NVR500 Series Network Video Recorders
Quick Guide
Manual Version: P100‐20140128
© 2014, Zhejiang Uniview Technologies Co., Ltd. and its licensors
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Zhejiang Uniview Technologies Co., Ltd.
Notice
The information in this manual is subject to change without notice. Every effort has been made in the preparation of this manual to ensure accuracy of the contents, but all statements, information, and recommendations in this manual do not constitute the warranty of any kind, express or implied.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and disposal of this product, national laws and regulations must be observed.
Preface
Audience
This manual is intended for: Surveillance system planners Field technical support and servicing engineers Software installation, configuration, and servicing administrators Product users
Precautions
If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, you might be required to take corrective actions.
Do not remove the dismantlement‐preventive seal from the chassis cover of the device without permission. If you want to open the
chassis, contact the local agent of our company for help. Otherwise, we shall not be held liable for any consequence caused thereby.
Make sure the device is sturdy and well grounded and meets heat dissipation and lightning protection requirements. Avoid vibration when using the device.
Provide a stable and compliant power supply before powering on the device.
Before performing the verification (refer to section “Check Before Power‐On”), make sure that the power is disconnected, for fear of bodily injury or equipment damage caused by incorrect cable connection.
Power interruption may cause hard disk damage or abnormal functions. To shut down the device, strictly follow the instructions. If power interruption often occurs, configure an uninterrupted power supply (UPS).
Safety and Compliance Information
Conventions Used Symbol
The symbols in this chapter are shown in the following table. They are used to remind the reader of the safety precautions during equipment installation and maintenance.
Safety Symbol
Description
Generic alarm symbol: To suggest a general safety concern.
ESD protection symbol: To suggest electrostatic‐sensitive equipment.
Electric shock symbol: To suggest a danger of high voltage.
Safety Information
WARNING!
Installation and removal of the unit and its accessories must be carriedout by qualified personnel. You must read all of the Safety Instructionssupplied with your equipment before installation and operation.
Warnings:
If the product does not work properly, please contact your dealer or the nearest service center. (We shall not assume any responsibility for problems caused by unauthorized repair or maintenance.)
To reduce the risk of fire or electrical shock, do not expose this product to rain or moisture.
This installation should be made by a qualified service person and should conform to all the local codes.
Please install blackouts equipment into the power supply circuit for convenient supply interruption.
The separate earthing terminal must be permanently connected to earth.
For AC supplied model: The plug‐socket combination must be accessible at all times as it serves as the main disconnecting device.
Before the power cable is installed or removed, the power must be turned off.
To avoid heat accumulation, good ventilation is required for a proper operating environment.
Improper use or replacement of the battery may result in hazard of explosion. Please use the manufacturer recommended battery type.
Caution: Fiber optic ports – optical safety.
Never look at the transmit laser while the power is on. Never lookdirectly at the fiber ports and the fiber cable ends when they arepowered on.
Caution: Use of controls or adjustments to the performance orprocedures other than those specified herein may result in hazardouslaser emissions.
Regulatory Compliance
FCC Part 15
This equipment has been tested and found to comply with the limits for digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This product complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including
interference that may cause undesired operation.
LVD/EMC Directive
This product complies with the European Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC.
WEEE Directive–2002/96/EC
The product this manual refers to is covered by the Waste Electrical & Electronic Equipment (WEEE) Directive and must be disposed of in a responsible manner.
