notice of application for category 3 development ... · development no: 960/709/2016 . nature of...
TRANSCRIPT
DEVELOPMENT NO: 960/709/2016 NATURE OF THE DEVELOPMENT: Variation to Development Application
960/611/2014 - Wine Interpretative Centre (Cultural and Exhibition Facility)
SUBJECT LAND: Allot 500 Stockwell Road, VINE VALE
Notice of Application for Category 3 Development Development Act 1993
This application can be viewed at The Barossa Council Office, 43-51 Tanunda Road, Nuriootpa during business hours. Anyone affected may make written representations regarding the application. Representations must be addressed to the Chief Executive Officer, The Barossa Council, PO Box 867, Nuriootpa SA 5355 or emailed to [email protected], and received not later than 5.00pm 21 December 2016. If anyone making a representation wishes to be heard by Council’s Development Assessment Panel they must indicate this in their representation. Copies of representations will be forwarded to the applicant for their response and may be publicly available in report documents.
p l a n n i n g a p p l i c a t i o n s u b m i s s i o n
project: The Barossa Cellar – Wine Interpretative Centre, Cultural + Exhibition Facility
job no: 1341
date issued: 25.10.16
r e s i d e n t i a l c o m m e r c i a l w i n e r y p l a n n i n g a r c h i t e c t u r a I i n t e r i o r l a n d s c a p e
38 Murray St Tanunda SA
www.jbgarchitects.com
ABN 31 852 116 195
1341.04.PA Submission.revised.161025 1 of 2
Attention: Karen Mitrovic
We submit the following revisions for the above project for previously approved DEVELOPMENT NO:
960/611/2014 .
Generally, building exposure, patron numbers and daily operation is within 10% variation to the previously
approved development.
General Project Variations:
Since approval in February 2015, design for The Barossa Cellar has developed resulting in various new
operational and storage requirements summarised as follows –
- Incorporation of not-for-profit community organisation Barossa Grape + Wine Association (BGWA) has
led to the originally approved office component increasing to 106sqm, less than 10% of total building
area 1076 sqm.
- Wine industry support has resulted in wine storage requirements increasing to 444sqm.
These variations have been carefully integrated without significant increase to building presence as much of
the additional area is located behind the façade and excavated into the hillside. The cellar component is still
fully underground while The Grand Hall roof follows the natural slope and will now accommodate solar panels.
Visible frontage is now 36.4m up from 32.5m. Building materials remain local stone, wood and earth-coloured
rendered masonry.
Activity/Development Definition:
The following Activity Definition has been updated since previously approved to include anticipated BGWA
operational activities -
1. The expected level of activity and hence traffic movement per year is as follows –
(no change to the following)
- monthly Barons Grand Council meetings (up to 8 persons – say, 8 vehicles). (no change)
- 6 Master classes (up to 24 persons – small bus)
- Miscellaneous visits by Barons for wine curating, administration etc. which would be ongoing on a
daily or weekly basis. ) (no change)
- Up to 30 deliveries of small parcels of wine for storage (end of vintage)
- Small tourist buses by special appointment (it is expected that this will be minimal).
(minor change to the following)
- 6 major events (up to 90 persons – say, 40 vehicles, small bus). (up from 4)
- The previously approved Administration Office was designed to accommodate up to 5 staff and
attract visitors for meetings within expectations of a typical administrative facility. BGWA anticipate 4
full time staff and 2 part time staff generally during normal office hours 9am-5pm and up to 5 meetings
with staff per week on average (total 6-8 persons – say, 7 vehicles daily)
Additional activity associated with BGWA tenancy are within typical expectations of a successful Wine
Interpretative Centre, Cultural and Exhibition Facility, and are summarised as follows –
- monthly BGWA Board and Committee meetings per year (8-12 persons – say, 12 vehicles)
- 10 workshops/working group meetings per year. Duration 2-3 hours during working hours. (up to 40
persons – say, 40 vehicles, small bus)
- 4-6 tastings with international visitors per year (up to 24 persons – small bus)
- Education and training services offered by BGWA (small groups dependant on international visitor
program with Wine Australia – small bus)
j b g a r c h i t e c t s . c o m quality assurance system
38 Murray St Tanunda SA
www.jbgarchitects.com
ABN 31 852 116 195
1341.04.PA Submission.revised.161025 2 of 2
- One main delivery of wine in September each year at the conclusion of the Barossa Wine Show.
