INDUSTRY STANDARDS

MOTOR RANGE

TEWAC motors: B4V - B5V - B5VH - B4VH

ODP motors: Low voltage C3M - C4M - C5M - C3W - C4W - C5W

ODP motors: Medium Voltage C3MH - C4MH - C5MH - C4MH - C4WH - C5WH

TEWC motors: B4J - B5J -B4JH - B5JH

TEFC motors: A5M - B5M - B5MH

GENERATOR RANGE

TEWAC generators: MJHRM

TEWAC generators: MJRM

TEAAC generators: MJVM

ODP generators: MJHM

ODP generators: MXB-EM

ODP generators: MJBM

AVR SELECTION TABLE

INDEX

04

07

08

11

11

14

17

20

22

27

32

36

41

44

49

Page 4: Motor and Generator Series

4 marellimotori.com

First number Second number

2 Machine protected against solid objects greater than 12 mm 2 Dripping water shall have no harmful effect from the vertical up to an angle up to 15°

3 Machine protected against solid objects greater than 2,5 mm 3 Spraying water shall have no harmful effect from the vertical up to an angle up to 60°

4 Machine protected against solid objects greater than 1 mm 4 Splashing water from any direction shall have no harmful effect

5 Machine protected against cust 5 Jets of water from any direction shall have no harmful effect

6 Machine totally protected against tight dust 6 Jets of water from heavy seas from any direction shall have no harmful effect

Industry standards

IP Code - Degree of protection (IEC - 60034 - 5)

Typical circuit arrangements

0 Free circulation

4 Machine surface - cooled

6 Heat exchanger machine mounted (using the motor surrounding coolant)

7 Heat exchanger built in the machine (not using the motor surrounding coolant)

8 Heat exchanger machine mounted (not using the motor surrounding coolant)

Typical methods of circulation

0 Free circulation

1 Self circulation

6 Circulation with independent device

Typical fluids

A Air

W Water

Example of designation - IP 44

IP Code IP

4 First number (protection against dust)

4 Second number (protection against liquid)

Example of designation - IC 411

IC Code IC

4 Circuit arrangement

A Primary fluid

1 Method of circulation for primary fluid

A Secondary fluid

1 Method of circulation for secondary fluid

IC Code - Cooling (IEC - 60034 - 6)

Page 5: Motor and Generator Series

5

IEC - 60034 - 7

IM B3

Code II: N° of bearings: Feet:Flange:Details:Mounting arrangement:

IM 10012With feet--Mounting by feet (Feet down)

IM B34

Code II: N° of bearings: Feet:Flange:Details:

Mounting arrangement:

IM 21012With feetWith flangeEnd Shield spigot No access to backFlange at D - End

Mounting by feet (Feet down with additional mounting on D - End Side of flange)

IM B35

Code II: N° of bearings: Feet:Flange:Details:

Mounting arrangement:

IM 21012With feetWith flangeEnd Shield spigot No access to backFlange at D - End

Mounting by feet (Feet down with additional mounting on D - End Side of flange)

IM B20

Code II: N° of bearings: Feet:Flange:Details:Mounting arrangement:

IM 11012With raised feet--Mounting by feet (Feet down)

IM B2

Code II: N° of bearings: Feet:Flange:Details:Mounting arrangement:

IM 21051With feetWith flange--

Mounting

Page 6: Motor and Generator Series

6 marellimotori.com

IEC - 60034 - 7

IM V10

Code II: N° of bearings: Feet:Flange:Details:Mounting arrangement:

IM 14112-With flangeSpecial flange on D - End.Mounted on D -End Side of flange, D - End down

B5

Code II: N° of bearings: Feet:Flange:Details:Mounting arrangement:

IM 30012-With flangeEndshield flange at D - End with access to backMounted on D -End Side of flange

V1

Code II: N° of bearings: Feet:Flange:Details:Mounting arrangement:

IM 30112-With flangeEndshield flange at D - End with access to backMounted on D -End Side of flange D - End down

IM B16

Code II: N° of bearings: Feet:Flange:Details:Mounting arrangement:

IM 13011With raised feet-Horizontal shaft - One bearing-

Page 7: Motor and Generator Series

7

ODPC_M C_MH C_W C_WHup to 10.000 kW

TEFCA5M B5M B5MHup to 1.900 kW

TEFCA5M B5M B5MHup to 1.900 kW

TEFCA5M B5M B5MHup to 1.900 kW

TEWACB4V B4VHup to 10.000 kW

TEWACB4V B4VHup to 10.000 kW

TEWCB4J - B4JH B5J - B5JHup to 4.000 kW

TEWCB4J - B4JH B5J - B5JHup to 4.000 kW

TEWCB4J - B4JH - B5J - B5JHup to 4.000 kW

Motor range

PROPULSION

DREDGE PUMPS

PTO - PTISYSTEM

AUXILIARIES

THRUSTERS

FI - FISYSTEM

WINCH

Key

ODP Open Drip Proof

TEWAC Totally Enclosed Water to Air Cooled

TEWC Totally Enclosed Water Cooled

TEFC Totally Enclosed Fan Cooled

TEWACB4V B4VHup to 10.000 kW

Our motors are suitable for the following applications:

TEWACB5V B5VHup to 4.000 kW

TEWACB5V B5VHup to 4.000 kW

TEWACB5V B5VHup to 4.000 kW

TEWACB5V B5VHup to 4.000 kW

Page 8: Motor and Generator Series

8 marellimotori.com

ModelLV B4V B5V

MV B4VH B4VH

Output Up to 10.000 kW

Voltages Up to 15.000 V

Frame 355 ÷ 1.000

Pole 4, 6, 8 and 10

Cooling IC 81W (IC 86W, IC 611, IC 616, IC 666 on request)

IP

B4V B4VH IP 44,54,55,56

B5V B5VH

IP 55 (IP 23, IP 44 with filters, IP 24W NEMA, IP56 on request)

Main applications

Propulsion, dredge pumps, winch, hybrid machine, PTO-PTI system

Other applications

Thrusters, Fi-Fi system, auxiliaries

Typical output 4 POLES 6 POLES 8 POLES 10 POLES

kW 50 Hz

B4V B4VH 5000 5600 5000 4000

B5V B5VH 3.340 3.330 2.900 1.200

kW 60 Hz

B4V B4VH 5600 6400 5700 4600

B5V B5VH 4.000 4.000 3.500 1.440

Certificates and testing

Marine Survey Certificate supplied with the machine.Shaft, housing (propulsion) and exchanger are certified by the Marine Classification So-ciety.

Certificate

Test and survey

TEWAC MOTORS: B4V - B5V - B4VH - B5VH

Page 9: Motor and Generator Series

9

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase the strength. Marelli Motori motors for continuous duty operation are designed to meet vibration levels as per IEC 60034-14.

Shaft designCylindrical shaft with key.

Mounted on side (right or left to be selected).Made of steels EN 10130.

Construction• mounted on top of the machine • double tube made of CuNi 90/10• copper fins housing• equipped with water leakage detector • certified by registers of shipping in compliance with Rules for Classification of Ship• coolant can be both fresh or sea water• suitable to be treated with corrosion inhibitors, PH regulators and anti freeze as ap-

propriate to site conditions.

Exchanger data• designed pressure 6 bar• test pressure 10 bar• max glycol: 30%• type of water: fresh water or marine (salt) water• flanges: PN6 – PN10 – Special (ANSI).

B4V B4VH Made of grey cast-iron (EN 1561 – GJL 200) up to 500 frame size motors. Made of hot-rolled structural steel (EN 10025 – S235 JR) from size 560 and above.

B5V B5VH Made of hot-rolled structural steel (EN 10025 – S235 JR).

Housing

Shield

Shaft

Internal fan

Heat Exchanger

Main terminal box

Main components

Cooling system

Degree of protection

Mounting

Construction

IC 81W as per IEC 60034-6. Primary fluid (water) is flowing by external water system. Internal air is flowing by a fan mounted on the shaft of the generator at the driven side.

