open cooling towers s1500e · open cooling towers. s1500e. installation instructions. 2. eu notes....

16
R ACC S1500E v00 EN Options & accessories Open cooling towers S1500E INSTALLATION INSTRUCTIONS

Upload: others

Post on 15-Mar-2020

12 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

R ACC S1500E v00 EN

Options & accessoriesOpen cooling towersS1500E

INSTALLATION INSTRUCTIONS

Page 2: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

2W W W . B A L T I M O R E A I R C O I L . E U

Notes

Page 3: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

3W W W . B A L T I M O R E A I R C O I L . E U

Table of contents

4 Safety precautions

5 Bottom water outlet / Equalizer / Remote Sump

Internal sliding service platform

7 Accesstofillpack

8 Internal service platform

Internal ladder only

9 External ladder and railing on top of hot water basin

9 Ladder10 Handrail

10 Discharge attenuation

10 Single discharge atttenuation11 Double discharge attenuation

11 Intake attenuation

11 Singlestackunit12 Doublestackunit

13 Motor davit

14 Shipped loose fan cowl

15 Further assistance and information

Page

Page 4: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

4W W W . B A L T I M O R E A I R C O I L . E U

Safety PrecautionsAllelectrical,mechanicalandrotatingmachineryconstituteapotentialhazard,particularlyforthosenotfamiliarwithitsdesign,constructionandoperation.Accordingly,adequatesafeguards(includinguseofprotectiveenclosureswherenecessary)shouldbetakenwiththisequipmentbothtosafeguardthepublic(includingminors)frominjuryandtopreventdamagetotheequipment,itsassociatedsystemandthepremises.Ifthereisdoubtaboutsafeandproperrigging,installation,operationormaintenanceprocedures,contacttheequipmentmanufacturerorhisrepresentativeforadvice.Whenworkingonoperatingequipment,beawarethatsomepartsmayhaveanelevatedtemperature.Anyoperationsonelevatedlevelhavetobeexecutedwithextracaretopreventaccidents.

AUTHORIZED PERSONNELTheoperation,maintenanceandrepairofthisequipmentshouldbeundertakenonlybypersonnelauthorizedandqualifiedtodoso.All

suchpersonnelshouldbethoroughlyfamiliarwiththeequipment,theassociatedsystemsandcontrolsandtheproceduressetforthinthis

andotherrelevantmanuals.Propercare,proceduresandtoolsmustbeusedinhandling,lifting,installing,operatingandrepairingthis

equipmenttopreventpersonalinjuryand/orpropertydamage.

MECHANICAL SAFETYMechanicalsafetyoftheequipmentisinaccordancewiththerequirementsoftheEUmachinerydirective.

Dependinguponsiteconditionsitalsomaybenecessarytoinstallitemssuchasbottomscreens,ladders,safetycages,stairways,access

platforms,handrailsandtoeboardsforthesafetyandconvenienceoftheauthorizedserviceandmaintenancepersonnel.Atnotimethis

equipmentshouldbeoperatedwithoutallfanscreens,accesspanelsandaccessdoorsinplace.Whentheequipmentisoperatedwitha

variablefanspeedcontroldevice,stepsmustbetakentoavoidoperatingatorneartothefan’s«criticalspeed».

FormoreinformationconsultyourlocalBACBalticarerepresentative.(www.baltimoreaircoil.eu)

ELECTRICAL SAFETYEachfanandpumpmotorassociatedwiththisequipmentshouldbeinstalledwithalockabledisconnectswitchlocatedwithinsightofthe

equipment.Noserviceworkshouldbeperformedonornearthefans,motor,drivesorinsidetheequipmentunlessfanandpumpmotors,

heatersetc.areelectricallyisolated.

LIFTING

CAUTION

FAILURETOUSEDESIGNATEDLIFTINGPOINTSCANRESULTINADROPPEDLOADCAUSINGSEVEREINJURY,DEATHAND/

ORPROPERTYDAMAGE.LIFTSMUSTBEPERFORMEDBYQUALIFIEDRIGGERSFOLLOWINGBACPUBLISHEDRIGGING

INSTRUCTIONSANDGENERALLYACCEPTEDLIFTINGPRACTICES.THEUSEOFSUPPLEMENTALSAFETYSLINGSMAYALSOBE

REQUIREDIFTHELIFTCIRCUMSTANCESWARRANTITSUSE,ASDETERMINEDBYTHERIGGINGCONTRACTOR.

LOCATIONAllcoolingequipmentshouldbelocatedasfarawayaspossiblefromoccupiedareas,openwindowsorairintakestobuildings.