- Some infrequent deliveries of wines happen according to tasting program.
The BGWA does not offer a retail wine service. It is not a tourism body open to general visitors to the region but
service trade and media visitors and our grape growing and winemaking membership.
Please click here to view the 2015-16 BGWA Annual Report, which provides a comprehensive overview of the
Association’s activities.
- http://www.barossa.com/uploads/203/bgwa-annual-report-2015-16-final-reduced.pdf
- http://www.barossa.com/members/barossa-grape-and-wine-association/agm
Documents:
Architectural drawings ; A000.C, A002.C, A101.C, A201.C, A301.A
Please contact the undersigned with any queries.
Regards
JBG Architects Pty Ltd
Jamie Gladigau - Project Director
encl.
3 copies each of dwg
STO
CK
WELL
RO
AD
PROPOSED SITE
EXISTING HOUSE
EXISTING HOUSES
O/A
SIT
E B
DR
Y 1
64.7
0
O/A SITE BDRY 186.000
O/A SITE BDRY 186.000
O/A
SIT
E B
DR
Y 1
64.7
0
120m x 30m
MARQUE
30m x 35m LAWN
SITE
ENTRY / EXIT
SITE
ENTRY / EXIT
SIT
E B
OU
ND
ARY
164.7
0
SITE BOUNDARY 93.000
VINES
SITE BOUNDARY 93.000
PROPOSED
DEVELOPMENT
10000
~23000
51100
62400
51100
EQ
EQ
Issue
NOTES
Issued For By Chkd Date
This drawing is copyright and the property of JBG Architects Pty. Ltd. and must not be used without written authorisation. Do not scale this
drawing. All dimensions shown on drawings are in millimetres unless otherwise noted and should be verified on site before commencing building works. These architectural drawings are to be read in
conjunction with the building specification and consultant drawings. Any discrepancies are to be referred to the project architect for clarification prior to work commencing.
ABN 31 852 116 195
© c
op
yrig
ht
JB
G A
rch
ite
cts
Pty
. Ltd
. A
ll rig
hts
re
serv
ed
Drawing Number Issue
Project Number
Project Address
Drawing Title
J B G ARCHITECTS PTY LTDresidential - commercial - winery - planning - architecture - interiors - landscape
38 MURRAY STREETTANUNDA 5352
Architect
Client
P. 08 8563 1155
NOT FOR CONSTRUCTION
AHRENS GROUPWilhelm RoadKingsford SA 5118P. 08 8521 0000 E. [email protected]
PTY LTD
CA000
1341
COVERSHEET,PERSPECTIVE +BLOCK PLAN
1015 STOCKWELL ROADVINE VALE, SOUTH AUSTRALIA 5352
T H E B A R O S S A C E L L A RWINE INTERPRETATIVE CENTREARCHITECTURAL DRAWING LISTDWG No. DWG CONTENT ISSUE DATE ISSUED FOR
A000 COVERSHEET, PERSPECTIVE + BLOCK PLAN C 25.10.16 CLIENT REVIEW / PLANNING
A002 SITE PLAN C 25.10.16 CLIENT REVIEW / PLANNING
A101 FLOOR PLAN - PRESENTATION C 25.10.16 CLIENT REVIEW / PLANNING
A201 ELEVATIONS - PRESENTATION C 25.10.16 CLIENT REVIEW / PLANNING
A301 SECTIONS - PRESENTATION A 25.10.16 CLIENT REVIEW / PLANNING
0 10m 30m 40m 50m
1:1000 @ A1, 1:2000 @ A3
20m 1 : 1000A201
BLOCK PLAN1
A CLIENT REVIEW WS JG 05.10.16
B BUILDER REVIEW WS JG 10.10.16
C CLIENT REVIEW / PLANNING WS JG 25.10.16
ADDRESS: 1015 STOCKWELL ROADVINE VALE, SA, 5352
HUNDRED: MOOROOROO
