mustang sampling product catalog

12
Analytically Accurate® Technology Preserve Sample Integrity Offset Joule-Thomson Cooling API 14.1 Compliancy ISO 8943, CSA, & CRN Approvals Class 1, Group D, Div 1 Location Enclosures Compact & Modular Systems Custom Engineering & Design Mustang Sampling ® Product Catalog Natural Gas | LNG | NGL | BIOGAS

Upload: danielle-bergum

Post on 25-Jul-2016

235 views

Category:

Documents


0 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Mustang Sampling Product Catalog

Analytically Accurate® Technology

Preserve Sample Integrity Offset Joule-Thomson Cooling API 14.1 Compliancy ISO 8943, CSA, & CRN Approvals Class 1, Group D, Div 1 Location

Enclosures Compact & Modular Systems Custom Engineering & Design

Mustang Sampling®

Product Catalog

Natural Gas | LNG | NGL | BIOGAS

Page 2: Mustang Sampling Product Catalog

Analytically Accurate® Technology

Maximum Heat Trace Tubing Lengths Per Circuit Breaker Sizes (in feet)

Ambient

Temperature

Start-Up

120 V 240 V

15 A 20 A 30 A 40 A 15 A 20 A 30 A 40 A

5 Watts

50ºF (10ºC) 230 270 270 270 460 540 540 540

0ºF (-18ºC) 140 190 270 270 285 380 540 540

-20ºF (-29ºC) 125 165 250 270 250 330 500 540

-40ºF (-40ºC) 110 145 220 270 220 295 440 540

50ºF (10ºC) 150 200 210 210 300 400 420 420 8 Watts

0ºF (-18ºC) 100 130 200 210 200 265 400 420

-20ºF (-29ºC) 85 115 175 210 175 235 350 420

-40ºF (-40ºC) 80 105 155 210 155 210 315 420

Our patented power connection design utilizes existing heat trace tubing powered without additional power or natural gas for proper operations and conforms to API 14.1. This Analytically Accurate® technology is a standard among many companies and utilized with multiple Mustang Sampling® products

Sample Conditioning & Control

Page 3: Mustang Sampling Product Catalog

Analytically Accurate® Technology

■ Utilizes existing heat trace tubing for power ■ Conforms to API 14.1 guidelines by removing sample at line conditions and maintaining heat 30

F above hydrocarbon dewpoint

■ Heated, insulated, weather-proof enclosures ■ Reduces installation & maintenance ■ Used with multiple Mustang Sampling® products such as the Mustang® P53, Pony® Probe En-

closure, Heated Regulators, MPRVSS, and the Mustang Intelligent Vaporizer Sample Conditioning System®

Along with the MSCS (Mustang® P53 Sampling Conditioning System with Pony® Probe

Enclosure), our Analytically Accurate®

patented power connection design is a standard among many companies and utilized with multiple Mustang

Sampling® products

Patented Power Connection

Sample Conditioning & Control

Page 4: Mustang Sampling Product Catalog

Mustang® P53 Sample Conditioning System (MSCS)

► cETLus Certified

► Patented technology delivers a heated sample to the analytical device utilizing

existing power supplied by heat trace sample tubing

► Ensures optimal performance of gas analyzers

► Maintains gas at least 30°F above the expected hydrocarbon dew point.

► Rated for Class 1, Group D, Div 1 locations

MODEL: P53 Remote, P53 Direct, Pony SCS, Custom designs within other enclosures

Pony® Probe Enclosure

► cETLus Certified

► Patented technology maintains heat at the sample point

► Ensures optimal performance of gas analyzers

► Maintains gas at least 30°F above the expected hydrocarbon dew point.

