P/N 20-08808-00C 1 The TOTAL ECLIPSE Controller is an integral part of the TOTAL ECLIPSE Chemical Management System, which also includes: The Machine Interface – Accepts washer signals and converts them to safe, low-voltage inputs. The Pump Module – Provides product transfer to the wash machine. The TOTAL ECLIPSE Controller is compatible with any Nova Controls’ modular pumpstand. including the Eclipse, Orion or any of the Large Laundry dispensers. The Flush Manifold (optional) – Available for water flush chemical transfer applications. Designed for maximum versatility in OPL or large laundry machines, the TOTAL ECLIPSE Controller’s selectable Operating Modes allow the system to work with trigger signals from fully-programmable washers or with manually triggered signals (or cycle time extenders) from non-programmable, fixed-time washers. The Controller’s easy-to-understand, plain-text LCD display (available in a variety of languages), make operator training simple. Installation time and cost is significantly reduced with the computer based Formula Editor program, allowing an off-site technician to create sets of up to 20 industry-specific, efficient and cost-effective formulas that are loaded onto a controller with a customer-supplied USB flash drive (2 GB or smaller). Summary Reports can be saved to the same USB flash drive, providing usage and programming information to effectively analyze and manage each machine. Components Supplied How to Use the TOTAL ECLIPSE Quick Start Guide Use this Quick Start Guide if you are already familiar with installing and using dispensing systems. Please refer to the TOTAL ECLIPSE Reference Manual for detailed instructions, including information on the optional Relay, Event, Occurrence and Group Operating Modes. Refer also to the Installation and Operations manual that is included with your pumpstand or upgrade kit for additional instructions. IMPORTANT NOTE: Quick Start instructions assume that Formula/Setup files will be loaded via a USB flash drive, which may override the following factory default settings: Standard Operation; Eclipse Flush P.I.; Flush Time–0 sec.; Cycle Time–90 min.; Signal Filter Time–2 sec.; User Prime– Disabled; Bleach Defeat–Off; Units of Measure = SAE. Default Passwords are Installer = 01234; Manager = 0123. It is recommended that default passwords are changed via the controller’s keypad (and noted) after installation and system setup are complete. To change formulas, settings or passwords using controller keys, or to add a machine or company name, see the Guide to Keypad and Menus (p. 5) and Initial Setup on Installer Menus (p. 6). NOVA CONTROLS A SystemsCompany L E A D I N G T H E W A Y TOTAL ECLIPSE Quick Start Guide for the TOTAL ECLIPSE CHEMICAL MANAGEMENT SYSTEM TOTAL ECLIPSE Controller (P/N 01-08500-00, Grey/Teal) (P/N 01-08900-00, Black/Red) Wall Mount Bracket, Kit (P/N 13-08462-00, Grey) (P/N 13-08916-00, Black) Quick Start Guide (P/N 20-08808-00) DOWNLOAD from the Nova Controls website (http://www.novacontrols.com ): Formula Editor Software – for Windows 2000/XP/Vista, Linux & Mac OS 10.4 (Minimum requirements: Java JRE 1.5 or higher [90 MB disc space]; 1024 x 768 screen resolution; 128 MB RAM; 10 MB disc space; USB 2.0 and a USB flash drive [2GB or smaller, FAT32 format] for data transfer to TOTAL ECLIPSE controller Additional Language Files –Two Types (for Formula Editor Software and for TOTAL ECLIPSE Controller Menus ) TOTAL ECLIPSE Complete Reference Manual – at www.novacontrols.com/instructions.htm (P/N 20-08490-00) TOTAL ECLIPSE Controller Specifications Size 5.25" W x 4.0" H x 2.5" D ( 13.4 cm W x 10.2 cm H x 6.4 cm D) Weight 0.65 lb. (0.30 kg) Power Rating SELV — Power source is pumpstand Data Input Field Size 15 characters maximum input for custom names Pump Capacity 99.99 oz. (2999 ml.) 8 pump (with 3 amount settings per pump) maximum Environmental IP Rating – 44 Pollution Category – 2 Installation Category – II Temperature 10° to 49° C (50° to 120° F) maximum Humidity 95% relative humidity, maximum Indoor Installation Approved for indoor use only. Must not be installed outdoors. Altitude Install at or below 6,500 ft. (2000 m) maximum Specifications subject to change without notice. Copyright 2008 Nova Controls, Inc.

Upload: luis840zero

Post on 22-Dec-2015

50 views

Category:

Documents


2 download

DESCRIPTION

nova.

