Page 1: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Moxa’s Managed Switch Next Generation OS User’s Manual

Version 1.0, April 2020

www.moxa.com/product

© 2020 Moxa Inc. All rights reserved.

Models covered by this user's manual: MDS-G4000 Series Managed Ethernet Switches

Page 2: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Moxa’s Managed Switch Next Generation OS User’s Manual

The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement.

Copyright Notice

© 2020 Moxa Inc. All rights reserved.

Trademarks

The MOXA logo is a registered trademark of Moxa Inc. All other trademarks or registered marks in this manual belong to their respective manufacturers.

Disclaimer

Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa.

Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time.

Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.

This product might include unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication.

Technical Support Contact Information

www.moxa.com/support

Moxa Americas Toll-free: 1-888-669-2872 Tel: +1-714-528-6777 Fax: +1-714-528-6778

Moxa China (Shanghai office) Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-21-5258-5505

Moxa Europe Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99

Moxa Asia-Pacific Tel: +886-2-8919-1230 Fax: +886-2-8919-1231

Moxa India Tel: +91-80-4172-9088 Fax: +91-80-4132-1045

Page 3: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Table of Contents

1. About This Manual ............................................................................................................................. 1-1 Symbols for the Meanings in the Web Interface Configurations ................................................................. 1-2 About Note, Attention, and Warning ...................................................................................................... 1-3 Configuration Reminders ..................................................................................................................... 1-4

A: About Mandatory Parameters .................................................................................................... 1-4 B: Configurations before Enable/Disable ......................................................................................... 1-4

2. Getting Started ................................................................................................................................. 2-1 Log in by Web Interface ...................................................................................................................... 2-2

Connecting to the Switch .............................................................................................................. 2-3 Log in by RS-232 Console .................................................................................................................... 2-4 Log in by Telnet .................................................................................................................................. 2-7

3. Web Interface Configuration ............................................................................................................. 3-1 Function Introduction .......................................................................................................................... 3-2 Device Summary ................................................................................................................................ 3-3

Model Information ....................................................................................................................... 3-4 Panel Status ............................................................................................................................... 3-4 Event Summary (Last 3 Days) ...................................................................................................... 3-6 CPU Utilization History ................................................................................................................. 3-7 Top 5 Interface Error Packet ......................................................................................................... 3-7 Top 5 Interface Utilization ............................................................................................................ 3-8

System .............................................................................................................................................. 3-9 System Management ................................................................................................................... 3-9 Account Management................................................................................................................. 3-18 Network ................................................................................................................................... 3-23 Time ........................................................................................................................................ 3-32

Port ................................................................................................................................................ 3-37 Port Interface ........................................................................................................................... 3-38 Link Aggregation ....................................................................................................................... 3-42 PoE ......................................................................................................................................... 3-45

Layer 2 Switching ............................................................................................................................. 3-53 VLAN ....................................................................................................................................... 3-53 MAC ........................................................................................................................................ 3-62 QoS ......................................................................................................................................... 3-64 Multicast .................................................................................................................................. 3-81

Network Redundancy ........................................................................................................................ 3-87 Layer 2 Redundancy .................................................................................................................. 3-88

Management .................................................................................................................................. 3-107 Network Management .............................................................................................................. 3-107

Security ......................................................................................................................................... 3-113 Device Security ....................................................................................................................... 3-114 Network Security ..................................................................................................................... 3-120 Authentication ........................................................................................................................ 3-134 Login Authentication ................................................................................................................ 3-134

Diagnostics .................................................................................................................................... 3-138 System Status ........................................................................................................................ 3-139 Event Notification .................................................................................................................... 3-144 Diagnosis ............................................................................................................................... 3-151

Maintenance and Tool ..................................................................................................................... 3-161 Standard/Advanced Mode ......................................................................................................... 3-161 Disable Auto Save ................................................................................................................... 3-162 Locator .................................................................................................................................. 3-163 Reboot ................................................................................................................................... 3-164 Reset to Default ...................................................................................................................... 3-165 Log Out of the Switch .............................................................................................................. 3-165

A. Account Privileges List ...................................................................................................................... A-1 Account Privileges List ......................................................................................................................... A-2

B. Event Log Description ....................................................................................................................... B-1 Event Log Description ......................................................................................................................... B-2

C. SNMP MIB File ................................................................................................................................... C-1 Standard MIB Installation Order ........................................................................................................... C-2 MIB Tree ........................................................................................................................................... C-3

Page 4: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

1 1. About This Manual

Thank you for purchasing Moxa’s managed switch. Read this user’s manual to learn how to connect your Moxa switch with various interfaces and how to configure all settings and parameters via the user-friendly web interface.

Three methods can be used to connect to the Moxa’s switch, which all will be described in the next two chapters. See the following descriptions for each chapter’s main functions.

Chapter 2: Getting Started In this chapter, we explain the instruction on how to initialize the configuration on Moxa’s switch. We provide three interfaces to access the configuration settings: RS-232 console interface, telnet interface, and web interface.

Chapter 3: Web Interface Configuration

In this chapter, we explain how to access a Moxa switch’s various configuration, monitoring, and management functions. The functions can be accessed by web browser. We describe how to configure the switch functions via web interface, which provides the most user-friendly way to configure a Moxa switch.

Appendix A: Account Privileges List

This appendix describes the read/write access privileges for different accounts on Moxa’s Managed Ethernet Series switch.

Appendix B: Event Log Description

In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix helps users quickly check the detailed definition for each event.

Appendix C: SNMP MIB File

This appendix contains the SNMP MIB files so that users can manage the entities in a network with Moxa’s switch.

Page 5: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS About This Manual

1-2

Symbols for the Meanings in the Web Interface Configurations

The Web Interface Configuration includes various symbols. For your convenience, refer to the following table for the meanings of the symbols.

Symbols Meanings

Add

Read detailed information

Clear all

Column selection

Refresh

Enable/Disable Auto Save When Auto Save is disabled, users need to click this icon to save the configurations.

Export*

Edit

Re-authentication

Delete

Panel View

Expand

Collapse

Hint Information

Settings

Data Comparison

Menu icon

Change mode

Locator

Reboot

Reset to default

Logout

Increase

Page 6: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS About This Manual

1-3

Symbols Meanings

Decrease

Equal

Menu

Search

*The Export function helps users save the current configurations or information for the specific functions. It is located on the upper part of the configuration area. There are two formats available: CVS, or PDF. Select the format and save in your local computer.

About Note, Attention, and Warning Throughout the whole manual, users will see some notes, attentions, and warnings. Here are the explanations for each definition.

Note: It indicates the additional explanations for the situation that users might encounter. Here is the example:

NOTE By default, the password assigned to the Moxa switch is moxa. Be sure to change the default password after you first log in to help keep your system secure.

Attention: It indicates the situations where users might take some extra care or it might bring some problems. Here is the example:

ATTENTION

When a different type of module has been inserted into the switch, we suggest you configure the settings, or use reset-to-default.

Warning: It indicates the situations where users need to pay particular attention to, or it might bring serious damage to the system or the switch. Here is an example:

WARNING

There is a risk of explosion if the battery is replaced by an incorrect type.

Page 7: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS About This Manual

1-4

Configuration Reminders In this section, several examples will be used to remind users when configuring the settings for Moxa’s switch.

A: About Mandatory Parameters

1. The items with asterisks mean they are mandatory parameters that must be provided. In the figure above, the parameters for VLAN, Version, and Query Interval all need to be provided, or it will not be created or applied.

2. If the item is marked with red it means this item has been skipped. You need to fill in the parameters or you cannot apply or create the function.

In addition, some parameter values will be limited to a specific range. If the values exceed the range, it cannot be applied or created.

B: Configurations before Enable/Disable In another situation, some settings can be configured first, but remain disabled. Users can decide to enable them when necessary without configuring the same settings again. This is particularly convenient and user-friendly when configuring various settings. For example, in Spanning Tree configuration page, users can configure the Guard settings first, but later select to disable the Guard settings in the General tab. When users decide to enable the Guard settings, they only need to select Enable in General settings, so that the Guard setting can be enabled at the same time.

Page 8: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

2 2. Getting Started

In this chapter, we explain how to log in a Moxa’s switch for the first time. There are three ways to access the Moxa switch’s configuration settings: RS-232 console, or web-based interface.

The following topics are covered in this chapter:

Log in by Web Interface

Connecting to the Switch

Log in by RS-232 Console

Log in by Telnet

Page 9: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Getting Started

2-2

Log in by Web Interface You can directly connect Moxa’s switch to your computer with a standard network cable or install your computer at the same intranet as your switch. Then you need to configure your computer’s network setting. The default IP address for the Moxa’s switch is:

192.168.127.253

For example, you can configure the computer’s IP setting as 192.168.127.99, and the subnet mask as 255.255.255.0.

Click OK when finished.

Page 10: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Getting Started

2-3

Connecting to the Switch Open a browser, such as Google Chrome, Internet Explorer 11, or Firefox, and connect to the following IP address:

http://192.168.127.253

The default username and password are:

Username: admin

Password: moxa

Click Login to continue. If you have logged in before, you will see a screen indicating the previous login information. Click Close.

Another system message will appear, reminding you to change the default password. We recommend you change your password, or a message will appear whenever you log in. You can change the password in the Account Management section. Click Close to continue.

Page 11: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Getting Started

2-4

Log in by RS-232 Console The Moxa’s managed switch offers a serial console port, allowing users to connect to the switch and configure the settings. Do the following steps for the serial connection and configuration.

1. Prepare an RS-232 serial cable with an RJ45 interface.

2. Connect the RJ45 interface end to the console port on the switch, and the other end to the computer.

3. We recommend you use PComm Terminal Emulator for serial communication. The software can be downloaded free of charge from Moxa’s website.

After installing PComm Terminal Emulator, open the Moxa switch’s console as follows:

1. From the Windows desktop, click Start Moxa PComm Terminal Emulator.

2. Select Open under the Port Manager menu to open a new connection.

Page 12: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Getting Started

2-5

3. The Property window should open. On the Communication Parameter tab for Ports, select the COM port that is being used for the console connection. Set the other fields as follows: 115200 for Baud Rate, 8 for Data Bits, None for Parity, and 1 for Stop Bits.

4. On the Terminal tab, select VT100 for Terminal Type, and then click OK to continue.

Page 13: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Getting Started

2-6

5. The console will prompt you to log in. The default login name is admin, and the default password is moxa. This password will be required to access any of the consoles (web, serial, Telnet).

6. After successfully connecting to the switch by serial console, users can start configuring the switch parameters by using command line instructions. Refer to the Moxa Command Line Interface Manual.

NOTE By default, the password assigned to the Moxa switch is moxa. Be sure to change the default password after you first log in to help keep your system secure.

Page 14: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Getting Started

2-7

Log in by Telnet Opening the Moxa switch’s Telnet or web console over a network requires that the PC host and Moxa switch are on the same logical subnet. You might need to adjust your PC host’s IP address and subnet mask. By default, the Moxa switch’s IP address is 192.168.127.253 and the Moxa switch’s subnet mask is 255.255.255.0. Your PC’s IP address must be set to 192.168.xxx.xxx if the subnet mask is 255.255.0.0, or to 192.168.127.xxx if the subnet mask is 255.255.255.0.

NOTE When connecting to the Moxa switch’s Telnet or web console, first connect one of the Moxa switch’s Ethernet ports to your Ethernet LAN, or directly to your PC’s Ethernet port. You can use either a straight-through or cross-over Ethernet cable.

NOTE The Moxa switch’s default IP address is 192.168.127.253.

After making sure that the Moxa switch is connected to the same LAN and logical subnet as your PC, open the Moxa switch’s Telnet console as follows:

1. Click Start Run from the Windows Start menu and then Telnet to the Moxa switch’s IP address from the Windows Run window. You can also issue the Telnet command from a DOS prompt.

Page 15: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Getting Started

2-8

2. Next, use Telnet to connect the Moxa switch’s IP address (192.168.127.253) from the Windows Run window. You can also issue the Telnet command from a DOS prompt.

3. The Telnet console will prompt you to log in. The default login name is admin, and the password is moxa. This password will be required to access any of the consoles (web, serial, Telnet).

4. After successfully connecting to the switch by Telnet, users can start configuring the switch parameters by using command line instructions. Refer to the Moxa Command Line Interface Manual.

NOTE By default, the password assigned to the Moxa switch is moxa. Be sure to change the default password after you first log in to help keep your system secure.

Page 16: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

3 3. Web Interface Configuration

Moxa’s managed switch offers a user-friendly web interface for easy configurations. Users find it simple to configure various settings over the web interface. All configurations for the Moxa’s managed switch can be easily set up and done via this web interface, essentially reducing system maintenance and configuration effort.

The following topics are covered in this chapter:

Function Introduction

Device Summary

Model Information

Panel Status

Event Summary (Last 3 Days)

CPU Utilization History

Top 5 Interface Error Packet

Top 5 Interface Utilization

System

System Management

Account Management

Network

Time

Port

Port Interface

Link Aggregation

PoE

Layer 2 Switching

VLAN

MAC

QoS

Multicast

Network Redundancy

Layer 2 Redundancy

Management

Network Management

Security

Device Security

Network Security

Authentication

Login Authentication

Diagnostics

System Status

Event Notification

Diagnosis

Maintenance and Tool

Standard/Advanced Mode

Disable Auto Save

Locator

Reboot

Reset to Default

Log Out of the Switch

Page 17: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-2

Function Introduction This section describes the web interface design, providing a basic visual concept for users to understand the main information or configuration menu for the web interface pages.

1. Login Name: It shows the role of the login name.

2. Configuration Mode: Two modes can be shown: Standard Mode and Advanced Mode.

• Standard Mode: Some of the features and parameters will be hidden to make the configurations simpler (default).

• Advanced Mode: More features and parameters will be shown for users to configure detailed settings.

3. Search Bar: Type the items you want to search of the function menu tree.

4. Function Menu: All functions of the switch are shown here. Click the function you want to view or configure.

5. Device Summary: All important device information of the functions will be shown here.

Page 18: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-3

Device Summary After successfully connecting to the switch, the Device Summary will automatically appear. You can view the whole web interface on the screen. If you are in the middle of performing configurations, simply click Device Summary on the Function Menu and you can view the detailed information of the switch.

See the following sections for detailed descriptions for the specific items.

Page 19: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-4

Model Information This shows the model information, including product model name, serial number, firmware version, system uptime, etc.

Panel Status This section illustrates the panel status. For example, the connecting ports will be shown in green, while the disconnected ports will be shown in gray. Click Expand to view more detailed information on the panel status and click Collapse to return.

Click Expand to view more detailed information on the panel status and click Collapse to return.

Page 20: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-5

Panel View

By clicking this icon, u , users can view the device port status by a graphic figure. Click the close icon on the upper right corner to return to the main page.

This panel view figure might vary, depending on the different modules that you purchase.

Page 21: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-6

Event Summary (Last 3 Days) This section shows the event summary for the past three days.

Click View All Event Logs to go to the Event Log page, where you can view all event logs.

For Event Log settings, refer to Event Log under the Diagnosis section.

Page 22: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-7

CPU Utilization History This section shows the CPU usage. The data will be shown as a percentage over time. Click the refresh icon on the page to show the latest information.

Top 5 Interface Error Packet If any error packets occur, top 5 error packets will be shown here. Click the refresh icon on the page to show the latest information.

Page 23: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-8

Top 5 Interface Utilization The top 5 interface utilizations will be shown here. Click the refresh icon on the page to show the latest information.

Page 24: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-9

System Click System on the function menu. You can configure the System Management, Account Management, Network, and Time configurations.

System Management Click System Management, four functions can be configured under this section: Information Setting, Firmware Upgrade, Configure Backup and Restore, and Event Log Backup.

Page 25: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-10

Information Setting

Define Information Setting items to make it easier to identify different switches that are connected to your network.

Device Name

Setting Description Factory Default 1 to 255 characters This option is useful for differentiating between the roles or

applications of different units. Note that the device name cannot be empty.

moxa

NOTE The Device Name field follows the PROFINET I/O naming rule. The name can only include the following characters, a-z/0-9/-. The prefix cannot start from port-x where x=0~9.

Location

Setting Description Factory Default Max. 255 characters This option is for differentiating between the locations of

different switches. Example: production line 1. None

Description

Setting Description Factory Default

Max. 255 characters This option is for recording a more detailed description of the unit.

None

Contact Information

Setting Description Factory Default Max. 255 characters Users can input contact information such as email address, or

telephone number when problems occur. None

When finished, click Apply to save your changes.

Page 26: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-11

Firmware Upgrade

There are three ways to update your Moxa switch’s firmware: from a local *.rom file, by remote SFTP server, and remote TFTP server.

Local Select Local tab.

Select File

Before performing firmware upgrade, download the updated firmware (*.rom) file first from Moxa’s website (www.moxa.com).

Setting Description Factory Default Select the firmware file Select the firmware file from the location where the updated

firmware is located. None

Browse for the (*.rom) file, and then click the Upgrade button.

This option allows users to select the updated firmware file and perform the firmware upgrade.

None

SFTP Select SFTP tab.

Server IP Address

Setting Description Factory Default Input the IP address of the SFTP server.

Input the server IP address of the computer where the new firmware file (*.rom) is located.

None

Page 27: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-12

Account

Setting Description Factory Default Input the account of the SFTP server

The account must be authorized in order for the SFTP Server to have a secure connection.

None

Password

Setting Description Factory Default Input the password for the SFTP server

The account has to be specified in order to authorize the SFTP Server for secure connection.

None

File Name

Setting Description Factory Default

Input the file name of the firmware

Input the file name of the new firmware. None

When finished, click Upgrade to perform the firmware upgrade. The switch will reboot automatically and perform the firmware upgrade.

TFTP Server Users can also upgrade firmware via the TFTP server. Click TFTP tab first.

Server IP Address

Setting Description Factory Default Input the IP address of the TFTP server

Input the IP address of the TFTP server where the new firmware file (*.rom) is located.

None

File Name

Setting Description Factory Default

Input the file name of the firmware

Input the file name of the new firmware. None

When finished, click Upgrade to perform the firmware upgrade.

Page 28: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-13

Configuration Backup and Restore

There are three ways to back up and restore your Moxa switch’s configuration: from a local configuration file, by remote SFTP server, or by remote TFTP server. In addition, file encryption is also provided for your safety concern.

Local

Click Local tab first.

Configuration Selection

Setting Description Factory Default Running Configuration Back up the running configuration. Running

Configuration Startup Configuration Back up the start-up configuration.

Default Configuration

Setting Description Factory Default

Not Included Back up the configuration without default settings. Not Included

Included Back up the configuration with default settings.

Select File

Setting Description Factory Default Click the Backup button to back up the configuration file to a local drive.

Back up the system file to your local computer. None

Browse for a configuration file on a local disk, and then click the Restore button.

Select the configuration file and perform system restoration. None

Page 29: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-14

SFTP Server Click SFTP tab first.

Server IP Address

Setting Description Factory Default Input the IP address of the SFTP server

Input the IP address of the SFTP server where the new firmware file (*.rom) is located.

None

Account

Setting Description Factory Default

Input the account of the SFTP server

An account must be provided to authorize the SFTP server for secure connection.

None

Password

Setting Description Factory Default Input the passwords for the SFTP server

The password has to be specified in order to authorize the SFTP Server for secure connection.

None

File Name

Setting Description Factory Default Input the backup/restore file name (support up to 54 characters, including the .ini file extension).

Input the file name of the configuration backup or restoration file.

None

When finished, click Backup or Restore to back up or restore the system configuration file.

Page 30: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-15

TFTP Server

Click TFTP tab first.

Server IP Address

Setting Description Factory Default Input the IP address of the TFTP server

Users can input the IP address of the TFTP server. None

File Name

Setting Description Factory Default Input the backup/restore file name (supports up to 54 characters, including the .ini file extension).

Users can input the file name to back up or restore the system configuration file.

None

When finished, click Backup or Restore to perform the firmware upgrade.

File Encryption

To encrypt the configuration file, click the File Encryption tab first.

Enable Configuration File Encryption

Setting Description Factory Default

Enabled Enable the configuration file to be encrypted. Disabled

Disabled Disable the feature that allows the configuration file to be encrypted.

Page 31: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-16

Password

Setting Description Factory Default 4 to 16 characters, numbers only.

Input the password when users encrypt the configuration file. None

When finished, click Apply to save your changes.

Event Log Backup

There are three ways to back up Moxa switch’s log files: from a local drive, by remote SFTP server, or by remote TFTP.

Local

Click Local tab.

Click Backup to back up the log file to a local drive.

SFTP Server

Click SFTP tab.