TITLE REF: CT5950/517PLAN PARCEL: D65689 A3
VIEW FROM STOCKWELL ROAD2
VIEW FROM DRIVEWAY3
AERIAL VIEW4
-1200
0
-110
00
-10000
-9000
-8000
-7000
-600
0
-500
0
-4000
317,500
318,500
319,500
320,500
321,50
0
322,5
00
323,50
0
324,50
0
325,500
326,500 -3000
-2000
-1000
0
1000
2000
3000
4000
5000
6000
7000
8000
9000
100
00
11000
12000
130
00
-4000
-3000
-2000
-100
0
0
10
00
20
00
30
00
40
00
500
0
60
00
70
00
80
00
90
00
10
000
11
000
12
000
130
00
-12000
-11000
-10000
-9000
-8000
-7000
-6000
-5000
317,500
318,500
319,500
320,500
321,500
322,500
323,500
324,500
325,500
326,500
327,500
328,500
329,5
00
33
0,500
33
1,50
0
33
2,5
00
333
,50
0
334
,50
0
33
5,50
0
336
,50
0
33
7,5
00
338
,500
339
,500
340
,500
341
,500
342,50
0 327,500
328,500
329,500
330,500
332,500
333,500
334,500
335,500
336,500
337,500
338,500
339,500
340,500
341,50
0
331,500
S T
O C
K W
E L
L R
O A
D
20m x 30m
MARQUE
25m x 35m LAWN
DRIV
E W
AY
12 CARPARKS
13 CARPARKS
DRIVE WAY
12 CARPARKS
13 CARPARKS
PATH
SITE
ENTRY / EXIT
SITE
ENTRY / EXIT
EARTH EMBANKMENT
EARTH EMBANKMENT
ENTRY
LOADING
ZONE
LOADING
ZONE
DROP-OFF
ZONE
SIT
E B
OU
ND
ARY
164.7
0
SITE BOUNDARY 93.000
RETA
ININ
G W
ALL
ENTRY
DISABLED CARPARK +
SHARED ZONE
DISABLED CARPARK +
SHARED ZONE
SITE BOUNDARY 93.000
EARTH ROOF
ROAD ACCESS + DRAINAGE IN ACCORDANCE WITH COUNCIL
ENGINEERING + A.S. REQUIREMENTS
ROAD ACCESS + DRAINAGE IN ACCORDANCE WITH
COUNCIL ENGINEERING + A.S. REQUIREMENTS
STORMWATER MANAGEMENT + SCREENING MOUND
LANDSCAPE; SCREEN TO CONSIST OF TREES, SHRUBS +
GROUND COVERS
CONCEALED PLANT AREA INCLUDING WATER STORAGE
HEADER TANK
STORMWATER MANAGEMENT + SCREENING MOUND
LANDSCAPE; SCREEN TO CONSIST OF TREES, SHRUBS +
GROUND COVERS
SECURITY LIGHT
SECURITY LIGHT
EARTH EMBANKMENT
VINES
PHOTOVOLTAIC CELLS ON ROOF
900 HIGH STONE ENTRY
STATEMENT BLADE WALLS
900 HIGH STONE ENTRY
STATEMENT BLADE WALLS
10000
~23000
51100
62400
51200
7000
48400
7000
1
A301
CONCEALED PLANT AREA
(1797)
EQ
EQ
NORTH0
WEST270
EAST90
SOUTH180
JUNE 22
DECEMBER 22
5
12
8
12
5
7
54
00
MIN
2400 MIN 2400 MIN
+/-
50
80
0
C L
DEDICATED SPACE
SYMBOL HEIGHT
(800 - 1000mm)
50
0 T
O6
00
MA
X1
20
0
MAX1200
SHARED ZONE
(TYPICAL)
BOLLARD
EQ EQ
DIMENSIONS IN MILLIMETRES
EXAMPLE OF PARKING SPACE AND SHARED ZONE ONLY
ENTRY SIDE
CARPARKING REQUIREMENTS
PROPOSED CARPARKS AS INDICATED 50
WINE STORE
5.5
BGWA OFFICES, AMENITIES, KITCHEN & GENERAL STORAGE
@1.33 per 100m2415.6m²
8.5213.1m²BASED ON SHOP REQUIREMENTS
BASED ON LIGHT INDUSTRY REQUIREMENTS
THE GRAND HALL + FOYER
31.6315.8m²
CARPARKING REQUIRED 6
CARPARKING REQUIRED 32
CARPARKING REQUIRED 9
TOTAL CARPARKS REQUIRED 47
ACCESS CARPARKING NOTESSPACE IDENTIFICATIONEACH DEDICATED SPACE SHALL BE IDENTIFIED BY MEANS OF A WHITE
SYMBOL OF ACCESS IN ACCORDANCE WITH AS 2890.6 'OFF STREET PARKING FOR PEOPLE WITH DISABILITIES' BETWEEN 800mm AND 1000mm HIGH PLACED ON A BLUE RECTANGLE WITH NO SIDE MORE THAN
1200mm, PLACED AS A PAVEMENT MARKING IN THE CENTRE OF THE SPACE.