TRANSCRIPT

P/N 20-08808-00C 1

The TOTAL ECLIPSE Controller is an integral part of the TOTAL ECLIPSE Chemical Management System, which also includes: • The Machine Interface – Accepts washer signals and converts them to safe, low-voltage inputs.• The Pump Module – Provides product transfer to the wash machine. The TOTAL ECLIPSE Controller is compatible with

any Nova Controls’ modular pumpstand. including the Eclipse, Orion or any of the Large Laundry dispensers. • The Flush Manifold (optional) – Available for water flush chemical transfer applications.

Designed for maximum versatility in OPL or large laundry machines, the TOTAL ECLIPSE Controller’s selectable OperatingModes allow the system to work with trigger signals from fully-programmable washers or with manually triggered signals (or cycletime extenders) from non-programmable, fixed-time washers. The Controller’s easy-to-understand, plain-text LCD display (availablein a variety of languages), make operator training simple. Installation time and cost is significantly reduced with the computer basedFormula Editor program, allowing an off-site technician to create sets of up to 20 industry-specific, efficient and cost-effectiveformulas that are loaded onto a controller with a customer-supplied USB flash drive (2 GB or smaller). Summary Reports can besaved to the same USB flash drive, providing usage and programming information to effectively analyze and manage each machine.

Components Supplied

How to Use the TOTAL ECLIPSE Quick Start GuideUse this Quick Start Guide if you are already familiarwith installing and using dispensing systems. Pleaserefer to the TOTAL ECLIPSE Reference Manual fordetailed instructions, including information on theoptional Relay, Event, Occurrence and GroupOperating Modes. Refer also to the Installation andOperations manual that is included with yourpumpstand or upgrade kit for additional instructions. IMPORTANT NOTE: Quick Start instructionsassume that Formula/Setup files will be loaded via a USBflash drive, which may override the following factorydefault settings: Standard Operation; Eclipse Flush P.I.; Flush Time–0 sec.; Cycle Time–90 min.; Signal Filter Time–2 sec.; User Prime– Disabled;Bleach Defeat–Off; Units of Measure = SAE. Default Passwords are Installer = 01234; Manager = 0123. It is recommended that default passwordsare changed via the controller’s keypad (and noted) after installation and system setup are complete. To change formulas, settings or passwordsusing controller keys, or to add a machine or company name, see the Guide to Keypad and Menus (p. 5) and Initial Setup on Installer Menus (p. 6).

NOVA CONTROLS

A SystemsCompany

L E A D I N G T H E W A Y

TOTAL ECLIPSE Quick Start Guidefor the TOTAL ECLIPSE CHEMICAL MANAGEMENT SYSTEM

TOTAL ECLIPSE Controller(P/N 01-08500-00, Grey/Teal)(P/N 01-08900-00, Black/Red)

Wall Mount Bracket, Kit (P/N 13-08462-00, Grey) (P/N 13-08916-00, Black)

Quick Start Guide(P/N 20-08808-00)

DOWNLOAD from the Nova Controls website (http://www.novacontrols.com):• Formula Editor Software – for Windows 2000/XP/Vista, Linux & Mac OS 10.4

(Minimum requirements: Java JRE 1.5 or higher [90 MB disc space]; 1024 x 768 screen resolution; 128 MB RAM; 10 MBdisc space; USB 2.0 and a USB flash drive [2GB or smaller, FAT32 format] for data transfer to TOTAL ECLIPSE controller

• Additional Language Files –Two Types (for Formula Editor Software and for TOTAL ECLIPSE Controller Menus )• TOTAL ECLIPSE Complete Reference Manual – at www.novacontrols.com/instructions.htm (P/N 20-08490-00)

TOTAL ECLIPSE Controller Specifications Size 5.25" W x 4.0" H x 2.5" D ( 13.4 cm W x 10.2 cm H x 6.4 cm D)Weight 0.65 lb. (0.30 kg)Power Rating SELV — Power source is pumpstandData Input Field Size 15 characters maximum input for custom namesPump Capacity 99.99 oz. (2999 ml.) 8 pump (with 3 amount settings per pump) maximumEnvironmental IP Rating – 44 Pollution Category – 2 Installation Category – IITemperature 10° to 49° C (50° to 120° F) maximumHumidity 95% relative humidity, maximumIndoor Installation Approved for indoor use only. Must not be installed outdoors.Altitude Install at or below 6,500 ft. (2000 m) maximum

Specifications subject to change without notice.

Copyright 2008 Nova Controls, Inc.

2 P/N 20-08808-00C

Installation

Step 1. Install the Machine Interface (MI)

1. Route MI signal wires through 1/2 inch knock-out on washer (within the wiring area). Secure MI to washer with lock nut (provided).

2. Plug J2 cable into MI. Bundle excess J2 cable outside washer and connect other end to J2 connector on rear of Controller.

3. Connect J1 cable from pump module to J1 connector on Controller. The maximum distance for a J1 cable is 75 ft. (22.9 m.) unless using a break out box and hard wiring. Contact Nova Controls for additional cables, a coupler or detailed instructions.