Server IP Address

Setting Description Factory Default Input the IP address of the SFTP server

Users can input the IP address of the SFTP server. None

Page 32: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-17

Port

Setting Description Factory Default Input the port of the SFTP server, 1 to 65535

Specify the port used in the SFTP server. None

Account

Setting Description Factory Default Input the account of the SFTP server

An account must be specified to authorize the SFTP server for secure connection.

None

Password

Setting Description Factory Default

Input the password for the SFTP server

The password has to be entered in order to authorize the SFTP Server for secure connection.

None

File Name

Setting Description Factory Default Input the file name for event log backup

Users can input the file name of the event log. None

When finished, click Backup to back up the event log file.

TFTP Server

Click TFTP tab.

Server IP Address

Setting Description Factory Default Input the IP address of the TFTP server

Users can input the IP address of the TFTP server. None

Port

Setting Description Factory Default

Input the port of the TFTP server, 1 to 65535

Users can input the port used in the TFTP server. None

File Name

Setting Description Factory Default Input the file name for event log backup

Users can input the file name of the event log. None

When finished, click Backup to back up the event log file.

Page 33: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-18

Account Management The Account Management feature allows users to manage the accounts of the switch. You can enable different accounts with different roles to facilitate convenient management and safe access.

User Account

This section describes how to manage the existing accounts of the switch. Here, you can add, edit, and delete user accounts for the switch. By default, there is only one account: admin. In order to enhance security, we suggest you create a new account with the user authority.

There is a search function on the upper right of the User Account page. Type the username you want to search for.

Page 34: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-19

Editing Existing Accounts

Select the account you want to edit and click the edit icon.

Configure the following settings.

Enabled

Setting Description Factory Default Enabled This enables the user account. Enabled

Disabled This disables the user account.

Authority

Setting Description Factory Default

admin This account has read/write access for all configuration parameters.

admin

supervisor This account has read/write access for some specific configuration parameters.

user This account can only view some specific configuration parameters.

Page 35: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-20

New Password

Setting Description Factory Default 4 to 63 characters Enter the password to use for this account. None

Confirm Password

Setting Description Factory Default 4 to 63 characters Reenter the password to confirm it. None

Email

Setting Description Factory Default

Input an email address Input an email address for the account if required. None

When finished, click Apply to save your changes.

NOTE Refer to Appendix A for detailed descriptions for read/write access privileges for the admin, supervisor, and user authority levels.

Creating a New Account

You can create new account by clicking the + icon on the configuration page.

Page 36: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-21

Configure the following settings.

Enabled

Setting Description Factory Default Enabled This enables the account. Enabled

Disabled This disables the account.

Username

Setting Description Factory Default

Input a username, 4 to 32 characters

Input a new username for this account. None

Authority

Setting Description Factory Default admin This account has read/write access of all configuration

parameters. None

supervisor This account has read/write access for some specific configuration parameters.

user This account can only view some specific configuration parameters.

In order to enhance security, we suggest you create a new account with the user authority.

New Password

Setting Description Factory Default 4 to 63 characters Input a new password for this account. None

Confirm Password

Setting Description Factory Default 4 to 63 characters Reenter the password to confirm. None

Email

Setting Description Factory Default

Input an email address Input an email address for the account if required. None

When finished, click Create to complete.

Page 37: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-22

Delete an Existing Account

To delete the existing account, simply select the account you want to delete, and then click the delete icon on the configuration page.

Click Delete to delete the account.

Password Policy

In order to prevent hackers from cracking weak passwords, a password policy can be set. The password policy can force users to create passwords with a minimum length and complexity, and can also set a maximum lifetime for the password to ensure it is changed periodically.

Page 38: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-23

Minimum Length

Setting Description Factory Default Input from 4 to 63 This sets the minimum length of the password. 4

Password Complexity Strength Check

Setting Description Factory Default digit, letter cases, special characters

These determine the required complexity for the password. Multiple options may be checked.

None

Password Max-life-time (day)

Setting Description Factory Default

Input from 0 to 365 This determines how long the password can be used before it must be changed.

0

When finished, click Apply to save your changes.

Network This section describes how to configure the switch’s network settings, including IP Configuration and the DHCP Server.

IP Configuration

Users can configure the IP settings of the switch.

Page 39: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-24

Get IP From

Setting Description Factory Default Manual The IP address of the switch must be set manually. Manual

DHCP The IP address of the switch will be assigned automatically by the network’s DHCP server.

IP Address

Setting Description Factory Default

Input the IP address for the switch

Specify the IP address to use for the switch. 192.168.127.253

Subnet Mask

Setting Description Factory Default Input the subnet mask for the switch

Specify the subnet mask to use for the switch. 24(255.255.255.0)

Default Gateway

Setting Description Factory Default Input the IP address for the gateway

Specify the IP address of the gateway that connects the LAN to a WAN or another network.

None

DNS Server 1

Setting Description Factory Default

Input the IP address of the 1st DNS server

Specify the IP address of the 1st DNS server used by your network. After specifying the DNS server’s IP address, you can use the switch’s URL (e.g., www.mymoxaswitch.com) to open the web console instead of entering the IP address.

None

DNS Server 2

Setting Description Factory Default Input the IP address of the 2nd DNS server

Specify the IP address of the 2nd DNS server used by your network. The switch will use the secondary DNS server if the first DNS server fails to connect.

None

IPv6 Global Unicast Address Prefix (Prefix Length: 64 bits) Default Gateway

Setting Description Factory Default Global Unicast Address Prefix

The prefix value must be formatted according to the RFC 2373 IPv6 Addressing Architecture, using 8 colon-separated 16-bit hexadecimal values. One double colon can be used in the address to indicate the appropriate number of zeros required to fill the undefined fields. Note: This feature is only available in Advanced Mode.

None

IPv6 DNS Server 1

Setting Description Factory Default

Input the IPv6 IP address of the 1st DNS server

Specify the IPv6 address of the 1st DNS server used by your network. After specifying the DNS server’s IP address, you can use the switch’s URL (e.g., www.mymoxaswitch.com) to open the web console instead of entering the IP address. Note: This feature is only available in Advanced Mode.

None

IPv6 DNS Server 2

Setting Description Factory Default Input the IPv6 address of the 2nd DNS server

Specify the IPv6 address of the 2nd DNS server used by your network. The Moxa switch will use the secondary DNS server if the first DNS server fails to connect. Note: This feature is only available in Advanced Mode.

None

Page 40: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-25

IPv6 Global Unicast Address

Setting Description Factory Default None Displays the IPv6 Global Unicast address. The network portion

of the Global Unicast address can be configured by specifying the Global Unicast Prefix and using an EUI-64 interface ID in the low order 64 bits of the address. The host portion of the Global Unicast address is automatically generated using the modified EUI-64 form of the interface identifier (the switch’s MAC address). Note: This feature is only available in Advanced Mode.

None

IPv6 Link-Local Address

Setting Description Factory Default None The network portion of the Link-Local address is FE80 and the

host portion of the Link-Local address is automatically generated using the modified EUI-64 form of the interface identifier (the switch’s MAC address). Note: This feature is only available in Advanced Mode.

None

When finished, click Apply to save your changes.

DHCP Server

This section describes how to configure the DHCP server settings for Moxa’s switch. First, click the General tab.

Then select DHCP / MAC-based IP Assignment, and click Apply.

DHCP

Select the DHCP tab and then click the + icon on the configuration page to create a new DHCP server pool.

Page 41: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-26

Configure the following parameters.

NOTE Users can only create one IP pool. It can be connected to different network subnets with the Management IP of the switch.

Enable

Setting Description Factory Default Enabled Enables the DHCP server pool. Enabled

Disable Disables the DHCP server pool.

Start IP Address

Setting Description Factory Default

Input the first IP address

Specify the first IP address for the pool. None

Subnet Mask

Setting Description Factory Default Select from the drop-down list

Specify the subnet mask for the pool. None

End IP Address

Setting Description Factory Default Input the last IP address

Specify the last IP address for the pool. None

Default Gateway

Setting Description Factory Default

Input the IP address of the default gateway

Specify the default gateway for clients to use. None

Page 42: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-27

Lease Time (sec.)

Setting Description Factory Default Input the lease time for the DHCP, from 10 to 604,800 seconds (up to 7 days)

Specify the lease time for DHCP IP assignments. 86400

DNS Server 1

Setting Description Factory Default Input the IP address of the 1st DNS server

Specify the IP address of the 1st DNS server for clients to use. None

DNS Server 2

Setting Description Factory Default

Input the IP address of the 2nd DNS server

Specify the IP address of the 2nd DNS server for clients to use. None

NTP Server

Setting Description Factory Default Input the address of the NTP server

Specify the NTP server clients will use. None

When finished, click Create.

MAC-based IP Assignment

Users can assign an IP address for a specific MAC address. This can be useful if you always want the same IP address to be assigned to a specific device, even if it is reconnected or connected to a different port.

Click the MAC-based IP Assignment tab, and then click the + icon on the configuration page.

Page 43: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-28

Configure the following parameters.

Enable

Setting Description Factory Default Enabled Enables the MAC-based IP assignment entry. Enabled

Disabled Disables the MAC-based IP assignment entry.

Hostname

Setting Description Factory Default

Enter a hostname between 0 and 63 characters

Specify a hostname to use for the DHCP client. None

IP Address

Setting Description Factory Default Input the assigned IP address

Specify the IP address to assign to the client. None

Subnet Mask

Setting Description Factory Default Select from the drop-down list

Specify the subnet mask to use for the client. None

MAC Address

Setting Description Factory Default

Input the assigned MAC address

Specify the MAC address of the device you want to assign an IP address to. Make sure the MAC address is entered in the correct format. Here is an example: 28-d2-44-D3-e3-f2 or 28:d2:44:D3:e3:f2.

None

Page 44: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-29

Default Gateway

Setting Description Factory Default Input the IP address of the default gateway

Specify the default gateway for the client to use. None

Lease Time (sec.)

Setting Description Factory Default Input the lease time for the DHCP, from 10 to 604800.

Define how long before the IP address needs to be reassigned.

86400

DNS Server 1

Setting Description Factory Default

Input the IP address of the 1st DNS server

Specify the IP address of the 1st DNS server for the client to use.

None

DNS Server 2

Setting Description Factory Default Input the IP address of the 2nd DNS server

Specify the IP address of the 2nd DNS server for the client to use.

None

NTP Server

Setting Description Factory Default Input the address of the NTP server

Specify the NTP server the client will use. None

When finished, click Create.

Port-based IP Assignment

Users can assign an IP to a device based on what switch port it is connected to. This can be useful if you want to always use the same IP for a device connected to a specific port, even if it is replaced with a different device.

On the General tab, select Port-based IP Assignment. Click Apply.

Next, click the Port-based IP Assignment tab, and then click the + icon on the configuration page.

Page 45: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-30

Configure the following parameters.

Enable

Setting Description Factory Default Enabled Enables the port-based IP assignment entry. Enabled

Disabled Disables the port-based IP assignment entry.

Port

Setting Description Factory Default

Select from 1 to 28 Select which switch port the DHCP server will assign an IP address for.

None

IP Address

Setting Description Factory Default Input the assigned IP address

Specify the IP address to assign to the client. None

Subnet Mask

Setting Description Factory Default Select from the drop-down list

Specify the subnet mask to use for the client. None

Default Gateway

Setting Description Factory Default

Input the IP address of the default gateway

Specify the default gateway for the client to use. None

Page 46: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-31

Lease Time (sec.)

Setting Description Factory Default Input the lease time for the DHCP, from 10 to 604800

Define how long before the IP address needs to be reassigned. 86400

DNS Server 1

Setting Description Factory Default Input the IP address of the 1st DNS server

Specify the IP address of the 1st DNS server for the client to use.

None

DNS Server 2

Setting Description Factory Default

Input the IP address of the 2nd DNS server

Specify the IP address of the 2nd DNS server for the client to use.

None

NTP Server

Setting Description Factory Default Input the address of the NTP server

Specify the NTP server the client will use. None

When finished, click Create.

Lease Table

Click Lease Table to view detailed information for the hostname, IP address, MAC address, and time left for each port.

Item Description Hostname The hostname of the client.

IP Address The IP address of the client.

MAC Address The MAC address of the client.

Time Left The amount of time left on the DHCP lease for the client.

Page 47: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-32

Time This section describes how to configure the Time Zone and System Time settings for the switch. The switch has a time calibration function based on information from an NTP server or a user-specified time and date, allowing functions such as automatic warning emails to include a time and date stamp.

NOTE The user must update the Current Time and Current Date after the switch has been powered off for an extended period of time (e.g., three days). The user must pay particular attention to this when there is no NTP server or Internet connection available.

Time Zone

Users can configure the time zone for the switch.

System Uptime

Setting Description Factory Default System-specified time This indicates how long the switch has been running since the

last cold start. N/A

Current Time

Setting Description Factory Default User-specified time Shows the current system time. None

Page 48: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-33

Time Zone

Setting Description Factory Default Select from the drop-down list

Specify the time zone to use for the switch. GMT (Greenwich Mean Time)

Daylight Saving Time

The Daylight Saving Time settings are used to automatically adjust the time according to regional standards.

Configure the following settings.

Daylight Saving Time

Setting Description Factory Default Enabled Enables Daylight Saving Time. Disabled

Disabled Disables Daylight Saving Time.

Start Date

Setting Description Factory Default User-specified date Specify the date that Daylight Saving Time begins. None

End Date

Setting Description Factory Default User-specified date Specify the date that Daylight Saving Time ends. None

Offset

Setting Description Factory Default

User-specified hour Specify the offset (in HH:MM format) to use during Daylight Saving Time.

None

When finished, click Apply to activate the time zone settings.

System Time

This section describes how to configure the time, NTP server, and NTP authentication settings.

Time

The section describes how to configure the system time. Click the Time tab.

Page 49: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-34

Current Time

Setting Description Factory Default None This automatically shows the current time according to your

default settings. Local

Clock Source

Setting Description Factory Default Select from the drop-down list

Specify whether to set the time manually (Local), from an SNTP server, or from an NTP server.

Local

Clock Source is from Local

Date

Setting Description Factory Default

Select the date Select the current date.

Local

Time

Setting Description Factory Default Input the current time Specify the current time. You can manually input the time, or

you can click Sync From Browser to set the time based on the time used by your web browser.

None

Page 50: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-35

Clock Source is from SNTP

Time Server 1

Setting Description Factory Default Input the address of the 1st SNTP time server

Specify the IP or domain address of the 1st SNTP server to use (e.g., 192.168.1.1, time.stdtime.gov.tw, or time.nist.gov).

Time.nist.gov

Time Server 2

Setting Description Factory Default Input the address of the 2nd SNTP time server

Specify the IP or domain address of the secondary SNTP server to use if the first SNTP server fails to connect.

None

Click Apply to complete.

Clock Source is from NTP If the switch is connecting to an NTP server that requires authentication, refer to the NTP Authentication section to configure the NTP key to use.

Time Server 1

Setting Description Factory Default Input the address of the 1st NTP time server

Specify the IP or domain address of the 1st NTP server to use (e.g., 192.168.1.1, time.stdtime.gov.tw, or time.nist.gov).

Time.nist.gov

Authentication

Setting Description Factory Default Disabled Enable or disable NTP authentication for Time Server 1. Disabled

Time Server 2

Setting Description Factory Default

Input the address of the 2nd time server

Specify the IP or domain address of the secondary NTP server to use if the first NTP server fails to connect.

None

Authentication

Setting Description Factory Default Disabled Enable or disable NTP Authentication for Time Server 2. Disabled

Click Apply to complete.

Page 51: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-36

NTP Server

Click the NTP Server Tab to perform further configuration.

Enable

Setting Description Factory Default Enabled Enable the NTP server. Disabled

Disabled Disable the NTP server.

Client Authentication

Setting Description Factory Default

Enabled Enable NTP authentication. Disabled

Disabled Disable NTP authentication.

When finished, click Apply to save your changes.

NTP Authentication

This section describes how to configure NTP Authentication. Click the NTP Authentication tab, and then click the + icon on the page.

Page 52: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-37

Configure the following settings.

Key ID

Setting Description Factory Default Input the Key ID from 1 to 10

Input the Key ID to use for NTP authentication. None

Type

Setting Description Factory Default Input the authentication type

Input the authentication type. MD5

Key String

Setting Description Factory Default

Input the key string for authentication, from 0 to 32 characters.

Input the password to use for the authentication key. None

When finished, click Create.

Port This section describes how to configure the Port Interface, Link Aggregation, and PoE functions for the switch.

Page 53: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-38

Port Interface Two functions are included in this section: Port Setting and Linkup Delay.

Port Setting

Under Port Setting, select the Setting tab and then click the edit icon on the port you want to configure.

Page 54: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-39

Configure the following parameters.

Admin Status

Setting Description Factory Default Enable Allows data transmission through this port. Enabled

Disabled Disables data transmission through this port.

Media Type

Setting Description Factory Default

Media type Displays the media type for each module’s port. 1000TX,RJ45,PTP

Description

Setting Description Factory Default Max. 63 characters Specify an alias for the port to help differentiate between

different ports (e.g., PLC1). None

Speed/Duplex

Setting Description Factory Default Auto Allows the port to use the IEEE 802.3u protocol to negotiate

with connected devices. The port and connected devices will determine the best speed for that connection.

Auto

10M Half Choose a fixed speed option if the connected Ethernet device has trouble auto-negotiating line speed. 10M Full

100M Half

100M Full

1G Full

Page 55: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-40

Flow Control

This setting enables or disables flow control for the port when the port’s speed is set to Auto. The final result will be determined by the Auto process between the switch and connected devices.

Setting Description Factory Default Enable Enables flow control for this port when the port’s speed is set to

Auto. Disabled

Disable Disables flow control for this port when the port’s speed is set to Auto.

MDI/MDIX

Setting Description Factory Default

Auto Allows the port to auto-detect the port type of the connected Ethernet device, and changes the port type accordingly.

Auto

MDI Choose MDI or MDIX if the connected Ethernet device has trouble auto-detecting the port type. MDIX

Copy Config to Ports

Setting Description Factory Default

Select the port(s) from the drop-down list

Allows you to copy the configuration to other port(s). None

When finished, click Apply to save your changes.

Port Status

To view the status of the ports, click the Status tab.

Page 56: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-41

Linkup Delay

Linkup Delay Overview

Linkup delay is used to prevent a port alternating between link up and link down. It is also sometimes called link flap prevention. This feature is useful when the link connection is unstable. An unstable connection might be caused by a faulty cable, faulty fiber transceiver, duplex mismatch, etc. This feature helps administrators to mitigate the risk of an unstable network, particularly when the topology changes frequently.

Linkup Delay Settings

This section describes how to configure the linkup delay for the ports. Click the Linkup Delay menu. The default value is disabled, which means linkup delay is disabled for all ports.

Enable

Setting Description Factory Default Enable Enables linkup delay. Disabled

Disabled Disables linkup delay.

When finished, click Apply to save your changes.

To configure linkup delay for a port, click the edit icon on the port you want to configure.

Page 57: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-42

Some parameters need to be configured.

Linkup Delay

Setting Description Factory Default Enable Enables linkup delay for the port. Disabled

Disable Disables linkup delay for the port.

Delay Time (sec.)

Setting Description Factory Default

1 to 1000 Specify the linkup delay time from 1 to 1000 seconds. 2

Copy Config to Ports

Setting Description Factory Default Select the port(s) from the drop-down list

Allows you to copy the configurations to other port(s). None

When finished, click Apply to save your changes.

Link Aggregation

Link Aggregation (Port Channel) Overview

Link Aggregation helps balance, optimize, and facilitate the switch’s throughput. This method can combine multiple network communications in parallel to maximize data throughput, increasing data communication efficiency for each port. In addition, it also acts as a useful method for network redundancy when a link fails. In general, Link Aggregation supports combining multiple physical switch ports into a single, efficient bandwidth data communication route. This can improve network load sharing and increase network reliability.

Static Trunk

For some networking applications, a situation can arise where traffic from multiple ports is required to be filtered through one port. For example, if there are 30 UHD IP surveillance cameras deployed and connected in a ring, the traffic can reach up to 1 Gbps, causing a surge in traffic that can increase network loading by up to 50%. Hence, the uplink port needs to use the static trunk function to provide more bandwidth and redundancy protection.

LACP

The Link Aggregation Control Protocol (LACP) allows a network device to negotiate an automatic bundling of several ports by sending LACP packets to the peer, a directly connected device that also uses LACP.

Page 58: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-43

Algorithm

In Link Aggregation, three load-sharing hash algorithms can be used: SMAC, DMAC, and SMAC + DMAC.

