Tentative Interim Amendment NFPA ® Standard for the Installation of Stationary Pumps for Fire Protection 20 2010 Edition Reference: 11.4.1.2.4, A.11.4.1.2.1, and A.11.4.3 TIA 10-2 (SC 11-10-1/TIA Log #1035) Pursuant to Section 5 of the NFPA Regulations Governing Committee Projects, the National Fire Protection Association has issued the following Tentative Interim Amendment to NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection, 2010 edition. The TIA was processed by the Technical Committee on Fire Pumps, and was issued by the Standards Council on October 19, 2011, with an effective date of November 8, 2011. A Tentative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a proposal of the proponent for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making process. 1. In 11.4.1.2.4, insert “double wall or the tank shall be” so that the section reads as follows: 11.4.1.2.4 Fuel tanks shall be double wall or the tank shall be enclosed with a wall, curb, or dike sufficient to hold the entire capacity of the tank. 2. Delete annex note A.11.4.1.2.1. 3. Delete the last three paragraphs of A.11.4.3. Issue Date: October 19, 2011 Effective Date: November 8, 2011 (Note: For further information on NFPA Codes and Standards, please see www.nfpa.org/codelist) Copyright © 2011 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION

Upload: a4tech1

Post on 24-Nov-2015

527 views

Category:

Documents


5 download

TRANSCRIPT

  • Tentative Interim Amendment

    NFPAStandard for the Installation of Stationary Pumps for Fire Protection

    20

    2010 Edition Reference: 11.4.1.2.4, A.11.4.1.2.1, and A.11.4.3 TIA 10-2 (SC 11-10-1/TIA Log #1035) Pursuant to Section 5 of the NFPA Regulations Governing Committee Projects, the National Fire Protection Association has issued the following Tentative Interim Amendment to NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection, 2010 edition. The TIA was processed by the Technical Committee on Fire Pumps, and was issued by the Standards Council on October 19, 2011, with an effective date of November 8, 2011. A Tentative Interim Amendment is tentative because it has not been processed through the entire standards-making procedures. It is interim because it is effective only between editions of the standard. A TIA automatically becomes a proposal of the proponent for the next edition of the standard; as such, it then is subject to all of the procedures of the standards-making process. 1. In 11.4.1.2.4, insert double wall or the tank shall be so that the section reads as follows: 11.4.1.2.4 Fuel tanks shall be double wall or the tank shall be enclosed with a wall, curb, or dike sufficient to hold the entire capacity of the tank. 2. Delete annex note A.11.4.1.2.1. 3. Delete the last three paragraphs of A.11.4.3.

    Issue Date: October 19, 2011 Effective Date: November 8, 2011

    (Note: For further information on NFPA Codes and Standards, please see www.nfpa.org/codelist)

    Copyright 2011 All Rights Reserved NATIONAL FIRE PROTECTION ASSOCIATION