► Rated for Class 1, Group D, Div 1 locations

MODEL: PONY, Pony SCS, Solar Powered Pony SCS, Certicollar® adaptors for use with

multiple probe styles including the Mustang Certiprobe® Sample Extractor

Sample Conditioning Systems (SCS)

Page 5: Mustang Sampling Product Catalog

Mustang® Portable Sampling System—MHR

► Utilizes the Mustang® Heated Regulator

► Analysis at sample point

► Compact and portable

► Low power requirement

► Powered from truck inverter

► Preserves sample integrity from extraction point to analyzer

► 2 model options depending on your regulation needs

MODELS: MPHSS1

Mustang® Portable Sampling Systems—MJTHR

► Utilizes the Mustang® Joule Thomson Heated Regulator

► Analysis at sample point

► Compact and portable

► Low power requirement

► Powered from truck inverter

► Preserves sample integrity from extraction point to analyzer

► 2 model options depending on your regulation needs

MODELS: MPHSS2

Solar Powered Sample Conditioning System

► Patented technology maintains heat at the sample point

► Low Power Consumption

► Integral Sample Conditioning

► Minimum 5 days autonomy (runtime with no sun)

► Rated for Class I, Div I locations

Mustang® Bio-Gas Sample Conditioning System

► Conditions landfill or digester gas samples for green energy

► Maintains representative sample of low pressure feed gas

► Ensures optimal performance of gas analyzers

► Maintains gas at least 30°F above the expected

hydrocarbon dew point.

► Rated for Class 1, Group D, Div 1 locations

MODEL: MBGSCS for use with Pony® Probe Enclosures

Page 6: Mustang Sampling Product Catalog

Mustang® Regulators

► ATEX/IECEx & cETLus Certified

► CRN Approved

► MHR provides efficient heat transfer through pre-heat and post-heat chambers &

proportional temperature control

► MJTR offsets Joule-Thomson cooling

► High pressure options allow for higher inlet pressures

► Equations of State Phase Diagram determines heated and supercritical application

needs

MODEL: MR, MHR, MHR-I

Mustang® Joule-Thomson Regulators

► ATEX/IECEx & cETLus Certified

► CRN Approved

► MHR provides efficient heat transfer through pre-heat and post-heat chambers &

proportional temperature control

► MJTR offsets Joule-Thomson cooling

► High pressure options allow for higher inlet pressures

► Equations of State Phase Diagram determines heated and supercritical application

needs

MODEL: MJTR, MJTHR, MJTHR-I

Sample Regulation & Control

Page 7: Mustang Sampling Product Catalog

Mustang® Modular Analyzer Distribution Panel

► Modular design securely fits inside a heated cabinet with easy maintenance

► Single inlet pressure delivers to 4 locations

► Individually isolated outlet pressure

MODEL: MMADP, MMADPE w/ Enclosure for use in non-heated areas, Custom designs

within other enclosures

Mustang® Modular Sample Control Panels

► Class I Div I Enclosures

► Panel replacement w/o disconnecting tubing

► Direct replacement for new and existing analyzers

► API 14.1 Compliance

► Modular construction w/ field interchangeable parts and pieces

MODEL: MMSCP

Mustang® Moisture Analyzer System

► All-in-One Design with MSCS and Moisture Analyzer

► Patented technology delivers a heated sample to the analytical device utilizing

existing power supplied by heat trace sample tubing

► Ensures optimal performance of moisture analyzer

► Maintains gas at least 30°F above the expected hydrocarbon dew point.

► Rated for Class 1, Group D, Div 1 locations

► Modular construction w/ field interchangeable parts and pieces

MODEL: MMAS, Other Analyzer Enclosures Available

Page 8: Mustang Sampling Product Catalog

Mustang Certiprobe® Sample Extractor

► Conforms to ASME B 31.3-2014 & ISO 8943-2007

► Includes NDE; Dye Penetrant (PT), Hydrotest, and PMI (if requested)