SMAC: SMAC stands for Source MAC, often used as a tool to optimize algorithm parameters. It is also an algorithm to evaluate the most efficient network data communication. SMAC is used for many different client situations.

DMAC: DMAC stands for Destination MAC. The packets will be distributed and transmitted to the destination MAC address hash algorithm, and is usually used in many different destination servers situation.

SMAC + DMAC: This can be used for more complex hash algorithm, but where the network just has a few clients and servers.

Link Aggregation Settings

This section describes how to configure link aggregation for each port. Click Link Aggregation on the menu and then click the + icon on the configuration page.

To create a link aggregation group, configure the following parameters.

LA Group Status

Setting Description Factory Default Enable Enable link aggregation grouping. None

Disable Disable link aggregation grouping.

Page 59: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-44

Type

Setting Description Factory Default Manual Configure the link aggregation type manually. None

LACP Configure the link aggregation type by LACP.

Config Member Port

Setting Description Factory Default

Select from the ports Select the ports you want to create for link aggregation grouping.

None

Algorithm (in Advanced Mode only)

Setting Description Factory Default SMAC Use SMAC as algorithm configuration. SMAC + DMAC

DMAC Use DMAC as the algorithm configuration.

SMAC + DMAC Use both SMAC and DMAC as the algorithm configuration.

When finished, click Create to continue.

You can view the current Link Aggregation or Port Channel (Trunk) status on the configuration page. You can also edit or delete by clicking the edit or delete icon on the page.

Editing Port Setting for Link Aggregation

To edit each port’s setting for Link Aggregation, click the edit icon on the port name. You can also check the port and then click the edit icon for editing the port settings for Link Aggregation.

Edit the following port settings.

Page 60: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-45

LA Group Status

Setting Description Factory Default Enable Enable link aggregation grouping. None

Disable Disable link aggregation grouping.

Type

Setting Description Factory Default

Manual Configure link aggregation manually. None

LACP Configure link aggregation by LACP.

Config Member Port

Setting Description Factory Default Select from the ports Select the ports you want to create link aggregation grouping

for. None

When finished, click Apply to save your changes.

Deleting the Port for Link Aggregation

To delete the port for Link Aggregation, check the port and then click the delete icon.

Click Delete to finish. Note that some features, such as RSTP and VLAN will be set to default values once you delete the Link Aggregation setting.

PoE

PoE Overview

Power over Ethernet (PoE) has become increasingly popular, due in large part to the reliability provided by PoE Ethernet switches that supply the power to Powered Devices (PD) when AC power is not available or is too expensive to provide locally.

Power over Ethernet can be used with the following types of devices:

• Surveillance cameras • Security I/O sensors • Industrial wireless access points • Emergency IP phones

Page 61: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-46

Recently, more data, video, voice, service, and control packets are converging on one network. Moxa’s PoE switches are equipped with many advanced PoE management functions, providing critical security systems with a convenient and reliable Ethernet network. Moreover, Moxa’s advanced PoE switches support the high power PoE+ standard, PD failure check, legacy PD detection, and auto power cutting.

PoE Port Settings

Click PoE on the menu, and then select the General tab on the configuration page.

Configure the following settings.

Power Output

Setting Description Factory Default Enable Enable PoE for all ports on the switch. Enabled

Disable Disable PoE for all ports on the switch.

Auto Power Cutting

Setting Description Factory Default

Enable If the total power consumption exceeds the system power budget threshold, low priority for power output of the port will perform auto power cutting.

Disabled

Disable Disable the system power budget criteria design.

System Power Budget (watt)

Setting Description Factory Default Input the value from 30 to 720

Input a value for the system power budget. 720

When finished, click Apply to save your changes.

Page 62: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-47

Editing PoE Settings for Each Port

In this section, you can also enable the PoE function for specific ports even when the system PoE is disabled under the General tab.

To edit the PoE settings for a port, click the edit icon for that port.

Edit the following parameters.

Power Output

Setting Description Factory Default Enable Enable PoE for this port. Enabled

Disable Disable PoE for this port.

Output Mode

Setting Description Factory Default

Auto Auto mode follows the 802.3af/at standard, which means the power allocation value cannot be changed manually.

Auto

High Power High Power mode follows the 802.3at standard, but High Power mode allocates 36 watts of power to the PD if it requires more than 30 watts of power.

Force Provides power output to non-802.3 af/at PDs when the detected PD has higher/lower resistance or higher capacitance and the acceptable PD resistance range exceeds 2.4 kΩ. The system will prompt you to select Force Mode to allocate 0 to 36 watts of power.

Page 63: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-48

Legacy PD Detection

The PoE Ethernet Switch includes a Legacy PD Detection function. When the capacitance of the PD is higher than 2.7 μF and less than 10 μF, enabling the Legacy PD Detection will trigger the system to output power to the PD. In this case, it will take a few seconds for PoE power to be output through this port after the switch Legacy PD Detection is enabled.

Setting Description Factory Default Enable Enable legacy PD detection. Disabled

Disable Disable legacy PD detection.

Power Allocation (watt)

Setting Description Factory Default

0 When the output mode is Auto, the value is fixed as 0. 0

36 When the output mode is High Power, the value is fixed as 36. 36

0 to 36 When the output mode is set to Force, input a value from 0 to 36.

36

Priority

Use Power Priority when managing PoE power with measured power mode. You can choose one of the following settings: critical, high, or low. When the PoE measured power exceeds the assigned limit, the switch will disable the PoE port with the lowest priority.

Setting Description Factory Default

Critical Configure the port as critical (highest) priority. Low

High Configure the port as high priority.

Low Configure the port as low priority.

Copy Config to Ports

Setting Description Factory Default

Select the port(s) from the drop-down list

Allows you to copy the configurations to other port(s). None

When finished, click Apply to save your changes.

PD Failure Check

The PoE Ethernet switch can monitor the status of a PD via its IP address. If the PD fails, the switch will not receive a PD response after the defined period, and the authentication process will be restarted. This function is extremely useful for ensuring your network’s reliability and reducing your management burden.

Select the PD Failure Check tab, and then click the edit icon on the port you want to configure.

Page 64: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-49

Configure the following parameters.

Enable

Setting Description Factory Default Enable Enable PD failure check for this port. Disabled

Disable Disable PD failure check for this port.

Device IP

Setting Description Factory Default

Input the device’s IP Specify the PD’s IP address. 0.0.0.0

Check Frequency (sec.)

Setting Description Factory Default 5 to 300 Specify how often the PD failure check will run. 10

No Response Times

Setting Description Factory Default 1 to 10 The maximum number of IP checking cycles. 3

Action

Setting Description Factory Default

No Action No action will run. No Action

Restart PD Restart the PoE device when settings are triggered.

Shutdown PD Shut down the PoE device when settings are triggered.

Copy Config to Ports

Setting Description Factory Default

Select the port(s) from the drop-down list

Copy the configurations to other port(s). None

When finished, click Apply to save your changes.

Page 65: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-50

PoE Scheduling

Note that this function is only available in Advanced Mode.

Powered devices might not need to be running 24 hours a day, 7 days a week. The PoE Ethernet switch includes a PoE scheduling mechanism that allows users to economize the system’s power burden by setting a flexible working schedule for each PoE port. Switch to Advanced Mode, click the Scheduling tab, and then click the + icon to create the scheduling settings.

Edit the following parameters.

Page 66: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-51

Rule Name

Setting Description Factory Default Input the rule name Input the name for the scheduling rule. None

Enable

Setting Description Factory Default Enable Enable PoE Scheduling for this port. Disabled

Disable Disable PoE Scheduling for this port.

Start Date

Setting Description Factory Default Input start date in the mm/dd/yyyy format

Input the start date for the rule. None

Start Time

Setting Description Factory Default Select the start time in AM/PM hh/mm format

Select the start time for the rule. None

End Time

Setting Description Factory Default

Select the end time in AM/PM hh/mm format

Select the end time for the rule. None

Repeat Execution

Setting Description Factory Default None Do not repeat the rule. None

Daily Execute the rule every day.

Weekly Execute the rule every week.

Apply the rule to port

Setting Description Factory Default Select the port(s) from the drop-down list

Copy the settings to the port(s) you want to have the same rule.

None

When finished, click Create. You can check the PoE Scheduling settings in the following figure.

Page 67: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-52

PoE Status

You can view the current PoE setting status by clicking the Status tab.

You can view the PoE status for each port. Refer to the following descriptions.

Name Description

Port PoE port on the device.

PoE Supported Check if this port supports PoE.

Power Output Power output status (on/off) for the port.

Classification Check the Classification table below for details.

Current (mA) The current (mA) that the port supplies.

Voltage (V) The voltage (V) that the port supplies.

Consumption (W) The power consumption that the device consumes.

Device Type Check the Device Type table below for details.

Configuration Suggestion Refer to the Configuration Suggestion table below for details.

PD Failure Check Disable/Alive/Not Alive.

Classification

Classification Max Power (watt) by PSE Output 0 15.4

1 4

2 7

3 15.4

4 (802.3at Type 2) 30

4 (802.3at) 30

Device Type

Item Description Not Present No connection to the port.

Legacy PoE Device A legacy PD is connected to the port, and the PD has detected that the voltage is too low or high, or the PD’s detected capacitance is too high.

IEEE 802.3af An IEEE 802.3af PD is connected to the port.

IEEE 802.3at An IEEE 802.3at PD is connected to the port.

NIC A NIC is connected to the port.

Unknown An unknown PD is connected to the port.

N/A The PoE function is disabled.

Page 68: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-53

Configuration Suggestion

Item Description Disable PoE power output When detecting a NIC or unknown PD, the system suggests disabling

PoE power output.

Enable “Legacy PD Detection” When detecting a higher capacitance of PD, the system suggests enabling Legacy PD Detection.

Select Force Mode When detecting higher/lower resistance or higher capacitance, the system suggests selecting Force Mode.

Select IEEE 802.3af/at auto mode When detecting an IEEE 802.3 af/at PD, the system suggests selecting 802.3 af/at Auto mode.

Select high power output When detecting an unknown classification, the system suggests selecting High Power output.

Raise the external power supply voltage to greater than 46 VDC

When the external supply voltage is detected at less than 46 V, the system suggests raising the voltage.

Enable PoE function for detection The system suggests enabling the PoE function.

Layer 2 Switching This section describes how to configure various parameters, such as VLAN, GARP, MAC, QoS, and Multicast, for Moxa’s switch. Click Lay 2 Switching on the function menu.

VLAN This section includes IEEE802.1Q and GARP configurations.

IEEE 802.1Q Overview

The IEEE 802.1Q is a network communication protocol that falls under the IEEE 802.1 standard regulation, allowing various segments to use a physical network at the same time to block broadcast packets by different segmentations. It specifies the VLAN tagging for Ethernet frames on switches that can control the path process.

Page 69: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-54

How A VLAN Works

What is a VLAN? A VLAN is a group of devices that can be located anywhere on a network, but which communicate as if they are on the same physical segment. With VLANs, you can segment your network without being restricted by physical connections—a limitation of traditional network design. With VLANs you can segment your network into:

• Departmental groups—You could have one VLAN for the marketing department, another for the finance department, and another for the product development department.

• Hierarchical groups—You could have one VLAN for directors, another for managers, and another for general staff.

• Usage groups—You could have one VLAN for email users and another for multimedia users.

Benefits of VLANs The main benefit of VLANs is that they provide a network segmentation system that is far more flexible than traditional networks. Using VLANs also provides you with three other benefits:

• VLANs ease the relocation of devices on networks: With traditional networks, network administrators spend much of their time dealing with changes. If users move to a different subnetwork, the addresses of each host must be updated manually. With a VLAN setup, if a host originally on the Marketing VLAN is moved to a port on another part of the network, and retains its original subnet membership, you only need to specify that the new port is on the Marketing VLAN. You do not need to do any re-cabling.

• VLANs provide extra security: Devices within each VLAN can only communicate with other devices on the same VLAN. If a device on the Marketing VLAN needs to communicate with devices on the Finance VLAN, the traffic must pass through a routing device or Layer 3 switch.

• VLANs help control traffic: With traditional networks, congestion can be caused by broadcast traffic that is directed to all network devices, regardless of whether or not they need it. VLANs increase the efficiency of your network because each VLAN can be set up to contain only those devices that need to communicate with each other.

VLANs and the Moxa switch Your Moxa switch includes support for VLANs using IEEE Std 802.1Q-2005. This standard allows traffic from multiple VLANs to be carried across one physical link. The IEEE Std 802.1Q-2005 standard allows each port on your Moxa switch to be placed as follows:

• On a single VLAN defined in the switch • On several VLANs simultaneously using 802.1Q tagging

The standard requires that you define the 802.1Q VLAN ID for each VLAN on your Moxa switch before the switch can use it to forward traffic:

Page 70: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-55

Managing a VLAN A new or initialized Moxa switch contains a single VLAN—the Default VLAN. This VLAN has the following definition:

• Management VLAN ID 1 can be changed • 802.1Q VLAN default ID 1 cannot be deleted

All the ports are initially placed on this VLAN, and it is the only VLAN that allows you to access the management software of the Moxa switch over the network.

Communication Between VLANs If devices connected to a VLAN need to communicate with devices on a different VLAN, a router or Layer 3 switching device with connections to both VLANs need to be installed. Communication between VLANs can only take place if they are all connected to a routing or Layer 3 switching device.

VLANs: Tagged and Untagged Membership Moxa’s switch supports 802.1Q VLAN tagging, a system that allows traffic for multiple VLANs to be carried on a single physical link (backbone, trunk). When setting up VLANs you need to understand when to use untagged or tagged membership of VLANs. Simply put, if a port is on a single VLAN it can be an untagged member, but if the port needs to be a member of multiple VLANs, a tagged membership must be defined.

A typical host (e.g., clients) will be an untagged member of one VLAN, defined as an Access Port in a Moxa switch, while an inter-switch connection will be a tagged member of all VLANs, defined as a Trunk Port in a Moxa switch.

The IEEE Std 802.1Q-2005 defines how VLANs operate within an open packet-switched network. An 802.1Q compliant packet carries additional information that allows a switch to determine which VLAN the port belongs to. If a frame is carrying the additional information, it is known as a tagged frame.

To carry multiple VLANs across a single physical link (backbone, trunk), each packet must be tagged with a VLAN identifier so that the switches can identify which packets belong to which VLAN. To communicate between VLANs, a router must be used.

Moxa’s switch supports three types of VLAN port settings:

• Access Port: The port connects to a single device that is not tagged. The user must define the default port PVID that assigns which VLAN the device belongs to. Once the ingress packet of this Access Port egresses to another Trunk Port (the port needs all packets to carry tag information), the switch will insert this PVID into this packet so the next 802.1Q VLAN switch can recognize it.

• Trunk Port: The port connects to a LAN that consists of untagged devices and tagged devices. In general, the traffic of the Trunk Port must have a Tag. Users can also assign a PVID to a Trunk Port. The untagged packet on the Trunk Port will be assigned the default port PVID as its VID.

• Hybrid Port: The port is similar to a Trunk port, except users can explicitly assign tags to be removed from egress packets.

The following section illustrates how to use these ports to set up different applications.

Page 71: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-56

In this application:

• Port 1 connects a single untagged device and assigns it to VLAN 5; it should be configured as an Access Port with PVID 5.

• Port 2 connects a LAN with two untagged devices belonging to VLAN 2. One tagged device with VID 3 and one tagged device with VID 4. It should be configured as a Hybrid Port with PVID 2 for untagged device and Fixed VLAN (Tagged) with 3 and 4 for tagged device. Since each port can only have one unique PVID, all untagged devices on the same port must belong to the same VLAN.

• Port 3 connects with another switch. It should be configured as a Trunk Port. GVRP protocol will be used through the Trunk Port.

• Port 4 connects a single untagged device and assigns it to VLAN 2; it should be configured as an Access Port with PVID 2.

• Port 5 connects a single untagged device and assigns it to VLAN 3; it should be configured as an Access Port with PVID 3.

• Port 6 connect a single untagged device and assigns it to VLAN 5; it should be configured as an Access Port with PVID 5.

• Port 7 connects a single untagged device and assigns it to VLAN 4; it should be configured as an Access Port with PVID 4.

After the application is properly configured:

• Packets from Device A will travel through Trunk Port 3 with tagged VID 5. Switch B will recognize its VLAN, pass it to port 6, and then remove tags received successfully by Device G, and vice versa.

• Packets from Devices B and C will travel through Hybrid Port 2 with tagged VID 2. Switch B recognizes its VLAN, passes it to port 4, and then removes tags received successfully by Device F, and vice versa.

• Packets from Device D will travel through Trunk Port 3 with tagged VID 3. Switch B will recognize its VLAN, pass to port 5, and then remove tags received successfully by Device H. Packets from Device H will travel through Trunk Port 3 with PVID 3. Switch A will recognize its VLAN and pass it to port 2, but will not remove tags received successfully by Device D.

• Packets from Device E will travel through Trunk Port 3 with tagged VID 4. Switch B will recognize its VLAN, pass it to port 7, and then remove tags received successfully by Device I. Packets from Device I will travel through Trunk Port 3 with tagged VID 4. Switch A will recognize its VLAN and pass it to port 2, but will not remove tags received successfully by Device E.

VLAN Settings

To configure VLAN, click VLAN on the function menu, then select IEEE 802.1Q. Click Global tab.

GVRP (Generic VLAN Registration Protocol) is an IEEE 802.1Q standard protocol that helps specify how to define a method of tagging frames with VLAN configuration data. It essentially facilitates management of VLAN within a larger network data communication.

To edit the GVRP function, click the GVRP tab.

Page 72: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-57

Configure the following setting.

GVRP

Setting Description Factory Default Disabled Disables GVRP. Disabled

Enabled Enables GVRP.

Click Apply to finish.

VLAN Management Port Quick Setting

In the lower part of the configuration page, you can quickly configure VLAN setting.

Configure the following settings.

Management VLAN

Setting Description Factory Default

Select the Management VLAN from the drop-down list

Show the list of selectable VLANs. 1

Management Port

Setting Description Factory Default Select the port(s) as the VLAN port(s) from the drop-down list

To select the port(s) as the VLAN port(s). None

When finished, click Apply to save your changes.

Detailed VLAN Settings

On the IEEE 802.1Q page, first click the Setting tab, and then click the edit icon.

Page 73: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-58

Configure the following parameters.

VID

Setting Description Factory Default Input a VLAN ID, (10 VLANs max.)

Input a VLAN ID. None

Name

Setting Description Factory Default Input a name for the VLAN, (32 characters max.)

Specify a name for the VLAN. None

Member Port

Setting Description Factory Default

Select the port from the drop-down list.

Specify the ports that are the member ports for the VLAN. None

When finished, click Create.

Forbidden Port (in Advanced Mode only)

Setting Description Factory Default Select the port from the drop-down list

Specify the ports that are forbidden for the VLAN. None

Editing the Existing VLAN Settings

To edit the exiting VLAN settings, click the edit icon of the VLAN you want to edit.

Page 74: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-59

Configure the following settings.

VID

Setting Description Factory Default Show the VLAN ID Display the VLAN ID. None

Name

Setting Description Factory Default Show the name of the VLAN

Display the VLAN name. None

Member Port

Setting Description Factory Default

Select the port from the drop-down list

Specify the ports that are member ports for the VLAN. None

When finished, click Apply to save your changes.

Forbidden Port (in Advanced Mode only)

Setting Description Factory Default Select the port from the drop-down list

Specify the ports that are forbidden for the VLAN. None

Editing the Port Settings

To edit the port settings, in the VLAN tab select the edit icon on the port you want to configure on the lower part of the page.

Page 75: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-60

Configure the following settings.

Mode

Setting Description Factory Default Access When this port is connected to a single device, without tags. Access

Trunk When this port is connected to another 802.1Q VLAN aware switch.

Hybrid When this port is connected to another Access 802.1Q VLAN aware switch or another LAN that combines tagged and/or untagged devices.

PVID

Setting Description Factory Default 1 to 4094 Sets the default VLAN ID for untagged devices connected to the

port. None

GVRP

Setting Description Factory Default Enabled Enables GVRP. Disabled

Disabled Disables GVRP.

Tagged VLAN

Setting Description Factory Default 1 to 4094 This field will be active only when selecting the Trunk or Hybrid

port type. Set the other VLAN ID for tagged devices that connect to the port.

None

Untagged VLAN

Setting Description Factory Default VID range from 1 to 4094

This field is only active when the Hybrid port type is selected. Set the other VLAN ID for tagged devices that connect to the port and tags that need to be removed in egress packets.

1

Page 76: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-61

Copy Config to Ports

Setting Description Factory Default Select the port(s) from the drop-down list

Copy the configuration to other port(s). None

When finished, click Apply to save your changes.

