nuscale power, llc - 'acrs presentation chapter 10 - steam and … · l0-0319-64787 enclosure...
TRANSCRIPT
![Page 1: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/1.jpg)
L0-0319-64787
Enclosure 1:
"ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501, Revision 1
NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928
www.nuscalepower.com
![Page 2: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/2.jpg)
PM-0219-64501
Revision: 1
NuScale Nonproprietary
NuScale FSAR Tier 2, Ch. 10 ACRS Presentation
Zack Houghton, P.E. Mechanical Design Engineering Manager
March 21st, 2019
N ~!:'.~.~!.tr Copyright 2019 by NuScale Power, LLC.
Template#: 0000-21727-F01 RS
![Page 3: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/3.jpg)
Acronyms ABS: Auxiliary Boiler System
CARS: Condenser Air Removal System
CFWS: Condensate and Feedwater System
CNTS: Containment System
· COL: Combined Operating License
CPS: Condensate Polishing System
CWS: Circulating Water System
DCA: Design Certification Application
DHR HX: Decay Heat Removal Heat Exchanger EPRI: Electric Power Research Institute FAC: Flow-accelerated Corrosion
FW: Feedwater
FWRV: Feedwater Regulation Valve
FWT : Feedwater Treatment System
GDC: General Design Criteria
HP: High Pressure
IP: Intermediate Pressure
ITAAC: Inspections, Tests, Analyses, and Acceptance Criteria
LP: Low Pressure
MC: Main Condenser
MS: Main Steam
MSIBV: Main Steam Isolation Bypass Valve
MSIV: Main Steam Isolation Valve
MSS: Main Steam System
MSSV: Main Steam Safety Valve
NEI: Nuclear Energy Institute
NS: Non safety-related
NSAC: Nuclear Safety Analysis Center
PDC: Principal Design Criteria
RG: Regulatory Guide
RIT: Radiation Indicating Transmitter
RT: Radiation Transmitter
RXB: Reactor Building
SR: Safety-related
SG: Steam generator
TEWAC: Totally Enclosed Water to Air Cooled
TG: Turbine generator
TGS: Turbine Generator System
VFD: Variable Frequency Drive
2 PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC. N ~!:'.~-~~-~.~ ..
Template#: 0000-21727-F01 RS
![Page 4: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/4.jpg)
Ch. 10 - Topics • 10.1 Summary description
• 10.2 Turbine Generator
• 10.3 Main Steam Supply System
• 10.4 Other Features of Steam and Power Conversion System
3
PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC. N !':!µ.~.!;~-~.§
Template#: 0000-21727-F01 R5
![Page 5: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/5.jpg)
Ch. 10.1 Summary Description
• The NuScale steam and power conversion system is comprised of the following systems: - Turbine generator system
- Main steam system
- Main condenser
- Condenser air removal system
- Turbine gland sealing system
- Turbine bypass system
- Circulating water system
- Condensate polishing system
- Condensate and feedwater system
- Auxiliary boiler system
- F eedwater treatment system 4
PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC. w ~!,J.?.~~.t§"
Template#: 0000-21727-F01 R5
![Page 6: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/6.jpg)
Ch. 10.1 Summary Description Figure 10.1-1: Power Conversion System Block Flow Diagram
ans
-:-+
s ; C . Cl E
SG
Removab le Spool Pieces
Seismic 'till Seismic Anchor Localed at Exl
FranRXB
MSS
ABS
Valves
Aux Steam Header 4---+'
Seismic Anchor Located al Entrance to
RXB ! Removable Spool Pieces
SG
CNt
LEGEND Steam Gererator & Aux Boiler c::::::J
Containment System -Main Steam System -
Turbine Generator System -Condensate & FeedNater System -
Condenser Air Removal System c::::::J
Turbine Bypass Valve
MSS ...+.TGS
Exhauster Packages
To Alm
Feedwater Pumps Gland Steam Condenser
5
PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC.
