office of nonproliferation research and development snm ... · ♦ low-noise hybrid preamplifier...

1
SNM Movement Detection / Radiation Sensors and Advanced Materials Portfolio Review Office of Nonproliferation Research and Development Development of Room-temperature CdMnTe Gamma-ray Detectors CdMnTe materials have wide bandgap, high resistivity, fair electron-transport properties, and good compositional uniform- ity. All these features make CdMnTe a good candidate for low- cost, high-resolution room-temperature gamma-ray detector. Using several techniques available at BNL, we are charac- terizing CdMnTe as a material for gamma-ray detectors. The consequent improvements in growth, fabrication, and manufac- turing techniques for CdMnTe potentially yield a suitable mate- rial for sensing devices with lower production costs. Success of this research has the possibility of generating high impact to nuclear nonproliferation with the goal of offering inexpensive highly sensitive gamma spectrometers. Project Overview Facilities and Techniques Crystal growing vendors: * Yinnel Tech, Inc., South Bend, IN; * Institute of Physics, PAS, Poland. We are also establishing in-house capability for CdZnTe crystal growth. (See poster on “Novel Method for Growing Te-inclusion-Free CZT”) CdMnTe Ingot Wafers Planar detector High spatial resolution X-ray mapping x y Synchrotron Radiation 10-μm tungsten collimator 10-μm x10-μm X-ray beam * Using a MCA we measure the energy spectrum for each point of the detector area. * Then we analyze the data and record the peak channel for each point of the detector area. * Next we plot the peak- channel vs. x-y position. X-ray map of a 3x3x7mm 3 CZT detector Counts Counts We can interrogate areas as small as 10x10 μm 2 Energy spectra Channel number Progress to Date Spectra_CMT_4513 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 Channel number Counts Bias 350V Bias 300V Bias 250V Am-241 peak Gain: 1k, Shapping time: 2 us Example of good samples - No.4513: Cd 0.94 Mn 0.06 Te:V Our first CdMnTe detector (Vanadium = 5x10 16 cm -3 ). 9x8.5x1.8 mm 3 with active area 28.3 mm 2 . Resistivity: 3.2x10 10 Ω⋅cm. Material response to incident gammas observed. μτ e 2.1x10 -4 cm 2 /V. Good starting point for crystal growth. IR (Infrared) imaging 3-D IR scanning * Field-of-View: 10.6x7.8 mm 2 * Image size: 3000x2208 pixels * Pixel size: 3.5 μm 1.56mm 2.12mm EPD (Etch Pits Density) measurements I-V measurements Spectroscopy system Revealing the microstructure and defects in the crystals; Etching solutions: * E-solution (HNO 3 :H 2 O:K 2 Cr 2 O 7 + AgNO 3 ) * Nakagawa (H 2 O:H 2 O 2 :HF) Sealed gamma-ray source Low-noise hybrid preamplifier NIM modules for signal processing Multiple Channel Analyzer in computer Polishing (Bromine in Methanol) Surface passivation Electroless ohmic contact White beam x-ray diffraction topography Sample X-ray Beam L Imaging Plate Beam stop Conclusions * CdMnTe is very promising as a material for gamma-ray detec- tion. * BNL has unique and comprehensive techniques for characteri- zation of CdMnTe material and fabrication and test of CdMnTe detectors. * BNL works closely with crystal growing vendors to improve CdMnTe growing process. * We fabricated the first CdMnTe detector. * Development of room-temperature CdMnTe gamma-ray de- tectors will benefit nuclear nonproliferation applications. Effects of annealing on material properties Annealing in a gradient temperature found to reduce the Te precipitates and inclusions. Annealing in constant temperature with Cd overpressure re- duce V Cd (acceptors) thus increasing the resistivity. Dislocation density and its effect on μτ product Dislocation density is low in the central areas of crystals, while high close to the surface (ampoule wall) Dislocations may affect charge collection. The sample after 4-day annealing in Cd vapour in a temperature gradient of 10 K/cm. EPD measurements IR imaging Etch pits Grain boundaries Grain boundaries 10x IR images of as-grown CMT crystal. Te inclusions can be seen with certain pat- terns. 10x image of etch pits of the same area of the crystal. Corre- lation can be found. (Etched by Nakagawa solution) Research Team: Y. Cui, G. Camarda, A. Hossain, G. Yang, and R. B. James, BNL Sub-contractors: L. Li, Yinnel Tech, Inc., South Bend, IN A. Mycielski, Institute of Physics PAS, Warsaw, Poland Other Universities: A. Burger, Fisk University, TN Budget: $480k (FY08), $485k (FY09), and $490k (FY10) A. E. Bolotnikov*, Y. Cui, G. Camarda, A. Hossain, G. Yang, and R. B. James Brookhaven National Laboratory Relevant to NA-22 Mission The yield of this project will be a technique to grow and fab- ricate novel CdMnTe radiation detectors with low-cost, high en- ergy-resolution, and ambient-temperature operation. Potentially, CdMnTe offers the same advantages of compactness and sim- plicity of operation as CdZnTe, and, in addition, it overcomes the limitation of crystal quality and low production yield. To- gether with highly integrated electronics circuit, CdMnTe detec- tors can be used in large area/volume radiation detection sys- tems as well as highly compact portable/hand-held radiation de- tection devices. Such systems/devices are widely used in non- proliferation applications, e.g. radiation-field surveys, treaty verification, and nonproliferation accounting. Acknowledgments This work is supported by U.S. Department of Energy, Office of Nonproliferation Research and Development, NA-22. Detector Fabrication Research Approaches We collaborate with CdMnTe growing vendors on: * Crystal growth; * Post-growth thermal processing. We establish in-house techniques to characterize CdMnTe materials and test detectors: * Detector fabrication (polishing, etching, coating, etc.); * Customized systems (IR, I-V, Spectroscopy, etc.); * Unique technique at NSLS. We feedback the test results to crystal growing vendors and work together to improve / modify the growing process.

