Rail Mount In-Line AmplifierModel DV-05 DIN
DESCRIPTIONThese in-line amplifiers feature DIN-rail mount enclosures with
front accessible electrical connections and adjustments. Ampli-
fiers are available for strain-gage transducers.
FEATURES• DIN rail mount
• Unamplified transducer input
• Bridge-based transducer input
• 0 to ±5 V three-wire output with 11 Vdc to 28 Vdc power
• 3 Vdc or 5 Vdc excitation
• RFI, ESD protected
• CE approved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model DV-05 DIN
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic
Mounting 35 mm DIN
Certification CE approved
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 11 Vdc to 28 Vdc
Current draw 60 mA
Zero adjustment range, coarse
±60 %
Zero adjustment range, fine ±10 %
Span adjustment range Switch selectable 0.5 mV/V to 13.3 mV/V
Span adjustment range, fine
±20 %
Linearity ±0.01 %
Output ±5 Vdc
Output current 2 mA
Frequency response (-3 db) dc 7000 Hz with 350 ohm bridge
dc 2500 Hz with 5000 ohm bridge
Rise time (0 % to 90 %) 56 ms with 350 ohm bridge
145 ms with 5000 ohm bridge
Signal-to-noise ratio 66 db
dc power supply rejection ratio
Greater than 110 db
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -29 °C to 82 °C [-20 °F to 180 °F]
Temperature, storage -40 °C to 93 °C [-40 °F to 200 °F] MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer excitation 3 Vdc or 5 Vdc @ 30 mA (short circuit protection)
98,5 mm[3.87 in]
Mating connector
Customer suppliedChart recorderAlarm panelData acquisitionComputerPLC
Power supply
Sensor Model DV-05
OPTION CODES
2-pole filteroption
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
58e, 2-pole filter setting
1 Hz 100 Hz3 Hz 300 Hz5 Hz 500 Hz10 Hz 1000 Hz20 Hz 2500 Hz (350 ohm bridge)30 Hz 7000 Hz (5000 ohm bridge)50 Hz
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008813-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model DV-05 DIN Rail Mount In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rail Mount In-Line AmplifierModel DA-05 DIN
DESCRIPTIONThese in-line amplifiers feature DIN-rail mount enclosures with
front accessible electrical connections and adjustments. Ampli-
fiers are available for strain-gage transducers.
FEATURES• DIN rail mount
• Strain gage transducer input
• Bridge-based transducer input
• 4 mA to 20 mA three-wire output
• 13 Vdc to 28 Vdc power supply
• 3 Vdc or 5 Vdc excitation
• RFI, ESD protected
• CE approved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model DA-05 DIN
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic
Mounting 35 mm DIN
Certification CE approved
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 13.5 Vdc to 28 Vdc
Current draw 60 mA
Zero adjustment range, coarse
±60 %
Zero adjustment range, fine ±10 %
Span adjustment range Switch selectable 0.5 mV/V to 13.3 mV/V
Span adjustment range, fine
±20 %
Linearity ±0.01 %
Output 4 mA to 20 mA three-wire
Frequency response (-3 db) dc 6200 Hz with 350 ohm bridge
dc 2300 Hz with 5000 ohm bridge
Rise time (0 % to 90 %) 63 ms with 350 ohm bridge
160 ms with 5000 ohm bridge
Signal-to-noise ratio 70 db
dc power supply rejection ratio
90 db
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -29 °C to 82 °C [-20 °F to 180 °F]
Temperature, storage -40 °C to 93 °C [-40 °F to 200 °F] MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer excitation 3 Vdc or 5 Vdc @ 30 mA (short circuit protection)
OPTION CODES
2-pole filteroption
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
58e, 2-pole filter setting
1 Hz 100 Hz3 Hz 300 Hz5 Hz 500 Hz10 Hz 1000 Hz20 Hz 6200 Hz (350 ohm bridge)30 Hz 2300 Hz (5000 ohm bridge)50 Hz
98,5 mm[3.87 in]
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008809-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model DA-05 DIN Rail Mount In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rail Mount In-Line AmplifierModel DV-10 DIN
DESCRIPTIONThese in-line amplifiers feature DIN-rail mount enclosures with
front accessible electrical connections and adjustments. Ampli-
fiers are available for strain-gage transducers.