Feedwater
MSS
f'.", ..,. HP t "'f,. CFWS
TG
t • CFWS
To Alm
Condenser Air Removal Packages
Condensate Pumps
Nu Scale Power Cycle Block Flow Diagram
N ~!:'.?.f.~h.~ -Template #: 0000-21727-F01 R5
![Page 7: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/7.jpg)
Ch. 10.1 Summary Description
6
PM-0219-64501
Revision: 1
r- - -1
1@ I I_ - - _J
I@ I I_ - - ...J ----- --,
@
n
I I t'
,. --. ·- -. ~,----------------.
Copyright 2019 by NuScale Power, LLC.
f3 I \
I
@-- ---1 I
- - - -
W r!!:'.~.f.~.L.r Template #: 0000-21727-F01 R5
![Page 8: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/8.jpg)
Power Island Layout
7
PM-0219-64501
Revision : 1
Condenser
Copyright 2019 by NuScale Power, LLC. N ~!:'.~.~~.L..~ ..
Template#: 0000-21727-F01 R5
![Page 9: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/9.jpg)
Ch 10.2 Turbine generator system
• Converts thermal energy from SG into rotational energy
• Turbine control valves regulate steam flow from SG
• Generator directly coupled with turbine
• Vendor to be selected by COL applicant
Component
Turbine
Generator
8
PM-0219-64501
Revision : 1
Parameter
Rotor
RPM
Power Output
Cooling Type
Value
Single Turbine, 10 stage condensing
3600 rpm
50MWe
TEWAC
w ~\J.~.\:.~.L..~. Template#: 0000-21727-FO l R5
Copyright 2019 by NuScale Power, LLC.
![Page 10: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/10.jpg)
Missile Protection • Missile protection addressed in Section 3.5
- All essential equipment located inside the reactor or control buildings
- Barrier approach taken per RG 1.115 to credit reactor and control building walls as a missile barrier.
- No missile generation probability analysis or rotor integrity program credited
- Overspeed protection system similar in design to industry standard
9
PM-0219-64501
Revision : 1 Copyright 2019 by NuScale Power, LLC. w ~.!:'.?.~~-~.§
Template#: 0000-21727-F01 R5
![Page 11: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/11.jpg)
Turbine Bypass • Turbine bypass system
- Capable of supplying 100°/o rated power steam flow to main condenser
- Minimized potential for main steam release or reactor trip on load rejection
10
PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC. N ~-!Jg\~.~.§
Template #: 0000-21727-F0 1 R5
![Page 12: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/12.jpg)
10.3 Main Steam System • Main Steam System
- Delivers steam from steam generators to:
• Turbine generator
• Gland seal regulator
• Directly to condenser through bypass valve
- Provides means of dissipating residual and sensible heat generated by module during hot standby and cooldown operations by bypassing turbine to main condenser
- Transports extraction steam from turbine to feedwater heaters
11
PM-0219-64501
Revision : 1 Copyright 2019 by NuScale Power, LLC. w ~µ,~_f,~.L..§'
Template#: 0000-21727-F01 R5
![Page 13: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/13.jpg)
10.3 Main Steam System • Main Steam System Boundary
Removable Spool Pieces MSSVs
12
PM-0219-64501
Revision : 1
Seismic
Secondary Main Steam Isolation
Valves
111 Seismic Anchor Located at Exit
From RXB
v-ABS
Aux Steam Header•---.-
Copyright 2019 by NuScale Power, LLC.
