ms/ms spectral library with embedded linear … · ms/ms spectral library with embedded linear...
TRANSCRIPT
MS/MS SPECTRAL LIBRARY WITH EMBEDDED LINEAR RETENTION INDICES: UNIQUE
SUPPORT FOR A RELIABLE NON-TARGETED PESTICIDE IDENTIFICATION
E. Trovato 1, M. Utczás 1,2, F. Alibrando 1, F. Vento 1, Luigi Mondello 1,3
1 Chromaleont s.r.l., c/o University of Messina, Polo Annunziata I-98168, Messina, Italy2 Center of Sports Nutrition Science, University of Physical Education, H-1123,
Budapest, Hungar3 Dipartimento di Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali,
University of Messina, Polo Annunziata, I-98168, Messina, Italy
Chro
maleon
twww.chro
maleon
t.it
40th International Conference on
Environmental & Food Monitoring, Santiago
de Compostela (Spain) 19-22 June 2018
Identification in GC-MS
Chro
maleon
twww.chro
maleon
t.it
✓Commercial libraries
✓Chromaleont GC-MS libraries✓Commercial libraries
✓Chromaleont GC-MS libraries
MS spectrum
50.0 100.0 150.0 200.0 250.00
5
10
15
20
25%
125 204
89
4113863 102
113 23977
5.0 15.0 25.0 35.0 45.0 55.0 65.0 75.0 85.00
0.2
0.4
0.6
0.8
1.0
1.2
tR(z+1)
tRi
tRz
5.0 10.0 15.0 20.0 25.0 30.0 35.0
0.05
0.25
0.45
0.65
0.85
1.05
C8
C9
C10
C11
C12
C13
C14
C15
C7
Linear retention index (LRI)
Retention behavior as identification parameter
At the 1st analysis
Intraday (48 h) repeatability of retention time
At the 35th analysis
At the 15th analysis
0.1 min (6 s)
Chro
maleon
twww.chro
maleon
t.it
The absolute retention time
varies not only with all
chromatographic variables
(temperature program, gas
linear velocity, phase ratio
and column length) but also
between normal runs on the
same column
26.00 26.05 26.10 26.15 26.20 26.25 26.30 26.35 26.40
2.5
5.0
7.5
(x100,000)
5.0 15.0 25.0 35.0 45.0 55.0 65.0 75.0
0.05
0.25
0.45
0.65
0.85
1.05(x1,000,000)
GC-MS chromatogram n-alkanes (C7-C30)
Linear retention index (LRI) approach
Chro
maleon
twww.chro
maleon
t.it
Linear retention index for a specific analyte (LRI) [1,2]:
LRI = 100n[(tRi-tRz)/(tR(z+1)-tRz)]+100z
z: carbon atom number
n: the difference in carbon atom number of the two standards
(n-alkanes: n=1, even or odd FAMEs and FAEEs: n=2)
[1] H. Van den Dool and P.D. Kratz, J. Chromatogr. 11 (1963) 463
[2] M.B. Evans and J.F. Smith, J. Chromatogr. 8 (1962) 303
tR(z+1)
tRztRi
10 20 30 40 50 60 70 80
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
(x1,000,000)
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19 C20
C21
C22 C
23 C
24 C25
C26
C27
C28
C29
C30
C10
C11
LRI: 1031
LRI: 1000LRI: 1100
Chro
maleon
twww.chro
maleon
t.it
Linear retention index for a specific analyte (LRI)
LRI = 100n[(tRi-tRz)/(tR(z+1)-tRz)]+100z
z: carbon atom number
n: the difference in carbon atom number of the two
standards
(n-alkanes: n=1, even or odd FAMEs and FAEEs: n=2)
tR(z+1)
tRi
tRz
Linear retention index (LRI) approach
Compound type LRI range
Average peak width
at half height
(LRI)
Average peak width
at half height
(s)
Super volatile <800 2 2.16
High volatile 800 1200 2 3.00
Volatile 1200 1600 2 3.96
Medium volatile 1600 2000 2 3.72
Low volatile >2000 3 4.02
Chro
maleon
twww.chro
maleon
t.it
LR
I (u
nit
)0
500
1000
1500
2000
2500
3000
0 20 40 60 80
tr (min)
Linear retention index (LRI) approach
Mass spectral databases on the market
Library Name DateEI MS
spectraMS/MS spectra
GC and retention
index records
NIST MS '17 (recommended base library) 2017-06 NEW 306622 652475 404045
NIST GC '17 (included with NIST MS) 2017-06 404045
NIST MSMS '17 (included with NIST MS) 2017-06 652475
Wiley Registry 11th 2016-03 775550
