B.Schillinger 1 Neutron Imaging at the neutron radiography and tomography facility ANTARES Burkhard Schillinger, Johannes Brunner, Elbio Calzada, Florian Grünauer, Hongyun Li, Klaus Lorenz, Martin Mühlbauer, Michael Schulz FRM-II and Physics E21, Technische Universität München, D-85748 Garching, Germany

Upload: dinhthien

Post on 04-Jun-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 1

Neutron Imagingat the neutron radiography and tomography

facility ANTARES

Burkhard Schillinger, Johannes Brunner, Elbio Calzada, Florian Grünauer,

Hongyun Li, Klaus Lorenz, Martin Mühlbauer, Michael Schulz

FRM-II and Physics E21, Technische Universität München, D-85748 Garching, Germany

Page 2: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 2

Introduction: Why we use neutron radiography

Using all kinds of different radiation

Small angle scattering in neutron radiography and tomography

Phase contrast imaging with neutrons

Stroboscopic imaging with neutrons

Page 3: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 3

Why we do neutron radiography: The mass attenuation coefficient of elements

Page 4: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 4

Actual attenuation for technical materials

Page 5: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 5

Introduction:Setup for neutron tomography rotation table, scintillator screen and CCD camera

Page 6: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 6

1. Collimator inside of the biological shielding

2. External vertical beam shutter

3. Pneumatic fast shutter

4. Flight tube

5. Flight tube shielding

6. Block house

7. Wall and beam stop

8. Sliding door

12345

6

7 8

AntaresAdvanced Neutron Tomography And Radiography Experimental System

Page 7: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 7

Introduction:

The sample manipulator can carry up to 500

kg samples up to 1 m diameter.

Cross section of the ANTARES facility at FRM-II.

From the reactor(on the right), the beam passes the shutter and collimator and the flight tube

towards the block house.

Page 8: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 8

External hydraulic shutter of the ANTARES facility.

The slider contains two different collimators that can be positioned and locked in place by a

position-controlled hydraulic system and hydraulic clamps.

Page 9: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 9

A pneumatic fast shutter at the beginning of the flight tube is used to shut off the thermal

beam between exposures in order to minimize activation of the sample.

The Shutter consists of a casing with B4C powder.

Page 10: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 10

A selector wheel with different masks for will allow to switch the facility to phase contrast

imaging within seconds.

It also contains a 2mm Cadmium plate to absorb the thermal and cold part of the spectrum and

to pass on only epithermal and fast neutrons.

Page 11: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 11

Oil remains

A standard neutron radiography: A diesel injector pump

Page 12: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 12

Huge contrast range: Loudspeaker with steel casing on cardboard box, plant seeds and grass, tape

Page 13: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 13

Computer hard disk (cutout of big image)

Page 14: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 14

A remote sensing thermometer..

Well visible: cable ties, insulation, plastic cogwheels.

Page 15: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 15

Huge contrast range: A gas pressure reducer with sealants and o-rings

Page 16: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 16

But on this oil-filled pump, thermal neutrons must fail….

Page 17: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 17

The epithermal picture, using the filter wheel with the Cd filter, shows better penetration….

Page 18: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 18

If we use the reactor as a gamma source, with the the fast neutron shutter closed and a gamma

scintillation screen, we can still find a lot of information! (We cleaned off the finger prints afterwards.)

Page 19: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 19

A removable 320 kV X-ray tube has been mounted before the flight tube.

This allows for alternate X-ray tomography in the identical beam geometry!

Extension: Planning accessories and more possibilities

Page 20: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 20

A removable 320 kV X-ray tube has been mounted before the flight tube.

This allows for alternate X-ray tomography in the identical beam geometry!

4. Extension: Planning accessories and more possibilities

Page 21: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 21

Comparison and combination of X-ray and neutron images

Photo of a printed circuit board.Note many parts with plastic or ceramic cases and lots of pins.

ImagesM. Schulz, TUM

Page 22: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 22

Comparison and combination of X-ray and neutron images

X-ray image.Most contrast is given by the metal pins.

Page 23: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 23

Comparison and combination of X-ray and neutron images

Neutron image.Most contrast is given by plastic parts, the metal pins are nearly transparent.

Page 24: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 24

Comparison and combination of X-ray and neutron images

Combination of both images.The X-ray image was subtracted from the neutron image.

Page 25: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 25

Comparison and combination of X-ray and neutron images

Photo of an unfinished ice hockey knee protector containg a chainmail mesh.

Page 26: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 26

Comparison and combination of X-ray and neutron images

The X-ray image shows dents and even some faults without revealing the causes.