i
Contents
1 Overview ............................................................................................... 1
2 Appearance ........................................................................................... 1
Front View ..................................................................................................... 1
Indicators ...................................................................................................... 1
Rear View ...................................................................................................... 3
Interfaces ...................................................................................................... 4
3 Mounting .............................................................................................. 5
Installation Check .......................................................................................... 5
Installing Hard Disks ...................................................................................... 6
Installing the Equipment ............................................................................... 8
Mounting to the Workbench ................................................................ 8
Mounting into a Cabinet ....................................................................... 8
Installing a Power Module (Optional) ........................................................... 9
Installing the Decode Card (Optional) ......................................................... 10
4 Connecting Cables ............................................................................... 11
Connecting to Alarm Input/Output Device ................................................. 11
Connecting to a Third‐Party Device ............................................................ 12
RS485 Serial Cables ............................................................................. 12
Connecting to a third‐party device via RS485 interface ..................... 13
Connecting RS232 Serial and Network Cables ............................................ 15
Connecting a Groundcable .......................................................................... 16
5 Switching On/Off the Device ................................................................ 16
Check Before Power‐On .............................................................................. 16
Turning on the Device ................................................................................. 17
Soft Shutdown ............................................................................................. 17
Soft Shutdown Using the ON/OFF Button .......................................... 17
Soft Shutdown through Man‐Machine Interface ............................... 17
ii
Soft Shutdown through Web Interface .............................................. 17
6 Common Configurations ...................................................................... 18
Man‐Machine Interface .............................................................................. 18
About the Interface ............................................................................ 18
Menu Structure .................................................................................. 19
Initial Configuration .................................................................................... 19
Quickly Adding IPC ...................................................................................... 25
Preview ....................................................................................................... 28
Pane Toolbar on the Preview Interface .............................................. 28
Preview Status .................................................................................... 29
Right‐click Context Menu ................................................................... 30
Recording .................................................................................................... 32
Playback ...................................................................................................... 32
Backup ......................................................................................................... 32
Prerequisites ....................................................................................... 33
Procedure ........................................................................................... 33
Web Interface ............................................................................................. 36
7 Specifications ...................................................................................... 37
8 HDD Storage Calculation Chart ............................................................. 37
1
1 Overview
As new‐generation network video recorder for professional clients and
commercial customers, NVR500 series incorporates a wide range of
features including video management, data management, iSCSI storage,
media switch. Delivering characteristics of high performance, stability
and capacity, NVR500 uses the redundancy design in key components
and provides a rich set of extensible interfaces for different applications
including intelligent buildings, schools, hospitals, financial institutions,
power substations.
Operating under embedded operation system, NVR500 features
compact structure and powerful video/audio decoding ability.
2 Appearance The photos herein are for illustration only and may vary according to
actual conditions.
Front View
Indicators
As shown in the front view, the following table describes the indicators
on the front panel. The LED color may vary with the equipment model
(blue or green).
2
Table 2‐1 Status Indicators
Indicators Color Status Description
NET
(network indicator) Green
Constantly on Network properly connected
Off No network connection
PWR
(power indicator) Green
Constantly on Power connected
Off No power
IR
(remote control indicator)
Green
Constantly on Device is selected and can be remotely controlled
Blinking Device is being verified
Off Device is not selected and cannot be remotely controlled
RUN
(running indicator) Green
Constantly on Running normally
Blinking Starting
Off Shut down
SLOT
(Card indicator) Green
Constantly on Card in slot
Blinking No card in slot
LINK (External device indicator)
Green Constantly on Device connected
Blinking Device unconnected
HD
(hard disk indicator)
Green
Constantly on Running properly without data access
Blinking Running properly with data access
Red
Constantly on The hard disk is faulty
Blinking The disk array is being rebuilt
3
Indicators Color Status Description
‐
Off Hard disk is not installed or the system shuts down, or the indicator turns red
ALM
(alarm indicator) Red
Constantly on Equipment alarms
Off The system runs normally without alarms
Rear View
NVR516‐128‐IN
NVR516‐64‐IN
4
Interfaces
As shown in the rear view, the following table describes interfaces on
the rear panel.
Table 2‐2 Interfaces
No Item Description Function and Instructions
RS‐485/422 Interface
Compatible with RS485 and RS422 serial ports and RJ45 connectors
Connecting to RS485 or RS422 devices
AC 100V ‐ 240V
AC power, 100V‐240V AC
Connecting to the power supply
POWER Power switch
Turn on/off device when connected to power
Note:
To protect hard disks, please soft‐shut down your equipment before turning off the power.