Wiley 10th+NIST14 combined 2014-11 918000 234284 346757
Wiley METLIN Mass Spectral Database 2017 NEW >72000 (+ NISTMSMS)
Wiley Lipids Mass Spectral Database 2017 NEW 430
Wiley Pesticides Mass Spectral Library with LRI, 2nd Edition 2017 NEW
Wiley Designer Drugs 2016-06 23477
(include
~12700
Wiley Flavors/Fragrances (FFNSC), 3rd Edition 2014-12 3462 Yes
Wiley Drugs/Poisons/Pesticides/Pollutants & Metabolites(Maurer/Pfleger/Weber) 2017 NEW 10430 Yes
Wiley LC-MSn Library of Drugs, Poisons and Their Metabolites(Maurer/Wissenbach/Weber) 2014 >10000
Wiley FAMEs Fatty Acid Methyl Esters: Mass Spectral Database 2011-11 240 YES
Wiley Physiologically Active Substances (drugs, steroid hormones, and endocrine disruptors) 2011-05 4182
Wiley Pesticides (Rolf Kühnle) 2009 1238
Wiley Androgens/Estrogens/Steroids 2008 3722
Wiley Organic Compounds 2004 37055
Wiley Geochemicals/Petrochemicals/Biomarkers 2003 1100
Wiley Tandem MSMS (MSforID) 2012 Mar 12048
NIST17 supersedes NIST14.
Chart lists number of spectra or data records for each library.
Many libraries contain Linear Retention Indices (LRI) calculated by using different
columns (e.g. non polar, polar, medium polarity)
But these values represent only an average of the experimental data
obtained by various authors
NO ACCURATE searching!
Chro
maleon
twww.chro
maleon
t.it
• Retention index types in the databases: Normal alkane RI, Linear RI, Kovats RI
• Average experimental RI values and estimated values based purely on
structure
• Average retention index: expressed as the median of experimental RI on similar
stationary phases with standard deviation
median ± standard deviation (n: number of values used for the calculation)
• Retention index prediction: from the cited values of the given compound or
structurally related compounds in the database on non-polar stationary phase (n-
alkane scale)
estimated value
confidence interval (diverse functional groups) at 50% and 95% confidence level
Chro
maleon
twww.chro
maleon
t.it
Mass spectral databases on the market
Propanil
Estimated non-polar retention index (n-alkane scale): Value: 1752
Confidence interval (Diverse functional groups): 89(50%) 382(95%) iu
Column type median RI SD n experimental LRI
Standard non-polar 1669 24 4 1611
Semi-standard non-polar 1746 8 30 1748
Bromoxynil
Estimated non-polar retention index (n-alkane scale): Value: 1818
Confidence interval (Diverse functional groups): 89(50%) 382(95%) iu
ΔLRI: +207
Column type median RI SD n experimental LRI
Standard non-polar 1836 8 4 1815
Semi-standard non-polar 1863 10 11 1872
Polar 3197 0 1 -
ΔLRI: +63ΔLRI: +21
ΔLRI: +58
Chro
maleon
twww.chro
maleon
t.it
Mass spectral databases on the market
Metamitron
Estimated non-polar retention index (n-alkane scale): Value: 1977
Confidence interval (Diverse functional groups): 89(50%) 382(95%) iu
Column type median RI SD n experimental LRI
Standard non-polar 1919 5 3 1899
Semi-standard non-polar 1938 10 7 1942
Ethofumesate
Estimated non-polar retention index (n-alkane scale): Value: 2102
Confidence interval (Diverse functional groups): 89(50%) 382(95%) iu
ΔLRI: +103
Column type median RI SD n experimental LRI
Standard non-polar 2139 0 1 2184
Semi-standard non-polar 2193 2 2 2206
ΔLRI: +207ΔLRI: +45
ΔLRI: +20
Chro
maleon
twww.chro
maleon
t.it
Mass spectral databases on the market
A comprehensive database was realized containing the MS spectra of about 1300
pure compounds. Each component is associated to multiple LRIs calculated by using
different columns and n-alkanes homologous series.