Page 27: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 27

Comparison and combination of X-ray and neutron images

The Neutron image gives very gould contrast on the hydrogen of the foam material,but rather low contrast on the chain mail.

Page 28: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 28

Comparison and combination of X-ray and neutron images

The combination of both images reveals the shape of the rubber foam as well as the embedded chain mail.

Page 29: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 29

Comparison and combination of X-ray and neutron images

A toy plane combustion engine with a plastic propeller is another good example for the different properties of X-rays and neutrons.

Page 30: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 30

Comparison and combination of X-ray and neutron images

The X-rays easily penetrate the plastic propeller, still penetrate the Aluminium well,but are heavily attenuated by steel parts.

Page 31: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 31

Comparison and combination of X-ray and neutron images

Aluminium is very transparent for neutrons, steel is better penetrated than by X-rays, but plastic is very opaque..

Page 32: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 32

Neutron computed tomography

X-ray neutrons

Neutrons are not always better...

woodblock

...but in many cases, they are!

Page 33: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 33

First Tomographies at FRM-II.

Page 34: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 34

Segmentation of the data

First results

Page 35: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 35Radiography and tomography of a microwave klystron

Page 36: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 36

Radiography of a metal foam

Page 37: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 37

Radiography and tomography of a hollow spheres catalyst

Page 38: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 38

E. Calzada, H. LiTU München FRM-II / Physik E21

Small Angle Scattering

in Neutron Computed Tomography:

Detection of texture alteration in Al parts

using Neutron Computed Tomography

Detection of imprinted car chassis numbers

in smooth-polished metal sheets

B. Schillinger, M. Hofmann TU München FRM-II / Physik E21

A. Steuwer, R. GählerInstitut Laue-Langevin, Grenoble

L. EdwardsThe Open University , Milton Keynes

Page 39: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 39

The standard method:

Measurement of residual stress with neutron diffraction

d0

d

Residual stress

dd

*E∆

=σBragg‘s law

nλλλλ = 2d sinθθθθ

Page 40: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 40

- neutron flux- sample geometries- gauge volume- resolution

Optimised diffractometer

STRESS-SPEC at FRM-II

Page 41: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 41

Peak analysis

89 90 910

20

40

60 ∆d/d ~2x10-3

Fe(211) at λ = 1.6 ÅGe(511) & PSD

Inte

nsity

[a.u

.]

2θS [°]

• Gaussian peak profile• Peak shift simulated using Fe(211) reflection with Q-values:

5.3439 Å-1, 5.3492 Å-1 , 5.3545 Å-1

Page 42: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 42

Cold expanded fastener holes

• The primary source of aircraft fatigue is at joints.

• Cold expansion increases joint durability.

• Quantification of the benefits of cold expansion requires accurate reliable residual stress estimation.

Page 43: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 43Picture:http://www.fatiguetech.com/products/splitsleeve.html

The cold expansion process

• The most common method is FTI split sleeve expansion.

• At present, air worthiness authorities do not allow the benefitsof cold expansion to be included in design calculations.

Page 44: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 44

The Split Sleeve Cold Expansion Process

. Step 1 After verifying the starting hole size, slip the pre-lubricated split sleeve onto the mandrel, which is attached to the hydraulic puller unit.

. Step 2.Insert the mandrel and sleeve through the hole with the nosecap held firmly against the work piece

Step 3. Activate the puller unit. The mandrel is drawn through the sleeve and the hole. The combined thickness of the sleeve and the mandrel major diameter radially expand the hole. The lubricated sleeve reduces the pull force required, protects thehole, and allows the mandrel to exert radial forces through the entire thickness of the material.

Step 4. Remove and discard sleeve

Page 45: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 45

Measurement of Aluminium aircraft component by neutron computed tomography: (Idea by R. Gähler, ILL)

•Holes are drilled with less than the required diameter,

• then the holes are cold expanded with a thorn.

• At the edges, the Aluminium is compressed and deformed, the inner structure is altered.

•This is done to introduce compressive stress into the material to anticipate tensile stress from rivets in the hole.

• This leads to increased small angle scattering, showing more attenuation around the hole edge.

•The effect is NOT visible at ordinary holes.

Page 46: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 46

Test sample:

Aluminium sheet

Rolled out along the longitudinal direction

180 mm length, 40 mm width, 5 mm thickness

Initial hole drilled with diameter 9.52mm (3/8inch)

Cold expansion (4%) to 10 mm diameter

Page 47: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 47

-6000

-4000

-2000

0

2000

0 2 4 6 8 10

SynchrotronNeutronSachs

Distance from the bore of hole (mm)

Hoop

mic

rost

rain

Distance

Distance

Str

ain

Strain measurements with synchrotron radiation, neutrons, and simulated data

Page 48: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 48

Measurement of a 3D computed tomography of the test sample

• Distance sample to detector was approx. 50 cms.