SPACE DELINEATIONDEDICATED PARKING SPACES SHALL BE OUTLINED WITH UNBROKEN LINES 80mm TO 100mm WIDE ON ALL SIDES EXCEPTING ANY SIDE DELINEATED
BY A KERB, BARRIER OR WALL.
SHARED AREAS SHALL BE MARKED AS FOLLOWS:
1. WALKWAYS WITHIN OR PARTLY WITHIN A SHARED AREA SHALL BE OUTLINED WITH UNBROKEN LONGITUDINAL LINES 80mm TO 100mm WIDE ON BOTH SIDES OF THE WALKWAY EXCEPTING ANY SIDE
DELINEATED BY A KERB, BARRIER OR WALL.2. OTHER VACANT NON-TRAFFICKED AREAS, WHICH MAY BE
INTENTIONALLY OR UN-INTENTIONALLY OBSTRUCTED (eg BY
UNINTENDED PARKING), SHALL BE OUTLINED WITH UNBROKEN LINES 80 TO 100 MM WIDE ON ALL SIDES EXCEPTING ANY SIDE DELINEATED BY A KERB, BARRIER OR WALL, AND MARKED WITH DIAGONAL STRIPES
150 TO 200 MM WIDE WITH SPACES 200 MM TO 300 MM BETWEEN STRIPES. THE STRIPES SHALL BE AT AN ANGLE OF 45 ±10 DEGREES TO THE SIDE OF THE SPACE.
GENERAL NOTES• NO SHARED AREA MARKINGS SHALL BE PLACED IN TRAFFICKED
AREAS.
• PAVEMENT MARKINGS SHALL BE YELLOW AND SHALL HAVE A SLIP RESISTANT SURFACE.
• RAISED PAVEMENT MARKERS SHALL NOT BE USED FOR SPACE
DELINEATION.• ENSURE ACCESS CARPARK AND SHARED ZONE COMPLIES WITH
LOCAL COUNCIL DEVELOPMENT GUIDELINES.
• PLEASE REFER SITE PLAN FOR SETOUT DETAILS
CARPARK NOTES• STANDARD CAR PARKING SPACES - 2.6m WIDE X 5.5m DEEP• ACCESSIBLE CAR PARKING SPACES - 2.6m WIDE X 5.5m DEEP WITH
SHARED ZONE 2.6m WIDE X 5.5m DEEP • PROVIDE CONCRET WHEEL STOP AT EACH PARKING SPACE
CARPARKING REQUIREMENTS
ACCESS CARPARKING REQUIREMENTS
@10 per 100m2BASED ON COMMUNITY CENTRE
@4 per 100m2
PROPOSED ACCESSIBLE CARPARKS 2
SITE SETOUT + BOUNDARY IDENTIFICATION:SET-OFF DIMENSIONS SHALL BE FROM THE ALLOTMENT BOUNDARIES AND NOT NECESSARILY THE FENCE LINES. BOUNDARY + EASEMENT LINES
ARE TO BE IDENTIFIED BY THE BUILDER ONSITE PRIOR TO CONSTRUCTION.
SITE WORKS NOTES:THERE ARE NO SIGNIFICANT TREES, SHRUBS OR EXISTING STRUCTURES (OTHER THAN THOSE INDICATED) ON THIS OR ADJOINING SITES OR PUBLIC PLACES THAT WILL AFFECT OR BE AFFECTED BY THE PROPOSED
BUILDING WORKS.
GENERAL LANDSCAPING:PROVIDE PERIMETER PROTECTION AROUND BUILDING TO AN APPROVED METHOD AS SCHEDULED IN THE ENGINEERS FOOTING CONSTRUCTION REPORT. (TYPICALLY 1000MM WIDE PERIMETER PAVING TO ENGINEERS DETAILS)
GENERALLY LANDSCAPE LAYOUT (PLANT SPECIES) SHALL BE AS INDICATED ON DRAWING OR, DETAILS OF PLANTING + PLANT SPECIES
TO BE PROVIDED TO COUNCIL SATISFACTION PRIOR TO COMMENCEMENT ON SITE.
