omnialog data acquisition systems · wireless monitoring system wr log wireless monitoring system...

13
WR_LOG _ WR LOG WIRELESS MONITORING SYSTEM READOUT UNITS AND DATALOGGERS

Upload: others

Post on 02-Apr-2020

19 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

CRDWR_LOG

_ WR LOGWIRELESS MONITORINGSYSTEM

READOUT UNITSAND DATALOGGERS

Page 2: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 2www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOG

WR LOGWIRELESS MONITORING SYSTEM

WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway communicating with nodes through long range radio. Nodes are configured through an Android APP while the gateway have a web server on-board for the set-up.

WR LOG is a low power consumption system that can reach up to 10 years battery life. Distance between node and gateway can arrive up to 15 km.

The gateway can push data on a FTP server; remote connection to gateway is allowed for data download and set-up.

FEATURES• Long-range communication

of over 15km

• Truly low-power, 10 years of unattended runtime

• Wireless LPWA communication

• Supports most structural and geotechnical instruments

• User-friendly web software

BENEFITS• Remotely monitor

hard-to-access infrastructures

• Cover a wide area with geotechnical sensors

• Easily add sensors to extend measurement range

• Save resources through fast implementation

• Diminish risks and make operations safer

Meet the essential requirements of the EMC Directive 2014/30/EU and RED directive 2014/53/EU

Page 3: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 3www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOG

HOW IT WORKS

SENSORS

INTERNET INTERNET

WIRELESS NODECONFIGURATION

WIRELESS NODE

GATEWAY INDUSTRIAL SERVER

USER’SDEVICE

NETWORKMANAGEMENTSOFTWARE

DATAMONITORINGSOFTWARE

GATEWAY0LSWR000GW0

BASE STATION

Band (1)

Antenna

GPS module

GPS antenna

POWER

Mains power supply

Nominal

DC power supply

NETWORK INTERFACES

Ethernet

Modem

ISM Sub 1 GHz, sensitivity down to -137 dBm

868 MHz ISM band (0LSWR868GW0)915 MHz FCC ISM band (0LSWR915GW0)915-928 MHz ISM band (0LSWR923GW0)

Detachable omnidirectional 1/2 dipole

GNSS high sensitivity

Integrated

Product code 0LSWRGW2200

3 Watts

11 to 30 Volts

10/100 Ethernet WAN (RJ45 PoE) (LAN cable not included)

3G quad band (HSDPA, EDGE, GPRS)

TECHNICAL SPECIFICATIONS

The gateway receive readings from the nodes and push data through the internet to a server for management and visualization. The gateway needs to be supplied with main power supply.

PHYSICAL FEATURES

Overall Dimensions

Weight

IP class

Housing material

Operating temperature

210x310x170 mm incl. mounting kit

2 kg

IP67

Polycarbonate

-20°C to +60°C

(1) For more information regarding how to choose the right Gateway band, see FAQ #089 on our web site www.sisgeo.com

Page 4: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 4www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOG

VIBRATING WIRE NODES0LSWR1CHVWS/0LSWR5CHVW0

PHYSICAL FEATURES

The vibrating wire nodes are able to manage 1 or up to 5 vibrating wire instruments such as piezometers, crack meters, strain gauges, etc...It has an embedded barometer useful for piezometers’ data compensation.Examples of application are column of multipoint piezometers, 3-D crack meters, rosette-mounting strain gauges, multipoint extensometers.Batteries are not included with the node and shall be ordered separatelly.

Number of channels

Sampling rate

Internal data storage

Time synchronization by radio

Power supply

VIBRATING WIRE INPUT

Measurement method

Excitation wave

Measurement range

Resolution (-40 to +85ºC)

Accuracy (-40 to +85ºC)

THERMISTOR INPUT

Measurement range

Resolution

Accuracy (20ºC) EMBEDDED BAROMETER

Pressure Range

Relative Accuracy (950 to 1050 hPa at 25ºC)

Box Dimensions (WxLxH) 1 channel node 5 channels node

Overall Dimensions without antenna (WxLxH) 1 channel node 5 channels node

External antenna

Housing material

IP class

Operating temperature

1 or 5 (vibrating wire + thermistor)

30 seconds to 1 day

Up to 72500 readings incl. time and 5 sensorsUp to 200000 readings incl. time and 1 sensor

time discipline better than ±10 seconds

1 CH: 1 x C-size 3.6 V high power battery5 CH: from 1 to 4 x C-size 3.6 V high power batteries

Embedded algorithms increasing immunity to noise

±5 V

300 to 7000 Hz

0.12 Hz

0.018 % FS

0 ohm to 4 Mohm

1 ohm

0.05ºC (0.04% FS)

300 to 1100 hPa

±0.12 hPa

100x100x61 mm100x200x61 mm

140x120x61 mm140x220x61 mm

114 mm length (including connector)

