neutron detection for zero-knowledge protocol...superheated dro p ´ bubbl(µ detecto rs 8 bds1000...

14
NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL Francesco d Errico 1 , Alex Glaser 2 , Rob Goldston 2,3 , Sbastien Philippe 2 , Chiara Romei 1 1 Yale University, 2 Princeton University, 3 Princeton Plasma Physics Laboratory

Upload: others

Post on 18-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

NEUTRON DETECTION

FOR ZERO-KNOWLEDGE PROTOCOL

Francesco d’Errico1, Alex Glaser2, Rob Goldston2,3, Sebastien Philippe2, Chiara Romei1

1 Yale University, 2 Princeton University, 3 Princeton Plasma Physics Laboratory

Page 2: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

OUTLINE

2

• Zero-knowledge protocol for warhead verification

• Superheated emulsions (superheated drop “bubble”

detectors)

• Neutron activation imaging

Page 3: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

3

ZERO-KNOWLEDGE PROTOCOL (ZKP):ALICE CONVINCES BOB OF A CLAIM, WHILE

REVEALING NOTHING BEYOND THE TRUTH OF HER CLAIM

Key Elements: Interaction and Randomness

Glaser, Barak, Goldston, Nature, 510 (2014): 497–502

Page 4: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

ZKP WARHEAD VERIFICATION

Detector arrays to be preloaded by host with counts that

sum with neutron radiographic image to Nmax everywhere.

ZKP: Inspector selects which preload goes with which object!

4

Reference Object Test Object

14 MeV

neutron

source

Transmission

Detectors

Emission

Detectors

Page 5: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

ZKP WARHEAD VERIFICATION

• If the object and

the preload don’tmatch – you see it.

• More visible

with greater Nmax.

• For a match – even

the Poisson noise

carries no info.

5Glaser, Barak, Goldston, Nature, 510 (2014): 497–502

Page 6: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

DETECTOR REQUIREMENTS NON-ELECTRONIC DETECTION & STORAGE

TRANSMISSION

• Capable of storing 5,000 – 10’s of thousands of counts

- Preloads indistinguishable from measurement counts

• Sensitive only to 14 MeV neutrons- Energy threshold ~10 MeV, insensitive to γ’s

• 0.24% absolute detection efficiency gives 20,000 cts/hr

EMISSION (spontaneous and driven)

• Capable of storing thousands of counts- No imaging, so detectors may be ganged together

• Sensitive dominantly to fission neutrons- Energy threshold ~500 keV, insensitive to γ’s

(a 250 keV neutron source would eliminate all driven non-

fission sources of neutrons above 500 keV)

6

Page 7: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

SUPERHEATED EMULSIONS

• Fluorocarbon droplets in a steady superheated state.

• Vaporizations triggered by neutrons above selectable threshold energies.

• Can be totally insensitive to γs.7

Page 8: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

SUPERHEATED EMULSIONS

• Energy thresholds

depend on

composition & temp.

• Accurate

temperature control

required

• ~3% absolute

efficiency achievable

8d’Errico, NIM B, 184 (2001) 229-254

Page 9: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

SUPERHEATED EMULSIONS

• Emulsified fluids can be chosen to respond only to high-LET radiation.

• Bubbles remain trapped after formation and can be counted with a variety of techniques (e.g. , MRI, optical tomography, light scattering)

SUPERHEATED DROP “BUBBLE” DETECTORS

5

Photon discrimination

and neutron sensitivity tests

CT scan of detector

exposed to 1 Gy of

6 MV x-rays

CT scan of same

detector exposed to

2.5 mSv of AmBe

neutrons

1 Gy 6 MeV γ’s

Neutron recoils trigger “explosions” of metastable droplets.!Count large numbers of bubbles, e.g., by MRI.

2.5 mSv AmBe neutrons

6

9

Page 10: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

SUPERHEATED EMULSIONS

10

Photo

diodes

LEDs

Scattered light

• Instant read out

• Count rate insensitive

Page 11: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

SUPERHEATED EMULSIONS

Bubbles in commercial polymer-

based detectors expand

noticeably in 24 hours.

SUPERHEATED DROP “BUBBLE” DETECTORS

8

BDS1000

Figure 4. B2 immediately after irradiation (left), 24h later (right).

Bubbles in commercial polymer-based detectors expand noticeably in 24 hours.

1 Day

Readout after 1 day

Yale University

Figure 3. B2 immediately after irradiation (left), 24h later (right).

Bubbles in aqueous gel do not.

1 Day

SUPERHEATED DROP “BUBBLE” DETECTORS

8

BDS1000

Figure 4. B2 immediately after irradiation (left), 24h later (right).

Bubbles in commercial polymer-based detectors expand noticeably in 24 hours.

1 Day

Readout after 1 day

Yale University

Figure 3. B2 immediately after irradiation (left), 24h later (right).

Bubbles in aqueous gel do not.

1 Day

Bubbles in aqueous gel do not.

11

Page 12: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

NUCLEAR ACTIVATION IMAGING

Detector is an array of activation slugs

~ 3 cm long, 1.6 cm diameter

• Nb is an attractive mono-nuclidic option for transmission93Nb(n,2n)92mNb, Eth = 9 MeV, 10 d half-life

In for emission detectors

Count γ’s in bank of well detectors12

Page 13: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

NUCLEAR ACTIVATION IMAGING

Clean spectra and lo

w background may all

ow use of NaI detecto

rs.

13

Page 14: NEUTRON DETECTION FOR ZERO-KNOWLEDGE PROTOCOL...SUPERHEATED DRO P ´ BUBBL(µ DETECTO RS 8 BDS1000 Figure 4. B2 immediately after irradiation (left), 24h later (right). Bubbles in

CONCLUSIONS

Zero-knowledge protocol is a new approach based on differential radiography + differential emission

ZKP has unusual detector requirements

Key among them is reproducibility

Superheated emulsions hold promise, R&D must tackle

Temperature sensitivity

Read out optimization

Neutron activation imaging has different challenges

Potentially complex preloading

Maintenance of bank of γ detectors

We are open to innovations. Come talk with us.

14