GARP Overview

GARP stands for Generic Attribute Registration Protocol, which is a communication protocol defined by IEEE 802.1, offering a generic framework for bridges to register and de-register an attribute value. In a VLAN structure, two applications can be applied: GARP VLAN Registration Protocol (GVRP) is used to register VLAN trunking between multilayer switches, and GARP Multicast Registration Protocol (GMRP) for providing a constrained multicast flooding facility.

GARP Settings

Select GARP on the menu page, and then click the edit icon on the port you want to configure.

Configure the following settings.

Join Time (sec.)

Setting Description Factory Default 10 to 499999980 Input the join time from 10 to 499999980 seconds. 200

Page 77: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-62

Leave Time (sec.)

Setting Description Factory Default 30 to 499999980 Input the leave time from 30 to 499999980 seconds. 600

Leave All time (sec.)

Setting Description Factory Default 30 to 499999990 Input the leave all time. 10000

Copy Config to Ports

Setting Description Factory Default

Select the port(s) from the drop-down list

Copy the configurations to other port(s). None

When finished, click Apply to save your changes.

MAC This section explains Independent VLAN learning and describes how to configure Static Unicast and the MAC Address Table.

Independent VLAN Learning

Moxa’s switch uses the Independent VLAN Learning (IVL) mode.

In an IVL Mode, a MAC table will be created in each VLAN, which will constitute many MAC tables. However, the same VID record will be selected and put in a table. A MAC table will be stored in the format of MAC + VID, the same MAC will be stored in different tables with different VIDs.

Static Unicast

Click Static Unicast on the function menu page and click the + icon on the configuration page.

Page 78: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-63

Configure the following settings.

VID

Setting Description Factory Default Input a VLAN ID Input a VLAN ID. None

MAC Address

Setting Description Factory Default MAC address of the port Input the MAC address of the port. None

Port

Setting Description Factory Default

Select the port from the drop-down list

Specify the port you want to create a VLAN for. None

When finished, click Create.

MAC Address Table

Select MAC Address Table, and configure the following settings.

MAC Learning Mode

Information Description Factory Default Independent VLAN learning

Show the current MAC Learning Mode. Independent VLAN learning

Aging Time

Setting Description Factory Default 10 to 300 Input a VLAN ID. None

When finished, click Apply to save your changes. You can view the current MAC Address Table on the bottom part of the configuration page.

Page 79: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-64

Item Name Description

Index The number of the MAC address.

VLAN The VLAN number

MAC Address The MAC address on this device.

Type Learnt Unicast, Learnt Multicast, Static Unicast, Static: Multicast

Port The forwarding port of this MAC address.

QoS This section describes how QoS works and how to configure the settings.

QoS Overview

The switch’s traffic prioritization capability provides Quality of Service (QoS) to your network by making data delivery more reliable. You can prioritize traffic on your network to ensure that high priority data is transmitted with minimum delay. Traffic can be controlled by a set of rules to obtain the required Quality of Service for your network. The rules define different types of traffic and specify how each type should be treated as it passes through the switch. The switch can inspect both IEEE 802.1p/1Q layer 2 CoS (Class of Service) tags, and even layer 3 DSCP (Differentiated Services Code Point) information to provide consistent classification of the entire network. The switch’s QoS capability improves the performance and determinism of industrial networks for mission-critical applications.

Page 80: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-65

The Traffic Prioritization Concept

Traffic prioritization allows you to prioritize data so that time-sensitive and system-critical data can be transferred smoothly and with minimal delay over a network. The benefits of using traffic prioritization are:

• Improve network performance by controlling a wide variety of traffic and by managing congestion. • Assign priorities to different categories of traffic. For example, set higher priorities for time-critical or

mission-critical applications. • Provide predictable throughput for multimedia applications, such as video conferencing or voice over IP,

and minimize traffic delay and jitter. • Optimize the network utilization depending on application usage and usage needs. Hence, asset owners do

not always need to expand their backbone bandwidth as the amount of traffic increases.

Traffic prioritization uses eight traffic queues to ensure that higher priority traffic can be forwarded separately from lower priority traffic, which guarantees Quality of Service (QoS) to your network.

Moxa switch traffic prioritization is based on two standards:

• IEEE 802.1p - a layer 2 QoS marking scheme • Differentiated Services (DiffServ)—a layer 3 QoS marking scheme.

IEEE 802.1p Class of Service The IEEE Std 802.1D 2005 Edition marking scheme, which is an enhancement to IEEE Std 802.1D, enables Quality of Service on the LAN. Traffic service levels are defined in the IEEE 802.1Q 4-byte tag, which is used to carry VLAN identification as well as IEEE 802.1p priority information. The IEEE 802.1p occupying 3 bits of the tag follows the destination MAC address and Source MAC address.

The IEEE Std 802.1D 2005 Edition priority marking scheme assigns an IEEE 802.1p priority level between 0 and 7 to each frame, which specifies the level of service that the associated packets shall be handled. The table below shows an example of how different traffic types can be mapped to the eight IEEE 802.1p priority levels.

IEEE 802.1p Priority Level IEEE 802.1D Traffic Type 0 Best Effort

1 Background (lowest priority)

2 Reserved

3 Excellent Effort (business critical)

4 Controlled Load (streaming multimedia)

5 Video (interactive media)

6 Voice (interactive voice)

7 Network Control Reserved traffic

Even though the IEEE 802.1p standard is the most widely used prioritization scheme for LAN environments, it still has some restrictions:

• It requires an additional 4-byte tag in the frame, which is normally optional for Ethernet networks. Without this tag, the scheme cannot work.

• The tag is part of the IEEE 802.1Q header, so to implement QoS at layer 2, the entire network must implement IEEE 802.1Q VLAN tagging.

• It is only supported within a LAN and does not cross the WAN boundaries, since the IEEE 802.1Q tags will be removed when the packets pass through a router.

Page 81: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-66

Differentiated Services (DiffServ) Traffic Marking DiffServ is a Layer 3 marking scheme that uses the DiffServ Code Point (DSCP) field in the IP header to specify the packet priority. DSCP is an advanced intelligent method of traffic marking that allows you to choose how your network prioritizes different types of traffic. The DSCP field can be set from 0 to 63 to map to user-defined service levels, enabling users to regulate and categorize traffic by applications with different service levels.

The advantages of DiffServ over IEEE 802.1Q are as follows:

• You can prioritize and assign different traffic with appropriate latency, throughput, or reliability by each port.

• No extra tags are required. • The DSCP priority tags are carried in the IP header, which can pass the WAN boundaries and through the

Internet. • DSCP is backwards compatible with IPv4 ToS (Type of Service), which allows operation with legacy devices

that use IPv4 layer 3.

Traffic Prioritization Moxa switches classify traffic based on layer 2 of the OSI 7 layer model, and the switch prioritizes outbound traffic according to the priority information defined in the received packet. Incoming traffic is classified based upon the IEEE 802.1p service level field and is assigned to the appropriate egress priority queue. The traffic flow through the switch is as follows:

• A packet received by the Moxa switch may or may not have an 802.1p tag associated with it. If it does not, then it is given a default CoS value (according to the port settings in the classification section). Alternatively, the packet might be marked with a new 802.1p value, which will result in all knowledge of the previous 802.1p tag being lost.

• Each egress queue has associated 802.1p priority levels, and can be defined by users, the packet will be placed in the appropriate priority queue. When the packet reaches the head of its queue and is about to be transmitted, the device determines whether or not the egress port belongs to the VLAN group. If it is, then the new 802.1p tag is used in the extended 802.1D header.

Traffic Queues The hardware of Moxa switches has multiple traffic queues that allow packet prioritization to occur. Higher priority traffic can pass through the Moxa switch without being delayed by lower priority traffic. As each packet arrives in the Moxa switch, it undergoes ingress processing (which includes classification, marking/re-marking), and is then sorted into the appropriate queue. The switch then forwards packets from each queue.

Moxa switches support two different queuing mechanisms:

• Weight Fair: This method services all the traffic queues, giving priority to the higher priority queues. Under most circumstances, the Weight Fair method gives high priority precedence over low priority, but in the event that high priority traffic does not reach the link capacity, lower priority traffic is not blocked.

• Strict: This method services high traffic queues first; low priority queues are delayed until no more high priority data needs to be sent. The Strict method always gives precedence to high priority over low priority.

Page 82: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-67

Classification

There are three parameters in this section: DSCP Mapping, CoS Mapping, and Port Setting. The three parameters are described below in detail.

DSCP to CoS Mapping

In the Classification menu, click the DSCP Mapping tab, and then click the edit icon.

Configure the priority setting from the drop-down list for this port.

DSCP Value and Priority

Setting Description Factory Default 0 to 7 Different DSCP values map to one of eight different priorities

from 0 to 7. 0

8 to 15 1

16 to 23 2

24 to 31 3

32 to 39 4

40 to 47 5

48 to 55 6

56 to 63 7

When finished, click Apply to save your changes.

Page 83: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-68

CoS to Queue Mapping

In the Classification menu, click the CoS Mapping tab, and then click the edit icon.

Configure the Queue priority setting for the port.

Queue Priority

Setting Description Factory Default 0 Different 802.1p values map to one of the eight different

queues from 1 (lowest priority) to 8 (highest). 1

1 2

2 3

3 4

4 5

5 6

6 7

7 8

Page 84: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-69

Port Settings

In the Classification menu, click the Port Setting tab, and then click the edit icon.

Configure the following settings.

Trust Type

Setting Description Factory Default CoS Enables the port with CoS-based traffic classification. CoS

DSCP Enables the port with DSCP-based traffic classification.

Untag Default Priority

Setting Description Factory Default

0 to 7 802.1p tag (CoS) can be range from 0 (lowest) to 7 (highest). 3

Copy Config to Ports

Setting Description Factory Default Select from the drop-down list

Copy the settings to other ports you select. None

When finished, click Apply to save your changes.

Page 85: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-70

Ingress Rate Limit

Ingress Rate Limit Overview

The rate limit is composed of the meter and the marker. The meter is the monitoring of the data rates for a particular class of traffic. When the data rate exceeds user-configured values, marking or dropping of packets occurs immediately. The meter does not buffer the traffic; therefore, the transmission delay is not affected. When traffic exceeds the user’s specified value, you can instruct the system to either drop the packets or mark QoS fields in them. The meter algorithms include simple token bucket and SrTCM (Single Rate Three Color Marker) (RFC2697). The marker of the rate limit is included and remarked in the 802.1p or the DSCP field of the packet.

Simple Token Bucket

The Token Bucket Concept

Token Bucket is an algorithm used to achieve an efficient network flow control and manage bandwidth. This algorithm is based on a token bucket that allows for a traffic surge for short periods. When a token is unavailable, no burst of packets can be sent. Under this concept, the number of tokens will be refilled in the bucket at specific intervals. Users need to configure these settings so that the tokens in the bucket are always available to ensure packets can be sent when necessary.

Page 86: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-71

CAR (Committed Access Rate) is a traffic control mechanism used to ensure that packets meet the network rules before they enter the network. CAR can guarantee the traffic flow is under user-defined control; the packets exceeding the rule will be either dropped or remarked and transmitted again. When network traffic is jammed, these packets will be dropped first.

Token Bucket is an algorithm that is demonstrated as a container in the image below. The token can be seen as a marker to mark a packet that is allowed to be transmitted through this switch. When the token is flowing into the bucket, the length of the bucket will be consumed as the volume of the bucket is limited. When the volume of the bucket is insufficient, some packets will be dropped or remarked and transmitted again. This algorithm can control the speed of the traffic flow by consuming the speed of the token in the bucket.

Page 87: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-72

Simple Token Bucket Concept

In the Simple Token Bucket algorithm, two methods will be used:

CIR: Committed Information Rate: Users can pre-configure the CIR. To determine the size of the bucket, they will be sent along with the available tokens. When tokens are unavailable, the packets will not be sent until the tokens are added into the bucket. This guarantees sufficient network bandwidth and efficient flow control.

CBS: Committed Burst Rate: The tokens will be saved in both the CBS bucket and EBS bucket. When both buckets are full of tokens, the exceeding tokens will be dropped. This ensures that the specific amount of tokens are available so that the packet transmission can be stable.

Page 88: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-73

SrTCM (Single Rate Three Color Marker)

SrTCM Overview

SrTCM stands for A Single Rate Three Color Marker, which is another policing scheme for ingress rate limit. Traffic marking is based on a Committed Information Rate (CIR) and two associated burst sizes, a Committed Burst Size (CBS) and an Excess Burst Size (EBS). A packet is marked green if it does not exceed the CBS, yellow if it does exceed the CBS, but not the EBS, and red otherwise.

How SrTCM Works

SrTCM will categorize the ingress packet by its length, and mark it as one of three colors:

Red: performs the "violate" action.

Yellow: performs the "exceed" action. The Token Bucket (EBS) will deduct corresponding tokens.

Green: performs the "conform" action. The Token Bucket (CBS) will deduct corresponding tokens.

The SrTCM is useful for ingress policing of a service, where only the length, not the peak rate, of the burst determines service eligibility.

Page 89: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-74

Exceed Rate Limit Threshold Port Shutdown

In general, any user shall not consume unlimited bandwidth and influence others' access. One particular scenario is that a malfunctioning switch or mis-configured network might cause "broadcast storms". Moxa industrial Ethernet switches not only prevent broadcast storms, but can also regulate ingress packet rates, giving administrators full control of their limited bandwidth to prevent undesirable effects caused by unpredictable faults.

Editing Ingress Rate Limit

Switch to Advanced Mode before configuring the settings in this section.

On the Ingress Rate Limit menu, click the General tab, and then click the edit icon.

Page 90: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-75

Configure the following settings.

Type

Setting Description Factory Default Simple Token Bucket Specify Simple Token Bucket as Ingress Limit type. Simple Token

Bucket SrTCM Specify SrTCM as Ingress Limit type.

Ingress Rate (CIR) (Mbps)

Setting Description Factory Default

1 to 1000 Define the specific incoming data communication speed given to this port.

1000

CBS (Committed Burst Size) (Kbyte)

Setting Description Factory Default 0 to 10240 Input the specific data communication speed given to this port

when the data rate exceeds the CIR rate. The data that exceeded the CIR rate will be saved in temporary storage, and will be sent when bandwidth is available.

1024

EBS (Excess Burst Size) (Kbyte)

Setting Description Factory Default 0 to 10240 Input the specific data communication speed given to this port

when the data rate exceeds the CIR rate. The data that exceeded the CIR rate will be saved in temporary storage, and will be sent when bandwidth is available.

1024

Confirm Action

Setting Description Factory Default

Do Nothing Do nothing. Do Nothing

Remark CoS Remark the CoS value.

Remark DSCP Remark the DSCP value.

Page 91: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-76

Violate Action

Setting Description Factory Default Drop Drop the packet if the packet violates CIR and CBS. Drop

Remark CoS Remark the CoS value if the packet is marked as violated.

Remark DSCP Remark the DSCP value if the packet is marked as violated.

Copy Config to Ports

Setting Description Factory Default Select the port(s) from the drop-down list

Copy the configurations to other port(s). None

When finished, click Apply to save your changes.

Editing Port Shutdown

To edit the port shutdown configurations, click the Port Shutdown tab.

Configure the following settings.

Enable

Setting Description Factory Default Enable Enable the port to be shut down. Disabled

Disable Disable the ability for the port to be shut down.

Release Interval (min.)

Setting Description Factory Default 0 to 10080 Specify the release interval for the port to shut down. 0 means

this port will be shut down until manually enabled. 60

When finished, click Apply to save your changes.

Page 92: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-77

Editing the Port for Port Shutdown

Edit the specific port that you want to edit the port shutdown configurations for.

Configure the following settings.

Enable

Setting Description Factory Default Enable Enable port shutdown for this port. Disable

Disable Disable port shutdown for this port.

Threshold (Mbps)

Setting Description Factory Default

1 to 1000 Specify the threshold for port shutdown 1000

Copy Config to Ports

Setting Description Factory Default Select the port(s) from the drop-down list

Copy the configurations to other port(s). None

When finished, click Apply to save your changes.

Page 93: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-78

Scheduler

Scheduler Overview

Scheduler is an arbiter in switch forwarding path to prioritize traffic flows by users' defined criteria. This essentially enhances data transmission efficiency and guarantees that critical packets can be transmitted earlier. Moxa’s switches support two scheduling algorithms: Strict Priority and Weighted Round Robin.

Strict Priority

The Strict Priority type allows users to determine to transmit packets in the highest priority queue first, while packets with lower priority will be transmitted later. This guarantees that traffic with the highest level of priority for data transmission will go first.

Weighted Round Robin

The Weighted Round Robin type allows users to give priority to specific packets in the higher weighted queue to ensure those packets will be sent first. Moxa switches now have 8 queues, and the weights from highest to lowest are 8:8:4:4:2:2:1:1.

Scheduler Settings

Select Scheduler in the menu and then click the edit icon on the port you want to configure.

Configure the following settings.

Page 94: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-79

Type

Setting Description Factory Default Strict Priority Set scheduler algorithm as Strict Priority. Strict Priority

Weighted Round Robin Set the scheduler algorithm as Weighted Round Robin: The queued packet will be forwarded by its associated weight.

Copy Config to Ports

Setting Description Factory Default

Select the port from the drop-down list

Copy the same settings to other ports. None

When finished, click Apply to save your changes.

Egress Shaper Overview

A shaper typically delays excess traffic using a buffer or queueing mechanism to hold packets and shape the flow when the data rate of the source is higher than expected. There are two possible metering algorithms: token bucket, or leaky bucket. The leaky bucket algorithm works similarly to the way an actual leaky bucket holds water: The leaky bucket takes data and collects it up to a maximum capacity. Credit in the bucket is only released from the bucket at a set rate. When the bucket consumes all data, the leaking will stop. If incoming data would overfill the bucket, then the packet is considered to be non-conformant and is not added to the bucket. Data will be added back to the bucket as space becomes available for conforming packets.

Egress Shaper Settings and Status

This section describes how to configure Egress Shaper. Switch to Advanced Mode first, and select Egress Shaper in the menu and then click the edit icon on the port you want to configure.

Page 95: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-80

Configure the following settings.

CIR (Committed Information Rate) (Mbps)

Setting Description Factory Default 1 to 1000 The average committed data transmission rate. 1000

CBS (Committed Burst size) (Kbyte)

Setting Description Factory Default 10 to 10240 The maximum traffic amount (in Kbyte) that can be

transmitted within a very short interval of time or burst. 1024

Copy Config to Ports

Setting Description Factory Default

Select the port from the drop-down list

Copy the same settings to the other ports. None

When finished, click Apply to save your changes. You can view the Egress Shaper status.

Page 96: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-81

Multicast Multicast filtering improves the performance of networks that carry multicast traffic. This section will explain the Layer 2 multicast settings, such as IGMP Snooping, GMRP, and Static Multicast.

IGMP Snooping

IGMP Snooping Overview

IGMP stands for Internet Group Management Protocol, which is a network communication protocol that hosts nearby routers on networks to construct multicast group memberships.

IGMP snooping allows a network switch to listen in on the IGMP conversation between hosts and routers. By listening to these conversations, the switch maintains an association mapping table between port(s) and multicast group.

How IGMP Snooping Works

A switch will, by default, flood multicast traffic to all the other ports, aside ingress, in a broadcast domain (or the VLAN equivalent). Multicast can cause unnecessary loading for host devices by requiring them to process packets they have not solicited. IGMP snooping is designed to prevent hosts on a local network from receiving traffic for a multicast group they have not explicitly joined. It provides switches with a mechanism to forward

multicast traffic to specific ports that receive IGMP hosts. Hence, IGMP snooping can utilize the network bandwidth more efficiently.

Without IGMP Snooping

Page 97: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-82

With IGMP Snooping

Differences Between IGMP Snooping V1, V2, and V3

IGMP protocols regulate the communication mechanism between querier and listener. IGMP Snooping has three different versions. Refer to the following table for the detailed differences.

IGMP Version Main Features Reference V1 The IGMPv1 querier will periodically send out a "query". Listeners can

solicit a "report" of their interested group. However, IGMPv1 does not have a "leave group" message, and the querier might need to implement a timeout mechanism for each registered group.

RFC-1112

V2 Compatible with V1 and the following functions: a. Group-specific query b. Leave group messages c. Resends specific queries to verify leave message was the last one in the group d. Querier election if multiple capable queries are present.

RFC-2236

V3 Compatible with V1, V2, and the following functions: Source filtering enables hosts to specify: - the multicast traffic from a specified source - the multicast traffic from any source except a specified source

RFC-3376

IGMP Snooping Settings

First, select IGMP Snooping on the menu and then click the General tab on the configuration page.