STORMWATER MANAGEMENT:TO BE DIRECTED AWAY FROM BUILDING BY FALLS IN PAVING AND SURROUNDING GARDEN LEVELS.
THE METHOD OF STORMWATER DISPOSAL MUST NOT RESULT IN THE ENTRY OF WATER INTO ANY BUILDING OR ON TO THE LAND OF ANY ADJOINING OWNER.
ROOF WATER COLLECTION:ROOF WATER FROM A MINIMUM OF 50M2 OF THE ROOF CATCHMENT AREA OF THE BUILDING TO BE DIRECTED TO A RAINWATER TANK (MIN
1000 LITRE CAPACITY) VIA 100MMDIAM PVC STORMWATER PIPES. OVERFLOW TO BE DIRECTED MINIMUM 10M AWAY FROM TANK TOWARDS NEARBY GARDEN AREAS. INLET + OVERFLOW OF RAINWATER
TANK(S) TO BE FITTED WITH MOSQUITO PROOF, NON-DEGRADABLE SCREENS. RAINWATER TO BE PLUMBED TO THE FOLLOWING FIXTURES:(WHERE APPLICABLE) WC, WATER HEATER, ALL LAUNDRY COLD
WATER OUTLETS.
RAIN WATER TANKS:TO LOCATIONS AS SCHEDULED ON SITE PLAN: CAPACITY ?,
DIMENSIONS ?, COLOUR ?REFER TO BUSHFIRE NOTES FOR DEDICATED BUSHFIRE TANK REQUIREMENTS.
EXTERNAL LIGHTS:EXTERNAL LIGHTING IS TO BE ORIENTATED IN A DOWNWARDS DIRECTION TO MINIMIZE LIGHT SPILL ON TO NEIGHBOURING SITES
NEW CROSSOVERS:NEW CROSSOVERS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH LOCAL COUNCILS SPECIFICATIONS AND
GUIDELINES. REFER CONSULTING ENGINEERS DETAILS FOR PAVEMENT DESIGN.
TERMITE TREATMENT:PROVIDE 'TERMI-MESH' STAINLESS STEEL MESH OR 'HOMEGUARD' BIFLEX BARRIER SYSTEM, TO PERIMETER OF NEW BUILDING SLABS/ STRIP FOOTINGS+ UNDER TIMBER FRAMED ELEMENTS+ BRICK PIERS + TO ALL
SLAB PENETRATIONS. THE SLAB TO ACT AS PHYSICAL BARRIER TO REMAINDER OF BUILDING.
PROVIDE CHEMICAL SOIL BARRIER BY 'BIFENTHRIN' OR 'TERMICURE' INSECTICIDE SPRAY TO PERIMETER OF FOOTING + UNDER DECK AREAS.
BUILDER + OWNER ARE TO ENSURE A PERIODIC VISUAL INSPECTION FOR TERMITES BY MAINTAINING A MINIMUM 75MM FOOTING EDGE EXPOSURE + 25MM CLEARANCE TO ALL OBJECTS ADJACENT SLAB EDGE
(UNLESS OTHERWISE SPECIFIED BY LEVELS). ALL TERMITE SYSTEMS TO BE INSTALLED BY ACCREDITED CONTRACTOR.TERMITE SYSTEMS + FITTED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND AS.3660.1.
GENERAL NOTE:THIS PLAN MAY HAVE BEEN PREPARED FROM A COMBINATION OF FIELD
SURVEY AND EXISTING RECORDS FOR THE PURPOSE OF SHOWING EXISTING SITE CONDITIONS AND SHOULD NOT BE USED FOR ANY OTHER PURPOSE.
DRAWINGS SHOULD BE READ IN CONJUNCTION WITH LATEST COPIES OF THE 'CERTIFICATES OF TITLE' FOR ANY ADDITIONAL ENCUMBRANCES OR EASEMENTS LOCATED ON THE PROPERTY.