IP 55 as per IEC 60034-5. (Available up to IP 56)

IM B3 and V1 as per IEC 60034-7

TEWAC – Totally Enclosed Water to Air CooledEnclosure

General data

B4V B4VH Made in carbon steel (EN 10083 – 2 C40 – TN) up to 450 frame and hot-rolled structural steel from 500 frame (EN 10025 – S355 JR).

B5V B5VH Made in carbon steel (EN 10083 – 2 C40 – TN)

B4V B4VH Made of aluminum alloy up to 400 frame.Made of hot-rolled structural steel above (EN 10025 – S235 JR).

B5V B5VH Made of hot-rolled structural steel (EN 10025 – S235 JR).

Page 10: Motor and Generator Series

10 marellimotori.com

Bearing

Insulation system

Protective treatments

Optional features

General data

Antifriction bearings grease lubricated (ball or roller type) or oil lubricated sleeve bearing.

The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours.

Locating bearings are on the D end side and floating bearings on the ND end side.

Both bearings are fitted with a regreasing system.

The used grease is removed through a valve locked in the outer bearing cover. Sleeve bearings available as an option.

On request special bearings are designed where high radial and axial forces are applied. All configurations are designed to withstand the following marine inclination

Stator is treated with an unsaturated polyester amide resin which is polymerisation in oven.

Stator: F class insulated with a synthetic enamel.(H class insulation available on request)

Dedicated protective enamel is applied on the winding.

• Dual/multiple winding configuration• flanged shaft or special shaft end on both sides• increase protection degree up to IP 56• encoder• vibration sensors• special frame design to suite the application• special bearings (sleeve or angular contact bearings)• reinforced winding for VFD operation• insulated bearings design for VFD application• shaft earth brush for VFD application• other options available on request.

Technical data

Stator/Rotor core

Rotor

Laminated and enamel-insulated on both sides to minimise eddycurrent losses. The stator winding is made of flat copper or round copper wire depending on the machine size.The completely wound stator pack is thereby impregnated in an polyester VPI. The subsequent heat treatment hardens the resin.

Squirrel cage rotor type.Depending on machine size, the rotor construction is either a solid shaft or welded rib-bed shaft. The rotor winding can be either a pressure die cast aluminum or a copper bar construction.

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

Dedicated construction available for defferente values.

Page 11: Motor and Generator Series

11

Model

Low voltage C3M - C4M - C5MC3W - C4W - C5WMedium voltageC3MH - C4MH - C5MHC3MH - C4WH - C5WH

Output Up to 10.000 kW

Voltages Up to 15.000 kV

Frame 315 ÷ 1000

Poles 4, 6, 8, 10 and 12

Cooling IC 01 / IC 06

IP IP 23 / IP 44

Main applications

Thrusters, Fi-Fi

Other applications

Small Propulsion

Certificates and testing

Certificate Marine Survey Certificate supplied with the machine.Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society.

Test and survey

Typical output 4 POLES 6 POLES 8 POLES 10 POLES

kW (at 60 Hz) 7.000 10.000 9.000 7.500

ODP MOTORS: C_M - C_MH - C_W - C_WH

Page 12: Motor and Generator Series

12 marellimotori.com

Main components

Housing

Shield

Shaft

Internal fan

Main terminal box

Enclosure

Cooling system

Degree of protection

Mounting

Construction

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase the strength.Marelli Motori motors for continuous duty operation are designed to meet vibration levels per IEC 60034-14, ISO 10816-1 and BS 5000-3.

Made of grey cast-iron (EN 1561 – GJL 200) up to 500 frame size motors. Made of hot-rolled structural steel (EN 10025 – S235 JR) from size 560 and above.

General dataMade in carbon steel (EN 10083 – 2 C40 – TN) up to 450 frame and hot-rolled structural steel from 500 frame (EN 10025 – S355 JR).

Shaft designCylindrical shaft with key.

Mounted on top.Made of cold-rolled formable steels EN 10025 – S235JR.

Made of aluminum alloy up to 400 frame.Made of hot-rolled structural steel above (EN 10025 – S235 JR).

ODP – Open Drip Proof Motors.

IC 01 as per IEC60034-6Free circulation.Internal air is flowing by a fan mounted on the shaft of the motor at the driven side.The cooling air is taken on the ND-end, the air outlet is on the D-end.On request for variable speed application an external ventilation unit can be supplied to get the IC 06 cooling type.

IP 23 as per IEC60034-5.The series can be supplied with air inlet filters to achieve the IP 44 rating. The motor series name will be C3W - C4W.

IM B3, V1 and V10 as per IEC 60034-7.

Page 13: Motor and Generator Series

13

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

Technical data

Laminated and enamel-insulated on both sides to minimise eddy-current losses. The stator winding is made of flat copper or round copper wire depending on the machine size. The completely wound stator pack with housing is thereby impregnated in an epoxy-resin VPI. The subsequent heat treatment hardens the resin.

Short circuit rotor type. Depending on machine size, the rotor construction is either a solid shaft or welded ribbed shaft.The rotor winding can be either a pressure die cast aluminum or a copper bar construc-tion.

General dataAntifriction bearings grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D end side and floating bearings on the ND end side.Both bearings are fitted with a regreasing system.The used grease is removed through a valve locked in the outer bearing cover. Sleeve bearings available as an option.On request special bearings are designed where high radial and axial forces are applied. All configurations are designed to withstand the following marine inclination.

Dedicated constructions available for different values

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerised in an oven.

Low voltage.Stator: F class insulated with a synthetic enamel.(H class insulation available on request)

Marine dedicated protective enamel is applied on the winding.

Stator/Rotor core

Rotor

Bearing

Insulation system

Impregnation system

Protective treatments

Optional features

• Dual/multiple winding configuration • flanged shaft or special shaft end on both sides• increase protection degree up to IP 56• encoder• vibration sensors• special frame design to suite the application• special bearings (sleeve or angular contact bearings)• reinforced winding for VFD operation• insulated bearings design for VFD application• shaft earth brush for VFD application• other options available on request.

Page 14: Motor and Generator Series

14 marellimotori.com

Model LV B4J - B5J

Model MV B4JH - B5JH

Output Up to 4.000 kW

Voltages B4J - B5J Up to 690 V B4JH - B5JH Up to 6.600 V

Frame 355 ÷ 630

Poles 4, 6, 8 and 10

Cooling IC 71W

IP IP 55 / IP 56

Main applications

Propulsion, thruster, dredge pump, hybrid machine, PTO-PTI system

Other applications

Fi - Fi system

Certificates and testing

Certificate Marine Survey Certificate supplied with the machine.Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society.Motors are ABS, RRR and DNV type approved.

Test and survey

Typical output 4 POLES 6 POLES 8 POLES

kW

(at 60 Hz)4.000 3.800 2.900

TEWC MOTORS: B4J - B5J - B4JH - B5JH

Page 15: Motor and Generator Series

15

Main components

Housing

Shield

Shaft

Internal fan

Heat Exchanger

Main terminal box

Enclosure

Cooling system

Degree of protection

Mounting

Construction

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase the strength.Marelli Motori motors for continuous duty operation are designed to meet vibration levels per IEC 60034-14, ISO 10816-1 and BS 5000-3.

Made of grey cast-iron (EN 1561 – GJL 200) up to 500 frame size motors.Made of hot-rolled structural steel (EN 10025 – S235 JR) from size 560 and above.

General dataMade in carbon steel (EN 10083 – 2 C40 – TN) up to 450 frame and hot-rolled structural steel from 500 frame (EN 10025 – S355 JR).

Shaft designCylindrical shaft with key

Mounted on top or side (with vertical mounting) and made in cast iron or cold rolled for-mable steels depending from size.