FEATURES• DIN rail mount
• Unamplified transducer input
• Bridge-based transducer input
• 0 to ±10 V three-wire output with 15 Vdc to 28 Vdc power
• 5.4 Vdc or 9 Vdc excitation @ 30 mA
• RFI, ESD protected
• CE approved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model DV-10 DIN
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic
Mounting 35 mm DIN
Certification CE approved
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 15 Vdc to 28 Vdc
Current draw 60 mA
Zero adjustment range, coarse
±30 %
Zero adjustment range, fine ±5 %
Span adjustment range Switch selectable 1.75 mV/V to 13.3 mV/V
Span adjustment range, fine
-8 to +20
Linearity ±0.01 %
Output ±10 Vdc (three-wire)
Output current 2 mA
Frequency response dc -5000 Hz
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -29 °C to 82 °C [-20 °F to 180 °F]
Temperature, storage -40 °C to 93 °C [-40 °F to 200 °F]MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer excitation 5.4 Vdc or 9 Vdc @ 30 mA (short circuit protection)
OPTION CODES
2-pole filteroption
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
58e, 2-pole filter setting
1 Hz 100 Hz3 Hz 300 Hz5 Hz 500 Hz10 Hz 1000 Hz20 Hz 2500 Hz (350 ohm bridge)30 Hz 7000 Hz (5000 ohm bridge)50 Hz
98,5 mm[3.87 in]
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008814-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model DV-10 DIN Rail Mount In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rail Mount In-Line AmplifierModel DLD-VH DIN
DESCRIPTIONThese in-line amplifiers feature DIN-rail mount enclosures with
front accessible electrical connections and adjustments. Ampli-
fiers are available for ac-type displacement transducers with
outputs in both Vdc or mA.
FEATURES• DIN rail mount
• ac displacement transducer input
• 0 to ±5 Vdc or 0 to ±10 Vdc field selectable output with
18 Vdc to 36 Vdc power
• 3 V RMS @ 5 kHz
• RFI, ESD protected
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model DLD-VH DIN
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic
Mounting 35 mm DIN
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 18 Vdc to 36 Vdc
Power supply isolation 500 V
Current draw 100 mA
Zero adjustment range, coarse
±100 %
Zero adjustment range, fine ±20 %
Span adjustment range Switch selectable 0.1 VRMS to 15 VRMS input range
Span adjustment range, fine
±10 %
Linearity ±0.05 %
Output 0 ±5 Vdc or 0 ±10 Vdc (field selectable)
Frequency response (-3 db) 300 Hz
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -29 °C to 60 °C [-20 °F to 140 °F]
Temperature, storage -40 °C to 93 °C [-40 °F to 200 °F]
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type ac displacement transducers
Transducer excitation 3 V RMS @ 5 kHz
98,5 mm[3.87 in]
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008811-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model DLD-VH DIN Rail Mount In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Rail Mount In-Line AmplifierModel DLD-CH DIN
FEATURES• DIN rail mount
• ac displacement transducer input
• 4 mA to 20 mA output field selectable output with
18 Vdc to 36 Vdc power
• 3 V RMS @ 5 kHz
• RFI, ESD protected
DESCRIPTIONThese in-line amplifiers feature DIN-rail mount enclosures with
front accessible electrical connections and adjustments. Ampli-
fiers are available for ac-type displacement transducers with
outputs in both Vdc or mA.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model DLD-CH DIN
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic
Mounting 35 mm DIN
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 18 Vdc to 36 Vdc
Power supply isolation 500 V
Current draw 90 mA
Zero adjustment range, coarse
±100 %
Zero adjustment range, fine ±20 %
Span adjustment range Switch selectable 0.1 VRMS to 15 VRMS input range
Span adjustment range, fine
±10 %
Linearity ±0.05 %
Output 4 mA to 20 mA
Frequency response (-3 db) 300 Hz
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -29 °C to 60 °C [-20 °F to 140 °F]
Temperature, storage -40 °C to 93 °C [-40 °F to 200 °F]
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type ac displacement transducers
Transducer excitation 3 V RMS @ 5 kHz
98,5 mm[3.87 in]
Model DLD-CH
Customer suppliedChart RecorderAlarm PanelData AcquisitionComputerPLC
Power supply
AC LVDT
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008810-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model DLD-CH DIN Rail Mount In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Universal Bi-Polar In-Line AmplifierModel UBP
FEATURES• For replacement only, not to be used in new design
• Strain gage sensor amplifier
• ±5 Vdc output
• ±15 Vdc supply voltage
• NEMA 4 housing
• Selectable excitation voltages: 3 V, 5 V, or 10 V @ 70 mA
• Increases signal-to-noise ratio in noisy environments
• Effects of voltage drops in excitation sources are eliminated
• Signals may be sent to the data systems from low impe-
dence sources
DESCRIPTIONThe Model UBP bi-polar amplifier supplies a highly regulated
bridge excitation voltage for the transducer and converts the
millivolt signal of the transducer to a ±5 Vdc signal. The Univer-
sal In-line features two selectable excitation voltages, program-
mable gain settings, a wide adjustment range on the zero, and a
buffered solid-state shunt cal relay for quick calibration.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model UBP
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic or painted Aluminum
Mounting Use #6 or #8 screws
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -15 °C to 71 °C [5 °F to 160 °F]
Sealing IP66 or NEMA 4
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer excitation 3 Vdc, 5 Vdc or 10 Vdc @ 70 mA
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage ±15 Vdc
Current draw 70 mA
Frequency response (-3 db) dc to 5000 Hz
Zero adjustment range, coarse
±50 %
Zero adjustment range, fine ±15 %
Span adjustment range 0.5 mV/V to 10 mV/V, ±25 % fine
Linearity 0.01 % of full scale
Shunt calibration Solid state relay on board
Signal output ±5 Vdc
Output current 1 mA max.
