin1 Bridce

The instrument is suitable for stat ic and dynamic measu rements of mechanical deformat ions . Measurements might be pe rformed e ither by the two- or by the four-gauge method. The Instrument is fully transistorized, it has small dimensions and is battery operated. Measurable stra in in middle position of measuring range extender switch : ± 129.,, i.e . 12.10- 3 t

(specific strain) Full measuring range in extreme positions of measuring extender switch :

Controllability of measuring li mits :

Maxi mum adjustment accuracy :

Frequency measurable with dynamic

+ or - 2-4o/00,

i.e. 24.10- 3 e (specific strain) in steps of 1X,., and further 2%o continuously ± 0.01 %., i.e. ±1 .10- 5 t

measurement: 0 t o 200 cjs Dimensions : 220 X 280 X 225 mm The field of application of t he instrument can be widened con­siderably by using t he adapte r type EMG-2352 (RZ-00-4). By means of t he adapters deformations can be measured on nu merous measuring places (max. 12 by adapter).

WOP.t<S FOR ELECTRONIC MEASURING GEAA Bu.est XVI .• Czirik)' u. l6-32. HUNGARY

Expom4 by

T.a.~e: 33·50.

HETPJHP.EX HUNGARIAN fOREIGN TRADING COMPANY FOP lNSTitVMENTS 8udape$t. 61. P.O.B. 201 cabl•l INSTRUMENT, Bu~. HUNGARY

6t.l417 IcY_, NJo•u ~~~.,.,..., ....,.t (Mtl11f Hl~ci'J.6)

:

Page 27: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-4581-13 Electromanometer The preamplifier is provided with a transducer appropriate for blood pressure measurement in the cardiac cavity and in the arterial system. EMG-4581-14 Cardiotachometer By means of appropriate transducers the preamplifier is suitable for the instrument

evaluation of heart rate. EMG-4581-17 Ballistocardiograph The preamplifier with an acceleration type ballistocardiograph transducer is suitable for measuring displacements of the body due to the mechanical action of the heart and the arterial system. EMG-4581-21 Narcosis Intensity Meter It is suitable for measuring narcosis intensity and for other neurological mea­surements. EMG-4581-22 Foetal phonocardiograph Preamplifier provided with microphone and stetoscope serving for the recording of foetal cardiac sounds. EMG-4581-23 Foetal electrocardiograph It can be used for recording of foetal electrocardiograms.

POL YPHYSIOGRAPH

EMG-4581 "BIOKOMB S" 5 + 2 Channel Polyphysiograph

"BIOKOMB 5" a 5 channel polyphysiograph, having 5+2 record­ing systems, is suitable for the measurement of heart action currents and further characteristics of the circulato ry system. Besides direct recording {thermal recorder) the eq ui pment is provided also with a two-channel photo recorder. At the same time it is possible to observe the s1gnals to be photorecorded also by an external double beam oscilloscope. The mechanical and electrical construction facilitates the simul­taneous use of four preamplifiers in addition to the ECG leads. This way, a test program most suited to the purpose can be set up. The preamplifiers can be connected to the desired recording channel by means of push buttons. In case of using the preampli­fiers, recording of cardiac sounds, blood pressure, rheogram and arterial pulsogram is facilitated. By means offurther preamplifiers it can be used in neurology, ballistocardiography and obstetrics as well. With five channels suitable for recording the heart actions the equipment can be used in all internationally known lead-out varieties. The equipment is of up-to-date design, fully transistorized. Dimensions: 210x 470 x 1,000 mm, its height with legs is 910 mm. Preamplifiers used for the equ ipment are the following : EMG-4581-11 Rheograph . A diagnostic preamplifie r, applicable in the field of cardiac-vascular pathology, serving for the recording of resistances of the blood-vascular system. EMG-4581-12 Phonocardiograph Preamplifier, equipped with microphone and stethoscope, serving for the ampl ification and band division (according to MAAS- WEBER) of cardiac sounds and noises.