RS‐485 Interface
RS485 serial port, Phoenix connector
Connecting to RS485 devices
ALARM IN Boolean input, Phoenix connector
Connecting to alarm input device
ALARM OUT Relay output, Phoenix connector
Connecting to alarm output device
GROUND Equipment grounding Ground cable
AUDIO OUT Analog audio output, BNC interface, Mono, 1.4V (P‐P), and 300 Ω
Connecting to an audio output device
AUDIO IN Analog audioinput, NC, single channel,2V (P‐P),10KΩ
Connecting to an audio input device
GROUND Equipment grounding
Ground cable
HDMI High‐definition digital audio and video output, HDMI interface
Connecting to HDMI display device
1
2
3
4
5
6
7
5
No Item Description Function and Instructions
RST Button Reset button
Holding the button for five seconds restores the factory default settings
Power Button
Soft shutdown button
Allow you to stop the running system processes when the device is powered on
miniSAS interface
2 mini SAS (only available in NVR516‐128‐IN)
Network storage expansion unit
eSATA (Optional)
Interface with external storage device
Connecting to eSATA hard disk
USB InterfaceUSB2.0 interface, limited to 1A
Connecting to an external USB mouse or storage device
RS‐232 Interface
Compatible with RS232 serial ports and RJ45 connectors
Connecting to devices for commissioning and maintenance
LAN interface
10/10/1000BASE‐T self‐adaptive Ethernet electrical port, RJ45 connector
Connecting to Ethernet
3 Mounting
Installation Check
Open the packing box and check the equipment model, accessory types
and quantities to ensure all the components are available.For
equipment model and accessory types and quantities, please refer to
the packing list.
8
9
10
11
12
13
14
6
Installing Hard Disks
For supported hard disk types, consult our authorized sales or technical
support staff.The following examples illustrate how to install hard disks
on a workbench. The installation process may vary according to
conditions.
The hard drive interface is located inside the device. You need to remove
the front panel to install the hard disk.The hard disks are hot‐swappable
and support mixed insertion. The disks can be powered on in order to
minimize the impulse current produced during the power‐on process.
WARNING!
The hard disk can be hot‐plugged only when no data is reador written. The hard disk indicator is not blinking when no data is processed.
Please wear anti‐static gloves before installing a hard disk. Insert hard disks into the slots of a running device at an interval of
at least six seconds
Install a hard disk into the NVR500 Series as follows:
1. Fix the hard disk to with screws to the handle bar on the correct
side.
2. Loosen the screws that secure the chassis cover with a cross
screwdriver.
7
3. Align the hard disk with the slot and push in the hard disk gently
and steadily.
4. Push the hard disk in position with your thumb until the buckles
click.Repeat the above steps to install all the hard disks.
5. Cover the front panel and fix the screws to secure the front panel.
8
Installing the Equipment
The equipment provides front, side and back ventilation channels. Leave
room of at least 30cm to the front and back and 10cm to the left and
right sides of the equipment for ventilation.
Mounting to the Workbench
1. Get the stickers from the foot pads delivered with the equipment,
and attach the pads to the bottom of the equipment where
appropriate.
2. Place the equipment on a clean workbench. Now the installation
process is complete.
Mounting into a Cabinet
WARNING!
Ensure that the cabinet is equipped with a tray or slide rail beforeinstalling the equipment in a cabinet. The equipment must be supportedon a tray or slide rail instead of a suspension loop.
1. As shown in the following figure, place the suspension loop with a
screw hole close to the chassis. Align the suspension loop with the
screw hole, and use two M4*8 screws to fasten the suspension
loop to the chassis.
9
2. Perform the same procedure to mount the suspension loop on the
other side of the chassis.
1: Screws (4)
2: Slotted hole
3: Suspension loop
3. Place the equipment on the cabinet support, and slid it into the
cabinet. Fix the suspension loop to the floating nut to the front
mounting bar of the cabinet with screws led through the slotted
hole.
Installing a Power Module (Optional)
WARNING!
Before you install a power module, ensure that you hace powereddown the device to avoid personal injury or device damage.
Please wear anti‐static gloves when installing the power module.
The device supports power modules with power supply range of
100V~240V AC.
Install a power module as follows:
1: Loosen one screw to remove the cover.
2: Insert the power module
3: Thread and tighten the screws
10
Installing the Decode Card (Optional)
WARNING!
Before you install the decode card, ensure that you hace powereddown the device to avoid personal injury or device damage.
Please wear anti‐static gloves when installing the decode card.
The device supports 4/6‐channel HDMI audio & video decoder. You can
choose the desired decoder as required.
Install a power module as follows:
1: Loosen one screw to remove the cover.
2: Insert the decode card
3: Thread and tighten the screws.
