museum layout 1 - advanced filtration · hbr, hcl, nox, so2, so3, hydrocarbons, organics inorganic...

4
IN-VITRO FERTILIZATION LABORATORIES IIIIIIIIIIIIIIIIIIIIII

Upload: dangthuy

Post on 15-Mar-2019

230 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Museum Layout 1 - Advanced Filtration · HBr, HCl, NOx, SO2, SO3, hydrocarbons, organics inorganic chlorides NOx, many ... NOx = Nitrogen oxides, S = Sulfur, SO2 = Sulfur dioxide,

IN-VITROFERTILIZATIONL A B O R A T O R I E S I I I I I I I I I I I I I I I I I I I I I I

Page 2: Museum Layout 1 - Advanced Filtration · HBr, HCl, NOx, SO2, SO3, hydrocarbons, organics inorganic chlorides NOx, many ... NOx = Nitrogen oxides, S = Sulfur, SO2 = Sulfur dioxide,

CLEAN A IR SOLUT IONS 4 IN -V I TRO FERT I L I ZAT ION LABORATOR IES

C O N T R O L L I N G A M C + I N C R E A S I N G S U C C E S S R A T E S

A M C & S U C C E S S R A T E S

The term airborne molecular contamination (AMC) refers to the presence of unwanted gas-phasecontaminants in the cleanroom. Effects of AMC in IVF labs have been shown to be very significant, causinga threefold decrease in success rates. AMC filtration has been proven to dramatically affect the IVF lab oper-ation and increase pregnancy rates.

Purafil is the world leader in gas-phase air filtration and monitoring technologies. With more than 30 yearsof experience in the engineering and manufacture of clean air solutions, Purafil offers a comprehensiveproduct and service offering for IVF laboratories and cleanroom customers.

U N D E R S T A N D I N G A M C

Factors that contribute to the overall AMC load to a cleanroom areoutdoor air, manufacturing processes, fugitive emissions fromprocess equipment, chemical storage areas, off-gassing from build-ing and construction materials, accidental spills, and bioeffluentsfrom personnel.

Outdoor air is many times considered a clean source of dilution airto reduce internal contaminant levels. However, outdoor air can bea source of multiple contaminants. These contaminants, mentionedin Table 1, have the potential to be introduced through the outside

air intakes of the HVAC system, unless the air is cleaned of thosecontaminants.

Internal contaminant sources that can affect IVF labs include analytical procedures, cleaning processes, compressed air, pesticideuse, building material off-gassing and the personnel themselves.These sources and their contaminants are listed in Table 2.

S O U R C E S A N D C O N T A M I N A N T S I N O U T D O O R A I R

HBr, HCl, NOx, SO2, SO3, hydrocarbons, organicsinorganic chloridesNOx, many organicsHClH2S, NH3, S, SO2, hydrocarbons, mercaptans, organicsH2S, SO2CH4, H2S, NH3NaCl, chloride ionsNH3, SO2, alcohols, aldehydes, organicsNOx, SO2, hydrocarbons, organicsH2S, NH3, S, aldehydes, mercaptans, organics

AUTOMOT IVE COMBUST IONCOOL ING TOWERSD IESEL COMBUST IONFOREST F IREFOSS I L FUEL PROCESS INGGEOTHERMAL PROCESSESL IVESTOCK AREASOCEANSPLAST IC MANUFACTUREPOWER GENERAT IONSEWAGE

C O N T A M I N A N T S E M I T T E D F R O M I N T E R N A L S O U R C E S

SOURCE CONTAMINANTS EMITTED

ammonia, alkanes, alkenes, aromatics, turpenesNOx, formaldehyde, PAHs, respirable particlebacteria, insects, moldbenzene, chlorinated hydrocarbons, formaldehydearomatics, alcohols, aldehydes, ketonesethylene oxide, chlorine, chlorine dioxide, ozonebenzenes, formaldehyde, NOx, PAHs, VOCs