Made of aluminium alloy for 450 and 500 frame size.Made of hot-rolled structural steel from frame size 560 and above (EN 10025 – S235 JR).

General dataHeat exchanger is part of the housing and built on the machine. The material of the frame is carbon steel according to the standard EN 10025-S275JR. Equipped with water leakage detector as standard.

Exchanger dataWorking pressure < 6 barTest pressure 9 barMax glycol : 20%Coolant : fresh water only

TEWC – Totally Enclosed Water Cooled

IC 71W as per IEC 60034-6.7: Heat exchanger. The primary coolant is circulated in a closed circuit which is built as integral part of the machine.1: Self-circulation. The coolant is moved by a fan mechanically driven by the rotor.W: Coolant. Cooling water must be clean water.

IP 55 as per IEC 60034-5.

IM B3, V1 and V10 as per IEC 60034-7.

Page 16: Motor and Generator Series

16 marellimotori.com

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

Technical data

Laminated and enamel-insulated on both sides to minimise eddy-current losses. The stator winding is made of flat copper or round copper wire depending on the machine size. The completely wound stator pack with housing is thereby impregnated in an epoxy-resin VPI. The subsequent heat treatment hardens the resin.

Squirrel cage rotor type. Depending on machine size, the rotor construction is either a solid shaft or welded ribbed shaft.The rotor winding can be either a pressure die cast aluminum or a copper bar construction.

General dataAntifriction bearings grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D end side and floating bearings on the ND end side.Both bearings are fitted with a regreasing system.The used grease is removed through a valve locked in the outer bearing cover. Sleeve bearings available as an option.On request special bearings are designed where high radial and axial forces are applied. All configurations are designed to withstand the following marine inclination.

Dedicated constructions available for different values.

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerised in an oven.

Low voltageStator: F class insulated with a synthetic enamel.(H class insulation available on request)

Marine dedicated protective enamel is applied on the winding.

Stator/Rotor core

Rotor

Bearing

Insulation system

Impregnation system

Protective treatments

Optional features

• Dual/multiple winding configuration • flanged shaft or special shaft end on both sides• increase protection degree up to IP 56• encoder• vibration sensors• special frame design to suite the application• special bearings (sleeve or angular contact bearings)• reinforced winding for VFD operation• insulated bearings design for VFD application• shaft earth brush for VFD application• other options available on request.

Page 17: Motor and Generator Series

17

Model A5M - B5M - B5MH

Output Up to 1.900 kW

Voltages Up to 11.000 V

Frame 71 ÷ 500

Poles 2, 4, 6 and 8

Cooling IC 411 ( or IC 416)

IP IP 55/ IP 56/ IP 65

Main applications Auxiliaries, Fi-Fi system

Other applications Winch

Typical output 2 POLES 4 POLES 6 POLES 8 POLES

kW

(at 60 Hz)1.000 1.900 1.500 1.000

Certificates and testing

Certificate Marine Survey Certificate supplied with the machine.Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society.Motors are ABS, RRR and DNV type approved.

Test and survey

TEFC MOTORS: A5M - B5M - B5MH

Page 18: Motor and Generator Series

18 marellimotori.com

Main components

Motors from size 71 to 132 are made in cast iron. Motors from size 160 to 280 are made or in cast iron or in aluminium. Starting from frame 315 and up to 500 the frame is in cast iron only. (EN 1561-GJL – 200)

Made of grey cast-iron (EN 1561 – GJL 200) up to 500 frame size motors.

General data Made in carbon steel (EN 10083 – 2 C40 – TN) up to 500 frame

Shaft designCylindrical shaft with key.

Mounted on top and made of cold-rolled formable steels EN 10025 – S235JR or cast iron depending from size.

Made of aluminum alloy up to 500 frame.

TEFC MOTORS – Totally Enclosed Eater Cooled

IC 411 as per IEC 60034-6Totally enclosed standard motor, frame surface cooled with fan4: Frame surface cooled1: Self circulation of primary coolant1: Self circulation of secondary coolant

On request for variable speed application an external ventilation unit can be supplied to get the IC 416 cooling type.

IP 55 as per IEC 60034-5

IM B3 and V1 per IEC 60034-7

Housing

Shield

Shaft

Fan

Main terminal box

Enclosure

Cooling system

Degree of protection

Mounting

Construction

Page 19: Motor and Generator Series

19

Technical data

Laminated and enamel-insulated on both sides to minimise eddy-current losses. The stator winding is made of flat copper or round copper wire depending on the machine size. The completely wound stator pack with housing is thereby impregnated in an epoxy-resin VPI. The subsequent heat treatment hardens the resin.

Short circuit rotor type.Depending on machine size, the rotor construction is either asolid shaft or welded ribbed shaft.The rotor winding can be either a pressure die cast aluminum or a copper bar construc-tion.

General dataAntifriction bearings grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D end side and floating bearings on the ND end side.Both bearings are fitted with a regreasing system.The used grease is removed through a valve locked in the outer bearing cover. Sleeve bearings available as an option.On request special bearings are designed where high radial and axial forces are applied.

Dedicated constructions available for different values.

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerised in an oven.

Low voltageStator: F class insulated with a synthetic enamel.(H class insulation available on request)

Marine dedicated protective enamel is applied on the winding.

Stator/Rotor core

Rotor

Bearing

Insulation system

Impregnation system

Protective treatments

Optional features

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

• Dual/multiple winding configuration • flanged shaft or special shaft end on both sides• increase protection degree up to IP 56• encoder• vibration sensors• special frame design to suite the application• special bearings (sleeve or angular contact bearings)• reinforced winding for VFD operation• insulated bearings design for VFD application• shaft earth brush for VFD application • other options available on request.

Page 20: Motor and Generator Series

20 marellimotori.com

Page 21: Motor and Generator Series

21

TEWACMJHRMup to 11.000 kVA

TEWACMJHRMup to 11.000 kVA

TEWACMJRMup to 6.500 kVA

TEWACMJRMup to 6.500 kVA

ODPMJHMup to 12.500 kVA

ODPMJHMup to 12.500 kVA

ODPMXB-EM / MJBMup to 6.500 kVA

ODPMXB-EM / MJBMup to 6.500 kVA

Generator range

Key

TEFC Totally Enclosed Fan Cooled

TEAAC Totally Enclosed Air to Air Cooled

ODP Open Drip Proof

TEWAC Totally Enclosed Water to Air Cooled

TEWC Totally Enclosed Water Cooled

TEAACMJVMup to 5.600 kVA

EMERGENCY

PROPULSIONGENERATORS

SHAFTGENERATORS

AUXILIARYGENERATORS

HYBRID MACHINES

OFFSHORE

VARIABLESPEED

GENERATORS

ODPMXB-EM / MJBMup to 6.500 kVA

TEAACMJVMup to 5.600 kVA

Our generators are suitable for the following applications:

Page 22: Motor and Generator Series

22 marellimotori.com

Model MJHRM

Output Up to 11.000 kVA

Voltages Up to 15.000 V

Frame 400 ÷ 1.250

Poles 4, 6, 8, 10 and 12 (over contact MM)

Cooling IC 81W

IP IP 44. Available up to IP 56.

Main applications

Propulsion generator, shaft generator, hybrid machine, auxiliary generator, off-shore and variable speed gene-rator.

Certificate

Certificates and testing

Test and survey

Typical output 4 POLES 6 POLES 8 POLES 10 POLES 12 POLES

kVA(at 60 Hz) 10.000 9.000 11.000 11.000 10.000

Generators are designed in compliance with: IEC 60034 - 1BS 4999 - 5000VDE 0530NF 51 - 100NF 51 - 111OVE M - 10NEMA MG 1.32Generators conform to EU rules.UL/CSA certifications available on request.

Marine Survey Certificate supplied with the machine.Marelli Motori has the ABS design assessment.Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society.