• 400 projections recorded for calculation of the tomography

• The tomography delivers a range interval of gray values for the attenuation of Aluminium

• For visualisation of the 3D tomography, nearly the whole attenuation range for Aluminium is set

transparent, only the most attenuating part is set visible.

•The expanded area at the hole rim produces increased small angle scattering,

which in turn leads to increased attenuation of the transmitted beam.

The area clearly shows up in the computed tomography.

•Surprise: Even a wave structure resulting from the rolling of the Aluminium sheet is visible!

Page 49: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 49

Surprise: Even a wave structure resulting from the rolling of the Aluminium sheet is visible!

Ordinary holes with

phased edges

Widened

hole

compressed

Edges.

The

widening

was

asymmetric.

Piece

of tape

Pieces

of glue

Page 50: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 50

Second hole drilled for second tomography.

This was recorded with a smaller detector with less dynamics and sensitivity.

The distance to the detector was only 25 cms, but still, the difference is clearly visible!

Above:

Normal

full

view of

the

piece.

Page 51: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 51

These pictures show more clearly that they represent a true 3D tomography.

Page 52: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 52

E. Calzada, H. LiTU München FRM-II / Physik E21

Detection of imprinted car chassis numbers

in smooth-polished metal sheets

Page 53: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 53

The police brought us two smooth-polished metal sheets, where originally the car chassis

numbers had been imprinted.

Nothing is visible on the surface, but deep in the metal, the structure has been altered…

Page 54: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 54

The normal radiography shows nothing at all.

Page 55: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 55

But with a 7 mm pinhole, and 2 meters distance to the detector…

Page 56: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

T. Bücherl 56

Non-destructive Testing with Phase Contrast Imaging

K. Lorenz, E. Lehmann, E. Steichele, P. Vontobel

1. Introduction

2. Theory

3. Experimental Setups at PSI and FRM-II

4. Applications of the Phase Contrast Effect

5. Phase Retrieval

Page 57: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 57

Phase Contrast Radiography with

X-Rays and Synchrotron Light

X-ray image of a genetically engineered mouse (source: www.xrt.com.au):

Conventional radiography Phase contrast radiography

Page 58: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 58

Refraction of a wave by a mediumdetectorn

z

ϕλα ⊥∇∝∆

n= 1 - δ - iβ

phase shift absorption

Refractive index:

Angular deviation of the normal:

I

∆∆∆∆αααα

∇∇∇∇⊥⊥⊥⊥ϕϕϕϕ

Page 59: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 59

Fresnel diffraction

∫ Ω−=s

dszyxzyx ),,,(2

),;,( λδλ

πλϕ

Phase shift of a wave on its way s through a spherical object Ω, with a refractive

index n = 1 - δΩ :

Ω

xx

x

d2ϕ/d

2xdϕ/dxϕ

a) b) c)

Page 60: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 60

Requirements for Phase Contrast

1. Neutron beam with a high lateral spatial coherence length

2. The detector plane must be in the near field region

Schematic of a phase contrast radiography setup:

neutron sourcepinhole

object

detector

z

Page 61: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 61

Non-destructive testing of casted components

Page 62: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 62

Non-destructive testing of casted components

1 cm1 cm

conventional radiography phase contrast radiography

Page 63: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 63

Investigations on metal foams

Diameter of the pinhole: 0.5 mm

Distance pinhole-sample: 6.7 m

Distance sample-detector: 80 cm

Exposure time: 180 min

Detector: Imaging plates

1cm

Phase contrast radiography of an

aluminum foam, made at

NEUTRA

Page 64: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 64

Investigations on metal foams

1cm

An edge detection program can

determine the 2D-distribution of

the bubbles very quickly.

Each bubble in the foam creates a

closed line in the phase contrast

radiography.

This non-destructive testing

technique delivers quick

information about the

- average bubble size

- standard deviation from it

- homogeneity of the distribution

of the bubbles

Page 65: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 65

Investigations on metal foams

The ANTARES facility offers an even bigger field ov view…

Page 66: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 66

On a massive step wedge, we can even see the bright and dark part of the edge enhancement!