Page 28: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

ELECTRO ENCEPHALOGRAPHS

EMG-4751 Eight-channel Electro Encephalograph

When performing electrophysiological examinations in neuro.

pathology and psychiatry, the equipment can be used for scien­

tific analysis as well as diagnostics. It serves for examination of the

bioelectric potentials of the cervix of the human brain and can

record the test data. It is an up-to-date design, easy to operate

equ ipment. 25 electrode points and 3 earthing points can be

connected to the equipment. By means of the selector switches,

any combination of the electrodes can be coupled to the inputs

of the 8 amplifier channels. The instrument is also provided

with interchangeable plug-in routine switches. Each routine

switch allows of the selection of 9 routine programs. The ampli­

fier channels are made as plug-in units. Max. sensitivity of the

channels is 1 mmff!.V. The built-in resistance meter serves for

measurement of the resistances of the electrodes. The built-in

calibrating unit facilitates recording of the cal ibrating voltage

changes. Recording is made with an inkwriti ng recorders on

paper charts.

Dimensions : 1175x1140 x780 mm

EMG-4752 Four-channel Electro Encephalograph

As the instrument is of a portable design, it can be used for the examination of patients who, for any reason, cannot oe transferred to the EEG laboratory. Just like instruments provided with more channels, there are connection facilities for 25 electrode and 3 earthing points on the instrument. By means of the selector switches, any combination of the electrodes can be coupled to the inputs of the four amplifier channels. The built-in routine switch allows of the selection of 9 routine programs. By means of a built-in resistance meter, electrode resistances can be measured, while the internal calibrating signal can be used for recording calibration voltage changes. Recording is made with inkwriting recorders on paper charts. Dimensions : 260 x 61 S X 430 mm

EMG-4753 Four-channel Electro Nystagmograph

The equipment serves for the amplification and recording of spontaneous and brought-about nystagmus. 8 electrodes and 2 earthing electrodes can be connected to the portable, up-to­date design instrument. Resistances of the electrodes can be measured by means of a built-in resistance meter. Signals ampli­fied to an appropriate level are recorded by inkwriting recorders. Dimensions: 260x625x430 mm

Page 29: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-4754

EMG -4755

EMG -4756 8-, 12·, 16-channel Electro Encephalographs

When performing electrophysiological examinations in neuro­

pathology and psychiatry, the equipments can be used for scien·

tific analysis as well as diagnostics. The equ ipments meet all

requirements made with up-to-date encephalographs. Owing to

their high sensit ivity (1 mmf!J.V), low own noise, high immunity

for external disturbing signals, high number of channels and

other special provisions t he equipments can be used for scientific

research in addition to the routine tests. The preamplifiers and

the recorder are designed a.s separate units. The type EMG-4754

has 8, the t ype EM G-4755 has 12. the type EMG -4756 has 16

channels. The construction of the equipments and arrangement

of their units ensure that the operator can sit comfortably .

The preamplifier channels, the common amplification control.

the routine switch and the calibrating unit are designed as plug-in

units. Besides the recorders of the EEG lead the instrument

is provided also with two separate recorders used for recording

the time signals in every second, marker signals as well as for

recording stimulating signals in case of stimulation.

By means of the selector switches, the electrode points and the

indifferent point can be coupled to the input of amplifier channels

in any combination. The plug-in routine switches serve for the

adjustment of 9 routine programs. For separate order, EMG

supplies routine switches allowing of t he adjustment of other

r equired programs. Two polygraph amplifier s with 1 mY sen­

sitivity are bu ilt into the main recorder unit , and can be switched

instead of the two last channels. They ar e suitable for the exa·

mination of the var ious physiological funct ions, intercon necting

the appropriate transducers. There is also a possibility for con­

nection to an oscilloscope. The photostimulators types EMG-4761

and EMG -4764 or phonostimulators types EMG -4762 and EM G-

4763 can also be connected to the equipment.