Enable

Setting Description Factory Default Enabled Enable IGMP Snooping on a specific VLAN. Disabled

Disabled Disable IGMP Snooping on a specific VLAN.

Page 98: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-83

Configuring VLAN Setting

Click the VLAN Setting tab, and then click the edit icon to configure the VLAN settings.

Enable

Setting Description Factory Default Enabled Enable IGMP Snooping on a switch. Disabled

Disabled Disable IGMP Snooping on a switch.

Version

Setting Description Factory Default

1, 2, 3 Specify the IGMP version of the packets that the switch listens to and send queries for.

2

Query Interval (sec)

Setting Description Factory Default 20 to 600 Specify the query interval for the Querier function globally

(Querier has to be enabled.) 125

Page 99: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-84

Static Router Port

Setting Description Factory Default Check the port from the drop-down list

The router port is the port that connects to the upper level router (or IGMP querier), or to the upper level router of downstream multicast streams. All of the received IGMP signaling packets or multicast streams will be forwarded to those static router ports.

None

Config Role

Setting Description Factory Default Querier The switch will act as the Querier role. Querier

Non-Querier The switch will not act as the Querier role.

When finished, click Apply to save your changes.

Viewing the Group Table

Click the Group Table tab, which allows you to view the current Group Table status.

Refer to the following table for the detailed description for each item.

Item Description

VLAN The VLAN ID.

Group Address The registered multicast group.

Filter Mode Only applicable for IGMPv3. (v1 and v2 will display "N/A") Include: source-specific multicast address group Exclude: source-specific exclusive multicast address group

Port The forwarded port.

Source Address Only applicable for IGMPv3. (v1 and v2 will display N/A)

Viewing the Forwarding Table

Click the Forwarding Table tab to view the current forwarding table.

Page 100: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-85

Refer to the following table for a description of each item.

Item Description

VLAN The VLAN ID.

Group Address The associated multicast group address of the streaming data.

Source Address The source address of the streaming data.

Port The forwarded port.

GMRP

GMRP stands for GARP Multicast Registration Protocol, which is a Generic Attribute Registration Protocol (GARP) application that can be used to prevent multicast from data flooding. Both GMRP and GARP are defined by the IEEE 802.1P, and widely used as a standard protocol in various industrial-related applications. GMRP allows bridges and the devices at the edge of the network to perform a dynamic group membership information registration with the MAC bridges connected to the same LAN section. The information can be transmitted among all bridges in the Bridge LAN that is implemented with extended filtering features. To operate GMRP, the GARP service must be established first.

Configuring GMRP Setting

To configure the GMRP settings, click GMRP on the menu.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable GMRP. Disabled

Disabled Disable GMRP.

When finished, click Apply to save your changes.

Configuring GMRP Settings for Each Port

Next, click the edit icon on the port you want to configure.

Page 101: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-86

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable GMRP for this port. Disabled

Disabled Disable GMRP for this port.

Group Restrict

Setting Description Factory Default

Enabled Enable Group Restrict on the port. This specific port will not process any GMRP control packets.

Disabled

Disabled Disable Group Restrict on the port. The specific port will receive and process incoming GMRP control packets.

Copy Config to Ports

Setting Description Factory Default Select the port(s) from the drop-down list

Allows you to copy the configurations to other port(s). None

When finished, click Apply to save your changes.

Static Multicast

Click Static Multicast on the menu to view the current multicast table.

Adding Static Multicast Entry

To add more tables, click the + icon.

Page 102: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-87

Configure the following settings.

VID (VLAN ID)

Setting Description Factory Default Input the VID Specify the multicast group's associated VLAN ID. None

MAC Address

Setting Description Factory Default Input the MAC address Specify the multicast MAC address. None

Egress Port

Setting Description Factory Default

Input the port from the drop-down list

Set the port(s) as an egress port(s) so that multicast streams can be forwarded to this port.

None

Forbidden Port

Setting Description Factory Default Input the port from the drop-down list

Set the port as forbidden so that packets cannot be forwarded to this port.

None

When finished, click Create.

Network Redundancy Setting up the Redundancy Protocol on your network helps protect critical links against failure, protects against network loops, and keeps network downtime to a minimum.

The Redundancy Protocol allows you to set up redundant paths on the network to provide a backup data transmission route in the event that a cable or one of the switches is inadvertently disconnected or damaged. This is a particularly important feature for industrial applications, since it can take several minutes to address the link down port or failed switch. For example, if a Moxa switch is used as a key communications device for a production line, several minutes of downtime can cause a big loss in production and revenue. Moxa switches support the following Redundancy Protocol functions:

• Spanning Tree

• Turbo Ring V2

• Turbo Chain

• Dual Homing

Page 103: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-88

Layer 2 Redundancy First select Network Redundancy on the menu and then click Layer 2 Redundancy.

Spanning Tree

Spanning Tree Overview

Spanning Tree Protocol (STP) was designed to help construct a loop-free logical typology on an Ethernet network, and provide an automatic means of avoiding any network loops. This is particularly important for networks that have a complicated architecture, since unintended loops in the network can cause broadcast storms. Moxa switches’ STP feature is disabled by default. To be completely effective, you must enable STP/RSTP on every Moxa switch connected to your network.

STP (802.1D) is a bridge-based system that is used to implement parallel paths for network traffic. STP uses a loop-detection process to:

• Locate and then disable less efficient paths (e.g., paths that have lower bandwidth).

• Enable one of the less efficient paths if a more efficient path fails.

How STP Works

The figure below shows a network made up of three LANs separated by three bridges. Each segment uses at most two paths to communicate with the other segments. Since this configuration can give rise to loops, the network will overload if STP is not enabled.

Page 104: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-89

If STP is enabled, it will detect duplicate paths or block one of the paths from forwarding traffic. In the following example, STP determined that traffic from segment 2 to segment 1 flows through switches C and A since this path is in a forwarding state and is processing BPDUs. However, switch B on segment 1 is in a blocking state.

What happens if a link failure is detected? As shown in the figure below, the STP will change the blocking state to a forwarding state so that traffic from segment 2 flows through switch B to segment 1 through a redundant path.

STP will determine which path between each segment is most efficient, and then assign a specific reference point on the network. When the most efficient path has been identified, the other paths are blocked. In the previous three figures, STP first determined that the path through switch C was the most efficient, and as a result, blocked the path through switch B. After the failure of switch C, STP re-evaluated the situation and opened the path through switch B.

Difference Between STP and RSTP

RSTP is similar to STP but includes additional information in the BPDUs that allow each bridge to confirm that it has taken action to prevent loops from forming when it decides to enable a link to a neighboring bridge. Adjacent bridges connected via point-to-point links will be able to enable a link without waiting to ensure that all other bridges in the network have had time to react to the change. The main benefit of RSTP is that the configuration decision is made locally rather than network-wide, allowing RSTP to carry out automatic configuration and restore a link faster than STP.

STP and RSTP spanning tree protocols operate without regard to a network’s VLAN configuration and maintain one common spanning tree throughout a bridged network. Thus, these protocols map one loop-free, logical topology on a given physical topology.

Page 105: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-90

STP/RSTP Settings and Status

This section describes how to configure Spanning Tree settings.

General Click Spanning Tree on the menu and then select the General tab.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Spanning Tree. Disabled

Disabled Disable Spanning Tree.

STP Mode

Setting Description Factory Default STP/RSTP Use the STP/RSTP mode as the Spanning Tree protocol. STP/RSTP

Compatibility

Setting Description Factory Default STP To be compatible with STP mode only RSTP

RSTP To be compatible with RSTP and STP modes

Bridge Priority

Setting Description Factory Default 0 to 61440 Increase this device’s bridge priority by selecting a lower

number. A device with a higher bridge priority has a greater chance of being established as the root of the Spanning Tree topology.

32768

Forwarding Delay Time (sec.)

Setting Description Factory Default 4 to 30 The amount of time the device waits before checking to see if it

should change to a different state. 15

Hello Time (sec.)

Setting Description Factory Default

1 or 2 The root of the Spanning Tree topology periodically sends out a 2

Page 106: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-91

“hello” message to other devices on the network to check if the topology is healthy. The “hello time” is the amount of time the root waits between sending hello messages.

Max Age (sec.)

Setting Description Factory Default

6 to 40 If this device is not the root, and it has not received a hello message from the root in the amount of time equal to “Max. Age,” then this device will reconfigure itself as a root. Once two or more devices on the network are recognized as a root, the devices will renegotiate a new Spanning Tree topology.

20

Error Recovery Time (sec.)

Setting Description Factory Default 30 to 65535 If the BPDU guard is triggered on a port, it will automatically

recover to the normal state after the Error Recovery Time. 300

When finished, click Apply to save your changes.

Editing Spanning Tree for a Port To edit the spanning tree settings for a specific port, click the edit icon on the port you want to configure.

Configure the following settings.

Enable

Setting Description Factory Default

Page 107: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-92

Enabled Enable Spanning Tree. Disabled

Disabled Disable Spanning Tree.

Edge

Setting Description Factory Default Auto Automatically detect to be the edge port. Auto

Yes Set as an edge port.

No Do not set as an edge port.

Priority

Setting Description Factory Default 0 to 255 (multiples of 16)

Increase the priority of a port by selecting a lower number. A port with a higher priority has a greater chance of being a root port.

128

Path Cost

Setting Description Factory Default 0 to 20000000 The path cost value will be automatically assigned according to

the different port speed if the value is set to zero. 0

Link Type

Setting Description Factory Default

Force True Set to Force True when port operating in full-duplex mode, such as a switch.

Auto

Force False Set to Force False when port operating in half-duplex mode, such as a hub.

Auto Automatically select Force True or Force False mode.

Copy Config to Ports

Setting Description Factory Default

Select the port(s) from the drop-down list

Copy the configurations to other port(s). None

Click Apply to finish.

BPDU Overview

BDPUs (Bridge Protocol Data Units) are the network communication frames used in the STP (Spanning Tree Protocol). When two switches exchange messages, BDPUs are used to calculate the STP topology, and determine the network communication route. A BDPU filter is often used to screen sending or receiving BPDUs on a specific port of the switch.

BPDU Guard

BDPU Guard is a protection mechanism that prevents a port from receiving BPDUs. When an RSTP-enabled port receives BPDUs, it will automatically be in the error-disable state, which means the port will in turn switch to Block state. When STP is enabled, all ports are involved in the STP domain, sending and receiving BPDUs. However, when BPDU Guard is enabled, all ports will not receive or send any BPDUs, as all computers and unmanaged switches do not support STP. When BPDU Guard is enabled, all communications will be treated as error-disabled, and the related ports will be blocked, therefore no more data will be sent or received, protecting the network from a loop chain.

Root Guard

Root Guard prevents a designated port role from changing to root port role on reception of superior information.

Page 108: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-93

Loop Guard

Loop Guard prevents temporary loops in a network caused by non-designated ports changing to the spanning-tree forwarding state due to a link failure in the topology.

BPDU Filter

BPDU Filter prevents a port from sending and processing BPDUs. A BPDU filter enabled port cannot transmit any BPDUs and drop all received BPDU either.

Configuring BPDU Filter, BPDU/Root/Loop Guard Settings

First click Spanning Tree on the menu and then select the Guard tab. Next, click the edit icon on the port you want to configure.

Configure the following settings.

BDPU Guard

Setting Description Factory Default Enabled Enable BDPU Guard. Disabled

Disabled Disable BDPU Guard.

Page 109: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-94

NOTE To establish a redundant port e.g. it is highly recommended that you do not enable BPDU filter.

Root Guard

Setting Description Factory Default Enabled Enable Root Guard. Disabled

Disabled Disable Root Guard.

Loop Guard

Setting Description Factory Default

Enabled Enable Loop Guard. Disabled

Disabled Disable Loop Guard.

BDPU Filter

Setting Description Factory Default Enabled Enable BDPU Filter. Disabled

Disabled Disable BDPU Filter.

Copy Config to Port

Setting Description Factory Default Select the port(s) from the drop-down list

Copy the same settings to other port(s). None

When finished, click Apply to save your changes.

Viewing Current Spanning Tree Status

Click the Status tab to view the current Spanning Tree status.

Page 110: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-95

In addition, the status for each port will also be shown below.

Refer to the following table for detailed description of each item.

Item Description

Port The port number on this device.

Edge Show if this port is connected to an edge device.

Port Rule Root: The port is connected directly or indirectly to the root device. Designated: The port is designated if it can send the best BPDU on the segment to which it is connected. Alternate: The alternate port receives more useful BPDU from another bridge and is the blocked port. Backup: The backup port receives more useful BPDU from the same bridge and is the blocked port. Disabled: The function is disabled.

Port State Forwarding: The traffic can be forwarded through this port. Blocked: The traffic will be blocked. Disabled: The function is disabled.

Root Path Cost The total path cost to the root bridge.

Path Cost The path cost on this link.

Link Type Edge Port: The port is connected to an edge device. Point-to-Point Non Edge Port: The port is connected to another bridge and is full duplex. Shared Non Edge Port: The port is connected to another bridge and is half duplex.

BPDU Inconsistency BPDU is received on a port enabled by a BPDU guard.

Root Inconsistency A port is changed to a root port when enabled by a loop guard.

Loop Inconsistency A loop is detected on this port by a loop guard.

Page 111: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-96

Turbo Ring v2

Turbo Ring v2 Overview

Moxa Turbo Ring is a proprietary self-healing technology that enables fast fault recovery of under 20 ms for Fast Ethernet, and 50 ms for Gigabit Ethernet. Turbo Ring supports two topology expansions—ring coupling and dual-ring—to reduce redundant network cabling and network planning costs and to ensure high reliability of your industrial network applications.

The Turbo Ring v2 protocols identify one switch as the master of the network, and then automatically block one port beside master on the ring (red line) to avoid network’s redundant loops. In the event that one branch of the ring gets disconnected from the rest of the network, the protocol automatically readjusts the ring so that the part of the network that was disconnected can reestablish contact with the rest of the network.

How Turbo Ring v2 Works

Turbo Ring v2 is an advanced technology for network redundancy, which ensures recovery times of less than 20 ms for Fast Ethernet, and 50 ms for Gigabit Ethernet when the network is down. In addition, it allows more switches within the network rings. Users can select different network typologies for Turbo Ring redundancy to allow more network reliability and reduce cabling costs. Below are three examples of how Turbo Ring v2 works.

Ring Coupling Ring Coupling helps users separate distributed devices into different smaller redundant rings, but in such a way that the smaller rings at different remote sites will be able to communicate with each other. This is useful for applications where some devices are located at remote sites.

Page 112: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-97

Dual-Ring Dual-Ring adds reliability by using a single Moxa switch to connect two separate rings for applications that present cabling difficulties. It provides another ring coupling configuration where two adjacent rings can share one switch. This typology is an ideal solution for applications that have inherent cabling difficulties.

How to Determine the Redundant Path

For Turbo Ring v2, the master is determined by two methods, one is a system MAC address election, the smallest MAC address will play the Master role; the other is user manual configuration to enable Master role on the switch.

The redundant path is determined by "Ring Port 2", which means the port set on "Ring Port 2" will become the blocking port.

Ring Coupling for a “Turbo Ring V2” Ring

Page 113: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-98

For Turbo Ring V2, Ring Coupling is enabled by configuring the Coupling Port (Primary) on Switch B, and the Coupling Port (Backup) on Switch A only.

The Coupling Port (Backup) on Switch A is used for the backup path, and connects directly to an extra network port on Switch C. The Coupling Port (Primary) on Switch B monitors the status of the main path, and connects directly to an extra network port on Switch D. With ring coupling has been established, Switch A can activate the backup path as soon as it detects a problem with the main path.

ATTENTION

Ring Coupling needs to be enabled on one coupling primary switch and one coupling backup switch as the Ring Coupler. The Coupler must designate different ports as the two Turbo Ring ports and the coupling port.

NOTE You do not need to use the same switch for both Ring Coupling and Ring Master.

Turbo Ring V2 Settings and Status

Click Turbo Ring V2 on the menu, and then select the Setting tab.

Configure the following setting.

Enable

Setting Description Factory Default Enabled Enable Turbo Ring V2. Disabled

Disabled Disable Turbo Ring V2.

When finished, click Apply to save your changes.

Ring Settings

In Ring Setting, click the edit icon.

Page 114: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-99

Configure the following settings. When finished, click Apply to save your changes.

Enable

Setting Description Factory Default Enabled Enable Ring Setting. Disabled

Disabled Disable Ring Setting.

Master

Setting Description Factory Default

Enabled Enable this Ring as the Master. Disabled

Disabled Disable this Ring as the Master.

Ring Port 1

Setting Description Factory Default Select the port from the list

Specify this port as the 1st redundant port. 1/1

Ring Port 2

Setting Description Factory Default

Select the port from the list

Specify this port as the 2nd redundant port. 1/2

Ring Coupling Overview

Ring Coupling helps users separate distributed devices into different smaller redundant rings, but in such a way that the smaller rings at different remote sites will be able to communicate with each other. This is useful for the applications where some devices are located at remote sites.

Ring Coupling Settings and Status

In the Ring Coupling Setting, click the edit icon.

Page 115: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-100

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Ring Coupling. Disabled

Disabled Disable Ring Coupling.

Coupling Mode

Setting Description Factory Default

Coupling Backup Path Select Coupling Mode to assign the coupling port as the backup path.

Coupling Primary Path

Coupling Primary Path Select Coupling Mode to assign the coupling port as the primary path.

Coupling Port

Setting Description Factory Default Select the port from the list

Select the port as the coupling port. 2/1

When finished, click Apply to save your changes.

Page 116: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-101

Ring Settings and Ring Coupling Setting Status

Click Status in the Turbo Ring V2 menu to view the current Ring settings and the Ring Coupling Status.

Refer to the following table for a detailed description for each item of the Ring status.

Item Description

Ring ID The ID number of the Ring.

Master ID The MAC address of the Ring Master.

Status Healthy: The Ring and the ports are working properly. Break: One or more Rings have been broken.

Master The device is Master/Slave on this Ring.

Ring Port 1 The port of the first Ring port.

Ring Port 2 The port of the second Ring port.

Refer to the following table for a detailed description for the status of Coupling Mode and Coupling Port.

Item Description Coupling Mode Primary: The main path of Ring Coupling.

Backup: The backup path of Ring Coupling.

Coupling Port The port of the Ring Coupling.

Page 117: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-102

Turbo Chain

Turbo Chain Overview

Moxa’s Turbo Chain is an advanced software technology that gives network administrators the flexibility of constructing any type of redundant network topology. In addition, it offers system recovery time under 20 ms for Fast Ethernet, and 50 ms for Gigabit Ethernet for member port link environments. When using the “chain” concept, you first connect the Ethernet switches in a chain and then simply link the two ends of the chain to an Ethernet network.

Turbo Chain can be used on industrial networks that have a complex topology. If the industrial network uses a multi-ring architecture, Turbo Chain can be used to create flexible and scalable topologies with a fast media-recovery time.

How Turbo Chain Works

Moxa’s Turbo Chain outperforms traditional ring topologies by providing great flexibility, unrestricted expansion, and cost-effective configurations when connecting separate redundant rings together—in a simplified manner. With Turbo Chain, you can create any complex redundant network that correspond to your needs, while still ensuring great reliability and availability for your industrial Ethernet network applications.

With Moxa's Turbo Chain, network engineers have the flexibility to construct any type of redundant topology with minimum effort-by simply linking Turbo Chain to the Ethernet Network. Turbo Chain allows for

unrestricted network expansion. Network engineers no longer need to go through the hassle of reconfiguring the existing network, and can simply use Turbo Chain to scale up their redundant networks.

Page 118: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-103

How to Determine the Redundant Path

Here is an example of how to set up Turbo Chain and determine the redundant path.

1. Select the Head switch, Tail switch, and Member switches. 2. Configure one port as the Head port and one port as the Member port in the Head switch, configure one port

as the Tail port and one port as the Member port in the Tail switch, and configure two ports as Member ports in each of the Member switches.

3. Connect the Head switch, Tail switch, and Member switches as shown in the diagram below.

The path connecting to the Head port is the main path, and the path connecting to the Tail port is the backup path of Turbo Chain. Under normal conditions, packets are transmitted through the Head Port to the LAN network. If any Turbo Chain path is disconnected, the Tail Port will be activated so that packet transmission can continue.

There are two points to note:

1. Two Chain ports must have the same PVID.

2. Chain ports must join the untagged members of PVID VLAN before being assigned to be a Chain port.

Turbo Chain V2 Settings and Status

First select Turbo Chain on the menu and then click Setting.

Page 119: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-104

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Turbo Chain. Disabled

Disabled Disable Turbo Chain.

