Page 1: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Monitoring + Assurance

March 2020

Page 2: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

HeadEnd

Device

CO

FarEnd

Device

CPE

RemoteReflect

Coupler In/out

Demarcation Reflector

Two realization options:• Pluggable demarcation reflector (FC/SC)• Patchcord with integrated reflector (LC/PC)

3 WDM Coupler

Two realization options:• 1HU module w 16 integrated filters (LC/PC)• Ruggedized Y-cable (LC/PC)

2

Single Fiber Sheath

ALM Monitor Unit1

Two variants:AC and DC

ALM System Hardware2

Page 3: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

ALM Wavelength Overview

1300 1400 1500 1600 1700

Pow

er [m

W]

Wavelength [nm]

CWDM

Gre

y In

terf

ace

DWDM

C-B

and

DWDM

L-B

and

ALM

-M

onito

r

Permanent ALM Monitoring does not interfere with any other transport wavelengths

Physical Layer Monitoring3

Page 4: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

16ALM/PTP/AC

Parameter ValueShelf size 1HU, half size

Connector type LC/APC to ALM filter 16/1CSM+#1650

Measuring wavelength 1650 nm

Fault detection accuracy +/- 10 m

Power AC and -48VDC variants

Management connection 1x RJ45 (1x RS232 for debug)

Management system • Stand alone, HTML web interface• SNMPv1 for alarm notification

16ALM/PTP/-48VDC

ALM Monitoring Unit4

Выступающий
Заметки для презентации
Минимальное дистанция детектирования 10 метров
Page 5: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• HW is based on the ALM16, both AC and DC should be available at the same time

• Performance comparison with ALM16• Dynamic range is slightly lower (~2dB) because of higher insertion loss 1x64

switch• Scanning speed of ~4 minutes for all 64 ports (in an Access Network). Priority

ports can be defined for faster scanning speeds

R2.3 – 64-port ALM (ALM64)5

Выступающий
Заметки для презентации
Обычно время сканирования составляет 1-6 секунд на порт для 64ALM, поэтому при сканирование всех портов время (примерно) 4-7 минут.
Page 6: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

3G/4G USB dongle for remote DNC access6

• On some sites a DCN might not be available. Remote access can be realized to an ALM in that case by using a 3G/4G Dongle

• The following dongles are currently under test:• ZTE MF823• D-Link DWP-157• Huawei E3372 4G LTE

• Note: it is uncertain yet which of these dongles are going to be included in the release

• ADVA does not resell the dongles. Customers are to purchase the dongles directly

USB Dongle is connected to MGMT port

Page 7: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• 1HU shelf with 16 integrated WDM Couplers• Only one 16/1CSM/1HU+#1650 module

required per ALM Monitor Unit.• 16 LC/APC cables are required to connect

the ALM Monitoring Unit to the shelf

• Ruggedized Y-cable with an integrated WDM Coupler • Per ALM port a Y-cable needs to be used

(up to 16 cables per ALM monitor unit)

16/1CSM/1HU+#1650

J-Y/SM/1CS+#1650/LC/0310

Y-Cable

Coupler Shelf

ALM Coupler Options7

Выступающий
Заметки для презентации
Оптические сплитеры ответвляют 2% мощности на сенсор. Max 1.2 дБ ослабления оптической мощности
Page 8: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

A 32x WDM Coupler shelf will be developed in 1RU with LC/PC connectors. In essence this is the same as the 16x WDM Coupler shelf, but then at double the density.