11
4 Connecting Cables Connecting to Alarm Input/Output Device
Twisted pair is recommended. 22‐28AWG insulating core wire,
preferably 24AWG or 26AWG can be used.
1: Any terminal on the ALARM IN interface
2: Alarm input circuit inside the device
3: Ground
4: Terminal G on ALARM IN interface
5: Normal open/closed Boolean alarm input device
1: Alarm output circuit inside the device
2: Any positive terminal on ALARM OUT interface
3: Boolean alarm output device
4: DC power
5: Any negative terminal on ALARM OUT interface, corresponding to 2
12
1: Alarm output circuit inside the device
2: Any positive terminal on ALARM OUT interface
3: Boolean alarm output device
4: AC power
5: Any negative terminal on ALARM OUT interface, corresponding to 2
Connecting to a Third‐Party Device
The device supports two types of RS485 interface: RJ45 and Phoenix
connector for connection with third‐party devices.
RS485 Serial Cables
Twisted pair is recommended. 22‐28AWG insulating core wire,
preferably 24AWG or 26AWG can be used.
Refer to the table below for the maximum length of RS485 serial
cables with different baud rates.
Table 4‐1 Maximum length of RS485 serial cables with different baud
rates
Baud rate (bps) Maximum length (m)
1200, 2400, 4800, 9600, 19200 900
38400 850
57600 550
115200 250
13
Connecting to a third‐party device via RS485 interface
Use an RS485 (422 compatible) connector under the RJ45 category
to connect to a third‐party device.
A third‐party device control cable must be an RS485 cable that meets
the following requirements:
• The RJ45 connector's T+ and R+ terminals are shorted and then
connected to the third‐party device's RS485+ connector; the RJ45
connector's T‐ and R‐ terminals are shorted and then connected to
the RS485 connector of the third‐party device, as shown in the
following figure.
• If the third‐party device is grounded, the third‐party device control
cable's Terminal G is connected to the RJ45 connector's Terminal G
(No.7 or 8).
1: Third‐party device RS485 control cable
2: RS485+
3: RJ45 connector's T+ and R+ terminals are shorted
4: RS485‐
5: RJ45 connector's T‐ and R‐ terminals are shorted
6: Twisted pair
When using an RS422 cable as a third‐party device control cable,
connect the cable as follows:
• Connect RJ45's T+ to the third‐party device's R+; RJ45's T‐ to the
third‐party device's R‐; RJ45's R+ to the third‐party device's T+;
RJ45's R‐ to the third‐party device's T‐, as shown in the following
figure.
14
• If the third‐party device is grounded, the third‐party device control
cable's Terminal G is connected to the RJ45 connector's Terminal G
(No.7 or 8).
1: Third‐party device RS422 control cable
2: Twisted pair
Connect a third‐party device using a Phoenix connector's RS485
terminal.
Do as follows:
• Connect the Phoenix connector's Terminal A to the RS485 terminal
of the third‐party device; Terminal B to the RS485‐ terminal of the
third party device as shown below.
• If the third‐party device is grounded, the third‐party device control
cable's Terminal G is connected to Terminal G of the Phoenix
connector.
1: RS485+
2: RS485‐
3: Third‐party device control cable
15
CAUTION!
Connect to a special‐purpose keyboard using the phoenix connector'sRS485的 3A、3B interface terminal similarly to connecting a third‐partydevice.
Connecting RS232 Serial and Network Cables
Through an RS232 serial port, connect the equipment to a serial device
such as a PC. For maintenance, use the following serial cables (take
PCX‐based DB9 as an example).
1: DB9 interface
2: RJ45 interface
As shown in the following figure (NVR516‐128‐IN as an example), please
connect the RS232 serial and network cables as required. The following
figure provides an example of connection through an electrical
interface.Connect the other end of a network cable according to the
actual conditions. The connection is not discussed here.
16
1: PC
2: Network cable
3: Serial cable
Connecting a Groundcable
To ensure personal and equipment safety(lightning protection and
resistance against interference), ground the device properly.
The ground cable must not exceed 30m and provide a grounding
resistance of less than 5 Ω. For specific requirements, refer to the
standards for the IEC61024 series.
As shown in the following figure (NVR516‐128‐IN as an example),
connect one end of the ground cable to the ground terminal of the
device and the other end to a reliable grounding point.