Signal-to-noise ratio 65 db
dc power supply rejection ratio
> 110 db
Signal-to-noise ratio 65 db
dc power supply rejection ratio
> 110 db
OPTION CODES
2-pole active filter
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Filter setting 1 Hz 50 Hz3 Hz 100 Hz5 Hz 300 Hz10 Hz 500 Hz20 Hz 1000 Hz30 Hz
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008832-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model UBP Universal Bi-Polar In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Bridge Based Sensor In-Line AmplifierModel UV
DESCRIPTIONThe Model UV amplifier supplies a highly regulated bridge exci-
tation voltage for the transducer and converts the millivolt signal
of the transducer to a ±10 Vdc signal. The Universal In-line
features two selectable exciation voltages, programmable gain
settings, a wide adjustment range on the zero, and a buffered
solid-state shunt cal relay for quick calibration.
FEATURES• Strain gage sensor amplifier
• ±5 Vdc three-wire output
• 3 V or 5 V excitation voltages @ 70 mA
• 11 Vdc to 28 Vdc supply voltage
• NEMA 4 housing
• Increases signal-to-noise ratio in noisy environments
• Effects of voltage drops in excitation sources are eliminated
• Signals may be sent to the data systems from low impe-
dence sources
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model UV
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic or painted Aluminum
Mounting Use #6 or #8 screws
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -15 °C to 71 °C [5 °F to 160 °F]
Sealing IP66 or NEMA 4
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer excitation 3 Vdc or 5 Vdc @ 70 mA
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 11 Vdc to 28 Vdc
Current draw 50 mA
Frequency response (-3 dB) dc: 7000 Hz with 350 ohm bridge
dc: 5000 Hz with 5000 ohm bridge
Rise time (0 % to 90 %) 54 ms with 350 ohm bridge
78 ms with 5000 ohm bridge
Zero adjustment range, coarse
±50 %
Zero adjustment range, fine ±15 %
Span adjustment range 0.75 mV/V to 13.3 mV/V ±25 % fine adjustment
Linearity 0.02 % of full scale
Shunt calibration Solid state relay on board
Output ±5 Vdc
Output current 2 mA max.
Signal-to-noise ratio 65 db
dc power supply rejection ratio
> 110 db
OPTION CODES
2-pole active filter
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Filter setting 1 Hz 50 Hz3 Hz 100 Hz5 Hz 300 Hz10 Hz 500 Hz20 Hz 1000 Hz30 Hz
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008834-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model UV Bridge Based Sensor In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Bridge Based Sensor In-Line AmplifierModel UV-10
DESCRIPTIONThe Model UV-10 amplifier supplies a highly regulated bridge
excitation voltage for the transducer and converts the millivolt
signal of the transducer to a ±10 Vdc signal. The Universal In-
line features two selectable exciation voltages, programmable
gain settings, a wide adjustment range on the zero, and a buff-
ered solid-state shunt cal relay for quick calibration.