Experimental LRI conceptOur concept of MS spectral database is different from the other
The concept of stability of LRIs was emphasized
To obtain a reliable identification a filter window of ±5 LRI units should be used
Chro
maleon
twww.chro
maleon
t.it
HIT CAS Common name Molecular
weight
Molecular
formulaLRIlib LRIexp1 LRIexp2 LRIexp3 LRIaverage
Repeatibility
intralaboratoryΔLRI
562 1194 - 65 - 6 Dichlobenil 171 C7 H3 Cl2 N 1332 1334 1336 1335 1335 1.0 3
596 759 - 94 - 4 EPTC 189 C9 H19 N O S 1352 1356 1352 1356 1355 0.9 3
526 1918 - 16 - 7 Propachlor 211 C11 H14 Cl N O 1601 1605 1604 1606 1605 1.2 4
639 81777 - 89 - 1 Clomazone 239 C12 H14 Cl N O2 1746 1750 1748 1747 1748 0.6 2
527 709 - 98 - 8 Propanil 217 C9 H9 Cl2 N O 1872 1874 1873 1876 1874 0.7 2
643 61213 - 25 - 0 Flurochloridon 311 C12 H10 Cl2 F3 N O 2012 2009 2010 2011 2010 0.5 -2
536 101 - 27 - 9 Barban 257 C11 H9 Cl2 N O2 2186 2184 2187 2189 2187 0.4 2
551 74070 - 46 - 5 Aclonifen 264 C12 H9 Cl N2 O3 2269 2272 2275 2271 2273 1.1 4
525 137641 - 05 - 5 Picolinafen 376 C19 H12 F4 N2 O2 2465 2470 2467 2469 2469 0.9 3
578 66441 - 23 - 4 Fenoxaprop ethyl ester 361 C18 H16 Cl N O5 2656 2661 2660 2658 2660 0.9 3
588 76578 - 14 - 8 Quizalofop-ethyl 372 C19 H17 Cl N2 O4 2834 2835 2840 2838 2838 1.3 5
541 142891 - 20 - 1 Cinidon ethyl 393 C19 H17 Cl2 N O4 3191 3200 3189 3194 3194 0.3 1
Identification in GC-MS
Chro
maleon
twww.chro
maleon
t.it
GCMS Solution SoftwareHighly Reliable
Identification
✓Commercial libraries
✓Chromaleont GC-MS libraries✓Commercial libraries
✓Chromaleont GC-MS libraries
MS spectrum
50.0 100.0 150.0 200.0 250.00
5
10
15
20
25%
125 204
89
4113863 102
113 23977
5.0 15.0 25.0 35.0 45.0 55.0 65.0 75.0 85.00
0.2
0.4
0.6
0.8
1.0
1.2
tR(z+1)
tRi
tRz
5.0 10.0 15.0 20.0 25.0 30.0 35.0
0.05
0.25
0.45
0.65
0.85
1.05
C8
C9
C10
C11
C12
C13
C14
C15
C7
Linear retention index (LRI)
Inject the sample
WORK-FLOW
Inject the standard series (n-
alkanes) using the same
chromatographic method as the
sample
Register the retention time of each
standard compound and assign it the
conventional LRI value (e.g.
C10=1000). Save the data file
Calculate the LRI of your target
molecule according to your
standard mixture
Compare the LRI value with the
value reported in the Library
Load retention time series
from the data file
Use linear retention index filter
simultaneously with MS similarity
search in the Library
Manual GCMSsolution
Chro
maleon
twww.chro
maleon
t.it
PESTICIDES GC-MS Library
The most extensive pesticide database
New version included also metabolites and artifacts
for a total of 1300 compounds
925 compounds
Columns made by Merck-Millipore
(length 30m × inner diameter 0.25mm × film thickness 0.25μm)
ColumnReference
seriesNo.
SLB-5ms ALKANEs 1300
EQUITY-1 ALKANEs 147
Chro
maleon
twww.chro
maleon
t.it
PESTICIDES GC-MS Library Ver. 2
Containing:
✓ Systematic name
✓ Common name
✓ CAS number
✓ Molecular weight
✓ Molecular formula
✓ Molecular class
✓ Standard and column
information
✓ 2 experimental LRI values
Class No.