4. Secure J1 and J2 cables to controller tie-down posts with tie wraps.

Step 2. Connect Signal WiresVoltage

The Machine Interface will work with any signal voltage between 24 – 240VAC or 22 – 24VDC. With DC signals, polarity must be observed. Common is negative. The signals should be positive voltages.

Supply Trigger Wiring

Identify the washer supply signals. In Standard orGroup Mode of Operation, use appropriate terminalconnectors to connect the signal wires to the MachineInterface wires, per table at right. (Do not use thistable for Event or Occurrence Modes; see Manual.)Trigger Signal Wiring Notes: • If one or more pump signals are not used, they

do not need to be connected. • If you are triggering more than one pump from a single signal, connect all MI signal wires for those pumps to that signal. • Wire nut unused wires. If washer has a single common, wire nut all commons together.

Step 3. Mount the Controller1. Mount bracket with velcro-style strips, according the directions at

right. Install wall board screws or nuts and allen bolts, if needed.2. Slide controller down onto mounting bracket until it snaps in place.3. Install pump module and make all electrical and plumbing

connections for the system, but do not apply power to the TOTAL ECLIPSE until you are ready to select a language of operation.

Controller Language Options

Each TOTAL ECLIPSE controller is shipped with two languages installed: English/Spanish (Americas); English/German (EU); or English/Simple Chinese (Asia). Additional languages may be downloaded from the Nova website directly to your USB flash drive (2GB or smaller). If changing from a default languages, you will need your language-enabled USB flash drive for the next step.

WARNING

ADVERTENCIA

Disconnect all power to the pumpstand during installation, service, and/or any time pump cabinet is opened. The TOTAL ECLIPSE should be installed by a qualified technician only, in accordance with all applicable electrical and plumbing codes.

Desconecte toda la corriente eléctrica al dosificador durante la instalación, servicio y / o siempre que se abra el gabinete de la bomba. El equipo TOTAL ECLIPSE debe ser instalado sólo por técnicos calificados y de acuerdo con todas las normas de plomería y eléctricas que apliquen.

WARNING

ADVERTENCIA

Keep MI and communication cable away from high voltage wires and relays. NEVER parallel the cable with high voltage lines.

Mantenga M.I. y los cables de comunicación separados de los cables de alta tensión y relés. NUNCA instale el cable paralelo con las líneas de alta tensión.

CAUTION

CUIDADO

Always verify all voltage sources with a meter. Electrical wiring connections for supply triggers are to be done inside the junction box.

Siempre verifique la alimentación de corriente con un voltímetro. Las conexiones eléctricas a los disparadores de suministro (supply) deben hacerse dentro del recinto donde se encuentran los suministros (supply).

TOTAL ECLIPSE Controller (Rear)

J1 Cable J2 Cable

TieWraps

MACHINE INTERFACE (Front) (Rear) Signal

WiresJ2

CableConnection

Trigger Supply Signal

Signal Common

Connect to: Standard (US) Group (EU)

Signal 1 Black wire White/Black Pump 1 Group 1

Signal 2 Brown wire White/Brown Pump 2 Group 1

Signal 3 Red wire White/Red Pump 3 Group 2

Signal 4 Orange wire White/Orange Pump 4 Group 2

Signal 5 Yellow wire White/Yellow Pump 5 Group 3

Signal 6 Blue wire White/Blue Pump 6 Group 4

Mounting Bracket3 With J1 and J2 cables connected, slide Controller onto mounting bracket until it snaps into place.

1 Attach Velcro-style Strips and Mount

Install Wall Board Screws or Masonry Nuts & Allen Bolts

2 (Optional)

P/N 20-08808-00C 3

Step 4. Select the Controller Menu Language (Before Applying Power)1. To select one of the pre-installed languages, skip to Step 2. To replace the non-English

language with a different language, connect a USB flash drive containing the new languageto the controller’s USB port (under flap on right side of controller) BEFORE power-up.

2. Apply power to pumpstand & power-up Controller. Each available LANGUAGE is displayed. 3. Move the selection box by using the UP or DOWN ARROWS until the correct

language is contained within the box. 4. Press Enter to select that language. All menu and application items are translated into

the new language. Text that was input by the installer remains in the original language and is not translated.5. The Home Screen appears. You must now program the controller with formula and operational set-up files, using either a USB

flash drive or the controller’s keypad.

Step 5. Program the Controller via USB Flash DriveThe easiest way to program the controller is by loading previously created set-up files from a USB flash drive onto the controller. Settings that are not transferred via a USB drive are: Passwords (Installer & Manager); Machine Name; Company Name; Calibration.