Chain Role

Setting Description Factory Default

Head Enable chain role as the Head. Member

Member Enable chain role as a Member.

Tail Enable chain role as the Tail.

Head/Member/Tail Port

Setting Description Factory Default

Select the port from the list

Specify the port as the Head/Member/Tail port. 1/1

Member Port

Setting Description Factory Default Select the port from the list

Specify the port as the member port. 1/2

When finished, click Apply to save your changes.

Select Turbo Chain on the menu and click Status to view the current Turbo Chain status.

Refer to the following table for a detailed description of each item.

Item Description Turbo Chain Head: The device is the head of this chain.

Member: The device is a member of this chain. Tail: The device is the tail of this chain.

Chain Role Healthy: The Chain and the ports are working properly. Break: The chain or the ports are broken.

Head/Member/Tail 1 Port Status The status of the first Head/Member/Tail port.

Head/Member/Tail 2 Port Status The status of the second Head/Member/Tail port.

Page 120: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-105

Dual Homing

Dual Homing Overview

Dual Homing is a layer 2 function, which uses a single Ethernet switch to connect two network topologies, both of which can run any redundancy protocols. It involves coupling two separate devices or even coupling to two separate rings with a single switch connecting to two independent connection points. The secondary path will be activated if the primary path fails.

How Dual Homing Works

Dual Homing is a redundant path technology that allows a single switch to connect to any topology.

The primary and secondary paths require manual configuration: Select a primary port as the primary path and the secondary port as the secondary path. The default path switching mode is "primary path always first", which means when failover occurs, the primary path will switch to the secondary path, but if the primary path recovers, the path will switch back to the primary path again even if the secondary path is healthy.

Path Switching Mode There are two path switch modes that users can configure:

Primary path always first: Always selects the path switching mode as the primary path first. When path switching occurs, the primary path will always be the first path for data communication.

Maintain current path: Select the path switching mode to maintain the current path. When path switching occurs, maintain the current path to keep the network stable and do not change paths for data communication.

Page 121: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-106

Dual Homing Settings and Status

Click Dual Homing in the menu and select Setting.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Dual Homing. Disabled

Disabled Disable Dual Homing.

Primary Port

Setting Description Factory Default

Select the port from the list

Specify the port as the primary port. 1/1

Secondary Port

Setting Description Factory Default Select the port from the list

Specify the port as the secondary port. 1/1

Path Switching Mode

Setting Description Factory Default Primary path always first

Always selects path switching mode as the primary path first. Primary path always first

Maintain current path Always selects the path switching mode to maintain the current path.

When finished, click Apply to save your changes.

Page 122: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-107

First, click Dual Homing in the menu and then select Status to view the current Dual Homing Settings.

Refer to the following table for a detailed description of each item.

Item Description

Path Primary: The primary path of dual homing. Secondary: The secondary path of dual homing.

Port The port that is used as the primary/secondary path.

Link Status Link Up: The port is connected. Link Down: The port is disconnected.

Port State Forwarding: The port is forwarding traffic. Blocking: The port is blocking traffic.

Management This section describes how to configure Network Management including SNMP and SNMP Trap/Inform.

Network Management This section demonstrates how to configure SNMP and SNMP Trap/Inform settings.

Page 123: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-108

SNMP

Moxa switches support SNMP V1, V2c, and V3. SNMP V1 and SNMP V2c use a community string match for authentication, which means that SNMP servers access all objects with read-only or read/write permissions using the community strings public and private by default. SNMP V3 requires that you select an authentication level of MD5 or SHA. You can also enable data encryption to enhance data security.

Supported SNMP security modes and levels are shown in the table below. Select the security mode and level that will be used to communicate between the SNMP agent and manager.

Protocol Version

UI Setting Authentication Encryption Method

SNMP V1, V2c

V1, V2c Read Community

Community string No Uses a community string match for authentication.

V1, V2c Write/Read Community

Community string No Uses a community string match for authentication.

SNMP V3 None No No Uses an account with admin or user to access objects.

MD5 or SHA Authentication based on MD5 or SHA

Disabled Uses authentication based on HMAC-MD5, or HMAC-SHA algorithms. 8-character passwords are the minimum requirement for authentication.

MD5 or SHA Authentication based on MD5 or SHA

Data encryption key: DES, AES

Uses authentication based on HMAC-MD5 or HMAC-SHA algorithms, and data encryption key. 8-character passwords and a data encryption key are the minimum requirements for authentication .and encryption.

General Settings

First click SNMP on the menu and then click General.

Configure the following settings.

SNMP Version

Setting Description Factory Default V1, V2c, V3 Specify V1, V2c, and V3 as the SNMP version. V1, V2c

V1, V2c Specify V1 and V2c as the SNMP version.

V3 only Specify V3 as the SNMP version.

Page 124: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-109

Read Community

Setting Description Factory Default Max. 30 characters Specifies the community string to authenticate the SNMP agent

for read-only access. The SNMP agent will access all objects with read-only permissions using this community string.

public

Read/Write Community

Setting Description Factory Default Max. 30 characters Specifies the community string to authenticate the SNMP agent

for read/write access. The SNMP server will access all objects with read/write permissions using this community string.

private

When finished, click Apply to save your changes.

Creating an SNMP Account

Click SNMP on the menu and then click the SNMP Account. Next click the + icon on the page.

Configure the following settings.

Username

Setting Description Factory Default

At least 4 characters, (max. 32 characters)

Input a username. None

Page 125: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-110

Authority

Setting Description Factory Default Read Write The user has read/write access. None

Read Only The user only has read access.

Authentication type

Setting Description Factory Default

None No authentication will be used. None

MD5 MD5 is the authentication type.

SHA SHA is the authentication type.

Authentication password

Setting Description Factory Default

8 to 64 characters Input the authentication password. None

Encryption Method

Setting Description Factory Default Disabled Disable the encryption method. None

DES DES is the encryption method.

AES AES is the encryption method.

Encryption Key

Setting Description Factory Default 8 to 30 characters Enable data encryption. None

When finished, click Create.

Deleting an Existing SNMP Account

To delete an existing SNMP account, select the delete icon on the account.

Click Delete to delete the SNMP account.

Page 126: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-111

SNMP Trap/Inform

General Settings

First select SNMP Trap/Inform on the menu and then click General.

Configure the following settings.

Retry

Setting Description Factory Default 1 to 99 Input the retry value. 3

Timeout

Setting Description Factory Default 1 to 300 Input the timeout value. 10

When finished, click Apply to save your changes.

SNMP Trap Host Settings

SNMP Trap allows an SNMP agent to notify the NMS of a significant event. The switch supports two SNMP modes: Trap mode and Inform mode. Click SNMP Trap/Inform on the menu, and then click SNMP Trap Host. Then select the + icon on the page.

Page 127: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-112

Configure the following settings.

Host IP/Name

Setting Description Factory Default Input a host IP or name, (max. 32 characters)

Specify the name of the primary trap server used by your network.

None

Mode

Setting Description Factory Default Trap V1 Set the trap version to Trap V1. None

Trap V2c Set the trap version to Trap v2c.

Inform V2c Set the inform version to Inform V2c.

Trap V3 Set the trap version to Trap V3.

Inform V3 Set the inform version to Inform V3.

Trap Community

Setting Description Factory Default At least 4 characters, (max. 30 characters)

Specify the community string that will be used for authentication.

None

When finished, click Create.

SNMP Trap Account Settings

Click SNMP Trap/Inform on the menu, and then click SNMP Trap Account. Next click the + icon on the page.

Page 128: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-113

Configure the following settings

Username

Setting Description Factory Default At least 4 characters, (max. 30 characters)

Input a username. None

Authentication type

Setting Description Factory Default None No authentication type will be used. None

MD5 MD5 is the authentication type.

SHA SHA is the authentication type.

Authentication Password

Setting Description Factory Default 8 to 64 characters Input the authentication password. None

Encryption Method

Setting Description Factory Default

Disabled Disable the encryption method. None

DES DES is the encryption method.

AES AES is the encryption method.

Encryption Key

Setting Description Factory Default

8 to 64 characters Enable data encryption. None

When finished, click Create.

Security This section describes how to configure Device Security, Network Security, and Authentication.

Page 129: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-114

Device Security This section includes information about the Management Interface, Login Policy, Trusted Access, and SSH & SSL configurations.

Management Interface

Click Management Interface on the menu.

Configure the following settings.

HTTP

Setting Description Factory Default Enabled Enable the HTTP connection. Enabled

Disabled Disable the HTTP connection.

Page 130: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-115

HTTP – TCP Port

Setting Description Factory Default 0 to 47808 Specify the HTTP connection port number. 80

HTTPS

Setting Description Factory Default Enabled Enable the HTTPS connection. Enabled

Disabled Disable the HTTPS connection.

HTTPS – TCP Port

Setting Description Factory Default 1 to 65535 Specify the HTTP connection port number. 443

Telnet

Setting Description Factory Default Enabled Enable a Telnet connection. Enabled

Disabled Disable a Telnet connection.

Telnet – TCP Port

Setting Description Factory Default 1 to 65535 Specify the Telnet connection port number. 23

SSH

Setting Description Factory Default Enabled Enable the SSH connection. Enabled

Disabled Disable the SSH connection.

SSH – TCP Port

Setting Description Factory Default 1 to 65535 Input the SSH connection port number. 22

SNMP

Setting Description Factory Default Enabled Enable the SNMP connection. Enabled

Disabled Disable the SNMP connection.

SNMP – Port

Setting Description Factory Default 0 to 47808 Input the SNMP connection port number. 161

Moxa Service

Setting Description Factory Default Enabled Enable Moxa Service. Enabled

Disabled Disable Moxa Service.

NOTE Moxa Service is only for Moxa network management software suite.

Moxa Service (Encrypted) – TCP Port

Setting Description Factory Default 443 (read only) Enable a Moxa Service TCP port. 443

Moxa Service (Encrypted) – UDP Port

Setting Description Factory Default 40404 (read only) Enable a Moxa Service UDP port. 40404

Page 131: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-116

Maximum number of Login Sessions for HTTP

Setting Description Factory Default 1 to 10 Specify the maximum amount of HTTP login sessions that can

happen at the same time. 5

Maximum number of Login Sessions for Telnet

Setting Description Factory Default 1 to 5 Specify the maximum amount of Telnet login sessions that can

happen at the same time. 1

When finished, click Apply to save your changes.

Login Policy

Click Login Policy on the menu.

Configure the following settings.

Login Message

Setting Description Factory Default

0 to 500 characters Input the message that will be displayed to users when they log in.

None

Login Authentication Failure Message

Setting Description Factory Default 0 to 500 characters Input the message that will be displayed when users fail to log

in. None

Account Login Failure Lockout

Setting Description Factory Default Enabled Enable the lockout function when a user fails to log in. Disabled

Disabled Disable the lockout function when a user fails to log in.

Page 132: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-117

Retry Failure Threshold (times)

Setting Description Factory Default 1 to 10 Input the maximum number of retry failure times. 5

Lockout Time (min.)

Setting Description Factory Default 1 to 60 Specify the amount of times log in credentials can be entered

incorrectly before the user is logged out. 5

Auto Logout Setting (min.)

Setting Description Factory Default

0 to 1440 Specify how long a user has to be inactive before getting logged out.

5

When finished, click Apply to save your changes.

Trusted Access

Trusted Access Overview

Trusted Access is a mechanism that provides a secure connection to Moxa’s switch. Users can use this method to allow the connection from the assigned IP address to ensure safe data transmission.

Trusted Access Settings and Status

Click Trusted Access on the menu.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Trusted Access. Disabled

Disabled Disable Trusted Access.

NOTE 1. Trusted Access has to be added before it can be enabled.

2. In order to avoid being disconnected after you enable Trusted Access, you must first add the current IP subnet to Trusted Access. In order to use this function, you should use an RS-232 console to log in or set the device to factory default.

When finished, click Apply to save your changes.

Page 133: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-118

Next, click the + icon.

Configure the following settings.

IP Address

Setting Description Factory Default Input IP address Specify the IP address that is allowed to connect to Moxa’s

switch. None

Netmask

Setting Description Factory Default Input Netmask Specify the Netmask that is allowed to connect to Moxa’s

switch. None

When finished, click Create.

You can view the Trusted Access status on the figure below.

To delete the trusted access source, select the item and then click the delete icon on the top of the page.

Click Delete to delete the item.

Page 134: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-119

SSH & SSL

SSH Key Regeneration

Click SSH & SSL on the menu and then select the SSH tab.

Click Regenerate to regenerate the key.

SSL Certification Regeneration

Click SSH & SSL on the menu and select the SSL tab. The Certificate Information is shown on this screen.

Configure the following settings.

Export SSL Certificate Request

Setting Description Factory Default Export Export the SSL certificate to your local computer. None

Regenerate SSL Certificate

Setting Description Factory Default Regenerate Regenerate the SSL certificate. None

Page 135: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-120

Import Certificate

Setting Description Factory Default Select the file Import the SSL certificate from the location where the SSL

certificate is located. None

Network Security This section demonstrates how to configure network security settings, including IEEE802.1X, Port Security, and Traffic Storm Control.

IEEE 802.1X

Port-based IEEE 802.1X Overview

The IEEE 802.1X standard defines a protocol for client/server-based access control and authentication. The protocol restricts unauthorized clients from connecting to a LAN through ports that are open to the Internet, and which otherwise would be readily accessible. The purpose of the authentication server is to check each client that requests access to the port. The client is only allowed access to the port if the client’s permission is authenticated.

Three components are used to create an authentication mechanism based on 802.1X standards: Client/Supplicant, Authentication Server, and Authenticator.

Client/Supplicant: The end station that requests access to the LAN and switch services and responds to the requests from the switch.

Authentication Server: The server that performs the actual authentication of the supplicant.

Authenticator: Edge switch or wireless access point that acts as a proxy between the supplicant and the authentication server, requesting identity information from the supplicant, verifying the information with the authentication server, and relaying a response to the supplicant.

The Moxa switch acts as an authenticator in the 802.1X environment. A supplicant and an authenticator exchange EAPOL (Extensible Authentication Protocol over LAN) frames with each other. We can either use an external RADIUS server as the authentication server or implement the authentication server in the Moxa switch by using a Local User Database as the authentication look-up table. When we use an external RADIUS server as the authentication server, the authenticator and the authentication server exchange EAP frames.

Authentication can be initiated either by the supplicant or the authenticator. When the supplicant initiates the authentication process, it sends an EAPOL-Start frame to the authenticator. When the authenticator initiates the authentication process or when it receives an EAPOL Start frame, it sends an EAP Request/Identity frame to ask for the username of the supplicant.

Page 136: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-121

How IEEE 802.1X Works

802.1X authentication requires three parties: a supplicant, an authenticator, and an authentication server. The supplicant is a client device that wishes to connect to the LAN or WLAN. The supplicant can also use the software to run on the client that offers credentials to the authenticator. Network administrators usually use an Ethernet switch or wireless access point as the authenticator, and running software supporting RADIUS and EAP protocols in the authentication server.

The authenticator serves as a security guard to a protected network. The supplicant is not allowed access through the authenticator to the protected side of the network unless the supplicant’s identity has been validated and authorized. With 802.1X port-based authentication, the supplicant provides credentials, such as user name/password or digital certificate, to the authenticator, and the authenticator transmits the credentials to the authentication server for verification. If the authentication server approves the credentials as valid, the supplicant (client device) is allowed to access resources located on the protected side of the network.

IEEE 802.1X Settings

Click IEEE802.1X on the menu and then select the General tab.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable IEEE 802.1X. Disabled

Disabled Disable IEEE 802.1X.

Authentication Mode

Setting Description Factory Default

Local Database Use the local database as the authentication mode. Local Database

RADIUS Use the RADIUS as the authentication mode.

When finished, click Apply to save your changes.

Page 137: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-122

To configure the IEEE 802.1X settings for the specific port, click the edit icon on the port.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable IEEE 802.1X. Disabled

Disabled Disable IEEE 802.1X.

Page 138: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-123

Port Control

Setting Description Factory Default Force Unauthorized The controlled port has to be held in the Unauthorized state. Auto

Auto The controlled port is set to the authorized or unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the Authentication Server.

Force Authorized The controlled port is required to be held in the authorized state.

Max Request (times)

Setting Description Factory Default 1 to 10 Enable re-authentication request time. 2

Quiet Period (sec.)

Setting Description Factory Default 0 to 65535 Specify the duration of time that the switch remains in the quiet

state following a failed authentication exchange with the client. 60

Reauthentication

Setting Description Factory Default

Enabled Enable re-authentication. Disabled

Disabled Disable re-authentication.

Reauth Period (sec.)

Setting Description Factory Default 1 to 65535 Input the duration of time between re-authentication attempts. 3600

Server Timeout (sec.)

Setting Description Factory Default

1 to 65535 Input the duration of time that the switch will re-transmit the packets from the switch to the authentication server.

30

Supp (Supplicant, such as Client PC) Timeout (sec.)

Setting Description Factory Default 1 to 65535 Input the duration of time that the switch will re-transmit the

packets from the switch to the client. 30

Tx Period (sec.)

Setting Description Factory Default 1 to 65535 Input the duration of time that the switch will re-transmit the

data to the client. 30

Copy Config to Ports

Setting Description Factory Default

Select the port(s) from the drop-down list

Allows users to copy configurations to other port(s). None

When finished, click Apply to save your changes.

Page 139: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-124

IEEE 802.1X Database

RADIUS

RADIUS Remote Authentication Dial in User Service is a protocol that involves three services in one network protocol: Authentication, Authorization, and Accounting (AAA). The protocol operates on port 1812, and the AAA management for users connecting to a network service.

RADIUS is based on a client/server protocol that runs in the application layer, and can use either TCP or UDP as the mode of transport. The network access servers that contain the RADIUS protocol can allow the client to communicate with the RADIUS server. Through Authentication, Authorization, and Accounting, RADIUS is used to monitor access to the network.

To configure RADIUS settings, click the RADIUS tab.

Configure the following settings.

Server Address 1

Setting Description Factory Default To input server address 1

Specify the 1st server address. None

Auth Port

Setting Description Factory Default 1 to 65535 Specify the authentication port number for the 1st server

address. None

Share Key

Setting Description Factory Default

Input the share key for the 1st server, (0 to 46)

Specify the share key for the 1st server. None

Page 140: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-125

Timeout (sec.)

Setting Description Factory Default 1 to 120 Specify the duration of time before a device is logged out. None

Retransmit (sec.)

Setting Description Factory Default 1 to 254 Specify the time for data re-transmission. None

Server Address 2

Setting Description Factory Default

To input server address 2

Specify the 2nd server address. None

Auth Port

Setting Description Factory Default 1 to 65535 Specify the authentication port number for the 1st server

address. None

Share Key

Setting Description Factory Default Input the share key for the 2nd server (0 to 46)

Specify the share key for the 2nd server. None

Timeout

Setting Description Factory Default

1 to 120 Specify the duration of time before the device is timed out. None

Retransmit (sec.)

Setting Description Factory Default 1 to 254 Specify the time for data re-transmission. None

When finished, click Apply to save your changes.

NOTE The RADIUS service will be operated via the 1st server first; if it fails, it will be run on the 2nd server.

Local Database

First click the Local Database tab and then click the + icon.

Page 141: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-126

Configure the following settings.

Username

Setting Description Factory Default 0 to 20 characters Specify the username for the local database. None

Password

Setting Description Factory Default At least 4 characters, (max. 64 characters)

Specify the password for the local database user. None

Confirm Password

Setting Description Factory Default

At least 4 characters, (max. 64 characters)

Confirm the password for the local database user. None

When finished, click Apply to save your changes.

Port Security

MAC Sticky Overview

MAC Sticky is a function that allows users to configure the maximum number of MAC addresses (the Limit) that a port can “learn”. Users can configure what action should be taken (under Secure Action) when a new MAC address tries to access a port after the maximum number of MAC addresses have already been learned. The total number of allowed MAC addresses cannot exceed 1024.

How MAC Sticky Works

In MAC Sticky mode, administrators can set a proper limit number and then configure trust devices manually, or let the system configure trust devices automatically. Except for dropping packets as a response to any violations, administrators can set ‘port shutdown’ on a port and achieve a strict security guarantee. When a violation is registered on a port, the port will shut down and an administrator will receive a notification to perform a check.

Page 142: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-127

MAC Sticky Settings and Status

To configure the MAC Sticky settings, select the General tab in Port Security.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable port security. Enabled

Disabled Disable port security.

Port Security Mode

Setting Description Factory Default

MAC Sticky Specify MAC Sticky as the port security mode. Static Port Lock

Static Port Lock Specify Static Port Lock as the port security mode.

Select MAC Sticky and click Apply.