► Fabricated to customer-specified metallurgy & rating

► Stress analysis as part of design process

► Suitable for LNG, LPG, & other process sampling

► Can be utilized with the Pony® Probe Enclosure

► Custom ANSI rating and length

MODEL: MCP

Mustang® Pressure Regulating Vaporizer Sampling System

► ATEX/IECEx Certified

► cETLus Certified

► Conforms to ASME B 31.3-2014 & ISO 8943-2007

► Includes NDE of PMI and DPI

► Fabricated to customer-specified metallurgy & rating

► Stress analysis prior to pipeline installation

► Suitable for LNG, LPG, & other process sampling

► Can be utilized with the Pony® Probe Enclosure

► Custom ANSI rating and length

MODEL: MV, MV-I

Mustang® Vacuum Jacketed Tubing

► Designed to ASME B31.3 for Pressure Piping

► Rigid or Flexible Tubing Options

► Prevents Pre-Vaporization

► Multi-layered insulation

► More efficient than conventional insulated lines

► Maintenance-Free

► Custom Project-Specific Designs

MODEL: VJTR, VJTF

LNG & NGL Vaporization & Regulation

Page 9: Mustang Sampling Product Catalog

Mustang® Pressure Regulating Vaporizer Sampling System—Sr.

► Conforms to ASME B 31.3-2014 & ISO 8943-2007

► Includes NDE of PMI and DPI

► Fabricated to customer-specified metallurgy & rating

► Stress analysis prior to pipeline installation

► Suitable for LNG, LPG, & other process sampling

► Can be utilized with the Pony® Probe Enclosure

► Custom ANSI rating and length

MODEL: MPRVSS (NGL Sr.)

Mustang® Pressure Regulating Vaporizer Sampling System—Jr.

► Conforms to ASME B 31.3-2014 & ISO 8943-2007

► Includes NDE of PMI and DPI

► Fabricated to customer-specified metallurgy & rating

► Stress analysis prior to pipeline installation

► Suitable for LNG, LPG, & other process sampling

► Can be utilized with the Pony® Probe Enclosure

► Custom ANSI rating and length

MODEL: MPRVSSJR (NGL Jr.)

Mustang® Liquid Sample Pump

► Patent pending

► Changes sample vapor to liquid

► Speed loop return

► Pneumatic system

► No need for electrical classification

► Teflon composite seals

MODEL: MLSP

Page 10: Mustang Sampling Product Catalog

Mustang Intelligent Vaporizer Sample Conditioning System®—Multipath North America

► Conforms to ISO 8943;CSA Approved for New

Brunswick Providence

► Continuous gas flow design eliminating post-vaporization hydrocarbon liquid dropout

► Accurate and reliable BTU measurements by your

analytical device

► Achieves redundancy in critical areas such as the loading and unloading of ships

► Optional software for operating, monitoring, trending, and reporting

MODEL: MIV-1 cETLus

Mustang Intelligent Vaporizer Sample Conditioning System®—Single Path—North America

► Conforms to ISO 8943;CSA Approved for New

Brunswick Providence

► Continuous gas flow design eliminating post-vaporization hydrocarbon liquid dropout

► Accurate and reliable BTU measurements by your

analytical device

► Suitable for areas such as storage and transfer where redundancy is not a concern

► Optional software for operating, monitoring, trending, and reporting

MODEL: MIV-2 cETLus

► STAGE 1—Available in either a multipath or single-

path design (see MIV2 brochure) to vaporize LNG

and send the sample to the accumulator for restruc-

turing

► STAGE 2—Accumulator cylinder designed with a spe-

cial impingement tube to allow the gas components

to return to their original composition

► STAGE 3—A pre and post-heated pressure regulator

designed to prevent hydrocarbon dew point drop-

out and reduce sample pressure which is then deliv-

ered to the chromatograph through a heated sam-

ple tube

► STAGE 4—Vapor return bypass flow control system

VAPORIZATION & REMIXING STAGES

LNG & NGL Intelligent Vaporization

Page 11: Mustang Sampling Product Catalog

Mustang Intelligent Vaporizer Sample Conditioning System®—Multipath International