Applicable standards

TEWAC GENERATORS: MJHRM

Page 23: Motor and Generator Series

23

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase the strength.Marelli Motori generators for continuous duty operation are designed to meet vibration levels per IEC 60034-14, ISO 10816-1 and BS 5000-3.

TEWAC - Totally Enclosed Water to Air Cooled.

Made of spheroidal graphite cast-iron (EN 1563) or grey cast-iron (EN 1561) up to 630 frame size.Made of structural steel (EN 10025 – S235 JR) above.

General dataMade in carbon steel and obtained by lamination (EN 10083–2 C40–TN). Shaft is obtained by forging from 290 mm diameter and above. The shaft is tested at the manufacturer in order to check it is defect-free.

Mounted on side (right or left will be selected). Made of formable steels EN 10130.

Made of aluminum alloy (EN 1706) or structural steel (EN 10025 – S235 JR) depending upon application requirements.

Shaft designDouble bearing generator: cylindrical shaft with key.

Housing

Enclosure

Shield

Cooling system

Shaft

Fan

Main terminal box

Main components

Degree of protection

Mounting

Construction

ConstructionMounted on top of alternator. Double tube made of CuNi 90/10.Copper fins housing.Equipped with water leakage detector.

Exchanger data• Designed pressure 6 bar• test pressure 10 bar • power: up to 200 kW • water flow: up to 18 m3/h • max glycol: 30%• type of water: fresh water or marine (salt) water• flanges: PN6 – PN10 – Special (ANSI) Position can be adjusted to site conditions.

Heat Exchanger

IC 81W as per IE C60034-6. Primary fluid (water) is flowing by external water system. Internal air is flowing by a fan mounted on the shaft of the generator at the driven side.

IP 44 as per IEC 60034-5. (Available up to IP 56)

Horizontal - IM 1001 or IM 1101 as per IEC 60034-7

Page 24: Motor and Generator Series

24 marellimotori.com

Laminated and enamel-insulated on both sides to minimise eddy-current losses.

Salient pole type.Made by copper flat wire.H class insulated with enamel coating.Winding retaining by pass-through bars of high quality steel.Rotating rectifier: Graetz diode bridge with 6 diodes.Rotors are dynamically balanced with a half key applied to the shaft extension in accor-dance with IEC 60034-14 to vibration grade normal A. Special vibration level construction is available.

General dataSingle or double antifriction bearing grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D-End side and floating bearings on the N-End side.

Bearing selection Antifriction bearings up to 560 frame size included. Sleeve bearings from 630 frame size included (available for smaller frame sizes)Antifriction bearings can be mounted on 630/710 frame size according to site working conditions.

Regreasing system (for antifriction bearing)Both bearings are fitted with grease nipple.

Bearing insulationND end bearing can be insulated to prevent any harmful circulating current from passing through the bearing surfaces. Insulated antifriction bearings in standard configuration:• 4, 6 poles: insulated N-End bearing from 630 frame size• 8 poles: insulated bearing from 400 frame size• 10 poles: insulated bearing from 500 frame size

All ND end sleeve bearings are insulated as standard. All configurations are designed to withstand the following marine inclination.

Stator: F class insulated with a synthetic enamel.Rotor: H class insulated with a synthetic enamel.

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerised in an oven.

Specific marine treatment.Epoxivinilic and polyacrylic. Total minimum thickness 120 micromillimeters.Epoxivinilic: Epoxy two component products, with vinyl change.Polyacrylic: Two components polyurethane product formulated with unmodified hydroxyl acrylic resin.

Technical data

Stator/Rotor core

Rotor

Bearing

Insulation system

Impregnation system

Protective treatments

Dedicated constructions available for different values.

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

Page 25: Motor and Generator Series

25

During continuous duty (S1), the following overloads are allowed: 10% for 1 hour 15% for 10 minutes30% for 4 minutes50% for 2 minutesThese overloads must be occasional and followed by one hour of running at normal load or less.

All generators are provided with an amply sized damper cage and are suitable for parallel operations with other generators, when equipped with the paralleling unit. A power fac-tor regulator (to work in parallel with the main) is available on request.

All generators comply with marine rules regarding transient performance. The voltage drop due to the application of 60% of nominal load is within 15%.

All generators equipped with an overboosting device ensure a three phase short circuit current (Icc) higher than three times the rated current (In): Icc > 300% In

All generators are equipped with Class B Group 1 radio interference filters as defined by EN 55011.

The no-load voltage wave form is sinusoidal with THD content less than 2%.

Vibration level is in accordance with ISO 10816. Measurement, evaluation and limits of vibration severity are in accordance with IEC 60034-14.

Overloads

Parallel operations

Transient ratings

Three phase short circuit current

Radio interference

THD (Total Harmonic Distortion)

Vibrations

Operating conditions

Page 26: Motor and Generator Series

26 marellimotori.com

Size Power (W)

400 - 560 400

630 - 710 600

800 - 900 800

1.000 1.000

1.120 1.200

1.250 1.400

Auxiliary device

Heaters installed at N-End side.

Space heaters

RTD - PT100 RTD devices in standard configuration:• 1 RTD on each phase of stator winding • 1 RTD on each bearing (≥630 frame size)Terminals in auxiliary terminal box.Other configurations available:

• DUPLEX type• RTD for inlet / outlet air • RTD for inlet / outlet water

• Reinforced construction for high linear vibrations• flanged shaft for direct coupling with engine flywheel (in case of single bearing solution)• neutral point terminals in separate terminal box • terminal box inside air duct (internal terminal box)• cooling system IC 86W with additional forced ventilation• cooler mounted on side• increase protection degree up to IP 54, IP 55 or IP 56• lifted feet to couple the generator with engine on existing baseframe• redundant rotating rectifier with 12 diodes• insulated bearing and earthing brush• AVR supplied loose• automatic power factor control (analog type)• digital AVR D-Vo for frame 400 – 800 (supplied loose) ( ≤6900V)• redundant AVR system• excitation/overboosting PMG mounted on generator( ≤6900V)• lubrication system for sleeve bearing• other options available on request.

Optional features

Page 27: Motor and Generator Series

27

Model MJRM

Output Up to 6.500 kVA

Voltages Up to 1.000 V

Frame 250 ÷ 900

Poles 4, 6, 8, 10 and 12 (over contact MM)

Cooling IC 81W/ IC 86W

IP IP 44. Available up to IP 56.

Main applications

Propulsion generator, shaft generator, hybrid machine, auxiliary generator, off-shore and variable speed generator.

Marine Survey Certificate supplied with the machine.Marelli Motori is DNV type approved and has the ABS design assessment. Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society.

Certificate

Test and survey

Typical output 4 POLES 6 POLES 8 POLES 10 POLES 12 POLES

kVA

(at 60 Hz)4.000 5.000 6.500 6.000 5.400

Certificates and testing

Generators are designed in compliance with: IEC 60034 - 1BS 4999 - 5000VDE 0530NF 51 - 100NF 51 - 111OVE M - 10NEMA MG 1.32All generators conform to EU rules.UL/CSA certifications available on request.

Applicable standards

TEWAC GENERATORS: MJRM

Page 28: Motor and Generator Series

28 marellimotori.com

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase the strength.Marelli Motori generators for continuous duty operation are designed to meet vibration levels per IEC 60034-14, ISO 10816-1 and BS 5000-3.

TEWAC - Totally Enclosed Water to Air Cooled

Made of spheroidal graphite cast-iron (EN 1563) or grey cast-iron (EN 1561) up to 630 frame size.Made of structural steel (EN 10025 – S235 JR) above.

Mounted on side (right or left will be selected). Made of formable steels EN 10130.

Made of aluminum alloy (EN 1706) or structural steel (EN 10025–S235 JR) depending on application requirements.