MSS ...+-+TGS
a! NUSCALE .. ~ Pow ., lo • ull h,mudind
Template#: 0000-21727-F01 R5
![Page 14: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/14.jpg)
10.3 Main Steam System • Secondary steam isolations provided as backup to MSIVs
- Nonsafety-related
- Credited as backup protection for the safety-related isolations
- Periodically tested per the lnservice Testing Program
- Included within Technical Specifications
• Main Steam and Feedwater isolation valves are part of the containment system addressed in Chapter 6
13 PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC. N ~!J,~.f.~.~.~
Template #: 0000-2 1727-F01 R5
![Page 15: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/15.jpg)
10.4 Other Features • Condensate and feedwater system (CFWS)
- Supplies FW at necessary temperature, pressure, and chemistry to steam generator
- Consists of:
• Main Condenser
• Condensate storage tank
• Three feedwater pumps (2x 50°10 capacity, 1 on standby)
• Three condensate pumps (2x 50°10 capacity, 1 on standby)
• Three feedwater heaters (high, intermediate, and low-pressure)
14 PM-0219-64501
Revision : 1
• Feedwater regulating and check valves
• Condensate polishing subsystem
• Feedwater treatment subsystem
Copyright 2019 by NuScale Power, LLC. N ~Y~.~~-~r
Template #: 0000-2 1727-F01 R5
![Page 16: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/16.jpg)
10.4 Other Features • Condensate and Feedwater System Boundary
Removable Spool Pieces
Feed water Regulating Valves
CNTS ..L CFWS
15 PM-0219-64501
Revision: 1
MSS
--+ CFWS
Heater
-,- 1 FromHP t Herr CFWS
TG
t Feedwater Pumps Gland
Steam Condenser
+ CFWS
Copyright 2019 by NuScale Power, LLC.
Condensate Polisher
Skids
Condensate Pumps
w ~!:'.~.f.~.L.f Template#: 0000-21727-F0 1 RS
![Page 17: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/17.jpg)
10.4 Other Features • Feedwater Regulating Valves (FWRV) and Backup
Feedwater Check Valves
- Nonsafety-related
- Credited as backup protection for the safety-related isolations
- Periodically tested per the lnservice Testing Program
- Included within Technical Specifications
16 PM-0219-64501
Revision : 1 Copyright 2019 by NuScale Power, LLC. w !':!Y.~.~.~-~.§
Template#: 0000-21727-F01 R5
![Page 18: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/18.jpg)
10.4 Other Features • Feedwater treatment and condensate polishing
- Full flow condensate polishing
- All volatile chemistry (amine to control pH, oxygen scavenger to control dissolved oxygen)
- Controls erosion and corrosion of CFWS components by monitoring and maintaining pH and dissolved oxygen levels
- Chemistry program based on current revision of the EPRI PWR Secondary Water Chemistry Guidelines and NEI 97-06 (Steam Generator Program)
17
PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC. N ~~g-~_L,.~
Template #: 0000-21727-F01 R5
![Page 19: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/19.jpg)
10.4 Other Features • Circulating water system (CWS)
- Provides cooling water to main condenser
- Two identical circulating water systems, each providing cooling
18 PM-0219-64501
Revision: 1
water to six main condensers
Copyright 2019 by NuScale Power, LLC.
a! NUSCALe·· ~ ,owoo lo • uH h,moO'Hood
Template#: 0000-21727-F01 R5
![Page 20: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/20.jpg)
10.4 Other Features • Auxiliary boiler system (ABS)
- Supplies steam to systems when main steam is not available or not preferred
- High-pressure feeds module heatup system during startup
- Low-pressure feeds turbine gland seals, main condenser for
19
PM-0219-64501
Revision: 1
deaeration, and condensate polishing regeneration system
Copyright 2019 by NuScale Power, LLC. w ~!:'.~.~~-~~-
Template#: 0000-21727-F01 R5
![Page 21: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/21.jpg)
Ch. 10 COL Items Item No.
10.3-1
10.3-2
10.4-1
10.4-2
10.4-3
20
PM-0219-64501
Revision: 1
Description of COL Info Item
A COL applicant that references the NuScale Power Plant design certification will provide a site-specific chemistry control program based on the latest revision of the Electric Power Research Institute Pressurized Water Reactor Secondary Water Chemistry Guidelines and Nuclear Energy Institute (NEI) 97-06 at the time of the COL application.
A COL Applicant that references the Nu Scale Power Plant design certification will provide a description of the flow-accelerated corrosion monitoring program for the steam and power conversion systems based on Generic Letter 89-08 and the latest revision of the Electric Power Research Institute NSAC-202L at the time of the COL application.