1. Connect the USB flash drive containing set up files that were created in either the Formula Editor or on another controller.2. From the Home Screen, press ENTER to launch the MAIN MENU.3. Move the selection box to INSTALLER MENU (last item in the MAIN MENU) by pressing and holding the DOWN ARROW.4. Press ENTER and input the default Installer Password of 01234, using the UP ARROW to increment the number and the

RIGHT ARROW to move the cursor. 5. Press ENTER to accept the password input. Continue with Steps 3, 4, and 5 in the sequence illustrated below.6. Remove USB flash drive. Press EXIT to return to the Installer Menu, in order to calibrate (required) and prime pumps

Step 6. Prime PumpsPress Enter to start and stop prime. After priming is complete, press the EXIT KEY until you reach the Home Screen.

Step 7. Calibrate PumpsYou must calibrate all pumps that will be used in a formula. Programmed formulas will not run if pumps are not calibrated. Use CALIBRATE (VOLUME) only for medium (12 or 18 oz. / 355 or 532 ml. per minute) pumps.

EXIT ENTERUP

DOWN

RIGHTLEFT

TOTAL ECLIPSE Keypad(Press & Hold for Auto-Key Repeat)

01234

OK EXIT

1. Select Installer Menu

MAIN MENUEMERGENCY PUMP STOPLOAD SIZE: 200 LB BLEACH DEFEAT: OFFUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS �INSTALLER MENU

Default Home Screen

INSTALLER MENUINSTALLER SERVICEINITIAL SYSTEM SETUPPROGRAM FORMULASDATA TRANSFERSET UNITS OF MEASURE

3. Select Data Transfer2. Input Password

INSTL PASSWORD SETUP FILEPOG RestaurantsBLS ServicesEclipse HotelHospital SettingsInternational HotelAA School District

DATA TRANSFERWRITE REPORTSREAD SETUPWRITE SETUPUPDATE FIRMWARE

OK EXIT

4. Display Files on USB 5. Send File to Controller

��NOVA CONTROLS

F01

INSTALLER SERVICESERVICE PUMPSVIEW LOAD COUNTVIEW LOAD WEIGHTVIEW AMOUNT PUMPEDCLEAR DATA LOG

INSTALLER MENUINSTALLER SERVICEINITIAL SYSTEM SETUPPROGRAM FORMULASDATA TRANSFERSET UNITS OF MEASURE

1. Select Installer Service 3. Select Prime Pump

SERVICE PUMPSPRIME PUMPPUMP CALIBRATIONNAME PUMPSENTER PRODUCT COSTSDATE TUBE CHANGED

SET PRIME PUMPP1P2P3P4P5P6

5. Select Pump to PrimePRIME

P2

START/STOP EXIT

6. Start/Stop Prime2. Select Service Pumps

CALIBRATE (TIME)P1P2P3P4P5P6

DISPENSED VOLUMEENTER AMOUNT PUMPED

00.0 OZ

OK EXIT

6.1 Input Amount Collected

CALIBRATEP2 0.0 20.0WARNING! PLACECONTAINER AT OUTPUT! START/STOP EXIT

6. Run Pump Full 20 Seconds

INSTALLER SERVICESERVICE PUMPSVIEW LOAD COUNTVIEW LOAD WEIGHTVIEW AMOUNT PUMPEDCLEAR DATA LOG

INSTALLER MENUINSTALLER SERVICEINITIAL SYSTEM SETUPPROGRAM FORMULASDATA TRANSFERSET UNITS OF MEASURE

1. Select Installer ServicePUMP CALIBRATIONVIEW CALIBRATIONCALIBRATE (TIME)CALIBRATE (VOLUME)

4. Select Calibration Method3. Select Pump Calibration

SERVICE PUMPSPRIME PUMPPUMP CALIBRATIONNAME PUMPSENTER PRODUCT COSTSDATE TUBE CHANGED

CALIBRATE (VOL.)P1P2P3P4P5P6

5. Select Pump to Calibrate

5. Select Pump to Calibrate

CALIBRATEP2 STOP PUMP AT 8 OZ

WARNING! PLACECONTAINER AT OUTPUT! START/STOP EXIT

6. Collect 8 oz [250 ml]2. Select Service Pumps

Use CALIBRATE (TIME) for large displacement pumps or for a flush installation. Press START and the timer counts down 20 seconds. DO NOT stop the pump; run it for a full 20 seconds, then enter the amount pumped.

4 P/N 20-08808-00C

Home Screen

The Home Screen appears after the controller language has been selected or whenever the controller is active. If no key is pressedfor 15 minutes, Power Save turns off the display’s backlight. Press any key to turn the backlight on and resume normal operation.If the controller is powered off, the last formula selected is the active formula on the Home Screen when power is turned backon. See the following graphic for an explanation of the information and symbols that may appear on the Home Screen.