FEATURES• Strain gage sensor amplifier
• ±10 Vdc three-wire output
• 3 V, 5 V, or 10 V excitation voltages @ 70 mA
• 18 Vdc to 32 Vdc supply voltage
• NEMA 4 housing
• Increases signal-to-noise ratio in noisy environments
• Effects of voltage drops in excitation sources are eliminated
• Signals may be sent to the data systems from low impe-
dence sources
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model UV-10
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic or painted Aluminum
Mounting Use #6 or #8 screws
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -15 °C to 71 °C [5 °F to 160 °F]
Sealing IP66 or NEMA 4
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer excitation 3 Vdc, 5 Vdc or 10 Vdc @ 50 mA
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 18 Vdc to 32 Vdc
Current draw 60 mA
Frequency response (-3 dB) dc: 7000 Hz with 350 ohm bridge
dc: 5000 Hz with 5000 ohm bridge
Rise time (0 % to 90 %) 54 ms with 350 ohm bridge
78 ms with 5000 ohm bridge
Zero adjustment range, coarse
±30 %
Zero adjustment range, fine ±15 %
Span adjustment range 1 mV/V to 20 mV/V, ±25 % fine
Linearity 0.02 % of full scale
Shunt calibration Solid state relay on board
Output ±10 Vdc
Output current 2.5 mA
Signal-to-noise ratio 65 db
dc power supply rejection ratio
> 110 db
OPTION CODES
2-pole active filter
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Filter setting 1 Hz 50 Hz3 Hz 100 Hz5 Hz 300 Hz10 Hz 500 Hz20 Hz 1000 Hz30 Hz
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008833-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model UV-10 Bridge Based Sensor In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Bridge Based Sensor In-Line AmplifierModel U3W
FEATURES• Strain gage sensor amplifier
• 18 Vdc to 32 Vdc supply voltage
• NEMA 4 housing
• Selectable excitation voltages: 3 V or 5 V @ 70 mA
• 4-20 mA analog output
• Increases signal-to-noise ratio in noisy environments
• Effects of voltage drops in excitation sources are eliminated
• Signals may be sent to the data systems from low impe-
dence sources
DESCRIPTIONThe Model U3W amplifier supplies a highly regulated bridge
excitation voltage for the transducer and converts the millivolt
signal of the transducer to a 4 mA to 20 mA three-wire current
output signal. The Universal In-line features two selectable exci-
tation voltages, programmable gain settings, a wide adjustment
range on the zero, and a buffered solid-state shunt cal relay for
quick calibration.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model U3W
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic or painted Aluminum
Mounting Use #6 or #8 screws
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -15 °C to 71 °C [5 °F to 160 °F]
Sealing IP66 or NEMA 4
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer excitation 3 Vdc or 5 Vdc @ 70 mA
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 18 Vdc to 32 Vdc
Current draw 70 mA
Frequency response (-3 dB) dc: 7000 Hz with 350 ohm bridge
dc: 5000 Hz with 5000 ohm bridge
Rise time (0 % to 90 %) 54 ms with 350 ohm bridge
78 ms with 5000 ohm bridge
Zero adjustment range, coarse
±70 %
Zero adjustment range, fine ±25 %
Span adjustment range 0.5 mV/V to 6.6 mV/V ±25 % fine adjust-ment
Linearity 0.02 % of full scale
Shunt calibration Solid state relay on board
Signal output 4 mA to 20 mA (three-wire)
Signal-to-noise ratio 65 db
dc power supply rejection ratio
> 110 db
OPTION CODES
2-pole active filter
Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Filter setting 1 Hz 50 Hz3 Hz 100 Hz5 Hz 300 Hz10 Hz 500 Hz20 Hz 1000 Hz30 Hz
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008831-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model U3W Bridge Based Sensor In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Bridge Based Sensor In-Line AmplifierModel U2W
FEATURES• Strain gage sensor amplifier
• 8 Vdc to 32 Vdc supply voltage
• NEMA 4 or IP66 housing
• Constant voltage mode: 5 Vdc @ 2 mA max. (3K to 10K
Ohm)
• Constant current mode: 0.5 mA with 3 V compliance (2K to
6K Ohm)
• Lightning protection
• 4-20 mA two-wire analog output
• Increases signal-to-noise ratio in noisy environments
• Effects of voltage drops in excitation sources are eliminated
• Signals may be sent to the data systems from low impe-
dence sources
DESCRIPTIONThe Model U2W amplifier supplies a highly regulated bridge
excitation voltage for the transducer and converts the millivolt
signal of the transducer to a 4 mA to 20 mA two-wire current
output signal.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model U2W
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Number of channels 1
Case material Plastic or painted Aluminum
Mounting Use #6 or #8 screws
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -29 °C to 70 °C [-20 °F to 158 °F]
Sealing IP66 or NEMA 4
Lightning protection Yes
TRANSDUCER INTERFACE
Characteristic Measure
Transducer type Bridge-based sensor
Transducer bridge excitation and resistance
Constant voltage mode 5 Vdc @ 2 mA max.; 3K ohm to 10K ohm
Constant current mode 0.5 mA with 3 V compliance; 2K ohm to 6K ohm
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Supply voltage 8 Vdc to 32 Vdc
Frequency response 1 kHz @ 2 mV/V
Zero adjustment range ±15 % fine
Span adjustment range Jumper selectable and ±20 % fine adjustment
Shunt calibration Solid state relay on board
Signal output 4 mA to 20 mA (two-wire)
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
95,76 mm [3.77 in]
93,98 mm [3.7 in]
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008830-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model U2W Bridge Based Sensor In-Line Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Charge AmplifierModel CA2/CA3
DESCRIPTIONCharge-mode piezo-electric transducers require charge ampli-
fiers to convert their output to useful levels. Honeywell in-line
charge amplifiers are versatile and convenient solutions for the
use of charge-mode piezo-electric transducers.