► Conforms to ISO 8943;CSA Approved for New

Brunswick Providence

► Continuous gas flow design eliminating post-vaporization hydrocarbon liquid dropout

► Accurate and reliable BTU measurements by your

analytical device

► Achieves redundancy in critical areas such as the loading and unloading of ships

► Optional software for operating, monitoring, trending, and reporting

► ATEX/IECEx Certifiable

MODEL: MIV-1-I ATEX/IECEx

Mustang Intelligent Vaporizer Sample Conditioning System®—Single Path—International

► Conforms to ISO 8943;CSA Approved for New

Brunswick Providence

► Continuous gas flow design eliminating post-vaporization hydrocarbon liquid dropout

► Accurate and reliable BTU measurements by your

analytical device

► Suitable for areas such as storage and transfer where redundancy is not a concern

► Optional software for operating, monitoring, trending, and reporting

► ATEX/IECEx Certifiable

MODEL: MIV-2-I ATEX/IECEx

Mustang® Composite Sampling System

► Conforms to ISO 8943;CSA Approved for New

Brunswick Providence

► Continuous gas flow design eliminating post-vaporization hydrocarbon liquid dropout

► Accurate and reliable BTU measurements by your

analytical device

► Suitable for areas such as storage and transfer where redundancy is not a concern

► Optional software for operating, monitoring, trending, and reporting

► ATEX/IECEx Certifiable

MODEL: MIV-2-I ATEX/IECEx

Page 12: Mustang Sampling Product Catalog

[email protected] www.mustangsampling.com

MSB-LIN VOL. 4.1 ©2009-2016 MUSTANG SAMPLING, LLC. ALL RIGHTS RESERVED.

Locally Represented By:

Mustang Sampling® P 304-273-5357 F 304-273-2531

P.O. Box 490 Ravenswood, WV 26164

History of Sample Conditioning and Control The measurement and control industry has always had accuracy at the top of their priority list and we have been simplifying the process for many years. When we moved into the sampling aspect of our company, we began the design process that would become the foundation for many products to come. The Mustang® Sample Conditioning System was developed in 2004. A letter was sent out to the employees with a $100 award for the person that could come up with the perfect name for the system. Owners Ken & Brenda loved horses and Engineer, Walt, was passionate about the P51 Mustang fighter plane. With the fierce and reliant history of these images, the direct mount MSCS was named the P51 Mustang® Sample Conditioning System. The remote mount was titled the Pony® Heated Probe Enclosure. The first design was housed in a stainless steel box with heat tracing wrapped inside to keep the sample warm, and offset Joule-Thomson cooling (which results in inaccurate measurement). As the design progressed, heaters were used within the enclosures, but the patented design was still powered with the heat tracing used to power the box, eliminating the need for costly services to run rigid conduit to the sample point. In 2004, the initial design was finalized and taken to Dominion’s cold box testing facility in Clarksburg, WV. The sample was setup to take a large pressure drop within an environment ranging from -30 deg. F to 100 deg. F, which would be prime conditions for Joule-Thomson cooling and result in an accurate sample. Valtronics and Dominion left for dinner and then slept on it, and when they returned the next day (over 12 hours in the testing conditions), the sample held it’s temperature. To further prove the design, the MSCS was taken to the El Paso Corporation cold box in Houston, TX and passed that test with flying colors as well. In 2015, Mustang Sampling® became the main sponsor for the Action Express Racing No. 5 Chevrolet Corvette ( now the 2014-15 defending champion of the IMSA WeatherTech United SportsCar Championship) extending its global outreach through a sport near to many in the Oil & Gas industry. Growing up watching his father race in NASCAR, Ken has had a long history of passion for high quality machines built with innovation in mind—a force that drives Mustang Sampling® to constantly produce efficient solutions that work seamlessly for our customers.

Mustang Sampling® was developed as a sister-company to Valtronics and continues to develop and provide Analytically Accurate® products for measurement and control.