Formula Quick-Select

To prevent errors in data logging or chemical dispensing: Select the correct formula before washer operation starts and be sure that all programmed pumps are triggered during the cycle.

1. From the Home Screen, press the EXIT key (also called FORMULA SELECT). 2. Press the UP or DOWN ARROW to move the selection box to the correct formula.

All formulas appear, but only formulas with programmed pumps are selectable. 3. Press ENTER to start the formula and return to the Home Screen.4. (Optional) Press ENTER to reach the load size or bleach defeat settings.

Main Menu

To reach the Main Menu from the Home Screen, press any key (except the EXIT key).

Limited WarrantySELLER warrants solely to BUYER the Products will be free from defects in material and workmanship under normal use and service for a period of one yearfrom the date of completion of manufacture. This limited warranty does not apply to (a) hoses; (b) and products that have a normal life shorter than one year; or(c) failure in performance or damage caused by chemicals, abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misap-plication. In the event the Products are altered or repaired by BUYER without SELLER’S prior written approval, all warranties will be void. NO OTHER WAR-RANTY, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULARPURPOSE, IS MADE FOR THESE PRODUCTS, AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY EXCLUDED. SELLER’S sole obligation under this warranty will be, at SELLER’S option, to repair or replace F.O.B. SELLER’S facility in Watsonville, California any Productsfound to be other than as warranted.Limitation of LiabilitySELLER’S WARRANTY OBLIGATIONS AND BUYERS REMEDIES ARE SOLELY AND EXCLUSIVELY AS STATED HEREIN. SELLER SHALL HAVENO OTHER LIABILITY, DIRECT OR INDIRECT, OF ANY KIND, INCLUDING LIABILITY FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIALDAMAGES OR FOR ANY OTHER CLAIMS FOR DAMAGE OR LOSS RESULTING FROM ANY CAUSE WHATSOEVER, WHETHER BASED ONNEGLIGENCE, STRICT LIABILITY, BREACH OF CONTRACT OR BREACH OF WARRANTY.

NON-ACTIVE Pump – Not programmed or calibrated; not in formula

ACTIVE Pump – Currently running

READY Pump – Calibrated and has amount(s) programmed

ERROR in Pump – Amount(s) programmed; not calibrated

NOVA CONTROLS F03 TOWELS

_ _ 4 _ _ 2

1 2 _ 5 6

Hot Keys: Formula Quick-Select Main Menu

Company Name (can be changed during System Setup)

Current Formula (or Next Formula to Run) (Formula number appears if no name is input during System Setup)

QualifiedSignal

Home Screen

Pumps

TriggerSignals

ReceivingSignal

(unqualified)

Non-ActiveSignal

SELECT FORMULAFO1 PADSF02 CURTAINSFO3 TOWELSF04 BED LINENF05 BLANKETSF06 TABLE LINEN

Formula Quick-Select

Move Box Select Formula

NOVA CONTROLSF03 TOWELS

1 2 3 4 5 6

_ _ 3 _ _ _

EMERGENCY PUMP STOPLOAD SIZE 075 LBBLEACH DEFEAT OFFUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS

INSTALLER MENU

MAIN MENU

• Emergency Pump Stop (stops all pumps and formulas)

• Load Size Menu (displays default load weight for formula. Input actual weight at start of each load).

• Bleach Defeat Menu (default is OFF)

• Selection Box – Move box to select menu item.

Press ENTER to launch selected menu

• More Items Available (move Selection Box to view additional menus)

Main Menu

Return to Home Screen: Press EXIT or wait 15 seconds without pressing a key.

P/N 20-08808-00C 5

TOTAL ECLIPSE Operator Menus

NOVA CONTROLS

F02 CURTAINS

_ 2 _ _ _ _ �

EMERGENCY PUMP STOPLOAD SIZE 275 LBBLEACH DEFEAT OFFUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS

INSTALLER MENUS

Main MenuMAIN MENU

SELECT FORMULAF01 PADSF02 CURTAINSF03 TOWELSF04 BED LINENF05 BLANKETSF06 TABLE LINEN

Formula Select

Select& Returnto HomeScreen

Home Screen

LOAD WEIGHT

220 LB

(SINGLE LOAD) OK EXIT

Input Actual Load Weight

SET PRIME PUMPP1 PRE-WASHP2 DETERGENTP3 LIQUID BLEACHP4 BLEACH ALTERNATIVEP5 SOUR/CONDITIP6 ENZYME LIFT

Bleach Defeat On/Off (Default Off)

Emergency Pump Stop

MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 220 LBBLEACH DEFEAT ONUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS

Main Menu (User Prime Pump)

MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 220 LBBLEACH DEFEAT OFFUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS

Main Menu (Bleach Defeat)

MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 275 LBBLEACH DEFEAT OFFUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS

Main Menu

BLEACH DEFEATOFFON

(SINGLE LOAD)