Alluminium alloy

IP67

-40°C to +80°C

1 CH, sampling 5 min, 1 x battery

1 CH, sampling 30 min, 1 x battery

5 CH, sampling 5 min, 1 x battery

5 CH, sampling 5 min, 4 x batteries

5 CH, sampling 30 min, 1 x battery

5 CH, sampling 30 min, 4 x batteries

(1) considering laboratory condition

3 years

7 years

1.5 years

5 years

4 years

>10 years

TECHNICAL SPECIFICATIONS

BATTERY LIFE ESTIMATION(1)

Page 5: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 5www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOGANALOG NODE 0LSWR4CHANL0Analogue nodes are able to manage up to 4 instruments with different output such as Volts, current loops (mA), potentiometers, Wheatstone bridges, thermistors and PT100. Each channel can be individually configured by the user and the power supply to the sensors is given by the node.Batteries are not included with the node and shall be ordered separatelly.

Number of channel

Sampling rate

Internal data storage

Time synchronization by radio

Instruments power supply

Power supply

INSTRUMENT INPUTS

Voltage measuring ranges

Voltage accuracy (-40 to +85ºC)

Current loop measuring range

Curent loop accuracy (0 to +50ºC)

Potentiometer accuracy (0 to +50ºC) Wheatstone bridge accuracy (0 to +50ºC)

Thermistor accuracy (0 to +50ºC)

PT -100 accuracy (20ºC)

Warm-up time

1 channel, sampling 5 minutes

1 channel, sampling 6 hours

4 channels, sampling 5 minutes

4 channels, sampling 6 hours

Current @ 12 V @ 24 mA

1 seconds

6 months

>10 years

1.5 months

8 years

Current @24 V @24 mA

1 seconds

4 months

>10 years

39 days

6.5 years

Voltage @ 12 V @ 24 mA

1 seconds

5 months

>10 years

2 months

>10 years

Full Wheatstone bridge@ 5 V @ 0.7 kΩ

-

1.5 years

8.5 years

1.5 months

8.5 years

Potentiometer @ 5 V @ 1.5 kΩ

-

1.5 years

>10 years

7 months

>10 years

4 (individually configurable by the user)

30 seconds to 1 day

Up to 200000 readings incl. time and 1 sensor)Up to 72500 readings incl. time and 4 sensors)

time discipline better than ±10 seconds

5 V DC / 12 V DC / 24 V DC (up to 60 mA)selectable for each channel

from 1 to 4 x C-size 3.6 V high power battery

±10 V DC ; ±1.25 V DC (8x) (4 wires) (1)

±0.05 % FS

4-20 mA (2-3 wires)

0.05 % FS

±0.02 % FS

±0.1 % FS (full bridge)

0.2ºC

±0.8ºC

(2) Estimations with 4 batteries, considering laboratory conditions

(1) In case of reading of a Wheatstone bridge gauge, we suggest to have maximum 30m of signal cable from gauge to node

TECHNICAL SPECIFICATIONS PHYSICAL FEATURES

Box Dimensions (WxLxH)

Overall Dimensionswithout antenna (WxLxH)

External Antenna

Housing material

IP class

Operating temperature

100x200x61 mm

140x220x61 mm

114 mm length (including connector)

Aluminium alloy

IP67

-40°C to +80°C

BATTERY LIFE ESTIMATION(2)

Page 6: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 6www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOGMINI NODE 0LSWR1CHANP0The Mini node is the easiest way to connect an electric load cell toWR LOG wireless network. Mini node can also manage potentiometers and ratiometric sensors. On a dedicated channel can be also connected a thermistor probe.The Mini node can also be used as a standalone single-channel logger for automatic monitoring and can be easily configured and connected with a USB cable and an Android phone.

Number of channels

Sampling rate

Internal data storage

Instruments power supply

Power supply

INSTRUMENT INPUTS

Potentiometer/Ratiometric measuring ranges

Potentiometer/Ratiometic accuracy (-40 to +80ºC)

Full Wheatstone bridge measuring ranges

Full Wheatstone bridge accuracy (-40 to +80ºC)

Single-ended voltage ranges

Single-ended voltage accuracy (-40 to +80ºC)

Thermistor measuring ranges

Thermistor accuracy (0 to +50ºC)

Pulse (dry contact) ranges

Pulse (dry contact) rate

Pulse (dry contact) accuracy

1 individually (configurable, no thermistor)1 thermistor (not configurable)

30 seconds to 1 day

Up to 200000 readings incl. time

5 V DC

1 or 2 x C-size 3.6 V high power battery

0÷5 V DC , 0÷1 V/V

±0.1% FS

±7.8 mV/V (4-wires) (1)

±0.13 %FS

0÷5 V DC

±0.5% FS (0.25 to 4.75 V DC)

