Block-type remote modules are now released! Add and combine as you like! Flexible system configuration is possible! Point 1 Point 1 Block-type configuration for compact installation! Block-type configuration for compact installation! Point 2 Point 2 Flexible combination with extension I/O module Flexible combination with extension I/O module Ready for flexible expansion of digital I/O points! Expandable up to 32 digital I/O points to remote I/O module. A digital extension I/O module can be connected to an analog input/output module! Setup is easy using the GX Works2 settings for overview and an accurate setting range. Point 3 Point 3 Easy set up for various functions! Easy set up for various functions! Remote I/O module DC input type NZ2GF2B1-16D Transistor output type NZ2GF2B1-16T (Sink type) NZ2GF2B1-16TE (Source type) Analog converter module Analog input type NZ2GF2B-60AD4 Analog output type NZ2GF2B-60DA4 Extension I/O module DC input type NZ2EX2B1-16D Transistor output type NZ2EX2B1-16T (Sink type) NZ2EX2B1-16TE (Source type) NEW NEW NEW New Product Release No.335E [December 2012] CC-Link IE Field Network Product Fast Logic Function (with Remote I/O module) Fast Logic Function (with Remote I/O module) Add an extension I/O module for high-speed I/O control! Add an extension I/O module for high-speed I/O control! Trigger Conversion Function (with analog input module) Trigger Conversion Function (with analog input module) Carry out collected data sampling as you please! Carry out collected data sampling as you please!

Upload: hoangthien

Post on 23-Apr-2018

217 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

Block-type remote modules are now released!Add and combine as you like! Flexible system configuration is possible!

Point 1 Point 1 Block-type

configuration for compact installation!

Block-type configuration for

compact installation! Point 2 Point 2 Flexible combination with

extension I/O moduleFlexible combination with

extension I/O moduleReady for flexible expansion of digital I/O points!

Expandable up to 32 digital I/O points to remote I/O module.A digital extension I/O module can be connected to

an analog input/output module!

Setup is easy using the GX Works2settings for overview andan accurate setting range.

Point 3 Point 3 Easy set up for

various functions!Easy set up for

various functions!

Remote I/O moduleDC input type NZ2GF2B1-16DTransistor output type NZ2GF2B1-16T

(Sink type)

NZ2GF2B1-16TE(Source type)

Analog converter moduleAnalog input type NZ2GF2B-60AD4Analog output type NZ2GF2B-60DA4

Extension I/O moduleDC input type NZ2EX2B1-16DTransistor output type NZ2EX2B1-16T

(Sink type)

NZ2EX2B1-16TE(Source type)

NEW

NEWNEW

New Product Release No.335E [December 2012]

CC-Link IE Field Network Product

Fast Logic Function(with Remote I/O module)

Fast Logic Function(with Remote I/O module)

Add an extension I/O module for high-speed I/O control!

Add an extension I/O module for high-speed I/O control!

Trigger Conversion Function(with analog input module)

Trigger Conversion Function(with analog input module)

Carry out collected datasampling as you please!Carry out collected datasampling as you please!

Page 2: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

1

Block-type module for a compact system configuration!Simple distribution of I/O devices according to the installation environment

Direct connection of remote I/O modules and analog input/output modules can be freely established with CC-Link IE Field Network. Add and combine as you like! Customize the distribution arrangement of I/O devices of your equipment.

Vision sensor

PC

Analyzer

Signal light

Analog input module

Ethernet adapter module

PC

PLC(Intelligent device station)GOT

(Graphic Operation Terminal)

Industrial switching HUB

Industrial switching HUB

NEW

Remote I/Omodule

NEWRemote I/O module

NEW

Extension I/Omodule

NEW

Analog output module

NEW

Extension I/O module

NEW

PLC(Master station)

PLC(Local station)

Wireless LANadapter

Pressure transmitter Current loop converter

Signal converterDistributorDisplacement sensorProximity sensor

Positioner Pressure control valve

Add as you like!Power and communication cables not required!

