Give your access control system wings. www.mercury-security.com MS Bridge MS-ACS As part of Mercury Security’s mission to design and build a completely open access control hardware platform with a highly articulated API, the new MS-ACS Bridge offers a direct retrofit of Software House’s ® Pro Series ACM module. The MS-ACS Bridge is a multi-device interface panel that replicates the Pro Series ACM access control hardware form factor for fast “screwdriverless” change over and easy migration of Software House ® client infrastructure to any Authentic Mercury software partner solutions. Built on the Authentic Mercury platform, the MS-ACS interface panel provides the ability to control access for eight openings and interfaces with an array of reader technologies: Weigand or clock and data protocol based-readers capable of being individually configured. Additionally, the MS-ACS has the native capability to monitor the door position, manage the door locking hardware and request-to-exit devices. Additional Benefits: Simple Migration – Provides a streamlined path to move organizations from proprietary and/or legacy systems to open platforms, while reducing overall costs by eliminating the need to rewire legacy peripheral devices. Open and Flexible – The Authentic Mercury hardware platform is based on open architecture access control technology, which is designed to support emerging technologies, changing industry standards and evolving system environments. Market-Proven: – With the industry’s largest installed base and greatest accumulated runtime of any access hardware provider, Mercury Security has consistently provided partners and customers with the most reliable and scalable platform for more than 20 years. Application Notes The MS-ACS is an integral component in the Mercury MS Bridge family approach to migrate Pro Series hardware to flexible, feature-rich Mercury access hardware. When paired with a MS-ICS, customers can begin reaping the benefits of the industry leading, open Authentic Mercury access control platform. Features 8 reader capacity supporting multiple open reader technologies Universal I/O device characterization AES 128 bit data encryption Benefits Retrofits Pro Series ACM modules from Software House ® Built on the Open Authentic Mercury platform The MS-ACS interface panel is supported by the MS-ICS and offers the complete library of Mercury functionality, just as the R8S and I8S products.

Upload: others

Post on 26-Apr-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MS Bridge MS-ACS - Open Options · 2017. 9. 21. · Give your access control system wings. MS Bridge MS-ACS As part of Mercury Security’s mission to design and build a completely

Give your access control system wings.www.mercury-security.com

MS Bridge

MS-ACSAs part of Mercury Security’s mission to design and build a completely open access control hardware platform with a highly articulated API, the new MS-ACS Bridge offers a direct retrofit of Software House’s® Pro Series ACM module.

The MS-ACS Bridge is a multi-device interface panel that replicates the Pro Series ACM access control hardware form factor for fast “screwdriverless” change over and easy migration of Software House® client infrastructure to any Authentic Mercury software partner solutions.

Built on the Authentic Mercury platform, the MS-ACS interface panel provides the ability to control access for eight openings and interfaces with an array of reader technologies: Weigand or clock and data protocol based-readers capable of being individually configured. Additionally, the MS-ACS has the native capability to monitor the door position, manage the door locking hardware and request-to-exit devices.

Additional Benefits:

• Simple Migration – Provides a streamlined path to move organizations from proprietary and/or legacy systems to open platforms, while reducing overall costs by eliminating the need to rewire legacy peripheral devices.

• Open and Flexible – The Authentic Mercury hardware platform is based on open architecture access control technology, which is designed to support emerging technologies, changing industry standards and evolving system environments.

• Market-Proven: – With the industry’s largest installed base and greatest accumulated runtime of any access hardware provider, Mercury Security has consistently provided partners and customers with the most reliable and scalable platform for more than 20 years.

Application Notes

The MS-ACS is an integral component in the Mercury MS Bridge family approach to migrate Pro Series hardware to flexible, feature-rich Mercury access hardware. When paired with a MS-ICS, customers can begin reaping the benefits of the industry leading, open Authentic Mercury access control platform.

Features

• 8 reader capacity supporting multiple open reader technologies

• Universal I/O device characterization

• AES 128 bit data encryption

Benefits

• Retrofits Pro Series ACM modules from Software House®

• Built on the Open Authentic Mercury platform

• The MS-ACS interface panel is supported by the MS-ICS and offers the complete library of Mercury functionality, just as the R8S and I8S products.

Page 2: MS Bridge MS-ACS - Open Options · 2017. 9. 21. · Give your access control system wings. MS Bridge MS-ACS As part of Mercury Security’s mission to design and build a completely

The Authentic Mercury open platform delivers quality assurance derived from the most proven and reliable hardware in the industry. Driven by our engineering excellence and technology leadership, Authentic Mercury hardware is designed as an access control platform that easily encompasses emerging technologies, changing industry standards and evolving system environments. Make yours Authentic, Make sure its Merc.

MS Bridge

The MS-ACS is for use in low voltage, Class 2 Circuits only.

