Original installation instruction, operating instruction

Page 2: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

V01 03/2012 - 2 -

Safety instructions

Warning!Wrong installation, service, maintenance or cleaning as well as unauthorized changes on the unit can cause damages, injuries or even death. Read the installation manual carefully before installing the unit.This unit may only be used for preparing food in commercial kitchens. Every other usage is against definition and therefore dangerous.

Warning!Only gas units- As the unit must be installed underneath an extraction hood, it must be made sure that

the hood is switched on during operation of the unit – exhaust gases!- Don't put any material on the exhaust pipes of the unit – Fire hazard!- The area underneath the unit may not be blocked or closed by any material– Fire hazard!- The unit may only be operated in a calm environment – Fire hazard!

Safety measures in case of smell of gas:- Immediately close the gas supply.- Don't touch any electrical switching element- ventilation of the room.- Avoid open flame or sparks- Use an external telephone and inform your local gas authority (in case the local gas

authority can not be reached contact your local fire department immediately).

- The appliance may only be moved on surfaces with a maximum slope of 10°. It must be made sure that the required displacement respectively retarding force, depending on the current unit weight, can be sustained at any time.

- The appliance may only be moved by a maximum of 2 persons.- When using the handle of the trolley, which can be pushed in the base frame of the unit,

the unit may only be moved on horizontal or slightly slope surfaces (unit does not move without pushing).

- When pushing the unit, especially on slope surfaces and for securing it during change of direction it is not allowed to push or pull on the door handle respectively control panel.

Page 3: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

- 3 - V02 12/2011

Safety instructions

Danger! Immediate dangerous situ-ation, that can endanger and cause severe injury or death

Corrosive substances

Attention: Not following the instruction can cause material damages.

Warning! Possibly dangerous situ-ation, that possibly can endanger and cause severe injury or death.

Fire hazard!

Tips and tricks for instal-lation

Attention! Possibly dangerous situ-ation, that can endanger and cause minor injury.

Danger of burning!

Danger!High voltage. Caution danger of lifeNot following the instruc-tion can endanger and cause severe injury or death.

Explanations of the icon's

FOR YOUR SAFETYDo not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

Page 4: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

V01 03/2012 - 4 -

Safety instructions 2Safety instructions 3Table of content 4Mobile floor models 20x1/1GN and 20x2/1GN 5Connection data USA/Canada 11Schematic drawing 20x1/1 GN Electric, mobile 12Schematic drawing 20x1/1 GN Gas, mobile 13Schematic drawing 20x2/1 GN Electric, mobile 14Schematic drawing 20x2/1 GN Gas, mobile 15

Table of content

Page 5: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

- 5 - V01 03/2012

When moving the unit the following must be observed:1. Don`t push at the operator panel. This can

destroy the control unit behind it.

2. Don`t pull the unit using the door handle, this can damage the door lock mechanism.

Prior to the transport of the unit observe the following procedure:1. Read installation and/or user manual.

2. Disconnect all supply lines at the unit to avoid damages.

3. Move unit only by using the handle

Mobile floor models 20x1/1GN and 20x2/1GNAttention:The following warning stickers are affixed to the unit:

Sticker:"Don't push on operator panel"

Sticker:"Don't pull on door han-dle"

Sticker:Observe before transport of unit

Page 6: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

V01 03/2012 - 6 -

Mobile floor models 20x1/1GN and 20x2/1GN

When moving the unit the power cord must be secured against damage, therefore at the top rear side of the unit the enclosed holding device must be installed.- Undo the tapping screw at the left rear side and fasten the holding device with the

screw to the top cover.

Sticker:"Danger of tipping over"

Sticker:"Danger of tipping over"

Sticker:"Attention: For taking the unit off of the pallet at least 2 persons are required"

Sticker:"Attention: For taking the unit off of the pallet at least 2 persons are required"

Sticker:"Standards for mobile gas units"

Page 7: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

- 7 - V01 03/2012

Mobile floor models 20x1/1GN and 20x2/1GNFor taking the unit off of the pallet see next page.

For transport of the unit with or without pallet the following minimum measures have to be observed:With pallet width height20x1/1GN 37 1/8" 78 3/8"20x2/1GN 45 3/8" 78 3/8"Without pallet width height20x1/1GN 35 3/4" 72 1/2"20x2/1GN 44 1/8" 72 1/2" pic. 1

Attention: The unit may only be moved / transported when it is switched off and all supply lines are disconnected. When moving the unit take the trolley out of the cooking cabinet.