Freely add I/O points to a remoteI/O module or analog input/output module.

Push button switch

Selector switch Limit switch

Photoelectricsensor

Signal light

Servo amplifier

Inverter

Gigabit Ethernet Field Network with high flexibility enables intelligent manufacturing systems to perform high speed I/O control and distributed control simultaneously. Please refer to "Ethernet-based Open Network CC-Link IE Product Catalog" to get the details. Ethernet-based Open Network

CC-Link IE Product Catalog

CWS

JUXTA

PLC(Local station)

Electromagneticcontactor

Page 3: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

2

Easy installation and setup according to your application useCompact block type model for convenient and versatile installation!

Easy installation and setup. You can remove the terminal block with the I/O cables connected, for flexible rearrangement of your equipment.

Y0 1 2 3 Y4 5 6 7 Y8 9 A B YC D I/OPWE F

12 4

46

11 5

510 69 8

0 01192

283

377

TEST

NZ2GF2B1-16T

RUNPW MODE ERR.

X10 X1 STATION NO.

D LINK

+24V

24G

1 3

2 4

5 7

6 8

9 11

10 12

13 15 17

1814 16

Two-piece terminal block can remove easily.Removing and replacing module without re-wiring is possible.

Connect an Ethernet cable.

q Installation methods

Module can be installed in six directions.Compact block type module meets various installation methods.

Connect the power supply cable.Easy connection with two-piece terminal block.

Horizontal(normal) Horizontal(reverse)

Vertical

Vertical(upside down)Downward Upward

t Ethernet cable wiring

e External I/O connection

r Power supply connection

Set the station number (from 1 to 120) with the rotary switch. The rotary switch easily helps thesetting.

w Station number setting

Y0 1 2 3 Y4 5 6 7 Y8 9 A B YC D

12 4

46

11 5

510 69 8

0 01192

283

377

TEST

NZ2GF2B1-16T

RUNPW MODE ERR.

X10 X1 STATION NO.

D LINK

+24V

24G

1 3

2 4

5 7

6 8

9 11

10 12

13

14

L ER

LINK12 4

4611 5

510 69 8

0 01 192283

377

TEST

1 3

2 4

5 7

6 8

P1

L ER

LINK

P2

NZ2GF2B1-16T

(FG)

+24V

24G

RUNPW MODE ERR.

X10 X1 STATION NO.

D LINK Y0 1 2 3 Y4 5 6 7

Point 1

Easy five steps to the installation

Function at the extension module installationCombine as you like for a flexible system configuration

An I/O extension module can be connected to a remote I/O module or analog input/output module, expanding your I/O points. You can add digital I/O points to a remote I/O module or an analog module.

Extension I/O module(Digital I/O)

Remote I/O moduleAnalog input/output module

+Remote input module

Remote output module

Analog input module

Analog output module

Extension input module

Extension output moduleRemote I/O moduleAnalog input/output

module

Extension I/Omodule+

Expansion with an analog input/output module is also possible.Power and communication cables not required!

Just connect an I/O extension module to the right side of the remote I/O module or analog input/output

module. Expand the I/O points according toyour use application!

Point 2

Page 4: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

3

Easy setup for various functions!Easy to use engineering software GX Works2 for the functions settings

Intuitive operation can automatically registers remote I/O modules and analog modules. Just select a module from the module list. Configuration of the system is easy, reducing program designing costs. Setup is easy using GX Works2 for the parameter settings of the various functions.

Analog input module

CC-Link IE Field Networkmaster/local module*1

System configuration example

GX Works2*2 setting example

Module configuration Module list

*2) The setting and diagnosis for remote I/O module, analog conversion module or extension I/O module requires GX Works2 Version.1.91V or later.

Analog output module Remote input module

Remoteoutput module

Extensioninput module

Add the module by

drag-and-drop.