CLEANING PRODUCTSCOMBUST ION SOURCESDAM/WET AREASFURNISH INGS, WOODPERSONNELSTER I L I ZAT ION PROCESSESTOBACCO SMOKE

SOURCE CONTAMINANTS EMITTED

3

SeSAVINGENERGY

2

PoPREVENTING

ODORS

1

IaqIMPROVINGINDOOR AIR

CH4 = Methane, HBr = Hydrogen bromide, HCl = Hydrogen chloride, H2S = Hydrogen sulfide, NaCl = Sodiumchloride, NH3 = Ammonia, NOx = Nitrogen oxides, S = Sulfur, SO2 = Sulfur dioxide, SO3 = Sulfur trioxide

TA B L E 1

TA B L E 2

Page 3: Museum Layout 1 - Advanced Filtration · HBr, HCl, NOx, SO2, SO3, hydrocarbons, organics inorganic chlorides NOx, many ... NOx = Nitrogen oxides, S = Sulfur, SO2 = Sulfur dioxide,

F I LT R A T I O N O F A M C

AMC requires different filtration methods than those used on particulate contaminants.HEPA filtration will provide a medium to capture particles of very small diameters, butthe airborne molecular contaminants will persist in the air.

For control of AMC, Purafil offers a variety of patented, dry-scrubbingmedia that remove contaminants via adsorption — a physical process where contami-nants adhere to the media’s surface — and chemisorption — an instantaneous and irreversiblechemical reaction where contaminants are transformed into harmless solids and remain trapped inside the media. Purafil media havea high surface area to mass ratio and contain chemical impregnants to target and eliminate contaminants of concern. Purafil mediaare engineered and manufactured at company headquarters, according to strict ISO 9001:2000 quality procedures

Purafil® SP Blend media is a combination of Purakol® media, a premium grade activated carbon, and Purafil® SP media, an activat-ed alumina substrate impregnated with the active ingredient sodium permanganate. Purafil® SP Blend media demonstrates a highremoval capacity for combustion gases found in outdoor air as well as emissions from furnishings, cleaning products, sterilizationprocesses, and other internal sources.

Certain applications may require the use of another media in place of or in addition to Purafil SP Blend, such as Purakol® AM mediafor control of ammonia, Purafil® Triple-Blend Makeup Air media for removal of diesel exhaust contaminants, or Chlorosorb® Ultramedia for control of chlorine.

T H E P U R A F I L A I R P U R I F I C A T I O N S Y S T E M

The Purafil system (at right) features pre-filter and final filter sections for control of particulatecontaminants and one or two passes of Purafil mediamodules for removal of gases and odors. The Purafil

system can be employed in two ways: (1) As apart of the facility’s HVAC system to

clean the air entering the IVF lab and(2) As a standalone filtration solu-

tion to clean and recirculate airin specific process areas.

T H E P U R A F I L S I D E A C C E S SSYSTEM (PSA )

The PSA is designedfor both particulate andgeneral odor control andworks in conjunction with

the facility’s air handling sys-tem. The PSA is a built-to-order

system available in more than20 size options. A full range of pre-

filter selections and particulate finalfilter selections are also available.

THE PURAF I L POS IT IVE PRESSUR IZAT ION UN IT(PPU )

The PPU is designed to be wall-mounted or on cast-ers for mobility. The system operates by drawingroom air through a vent located at thetop of the unit and through particu-late and chemical filtration sec-tions before being dischargedthrough a vent located at thebottom of the unit. The PPUmaintains clean air in localizedareas of the facility.

PAR T ICULATEPRE - F I LTER

PURAF I L MED IAMODULE

PAR T ICULATEF INAL F I LTER

THE PURAF I L ® S IDE ACCESSSYSTEM (PSA )

Page 4: Museum Layout 1 - Advanced Filtration · HBr, HCl, NOx, SO2, SO3, hydrocarbons, organics inorganic chlorides NOx, many ... NOx = Nitrogen oxides, S = Sulfur, SO2 = Sulfur dioxide,

Distributed By:

323.832.8316 z www.ADVfiltration.com