1: Ground terminal
2: Ground cable
5 Switching On/Off the Device Check Before Power‐On
To avoid bodily injury or damage to components, check the following
items before turning off the power.
1
2
17
• The device is firmly and securely installed without any screw left
unscrewed.
• Do not place anything on the device.
• All the installed cables are connected correctly.
• Use a power supply approved for the device.
Turning on the Device
Connect the power supply and power on the device. If the power LED
indicator on the backplane of the device is lit, it indicates that the device
is powered on successfully.
Soft Shutdown
Soft shutdown means a device is turned off to terminate the running
system processes, so that the device enters power saving mode.It is
recommended that you disconnect the device from the power
supply when the device is left idle for a long time.
Soft Shutdown Using the ON/OFF Button
Press the Soft Shutdown button on the backplane of the device, or
press the ON/OFF key on the remote control, to perform soft shutdown
after confirmation by logging in to the man‐machine interface.
Soft Shutdown through Man‐Machine Interface
Choose Menu > Maintenance > Shutdown. Click Shutdown to perform
soft shutdown after confirmation.
Soft Shutdown through Web Interface
Choose Maintenance > Device Maintenance > Shutdown. Click
Shutdown to perform soft shutdown after confirmation.
18
WARNING!
In the course of normal operation of the equipment or device is closed,do not disconnect the power while the equipment is running properly or shutting down, so as to not to damage the equipment
6 Common Configurations
The NVR500 Series can be operated through man‐machine and Web
interfaces.
Man‐Machine Interface
About the Interface
After the device starts, enter the man‐machine interface when the
display shows a progress bar.You can use the mouse or the front panel
for configuration and service monitoring on the man‐machine interface.
19
Menu Structure
Initial Configuration
You can simply configure the device to work properly as instructed by
the startup wizard.If you do not want the startup wizard to guide you
through fast configuration, just skip the wizard and log in as admin.
Follow steps 3 to 5 for fast configuration.
1. Determine whether to start wizard when device starts and click
Next.
Basic
Preview
Array
StorageMontion Detection
Server
NTP
information
Tamper‐proof
Video Loss
Alarms
Log
System Info
Backup
Upgrade
Restor
Serial
User
Boolean
Device Alarm
Shutdown
Menu
Backup Configuration Camera Storage Alarm Network Maintenance HelpRecord
Playback Toolbar
PTZ Toolbar
About the device
IR Remote Control
PPPoE
UNP
Basic
SMTP
20
2. Enter the admin user's password (admin by default). Click Next and
the interface of Configuration Wizardinterface appears.
3. Configure the network parameters.
a. Click Network Configuration to enter the Network
Configuration interface.
21
b. On the Basic tab, configure the IP address, subnet mask, and
default gateway.Normally, set other network parameters to
defaults.
c. After configuration, click OK. Configuring eth0 card causes the
system to restart service and then return to the Configuration
Wizard interface.
22
4. Configure system parameters.
a. Click System Configuration. The System Configuration
interface appears.
b. In the Server Configtab, select the management mode based
on the actual networking conditions.Normally, set other system
parameters to defaults.
c. After configuration, click OK.Changing the management
mode will restart the device.
5. Configure storage parameters.
a. Click Storage Configuration. The Storage Configuration
interface appears.
b. Building an array
i. In the Build Array box under the Array tab, enter the array
name, select the array type, and idle slots;
ii. Click Create. The newly created array is shown on the array
list.
23
c. Virtualizing anarray
Be sure to virtualize an array before using it. To do so, select the array in
the Virtualization Array box and click Virtualization.
NOTE!
Virtualization takes time. After virtualization is complete, "virtualized" inthe array list is displayed as "Yes".
24
d. Configuring storage resources
On the Storagetab, configure storage resource parameters. The
following table lists the important parameters.
e. Configuringstorage plans
25
i. On the Storage tab, click Storage Plan to configure a
general or exceptional storage plan.
ii. After configuration, click OK. The system returns to the
Storage Configuration tab.
iii. Click OK. The system returns to Configuration Wizard
interface.
NOTE!
On the day of exception plan, only storage plans outside of theexception period are implemented. Conventional plans areimplemented in other days.