■ CC-Link IE configuration

■ Module parameter settings

Description included for

easy understanding

Since the settings rangeis clearly known, setup

without confusion is possible

Easy settings selection

using the pull-down list

*1) Remote I/O module, analog conversion module or extension I/O module requires the following module.・CC-Link IE Field Network master/local module (QJ71GF11-T2 or LJ71GF11-T2) whose first 5-digit serial number is 14102 or later.

Setup is easy usingGX Works2 for the

parameter settings of the various functions.

Just drag and drop the expansion module over theremote I/O module or the analog input/output

module. Easy module registration without the module name text entry.

The station type, RX/RY and RWr/RWw setting pointsare automatically specified.

Point 3

Page 5: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

4

Fast Logic Function (with remote I/O module)Combine an extension module for high-speed I/O control!

Trigger Conversion Function (with analog input module)Precise A/D conversion control not affected by sequence or link scan

Remote I/O module with the expansion module controls I/Os according to the predefined conditionswithout the CPU module processing or the network communication, making possible high-speed I/O control.Two inputs can be output using the AND or OR logic(output condition).

By turning on the trigger conversion request directly from the I/O expansion module, the analog-digital (A/D) conversion can be carried out without any programing. The values obtained from A/D calculations are not affected by the sequence scan time or the link scan time, enabling precise control. Setup is easy using the GX Works2 parameter setting.

Sends the inputs signals

Receives theoutput signal

Selector switch Photoelectronicsensor

Selector switch Photoelectronic sensor

Photoelectronic sensor

Coating applicator

Photoelectronic sensor

Coating applicator

Output signal Output signal

Input signals

With the fast logic functionWithout the fast logic function

CPU module processesthe data

(with sequence program)

*3) When the "OR" logic is used, either of the input signal can be turned on and the output signal is output.

When the two input signals are turned on by

the "AND" logic, the output signal is output.*3

Fast response according to

the predefined conditions!

Analog input moduleExtensioninput module

Displacementsensor

Photoelectric sensor

q Trigger conversion request signal

Forwardw Analog inputsignal

■ Trigger Conversion Function setting example [1]Set "Triggerconversion mode"

[2]Specify the inputused as a trigger.

Setup complete!

Page 6: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

5

Product lineup

l16 points output, 12 to 24VDC, 0.5A/point, 4A/common, transistor output (sink type, source type) 1-wire, terminal block type

lThe output ON count accumulation function accumulates the ON/OFF count of the relays, etc. connected to the output module. Refer to the accumulated count to determine when to replace the connected device. You can use this value for preventive maintenance.

lConnect an I/O extension module (input type) and use the fast logic function.

CC-Link IE Field Network remote I/O module

[Output module]

NZ2GF2B1-16T/-16TE

l16 points input, 24VDC (positive/negative common shared) 1-wire, terminal block typelUse the high-speed response and the input response time setting function to select the input

response speed. Minimum response time can be set at 0 ms. You can also specify a larger response time value if you like.

lConnect an I/O extension module (output type) and use the fast logic function.

[Input module]

NZ2GF2B1-16D Remote device sta.DC input

Remote device sta.Transistor output

l16 points output, 12 to 24VDC, 0.5A/point, 4A/common, transistor output (sink type, source type) 1-wire, terminal block type

l16 output points can be added to a remote I/O module or analog module. Use the fast logic function with an I/O extension module to your remote I/O input module for a faster

I/O response time.

CC-Link IE Field Network remote I/O module (extension module type)

l16 points input, 24VDC (positive/negative common shared) 1-wire, terminal block typelUp to 16 input points can be added to a remote I/O module or analog module.

Use the fast logic function with an I/O extension module to your remote I/O output module for a faster I/O response time.Sampling timing of the analog-digital conversion values can be more precisely controlled using the trigger conversion function with an I/O extension module to the analog input module.

[Extension input module]

NZ2EX2B1-16D

[Extension output module]

NZ2EX2B1-16T/-16TE

l4 channels voltage/current output, analog output typelConversion speed is 100 ms per channel.lThe scaling function is available to convert digital values into arbitrary scaling values without a

ladder program.