Adjuvants 12
Acaricides 93
Alkanes 34
Artifacts/Degradation products 63
Avicides 1
Bactericides 29
Fungicides 187
Herbicides 248
Insecticides 236
Molluscicides 7
Nematicides 11
Pesticides 112
Pesticides intermediers 48
Pesticides metabolites 80
Pheromones 56
Plant growth regulators 37
Preservative 2
Repellents 17
Rodenticides 10
Solvents 17
Total 1300
Chro
maleon
twww.chro
maleon
t.it
Identification of HCH isomers
1,000 times more
toxic than other
diastereomers
Chro
maleon
twww.chro
maleon
t.it
Identification of HCH isomers
with two independent analytical information
50 100 150 200 250 3000.0
5.0
(x1,000)181
219
111 217
51
14777
254121 15896 290258193 234
GCMSsolution MS similarity filter (>90%)
Chro
maleon
twww.chro
maleon
t.it
Identification of HCH isomers
with two independent analytical information
?
By using only the MS similarity filter the identification is
not reliable!
GCMSsolution MS similarity filter (>90%)
Chro
maleon
twww.chro
maleon
t.it
50 100 150 200 250 3000.0
5.0
(x1,000)181
219
111 217
51
14777254121 15896 290258193 234
50 100 150 200 250 300
0.0
5.0
(x1,000)181
219
111 217
51
14777254121 15896 135 290258193 234
50 100 150 200 250 3000.0
5.0
(x1,000)181
219109
51
85 1458773 216113 156 254133 169 292193 277235
Identification of HCH isomers
with two independent analytical information
GCMSsolution MS similarity filter (>90%) and ±5 LRI filter
Chro
maleon
twww.chro
maleon
t.it
Chro
maleon
twww.chro
maleon
t.it
!
Identification of HCH isomers
with two independent analytical information
GCMSsolution MS similarity filter (>90%) and ±5 LRI filter
The LRI filter allows to obtain one single match
excluding possible wrong identification
2,4 isomer:
insecticide activity
Other positional isomers:
nematicide activity
Chro
maleon
twww.chro
maleon
t.it
Identification of dimethyl phenol isomers
?
Identification of dimethyl phenol isomers
LRI: 1146
Chro
maleon
twww.chro
maleon
t.it
50.0 75.0 100.0 125.00.0
5.0
(x1,000)107 122
779151
65 10355 80 8974 119
50.0 75.0 100.0 125.00.0
5.0
(x1,000)107 122
779151
65 10355 8074 89 11995 125110130
50.0 75.0 100.0 125.00.0
5.0
(x1,000)107 122
779151
65 10355 80 8974 11995
10 20 30 40 50 60 70 80
0.5
1.0
1.5
2.0
2.5
3.0
3.5(x10,000,000)
Identification of dimethyl phenol isomers
The LRI filter allows to obtain one single match
excluding possible wrong identification !
According to MS similarity search a long list of candidates
can be obtained with almost identical similarity
Chro
maleon
twww.chro
maleon
t.it
Advantages:
• Non-target pesticide identification
• Reduced false-positive and negative identification
• 50% coverage of the EU Pesticides Database and the
Japan Positive List
10 20 30 40 50 60 70 80
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
(x1,000,000)TIC
1,2
-Dic
hlo
robenzene
Eth
iola
te
Dic
hlo
benil
EP
TC
Pebula
teT
ebuth
iuro
nM
ecopro
pm
eth
yleste
r
MC
PA
meth
yleste
r
Pro
pachlo
rA
trazin
e-d
esis
opro
pyl
Sulfalla
teIs
opro
pyl2,4
-D e
ste
rC
lom
azone
Pro
flura
linA
zip
rotr
yn
Monalid
eP
ropanil
Medin
ote
rb a
ceta
teE
thofu
mesate
Flu
rochlo
ridon
isom
er
I
Chlo
rflu
recol-m
eth
yl
Halo
xyfo
p-m
eth
yl
Flu
oro
difen
Barb
an A
ciflu
orf
en
meth
yleste
rA
clo
nifen
TD
CP
PC
hlo
ridazon
Flu
roxypyr
1-m
eth
ylh
epty
l
este
rN
itra
lin
Pic
olin
afe
n
Mefe
nacet
Fenoxapro
peth
yleste
r
Quiz
alo
fop-P
-eth
yl
Flu
ridon
Pyridate
Cin
idon
eth
yl
Chro
maleon
twww.chro
maleon
t.it
Reliable non-target identification
using Pesticides Library
0
• Low limit of identification and quantification
Chro
maleon
twww.chro
maleon
t.it
26.50 26.75 27.00 27.25 27.50 27.75 28.00 28.25 28.50 28.75 29.00 29.25 29.50 29.75 30.00
0.25
0.50
0.75
1.00
1.25
1.50
(x1,000,000)
26.50 26.75 27.00 27.25 27.50 27.75 28.00 28.25 28.50 28.75 29.00 29.25 29.50 29.75 30.00