Housing

Enclosure

Shield

Cooling system

Shaft

Fan

Main terminal box

Main components

Degree of protection

Mounting

Construction

Heat Exchanger

Horizontal - IM 1001 or IM 1101 as per IEC 60034-7.

General dataMade in carbon steel and obtained by lamination (EN 10083–2 C40–N). Shaft is obtained by forging from 290 mm diameter and above.The shaft is tested at the manufacturer in order to check it is defect-free.

Shaft designDouble bearing generator: cylindrical shaft with key.

ConstructionMounted on top of alternator. Double tube made of CuNi 90/10.Copper fins housing.Equipped with water leakage detector.

Exchanger dataDesigned pressure 6 bar. Test pressure 10 bar Power: up to 200 kW Water flow: up to 18 m3/h Max glycol: 30%Type of water: fresh water or marine (salt) waterFlanges: PN6 – PN10 – Special (ANSI) Position can be adjusted to site conditions.

IC81W as per IEC 60034-6. Primary fluid (water) is flowing by external water system. Internal air is flowing by a fan mounted on the shaft of the generator at the driven side.

IP 44 as per IEC 60034-5. (Available up to IP 56)

Page 29: Motor and Generator Series

29

Laminated and enamel-insulated on both sides to minimise eddy-current losses.

Technical data

Stator/Rotor core

Rotor Salient pole type.Made by copper flat wire.H class insulated with enamel coating.Winding retaining by pass-through bars of high quality steel.Rotating rectifier: Graetz diode bridge with 6 diodes.Rotors are dynamically balanced with a half key applied to the shaft extension in accor-dance with IEC 60034-14 to vibration grade normal A. Special vibration level construction are available.

Stator: H class insulated with a synthetic enamel.Rotor: H class insulated with a synthetic enamel.

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerised in an oven.

Specific marine treatment.Epoxivinilic and polyacrylic. Total minimum thickness 120 micromillimeters.Epoxivinilic: Epoxy two component products, with vinyl change.Polyacrylic: Two components polyurethane product formulated with unmodified hydroxyl acrylic resin.

Bearing

Insulation system

Impregnation system

Protective treatments

General dataSingle or double antifriction bearing grease lubricated (ball or roller type) or oil lubrica-ted sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D-End side and floating bearings on the N-End side.Bearing selection Antifriction bearings up to 560 frame size included. Sleeve bearings from 630 frame size included (available for smaller frame sizes)Antifriction bearings can be mounted on 630/710 frame size according to site working conditions. Regreasing system (for antifriction bearing)Both bearings are fitted with a grease nipple.Bearing insulationND end bearing can be insulated to prevent any harmful circulating current from passing through the bearing surfaces. Insulated antifriction bearings in standard configuration:• 4, 6 poles: insulated N-End bearing from 630 frame size• 8 poles: insulated bearing from 400 frame size• 10 poles: insulated bearing from 500 frame sizeAll ND end sleeve bearings are insulated as standard. All configurations are designed to withstand the following marine inclination.

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

Dedicated constructions available for different values.

Page 30: Motor and Generator Series

30 marellimotori.com

During continuous duty (S1), the following overloads are allowed: 10% for 1 hour 15% for 10 minutes30% for 4 minutes50% for 2 minutesThese overloads must be occasional and followed by one hour of running at normal load or less.

All generators are provided with a amply sized damper cage and are suitable for parallel operations with other generators, when equipped with the paralleling unit. A power fac-tor regulator (to work in parallel with the main) is available on request.

All generators comply with marine rules regarding transient performance.The voltage drop due to the application of 60% of nominal load is within 15%.

All generators equipped with overboosting device to ensure a three phase short circuit current (Icc) higher than 3 times the rated current (In): Icc > 300% In

All generators are equipped with Class B Group 1 radio interference filters as defined by EN 55011.

The no-load voltage wave form is sinusoidal with THD content less than 2%.

Vibration level is in accordance with ISO 10816. Measurement, evaluation and limits of vibration severity are in accordance with IEC 60034-14.

Overloads

Parallel operations

Transient ratings

Three phase short circuit current

Radio interference

THD (Total Harmonic Distortion)

Vibrations

Operating conditions

Page 31: Motor and Generator Series

31

RTD devices in standard configuration:• 1 RTD on each phase of stator winding (≥630 frame size)Terminals in auxiliary terminal box.

Other configurations available:• DUPLEX type• RTD for inlet / outlet air • RTD for inlet / outlet water

Size Power (W)

250 125

315 - 355 200

400 - 560 400

630 - 710 600

800 - 900 800

Auxiliary devices

Heaters installed at N-End side. Heaters are standards on all frame size.Space heaters

RTD - PT100

Optional features

• Reinforced construction for high linear vibrations• flanged shaft for direct coupling with engine flywheel (in case of single bearing solution)• neutral point terminals in separate terminal box • terminal box inside air duct (internal terminal box)• cooling system IC 86W with additional forced ventilation• cooler mounted on side• increase protection degree up to IP 54, IP 55 or IP 56• lifted feet to couple the generator with engine on existing baseframe• redundant rotating rectifier with 12 diodes• insulated bearing and earthing brush• AVR supplied loose• automatic power factor control (analog type)• digital D-Vo for frame 250 – 710 (supplied loose)• redundant AVR system• excitation/overboosting PMG mounted on generator• lubrication system for sleeve bearing• other options available on request.

Page 32: Motor and Generator Series

32 marellimotori.com

Model MJVM

Output Up to 5.500 kVA

Voltages Up to 1.000 V

Frame 250 ÷ 900

Poles 4, 6, 8, 10 and 12(over contact MM)

Cooling IC 611

IP IP 44. Available up to IP 56

Main applications

Off-shore and emergency

Marine Survey Certificate supplied with the machine.Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society.

Certificate

Test and survey

Typical output 4 POLES 6 POLES 8 POLES 10 POLES 12 POLES

kVA

(at 60 Hz)3.500 4.300 5.600 5.600 4.600

Certificates and testing

Generators are designed in compliance with: IEC 60034 - 1BS 4999 - 5000VDE 0530NF 51 - 100NF 51 - 111OVE M - 10NEMA MG 1.32All generators conform to EU rules.UL/CSA certifications available on request.

Applicable standards

TEAAC GENERATORS: MJVM

Page 33: Motor and Generator Series

33

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase strength.Marelli Generators for continuous duty operation are designed to meet vibration levels per IEC 60034-14, ISO 10816-1 and BS 5000-3.

TEAAC – Totally Enclosed Air to Air Cooled

Made of spheroidal graphite cast-iron (EN 1563) or grey cast-iron (EN 1561) up to 630 frame size.Made of structural steel (EN 10025 – S235 JR) above.

IC 611 as per IEC 60034-6. Primary fluid (air) driven by a second fan (internal fan) mounted on shaft at N-End side. Internal air is flowing by a fan mounted on the shaft of the gene-rator at the driven side.

Mounted on side (right or left will be selected). Made of formable steels EN 10130.

Made of aluminum alloy (EN 1706) or structural steel (EN 10025 – S235 JR) depending on application requirments.

Made of structural steel (EN 10025 - 5235 JR)

ConstructionMounted on top of alternator. Tube made of P - AIMgSi UNI 3569Housing: EN 10025 - 5235JR

IP 44 as per IEC 60034-5

Horizontal - IM 1001 or IM 1101 as per IEC 60034-7

Housing

Enclosure

Shield

Cooling system

Shaft

Fan

Internal fan

Main terminal box

Heat Exchanger

Main components

Degree of protection

Mounting

Construction

General dataMade in carbon steel and obtained by lamination (EN 10083 – 2 C40 – TN). Shaft is obtai-ned by forging from 290 mm diameter and above. The shaft is tested by the manufacturer to ensure it is defect-free.

Shaft designDouble bearing generator: cylindrical shaft with key.

Laminated and enamel-insulated on both sides to minimise eddy-current losses.