For pulling the unit out of the site, in case there is not enough space at the left or right side:- Cool down the unit below 100°F- Open cabinet door- Pull at the interior cabinet. pic. 2

AttentionWhen pulling the unit out of the site the door can close accidentally. Crushing hazard! For transport of the unit:a) Empty steam generator. Procedure see

operator manual. b) Disconnect water supply, drain and

additionally on gas units the gas supply line at the connection points of the unit.

c) Only exception is the power cord installed in electric and gas units. The units can be connected with plug. In this case, for transport, the power cord must be protected against damage by hooking it up in the holding device at

the rear side of the unit pic. 3

20x1/1 GN:940mm/37 1/2"

20x2/1 GN:1150mm/45 1/4"

1

3

2

Page 8: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

V01 03/2012 - 8 -

Mobile floor models 20x1/1GN and 20x2/1GN

4

- The unit is delivered on a special trans-port pallet. This pallet can be used sev-eral times. Therefore don't dispose the

pallet. pic. 1

Attention: To avoid injuries make sure that always two persons are available for taking the unit off of the pallet. Crushing hazard!

For rolling the unit off the pallet, proceed as follows:a) There are rails stored on the pallet

underneath the unit. Fix these rails to the right side of the pallet using the enclosed screws (screw driver 13 mm)

pic. 2b) Remove the retaining bracket at the left

and right side of the base frame of the unit by loosing the corresponding

screws (screw driver 19 mm). pic. 3 c) Stick the handle, which is enclosed in

the scope of delivery (handle of the trolley) into the holes of the right base frame. Take trolley out of the cooking cabinet and roll the unit down from

the pallet. pic. 4d When using the pallet again for trans- When using the pallet again for trans-

portation fix the unit to the pallet using the retaining brackets and the corre-sponding screws.

For moving the unit the handle of the trol-ley can be used. Stick the handle either in the right or the left openings of the base frame. pic. 55

1

2

3

Page 9: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

- 9 - V01 03/2012

Mobile floor models 20x1/1GN and 20x2/1GN- Minimum space of 50 mm (2") at the

left, right and rear side of the unit must be maintained. For connecting power, gas and water we recommend a space of 500 mm (20") at the left side of the unit. At sites where not enough space is available make sure, that all supply lines are long enough for moving the unit that far forward that the supply lines can be

connected and disconnected. pic. 1

Attention: External Heat Source Proximity: Each Combi-Steamer must be clear of all external sources of heat · Increased appli-ance temperature may cause damage to unit components · Installations must comply with all local electrical, plumbing and ventilation codes · RATIONAL rec-ommends water treatment based on the results of water testing · Consult owners manual for additional installation require-ments.

- The floor at the site must be level. A height adjustment of the unit is not pos-sible.

- The unit must be secured at the site by pressing the brakes of the casters. pic. 2- Additionally the unit is equipped with fixing plates pic 3

These plates can either be glued to the floor with a special adhesive or with screws and dowels. Screws and dowels are not included in the scope of delivery. Run the unit onto these plates. Secure the unit with the slider and fasten the slider with the nuts.

- Trolley must stand level inside the unit. Attention: Observe height of the drain.

Attention:An incorrect levelled trolley can cause malfunction during operating the unit (e. g. during Cleanjet)

3

2

5006.0213

ca. 8

00 m

map

pox.

31”

1

Page 10: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

V01 03/2012 - 10 -

Mobile floor models 20x1/1GN and 20x2/1GN- Additionally the unit must be secured

against slipping by a chain or cable in order to prevent damage to the electric-ity or gas supply line. Therefore a hole is in the left frame at the rear side for

connecting the chain or cable. pic. 1/2

AttentionRestraint cable must be shorter than water, gas and electric supply lines Applicable Standards:- American National Standard Institute/

Canadian Standards Association (ANSI Z21.69/CSA 6.16) 2005 Revision/Publication Fall 2005

- National Fuel Gas Code (ANSI Z223.1/NFPA 54) Adopted, Fall 2005 Version

- CSA International - B149.1 Natural Gas Installation Code Current Version

1. Electric connectionObserve your local regulations!Basic hints and colour coding of the wires see pages 14 and 15.Electric units:• Each appliance requires an independent

fused power supply line• The units 20x1/1 GN and 20x2/1 GN

aredelivered without power cord and without plug.

• The connection terminals are located in the electric compartment. To get access open left side panel (remove the two

brackets) pic. 3Gas units:• We recommend an independent fused

power supply line for each unit.• The units are delivered with a power

cord approx 8 ft long without plug.• To get access to the terminals open left

side panel (remove the two brackets). pic. 32. For drain connection we suggest to

have a floor drain at the rear left side of the unit. In this case a drain pipe with elbow piece can be connected to the unit. The pipe should have a clear out-flow (air gap) of 1” above the floor

drain pic. 4

3

4

1

2

Wall

Supply lines

Page 11: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

- 11 - V01 03/2012

Connection data USA/Canada

Electric units: Power kW Running Amps 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/12 AC 208V 11,1 53,42 AC 240V 11,1 61,53 AC 208V 11,1 22,1 19 37 38 68 30,8 61,4 52,8 102,7 105,6 1893 AC 240V 11,1 22,1 19 37 38 68 35,5 70,8 60,9 118,6 121,8 2183 AC 440V 11,1 22,1 19 37 38 68 14,6 29 24,9 48,6 49,9 83,93 AC 480V 11,1 22,1 19 37 38 68 15,8 31,5 27 52,6 54 96,7