STIMULATORS

Photo- and phonostimulators ar e an applience for· performing

electrophysiological examinations in neurology, and psychiatry.

Their special field of a pplication is electro encephalography. The

instruments are fu lly transistorized .

EMG-4761 Photostimulator

It is suitable for produci ng light stimuli with adjustable flas h

frequencies . Both the intensity and the colour of the light

stimuli can be altered. The frequency can be adjusted between

2 and SO cfs.

EMG-4762 Phonostimulator

The instrument is capable of producing continuous sound signals

with 5 different frequencies for sound stimuli. Intensity of the

ow d istortion signals can be adjusted.

Page 30: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EMG-4764 Photostimulator

The high-power photostimulator is suitable for producing light

stimuli . It can produce either continuous or intermittent light

beams, as well as single and double light pulses. Duration of the

Intermittent light beams, the interval between double light

pulses and the light energy can be adjusted.

,,.,..,,..,,.,.,,.,,,,,,,,,,,,.,,.,,,.,,,,,,,,,,,.,,,,

.,,.,..,.,.,,.,,..,,,,.,;,,,,,,,,,,,.,.,,,,,,,,,,,,,,

Manufactured by EMG

EMG-4763 Phonostlmulator

The high-power phonostimulator is capable of producing sound

stimuli in the form of continuous sound signals with S different

frequencies, as well as sound signals interrupted with adjustable

frequencies. Intensity of the low distortion signals can be adjusted.

PATIENT MONITORING EQUIPMENT

EMG-4771 Pulse Rate and ECG Monitor

The instrument serves for constant mon itoring of patients' heart funct ion ing at surgical wards and the intensive therapeutics departments. When used as a pulse rate meter, the Instrument indicates the patients' pulse rate on an indicating meter in the range of 20 to 200 pulses per minute. It is suitable to give auto­matic light and sound warn ings when sensing a pulse rate that reaches the preset lower or upper limits. Apart from Indicating t he values related to the patients' heart functioning, the instru­ment also indicates by means of light and sound pulses. The values to be measured can also be recorded by means of a separate recorder. A single-channel ECG preamplifier is also comprised in the instrument. Dimensions: 135 X 436 X 349 mm

WORKS FOR ELECTRONIC MEASURING GEAR Budapest, XVI., Cziriky u. 26-32. HUNGARY Telex: 33-50.

Exported by MEOICOR WORKS Budapest, 62, P.O . Box. 150. HUNGARY

69.2417 Eaecemi Nyomda m61ynyomiu, Budapen (MIJYar Hirdet6)

Page 31: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

.,. ,, ,. '

ELECTRONIC LOGIC CIRCUITS The various logic circuit series are suitable for the construction of automatic digital control systems and data processing equipment. The modules include no moving parts, performing the switching functions solely by means of semiconductors. The modules have long service life practically independent of the number of switching. Their outstanding character istics are high speed of operation, low probability of brea kdown, low power consumption, little space requireme nt . The modules require no maintenance.

: DS-1000 Logic circuit series General specificat ion of the EDS-1000 series :

rated logic voltage leve ls In series EDS-1000 the logic circuits are produced in the form

of "p.c. card" modules. Each module cont ains several independent

circuits r ealizing identical logical function. The modules are

mounted on single-face or double-face printed ci r cuits boards.

The standard 130 x 165 mm modules are fitted with anodized

aluminium frames. The modules may be plugged in various rack

cabinets or stands.