A COL applicant that references the NuScale Power Plant design certification will determine the size and number of new and spent resin tanks in the condensate polishing system.
A COL applicant that references the NuScale Power Plant design certification will describe the type of fuel supply for the auxiliary boilers.
A COL applicant that references the NuScale Power Plant design certification will provide a secondary water chemistry analysis. This analysis will show that the size, materials, and capacity of the feedwater treatment system equipment and components satisfies the water quality requirements of the secondary water chemistry program described in Section 10.3.5, and that it is compatible with the chemicals used.
Copyright 2019 by NuScale Power, LLC. w ~.!J.?.~~-~.~.
Template#: 0000-21727-F01 R5
![Page 22: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/22.jpg)
Open Items Item# Summary Description
8.3-1 Related to requested exemption from GDC/PDC 34, "Residual Heat Removal ," with respect to the system function of transferring residual and sensible heat from the reactor coolant system.
21
PM-0219-64501
Revision : 1 Copyright 2019 by NuScale Power, LLC. w ~~.~.f.~!:..~ ..
Template#: 0000-21727-F01 RS
![Page 23: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/23.jpg)
Confirmatory Items (Cl) RAI
Question#
10.03.06-5
10.03.06-6
10.03.06-7
10.04.06-7
Conference Call
Conference Call
22
PM-0219-64501
Revision : 1
NRC Cl
10.3.6-1 10.3.6-3
None
10.3.6-2
None
10.4.7-1
10.4.11-1
Summary Description
Request to re-include text related to the FAC program into COL Item 10.3-2 and Section 10.3.6.3. The DCA was revised as requested .
Request to revise FSAR Tier 2, Section 10.3.6 to only discuss the nonsafety related portions of the steam and power conversion systems. The DCA was revised as requested.
Request to revise the DCD to include justification describing how the NuScale SG program meets NEI 97-6 and EPRI SG management program guidance. The DCA was revised as requested.
Request to explicitly include EPRI Action Levels for secondary water chemistry into COL Item 10.3-1. NuScale considered the COL item adequate as written .
Request to include additional discussion on the role of maintenance and operating procedures on minimizing the occurrence of water hammer. The DCA was revised as requested.
Request to remove Table 10.4-22 and specify that tanks are constructed of corrosion resistant materials compatible with chemicals used. The DCA was revised as requested .
Copyright 2019 by NuScale Power, LLC. N ~!:'.?.S~h.~ -
Template#: 0000-21727-F01 R5
![Page 24: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/24.jpg)
RAls • Unresolved Closed Question#
10.02-1
10.02-2
10.02.03-1
10.02.03-2
Summary Description
TGS - turbine overspeed trip setpoint, single failure criteria and protection against common cause failures
TGS - overspeed trip system diversity, defense-in-depth, trip logic, common components and impact of component failures
Request for ITAAC related to turbine rotor integrity/turbine missiles
Request for COL item related to a turbine inspection and testing program
• Waiting for Response/Supplemental Question# Summary Description
10.04.07-3 Request for COL item to provide operating and maintenance procedures to address water hammer issues for the CFWS
10.02-3 TGS - two independent diverse emergency overspeed protection trip systems
23 PM-0219-64501
Revision: 1 Copyright 2019 by NuScale Power, LLC. N ~!J.?.~.~.L..~ -
Template #: 0000-21727-F01 R5
![Page 25: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/25.jpg)
Portland Office 6650 SW Redwood Lane, Suite 210 Portland, OR 97224 971.371.1592
Corvallis Office 1100 NE Circle Blvd., Suite 200 Corvallis, OR 97330 541 . 360. 0500
Rockville Office 11333 Woodglen Ave., Suite 205 Rockville, MD 20852 301. 770.0472
Charlotte Office 2815 Coliseum Centre Drive, Suite 230 Charlotte, NC 28217 980. 349. 4804
Richland Office 1933 Jadwin Ave., Suite 130 Richland, WA 99354 541. 360. 0500
Arlington Office 2300 Clarendon Blvd. , Suite 1110 Arlington, VA 22201
London Office 1st Floor Portland House Bressenden Place London SW1E 5BH United Kingdom +44 (0) 2079 321700
http://www.nusca/epower.com W Twitter: @NuSca/e_ Power
24 PM-0219-64501
Revision : 1 Copyright 2019 by NuScale Power, LLC.