OK EXIT

EMERGENCY STOP

STOP ALL PUMPSAND FORMULAS

STOP EXIT

PRIME P3 LIQUID BLEACH

START/STOP EXIT

Select Pump to Prime (if enabled) Start / Stop Prime Pump

MGR PASSWORD

OK EXIT

Input Manager Password

0 1 2 3�

�00-00-00�

REPORT DATE

OK EXIT

Set Date for Report Header

WASH23 12-10-08

INSERT USB DRIVE

REPORT NAME

OK EXIT

Set “SAVE AS” File Name & Date

MANUAL FLUSH

START/STOP EXIT

Start/Stop Flush (if flush enabled)

�MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 220 LBBLEACH DEFEAT ONUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS

Main Menu (User Manual Flush)

�MAIN MENUEMERGENCY PUMP STOPLOAD SIZE 220 LBBLEACH DEFEAT ONUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTS

Main Menu (Manager Reports)

Display returns to Main Menu after data transfer is complete.

1 2 3 X 5 6 7 8 8

�MAIN MENULOAD SIZE 180 LBBLEACH DEFEAT OFFUSER PRIME PUMPSUSER MANUAL FLUSHMANAGER REPORTSINSTALLER MENUS

INSTL PASSWORD

0 1 2 3 4

OK EXIT

Installer Menu Access

Guide to Keypad & Menus

Pumping(Flush Off)

More Items Flushing Pumping &Flushing

F02 �FO3 FO4 �

SELECTIONBOX UP/DOWN

Arrows MoveSelection Box

ENTER KeyLaunchesMenu Item

ENTER also Starts/Stops

Action

MENUSYMBOLS

HOMESCREEN

=

or

UP/DOWNArrows Input

Value (0-9, A-Z)

LEFT/RIGHTArrows Move

Cursor

ENTERSaves & Exits

EXITOnly

350 LBS�

EDITVALUE

=

Steady On

Trigger Signal IconPump Icon

6 P/N 20-08808-00C

01

234

O

K

E

XIT

Mai

n M

enu

MA

IN M

EN

ULO

AD

SIZ

E:

1

75 L

BB

LEA

CH

DE

FE

AT:

OF

FU

SE

R P

RIM

E P

UM

PS

US

ER

MA

NU

AL

FLU

SH

MA

NA

GE

R R

EP

OR

TS

INS

TALL

ER

ME

NU

S

Hom

e S

cree

n

INS

TAL

LE

R M

EN

UIN

STA

LLE

R S

ER

VIC

EIN

ITIA

L S

YS

TE

M S

ET

UP

PR

OG

RA

M F

OR

MU

LAS

DAT

A T

RA

NS

FE

RS

ET

UN

ITS

OF

ME

AS

UR

E

Inst

alle

r Top

Lev

el M

enu

Inpu

t Ins

talle

r P

assw

ord

INS

TL

PA

SS

WO

RD

UN

ITS

-ME

AS

UR

ES

AE

/ IM

PE

RIA

L (

LB/O

Z)

ME

TR

IC

(K

G/M

L)

5.

Set

Uni

ts o

f M

easu

re

NO

VA C

ON

TR

OL

S F

03 T

OW

EL

S

_

_

4 _

_

2

1 2

3

_

_

3.1.

2 A

dd P

umps

to F

orm

ula

F01

PU

MP

SP

1 P

RE

-WA

SH

P2

DE

TE

RG

EN

T

P3

LIQ

UID

BLE

AC

H

P4

BLE

AC

H A

LT

P5

SO

UR

/CO

ND

ITI

P

6 E

NZ

YM

E L

IFT

3.1.

3 P

ump

Set

tings

F01

P1

P1

D

ELA

Y

0 0

0 S

EC

P1A

AM

OU

NT

0

0.00

OZ

P1B

AM

OU

NT

0

0.00

OZ

P1C

AM

OU

NT

0

0.00

OZ

PR

OG

RA

M F

OR

MU

LAS

F01

F02

CU

RTA

INS

F03

TO

WE

LS

F04

BE

D L

INE

N

F

05 B

LAN

KE

TS

F06

TA

BLE

LIN

EN

3. F

orm

ula

Pro

gra

mm

ing

F01

PU

MP

SE

TT

ING

S

SE

T D

EFA

ULT

WE

IGH

TS

ET

CO

UN

T P

UM

PE

DIT

NA

ME

CLE

AR

FO

RM

ULA

3.1

Set

For

mul

a3.

2 D

efau

lt Lo

ad W

eigh

t3.

3 S

et C

ount

Pum

p3.

4 E

dit F

orm

ula

Nam

e3.