CC-Link IE Field Network analog converter module

[Digital-analog converter module]

NZ2GF2B-60DA4 Remote device sta.

l4 channels voltage/current input, analog input typelConversion speed can be switched between the 400 ms per channel and 1 ms per channel.lThe scaling function is available to convert values obtained through digital calculations into

arbitrary scaling values without a ladder program.lConnect an I/O extension module (input type) and use the trigger conversion function. Sampling

timing of the analog-digital conversion values can be more precisely controlled.

[Analog-digital converter module]

NZ2GF2B-60AD4 Remote device sta.Analog input

Analog output

DC input

Transistor output

Page 7: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

6

Remote I/O module, extension I/O module (DC input type)Module name CC-Link IE Field Network remote I/O module CC-Link IE Field Network remote extension I/O module

Model NZ2GF2B1-16D NZ2EX2B1-16DNumber of input points 16 pointsInput type positive/negative common shared type

Input response time

OFF to ON 0ms*1/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms (Initial setting: 10ms)ON to OFF 0ms*1/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms (Initial setting: 10ms)

FunctionsError notification, Input OFF delay,

Input response time setting, Fast logic (with extension output module), CC-Link IE Field Network diagnostic, etc.

Error notification, Input OFF delay,Input response time setting, Fast logic (with output module),

CC-Link IE Field Network diagnostic, etc.

Module powersupply

Voltage 24VDC (ripple rate: 5% or less)(Allowable voltage range: 20.4 to 28.8VDC)

Current 180mA or less (24VDC, all points ON) 20mA or less (24VDC, all points ON)*2

External connections

Communication part RJ45 connector –Module power supply Terminal block for module power supply and FG –I/O part 18-point two-piece terminal block (M3 screw)

*1) If the input response time is set to "0ms", the actual input response time is 80μs at OFF → ON, and 140μs at ON → OFF.*2) The current for the extension I/O module is provided from the connected main module.

Analog converter module (analog input/output type)Module name

CC-Link IE Field Network remote analog-digital converter module

CC-Link IE Field Network remote digital-analog converter module

Model NZ2GF2B-60AD4 NZ2GF2B-60DA4

Number of analog input points 4 points (4 channels) –Number of analog output points – 4 points (4 channels)

Analog input Voltage: -10 to 10VDC (Input resistance 1MW)Current: 0 to 20mADC (Input resistance 250W) –

Analog output – Voltage: -10 to 10VDC (external load resistance value: 1kW to 1MW)Current: 0 to 20mADC (external load resistance value: 0W to 600W)

I/O characteristics, max. resolution

Voltage

Analog input Digital output Max. resolution Analog output Digital input Max. resolution

-10 to 10V-16000

to 16000

0.625mV -10 to 10V -16000 to 16000 0.625mVUser range setting 1 (-10 to 10V) 0.5mV 0 to 5V

0 to 120000.416mV

User range setting 2 (-5 to 5V) 0.25mV 1 to 5V 0.333mV0 to 5V

0 to 160000.3125mV User range setting 1 (-10 to 10V) -12000 to 12000 0.333mV

1 to 5V 0.25mV – – –

Current

0 to 20mA0 to 16000

1.25mA 0 to 20mA

0 to 12000

1.66mA4 to 20mA 1mA 4 to 20mA 1.33mA

User range setting 2 (-20mA to 20mA) -16000 to 16000 1mA User range setting 2 (0mA to 20mA) 0.95mA

Accuracy(Ambient temperature)

(25±5°C) – Within ±0.2%

(0 to 55°C) Within ±0.2% Within ±0.3%

Conversion speed 400ms/channel, 1ms/channel 100ms/channel

FunctionsOffset/gain setting, Scaling, Digital clipping function, Difference

conversion, Trigger conversion, Alert output function, Error notification, CC-Link IE Field Network diagnostic, etc.

Offset/gain setting, Scaling, Digital value range check,Alert output function, Error notification, CC-Link IE Field Network

diagnostic, etc.