0 to 2 MOhm

0.04 ºC (thermistor sensor error not included)

Pulse (dry contact) ranges

0 to 50 Hz

±1 pulse

TECHNICAL SPECIFICATIONS PHYSICAL FEATURES

Box Dimensions (WxLxH)

Overall Dimensions (WxLxH)

Housing material

IP class

Operating temperature

113x80x60 mm

120x80x66 mm

Polycarbonate

IP67

-40°C to +80°C

(1) In case of reading of a Wheatstone bridge gauge, we suggest to have maximum 30m of signal cable from gauge to node

sampling 5 minutes

sampling 1 hour

sampling 6 hours

Potentiometer + Thermistor

2 years

11 years

16 years

Gauge + Thermistor

1 year

8 years

15 years

Pulses

2 years

12 years

16 years

(2) Estimations with 2 batteries, considering laboratory conditions

BATTERY LIFE ESTIMATION(2)

Page 7: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 7www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOGDIGITAL NODE PRODUCT CODE 0LSWRDIG000

Digital node can manage 1 chain of maximum 30 digital Sisgeo instruments such as in-place inclinometers or tilt meters.Batteries are not included with the node and shall be ordered separatelly.

Input

RS485 mode

Instruments power supply

Sampling rate

Time synchronization by radio

Power supply

One RS485 channel and two SDI-12 channels

Modbus RTU, full or half-duplex supported

12 VDC (up to 350 mA)

30 seconds to 1 day

time discipline better than ±10 seconds

4 x C-size 3.6 V high power battery

TECHNICAL SPECIFICATIONS PHYSICAL FEATURES

Box Dimensions (WxLxH)

Overall Dimensions without antenna

External Antenna

Housing material

Operating temperature

100x200x61 mm

140x220x61 mm

114 mm length (including connector)

Aluminium alloy

-40°C to +80°C

10 IPI (always on), sampling 5 minutes

30 IPI (always on), sampling 5 minutes

30 IPI (always on), sampling 30 minutes

30 IPI (always on), sampling 6 h

10 IPI (timed mode), sampling 5 minutes

30 IPI (timed mode), sampling 5 minutes

30 IPI (timed mode), sampling 30 minutes

30 IPI (timed mode), sampling 6 h

60 days

12 days

72 days (2.3 months)

864 days (28.4 months)

80 days

22 days

130 days (4.3 months)

1500 days (4.1 years)

(1) Considering laboratory conditions

BATTERY LIFE ESTIMATION(1)

Page 8: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 8www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOGWIRELESS TILTMETER0LSWR02INC15Node with embedded biaxial tilt meter and temperature sensor for buildings and other civil structures monitoring. The inclinometer works with the box installed horizontally.Batteries are not included with the node and shall be ordered separatelly.

TECHNICAL SPECIFICATIONS PHYSICAL FEATURES

Box Dimensions (WxLxH)

Overall Dimensionswithout antenna

External Antenna

Housing material

Operating temperature

IP class

100x100x61 mm

150x120x61 mm

100 mm length (including connector)

Aluminium alloy

-40°C to +80°C

IP67

Sampling rate

Time synchronization by radio

Power supply

INCLINOMETER SENSOR

Technology

Axes

Range

Accuracy (over full range)

Resolution

Repeatability

Built-in temperature sensor resolution

Built-in temperature sensor accuracy

30 seconds to 1 day

time discipline better than ±10 seconds

from 1 to 2x C-size 3.6 V high power battery

MEMS

Two (biaxial)

±15°

±0.17% FS

0.001°

0.005°

0.1 ºC

±0.5 ºC

sampling 5 min, 2 x batteries

sampling 1 hour, 2 x batteries

sampling 6 hours, 2 x batteries

1.2 years

5.8 years

8.3 years

(1) considering South Europe environmental condition

BATTERY LIFE ESTIMATION(1)

Page 9: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 9www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOGSOFTWARE SUITE

Network communications configuration and control

Wireless data unit and sensor attributes display

Wireless data unit configuration

Sensor data in near real time

Conversion of raw sensor data in engineering units

Manual and automatic data download in .csv

Data transmitted in a secure manner

Remote change of sensor’s sampling rate

Data accessible through Modbus TCP

Able to push data on user FTP

Simple and fast connection to wireless node by USB-OTG cable

Runs on Android devices, OTG compatible only

Easy sensor configuration: ID, sampling rate, frequency sweep, interface type, etc.

