New Age Enthalpy Transfer 1

Upload: kordell

Post on 06-Jan-2016

31 views

Category:

Documents


0 download

DESCRIPTION

New Age Enthalpy Transfer. Agenda Polymer Membrane Technology What is an Energy Recovery Ventilator How does it work Why should we use Examples New Age Technology AHRI Ratings. Nano - Polymer Technology Tampa Bay Area, Formed in 1999 Latest Nano-Polymer Technology - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: New Age Enthalpy Transfer

New Age Enthalpy Transfer

1

Page 2: New Age Enthalpy Transfer

Agenda• Polymer Membrane Technology• What is an Energy Recovery Ventilator

• How does it work• Why should we use

• Examples• New Age Technology• AHRI Ratings

2

Page 3: New Age Enthalpy Transfer

Nano - Polymer Technology

• Tampa Bay Area, Formed in 1999

• Latest Nano-Polymer Technology

• Multiple Production Facilities

• Proven New Patented Technology: “Next Generation” ERV

• Technology Developed From Fuel Cell R&D

• Future R&D Projects

•Desalination, Advanced Air Conditioning, Ultra capacitor3

Page 4: New Age Enthalpy Transfer

Nano - Polymer Technology• Fuel Cell – proton exchange membrane

4

Page 5: New Age Enthalpy Transfer

What is an Energy Recovery Ventilator• An ERV is an energy recovery exchanger

•Different from an HRV

• ERV Transfers temperature and humidity• Uses indoor air to “pre-condition” outside air• Required by code in many states• Saves capital and reduces operating costs

•Great ROI

5

Page 6: New Age Enthalpy Transfer

Types of ER / HR Ventilators• Fixed Plate Heat: sensible only, low cost / maintenance

•Plastic, aluminum

• Fixed Plate Energy: sensible / latent independently•Plastic, aluminum, cellulose fiber (paper), nano polymer membrane

• Enthalpy Wheel: good moisture transfer, higher maintenance, moving parts

6

Page 7: New Age Enthalpy Transfer

7

Why Energy Recovery ?• Improves Indoor Air Quality

• Reduces Co2, Formaldehydes, Allergens, etc.

• Healthier Indoor Environment

• Employees – increased productivity, reduced absence

• Students – better performance, increased attendance

• Reduces Humidity and Mold

• Reduced Energy Consumption

• Less work by hvac system

• Reduced tonnage, new construction

Page 8: New Age Enthalpy Transfer

New Age Enthalpy Transfer Technology

8

Page 9: New Age Enthalpy Transfer

So What’s Different ?

• Independent heat and moisture exchange in a fixed

plate• Zero flow field leakage (AHRI Certified)• Great moisture transfer with no moving parts• Moisture is transferred in a molecular state

• no liquid means no drain required• no mold / mildew• inherently anti-microbial

• Simple and low maintenance 9

Page 10: New Age Enthalpy Transfer

AHRI Effectiveness Ratings

10

EffectivenessWheel

500 cfm

Plate A 530 cfm

Plate B 750 cfm

New Age

500 cfm

Sensible (AHRI

Summer)

68% 54% 71% 71%

Latent (AHRI Summer) 60% 30% 48% 64%

Sensible (AHRI

Winter)

68% 58% 71% 71%

Latent (AHRI Winter) 60% 41% 35% 60%

Page 11: New Age Enthalpy Transfer

Old HRV / ERV Application Map

11

Page 12: New Age Enthalpy Transfer

New ERV Application Map

12

Page 13: New Age Enthalpy Transfer

Future R&D Projects for Membrane• Desalination

• currently testing

•Advanced Air Conditioning• R & D

• First Responders Clothing• similar to gore tex

• Super Capacitor

13

Page 14: New Age Enthalpy Transfer

NanoClear• Desalination – how it works

14

Warm salty water flow (warmed by re-using waste heat or capturing environmental heat) Up to 75%

capture

H2O molecules only diffuse through the membrane condensing on a thermal energy recovery surface

Membrane Prototype

Page 15: New Age Enthalpy Transfer

•Advanced Air Conditioning•prototype

15

Page 16: New Age Enthalpy Transfer

New Age Enthalpy TransferQuestions ?

16