The selection of t he EDS-1000 modules is the following: inverters,

D, DD, Dl, DDI-Iogics, flip-flops , counters, indicators, emitter­

follower, power-amplifiers, matrices, phase maintaining ampli­

fier:>, delay units, generators, integrator and special units.

level ''1":

level "0" :

pulse repetition rate :

operating temperature range :

supply voltages :

- 3 v ov max. 100 kc/s

- 20 °C to +55 °C

-15 V; -3 V;

+ 10 v ± 5%

Stabilized power supply suitable for the operation of the mo­

dules :

EDS-1971 ( - 15 V, 1.5 A; -3 V, 1.2 A; + 10 V, 0.3 A)

Page 32: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EDS-4000 "STATOMAT" series

The series modules find applications in the construction of digital

control units working under hard industrial conditions. Each

module is realizing a single logical function. The circuits are

mounted on small-size printed-circuit boards. The assembled

circuit is protected by a plastic coating and an anodized alumi­

nium casing.

The selection of the EDS-4000 modules is the following: inverters,

D. Dl-logics, flip-flops, multivibrator, switching amplifiers, power

and indica.tor amplifiers, delay unit, pulse shaper, generators,

annunciator, sensors, matrices, and special units.

General specification of the EDS-4000 series :

rated logic voltage levels

level "1":

level ''0":

pulse repetition rate:

operating temperatUre range :

supply voltages :

- 6 to -12 v 0 v max. 2 kc/s

-SO oc to + 55 oc - 12 V; +12 v +20-30%

in addition to the

above the high-power

switching amplifiers

require -48 V or

- 24 V, •·esp.

Power supplies su itable for the ope rati on of the modules are

avai lable in different loading variations :

Stabilized power supp lies:

EDS-4971 (12 V; 0 to 0.5 A)

EDS-4972 (12 V; 0 to 1.5 A)

Unstabilized power supplies:

EDS-4973 (12 V; 0 to 0.3 A)

EDS-4974 (12 V; 0.3 to 1.5 A)

EDS-4975 (12 V; 1.5 to 6 A)

EDS-4976 (24 V; 1.5 to 6 A)

EDS-4977 (24 V; 6 to 15 A)

EDS ..... 978 (48 V; 1.5 to 6 A)

EDS-4979 (48 V; 6 to 15 A)

EDS-5000 ''MINICARD" series

The modules form a compatible system suitable for the construc­

tion and modelling of digital control systems and data processing

equipment. Each module is capable of performing a single logical

function. The circuits bu ilt up of germanium semiconductors

are mounted on 196 X 109 mm epoxy resin p.c. boards. The mo­

dules may be plugged into various 19" rack cabinets, each cabinet

is capable of accommodating 24 modules.

The selection of the EDS-5000 modules is the following: indicator

amplifiers, switching amplifier, power amplifier, inverte rs,

matrices, D, Dl, DD, DOl-logics, flip-flops, counters, Nixie­

driver, Miller delay unit, monoflop unit, generators, Schmitt­

trigger and other special units.

General specification of the EDS-5000 series­

rated logic voltage levels

level "1":

level "0":

pulse repetition rate:

operating temperature range :

supply voltages :

-3 v 0 v max. 100 kc/s

- 20 °C to + 55 °C

- 15 V; - 3 V;

+10 v ± 5%

Stabilized power supply suitable for the operation of the mo­

dules:

EDS-071 1 (-15 V, 0 to 6 A; -3 V, 0 to 5 A; + 10 V, 0 to 1.5 A)

., ~

~ "' STABILISED

PO"'ER SUPPLY UNIT

TV" EDS 4971

• e • ........ RfSfl

()UTPUT

0 .:,..nv ,.,....o 0.5.l

~ -·- 8 _ __.:...;

Page 33: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EDS-8000 "MINICARD" series

The modules of the series are suitable for the construction of high -speed digital control system and ~ata processing equip­ment. The selection of modules is continuous! y developped meeting every requirement. The modules are built of silicon planar epitaxial semiconductors, which ensure high-re liability and wide operating temperature range. Mechanical design of the modules corresponds to that of the EDS-5000 series. The selection of the EDS-8000 modules is the following : power amplifiers, 01, DO, DOl-logics, Nixie-driver, flip-flops, level converter, Miller delay unit, monoflop unit, generator, Schmitt­trigger and other specia l units.