External power supply 24VDC (20.4 to 28.8VDC)Current consumption: 230mA

24VDC (20.4 to 28.8VDC)Current consumption: 325mA

External connections

Communication part RJ45 connector

Module power supply Terminal block for module power supply and FG

I/O part 18-point two-piece terminal block (M3 screw)

Remote I/O module, extension I/O module (transistor output type)Module name CC-Link IE Field Network Remote I/O module CC-Link IE Field Network Remote extension I/O module

Model NZ2GF2B1-16T NZ2GF2B1-16TE NZ2EX2B1-16T NZ2EX2B1-16TE

Number of output points 16 points

Output type Sink type Source type Sink type Source type

Response time

OFF to ON 0.5ms or lessON to OFF 1.5ms or less (resistance load)

Functions

Error notification, Output HOLD/CLEAR setting, Cyclic data update monitoring, Number of ON times integration, External power supply

monitoring, Fast logic (with extension input module), CC-Link IE Field Network diagnostic, etc.

Error notification, Output HOLD/CLEAR setting, Cyclic data update monitoring, Number of ON times integration, External

power supply monitoring, Fast logic (with input module), CC-Link IE Field Network diagnostic, etc.

Module powersupply

Voltage 24VDC (ripple rate: 5% or less)(Allowable voltage range: 20.4 to 28.8VDC)

Current 190mA or less (24VDC, all points ON) 30mA or less (24VDC, all points ON)*3

External connections

Communication part RJ45 connector –Module power supply Terminal block for module power supply and FG –I/O part 18-point two-piece terminal block (M3 screw)

*3) The current for the extension I/O module is provided from the connected main module.

Main performance specifications

Page 8: NEW NEW NEW - Sirius Tradingsuport.siriustrading.ro/02.DocArh/03.NET/05.Module distribuite CC... · Easy installation and setup according to your application use ... calculations

External dimensions

Product list

NZ2GF2B1-16D/-16T/-16TE NZ2GF2B-60AD4/NZ2GF2B-60DA4

NZ2EX2B1-16D/16T/16TE

Product name Model Specifications

CC-Link IE Field Network remote I/O module

NZ2GF2B1-16D 16 points input, 24VDC (positive/negative common shared) 1-wire, terminal block type, response time 0-70ms

NZ2GF2B1-16T 16 points output, 12 to 24VDC, 0.5A/1 point, transistor output (sink type) 1-wire, terminal block type

NZ2GF2B1-16TE 16 points output, 12 to 24VDC, 0.5A/1 point, transistor output (source type) 1-wire, terminal block type

CC-Link IE Field Network analog-digital converter module

NZ2GF2B-60AD4 4 channels voltage/current analog-digital converter module (analog input type)

CC-Link IE Field Network digital-analog converter module

NZ2GF2B-60DA4 4 channels voltage/current digital-analog converter module (analog output type)

CC-Link IE Field Network remote I/O module(extension module type)

NZ2EX2B1-16D 16 points input, 24VDC (positive/negative common shared) 1-wire, terminal block type, response time 0-70ms

NZ2EX2B1-16T 16 points output, 12 to 24VDC, 0.5A/1 point, transistor output (sink type) 1-wire, terminal block type

NZ2EX2B1-16TE 16 points output, 12 to 24VDC, 0.5A/1 point, transistor output (source type) 1-wire, terminal block type

Note) NZ2GF2B1-16D is shown in the figure.NZ2GF2B1-16T/-16TE, NZ2GF2B-60AD4 or NZ2GF2B-60DA4 has the same size.

Note) NZ2EX2B1-16D is shown in the figure. NZ2EX2B1-16T/-16TE has the same size.