Page 67: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 67

Quantitative phase contrast

Material B

nB=1-δB-iβB

Material A

nA=1-δA-iβA

Neutronen

x

Detektor

xIn

tensität I

Phasen

schub ϕ

Page 68: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 68

Stroboscopic imaging

with neutrons

Page 69: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 69

What do we mean by “continuous fast imaging with neutrons“?

1) High-speed imaging of very fast, singular processes

requiring several thousand frames per second

Problems:

- the number of neutrons/photons in one time window

becomes very low and may be below the detector noise

- in classic detectors, the number of detector pixels that

can be read out in one time window

becomes very small, drastically decreasing resolution

Example: Gun shot...

....hardly feasible for neutrons!

But: New detectors are becoming fast enough (see below),

the neutron flux is the main limiting factor!

Page 70: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 70

What do we mean by “stroboscopic fast imaging with neutrons“?

2) Stroboscopic imaging of very fast but periodical processes

Advantage:

- the number of neutrons/photons in one time window

is still very low, but many exposures of the same time window of

the periodic process may be accumulated on the detector before read-out,

thus increasing the available intensity

Disadvantage:

- Only one time window of the periodic process can be recorded in

one sequence, the periodic process has to be recorded in a sequence

of many consecutive time window accumulations, sacrificing most

neutrons.

Example: Fuel injection / oil flux in a combustion engine

Page 71: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 71

Physical limitations

• Available neutron/photon flux in a time window

• Decay time of scintillation light

• readout speed of the detector

• gating time of the detector (if applicable)

Page 72: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 72

Decay time of typical ZnS+6LiF-Scintillator from datasheet:

µs

Decay to 10% in 80 µs

exposure times well below 100 µs seem to make no sense!

BUT: There is experimental evidence of better data... (see below)

Page 73: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 73

Working principle of a MCP image intensifier

Page 74: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 74

Measurements on a BMW engine

The beam NEUTROGRAPH at ILL Grenoble is the most intense neutron radiography

beam in the world,

with a flux of 3*109 n/cm2s and a collimation of L/D=140.

ILL, Universität Heidelberg, Paul-Scherrer-Institut and TU München collaborated on the

measurement of an electrically driven four-piston BMW engine.

The engine was driven by a 2kW electro motor, mounted on a vertical translation stage.

Since water cooling was not possible, the spark plugs were removed to reduce drag and

heat production.

The full cycle of this four-stroke engine running at 1000 rpm was split into

120 individual frames over 2 rotations,

Page 75: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 75

150 individual images were recorded as an

on-chip accumulation of a 200 microseconds

exposure each.

The total exposure time for the full run was

in the order of 18 minutes only.

The field of view was 24 cm * 24 cm.

The observation area could be varied by

displacement of the full set-up.

Measurements on a BMW engine

Page 76: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 76

First-time

visualisation of the

oil cooling of the

pistons!

Oil spreads on the piston

bottom

Oil jet ejected from below

onto the piston bottom

Valves

(two behind each other)

Page 77: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 77

Page 78: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 78

The ANTARES facility at FRM-II offers a lower flux (108 n/cm2s),

but higher collimation (L/D=400).

The time window was extended to 1 ms,

the rotation speed was reduced to 600 rpm,

which is well below the nominal idle speed of the engine.

The images show more motion unsharpness,

but better definition on the stationary parts.

At this rotation speed, the oil pump did not produce its nominal pressure,

the oil pressure was pulsed and produced blobs in the cooling oil jet.

Measurements at ANTARES, FRM-II

Page 79: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 79

Measurements at ANTARES, FRM-II

Static radiography

of the engine,

with horizontal

pressure tubes and

vertical backflow tubes

empty

Page 80: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 80

Measurements at ANTARES, FRM-II

Dynamic radiography

of the engine,

with oil filled

horizontal pressure

tubes and vertical

backflow tubes,

and an oil blob within

the oil jet to the piston

bottom

Page 81: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 81

Measurements at ANTARES, FRM-II

A static and a dynamic cutout beside each other.

The cylinders are not identical.

Backflow tubes are filled in the dynamic image,

the piston shows motion unsharpness.

Page 82: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 82

Blobs in jet

Oil curtains

detaching

Page 83: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 83

Oil curtains

detaching

Page 84: Neutron Imaging at the neutron radiography and tomography ... · at the neutron radiography and tomography facility ANTARES ... of cold expansion to be included in design calculations

B.Schillinger 84

Haben Sie nun eine Idee, wo Neutronen helfen können,Ihr Problem zu lösen?

Bitte gehen Sie auf

www.frm2.tum.deoder schreiben Sie

[email protected]

Für ein neues Problem ist eine Probeaufnahme kostenlos.