Upload: trinhkhanh

Post on 05-Jun-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Office of Nonproliferation Research and Development SNM ... · ♦ Low-noise hybrid preamplifier ... * We fabricated the first CdMnTe detector. * Development of room-temperature

SNM Movement Detection / Radiation Sensors and Advanced Materials Portfolio Review Office of Nonproliferation Research and Development

Development of Room-temperature CdMnTe Gamma-ray Detectors

CdMnTe materials have wide bandgap, high resistivity, fair electron-transport properties, and good compositional uniform-ity. All these features make CdMnTe a good candidate for low-cost, high-resolution room-temperature gamma-ray detector.

Using several techniques available at BNL, we are charac-terizing CdMnTe as a material for gamma-ray detectors. The consequent improvements in growth, fabrication, and manufac-turing techniques for CdMnTe potentially yield a suitable mate-rial for sensing devices with lower production costs.

Success of this research has the possibility of generating high impact to nuclear nonproliferation with the goal of offering inexpensive highly sensitive gamma spectrometers.

Project Overview Facilities and Techniques

♦ Crystal growing vendors: * Yinnel Tech, Inc., South Bend, IN; * Institute of Physics, PAS, Poland.

♦ We are also establishing in-house capability for CdZnTe crystal growth. (See poster on “Novel Method for Growing Te-inclusion-Free CZT”)

CdMnTe Ingot Wafers Planar detector

High spatial resolution X-ray mapping

x

y

Synchrotron Radiation

10-μm tungsten collimator

10-μm x10-μm X-ray beam

* Using a MCA we measure the energy spectrum for each point of the detector area.

* Then we analyze the data and record the peak channel for each point of the detector area.

* Next we plot the peak-channel vs. x-y position.

X-ray map of a 3x3x7mm3 CZT detector

Cou

nts

Cou

nts

We can interrogate areas as small as 10x10 µm2

Energy spectra

Channel number

Progress to Date

Spectra_CMT_4513

0

200

400

600

800

1000

1200

0 200 400 600 800 1000

Channel number

Cou

nts Bias 350V

Bias 300V

Bias 250V

Am-241 peak Gain: 1k, Shapping time: 2 us

Example of good samples - No.4513: Cd0.94Mn0.06Te:V

♦ Our first CdMnTe detector (Vanadium = 5x1016 cm-3). ♦ 9x8.5x1.8 mm3 with active area 28.3 mm2. ♦ Resistivity: 3.2x1010 Ω⋅cm. ♦ Material response to incident gammas observed. ♦ μτe ≈ 2.1x10-4 cm2/V. ♦ Good starting point for crystal growth.