General specification of the EDS-8000 series :

rated logic voltage levels level "1" : level "0": pulse repetition rate: operating temperature range: supply voltages :

+6 v 0 v max. 1 Mcfs - 55 °C to + 100 °C + 24 V. + 8 V;

-10 v ±5%

The voltages necessary for the operat ion of the modules are furnished by a power supply w ith 8 A loadability.

EDS-3000 "MICROCARD" series

The modules of the series are suitable for the construction of digital systems. Owing to the small dimensions of the modules the space requ irements of highly complicated systems built up of numerous modules can be greatly diminished. The modules are built up of germanium semiconductors. Each module Is capable of performing a single logical function. For t he realization of complex functions interconnection of the appropriate modules is necessary. The modules can be mounted on EDS-7000 series mother boards. These are 260x240 mm epoxy resin p.c. boards without a frame. The EDS-7093 board is capable of accommodating 56 modules. The selection of the EDS-3000 modules is the following : indi­cator amplifiers, inverters, 0, 01, DO-logics, matrices, half flip-flop, diode-capacitor-diode gate, Miller delay unit, monoflop, generator, Schmitt-~rigger and other special units. General specification of the EDS-3000 series : rated logic voltage levels level "1": level " 0": pulse repetition rate: operation temperature range: supply voltages :

-3 v 0 v max. 100 kcfs -20 °C to +55 °C - 15 V; - 3 V; +10 v ±5%

Stabilized power supply suitable for the operation of the modules : EDS-0711 .

Page 34: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

EDS-2000 " MICROCARO" ser ie s

The series consists of a full compatible circuit set, suitable for

the construction of even the most complicated digital systems.

The logic circuits are built up of up -to-date silicon planar epi­

taxial semiconductors. Outstanding characteristics of the modules

are high-reliability, wide operating temperature range, high

noise-immunity, high repetition rate, high fan-in and fan-out.

Their mechanical design is identical with that of the EDS-3000

series. The modules are mounted on 25 x 47 mm superpertinax

sheets. The sheets can also be mounted on the EDS-7000 series

mother boards.

Manufactured by EMG

The selection of the EDS-2000 modu les is the following: power amplifier, Dl, DD, DOl-logics, AND extender. half flip-flop, diode-capacitor-diode gate, level converter, counters, matrix, generat or and other specia l uni ts. General specification of the EDS-2000 series : rated logic voltage levels level "1": +6 V leve l "0":

pulse repetition rate: operating temperature range: supply voltages:

0 v max. 1 Mcfs

-55 °C to +100 °C

+ 24 v ± 5% +8 V, - 10 V ±10%

The voltages needed for the operation of the modu les are fur­nished by a power supply with 8 A loadability .

WORKS FOR ELECTRONIC MEASURING GEAR Budapest, XVI., Cziraky u. 26-32. HUNGARY Telex : 33-50,

Exported by METRIMPEX HUNGARIAN FOREIGN TRADING COMPANY FOR INSTRUMENTS Bwapest, 62. P.O.B. 202 Cable : INSTRUMENT, Budapest, HUNGARY

69.1~17 Ecrttomo Nyomda melynyomiu. Budapen IManar Hirdotol

!l

Page 35: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

ELECTR.ONIC DESK CALCULATORS

HUNOR-131 Electronic Desk Calculator

The HUNOR-131 calculator Is designed primarily for performing

the four basic arithmetical operations, with integers or decimal

num bers as well. The calculator can be used for addition, subtrac­

tion, multiplication, division, repeated addition, subtraction of

several identical numbers (items} or raising to power with integer

exponent (repeated multiplication). The calculator has an arith­

metical capacity of 13 digits. The calcu lator features fully electro­

nic design, it includes no moving parts, and it comprises only

semiconductors as active electronic components. It offers ease

of operation, the numerical and operational keys are arranged

suitably in the keyboard. The machine featu res silent operation,

with an electronic rate.