ALM Connections Data in Data out

32x WDM Coupler (32/1CSM/1HU+#1650)8

Выступающий
Заметки для презентации
32/1CSM будет вносить до 1.2dB, отражатели DR/PTP/LC до 1.4dB. Общие потери не должны превышать - 3dB.
Page 9: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• 8-channel WDM Coupler to be mounted next to ALM16• Standard ALM16 mounting brackets can be used• Mountable in 19”, 21” and 23” racks• Ideal for use with non-ADVA DWDM Transmission systems where the

required port count is typically not very high

8x WDM Coupler9

Page 10: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• Single demarcation reflector packaged in a stub enclosure with 310 cm fibers and LC connectors

• A demarcation reflector needs to be used per ALM(up to 16 cables per ALM monitor unit)

• Industrial Temperature Component (-40°C … +85°C)

• Pluggable SC enclosure (the same enclosurecommonly used for attenuators)

• A demarcation reflector needs to be used per ALM(up to 16 cables per ALM monitor unit)

• Industrial Temperature Component (-40°C … +85°C)

J/SM/DR/PTP/LC/03109

DR/PTP/SC

Pluggable Reflector

Patchcord Reflector

ALM Demarcation Reflector Options10

Page 11: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Partname #Refl Conn.1 FormFact Insertion Loss (Av+2S)

Pass Through BW (nm)

Isolation Comments

J/1/LBL/DR/PTP/NC/0155 1 G.657.A2fibre

Cable 1.0 dB 1262-1618 nm 55 dB No longer in GPL, reflektor formidspan monitoring and lowpower

F7/16/DR/PTP/SC/1HU 16 SC/PC f 1U Chassis 1.1 dB 1262-1618 nm 55 dB 16 reflectors in chassis

F7/4/DR/PTP/SC/1HU 4 SC/PC f ½ 1U Chassis 1.1 dB 1262-1618 nm 55 dB 4 reflectors in chassis

J/2/SM/DR/PTP/SC/0092 2 SC m Box 1.3 dB 1262-1618 nm 55 dB 2 reflectors in a box with pigtails

J/SM/DR/PTP/LC/0310 1 LC m Cable 0.8 dB 1262-1618 nm 40 dB

J/SM/DR/PTP/LA/0075 1 LC/APC m Cable 0.8 dB 1262-1618 nm 40 dB was wrongly in pricelist as J/SM/DR/PTP/SA/0310 and J/SM/DR/PTP/LC/0310.

DR/PTP/SC 1 SC/PC m Plug 1.0 dB 1262-1618 nm 40 dB

DR/PTP/SC/GREY 1 SC m Plug 1.2 dB 1262-1581 nm 40 dB Not suitable for CWDM traffic with 1590-1610nm lambdas.

DR/PTP/SC/APC/GREY 1 SC/APC m Plug 1.2 dB 1262-1581 nm 40 dB Not suitable for CWDM traffic with 1590-1610nm lambdas.

DR/OSFMA/LA 1 LC/APC m Plug na none na Reflector reflects full bandwidth to be used on monitor port of coupler (typical with OSFMA card).

Overview Demarcation Reflectors (see user guide for all specs.)

11

Page 12: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

200km = not an optical specification but a result of the software implementation

Dynamic Range (SNR=1) 1 μs pulse -> 25 dB1650nm

20 μs pulse -> 32 dB1650nm

Max. pulse fingerprint 3 μsDynamic range not specifiedEstimated to be ~ 27 dB1650nm

200 km max (manual)

Overall Performance 2.1.2 (16ALM/#1650D)12

Выступающий
Заметки для презентации
Comment: very little (nothing ?) related to detection of bends specified or guaranteed in specifications. 200km not in specs -< comes from Sw based on using the SW …
Page 13: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

can be measured

Assume fiber break in last ‘10 dB’ distance

38 dB1650nm = fiber loss we can bridge

145 km max (automatic mode)

Power and distance can be monitored.

(System can try upto 160 km)

Performance Fingerprint/Fault Analysis13

Page 14: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• In CO propagating the total launch power limited to a fixed 14 dBm.• In COUNTER propagating launch power can be higher if the span is long

enough.• Please refer to dedicated slides on DWDM power limits for more details

ALM16

...

OSFM-AAU X

O SC

AU X

O SC

Refl.

Refl.