Checks radio signal coverage

Records coordinates (GPS)

Downloads data from wireless node and sends by e-mail or saves it onthe Android device

Takes current reading

Updates wireless node firmware

GATEWAY NETWORK AND ASSET MANAGEMENT SOFTWARE (ON BOARD WEB SERVER) WR LOG CONFIGURATION APP FOR NODES

Page 10: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 10www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOG

up to 15 km

up to 4 km

up to 2 km

INTERNETEXAMPLE OF CITY APPLICATION

LONG RANGE RADIOOpen field

City street

Manhole in a city street

Tunnel

15 Km (10 Km for MINI NODE)

4 Km (2 Km for MINI NODE)

2 Km (1 Km for MINI NODE)

4 Km (2 Km for MINI NODE)

INSTRUMENTS Piezometer

Digital MEMS in-place inclinometer Crackmeter

Borehole extensometer

Anchor load cell

RADIO TECHNICAL SPECIFICATIONSISM sub 1 GHz operating frequency bands adjustable to each territory requirements

No repeaters needed

High sensitivity: down to -137 dBm

Transmission: +14 dBm high efficiency / +20 dBm

Maximum link budget: 151 dB / 157 dB

Remote sampling rate change

Bidirectional communications capabilities

Gateway

Node

Page 11: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 11www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOG

up to 15 km

up to

2 k

m up to 4 km

EXAMPLE OF MINES APPLICATION

up to 4 km

EXAMPLE OF TUNNEL APPLICATION

INSTRUMENTS Piezometer

Digital MEMS in-place inclinometer Crackmeter

Borehole extensometer

Anchor load cell

Gateway

Node

Page 12: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 12www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOGEXAMPLEM OF DAM APPLICATION

up to 15 km with node installed on pole

up to 4 km with node installed at soil level

up to

4 km

INSTRUMENTS Piezometer

BH profile digital inclinometer

3D crackmeter

Borehole extensometer

Gateway

Node

Page 13: OMNIAlog data acquisition systems · WIRELESS MONITORING SYSTEM WR LOG wireless monitoring system is composed by a number of nodes to which instruments are connected, and a gateway

WR LOG WIRELESS MONITORING SYSTEM 13www.sisgeo.com

WR

_LO

G_E

N_0

5_08

/201

9

WR_LOG

All the information in this document is the property of Sisgeo S.r.l. and should not be used without permission from Sisgeo S.r.l. We reserve the right to change our products without prior notice. The datasheet is issued in English and other languages. In order to avoid discrepancies and disagreement on the interpretation of the meanings, Sisgeo Srl declares that English Language prevails.

SISGEO S.R.L.Via F. Serpero 4/F120060 Masate (MI) Italy Phone +39 02 95764130 Fax +39 02 [email protected]

TECHNICAL ASSISTANCESISGEO offers customers e-mail and phone assistance to ensure proper use of instruments and readout and to maximize performance of the system.

For more information, email us: [email protected]

ACCESSORIES AND SPARE PARTS

GATEWAY LIGHTENING PROTECTION FOR ANTENNA0LSACCPRANT

GATEWAY MAINS POWER SUPPLY0LSWRGW2215

WALL MOUNTING BRACKETS FOR NODES 0LSACCMWALL

HORIZONTAL MOUNTING PLATE FOR WIRELESS TILTMETERS 0LSACCINCHP0

VERTICAL MOUNTING PLATE FOR WIRELESS TILTMETERS 0LSACCINCVP0

GATEWAY LIGHTENING PROTECTION FOR ETHERNET0LSACCPRETH

POLE MOUNTING BRACKET FOR NODES0LSACCPOL50

POLE MOUNTING BRACKET FOR WIRELESS TILTMETERS0LSACCINCPL0

C-SIZE BATTERY FOR NODES0LSWR0BATTC

Plate for pole monting of digital, analog and vibrating wire nodes. It includes U-bolts and nuts for Ø 50 mm poles.

Plate for pole monting of wireless tiltmeters. It includes U-bolts and nuts for Ø 50 mm poles.

RF coaxial surge protection on radio link. P8AX09-6G-N/MF series from CITEL.

AC/DC, IP67 class.Vin 90-264 Vac, 47-63 Hz.Vout 13.2 Vdc, 1.2 A.Operating temp range -20 to +60°C

Suitable for all nodes model, except for Mininode.Composed by 2 mounting Brackets, aluminium made.

Plate for wireless tiltmeter to be installed on horizontal surface. Dimensions: 130x102x5 mm

L shaped plate for wireless tiltmeter to be installed on vertical walls. Overall dimensions: 120x102x50 mm, thikness 10 mm.

Indoor Ethernet surge protection. Transient protection circuit based on high energy gas discharge tubes and a network of fast response silicon avalanche diodes (SAD) to achieve sharp clamping of very large surge events.

3.6 V lithium-thionyl chloride high power C-size spiral cell for nodes power supply. Minimum pulse capability: 2000mA. Minimum continuous current: 1000mA.Minimum capacity: 6.0Ah.

WALL MOUNTING BRACKETS FOR MININODE 0LSPLAMWALL

Suitable for Mininode only.Composed by 2 mounting Brackets, plastic made.