The reliability of calculation is ensured by electronically controlled

automatic light and acoustic signalling and by the electronic

interlocking of the keyboard. Facilities are provided fo r clearing

a spu r iously entered digit or the last row of numbers entered

in the calculator, without interfering with the previous results.

If the result of arithmetical operations performed exceeds 13

digits, the overflow is indicated for the operator by an illumi­

nating sign at the end of the in -line digital display and simulta­

neously, by an acoustic signal.

The field of application can be widened considerably by using

the external keyboards (max. 6), permitting the calculator to

be controlled in a t ime sequence from several places as well.

A numerical printer can also be connected to the calculator,

printing-out automatically on a paper strip the numbers and

operational si&ns appearing on the digital display panel of the

calculator.

HUNOR-157 Multi-keyboard Electronic Calculator

The HUNOR-157 Multi-keyboard Electronic Calculator can be

used to advantage to perform a great variety of operations. The

HUNOR-157 calcu lator can be connected with type HUNOR-158

external keyboards each having a built-in display. Not only one,

but max. -4 such un its can be connected to the machine. This way,

the machine HUNOR-157 -1 58 pe rforms in a sequence the task

of four separate calculators. The layout of the machine meets

all requirements of up-to-date working areas. The calculating,

controll ing parts as well as the registers are accommodated

in the central unit (HUNOR-157}. The elegant design keyboards

having a built-i n display (HU NOR-158) can be coupled to this

central unit. The central unit can be placed at a su itable spot of

the office, while the small-s ize keyboards are placed on the desks.

The calculator is designed primarily to perform the four basic

arith metical operations (addition, subtraction, multiplication,

division). Repeated additio n, subtraction, multiplication (raising

to powers), division can also be made. By using its free registers,

complex operation-sequences can also be performed. The inter­

mediate results of calculations are stored by the machine and are

directly applicable as the first operand of a following operatio n.

The capacity of calculatio n is 15 decimal d igits, this is sufficient

even in the most specific fields of application.

The HUNOR-157-158 offers ease of operation, arrangement of

the numerical and operational keys is advantageous. Operation

is silent and is performed at an electronic rate. The calculator

is fully electronic, containing no moving parts. The active elements

of the calculating unit are all semiconductors, t he registe rs are

built-up of ferrite memo ry cores.

Page 36: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

The reliability of calculation is ensured by electronically controlled

automatic light and acoustic signalling and by the electronic

interlocking of the keyboard. During the calculation significant

digits will not be lost. The number of decimals of the result can

be determined by adjustment of the 16-position decimal-dial

located on the keyboard unit.

The calculator contains three universal registers for forming

and storage of constants, subtotals and the sum of products or

quotients with correct sign and decimal point.

Manufactured by EMG

To the HUNOR.-157 calculator a printer (HUNOR-159) can

also be connected. The prin'ter can be placed at a suitable spot

of the office and can be Interconnected with the central unit by

means of a cable. It prints out the operations performed depending

upon the position of the switch located on the operating key­

board.

The calculator HUNOR-157-158 can be used to advantage to

perform engineering design, business management, statistical

calculations as well as d iverse other appl ications.

WORKS FOR ELECTRONIC MEASURING GEAR lud~pe~t. XVI., Cziriky u. 26-32. HUNGARY TeleK: 33·50.

Exported by MrTIUMPEX HUNGARIAN FOREIGN TRADING COMPANY FOR INSTRUMENTS Budapelt., 62. P.O.B. 2.02 Cable: INSTRUMENT, Budapest, HUNGARY

, I . ,. .

Page 37: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

'

'

DIGITAL ELECTRONIC COMPUTER

EMG-830 Digital Electronic Computer

The EMG-830 digital electronic computer though according to

its technical construction belongs to the category of II. generation

machines, in its logical structure features many Ill. generation

characteristics.