234

133

504.5

(74.5)68

DIN rail center

4 23

68

504.5

84.58.5

44

(74.5)

DIN rail center

HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANNAGOYA WORKS: 1-14, YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN

USA Mitsubishi Electric Automation lnc. Tel : +1-847-478-2100 500 Corporate Woods Parkway, Vernon Hills, IL 60061, USA Fax : +1-847-478-2253Brazil MELCO-TEC Representacao Comercial e Assessoria Tecnica Ltda. Tel : +55-11-4689-3000 Rua Jussara, 1750 - Bloco B- Sala 01 Fax : +55-11-4689-3016 Jardim Santa Cecília- CEP 06465-070, Barueri, São Paulo, BrazilGermany Mitsubishi Electric Europe B.V. German Branch Tel : +49-2102-486-0 Gothaer Strasse 8, D-40880 Ratingen, Germany Fax : +49-2102-486-1120UK Mitsubishi Electric Europe B.V. UK Branch Tel : +44-1707-28-8780 Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, UK. Fax : +44-1707-27-8695Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : +39-039-60531 Viale Colleoni 7-20864 Agrate Brianza (Milano), Italy Fax : +39-039-6053-312Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : +34-93-565-3131 Carretera de Rubi 76-80.AC.420, E-08190 Fax : +34-93-589-1579 Sant Cugat del Valles (Barcelona), Spain France Mitsubishi Electric Europe B.V. French Branch Tel : +33-1-5568-5568 25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : +33-1-5568-5757Czech Republic Mitsubishi Electric Europe B.V. Czech Branch Tel : +420-251-551-470 Avenir Business Park, Radicka 751/113e, 158 00 Praha5, Fax : +420-251-551-471 Czech Republic Poland Mitsubishi Electric Europe B.V. Polish Branch Tel : +48-12-630-47-00 32-083 Balice ul. Krakowska 50, Poland Fax : +48-12-630-47-01Russia Mitsubishi Electric Europe B.V. Russian Branch Tel : +7-812-633-3497 St.Petersburg office Fax : +7-812-633-3499 Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office 720; 195027, St. Petersburg, Russia

South Africa CBI-Electric. Tel : +27-11-977-0770 Private Bag 2016, ZA-1600 Isando, South Africa Fax : +27-11-977-0761China Mitsubishi Electric Automaiton (China) Ltd. Tel : +86-21-2322-3030 10F, Mitsubishi Electric Automation Center, Fax : +86-21-2322-3000 No.1386 Hongqiao Road, Changning District, Shanghai, ChinaTaiwan Setsuyo Enterprise Co., Ltd. Tel : +886-2-2299-2499 6F., No.105, Wugong 3rd Road, Wugu District, Fax : +886-2-2299-2509 New Taipei City 24889, Taiwan, R.O.C.Korea Mitsubishi Electric Automation Korea Co., Ltd. Tel : +82-2-3660-9530 3F, 1480-6, Gayang-Dong, Gangseo-Gu, Seoul, 157-200, Korea Fax : +82-2-3664-8372Singapore Mitsubishi Electric Asia Pte, Ltd. Industrial Division Tel : +65-6470-2308 307, Alexandra Road, Mitsubishi Electric Building, Fax : +65-6476-7439 Singapore, 159943Thailand Mitsubishi Electric Automation (Thailand) Co., Ltd. Tel : +66-2906-3238 Bang-Chan Industrial Estate No.111 Soi Serithai 54, Fax : +66-2906-3239 T.Kannayao, A.Kannayao, Bangkok 10230 ThailandIndonesia P.T. Autoteknindo Sumber Makmur Tel : +62-21-663-0833 Muara Karang Selatan, Block A/Utara No.1 Kav. Fax : +62-21-663-0832 No.11, Kawasan Industri Pergudangan, Jakarta-Utara 14440, P.O, Box 5045, Indonesia India Mitsubishi Electric India Pvt. Ltd. Tel : +91-20-2710-2000 Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune, 411026, Fax : +91-20-2710-2100 Maharastra State, IndiaAustralia Mitsubishi Electric Australia Pty.Ltd. Tel : +61-2-9684-7777 348 Victoria Road PO BOX11, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245

Country/Region Sales office Tel/Fax Country/Region Sales office Tel/Fax

1212 (MDOC) Specifications subject to change without notice.Printed in Japan on recycled paper.