SITE NOTES
SITE AREA COVERAGE m²
SITE 30,642
WINE STORE 415.6
TOTAL BUILDING AREA 1,076.2 m²
VERANDAH 46.0
BGWA OFFICES 105.4
AMENITIES, KITCHEN & GENERAL STORAGE 107.7
PERGOLIA 36.5
THE GRAND HALL + FOYER 315.8
PERGOLIA 49.2
Issue
NOTES
Issued For By Chkd Date
This drawing is copyright and the property of JBG Architects Pty. Ltd. and must not be used without written authorisation. Do not scale this
drawing. All dimensions shown on drawings are in millimetres unless otherwise noted and should be verified on site before commencing building works. These architectural drawings are to be read in
conjunction with the building specification and consultant drawings. Any discrepancies are to be referred to the project architect for clarification prior to work commencing.
ABN 31 852 116 195
© c
op
yrig
ht
JB
G A
rch
ite
cts
Pty
. Ltd
. A
ll rig
hts
re
serv
ed
Drawing Number Issue
Project Number
Project Address
Drawing Title
J B G ARCHITECTS PTY LTDresidential - commercial - winery - planning - architecture - interiors - landscape
38 MURRAY STREETTANUNDA 5352
Architect
Client
P. 08 8563 1155
NOT FOR CONSTRUCTION
AHRENS GROUPWilhelm RoadKingsford SA 5118P. 08 8521 0000 E. [email protected]
PTY LTD
CA002
1341
SITE PLAN
1015 STOCKWELL ROADVINE VALE, SOUTH AUSTRALIA 5352
1 : 500A201
SITE PLAN1
0 5m 15m 20m 25m
1:500 @ A1, 1:1000 @ A3
10m
A CLIENT REVIEW WS JG 05.10.16
B BUILDER REVIEW WS JG 10.10.16
C CLIENT REVIEW / PLANNING WS JG 25.10.16
820
920
920920
920 920920 920
920
920
1000
120012001200
920
920
920
920
920920
920920
1220
920
920 920
920 920
VAULTS
WINE STORE
BARONS WINESTORE/DISPATCH
GENERAL STORE
ROOM 2ROOM 1ROOM 3
GENERALSTOREKITCHEN
COMMS
BARONSSTORE
BGWAOFFICE 1
BGWA OFFICE
GENERALSTORE
OFFICE 4 OFFICE 3 OFFICE 2
GENERAL STORE
GENERAL STORE
FOYER
PERGOLA
VERANDA
SERVICESSERVICES
920
920920
920
920
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
1220
1000
450 DEEPS SHELVES
POST
POST
12201220
CO
L
CO
L
CO
L
CO
L
CO
L
CO
L
CO
L
THE GRAND HALL
PERGOLIA
820
820
820
Issue
NOTES
Issued For By Chkd Date
This drawing is copyright and the property of JBG Architects Pty. Ltd. and must not be used without written authorisation. Do not scale this
drawing. All dimensions shown on drawings are in millimetres unless otherwise noted and should be verified on site before commencing building works. These architectural drawings are to be read in
conjunction with the building specification and consultant drawings. Any discrepancies are to be referred to the project architect for clarification prior to work commencing.
ABN 31 852 116 195
© c
op
yrig
ht
JB
G A
rch
ite
cts
Pty
. Ltd
. A
ll rig
hts
re
serv
ed
Drawing Number Issue
Project Number
Project Address
Drawing Title
J B G ARCHITECTS PTY LTDresidential - commercial - winery - planning - architecture - interiors - landscape
38 MURRAY STREETTANUNDA 5352
Architect
Client
P. 08 8563 1155
NOT FOR CONSTRUCTION
AHRENS GROUPWilhelm RoadKingsford SA 5118P. 08 8521 0000 E. [email protected]