OSFM-AAU X

O SC

AU X

O SC

EDFAE

EDFAE

Co Propagating

Counter Propagating

LaunchPower

LaunchPower

Max

Lau

nch

Pow

er [d

Bm]

Max 145km

DWDM Power limitsFor Release R2.1.2

14

Page 15: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• What is it?New reflector in an LC/APC plug form factor

• Reason for introduction:Pluggable reflector that can directly be connected to the AUX port of the OSFMA and newer amplifiers with internal ALM couplers.

• Supported wavelengths:Reflects full c-band so can only be used in combination with coupler or for cable monitoring, can not be used as reflector with data passing trough it.

Note: Has a simplex fiber connector so you need two if you want to reflect both fibers of the duplex AUX port

New Reflector for OSFMADR/OSFMA/LA

15

Выступающий
Заметки для презентации
OSFMA -> reflectors -> yes
Page 16: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

HTML Web-ServerSNMP

WEB-GUIHTML interface

FSP NM or 3rd PartySNMP Server

Management Communication

• HTML web-interface for direct control over the ALM and review of network status

• Communication using SNMP commands (including SNMP Traps)

• RS232 interface (for CLI)

• RJ45 interface 10/100MB

• Shipped with default IP address

• Web browser management tool

• Login/password required

ALM ManagementControl Options for Monitor Unit

16

Page 17: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• Human readable email format• Initial email implementation of the ALM was XML-format only• Some customers want to receive human readable emails• Email type to be sent can be configured in the ALM GUI

• SMS capability• In addition some customers request SMS notification• In order to send an SMS an “email-to-SMS” gateway is needed• Many gateways exist (some for free, some for a low fee)

• https://martinfitzpatrick.name/list-of-email-to-sms-gateways/• https://www.textmagic.com/email-to-sms/

SMS Gateway

Human Readable Email Format / SMS capability17

Page 18: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

OTDR curve to BASELINE comparison

On-Demand TestingAutomated Testing

Automated/Polledfiber link loss testScan every 1 min

On-demand fiber link OTDR analysis test

IP-based web interface

Automatic fiber link OTDR

analysis testBASELINE fiber measurements

Total insertion-loss to BASELINE comparison

Alarm Generation:Comparison exceeds error thresholds

ALM Operation Modes18

Page 19: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Management ALM (Examples)19

Page 20: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• In R2.3 fiber faults are detected automatically in bi-directional operation using a central NTP clock for synchronization

• The ALMs take turns measuring co/counter propagating fibers

NTPTimeslot 1 (15min)

Timeslot 2 (15min)

Timeslot 115min

Timeslot 215min

Timeslot 115min

Timeslot 215min

• A cable cut will cut both transmission fibers and thus will regardless of the timeslot be detected

Time

Bi-directional Operation - Active20

Page 21: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Fiber-cutdetected

Connectivity Assurance

Waterdetected

Intrusiondetected

ADVA SmartNOC

Intrusiondetected

Waterdetected

Fiber-cutdetected

CustomerNotification

DispatchRepair Service

GIS-based Assurance Service Offering21

Page 22: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• AutoCAD Map 3D based environment

• Geo Manager Plugin installed for editing

• Wide range of import/export functions

• Available “as-a-service” as well

Administrator

• Web-browser GUI

• Runs on PCs, tablets and phones

• Access to all service-relevant functions

• No special installation required

Service Engineer

Fiber-Optic Network

ALM

ALM

ALM

ALM

Geo Manager Server

SNMP

WebHost

Geo Manager Structure22

Выступающий
Заметки для презентации
Волокна создаются в программе AutoCAD Maps 3D. А потом они сохраняются в GEO Manager server Client Manager это WEB интерфейс (Интернет эксплорер), который подключается к Geo Manager Server, поэтому ограничений в количестве подключений нет. Если заказчик хочет сам рисовать волокна, то ему только понадобиться дополнительно купить у сторонних поставщиков AutoCAD Maps 3D.
Page 23: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• Gaus-Krüger Formats• RD Data• KML/KMZ Files• Shape Format• WGS-84• Many others

Import functions are offered for a wide range of data formats

Import Functions

Geo Manager Server

Fiber Data

ImportFunctions

Geo Manager Plugin for AutoCAD23

Comprehensive Data Import functions

Page 24: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Here’s how GIS Mapping works24

© 2016 ADVA Optical Networking. All rights reserved. Confidential.