Technical data

Stator/Rotor core

Page 34: Motor and Generator Series

34 marellimotori.com

General dataSingle or double antifriction bearing grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard ho-rizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D end side and floating bearings on the ND end side. Bearing selection Antifriction bearings up to 560 frame size included. Sleeve bearings from 630 frame size included (available for smaller frame sizes).Antifriction bearings can be mounted on 630/710 frame size according to site working conditions.

Regreasing system (for antifriction bearing)Both bearings are fitted with grease nipple.

Bearing insulationND end bearing can be insulated to prevent any harmful circulating current from passing through the bearing surfaces. Insulated antifriction bearings in standard configuration:• 4, 6 poles: insulated ND-end bearing from 630 frame size• 8 poles: insulated bearing from 400 frame size• 10 poles: insulated bearing from 500 frame size

All ND end sleeve bearings are insulated as standard. All configurations are designed to withstand the following marine inclination.

Stator: H class insulated with a synthetic enamelRotor: H class insulated with a synthetic enamel

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerised in an oven.

Specific marine treatment.Epoxivinilic and polyacrylic. Total minimum thickness 120 micromillimeters.Epoxivinilic: Epoxy two component products, with vinyl changePolyacrylic: Two components polyurethane product formulated with unmodified hydroxyl acrylic resin.

Bearing

Insulation system

Impregnation system

Protective treatments

Dedicated constructions available for different values.

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

During continuous duty (S1), the following overloads are allowed: 10% for 1 hour 15% for 10 minutes30% for 4 minutes50% for 2 minutesThese overloads must be occasional and followed by one hour of running at normal load or less.

Overloads

Operating conditions

Rotor Salient pole type.Made by copper flat wire.H class insulated with enamel coating.Winding retaining by pass-through bars of high quality steel.Rotating rectifier: Graetz diode bridge with 6 diodes.Rotors are dynamically balanced with a half key applied to the shaft extension in accor-dance with IEC 60034-14 to vibration grade normal A. Special vibration level construction are available.

Page 35: Motor and Generator Series

35

All generators equipped with overboosting device ensure a three phase short circuit cur-rent (Icc) higher than three times the rated current (In): Icc > 300% In.

All generators are equipped with Class B Group 1 radio interference filters as defined by EN 55011.

The no-load voltage wave form is sinusoidal with THD content less than 2%.

Vibration level is in accordance with ISO 10816. Measurement, evaluation and limits of vibration severity are in accordance with IEC 60034-14.

Three phase short circuit current

Radio interference

THD (Total Harmonic Distortion)

Vibrations

Auxiliary devicesHeaters installed at N-End side. Heaters are standard on all frame size.Space heaters

RTD - PT100 RTD devices in standard configuration:• 1 RTD on each phase of stator winding (≥630 frame size)Terminals in auxiliary terminal box.

Other configurations available:• DUPLEX type• RTD for inlet / outlet air • RTD into oil tank for sleeve bearing

Size Power (W)

250 125

315 - 355 200

400 - 560 400

630 - 710 600

800 - 900 800

Optional features

• Flanged shaft for direct coupling with engine flywheel (in case of single bearing solution)• neutral point terminals in separate terminal box• cooling system IC 616 with additional forced ventilation• increase protection degree up to IP 54, IP 55 or IP 56• lifted feet to couple the generator with engine on existing baseframe• redundant rotating rectifier with 12 diodes• insulated bearing and earthing brush• AVR supplied loose• automatic power factor control (analog type)• digital AVR D-Vo for frame 250 – 710 (supplied loose)• redundant AVR system• excitation/overboosting PMG mounted generator• other options available on request.

All generators are provided with a amply sized damper cage and are suitable for parallel operations with other generators, when equipped with the paralleling unit. A power fac-tor regulator (to work in parallel with the main) is available on request.

All generators comply with marine rules regarding transient performance. The voltage drop due to the application of 60% of nominal load is within 15%.

Parallel operations

Transient ratings

Page 36: Motor and Generator Series

36 marellimotori.com

Marine Survey Certificate supplied with the machine.Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society.

Model MJHM

Output Up to 12.500 kVA

Voltages Up to 15.000 V

Frame 400 ÷ 1.250

Poles 4, 6, 8, 10 and 12 (over contact MM)

Cooling IC 01

IP IP 23. Available up to IP 44 with filters

Main applications

Propulsion generator, shaft generator, hybrid machine, auxiliary generator, off-shore and variable speed gene-rator.

Certificate

Test and survey

Typical output 4 POLES 6 POLES 8 POLES 10 POLES 12 POLES

kVA

(at 60 Hz)10.000 9.000 11.000 11.000 10.000

Certificates and testing

Generators are designed in compliance with: IEC 60034 - 1BS 4999 - 5000VDE 0530NF 51 - 100NF 51 - 111OVE M - 10NEMA MG 1.32All generators conform to EU rules.UL/CSA certifications available on request.

Applicable standards

ODP GENERATORS: MJHM

Page 37: Motor and Generator Series

37

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase the strength.Marelli Generators for continuous duty operation are designed to meet vibration levels per IEC 60034-14, ISO 10816-1 and BS 5000-3.

ODP - Open Drip Proof

Made of spheroidal graphite cast-iron (EN 1563) or grey cast-iron (EN 1561) up to 630 frame size.Made of structural steel (EN 10025 – S235 JR) above.

Mounted on top.Made of formable steels EN 10130.

Made of aluminum alloy (EN 1706) or structural steel (EN 10025 – S235 JR) depending upon application requirements.

Housing

Enclosure

Shield

Cooling system

Shaft

Fan

Main terminal box

Main components

Degree of protection

Mounting

Construction

IC 01 as per IEC 60034-6

IP 23 as per IEC 60034-5

General dataMade in carbon steel and obtained by lamination (EN 10083–2 C40–TN). Shaft is obtained by forging from 290 mm diameter and above. The shaft is tested to ensure defect-free performance.

Shaft designDouble bearing generator: cylindrical shaft with key.

Horizontal - IM 1001 or IM 1101 as per IEC 60034-7

Technical dataStator/Rotor core

Rotor Salient pole type.Made by copper flat wire.H class insulated with enamel coating.Winding retaining by pass-through bars of high quality steel.Rotating rectifier: Graetz diode bridge with 6 diodes.Rotors are dynamically balanced with a half key applied to the shaft extension in accordan-ce with IEC 60034-14 to vibration grade normal A. Special vibration level constructions are available.

Laminated and enamel-insulated on both sides to minimise eddy-current losses.

Page 38: Motor and Generator Series

38 marellimotori.com

Stator: F class insulated with a synthetic enamelRotor: H class insulated with a synthetic enamel

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerized in an oven.

Specific marine treatment.Epoxivinilic and polyacrylic.Total minimum thickness 120 micromillimeters.Epoxivinilic: Epoxy two component products, with vinyl changePolyacrylic: Two components polyurethane product formulated with unmodified hydroxyl acrylic resin.

Insulation system

Impregnation system

Protective treatments

Dedicated constructions available for different values.

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

General dataSingle or double antifriction bearing grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D end side and floating bearings on the ND end side.

Bearing selection Antifriction bearings up to 560 frame size included. Sleeve bearings from 630 frame size included (available for smaller frame sizes)Antifriction bearings can be mounted on 630/710 frame size according to site working conditions.

Regreasing system (for antifriction bearing)Both bearings are fitted with grease nipple.

Bearing insulationND end bearing can be insulated to prevent any harmful circulating current from passing through the bearing surfaces. Insulated antifriction bearings in standard configuration:• 4, 6 poles: insulated ND end bearing from 630 frame size• 8 poles: insulated bearing from 400 frame size• 10 poles: insulated bearing from 500 frame size

All ND end sleeve bearings are insulated as standard. All configurations are designed to withstand the following marine inclination.