IR (Infrared) imaging

♦ 3-D IR scanning * Field-of-View: 10.6x7.8 mm2 * Image size: 3000x2208 pixels * Pixel size: 3.5 μm

1.56

mm

2.12mm

EPD (Etch Pits Density) measurements

I-V measurements

Spectroscopy system

♦ Revealing the microstructure and defects in the crystals; ♦ Etching solutions:

* E-solution (HNO3:H2O:K2Cr2O7 + AgNO3) * Nakagawa (H2O:H2O2:HF)

♦ Sealed gamma-ray source ♦ Low-noise hybrid preamplifier ♦ NIM modules for signal processing ♦ Multiple Channel Analyzer in computer

♦ Polishing (Bromine in Methanol) ♦ Surface passivation ♦ Electroless ohmic contact

White beam x-ray diffraction topography

Sample

X-ray Beam L

Imaging Plate Beam stop

Conclusions * CdMnTe is very promising as a material for gamma-ray detec-

tion. * BNL has unique and comprehensive techniques for characteri-

zation of CdMnTe material and fabrication and test of CdMnTe detectors.

* BNL works closely with crystal growing vendors to improve CdMnTe growing process.

* We fabricated the first CdMnTe detector. * Development of room-temperature CdMnTe gamma-ray de-

tectors will benefit nuclear nonproliferation applications.

Effects of annealing on material properties ♦ Annealing in a gradient temperature found to reduce the Te

precipitates and inclusions. ♦ Annealing in constant temperature with Cd overpressure re-

duce VCd (acceptors) thus increasing the resistivity.

Dislocation density and its effect on μτ product

♦ Dislocation density is low in the central areas of crystals, while high close to the surface (ampoule wall)

♦ Dislocations may affect charge collection.

The sample after 4-day annealing in Cd vapour in a temperature gradient of 10 K/cm.

EPD measurements

IR imaging

Etch pits

Grain boundaries Grain boundaries

10x IR images of as-grown CMT crystal. Te inclusions can be seen with certain pat-terns.

10x image of etch pits of the same area of the crystal. Corre-lation can be found. (Etched by Nakagawa solution)

Research Team: Y. Cui, G. Camarda, A. Hossain, G. Yang, and R. B. James, BNL Sub-contractors: L. Li, Yinnel Tech, Inc., South Bend, IN A. Mycielski, Institute of Physics PAS, Warsaw, Poland Other Universities: A. Burger, Fisk University, TN Budget: $480k (FY08), $485k (FY09), and $490k (FY10)

A. E. Bolotnikov*, Y. Cui, G. Camarda, A. Hossain, G. Yang, and R. B. James Brookhaven National Laboratory

Relevant to NA-22 Mission The yield of this project will be a technique to grow and fab-

ricate novel CdMnTe radiation detectors with low-cost, high en-ergy-resolution, and ambient-temperature operation. Potentially, CdMnTe offers the same advantages of compactness and sim-plicity of operation as CdZnTe, and, in addition, it overcomes the limitation of crystal quality and low production yield. To-gether with highly integrated electronics circuit, CdMnTe detec-tors can be used in large area/volume radiation detection sys-tems as well as highly compact portable/hand-held radiation de-tection devices. Such systems/devices are widely used in non-proliferation applications, e.g. radiation-field surveys, treaty verification, and nonproliferation accounting.

Acknowledgments This work is supported by U.S. Department of Energy, Office of Nonproliferation Research and Development, NA-22.

Detector Fabrication

Research Approaches ♦ We collaborate with CdMnTe growing vendors on:

* Crystal growth; * Post-growth thermal processing.

♦ We establish in-house techniques to characterize CdMnTe materials and test detectors: * Detector fabrication (polishing, etching, coating, etc.); * Customized systems (IR, I-V, Spectroscopy, etc.); * Unique technique at NSLS.

♦ We feedback the test results to crystal growing vendors and work together to improve / modify the growing process.