PTY LTD
CA101
1341
FLOOR PLAN -PRESENTATION
1015 STOCKWELL ROADVINE VALE, SOUTH AUSTRALIA 5352
A CLIENT REVIEW WS JG 05.10.16
B BUILDER REVIEW WS JG 10.10.16
C CLIENT REVIEW / PLANNING WS JG 25.10.16
1 : 100A201
FLOOR PLAN - PRESENTATION1
0 1.0m 3.0m 4.0m 5.0m
1:100 @ A1, 1:200 @ A3
2.0m
FLOOR PLAN - GROUND + 0
WINE STORE ROOF SLAB + 3600
HIGH LEVEL WINDOW SILL + 4200
TOP OF ROOF + 6020
OFFICE CEILING + 3000
FLOOR PLAN - GROUND + 0
WINE STORE ROOF SLAB + 3600
HIGH LEVEL WINDOW SILL + 4200
TOP OF ROOF + 6020
OFFICE CEILING + 3000
FLOOR PLAN - GROUND + 0
WINE STORE ROOF SLAB + 3600
HIGH LEVEL WINDOW SILL + 4200
TOP OF ROOF + 6020
OFFICE CEILING + 3000
ROOF + TRIMS: SHEET CLADDING:RF.1: ROOF CLADDING
• CUSTOM ORB WITH MATCHING FLASHINGS. FINISH: GALVANISED• SELECT APPROPRIATE ROOF SHEET PROFILE TO SUIT ROOF PITCH
SKYLIGHTS + ROOF WINDOWS:SKY.1: SKYLIGHTS• FRAME FINISH TO MATCH ROOF COLOUR• INSTALL ROOF WINDOWS AT MINIMUM REQUIRED ROOF PITCH TO
MANUFACTURERS SPECIFICATIONS
FASCIAS + BARGE BOARDS:• PAINTED FASCIA; TBC
GUTTERS:RG: ROOF GUTTER• 200 HALF ROUND GUTTERS• GUTTER FINISH; GALVANISED• GUTTERS TO ACHIEVE A MINIMUM 1:200 FALL TOWARDS DOWNPIPES.• HALF ROUND A4 BRACKETS
DOWNPIPES/RAINHEAD:DP: DOWNPIPE
• 100dia DOWNPIPES WITH WALL BRACKETS AT 2000 C/C MAX.• DOWNPIPES AS INDICATED ON DRAWING- TO BE SPACED MAXIMUM
12M APART. LOCATIONS HAVE BEEN DETERMINED BASED ON VISUAL APPEARANCE AND TO FACILITATE ROOF DRAINAGE- IF FURTHER
DOWNPIPES ARE REQUIRED CONSULT OWNER OR ARCHITECT FOR PRIOR APPROVAL.
• DOWNPIPE FINISH; GALVANISED
SOFFITS/ EAVES LINING :FC.1 FIBRE CEMENT SHEETS• FIBRE CEMENT SHEETS WITH JOINING STRIPS SETOUT EVENLY.
• PAINTED FINISH; OFF WHITE• REFER TO REFLECTED CEILING PLAN FOR FURTHER INFORMATION• PROVIDE EAVES TO WALL TRIMS AT JUNCTION AS REQUIRED
WALLS:FACE BRICK:FB.1: FACE BRICK
• FACE BRICK IN FINISH; OLD RED BRICK• MORTAR IN FINISH; tbc (TRADITIONAL)
METAL SHEET CLADDING:
SM.1: SHEET METAL CLADDING• CUSTOM ORB SHEET CLADDING ; FINISH; GALVANISED• 50MM BOXED FLASHINGS AT ALL CORNERS AND OPENINGS• SHEETING IN ORIENTATION AS INDICATED ON DRAWING.
RENDER FINISH:RD.1: RENDER FINISH
• RENDER/ TEXTURE COAT FINISH TO WALLS. FINISH; 'DARK SOIL COLOUR' (SIMILAR TO COLORBOND LOFT), TBC
STONE WALLS:
ST.1: STONE WALLS
• NATURAL LOCAL STONE SOURCED (AS SCHEDULED ON FLOORPLANS)• 'DRY STACK' WITH DEEP RECESSED MORTAR (SIMILAR TO ST HUGO)• CONFIRM STONE PATTEN + MORTAR COLOUR WITH ARCHITECT
PRIOR TO INSTALLATION
EXPOSED TIMBER / HARDWOOD:• EXPOSED HARDWOOD SPECIES TO BE SEASONED: TBC
• PROVIDE CLEAR NATURAL OIL TO EXPOSED HARDWOODS
EXPOSED STEELWORK:• STEELWORK IN PAINTED FINISH; 'DARK SOIL COLOUR' (SIMILAR TO
COLORBOND LOFT), TBC
WINDOWS + DOORS:ALUMINIUM FRAMES:• ALUMINIUM FRAME IN POWDERCOAT FINISH; 'DARK SOIL COLOUR'
(SIMILAR TO COLORBOND LOFT), TBC
GENERAL NOTES:SELECT APPROPRIATE MATERIALS IN CONJUNCTION WITH THE REQUIREMENTS FOR APPLICABLE BUSHFIRE RISK AREA + FIRE RESISTANT MATERIALS NEAR BOUNDARIES.