Bearing General dataSingle or double antifriction bearing grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D-End side and floating bearings on the N-End side.

Bearing selection Antifriction bearings up to 560 frame size included. Sleeve bearings from 630 frame size included (available for smaller frame sizes)Antifriction bearings can be mounted on 630/710 frame size according to site working conditions.

Regreasing system (for antifriction bearing)Both bearings are fitted with grease nipple.

Page 39: Motor and Generator Series

39

During continuous duty (S1), the following overloads are allowed: 10% for 1 hour 15% for 10 minutes30% for 4 minutes50% for 2 minutesThese overloads must be occasional and followed by 1 hour of running at normal load or less.

All generators are provided with an amply sized damper cage and are suitable for parallel operations with other generators, when equipped with the paralleling unit. A power fac-tor regulator (to work in parallel with the main) is available on request.

All generators comply with marine rules regarding transient performance. The voltage drop due to the application of 60% of nominal load is within 15%.

All generators equipped with an overboosting device ensure a three phase short circuit current (Icc) higher than 3 times the rated current (In): Icc > 300% In

All generators are equipped with Class B Group 1 radio interference filters as defined by EN 55011.

The no-load voltage wave form is sinusoidal with THD content less than 2%.

Vibration level is in accordance with ISO 10816. Measurement, evaluation and limits of vibration severity are in accordance with IEC 60034-14.

Overloads

Parallel operations

Transient ratings

Three phase short circuit current

Radio interference

THD (Total Harmonic Distortion)

Vibrations

Operating conditions

Page 40: Motor and Generator Series

40 marellimotori.com

Auxiliary devices

Heaters installed at N-End side.

Space heaters

RTD - PT100 RTD devices in standard configuration:• 1 RTD on each phase of stator winding • 1 RTD on each bearing (≥630 frame size)Terminals in auxiliary terminal box.

Other configurations available:• DUPLEX type• RTD for inlet / outlet air

Size Power (W)

400 - 560 400

630 - 710 600

800 - 900 800

1000 1000

1120 1200

1250 1400

• Reinforced construction for high linear vibrations• flanged shaft for direct coupling with engine flywheel (in case of single bearing solution)• neutral point terminals in separate terminal box • increase protection degree up to IP 44 with filters• lifted feet to couple the generator with engine on existing baseframe• redundant rotating rectifier with 12 diodes• insulated bearing and earthing brush• AVR supplied loose• automatic power factor control (analog type)• digital AVR D-Vo for frame 400 – 810 (supplied loose) (≤6900V)• redundant AVR system• excitation/overboosting PMG mounted on generator (≤6900V)• lubrication system for sleeve bearing• other options available on request.

Optional features

Page 41: Motor and Generator Series

41

Marine Survey Certificate supplied with the machine.Certificate

Certificates and testing

Generators are designed in compliance with: IEC EN 60034 - 1BS 4999 - 5000NEMA MG 1.32

Applicable standards

Model MXB-EM

Output Up to 375 kVA

Voltages Up to 480 V

Frame 160 ÷ 250

Poles 4

Cooling IC 01

IP IP 23. Available up to IP 44 from 180 to 250 frame size.

Other applications

Auxiliary generator, off-shore and emergency

Test and survey

ODP GENERATORS: MXB-EM

Page 42: Motor and Generator Series

42 marellimotori.com

ODP - Open Drip ProofEnclosure

Cooling system

Degree of protection

Mounting

Construction

IC 01 as per IEC 60034-6

IP 23 as per IEC 60034-5

Horizontal single bearing (160 frame size).Horizontal single bearing - double bearing available on request from 180 to 250 frame size.

Fabricated steel.

Made of Bakelite 7-pins (from 160 to 180 frame size); 9-pins (from 225 to 250 frame size).

Plastic up to MXB-EM 180 SC4 included - Aluminum alloy above.

Housing

Shaft

Fan

Terminal board

Main components

Carbon steel - hot rolled.

Fan

N-End Endshield.Aluminum alloy (from 160 to 225 frame size).Cast iron (250 frame size).

Shield

Laminated and enamel-insulated on both sides to minimise eddy-current losses.

Technical data

Stator/Rotor core

Rotor Salient pole type.Made by copper wire.H class insulated with enamel coating.Rotating rectifier: Graetz diode bridge with 6 diodes.Rotors are dynamically balanced.

Class H for stator and rotor.

Epoxy resin through high quality process.

CW 1081 on request.

Bearing

Insulation system

Impregnation system

Protective treatments

General dataSingle or double antifriction bearing grease lubricated (ball type).Bearing lifetime >=20'000 hours.

Page 43: Motor and Generator Series

43

During continuous duty (S1), the following overloads are allowed: 10% for 1 hour 15% for 10 minutes30% for 4 minutes50% for 2 minutesThese overloads must be occasional and followed by one hour of running at normal load or less.

All generators are provided with an amply sized damper cage and are suitable for parallel operations with other generators, when equipped with the paralleling unit (available on 180, 225 and 250 frame size).

Generators with auxiliary winding or PMG ensure a three phase short-circuit current (lcc) higher than 3 times the rated current (In): lcc > 3 In for 10 seconds.

All generators are equipped with Class B Group 1 radio interference filters as defined by EN 55011.

Tipically THD < 2% at no load / THF <2%.

Vibration level is in accordance with ISO 10816. Measurement, evaluation and limits of vibration severity are in accordance with IEC 60034-14.

Overloads

Parallel operations

Three phase short circuit current

Radio interference

THD (Total Harmonic Distortion) / THF

Vibrations

Operating conditions

Auxiliary devices

Heaters when installed:Space heaters

RTD - PT100 Configuration available:• N. 3 PT100 resistance temperature detectors in stator windings• N. 1 PT100 on N-End bearing• N. 1 PT100 duplex type on N-End bearing• N. 1 PT100 duplex type on D-End bearing (for double bearing configuration)• N.1 PT100 on D-End bearing (for double bearing configuration).

Size Power (W)

160 - 180 200

225 - 250 400

Optional features

• Increase protection degree up to IP 44• AVR supplied loose• automatic power factor control (analog type)• digital AVR D-Vo • redundant AVR system• excitation/overboosting PMG mounted on generator• other options available on request.

Page 44: Motor and Generator Series

44 marellimotori.com

Marine Survey Certificate supplied with the machine.Marelli Motori is DNV type approved and has the ABS design assessment. Shaft, housing (propulsion) and exchanger are certified by the Marine Classification Society. SOLAS compliance declaration.

Certificate

Test and survey

Typical output 4 POLES 6 POLES 8 POLES 10 POLES 12 POLES

kVA

(at 60 Hz)4.000 5.000 6.500 6.000 5.400

Certificates and testing

Generators are designed in compliance with: IEC 60034 - 1BS 4999 - 5000NEMA MG 1.32Generators conform to EU rulesUL/CSA certifications available on request.

Applicable standards

Model MJBM

Output Up to 6.500 kVA

Voltages Up to 1.000 V

Frame 315 ÷ 900

Poles 4, 6, 8, 10 and 12 (over contact MM)

Cooling IC 01

IP IP 23. Available up to IP 44 with filters.

Other applications

Propulsion generator, shaft generator, hybrid machine, auxiliary generator, off-shore, variable speed generator and emergency

ODP GENERATORS: MJBM

Page 45: Motor and Generator Series

45

Rigid frame, rugged welded steel fabrication (EN 10025 - S235 JR). Frame is provided with side ribs to increase the strength.Marelli Generators for continuous duty operation are designed to meet vibration levels per IEC 60034-14, ISO 10816-1 and BS 5000-3.

ODP - Open Drip Proof

Made of spheroidal graphite cast-iron (EN 1563) or grey cast-iron (EN 1561) up to 630 frame size.Made of structural steel (EN 10025 – S235 JR) above.

Mounted on top up to 630 frame size. Mounted on side from 710 frame size. Made of formable steels EN 10130.