The periods under a storage plan cannot overlap each other.
6. After all configurations, click Finish to save the settings and then
you can perform various operations.
Quickly Adding IPC
Only an admin user can add IPC. Before adding the IPC, confirm that:
• The IPC is functional, and the network is connected;
• The IPC resolution must not exceed 1920 in width and 1088 in
height.
The procedure is as follows:
1. Enter the video channel configuration interface.
To do so, choose Menu>Channel Management>Video Channel.
2. Quickly search for the IPC.
Click Search to enter the IPC Search interface. By default, a quick search
is performed when the interface is displayed.
26
3. Add our company's IPC.
• Add single IPC: Select one of our IPCs you want to add. The IPC
parameters are displayed below the list.(You can modify related
parameters, Important parameters are described in the following
table.) Click Add to add the IPC.
• Add IPCs in batches: Select a number of our IPCs you want to add.
Click Batch Add and the system will add IPCs in batches according to
default parameters.
27
4. Adding third‐party IPCs
• Add single third‐party IPC: Select a third‐party IPC you want to add.
The IPC parameters are displayed below the list. (You can modify
related parameters, important parameters are described in the
following table.) Click Add to add the IPC.
• Add IPCs in batches: Select a number of third‐party IPCs you want to
add. Click Batch Add and the system will add IPCs in batches
according to default parameters.
28
Preview
Pane Toolbar on the Preview Interface
In preview mode, click a pane. A toolbar related to the pane appears
below the pane.
Table 6‐1 Button Description in Pane Toolbar
Icon Name Description
Stop live Stops playing the live video in the current pane
PTZ controlClick this button to enter the PTZ control interface in preview mode.
Manual record
Records the live video in the current pane to a local destination. Click the button again to stop manual recording.
Instant playback
Plays back the videos recorded within 5 minutes before the current time point.
E‐magnify Zoom in on the live or recorded video in the current pane on a certain scale.
Capture image
Saves images in the current pane to a designated folder.
29
Icon Name Description
Note:
Images captured are stored by date in the root directory of your USB drive (a folder is automatically created and named "snap_ date").For example, images captured on March 24, 2013 are stored in a folder named "snap_2013‐03‐24".
Before capturing images, ensure that you have inserted a USB drive into the device.
Images captured in preview mode are named as follows: user name (camera name) current time.jpg.
Exit the tool bar
Exit the toolbar for the current pane.
Preview Status
On the preview screen, video and alarm status of each channel can be
identified by the identifier on the corresponding preview screen.
Table 6‐2 Preview Icons
Icon Name Description
Video playbackThis icon is shown in video playback mode (the playback toolbar).
Motion detection alarm
This icon is shown when a motion detection alarm occurs.
Temperature alarm
This icon is shown when a low or high temperature alarm occurs.
Tamper alarm This icon is shown when the front panel is removed.
30
Icon Name Description
Fan alarm This icon is shown when a fan alarm occurs.
Boolean input alarm
This icon is shown when a Boolean input channel alarm occurs.
Alarm triggering
This icon is shown when alarm triggering preview screen occurs.
Shield alarm This icon is shown when a shield alarm occurs.
Mute This icon is shown in mute mode.
Manual record This icon is shown in manual record mode.
Right‐click Context Menu
In the preview screen, the right‐click context menu is shown in the
following figure. Menu functions are described in the following table.
31
Table 6‐3 Preview Operations
Menu Item Description
Camera
When the selected pane switches to a digital channel screen, you can start or stop previewing digital channels such as IPC.
Note: When the camera connected on the channel gets offline, the corresponding digital channel will become unavailable. You can perform preview only when the camera comes online.
Prev Screen/ Next Screen
Displays the images available for preview on the previous or next screen based on current split screen mode and screen number during polling switching.
Multi‐Screen
Switches the split‐screen mode.
Note: Screens 3, 5 and 7 show videos in the corridor.
In split‐screen mode, services in panes other than the current screen will be disabled automatically.
Switch Monitor
Switches between screens on a man‐machine interface
Start Auto‐Switch
In the preview screen, poll‐switch between videos on various channels.
Video playback
Enters the channel video playback interface.
Note:
You can display this interface only when you preview images after logging into the device.
Main Menu
Used to access the main menu
Note:
You must log into the device.
