Dynamic Multivariate Accelerated Corrosion Test Protocol Problem Exposure Sites This work was conducted by the following: 1) University of Dayton Research Institute 2) Adirondack Analytics 3) Air Force Research Laboratory This work was supported by SERDP/ESTCP, Project # WP-1674. Presented at the 6 th ASETSDefense Workshop in Orlando, FL. Laboratory corrosion test protocols do not predict service life. Laboratory corrosion test results must be verified with outdoor corrosion testing. A new accelerated laboratory corrosion test protocol is needed. Ag AA7075-T6 AA2024-T3 AA6061-T6 Cu 1010 Carbon Steel Daytona Beach, FL Wright Patterson AFB, OH Kirtland AFB, NM Tyndall AFB, FL Pt. Judith, RI Hickam AFB, HI University National Oceanographic Laboratory System (UNOLS) Ships - University of Delaware - University of Washington Corrosion of field samples correlates more strongly to Temp and %RH than UV/O 3 . • For field exposure time is the dominant factor in corrosion severity. • Degradation of coatings in B117 with UV/O 3 more pronounced than B117 alone. • Full Cr coating system degradation in B117 more like field than B117 UV/O 3 . • Mg-rich coating system degradation in B117 UV/O 3 more like field than B117 alone. • High UV/O 3 levels in B117 more corrosive than field sites with high UV/O 3 . • Surface chemistry & morphology different for chamber & field at similar mass loss. Ship- mounted bare sample picture frame Land site- mounted bare sample exposure card Substrates / Coating Systems Deployed Land site-mounted coated and bare sample exposure rack Issues Multiple lab corrosion tests are used: ASTM B117 for aluminum alloys GM 9540P for steel Does not account for UV, O 3 , temp, %RH. Outdoor & laboratory corrosion testing vary: Rank order Failure mode Objectives Technical Approach Results Develop a test protocol to predict coating and alloy lifetime performance. Accelerated test chamber development, including UV and ozone. Service environments are variable in nature (e.g., beachfront vs. desert). The test protocol is dynamically “tunable” to match service environment. Panels of bare Al AA2024-T3, AA6061-T6, AA7075-T6, and 1010 steel, pure silver and pure copper were exposed to eight environments and two test chambers. Test chambers: 5% NaCl salt fog (ASTM B117). 5% NaCl salt fog, UV, O 3 . Mass loss determinations, corrosion morphology and elemental analysis were used to investigate correlations between outdoor and laboratory sites. Qualitative & quantitative (SEM-EDS, FTIR) rankings were made after 1 and 2 years. Weather data was recorded on deployed weather monitoring systems or from EPA. A proof of concept model for predicting atmospheric corrosion rates of 1010 steel was developed using a cumulative damage non- linear modeling and simulation approach. 12 months Daytona Beach 600 hrs High UV – High O 3 600 hrs Low UV – Low O 3 700 hrs Low UV – High O 3 800 hrs High UV – Low O 3 800 hr ASTM B117 Different morphology: While comparable mass loss to the field exposure is observed at an accelerated rate in the modified exposure chamber, the surface morphology of the corrosion products are different. This may be due to kinetics more so than surface chemistry. Daytona Beach:12m Mass Change: AA2024 Accelerated Combined-Effects Simulation (ACES) Chamber Smart Rack DISTRIBUTION A. Approved for public release: distribution unlimited; Case Number: 88ABW-2016-5941, 21 Nov 2016.

Upload: others

Post on 04-Aug-2021

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Objectives Dynamic Multivariate Accelerated Corrosion Test … · • ASTM B117 for aluminum alloys • GM 9540P for steel • Does not account for UV, O. 3, temp, %RH. • Outdoor

Dynamic Multivariate Accelerated Corrosion Test Protocol

Problem

Exposure Sites

This work was conducted by the following:

1) University of Dayton Research Institute

2) Adirondack Analytics

3) Air Force Research Laboratory

This work was supported by SERDP/ESTCP, Project # WP-1674.

Presented at the 6th ASETSDefense Workshop in Orlando, FL.

• Laboratory corrosion test protocols do not predict service life.

• Laboratory corrosion test results must be verified with outdoor corrosion testing.

• A new accelerated laboratory corrosion test protocol is needed.

• Ag• AA7075-T6• AA2024-T3• AA6061-T6• Cu• 1010 Carbon Steel

• Daytona Beach, FL• Wright Patterson AFB, OH• Kirtland AFB, NM• Tyndall AFB, FL• Pt. Judith, RI• Hickam AFB, HI

• University National OceanographicLaboratory System (UNOLS) Ships

- University of Delaware- University of Washington

• Corrosion of field samples correlates more strongly to Temp and %RH than UV/O3.• For field exposure time is the dominant factor in corrosion severity.• Degradation of coatings in B117 with UV/O3 more pronounced than B117 alone.• Full Cr coating system degradation in B117 more like field than B117 UV/O3.• Mg-rich coating system degradation in B117 UV/O3 more like field than B117 alone.• High UV/O3 levels in B117 more corrosive than field sites with high UV/O3.• Surface chemistry & morphology different for chamber & field at similar mass loss.

• Ship-mounted bare sample picture frame

• Land site-mounted bare sample exposure card

Substrates / Coating Systems Deployed

• Land site-mounted coated and bare sample exposure rack

Issues• Multiple lab corrosion tests are used:

• ASTM B117 for aluminum alloys• GM 9540P for steel

• Does not account for UV, O3, temp, %RH.• Outdoor & laboratory corrosion testing vary:

• Rank order• Failure mode

Objectives

Technical Approach

Results

• Develop a test protocol to predict coating and alloy lifetime performance.

• Accelerated test chamber development, including UV and ozone.

• Service environments are variable in nature (e.g., beachfront vs. desert).

• The test protocol is dynamically “tunable” to match service environment.

• Panels of bare Al AA2024-T3, AA6061-T6, AA7075-T6, and 1010 steel, pure silver and pure copper were exposed to eight environments and two test chambers.

• Test chambers:• 5% NaCl salt fog (ASTM B117).• 5% NaCl salt fog, UV, O3.

• Mass loss determinations, corrosion morphology and elemental analysis were used to investigate correlations between outdoor and laboratory sites.

• Qualitative & quantitative (SEM-EDS, FTIR) rankings were made after 1 and 2 years.

• Weather data was recorded on deployed weather monitoring systems or from EPA.

• A proof of concept model for predicting atmospheric corrosion rates of 1010 steel was developed using a cumulative damage non-linear modeling and simulation approach.

12 monthsDaytona Beach

600 hrsHigh UV – High O3

600 hrsLow UV – Low O3

700 hrsLow UV – High O3

800 hrsHigh UV – Low O3

800 hrASTM B117

Different morphology: While comparable mass loss to the field exposure is observed at an accelerated rate in the modified exposure chamber, the surface morphology of the corrosion products are different. This may be due to kinetics more so than surface chemistry.

Daytona Beach:12m

Mass Change: AA2024

Accelerated Combined-EffectsSimulation (ACES) ChamberSmart Rack