GIS integration status• OSPInsight (available)• ConnectMaster (available)• Cocon (R2.2)• Smallworld (evaluation stage)• ArcGIS (evaluation stage)• NetGeo (evaluation stage)

Scalable ADVA GIS (under development)• Conversion tools• User management

GIS: Geographical Information System

Page 25: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

• GIS integration with Cocon and NetGEO has been realized through a REST interface

• Please refer to the dedicated slidedeck on Cocon for more information

Connection verification Link verification Fault identification

GIS Integration: Cocon and NetGEO25

Page 26: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

OSPInsight orConnectMaster

• OSPInsight support is present since ALM release R1.4

• In R2.1.1 support of ConnectMaster is added. It should be noted that ConnectMaster verified the Email functionality of the ALM16, but still has to do some work to complete integration on their end.

GIS Integration

XML-formatted email

Geographics Information System (GIS)26

Page 27: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Fibernet-of-Things

Investment protection via passive fiber sensors

Page 28: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Overcoming WiFi limitations with Fibernet-of-Things• Long reach of 100km and beyond

• Energy efficient communication over fiber

• Frequency jammers have no impact on the system

• No electricity required at sensor locations

Fibernet-of-Things allows secure surveillance and investment protection of a fiber-optic network

Pictures by: Eolismedia

Water

Intrusion

Temperature/FireFuture:

Fibernet-of-Things28

Выступающий
Заметки для презентации
может каскадировать до 15 люков на одном порту ALM для мониторинга. Рекомендуется в одной линии до 10 сенсоров. Если подключать 10 сенсоров,  то бюджет по затуханию линии - 10дБ
Page 29: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Manhole product style29

Page 30: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Sensor in normal / off condition Sensor in activated / on condition

ALM

95/5Optical Coupler

PC Connector orOptical Reflector

Sensor

Generates a reflection peak

ALM

95/5Optical Coupler

PC Connector orOptical Reflector

Sensor

Sensor attenuates reflection peak

Passive Reflection Concept30

Page 31: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Step 1: run finger print. The passive sensors can be easily detected by looking at the reflection peaks

Location of a passive sensor

Configuration of Passive Monitors31

Page 32: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Step 2: select the reflection peaks from the sensors that are to be monitored

Select reflection peaksfrom sensors to be

monitored

Configuration of Passive Monitors32

Page 33: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Door is closed

Door is opened -> alarm raised

In case an enclosure is opened, the reflection peak dissapears and an alarm is raised

Configuration of Passive Monitors32

Page 34: Monitoring + Assurance ALM.pdf · • 8-channel WDM Coupler to be mounted next to ALM16 • Standard ALM16 mounting brackets can be used • Mountable in 19”, 21” and 23” racks

Спасибо

IMPORTANT NOTICEThe content of this presentation is strictly confidential. ADVA Optical Networking is the exclusive owner or licensee of the content, material, and information in this presentation. Any reproduction, publication or reprint, in whole or in part, is strictly prohibited.

The information in this presentation may not be accurate, complete or up to date, and is provided without warranties or representations of any kind, either express or implied. ADVA Optical Networking shall not be responsible for and disclaims any liability for any loss or damages, including without limitation, direct, indirect, incidental, consequential and special damages, alleged to have been caused by or in connection with using and/or relying on the information contained in this presentation.

Copyright © for the entire content of this presentation: ADVA Optical Networking.

[email protected]