CAUTIONEACHUNITSHOULDBELOCATEDANDPOSITIONEDTOPREVENTTHEINTRODUCTIONOFDISCHARGEAIRINTOTHE

VENTILATIONSYSTEMSOFTHEBUILDINGONWHICHTHEUNITISLOCATEDORTHOSEOFADJACENTBUILDINGS.

FordetailedrecommendationsonBACequipmentlayout,pleaseseetheBACApplicationHandbookEUEdition,

theBACwebsite:www.baltimoreaircoil.euorcontactyourlocalBAC-BalticareRepresentative.

LOCAL REGULATIONSInstallationandoperationofcoolingequipmentmaybesubjectoflocalregulations,suchasestablishmentofriskanalysis.Ensure

regulatoryrequirementsareconsistentlymet.

Page 5: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

5W W W . B A L T I M O R E A I R C O I L . E U

Back-upplateisfactoryinstalled Alignrubbergasketandbottomconnection.

InstallM8hardware

Pre-installedplatformbaseandladder

Bottom water outlet / Equalizer / Remote sumpThebottomconnectioninstallation,istypicalforallbottomoutlets,equalizerandremotesumpconnections.Bottomconnectionpartsareshippedloose.

Internal sliding service platformTheslidingplatformbaseandplatformladderisfactoryinstalled.Thehandrailsystemrequiresfieldinstallation.Thehandrailverticalpostsdropintopre-installedbracketsinaspecificconfigurationdependingonthesizeoftheunit.

Page 6: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

6W W W . B A L T I M O R E A I R C O I L . E U

Drophandrailverticalpostsintothepre-installedbrackets

Handrailconfigurationdependingonunitsize

Slideinthehorizontaltubesintotheverticalposts,securewithhardwareinstalledinverticalpost

SecuretheverticalpostsineachbracketusingM12

boltsprovided.Gateispre-weldedtooneofthevertical

posts.

Page 7: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

7W W W . B A L T I M O R E A I R C O I L . E U

Access to fill packTheInternalSlidingPlatformcanbeusedtoaccessthefillpack,followthenextstepstomovetheslidingplatformtothefillside.

Remove the access ladder by removing the two M12

bolts.

Remove the M10 securing hardware on each side of the

platform.

Removethehandrailandverticalposts. Slidetheplatformtothefillsideandsecureagainwith

M10harware.

AssembleaccessladderwithtwoM12bolts. Installtheverticalpostsandhandrail.

Nowtheplatformcanbeusedtoaccessthefillpack.

Page 8: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

8W W W . B A L T I M O R E A I R C O I L . E U

Pushupwardsononesideofthegridto

open

Slidethegridsideways. Makesurethegridissecuredbyslidingit

totheendposition(lockinplace).

Dependingonmodeltheinternalladderissuppliedintwoparts.Onlyinthiscase,slidethetwohalfladdersintothepre-installedU-channels.

Internal service platform (full area) (only for S15E xxxx-11xE and S15E xxxx-12xE units)

InstallboltsM10 Lifttheladderintoplaceanddropthepre-weldedbolts

intothemountingholesintheuppersupportchannel.

Nofurtherfasteningisrequired.

Note:Theladdercanalsobeorientedtowardsthefillpack(similarprocedure).

Internal ladder only

TheInternalServicePlatform(fullarea)andaccessladderisfactoryinstalled,nofieldinstallationisrequired.Theplatformcanbeaccessedbyopeningtheslidinggrid.

CautionAlways close the sliding grid when standing on the platform.

Page 9: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

9W W W . B A L T I M O R E A I R C O I L . E U

External ladder and railing on top of hot water basinTheexternalserviceladder,cageandthehandrailareshippedloose.

Unitwithinstalledladderandrailing

Externalladderbracketsarefactoryinstalled. Lifttheladderandcageintoplace.

FastenladderbracketswithM12hardware.

Ladder

BOTTOM MIDDLE TOP

Page 10: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

10W W W . B A L T I M O R E A I R C O I L . E U

Allchannelsandbracketsarefactoryinstalled. Installallverticalposts.

Slideinhandrailsandtightenwithsetscrews.

Handrail

Tighten with M10 hardware

Discharge attenuation

Single discharge attenuation

Lift single discharge attenuator onto the

pre-installedfancowls.

Alignthe4L-bracketswithpre-installed

plates.FastenwithM10hardware.

Page 11: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

11W W W . B A L T I M O R E A I R C O I L . E U

Double discharge attenuation

Lift double discharge attenuator onto

thepre-installedfancowls.