5 C

lear

For

mul

a

PO

G R

esta

uran

tsB

LS S

ervi

ces

Ecl

ipse

Hot

elH

ospi

tal S

ettin

gsIn

tern

atio

nal H

otel

AA

Sch

ool D

istr

ict

SE

TU

P F

ILE

4.2

Rea

d S

etup

- S

elec

t File

to

load

from

US

B to

Con

trolle

r4.

3 W

rite

Set

up -

Nam

e Fi

le b

eing

sen

t

(fro

m C

ontro

ller t

o U

SB

flas

h dr

ive)

DA

TA T

RA

NS

FE

RW

RIT

E R

EP

OR

TS

RE

AD

SE

TU

PW

RIT

E S

ET

UP

UP

DAT

E F

IRM

WA

RE

4.1

Set

Dat

e fo

r Rep

ort H

eade

r

RE

PO

RT

DA

TE

01-

01-0

8

O

K

EX

IT

RE

PO

RT

NA

ME

_DA

TE

HI-

CA

P 0

1-01

-08

INS

ER

T U

SB

DR

IVE

O

K

EX

IT

4.1.

2 S

et “S

AV

E A

S”

F

ile N

ame

& D

ate

4. U

ploa

d /

Dow

nloa

d D

ata

1.5

Cle

ar D

ata

Log

ZE

RO

DA

TA L

OG

WA

RN

ING

! ALL

LO

GS

(LO

AD

S &

VO

LUM

ES

)W

ILL

BE

CLE

AR

ED

!

O

K

E

XIT

1. S

ervi

ce /

Rou

tine

Mai

nten

ance

INS

TAL

LE

R S

ER

VIC

ES

ER

VIC

E P

UM

PS

VIE

W L

OA

D C

OU

NT

VIE

W L

OA

D W

EIG

HT

VIE

W A

MO

UN

T P

UM

PE

DC

LEA

R D

ATA

LO

G

1.1

Pum

p M

aint

enan

ce /S

ervi

ce

SE

RV

ICE

PU

MP

SP

RIM

E P

UM

PP

UM

P C

ALI

BR

ATIO

NN

AM

E P

UM

PS

EN

TE

R P

RO

DU

CT

CO

ST

SD

ATE

TU

BE

CH

AN

GE

D

1.2

Vie

w L

oad

Cou

nt

TOTA

L L

OA

D C

OU

NT

F01

PA

DS

0

F02

CU

RTA

INS

0F

03 T

OW

ELS

0

F04

BE

D L

INE

N

0F

05 B

LAN

KE

TS

0

F06

TA

BLE

LIN

EN

0

1.3

Vie

w L

oad

Wei

ght

TOTA

L W

EIG

HT

F01

PA

DS

0

F02

CU

RTA

INS

0F

03 T

OW

ELS

0

F04

BE

D L

INE

N

0F

05 B

LAN

KE

TS

0

F06

TA

BLE

LIN

EN

0

1.4

Vie

w A

mou

nt P

umpe

d

PU

MP

ED

(G

AL

)P

1 P

RE

-WA

SH

0.0

P

2 D

ET

ER

GE

NT

0

.0P

3 LI

QU

ID B

LEA

C

0.0

P4

BLE

AC

H A

LT

0.

0P

5 S

OU

R/C

ON

DIT

I

0.0

P6

EN

ZY

ME

LIF

T

0.0

0 1

2 3

4

O

K

EX

IT

INS

T P

AS

SW

OR

D

MG

R P

AS

SW

OR

D2.

5 E

dit M

achi

ne N

ame

2.1

Edi

t Ins

talle

r Pas

swor

d2.

2 E

dit M

anag

er P

assw

ord

2.3

Set

-up

Ope

ratin

g M

ode

HO

TE

L E

CLI

PS

E -

67

O

K

EX

IT

AC

CO

UN

T N

AM

E2.

4 E

dit A

ccou

nt N

ame

2.6

Edi

t Com

pany

Nam

e

2.8

Set

Cyc

le T

ime

Lim

it

9 0

MIN

UT

ES

(0 =

OF

F)

O

K

EX

IT

CY

CL

E T

IME

LIM

IT2.

9 S

et T

rigge

r Sig

nal F

ilter

2 S

EC

ON

DS

10 S

EC

ON

DS

20 S

EC

ON

DS

30 S

EC

ON

DS

60 S

EC

ON

DS

90 S

EC

ON

DS

TR

IGG

ER

FIL

TE

R2.

10 A

uto-

Form

ula

Sel

ect

2.11

Use

r P

rime

Ena

ble

2.12

Adj

ust S

cree

n C

ontra

st2.