These characteristics facilitate the application of the machine

for data processln1, technical-scientific c~lculations and

process control. Continuous development of the program

library Widens the applicatiOn facilities even after putting tO

operation.

Programming is facilitated by SIMPLE assembler and EMG auto­

code, ALGOL and FORTRAN compilers are under development.

Organization and fast operation of the computer facil itate

multiprogramming and also real-time program run indis­

pensable In process control applications.

The program library consists of :

various sub:outines (activation of peripheral equ ipment)

standard functions

floating point and double word length operations diagnostic test

programs

technical and data processing programs

compilers and Interpretive programs for the above programming

languages.

Application of the computer is greatly helped by the direct con­

tact of EMG Computer Sales Department which is always readily

at customers' disposal.

To make customers acquinted with the machine, EMG organizes I courses for programmers and operators on different levels.

EMG Computer Sales Department helps customers In all ques­

tions concerning operation and installation (e .g. experts advise

_:_

EMCi 830

the user on computer room layout and on adequate enviromental

conditions).

The up-to-date electronic computer bu ilt up of silicon semi·

conductors, owing to its modular construction is suitable for a

wide field of applications. Th is means, that accord ing to new

requ irements the performance of the computer might be In·

creased by simply plugging-In additional modules (without

changing the original machine construction). If, for instance,

the problems at the very begining might be solved by a small

configuration consisting of only a few modules, the possible

later extension should be taken account only from the aspect

of space requirements.

The EMG-830 us a single address machine. Wordlength is 2~

bits In case of a data processing variation and 21 +3 bits in case

of process control variation. In the latter case the separated 3

bits serve for parity check which ensures increased safety of

operation indispensable in process control applications.

The instruction format ensures direct addressing of 32,768 store

locations in case of data processing and 8,192 store locations in

case of a process control variation. In other words, the ferrite

care store can be extended with ~K modules up to 32K capacity

in case of a data processing variation and up to 8K in case of a

process control variation.

For the storage of wired programs the Internal store might be

extended with 256 word permanent store modules. Cycle time

of the operative (f!!rrite core) store is 6 !J.S, average speed of the

machine is 25,000 operations per second.

Page 38: ORION EM G · Phase shift: Accuracy of phase shift: Amplitude of the output signal: Dimensions: 0.0005 to 1,110 cjs 0 to 360° ±2% 0 to 10 Vrms 2-40x500x 385 mm The Instrument contains

6-4 input or output peripherals can be connected to the machine

each having an identical internal standard interface unit. Several

backing stores e .g. maanetic tape, magnetic disc, etc. can be

connected to the machine.

Selection of the applied peripheral equipment always depends

upon the particular needs of the customer. The necessary inter­

face units are always supplied by EMG.

Standard peripheral selection includes the following e .g . :

FS 1500 tape reader

PE 1501 FACIT tape punch

IBM 731 on-line typewriter

BULL S-41 200 llnesfminute line printer

BULL 557 600 lines/ minute line printer

Back ina s~ores :

Manufactured by EMG

PEN 5 D SPERAC IBM compatible magnetic tape memory

MD 17 SPERAC magnetic disc (capacity approx. 58 million bits)

MS 300 SA GEM magnetic disc (capacity : 2, 4 or 8 million bits)

For a special request, any peripheral equipment, data link or

satellite computer (compatible with the EMG machine) might

a lso be connected to the mach ine, EMG providing the necessary

interface units.

The computer ha.s 64 input-output peripheral interface channels,

further equipment might be connected by inserting multiplex

units.

There Is no restriction for the maximum number of one type

of peripherals it is limi ted only by the available channels and

o rganizational aspects.

I

WORKS FOR ELECTRONIC MEASUP.ING GEAR Budapest, XVI., Czlliky u. 26-31. HUNGARY Telex: 33-50.