Fuse = A AWG 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/12 AC 208V 60 #42 AC 240V 70 #43 AC 208V 35 70 60 125 125 200 #8 #3 #4 #2 #1 4/03 AC 240V 40 80 75 150 150 250 #8 #3 #4 #2 #1 3/03 AC 440V 20 35 30 60 60 100 #14 #8 #8 #4 #4 #23 AC 480V 25 40 35 70 70 110 #14 #8 #8 #4 #4 #3

Gas units: Electrical connection Power kW Running Amps 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/1 6x1/1 6x2/1 10x1/1 10x2/1 20x1/1 20x2/11NAC 120V 0,4 0,5 0,95 3,33 4,17 7,92

Single Phase208V 0,4 0,77 0,5 0,8 0,95 1,6 1,92 3,7 2,4 3,85 4,57 7,69240V 0,4 0,77 0,5 0,8 0,95 1,6 1,67 3,21 2,08 3,33 3,96 6,67

• Use copper wire only for power supply connections• The maximum allowable tolerance of the supply voltage (supply

voltage see name plate) is in the range of -15% up to +10%

Note: 120V comes with 5-15P Cord & Plug

Note: 208V & 240V with 6-15P Cord & Plug

Page 12: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

V01 03/2012 - 12 -

Schematic drawing 20x1/1 GN Electric, mobile

148758-1/2 []

1254-7/8 []1505-7/8 []

70727-7/8 []

931

36-5/

8[

]10

1840

-1/8

[]

879

34-5/

8[

]

1237

49[]

44517-1/2 []1978[]

791

31-1/

8[

]50

2 []

847

33-3/

8[

]

562-1

/4[

]

738

29[]

min.

- max

. 810

[7/8]

666

26-1/

4[

]36

1-3/8

[]

562-1

/4[

]

199

8[]

471-7/8 []

905

36[]

mm [inch]

abne

hmba

rde

moun

table

Page 13: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

- 13 - V01 03/2012

Schematic drawing 20x1/1 GN Gas, mobile

931

36-5/

8[

]

1023

40-1/

4[

]

879

34-5/

8[

]

1254-7/8 []

1252

49[]

200

8[]

471-7/8 []

44517-1/2 []

1988[]

791

31-1/

8[

]50

2 []

min.

666

26-1/

4[

]

738

29[]

847

33-3/

8[

]

905

36[]

mm [inch]

562-1

/4[

]

562-1

/4[

]

361-3

/8[

]

1505-7/8 []

100739-5/8 []

178770-3/8 []

863-3

/8[

]

303

12[]

320

12-5/

8[

]

873-3/8 []

1104[]

1766-7/8 []

abne

hmba

rde

moun

table

Page 14: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

V01 03/2012 - 14 -

Schematic drawing 20x2/1 GN Electric, mobile 10

8442

-5/8

[]

1131

44-1/

2[

]12

2348

-1/8

[]

1505-7/8 []1254-7/8 []

996

39-1/

4[

]50

2 []

562-1

/4[

]

195

7-5/8

[]

491-7/8 []

1443

57[]

48719-1/8 []26010-1/4 []

min.

- max

. 849

[33-1

/2]77

730

-5/8

[]

849

33-3/

8[

]10

5241

-3/8

[]

1119

44[]

361-3

/8[

]

145

5-3/4

[]

178770-3/8 []100739-5/8 []

mm [inch]

abne

hmba

rde

moun

table

Page 15: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

- 15 - V01 03/2012

Schematic drawing 20x2/1 GN Gas, mobile

mm [inch]

502[

]99

639-1/4

[]

562-

1/4

[]

min.

777

30-5

/8[

]

1119

44[]

1052

41-3/8

[]

849

33-3

/8[

]

361-

3/8

[]

145

5-3/

4[

]

1131

44-1

/2[

]1223

48-1

/8[

]

1254-7/8 []1505-7/8 []

100739-5/8 []

178770-3/8 []

1084

42-5

/8[

]

26010-1/4 []

48719-1/8 []

1445-5/8 []491-7/8 []

1275[]

1977-3/4 []

1452

57[]

863-

3/8

[]

195

7-5/

8[

]27

911[

]29

812[

]

abnehmbar

demountable

Page 16: Original installation instruction, operating instruction · 2017. 10. 11. · 2005 Revision/Publication Fall 2005 - National Fuel Gas Code (ANSI Z223.1/ NFPA 54) Adopted, Fall 2005

80.05.306 · V-01 · Technical Services · Dja· 03/2012

USA