0.50
0.75
1.00
1.25
1.50
1.75(x100,000)
100 ppm
10 ppm
Identification of a spectrum acquired in Fullscan
mode by Shimadzu GCMS-TQ8040
Dic
hlo
be
nil
Dic
hlo
be
nil
S/N = 5
0
0.25
171
136100
TIC
Chro
maleon
twww.chro
maleon
t.it
1 ppm
• Low limit of identification and quantification
The compound signal at 1 ppm level is similar to the baseline signal. The
use of LRI index makes possible the identification
Identification of a spectrum acquired in Fullscan
mode by Shimadzu GCMS-TQ8040
Dic
hlo
be
nil
S/N ~ 0 TIC171
136100
91 Similarity
Chro
maleon
twww.chro
maleon
t.it
27.0 27.1 27.2 27.3 27.4 27.5 27.6 27.7 27.8 27.9 28.0 28.1 28.2
0.25
0.50
0.75
1.00
1.25
1.50
1.75
2.00
2.25
(x1,000)
At the same concentration, the signal of the compound aquired
in MRM mode is much higher respect to those in full scan mode
Identification of a spectrum acquired in MRM
mode by Shimadzu GCMS-TQ8040
Dic
hlo
be
nil
170.90>110.00 (7.02)
170.90>136.00 (1.10)
170.90>100.00 (1.00)
TIC
Chro
maleon
twww.chro
maleon
t.it
Good capability to reach lower identification
and quantification limits
y = 12.404,194x + 806,267
R² = 1,000
0
200000
400000
600000
800000
1000000
1200000
1400000
0 20 40 60 80 100
Pea
k a
rea
(-)
Absolute quantity (pg)
Dichlobenil
Identification of a spectrum aquired in MRM mode
(by Shimadzu GCMS-TQ8040)
Chro
maleon
twww.chro
maleon
t.it
By using only the MS similarity filter the identification is not reliable!
Identification of a spectrum aquired in MRM mode
(by Shimadzu GCMS-TQ8040) with MRM library
and CromatoPlusSpectra Software
170.90>110.00 (7.02)
170.90>136.00 (1.10)
170.90>100.00 (1.00)
Aquisition time window: 27.00-28.25 min
Chro
maleon
twww.chro
maleon
t.it
By using only the MS similarity filter the identification is not reliable!
Identification of a spectrum aquired in MRM mode
(by Shimadzu GCMS-TQ8040) with MRM library
and CromatoPlusSpectra Software
✔
170.90>110.00 (7.02)
170.90>136.00 (1.10)
170.90>100.00 (1.00)
Chro
maleon
twww.chro
maleon
t.it
By using only the MS similarity filter the identification is not reliable!
Identification of a spectrum aquired in MRM mode
(by Shimadzu GCMS-TQ8040) with MRM library
and CromatoPlusSpectra Software
Chro
maleon
twww.chro
maleon
t.it
Identification of a spectrum aquired in MRM mode
(by Shimadzu GCMS-TQ8040) with MRM library
and CromatoPlusSpectra Software
Chro
maleon
twww.chro
maleon
t.it
The LRI filter allows to
obtain one single match
excluding possible wrong
identification
Identification of a spectrum aquired in MRM mode
(by Shimadzu GCMS-TQ8040) with MRM library
and CromatoPlusSpectra Software
Chro
maleon
twww.chro
maleon
t.it
• The use of triple quadrupole (QqQ) MS as a detector offers
advantages due to its high sensitivity and reproducibly
generated spectra
• Possibility to identify unknown compounds at a
concentration level 10 times lower than the legal limit
• On the market only a limited number of MS/MS libraries
can be found, furthermore using only spectral information in
many cases misidentification could occur due to the highly
similar fragmentation pattern even after the collision.
Remarks
Chro
maleon
twww.chro
maleon
t.it• The simultaneous use of spectral similarity and LRI filter
information in the integrated MS/MS-LRI database makes
automatic the identification procedure, reduces false-positive
and negative identification, and provides an important
support in untargeted pesticide analysis
• The Linear Retention Indices (LRI) approach used in
combination with mass spectral search is a powerful
tool for boosting the reliability of the identification of
challenging molecules and also decrease significantly
the limit of identification (LOI).
Remarks
Thank you for your kind
attention!
Chro
maleon
twww.chro
maleon
t.it