NUSCALE™ Powe r for a ll humankind
w ~.!:'.?.~~-~.~ Template#: 0000-21727-F01 R5
![Page 26: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/26.jpg)
25 PM-0219-64501
Revision: 1
Backup Slides
Copyright 2019 by NuScale Power, LLC. w ~!:'.~.f.~.L..§
Template#: 0000-21727-F01 R5
![Page 27: NuScale Power, LLC - 'ACRS Presentation Chapter 10 - Steam and … · L0-0319-64787 Enclosure 1: "ACRS Presentation Chapter 10 - Steam and Power Conversion System," PM-0219-64501,](https://reader035.vdocuments.mx/reader035/viewer/2022062311/5ede3ef3ad6a402d66699095/html5/thumbnails/27.jpg)
Heat Balance Figure 10.1-2: Flow Diagram and Heat Balance Diagram at Rated Power for Steam and Power Conversion System Cycle
....,._.. p,elttn M.1 pail, Adlia!II._,__.. ao f' MtiMll. ...... tuntdltt •1.,, ... M'tilfll-~~ 70 F S--~~•~ 5CM62\W S.-~lbllll,_._.,~._...,_.. 1S073C8Tl ll1
= ,00.1 T "2.1m 270.111
4.MIAp 571.Jl "2.1m 12N.5ti
/ 4.34 p
'"" ..,.,m ~--------~ 1149.5h
..... 300T 532.'>m 270.lh
26 PM-0219-64501
Revision: 1
72.llp
""" 2811 m 1UU1h
72 21p 285.2T 21.11m 2k.lh
... M0.9T 463.tm 11019h
"'"' """ 40.llffl 110011h
19.1, ,, .. , ••um .... ,. tUp ,, .. ,
456.1 ffl 7.Sp 1071.1" 179.tT
tt.8p ,, .. , Ll.11..m.
"""
9p 424.lffl 188.3 T 10ll.91'1 4561111 10l2:.lh 9 p
Ill.Sf 424.31'1 1032.8ft
,., 17911 <IW I• tCD02h
!ll7p 15UT 4148 ffl ~ .Sh
:u1p 15161 ..,.,m 1Q.!117h
3U:2p 1071 ,,um ISJ1lh
50462 kW
117 p 10,r ,ou m 971.Jh
;
..... ,o,ar 532.Sm ,..,.
.,
51
l.411p 120.31 >OUm ...,,.
3.87p ,St.al 21.1,., 275.8h
11.Hp 100.11 18l!7m ... ,, ..
437.&p 107.JT '32.lm 7tl.7h
IA2p 185.2f 3U311'1 10Jl:.6h
-- ··>------------, 141p ,,.,,
,,.. p 1II0.2f "20m 14th
.... 214.81 14 11ffl ,.,.
"'' p t l0.2: T S32.lm t,uu,
Copyright 201 9 by Nu Scale Power, LLC.
1.Up ,,.2T 02'm 1t!D.5h
. 14 1p 21152T 1.oe1"' 1100.5h
-·· i-;>------'
'51Ap 110.3T 5'UM 112311
t .3ltm l t!Kli!Jh
" 111p 1071 128.2m ,,.,
l'111p t(l).1T 11:tSlffl l&tllh
14.1p ,.,., 1ll57 m .....
373.IIP 1'117 T "2.1M 7-.1h
..... 1103T S12'M 111.2Sh
-·-
-·· 107.IT ,n:,m 76-111
l--=----1>=----1 51 3.81P 15UT t.lllm 171.th
N ~!:l.~.~~-~r Template#: 0000-21727-FOl R5