Logout
Logs out and returns to the preview mode before login.
Note: You can display this interface only when you preview images after logging into the device.
32
Recording
This article describes how to manually record audio and video data on
different channels and store the data to a hard disk.
1. On the preview screen, select a pane for video recording. Click
Manual Record to start recording.
2. An icon will appear above the pane.
3. To stop manual recording, click Stop Recording on the toolbar.
Playback
The device can play back the videos recorded within 5 minutes before
the current time point to facilitate instant playback in case of exceptions.
Before instant playback, ensure that videos are recorded within 5
minutes before the current time point.
Do as follows:
On the preview screen, select the pane for video recording. Click the
Instant Playback icon to start playing.
Backup
On the man‐machine interface, search a hard disk for video records and
save the video records in the USB storage device as files.
33
Prerequisites
• The USB storage device is FAT32‐partitioned and formatted, and
properly connected to the device.
• You are permitted to play back videos.
• Ensure that video records are stored on the device's hard disks.
Procedure
1. Access the interface for record backup interface.
To do so, choose Menu>Recording Backup.
2. Query videos.
After selecting one or more channels on which you want to query video
records. Enter the start/end time. Click Query to display search results.
3. Select video records you want to back up.
Select one or more video records you want to back up. Click Backup to
enter the backup interface.
34
CAUTION!
After selecting the channel and entering the start/end time, click QuickBackup. On the interface for record backup, all the video records withinthe specified time periods on the selected channel will be backed up bydefault.
4. Select the backup path.
Select a partition of a USB storage device from the USB drive drop‐down
list.Select a folder, or double‐click to enter the directory and then select
a folder.
5. Backing up a video
Click Backup to start video backup.
35
CAUTION!
During the backup process, the progress bar will show "backing up X/Y:"x indicates the video records currently being backed up; y represents thetotal number of video records you want to back up.During the backupprocess, click Cancel on the progress bar to stop video backup.
36
NOTE!
If the duration of a video record for backup is less than half an hour,the record will be saved as a separate file; if the record exceeds halfan hour, the record will be automatically split into half‐hour unitsand saved as separate video files.
A backup video file is named as follows: camera name‐video starttime‐end time‐random value.file format.For example: camera01‐20121222000000‐20121223103000‐719885386.ts.
Click Refresh to show the free and full capacities of the currentpartition on the USB storage device.
Web Interface
1. Start a Web browser on the client computer. Enter the IP address
of the device in the address box (192.168.0.30 for network port 1
of NVR500; 192.168.1.30 for network port 2 ; 192.168.2.30 for
network port 3; and 192.168.3.30 for network port 4 by default).
2. Press Enter. For first login, load all latest controls as prompted by
the system.You should preferably install controls in the default
directory.
3. Enter the user name and password in the login dialog box (admin
by default), and click Log In to access the web interface.
CAUTION!
If you change to another OS user on the client and log in to the web pageagain after controls are successfully installed, you need to load thecontrols manually. Otherwise, you cannot log in.To load controlsmanually, enter /ActiveX/Setup.exe in the address bar after the device'sIP address, and press ENTER.
37
After successfully logging in to the web interface, perform related
configuration operations.
7 Specifications For more information about technical specifications of the device, refer
to the datasheets.
Item Description
Hard disk interface 16 SATA interfaces
mini SAS extended Interface
NVR516‐128‐IN can connect to two network storage expansion unit at the same time and support up to 32 hard disks
Dimensions (W × D × H)
2U high
130.5mm×477.1mm×481.6mm (with front panel)
Power supply 90V‐230V AC; 50Hz/60Hz
Consumption <200W (16 SATA Hard disks)
Working temperature ‐10℃ to +55℃
Working humidity 10% to 90% (noncondensing)
Working altitude –60m to 5000m
8 HDD Storage Calculation Chart The following chart shows an estimation of storage space used based on
recording at one channel for 24 hours at a fixed bit rate.
Table 8‐1 Storage Calculation
Bit Rate (Kbps) Storage Used (GB)
256 2.900
512 5.801
768 8.701
1024 11.602
38
Bit Rate (Kbps) Storage Used (GB)
1536 17.402
2048 23.203
3072 34.805
4096 46.406
BOM: 3101C032