NOTE When you change the Port Security Mode, the settings in the table will be deleted.

Click the edit icon on the port you want to edit.

Page 143: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-128

Configure the following settings.

MAC Sticky

Setting Description Factory Default Enabled Enable Static Port Lock for this port. Disabled

Disabled Disable Static Port Lock for this port.

Address Limit

Setting Description Factory Default

1 to 997 Specify the maximum numbers of the learned MAC address. 1

Secure Action

Setting Description Factory Default Port Shutdown Enable port shutdown when a violation occurs. Packet Drop

Packet Drop Drop the packets when a violation occurs.

When finished, click Apply to save your changes. Next, click the MAC Sticky tab, and then click the + icon to add the MAC Sticky entries.

Page 144: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-129

Configure the following settings.

Port

Setting Description Factory Default Select the port from the drop-down list

Select the port(s) that will be used with the MAC Sticky function.

None

VLAN ID

Setting Description Factory Default Input the VLAN ID Specify the VLAN ID that will be used with MAC Sticky. None

MAC Address

Setting Description Factory Default

Input the MAC address that will be used

Specify the MAC Address of the device that will be used as the reliable source for network access.

None

When finished, click Create.

You can view the MAC Sticky settings in the figure below.

Page 145: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-130

Static Port Lock Overview

To provide a port-based security function, Moxa’s switches have implemented Static Port Lock function; the main idea is to allow configured devices, 128 at most, to access the network through a specific port. Packets sent from unknown devices or from configured devices with mismatching ports will be dropped. In other words, only the packets from the devices pre-configured with the specific MAC addresses can be sent to the specific port to ensure a secured network data transmission scenario.

Static Port Lock Settings and Status

To configure these setting, first click the Port Security tab and then click General.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable port security. Enabled

Disabled Disable port security.

Port Security Mode

Setting Description Factory Default

MAC Sticky Select MAC Sticky as the port security mode. Static Port Lock

Static Port Lock Select Static Port Lock as the port security mode.

Select Static Port Lock and click Apply.

Select the edit icon on the port you want to edit.

Page 146: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-131

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Static Port Lock. Disabled

Disabled Disable Static Port Lock.

When finished, click Apply to save your changes. Next, click the Static Port Lock tab and then the + icon to perform further settings.

Configure the following settings.

Port

Setting Description Factory Default

Select the port from the drop-down list

Specify the port(s) that will be used with Static Port Lock. None

Page 147: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-132

VLAN ID

Setting Description Factory Default Input the VLAN ID Specify the VLAN ID that will use Static Port Lock. None

MAC Address

Setting Description Factory Default Input the MAC address that will be used

Specify the MAC Address of the device that will be used as the reliable source for network access.

None

When finished, click Create.

You can view the Static Port Lock setting status from the following figure.

Traffic Storm Control

A traffic storm can happen when packets flood the network; this causes excessive traffic and slows down the network performance. To counter this, Traffic Storm Control provides an efficient design to prevent the network from flooding caused by a broadcast, multicast, or unicast traffic storm on a physical network layer. The feature can handle packets from both ingress and egress data.

First click Traffic Storm Control on the menu, and then click the edit icon on the specific port you want to configure.

Page 148: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-133

Configure the following settings.

There are three methods that can be used for traffic storm control: Broadcast, Multicast, and Destination Lookup Failure (DLF).

Broadcast

Setting Description Factory Default Enabled Enable Broadcast when a traffic storm occurs. Disabled

Disabled Disable Broadcast when a traffic storm occurs.

Multicast

Setting Description Factory Default

Enabled Enable multicast when a traffic storm occurs. Disabled

Disabled Disable multicast when a traffic storm occurs.

DLF

Setting Description Factory Default Enabled Enable DLF when a traffic storm occurs. Disabled

Disabled Disable DLF when a traffic storm occurs.

Threshold (fps)

Setting Description Factory Default 1 to 1488100 Define the threshold for a traffic storm. 12700

Copy Config to Ports

Setting Description Factory Default Select the port(s) from the drop-down list

Select the port(s) you want to have the same configurations for.

None

When finished, click Apply to save your changes.

Page 149: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-134

Authentication This section describes how to configure system authentication including RADIUS and TACACS+. Moxa switches have three different user login authentications: TACACS+ (Terminal Access Controller Access-Control System Plus), RADIUS (Remote Authentication Dial In User Service), and Local. The TACACS+ and RADIUS mechanisms are centralized “AAA” (Authentication, Authorization, and Accounting) systems for connecting to network services. The fundamental purpose of both TACACS+ and RADIUS is to provide an efficient and secure mechanism for user account management.

There are five combinations available for users to choose from:

1. TACACS+, Local: Check the TACACS+ database first. If checking the TACACS+ database fails, then check the Local database.

2. RADIUS, Local: Check the RADIUS database first. If checking the RADIUS database fails, then check the Local database.

3. TACACS+: Only check TACACS+ database. 4. RADIUS: Only check the RADIUS database. 5. Local: Only check the Local database.

This section includes the configurations for Login Authentication, RADIUS, and TACACS+.

Login Authentication This section allows users to select the login authentication protocol.

Select Login Authentication.

Configure the following settings.

Authentication Protocol

Setting Description Factory Default Local Select Local as the authentication protocol. Local

RADIUS Select RADIUS as the authentication protocol.

TACACS+ Select TACACS+ as the authentication protocol.

RADIUS, Local Select RADIUS and Local as the authentication protocol.

TACACS+, Local Select TACACS+ and Local as the authentication protocol.

When finished, click Apply to save your changes.

Page 150: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-135

RADIUS

Click RADIUS on the menu and configure the following settings.

Server Address 1

Setting Description Factory Default Input the server address

Specify the 1st server address as the authentication database. 0.0.0.0

UDP Port

Setting Description Factory Default Input the port number Specify the UDP port. 1812

Share Key

Setting Description Factory Default

Input the key Input the share key for 1st server authentication verification. None

Authentication Type

Setting Description Factory Default PAP PAP is the authentication type. CHAP

CHAP CHAP is the authentication type.

MS-CHAPv1 MS-CHAPv1 is the authentication type.

Timeout (sec.)

Setting Description Factory Default 5 to 180 When waiting for a response from the server, set the amount of

time before timeout. 5

Page 151: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-136

Retry (sec.)

Setting Description Factory Default 0 to 5 Define the retry interval when trying to reconnect to a server. 1

Server Address 2

Setting Description Factory Default Input the server address

Specify the 2nd server address as the authentication database. 0.0.0.0

UDP Port

Setting Description Factory Default

Input the port number Specify the UDP port. 1812

Share Key

Setting Description Factory Default Input the key Specify the share key for 2nd server authentication verification. None

Authentication Type

Setting Description Factory Default PAP PAP is the authentication type. CHAP

CHAP CHAP is the authentication type.

MS-CHAPv1 MS-CHAPv1 is the authentication type.

Timeout (sec.)

Setting Description Factory Default 5 to 180 When waiting for a response from the server, set the amount of

time before the device is timed out. 5

Retry (sec.)

Setting Description Factory Default

0 to 5 Set the retry interval when trying to reconnect to a server. 1

When finished, click Apply to save your changes.

NOTE The RADIUS service will be operated via the 1st server; if it fails, it will run on the 2nd server.

Page 152: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-137

TACACS+

Click TACACS+ on the menu and then configure the following settings.

Server Address 1

Setting Description Factory Default Input the server address

Specify the 1st server address as the authentication database. 0.0.0.0

TCP Port

Setting Description Factory Default Input the port number Specify the UDP port. 49

Share Key

Setting Description Factory Default

Input the key Specify the share key for 1st server authentication verification. None

Authentication Type

Setting Description Factory Default ASCII ASCII is the authentication type. CHAP

PAP PAP is the authentication type.

CHAP CHAP is the authentication type.

Timeout (sec.)

Setting Description Factory Default Input the value When waiting for a response from the server, set the amount of

time before the device is timed out. 5

Page 153: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-138

Retry

Setting Description Factory Default Input the value Set the retry interval when trying to reconnect to a server. 1

Server Address 2

Setting Description Factory Default Input the server address

Specify the 2nd server address as the authentication database. 0.0.0.0

TCP Port

Setting Description Factory Default

Input the port number Specify the UDP port. 49

Share Key

Setting Description Factory Default Input the key Specify the share key for 2nd server authentication verification. None

Authentication Type

Setting Description Factory Default ASCII ASCII is the authentication type. CHAP

PAP PAP is the authentication type.

CHAP CHAP is the authentication type.

Timeout (sec.)

Setting Description Factory Default Input the value When waiting for a response from the server, set the amount of

time before the device is timed out. 5

Retry

Setting Description Factory Default

Input the value Set the retry interval when trying to reconnect to a server. 1

When finished, click Apply to save your changes.

NOTE The TACACS+ service will be operated via the 1st server; if it fails, it will run on the 2nd server.

Diagnostics This section describes the diagnostics functions of Moxa’s switch. Click Diagnostics on the function menu.

Page 154: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-139

System Status This section allows users to view the current system status including Utilization, Statistics, and Module Information.

Utilization

Click Utilization on the function menu to view the current utilization status including CPU utilization, memory history, power consumption, and power history. All of the information is displayed via graphics, making it easier for users to view the system status. In addition, a refresh icon is available on the upper right corner of each figure, which allows users to view the latest status for each function.

CPU Utilization

Setting Description Factory Default Read-only Displays the current utilization of the CPU. None

CPU Usage History

Setting Description Factory Default Read-only Displays the CPU usage history trend in a chart. None

Page 155: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-140

Memory Utilization

Setting Description Factory Default Read-only Displays the memory status. None

Memory Usage History

Setting Description Factory Default Read-only Displays the history of the memory usage. None

Power Consumption (watt)

Setting Description Factory Default

Read-only Displays the power consumption status. None

Power Usage History

Setting Description Factory Default Read-only Displays the history of the power usage. None

Statistics

Click Statistics on the function menu. The first figure shows the packet counter status.

The status of the different ports will be shown in different colors. A maximum of five ports will have their information displayed.

Page 156: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-141

There are four icons on the right upper corner of the page. The table below provides a description for each one.

Item Name Description

Refresh All statistical data will be refreshed.

Reset Statistics Graph The packet counter will be cleared and the graphs will be reset.

Display Setting All selected setting items will be shown here.

Data Comparison Select the data you want to compare.

Refreshing the Statistics

Click the Refresh button and all statistical data will be refreshed immediately.

Resetting Statistics Graph

Click the Reset button and select Clear to clear the packet counter and reset the graph.

Display Setting

Click the Display Setting icon and all settings will be displayed. You can select the display mode from the drop-down list.

Page 157: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-142

The Monitoring Port is the port you want to view or monitor. The sniffer port is the port that you can choose to view its receiving or transmission status or both.

Display Mode

Setting Description Factory Default Packet Counter The packet statistics will be displayed. Packet Counter

Bandwidth Utilization The bandwidth statistics will be displayed.

Click Apply to complete.

Comparing Data

Click the Data Comparison icon and then select the items from the relevant fields.

Click Close to complete.

The data comparison figure will be shown. Click Close to finish.

The detailed packet transmission activity for each port can be seen in the table below.

Page 158: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-143

Port: port number

Tx Total Octets: Number of octets transmitted including bad packets and FCS octets. Framing bits are not included.

Tx Total Packets: Number of packets transmitted.

Tx Unicast Packets: Number of Unicast packets transmitted.

Tx Broadcast Packets: Number of good Broadcast packets transmitted. Multicast packets are not included.

Rx Total Octets: Number of octets received, including bad packets and FCS octets. Framing bits are not included.

Rx Unicast Packets: Number of Unicast packets received.

Rx Multicast Packets: Number of Multicast packets received.

Rx Broadcast Packets: Number of good Broadcast packets received. Multicast packets are not included.

Rx Pause Packets: Number of pause packets received.

Collision Packets: Number of collisions received. If Jumbo Frames are enabled, the threshold of Jabber Frames is raised to the maximum size of Jumbo Frames.

Late Collision Packets: Number of late collision packets.

Excessive Collision Packets: Number of excessive collision packets.

CRC Align Error Packets: Number of CRC and Align errors that have occurred.

Drop Packets: Number of packets that were dropped.

Undersize: Number of undersized packets (less than 64 octets) received.

Oversize Packets: Number of oversized packets (over 1518 octets) received.

Fragment Packets: Number of fragments (packets with less than 64 octets, excluding framing bits, but including FCS octets) received.

Jabber Packets: Number of received packets that were longer than 1632 octets. This number excludes frame bits, but includes FCS octets that had either a bad FCS (Frame Check Sequence) with an integral number of octets (FCS Error) or a bad FCS with a non-integral octet (Alignment Error) number.

Page 159: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-144

Module Information

Click Module Information on the function menu to view the current module information of the switch.

For example, in the figure above, the MDS-G4028 switch is installed in Slot M1 and there is an LM-70000H-4GSFP module installed in Slot M3. In addition, a power module has been installed in Slot PWR2.

ATTENTION

When a different type of module has been inserted into the switch, we suggest you re-configure the settings, or use reset to default settings. When the same module is inserted into the slot, users do not need to re-configure the settings or use reset to default settings.

Event Notification This section includes the information regarding Event Notification, Relay Alarm Cut-off, Email Notification, and Syslog.

Page 160: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-145

Event Notification

There are two functions within Event Notification: System and Function, and Port.

In the Event Notification menu, click the System and Function tab, and then click the edit icon on the specific event you want to configure. For example, select the edit icon for warm start when the switch reboots.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Event Notification for this event. Enabled

Disabled Disable Event Notification for this event.

Registered Action

Setting Description Factory Default

Trap Send SNMP Trap for event notifications. Trap/Email

Email Send an email for event notifications.

MGMT Relay Trigger MGMT Relay for event notifications.

PWR1 Relay Trigger PWR1 Relay for event notifications.

PWR2 Relay Trigger PWR2 Relay for event notifications.

When finished, click Apply to save your changes.

Page 161: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-146

In addition, use the same method to edit other events, such as login lockout, warm start, password changed, etc.

Next, in the Event Notification menu, click the Port tab, and then click the edit icon on the specific port status on Event Name. For example, select the edit icon for event notifications when the port status is on.

Configure the following settings.

Enable

Setting Description Factory Default Enabled Enable Event Notification for this event. Enabled

Disabled Disable Event Notification for this event.

Registered Action

Setting Description Factory Default

Trap Send SNMP Trap for event notifications. Trap/Email

Email Send an email for event notifications.

MGMT Relay Trigger MGMT Relay for event notifications.

PWR1 Relay Trigger PWR1 Relay for event notifications.

PWR2 Relay Trigger PWR2 Relay for event notifications.

Page 162: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-147

Registered Port

Setting Description Factory Default Select port(s) from the drop-down list

Specify the port(s) that use the registered action. All Ports

When finished, click Apply to save your changes.

In addition, use the same method to edit other events such as, port status is off, port shutdown by port security, and port recovery by rate limit, etc.

Check the following table for the severity degree of each event.

System & Function Event Name Severity Cold start Critical

Warm start Notice

Configuration changed Notice

Login success Notice

Login fail Warning

Login lockout Warning

Account setting changed Notice

Configuration imported Notice

SSL certification changed Notice

Log capacity threshold Warning

Password changed Notice

PWR Off->On Notice

PWR On->Off Notice

DI On Notice

DI Off Notice

Topology changed Warning

Coupling changed Warning

Master changed Warning

Master mismatch Warning

RSTP topology changed Warning

RSTP root changed Warning

RSTP migration Warning

RSTP invalid BPDU Warning

RSTP new port role Warning

Redundant port health check fail Error

Dual homing path changed Warning

Dot1X auth fail Warning

LLDP table changed Information

RMON raising alarm Warning

RMON failing alarm Warning

PD power On Notice

PD power Off Notice

Low input voltage Warning

PD over current Error

PD no response Error

Over power budget limit Warning

Power detection failure Warning

Page 163: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-148

Port

Event Name Severity Port On Notice

Port Off Notice

Port shutdown by Port Security Warning

Port shutdown by Rate Limit Warning

Port recovery by Rate Limit Warning

Relay Output Overview

A relay is an electrically operated switch that often uses an electromagnet to mechanically operate a switch. Relays are used to control a circuit by a separate low-power signal, or where several circuits must be controlled by one signal. This is typically safe when the problem or malfunction occurs in a remote device.

Moxa’s switches offer three sets of relay outputs, one on the mainboard and two on the power modules, providing the secured protection of the remote switch and secure data communication. In addition, email notifications can also be sent to inform system administrators to perform further checks and maintenance.

Relay Output Settings and Status

To select Relay Output as the event notifications, click Relay Output on the function menu.

Relay Output

Setting Description Factory Default

MGMT Relay Trigger MGMT Relay for event notifications. None

PWR1 Relay Trigger PWR1 Relay for event notifications.

PWR2 Relay Trigger PWR2 Relay for event notifications.

When finished, click Apply to save your changes.

Page 164: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-149

Email Notification

Select Email Notification on the function menu and configure the following settings.

Mail Server

Setting Description Factory Default IP address or URL The IP Address or URL of the email server. 0.0.0.0

TCP Port

Setting Description Factory Default 1 to 65535 The TCP port number of your email server. 25

User Name

Setting Description Factory Default

Max. of 60 characters Your email account name. None

Password

Setting Description Factory Default Max. of 60 characters Your email account password. None

TLS Enable

Setting Description Factory Default Enabled Enable TLS (Transport Layer Security). Disabled

Disabled Disable TLS (Transport Layer Security).

Sender Address

Setting Description Factory Default Max. 60 characters The sender’s email address. admin@localhost

Page 165: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-150

1st to 5th Email Addresses

Setting Description Factory Default Max. of 60 characters You can set up to five email addresses to receive alert emails

from the Moxa switch. None

When finished, click Apply to save your changes.

Syslog Settings

Click Syslog on the function menu and configure the following settings.

Logging Enable

Setting Description Factory Default Enabled Enable logging. Disabled

Disabled Disable logging.

Syslog Server 1

Setting Description Factory Default Enabled Enable the 1st log server. Disabled

Disabled Disable the 1st log server.

Address 1

Setting Description Factory Default

IP Address Input the IP address of the Syslog 1st server that is used by your network.

None

UDP Port

Setting Description Factory Default 1 to 65535 Input the UDP port number. 514

Page 166: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-151

Syslog Server 2

Setting Description Factory Default Enabled Enable the 2nd syslog server. Disabled

Disabled Disable the 2nd syslog server.

Address 2

Setting Description Factory Default

IP Address Input the IP address of Syslog 2nd server that is used by your network.

None

UDP Port

Setting Description Factory Default 1 to 65535 Input the UDP port number. 514

Syslog Server 3

Setting Description Factory Default Enabled Enable the 3rd syslog server. Disabled

Disabled Disable the 3rd syslog server.

Address 3

Setting Description Factory Default IP Address Input the IP address of the Syslog 3rd server that is used by

your network. None

UDP Port

Setting Description Factory Default 1 to 65535 Input the UDP port number. 514

When finished, click Apply to save your changes.

NOTE If the syslog server cannot receive the previous logs, it is possible that the receiving port of the syslog server is not ready. We suggest you enable the Linkup Delay function to delay the log delivery time.

Diagnosis This section explains the configurations for system diagnoses such as LLDP, Port Mirror, Ping, ARP Table, and Event Log.

Page 167: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-152

LLDP Overview

LLDP is an OSI Layer 2 protocol defined by IEEE 802.11AB. LLDP standardizes the self-identification advertisement method, and allows each networking device, such as a Moxa managed switch, to periodically send its system and configuration information to its neighbors. Because of this, all LLDP devices are kept informed of each other’s status and configurations. With SNMP, this information can be transferred to Moxa’s MXview for auto-topology and network visualization.

From the switch’s web interface, you can enable or disable LLDP, and set the LLDP transmit interval. In addition, you can view each switch’s neighbor-list, which is reported by its network neighbors. Most importantly, enabling the LLDP function allows Moxa’s MXview to automatically display the network’s topology and system setup details, such as VLAN and Trunking for the entire network.

LLDP Settings and Status

Click LLDP on the menu and then select the Setting tab to configure the following settings.

Enable

Setting Description Factory Default Enabled Enable LLDP. Disabled

Disabled Disable LLDP.

Page 168: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-153

LLDP Version

Setting Description Factory Default Show the LLDP version Show the LLDP version automatically. 2005

Transmit Interval (sec.)

Setting Description Factory Default 5 to 32768 Set the transmit interval of LLDP messages 30

Notification Interval (sec.)

Setting Description Factory Default

5 to 3600 Specify the notification interval. 5

Tx Delay (sec.)