Alignthe4L-bracketswithpre-installed

plates.

FastenwithM10hardware.

Intake attenuationSingle stack unit

Lifttheintakeattenuatorontothesteelorconcretesupportstructure.

Theshippingstrapdiagonalscanberemovedafter

installationMakesuretheintakeattenuatorattachmentholesline

upwiththeunitholes.Securewithtappers.

Page 12: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

12W W W . B A L T I M O R E A I R C O I L . E U

Double stack unit

Liftthelowerintakeattenuatorontothesteelorconcretesupportstructure.Makesure

theintakeattenuatorattachmentholeslineupwiththeunitholes.

Lifttheupperintakeattenuatorontothe

lowerintakeattenuator.Makesurethe

intakeattenuatorattachmentholeslineup

withtheunitholes.

Securewithtappers.

Securewithtappers. Theshippingstrapdiagonalscanbe

removed after installation

Note:formodelS15Exx18-xxE,theintakeattenuatorconsistsoftwosectionsforasinglestackunitandfoursectionsforadoublestackunit.Thesesectionsneedtobefastenedinthemiddle

pre-installedchannelsatairintake.

Page 13: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

13W W W . B A L T I M O R E A I R C O I L . E U

Motor davit

Motordavitsupportbracketsarepre-installedinthe

factory.Thedavitsocketisshippedloose.

Installonebolt&nutfacingupondoorsideofthesocket.

FastendavitsocketwithM10hardwaretopreinstalled

brackets.

Attachthedavitsocketateachmotorlocation.

Hookontobottomflangeoffandeckandsecuresocketto

pre-installedbracketsonunit.

Thehookplateisprovidedtosupportweightofsocket

duringinstallationonly.

Slideindavitarm.

Page 14: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

14W W W . B A L T I M O R E A I R C O I L . E U

Shipped loose fan cowl (only on single stack units with WQ fan)

Liftasinglefancowlwithfanguardontothetwofactoryinstalledfancowls.Eachfan

shouldhavestackop3cowlsontopofeachother.

Aligntheholepatternandtightenwith

tappers

Page 15: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

15W W W . B A L T I M O R E A I R C O I L . E U

Further assistance & information

BALTICAREBAChasestablishedaspecializedindependenttotalcarecompanycalledBalticare.TheBACBalticareofferinginvolvesallelementsrequiredtoensureasafeandefficientoperationofyourevaporativecoolingproducts.Fromafullrangeofriskassessmenttoselectivewatertreatment,training,testing,recordkeepingandannualsystemoverview.Formoredetails,contactBACBalticareatwww.balticare.comoryoucanalsocontactyourlocalBACrepresentativeforfurtherinformationandspecificassistanceatwww.BaltimoreAircoil.eu.

MORE INFORMATION

REFERENCE LITERATURE• Eurovent9-5(6)RecommendedCodeofPracticetokeepyourCoolingSystemefficientandsafe

Eurovent/Cecomaf,2002,30p.• GuidedesBonnesPratiques,LegionellaetToursAéroréfrigérantes.Ministèresdel’Emploietdela

Solidarité,Ministèredel’EconomiedesFinancesetdel’Industrie,Ministèredel’Environnement,Juin2001,54p.

• VoorkomLegionellose.MinsterievandeVlaamseGemeenschap.December2002,77p.• Legionnaires’Disease.TheControlofLegionellaBacteriainWaterSystems.Health&Safety

Commission.2000,62p.• HygienischeAnforderungenanraumlufttechnischeAnlagen.VDI6022.

INTERESTING WEB SITESwww.BaltimoreAircoil.eu;www.Balticare.com;www.eurovent-certification.com;www.ewgli.org;www.ashrae.org;www.uniclima.org;www.aicvf.org;www.hse.gov.uk

Page 16: Open cooling towers S1500E · Open cooling towers. S1500E. INSTALLATION INSTRUCTIONS. 2. EU Notes. 3. Table of contents. 4 Safety precautions ... For detailed recommendations on BAC

COOLINGTOWERS

CLOSEDCIRCUITCOOLINGTOWERS

ICETHERMALSTORAGE

EVAPORATIVECONDENSERS

HYBRIDPRODUCTS

PARTS&SERVICES

www.Balt imoreAircoi l .eu

info@Balt imoreAircoi l .eu

www.balt icare.com

info@balt icare.com

BaltimoreAircoilInt.nv,Industriepark-ZoneA,B-2220Heist-op-den-Berg,Belgium

© Baltimore Aircoil International nv

Pleaserefertoourwebsiteforlocalcontactdetails.