THE BUILDER IS TO PROVIDE A SAMPLE OF EXTERNAL MATERIAL COLOURS + FINISHES TO THE OWNER PRIOR TO ORDERING.
EXTERNAL FINISHES SCHEDULE
Issue
NOTES
Issued For By Chkd Date
This drawing is copyright and the property of JBG Architects Pty. Ltd. and must not be used without written authorisation. Do not scale this
drawing. All dimensions shown on drawings are in millimetres unless otherwise noted and should be verified on site before commencing building works. These architectural drawings are to be read in
conjunction with the building specification and consultant drawings. Any discrepancies are to be referred to the project architect for clarification prior to work commencing.
ABN 31 852 116 195
© c
op
yrig
ht
JB
G A
rch
ite
cts
Pty
. Ltd
. A
ll rig
hts
re
serv
ed
Drawing Number Issue
Project Number
Project Address
Drawing Title
J B G ARCHITECTS PTY LTDresidential - commercial - winery - planning - architecture - interiors - landscape
38 MURRAY STREETTANUNDA 5352
Architect
Client
P. 08 8563 1155
NOT FOR CONSTRUCTION
AHRENS GROUPWilhelm RoadKingsford SA 5118P. 08 8521 0000 E. [email protected]
PTY LTD
CA201
1341
ELEVATIONS -PRESENTATION
1015 STOCKWELL ROADVINE VALE, SOUTH AUSTRALIA 5352
A CLIENT REVIEW WS JG 05.10.16
B BUILDER REVIEW WS JG 10.10.16
C CLIENT REVIEW / PLANNING WS JG 25.10.16
1 : 100
PRESENTATION - WEST ELEVATION1
1 : 100
PRESENTATION - NORTH ELEVATION2
1 : 100
PRESENTATION - SOUTH ELEVATION3
0 1.0m 3.0m 4.0m 5.0m
1:100 @ A1, 1:200 @ A3
2.0m
0 1.0m 3.0m 4.0m 5.0m
1:100 @ A1, 1:200 @ A3
2.0m
0 1.0m 3.0m 4.0m 5.0m
1:100 @ A1, 1:200 @ A3
2.0m
MARQUE LAWN
28200 15300
PROPOSED DEVELOPMENT
23900 10000
186000
S T
O C
K W
E L
L R
O A
D
SIT
E B
OU
ND
AR
Y
SIT
E B
OU
ND
AR
Y
ENTRY STONE WALLS
9500
FLOOR PLAN - GROUND + 0
WINE STORE ROOF SLAB + 3600
HIGH LEVEL WINDOW SILL + 4200
TOP OF ROOF + 6020
OFFICE CEILING + 3000
© c
op
yrig
ht
JBG
Arc
hit
ec
ts P
ty. Lt
d.
All
rig
hts
re
serv
ed
Drawing Number Issue
Project Number
Issue
NOTES
Issued For By Chkd Date
Project Address
Drawing Title
This drawing is copyright and the property of JBG Architects Pty. Ltd. and
must not be used without written authorisation. Do not scale this drawing. All
dimensions shown on drawings are in millimetres unless otherwise noted and
should be verified on site before commencing building works. These
architectural drawings are to be read in conjunction with the building
specification and consultant drawings. Any discrepancies are to be referred
to the project architect for clarification prior to work commencing.
ABN 31 852 116 195
J B G ARCHITECTSPTY LTDresidential - commercial - winery - planning - architecture - interiors -
landscape
38 MURRAY STREETTANUNDA 5352
Architect
Client
P. 08 8563 1155
NOT FOR CONSTRUCTION
AHRENS GROUPWilhelm RoadKingsford SA 5118P. 08 8521 0000 E. [email protected]
PTY LTD
AA301
1341
SECTIONS -PRESENTATION
1015 STOCKWELL ROADVINE VALE, SOUTH AUSTRALIA 5352
A CLIENT REVIEW / PLANNING WS JG 25.10.16
1 : 250A002
SITE SECTION1
1 : 50A102
PRESENTATION SECTION2
0 0.5m 1.5m 2.0m 2.5m
1:50 @ A1, 1:100 @ A3
1.0m
0 0.5m 1.5m 2.0m 2.5m
1:50 @ A1, 1:100 @ A3
1.0m