Primary Power: 12 Vdc, ± 10 %, 3.0 A maximum

Communication: 9600, 19200, 38400, or 115200 bps, asynchronous

Inputs: 16 unsupervised/supervised, standard EOL: 500/1K/1K ohm, 1 %, ¼ watt

Outputs: 8 outputs, Form-C, 2.5 A @ 30 Vac/dc, resistive

Reader Interface Power: 5 to 12 Vdc regulated, 350 mA maximum each reader port

Reader Data Inputs: TTL compatible inputs

Reader Data: Use shielded cables Cable Requirements: 1 twisted pair per input, 22 AWG shielded. RS-485: 24AWG, 120 ohm impedance, twisted pair with shield, 4,000 ft. (1,200 m) maximum

Alarm Inputs: 30 ohms maximum loop resistance

Outputs: As required for the load

12 Vdc: 20 AWG, 500 feet maximum, reader powered by MS-ICS board 18 AWG, 3000 feet maximum, reader powered locally

Dimensions: W 4.65 in (118 mm) L 12.25 in (311 mm) H .65 in (16.5 mm)

Weight: 9.35 oz. (265 g) nominal without connectors Environmental:Temperature: -20 TO +70 °F storage, 0 to +50 °C operational

Humidity: 5 to 95% RHNC

Standards: UL 294 Recognized, CE Compliant, RoHS, FCC Part 15 Class A

Note: The above specifications are based on the typical 12 volt reader drawing 125 mA. Reader power requirements vary between different models. Excessive voltage drop on long cable runs may require a larger cable gauge or powering the reader from a local power source. Refer to the power specification for the reader being installed.

®Software House (Reg. No. 3010766) is a registered trademark of Sensormatic Electronics LLCMercury Security Products is not affiliated with or sponsored by Sensormatic Electronics LLC, Software House, or Tyco International Ltd

D8

D7

D10

D9

D14

D13

D12

D11

TB18

TB20

TB22

TB24

12V

MS_ACS December 2016

MS-ACS

Network Switch

MS-ICS

MR16inMR16out

Door 1

CAT5/CAT 6

To Mercury OEM Host

MR52

Door 1

S1

1

1 2 43 5 12976 8 13 1410 11 15 16

TB10

TR+

GND

R+4W

R-

2W

TR-

RS-485

GND

VIN

GND

BA

CT

GN

D

TB9

TB11

J2J1

J1, J2RS-485TERM

NC

C

NO

NC

C

NO

OUT 8

OUT 7

TB4

K8

NO

C

NC

NO

C

NCOUT 6

OUT 5

NO

C

NC

NO

C

NC

OUT 4

OUT 3

NO

C

NC

NO

C

NCOUT 2

OUT 1

TB3

K7TB

2TB

1

2W4W

J3

U1

J6

J5

J7

J8

J4

A

B

CT

BA

2345678

K2

K4

K3

K1 K9

K11

K12

K10

K5 K13

K14

K15

K16

TB5

TB6

TB7

TB8

NO

C

NC

NO

C

NC

OUT 9

OUT 10

C

NO

NC

C

NO

NC

OUT 11

OUT 12

NC

C

OUT 13NO

NC

OUT 14NO

C

OUT 16NO

C

OUT 115

NC

C

NO

NC

K6

12

34

56

78

A

B

K1

K2

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

CT

BA

Door 2

1 432

S1 |̂ON

D7

1 2 3 4 5 6

J8

TB2

41

TB1

61

BT1 3VCR/BR2330

S2

J4 J2

+12VDCJ1

1

MS-ICS

RS485

D8 D7 D10 D9 D14 D13 D12 D11

TB18 TB20 TB22 TB24

12V

MS-ACS

MS-I8S

K1

K2

K3

K4

D6

D5

D7

D4

D9

D8

D10

D4

K8

K7

K6

K5

OU

T AO

UT B

OU

T CO

UT D O

UT

EO

UT

FO

UT

GO

UT

H

MS-R8S

MR52

12

34

56

78

J2

TB1

GND

J3

J5

TR-

TR+

VOD0DAT

GND

D1LED

DAT

BZR

TB4

J4

BA

U1J6

TB3

TB2

K2

K1

I1I1I2I2GND

VIN

CNCNOC NONC

K2K1

MR50

Door 1

Door 2

234

1

MR51eDoor 1

234

1

1J2

23

45

67

8

TB1

GND

J3

J5

TR-

TR+

VOD0DAT

GND

D1LED

DAT

BZR

TB4

J4

BA

U1J6

TB3

TB2

K2

K1

I1I1I2I2GND

VIN

CNCNOC NONC

K2K1

Door 1

MR50

Door 1

MR16inMR16out