Made of aluminum alloy (EN 1706) or structural steel (EN 10025–S235 JR) depending on application requirements.

Housing

Enclosure

Shield

Cooling system

Shaft

Fan

Main terminal box

Main components

Degree of protection

Mounting

Construction

IC 01 as per IEC 60034-6

IP 23 as per IEC 60034-5

Horizontal - IM 1001 or IM 1101 as per IEC 60034-7

General dataMade in carbon steel and obtained by lamination (EN 10083 – 2 C40 – TN). Shaft is obtained by forging from 290 mm diameter and above. The shaft is tested at the manufacturer in order to check it is defect-free.

Shaft designDouble bearing generator: cylindrical shaft with key.

Page 46: Motor and Generator Series

46 marellimotori.com

Laminated and enamel-insulated on both sides to minimise eddy-current losses.

Technical data

Stator/Rotor core

Rotor Salient pole type.Made by copper flat wire.H class insulated with enamel coating.Winding retaining by pass-through bars of high quality steel.Rotating rectifier: Graetz diode bridge with 6 diodes.Rotors are dynamically balanced with a half key applied to the shaft extension in accor-dance with IEC 60034-14 to vibration grade normal. A. Special vibration level construc-tion are available.

Stator: H class insulated with a synthetic enamel.Rotor: H class insulated with a synthetic enamel.

Stator and rotor are VPI treated with an unsaturated polyester amide resin which is polymerised in an oven.

Specific marine treatment.Epoxivinilic and polyacrylic. Total minimum thickness 120 micromillimeters.Epoxivinilic: Epoxy two component products, with vinyl change.Polyacrylic: Two components polyurethane product formulated with unmodified hydroxyl acrylic resin.

Bearing

Insulation system

Impregnation system

Protective treatments

General dataSingle or double antifriction bearing grease lubricated (ball or roller type) or oil lubricated sleeve bearing.The theoretical lifetime of bearings, L10h according to ISO 281/1 standard, of standard horizontal construction generators, without external forces (radial and / or axial) is in excess of 50.000 hours. On request, the lifetime of bearings, L10h can be in excess of 100.000 hours. Locating bearings are on the D-End side and floating bearings on the N-End side.Bearing selection Antifriction bearings up to 560 frame size included. Sleeve bearings from 630 frame size included (available for smaller frame sizes).Antifriction bearings can be mounted on 630/710 frame size according to site working conditions.

Regreasing system (for antifriction bearing)Both bearings are fitted with a grease nipple.

Bearing insulationND end bearing can be insulated to prevent any harmful circulating current from passing through the bearing surfaces. Insulated antifriction bearings in standard configuration:• 4, 6 poles: insulated N-End bearing from 630 frame size• 8 poles: insulated bearing from 400 frame size• 10 poles: insulated bearing from 500 frame size

All ND end sleeve bearings are insulated as standard. All configurations are designed to withstand the following marine inclination.

Dedicated constructions available for different values.

Static Dynamic

List 15° Rolling ±22.5°

Trim 5° Pitch ±7.5°

Page 47: Motor and Generator Series

47

During continuous duty (S1), the following overloads are allowed: 10% for 1 hour 15% for 10 minutes30% for 4 minutes50% for 2 minutesThese overloads must be occasional and followed by one hour of running at normal load or less.

All generators are provided with a amply sized damper cage and are suitable for parallel operations with other generators, when equipped with the paralleling unit. A power factor regulator (to work in parallel with the main) is available on request.

All generators comply with marine rules regarding transient performance. The voltage drop due to the application of 60% of nominal load is within 15%.

All generators equipped with overboosting device ensure a three phase short circuit cur-rent (Icc) higher than 3 times the rated current (In): Icc > 300% In

All generators are equipped with Class B Group 1 radio interference filters as defined by EN 55011.

The no-load voltage wave form is sinusoidal with THD content less than 2%.

Vibration level is in accordance with ISO 10816. Measurement, evaluation and limits of vibration severity are in accordance with IEC 60034-14.

Overloads

Parallel operations

Transient ratings

Three phase short circuit current

Radio interference

THD (Total Harmonic Distortion)

Vibrations

Operating conditions

Page 48: Motor and Generator Series

48 marellimotori.com

Auxiliary devices

Heaters installed at ND end side.Space heaters

RTD - PT100 RTD devices in standard configuration:• 1 RTD on each phase of stator winding (≥630 frame size)Terminals in auxiliary terminal box.

Other configurations available:• DUPLEX type• RTD for inlet / outlet air.

Size Power (W)

400 - 560 400

630 - 710 600

800 - 900 800

Optional features

• Reinforced construction for high linear vibrations• flanged shaft for direct coupling with engine flywheel (in case of single bearing solution)• neutral point terminals in separate terminal box• increase protection degree up to IP 44• lifted feet to couple the generator with engine on existing baseframe• redundant rotating rectifier with 12 diodes• insulated bearing and earthing brush• AVR supplied loose• automatic power factor control (analog type)• digital AVR D-Vo• redundant AVR system• excitation/overboosting PMG mounted on generator• lubrication system for sleeve bearing• other options available on request.

Page 49: Motor and Generator Series

49

AVR Selection table

AVR typeDigital

D-Vo Light D-Vo

Code 10024471 10024470

Generator voltage ≤6900V >6900V ≤6900V >6900V

Generator frame size

Standard 160 ÷ 800+ 400 ÷ 800+ - -

Optional - - 160 ÷ 800+ 400 ÷ 800+

AVR supplyStandard Mains, Auxiliary winding PMG Mains, Auxiliary winding PMG

Optional PMG - PMG -

Over-excitation device Auxiliary winding (1)

VARICOMP (2) PMG Auxiliary winding (1)

VARICOMP (2) PMG

Voltage sensing Three phase (3)

Voltage remote control Arrangement

Radio interference suppressor Arrangement for external filters

Parallel operation with the mains Internal

Parallel operation with similar generators Arrangement

Standard protections

Field over-current, Field over-voltage,

Generator over/under voltage, Generator over-current,

Loss of sensing

Limiters Under-frequency,Over/Under-excitation

Functions

PC interface, Soft start,

Auxiliary inputs, Contact inputs,

DMS

--

Modbus TCPFRT function

Certification DNV-GL-

DNV-GLUL

(1) Standard on all 4 pole L.V. 160 ÷ 450 generators.(2) Standard on the following generators: • 6+ pole 400 ÷ 450 frame ≤1000V• all 500+ frame generators• all 400 ÷ 450 frame ≤6900V.(3 ) Single-phase sensing is standard for all MJH generators, three-phase sensing is optional.

Page 50: Motor and Generator Series

Asia PacificMarelli Motori Asia Sdn BhdNo. 7, Jalan Tajuh Satu 27/29A, Section 27, 40400 Shah Alam, Selangor Darul Ehsan Malaysia (T) +60 3 5102 [email protected]

Central EuropeMarelli Motori Central Europe Gmbh Heilswannenweg 5031008 Elze - Germany(T) +49 5068 462 400(F) +49 5068 462 [email protected]

CONTACTS

Italy HQMarelli Motori S.r.l.Via Sabbionara 136071 Arzignano (VI) - Italy (T) +39 0444 479 711(F) +39 0444 479 [email protected]

USAMarelli USA, Inc.2200 Norcross Parkway, Suite 290 Norcross, GA 30071 - United States(T) +1 859 734 2588(F) +1 859 734 [email protected]

South AfricaMarelli Motori South Africa (Pty) Ltd Unit 2, corner Director & Megawatt Road Spartan Ext. 23Kempton Park 1619 GautengRepublic of South Africa(T) +27 11 392 1920(F) +27 11 392 [email protected]

SpainRepresentative Office08195 Sant CugatBarcelona - Spain(T) +34 664 464 [email protected]

marellimotori.com