Setting Description Factory Default 1 to 8192 Specify the Tx delay interval. 2

Reinitialization Delay (sec.)

Setting Description Factory Default 1 to 10 Specify the LLDP reinitialization delay interval. 2

Holdtime Multiplier

Setting Description Factory Default

2 to 10 Specify the holdtime multiplier value. 4

Chassis ID Subtype

Setting Description Factory Default Chassis-Component Select Chassis-Component as Chassis ID subtype. Mac-Addr

If-Alias Select If-Alias as Chassis ID subtype.

Port-Component Select Port-Component as Chassis ID subtype.

MAC-Addr Select MAC-Address as Chassis ID subtype.

Network Address Select Network Address as Chassis ID subtype.

If-Name Select If-Name as Chassis ID subtype.

Local Select Local as Chassis ID subtype.

When finished, click Apply to save your changes. Each port for the LLDP settings can also be configured. Select the edit icon for the port you want to configure.

Page 169: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-154

Configure the following settings.

Port Status

Setting Description Factory Default Tx Only Set Tx as the port status. Tx and Rx

Rx Only Set Rx as the port status.

Tx and Rx Set both Tx and Rx as the port status.

Subtype

Setting Description Factory Default If-Alias Select If-Alias as the subtype. If-Alias

Port-Component Select Port-Component as the subtype.

MAC-Addr Select MAC-Address as the subtype.

If-Name Select If-Name as the subtype.

Local Select Local as the subtype.

TLV

Setting Description Factory Default

Basic Set TLV as Basic. Basic

802.1 Set TLV as 802.1.

802.3 Set TLV as 802.3.

Transmit TLVs

Setting Description Factory Default

Port Description Add a port description for the TLV. Port Description System Name System Name Add a system name for the TLV.

System Description Add a system description for the TLV.

System Capability Add a system capability for the TLV.

Page 170: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-155

Copy Config to Port

Setting Description Factory Default Select the port from the list

Copy the same configurations to other port(s). None

When finished, click Apply to save your changes. To view the LLDP status, click the Status tab on the LLDP page, and the status of all LLDP will be shown on the page.

Refer to the following table for the detailed description of each item.

Local Information Enable Show if LLDP has been enabled or disabled.

LLDP Version Show the LLDP version.

Chassis ID Subtype Show the chassis ID subtype.

Chassis ID Show the chassis ID.

Local Timer

Transmit Interval (sec.) The interval between regular LLDP packet transmissions.

Notification Interval (sec.) The interval that notifications will be sent.

Tx Delay (sec.) The delay period between successive LLDP frame transmissions initiated by changes.

Reinitialization Delay (sec.) The interval an LLDP port waits before re-initializing an LLDP packet transmission.

Holdtime Multiplier The amount of time that the receiving device holds an LLDP packet before discarding it.

Remote Table Statistics

Last Change Time (ms.) The last time the remote table changed.

Inserts How many inserts have occurred.

Drop How many drops have occurred.

Delete How many deletes have occurred.

Ageouts How many ageouts have occurred.

To view the LLDP status for a specific port, click the detailed information icon on the port. All information will be shown on the right side of the page.

Page 171: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-156

Port Mirroring

Port Mirroring Overview

The Port Mirroring function can be used to monitor data being transmitted through a specific port. This is done by setting up another port (the mirror port) to receive the same data being transmitted from, or both to and from, the port under observation. Using a mirror port allows the network administrator to sniff the observed port to keep tabs on network activity.

NOTE The MDS-G4000 Series allows up to five many-to-many port mirroring sessions. Please note the mirrored and mirroring port cannot be duplicated on each session.

How Port Mirror Works

Port Mirroring can configure to copy one or more packets from various ports to a single port, so that users can check if there are problems occurring in these ports. For example, the following figure demonstrates how the packets transmitted in the four mirrored ports (marked in orange) are copied (mirrored) to a single mirroring port (marked in green). These packets will be sent to a monitoring computer and then software is used to check if there is something wrong with these packets. It is a useful function to troubleshoot or debug a network data transmission issue.

Page 172: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-157

Port Mirror Settings and Status

Click Port Mirror on the menu and then configure the settings.

Enable

Setting Description Factory Default Enabled Enable Port Mirror. Enabled

Disabled Disable Port Mirror.

When finished, click Apply to save your changes.

To configure the specific port, click the edit icon next to the port.

NOTE A maximum of five port mirroring many-to-many port combinations can be enabled for each session.

Configure the following settings.

Page 173: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-158

Enable

Setting Description Factory Default Enabled Enable Port Mirror for this session. Disabled

Disabled Disable Port Mirror for this session.

Tx Source Port

Setting Description Factory Default

Select the port from the list

Select this option to monitor only those data packets being sent out through the switch’s port.

None

Rx Source Port

Setting Description Factory Default Select the port from the list

Select this option to monitor only those data packets coming into the switch’s port.

None

Destination Port

Setting Description Factory Default Select the port from the list

Specify this port as the destination port. None

When finished, click Apply to save your changes.

NOTE The RSTP ports and Port Mirror destination port cannot be enabled on the same port.

The Port Mirror status can be seen in the figure below.

Ping

The Ping function uses the ping command to give users a simple but powerful tool for troubleshooting network problems. The function most unique feature of the function is that even though the ping command is entered from the user’s PC, the actual ping command originates from the Moxa switch itself. This allows the user to essentially sit on top of the Moxa switch and send ping commands out through its ports.

To use the Ping function, click Ping on the menu, and enter the IP address or domain name you want to ping. After clicking Ping, the result will be shown.

Page 174: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-159

ARP Table

To view the ARP Table, select ARP Table and the information will be displayed.

Event Log

To edit the event log overseize-action, click Event Log on the menu, and then select Event Log on the page.

Configure the following settings when the event log file is full.

Oversize-Action

Setting Description Factory Default Overwrite the oldest event log

Overwrite the oldest event log. Overwrite the oldest event log

Stop recording event log

Disable Port Mirror for this port.

Click Apply to finish.

To view all of the event formation, check the lower part of the event log page.

Page 175: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-160

Threshold Settings

To configure the event log threshold, click the Threshold Setting tab on the Event Log Page. The event log threshold can be set up to send an early warning when the event log entries have reached the percentage of the threshold. The maximum recorded event log entries is 10,000.

Configure the following settings.

Capacity Warning

Setting Description Factory Default Enabled Enable capacity warning event log. Disabled

Disabled Disable capacity warning event log.

Page 176: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-161

Warning Threshold (%)

Setting Description Factory Default 50 to 100 Set the warning threshold as a percentage. 80

Maintenance and Tool This section explains how to maintain Moxa’s switch and the tools that help users operate the switch. Click the icon on the upper right corner of the page.

Standard/Advanced Mode There are two configuration modes available for users: Standard Mode and Advanced Mode.

1. In Standard Mode, some of the features/parameters will be hidden to make it easier to perform configurations (this is the default setting).

2. In Advanced Mode, some advanced features/parameters will be available for users to adjust these settings.

To switch to Advanced Mode, click the change mode icon on the upper right corner of the page, and then select Change Mode.

Page 177: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-162

Click Change to change to Advanced Mode.

Advanced Mode offers more detailed system configurations for specific functions. Use the same process if you want to return to Standard Mode.

Disable Auto Save Auto Save allows users to save the settings to the start-up configurations; all parameters will be effective when applied immediately, even when the switch has restarted. When users select Disable Auto Save, all parameters will be temporarily stored in the running config (memory), and a disk icon will appear on the upper right corner of the page. Users need to save the running-configuration to the startup-configuration when changing any parameters or function after clicking Apply.

It is highly recommended that you always manually save all configurations by clicking Save Disk icon when Disable Auto Save is applied, or all information will have disappeared after the switch has restarted.

When Disable Auto Save is applied, only the configurations that are running will be saved; users can unplug the power or perform a warm start to recover the network before manually saving the configurations. When Auto Save is enabled, the start-up configurations will be saved in the switch.

To disable the Auto Save function, click Disable Auto Save in the menu.

Page 178: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-163

Click Disable.

Locator Users can trigger the device locator by clicking this icon. This will cause the LED indicators on the switch to flash for one minute. This helps users easily find the location of the switch in a field site.

Click Locate to finish.

Duration (sec.)

Setting Description Factory Default 30 to 300 Specify the length of time the indicators will remain flashing. 60

Page 179: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-164

Click Locate to activate the switch locator. The LED indicators are located on the upper left corner of the switch as can be seen in the figure below.

Reboot To reboot the device, select Reboot.

Click Restart to reboot the device.

Page 180: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-165

Reset to Default To reset the switch to the default status, select Reset to Default.

To return the switch to factory default settings, click Reset.

Log Out of the Switch To log out of the switch, select Log Out.

Page 181: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Web Interface Configuration

3-166

Click Log Out to log out of the switch.

Page 182: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

A A. Account Privileges List

This appendix describes the read/write access privileges for different accounts on Moxa’s Managed Ethernet Series switches.

The following topic is covered in this appendix:

Account Privileges List

Page 183: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Account Privileges List

A-2

Account Privileges List This appendix lists the privileges for different account roles.

Please note, R stands for Read and W stands for Write.

Function Account Privilege

System Admin Supervisor User Information Setting R/W R/W R

Firmware Upgrade Execute No Access No Access

Configuration Backup and Restore Execute Execute No Access

Event log backup Execute Execute Execute

User Account R/W No Access No Access

Password Policy R/W No Access No Access

IP Configuration R/W R/W R

DHCP Server R/W R/W R

Time Zone R/W R/W R

System Time R/W R/W R

Port

Port Setting R/W R/W R

Linkup Delay R/W R/W R

Link Aggregation (Port Channel) R/W R/W R

PoE R/W R/W R

VLAN IEEE 802.1Q R/W R/W R

GARP R/W R/W R

MAC Static Unicast R/W R/W R

MAC Address Table R/W R/W R

QoS Classification R/W R/W R

Ingress Rate Limit R/W R/W R

Scheduler R/W R/W R

Egress Shaper R/W R/W R

Multicast IGMP Snooping R/W R/W R

Static Multicast R/W R/W R

GMRP R/W R/W R

Layer 2 Redundancy Spanning Tree R/W R/W R

Turbo Ring v2 R/W R/W R

Turbo Chain R/W R/W R

Dual Homing R/W R/W R

Network Management SNMP R/W No Access No Access

SNMP Trap/Inform R/W No Access No Access

RMON1 (CLI only) R/W R/W R

Page 184: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Account Privileges List

A-3

System Admin Supervisor User

Security Management Interface R/W R/W R

Login Policy R/W R R

Trusted Access R/W R R

SSH & SSL Execute Execute No Access

IEEE802.1X R/W R/W R

Port Security R/W R/W R

Traffic Storm Control R/W R/W R

Authentication

RADIUS R/W No Access No Access

TACACS+ R/W No Access No Access

Login Authentication R/W No Access No Access

Diagnostics Event Notification R/W R/W R

Relay Output R/W R/W R

Email Notification R/W R R

Syslog R/W R R

Event Log R/W R/W R

LLDP R/W R/W R

Port Mirror R/W R/W R

Ping Execute Execute Execute

ARP Table R/W R/W R

Utilization R R R

Statistics R R R

Module information R R R

Maintenance and Tool Standard/Advance Mode Execute Execute Execute

Disable Auto Save R/W R/W R

Locator R/W R/W Execute

Reboot Execute Execute No Access

Reset to default R/W No Access No Access

Page 185: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

B B. Event Log Description

This appendix describes all of the information for the event logs. When an event occurs, it will be recorded in the event log files. Users can check the event log name and its event log description.

The following topic is covered in this appendix:

Event Log Description

Page 186: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Event Log Description

B-2

Event Log Description Event Log Name Event Log Description

Login success [Account:{{user_name}}] successfully logged in via {{interface}}.

Login fail [Account:{{user_name}}] log in failed via {{interface}}.

Login lockout [Account:{{user_name}}] locked due to {{failed_times}} failed login attempts.

Account setting changed Account settings of [Account:{{user_name}}] has been updated. Account settings of [Account:{{user_name}}] has been deleted. Account settings of [Account:{{user_name}}] has been created.

SSL Certification changed SSL certificate has been changed. SSL certificate has been regenerated.

Password changed The password of [Account:{{user_name}}] has been changed.

Cold start The system has performed a cold start.

Warm start The system has performed a warm start.

Configuration Changed Configurations {{modules}} have been changed by [Account:{{user_name}}].

Configuration Imported Configuration import has {{'successful'/'failed'}} by [Account:{{user_name}}].

Log capacity threshold The threshold of event log entries {{numbers}} has been reached.

PWR On Power {{index}} has turned on.

PWR Off Power {{index}} has turned off.

DI On Digital Input {{index}} has turned on.

DI Off Digital Input {{index}} has turned off.

Port link up Port {{number}} link up.

Port link down Port {{number}} link down.

Port Shutdown by Rate Limit Port {{number}} has excessive traffic and has shut down.

Port Recovery by Rate Limit Port {{number}} has been recovered by rate limit.

Port Shutdown by Port Security Port {{number}} has shut down due to violation of Port Security rule.

Topology Changed (Turbo Ring) Topology has been changed by Turbo Ring.

Topology Changed (RSTP) Topology has been changed by RSTP.

Topology Changed (Turbo Chain) Topology has been changed by Turbo Chain.

Topology Changed (Dual Homing) Topology has been changed by Dual Homing.

Coupling Changed Turbo Ring v2 Coupling path status has changed.

Master Changed Ring {{Index}} master has changed.

Master Mismatch Ring {{Index}} master setting does not match.

RSTP Topo. Changed Topology has been changed by RSTP.

RSTP Root Changed RSTP new root has been elected in topology.

RSTP Migration Port {{number}} changed to RSTP Port {{number}} changed to STP.

RSTP Invalid BPDU RSTP port {{number}} received an invalid BPDU (type: {{type}}, value:{{value}}).

RSTP new port role RSTP port {{number}} role changed from {{role}} to {{role}}.

Redundant port health check fail Redundant port {{number}} health check fail.

Dual Homing path changed Dual Homing path has switched.

Dot1x Auth Fail 802.1X authentication failed on port {{number}} with {{mac address}}.

LLDP Table Changed LLDP remote table changed.

RMON raising alarm {{user defined}}.

RMON falling alarm {{user defined}}.

PD power on Port {{number}} PD power on.

PD power off Port {{number}} PD power off.

Low input voltage The input voltage of the power supply has dropped below 46 VDC. Please adjust the voltage to between 46 and 57 VDC to fit the PoE voltage requirements.

Page 187: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS Event Log Description

B-3

Event Log Name Event Log Description

PD over current Current of port {{number}} has exceeded the safety limit. Please check the device status.

PD no response Port {{number}} device is not responding to the PD failure check. Please check the device status.

Over power budget limit The consumed power {{power_value}} of all the PDs have exceeded the maximum input power {{input_power_value}}.

Power detection failure 1. Port {{number}} device is {{Legacy PD}}. Please {{enable legacy PD detection}}. 2. Port {{number}} device is {{Unknown}}. Please {{select PoE output mode to Force}}.

Relay Override Message {{MGMT/PWR1/PWR2}} relay alarm is on due to {{Event Name}}.

SSH Key Generate SSH key has been regenerated.

Configuration Export Configuration export {{successful /failed}} by [Account:{{user_name}}].

FWR upgrade success Firmware Successfully Upgraded.

Module init fail Module {{module_number}} Initialized Failed.

Violation in Port Security Port {{number}} dropped packets due to violation of Port Security rule.

Relay Cut Off {relay_name} relay alarm has been cut off.

Module Insert Module {{Index}} Inserted.

Module Remove Module {{Index}} Removed.

Power Module Insert Power Module {{Index}} Inserted.

Power Module Remove Power Module {{Index}} Removed.

TACACS+ Auth. Success [Account:{{user_name}}] successfully logged in via {{interface}}.

TACACS+ Auth. Fail [Account:{{user_name}}] log in failed via {{interface}}.

RADIUS Auth. Success [Account:{{user_name}}] successfully logged in via {{interface}}.

RADIUS Auth. Fail [Account:{{user_name}}] log in failed via {{interface}}.

Page 188: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

C C. SNMP MIB File

This appendix contains the SNMP MIB file for the managed switch.

The following topics are covered in this appendix:

Standard MIB Installation Order

MIB Tree

Page 189: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS SNMP MIB File

C-2

Standard MIB Installation Order If you need to import the MIB one-by-one, please install the MIBs in the following order.

1. RFC1213-MIB.mib

2. SNMP-FRAMEWORK-MIB.mib

3. SNMPv2-SMI.mib

4. SNMPv2-TC.mib

5. SNMPv2-CONF.mib

6. SNMPv2-MIB.mib

7. IANAifType-MIB.mib

8. IEEE8023-LAG-MIB.mib

9. IF-MIB.mib

10. EtherLike-MIB.mib

11. IEEE8021-PAE-MIB.mib

12. BRIDGE-MIB.mib

13. P-BRIDGE-MIB.mib

14. RFC1271-MIB.mib

15. RMON-MIB.mib

16. TOKEN-RING-RMON-MIB.mib

17. RMON2-MIB.mib

18. Q-BRIDGE-MIB.mib

19. INET-ADDRESS-MIB.mib

20. IEEE8021-TC-MIB.mib

21. IEEE8021-SPANNING-TREE-MIB.mib

22. IANA-ADDRESS-FAMILY-NUMBERS-MIB.mib

23. LLDP-MIB.mib

24. LLDP-EXT-DOT1-MIB.mib

25. LLDP-EXT-DOT3-MIB.mib

Page 190: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS SNMP MIB File

C-3

MIB Tree Refer to the following content for the MIB Tree structure.

iso(1)

|-std(0)-iso8802(8802)-ieee802dot1(1)-ieee802dot1mibs(1)

|-ieee8021paeMIB(1): IEEE8021-PAE-MIB.mib

|-ieee8021SpanningTreeMib(3): IEEE8021-SPANNING-TREE-MIB.mib

|-org(3)

|-dod(6)-internet(1)

|-mgmt(2)-mib-2(1): SNMPv2-MIB.mib

|-system(1): RFC1213-MIB.mib

|-interface(2): RFC1213-MIB.mib

|-at(3): RFC1213-MIB.mib

|-snmp(11): RFC1213-MIB.mib

|-rmon(16): RMON-MIB.mib

|-dot1dBridge(17): BRIDGE-MIB.mib, P-BRIDGE-MIB.mib, Q-BRIDGE-MIB.mib

|-ifMIB(31): IF-MIB.mib

|-etherMIB(35): EtherLike-MIB.mib

|-private(4)-moxa(8691)

|-product(600): mxGeneralInfo.mib, mxProductInfo.mib,

|-general(602): mxGeneral.mib, mxDeviceIo.mib, mxDhcpSvr.mib, mxEmailC.mib,

mxEventLog.mib,

:mxGene.mib, mxLocator.mib, mxManagementIp.mib, mxPoee.mib,

mxPorte.mib,

: mxRelayC.mib, mxSnmp.mib, mxSwe.mib, mxSysLoginPolicySvr.mib,

: mxSyslogSvr.mib, mxSysPasswordPolicySvr.mib, mxSystemInfo.mib,

: mxSysTrustAccessSvr.mib, mxSysUtilSvr.mib, mxTimeSetting.mib,

: mxTimeZone.mib, mxTrapC.mib, mxUiServiceMgmt.mib

|-switching(603): mxSwitching.mib

|- portInterfacce : mxPort.mib, mxLa.mib

|- basicLayer2: mxLhc.mib, mxQos, mxVlan.mib

|- layer2Redundancy: mxRstp.mib, mxTrv2.mib, mxTurboChain.mib,

mxDualHoming.mib

|- layer2Security: mxStcl.mib, mxRlps.mib, mxPssp.mib, mxPsms.mib, mxDot1x.mib,

mxRadius.mib

|- layer2Diagnosic: mxLldp.mib, mxTcst.mib, mxPortMirror.mib, mxRmon.mib

|- layer3Diagnosic

|- layer2Multicast: mxIgmpSnp.mib

Page 191: Moxa's Managed Switch Next Generation OS User's Manual · In this appendix, users can check the event log name and its event log description. When any event occurs, this appendix

Managed Switch Next Generation OS SNMP MIB File

C-4

|- layer3Multicast

|-poe(608): mxPoe.mib

|-snmpV2(6)-snmpModules(3)

|-snmpFrameworkMIB(10): SNMP-FRAMEWORK.mib

|-ieee(111)-standards-association-numbers-series-standards(2)-lan-man-stds(802)-ieee802dot1(1)-

ieee802dot1mibs(1)-ieee8021SpanningTreeMib(3): IEEE8021-SPANNING-TREE-MIB.mib