13 C

lear

Con

trolle

r Set

tings

SY

ST

EM

SE

TU

PE

DIT

INS

T P

AS

SW

OR

D

ED

IT M

GR

PA

SS

WO

RD

O

PE

RAT

ION

MO

DE

ED

IT A

CC

OU

NT

NA

ME

ED

IT M

AC

HIN

E N

AM

EE

DIT

CO

MPA

NY

NA

ME

SE

T P

UM

P IN

TE

RFA

CE

SE

T C

YC

LE T

IME

SIG

NA

L F

ILT

ER

TIM

ES

ET

AF

S T

RIG

GE

RS

ET

US

ER

PR

IME

SE

T L

CD

CO

NT

RA

ST

CLE

AR

SE

TT

ING

SV

IEW

SO

FT

WA

RE

ID

� �

2. I

niti

al S

yste

m S

etu

p

2.14

Sof

twar

e Ve

rsio

n ID

TOTA

L E

CLI

PS

EP

/N:

95-0

8489

-00A

RE

V:

687

SO

FT

WA

RE

VE

R

SE

TU

P N

AM

E

H

OT

EL

17

INS

ER

T U

SB

DR

IVE

O

K

EX

IT

STA

ND

AR

DR

ELA

YE

VE

NT

GR

OU

PO

CC

UR

RE

NC

E

OP

ER

AT

ION

MO

DE

2.7

Set

Pum

p In

terfa

ce

(and

Flu

sh T

ime,

if n

eede

d)

NO

N-F

LUS

HE

CLI

PS

E F

LUS

H P

. I.

OR

ION

I I

FLU

SH

P. I

.8-

PU

MP

FLU

SH

P. I

.

PU

MP

INT

ER

FAC

E

Ove

rwrit

es fi

le of

sam

e na

me o

n U

SB fl

ash

driv

e. D

oes n

ot tr

ansfe

r pas

swor

ds,

mac

hine

nam

e, co

mpa

ny

nam

e or c

alib

ratio

ns.

Ove

rwrit

es A

LL se

tting

s &

form

ulas

, exc

ept p

assw

ords

, m

achi

ne n

ame,

com

pany

na

me &

cal

ibra

tions

.

WA

RN

ING

! ALL

SE

TU

PS

W

ILL

BE

CLE

AR

ED

TO

FAC

TOR

Y D

EFA

ULT

S!

O

K

EX

IT

CL

EA

R S

ET

TIN

GS

F01

LO

AD

SIZ

E

0 0

0 L

B

O

K

E

XIT

NA

ME

F01

NE

W N

AM

E

O

K

EX

IT

P2

DE

TE

RG

EN

T

P

3 LI

QU

ID B

LEA

CH

P

4 B

LEA

CH

ALT

P

5 S

OU

R/C

ON

DIT

I

P6

EN

ZY

ME

LIF

TP

7

F01

CO

UN

T P

UM

PC

LE

AR

F01

WA

RN

ING

! FO

RM

ULA

W

ILL

BE

CLE

AR

ED

TO

FAC

TOR

Y D

EFA

ULT

!

O

K

E

XIT

4.4

Upd

ate

Firm

war

e

UP

DA

TE

FIR

MW

AR

E

STO

P!!!

DO

NO

TP

RO

CE

ED

WIT

HO

UT

PC

UP

DAT

E P

RO

GR

AM

!

O

K

EX

IT

0

(0

= O

FF

)

OK

E

XIT

AF

S T

RIG

GE

RD

ISA

BLE

EN

AB

LELI

MIT

ED

30

SE

C

O

K

EX

IT

SE

T U

SE

R P

RIM

E

��

5 0

O

K

EX

IT

LC

D C

ON

TR

AS

T

0

1 2

3

O

K

EX

IT

H

OU

SE

KE

EP

ING

01

O

K

EX

IT

�MA

CH

INE

NA

ME

N

OVA

CO

NT

RO

LS

O

K

EX

IT

CO

MPA

NY

NA

ME

WA

RN

ING

! D

O N

OT

atte

mpt

firm

war

e up

date

unl

ess

you

have

you

rP

C U

pdat

e P

rogr

am a

nd

prop

er c

ompu

ter

cabl

e.

Ent

er /

Sav

e K

ey- L

aunc

hes

sele

cted

men

u ite

m- S

aves

cha

nges

& e

xits

men

u

Up

/ Dow

n A

rrow

- Mov

es S

elec

tion

Box

- Cha

nges

dig

it va

lue

Rig

ht /

Left

Arr

owD

urin

g in

put,

mov

es th

ecu

rsor

( )

to th

e ne

xt d

igit

� �

TOTA

L E

CL

IPS

E T

op

Lev

el In

stal

ler

Men

us

(fac

tory

def

ault

setti

ngs

show

n in

sel

ectio

n bo

xes)

N OVA C O N T RO L S

A Systems Company www.novacontrols.com831.786.1470�800.252.NOVA (6682)�FAX: 831.786.1652225 Westr idge Drive, Watsonville, California, USA 95076-4168