FEATURES• Piezo-electric accelerometer amplifier
• ±15 Vdc or 24 Vdc to 32 Vdc supply
• NEMA 4 housing
• Programmable sensitivity
• ±5 V RMS max. output
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model CA2/CA3
POWER REQUIREMENTS
Characteristic Measure
Input voltage ±15 Vdc or 24 Vdc to 32 Vdc
Input current 20 milliamperes
AMPLIFIER CHARACTERISTICS
Characteristic Measure
Sensitivity Programmable (0.05 mV/pc to 6.4 mV/pc)
Input range 780 pc to 100000 pc
Output ±5 V RMS max.
Frequency response, Model CA2
3 Hz to 30 kHz (-3 db)
Frequency response, Model CA3
dc to 30 kHz
Time constant, Model CA2 50 milliseconds
Time constant, Model CA3 2000 seconds
Short circuit protected +output to -output
PHYSICAL CHARACTERISTICS
Characteristic Measure
Size (L x W x H) 9,7 cm x 6,4 cm x 5,6 cm [3.8 in x 2.5 in x 2.2 in]
Temperature, operating 0 °C to 82 °C [32 °F to 180 °F]
Environmental protection Moisture and dust resistant painted aluminum box
Method of connection input Terminal strip inside of box
Sensor connection Miniature coaxial connector
Mounting Recessed screws, outside of the sealed volume
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAM
Not RoHS compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008820-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model CA2/CA3 Charge Amplifier
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
IEPE Accelerometer Power SupplyModel CC2
DESCRIPTIONFor use with IEPE-based accelerometers, the Model CC2 is bat-
tery powered with a low battery indicator. The power supply uses
9 Vdc batteries and has an adjustable drive current.
FEATURES• Constantcurrentpowersupply
• UsedwithIEPEaccelerometers
• Adjustabledrivecurrent
• Batteryoracpowered
• 10Voutput
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model CC2
POwER REqUIREmENTS SPECIFICATIONS
Characteristic measure
Batteries 9 V alkaline (3)
Batterylife 110hrs@2mA
Low battery indicator LEDlightsatapproximately17.5V
INPUT ChARACTERISTICS SPECIFICATIONS
Characteristic measure
Current to transducer Adjustable1.5mAto10mA
Input connector Miniaturecoaxial
OUTPUT ChARACTERISTICS SPECIFICATIONS
Characteristic measure
Gain Unity
Couplingtimeconstant 2seconds(1mOhmload)
Load impedance >100K
Outputconnector BNC
Output 10Vpeaktopeakmax.
PhySICAl ChARACTERISTICS SPECIFICATIONS
Characteristic measure
Size(LxWxH) 13cmx9,4cmx5,7cm[5.12inx3.7inx2.24in]
Temperature 0°Cto66°C[32°Fto150°F]
mOUNTINg DImENSIONS AND ChARACTERISTICS
TyPICAl SySTEm DIAgRAm
89,91 mm [3.54 in]
154,94 mm [6.1 in]
50,03 mm [1.97 in]
Forreferenceonly
NotRoHScompliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008821-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model CC2 IEPE Accelerometer Power Supply
warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determinethesuitabilityoftheproductintheapplication.
Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
wARNINgPERSONAl INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
wARNINgmISUSE OF DOCUmENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
for Amplified TransducersDC Power Supply
DESCRIPTIONProvides regulated voltages ranging from 10 Vdc to 28 Vdc and
output currents to 600 milliamps. Terminal strip connections
eliminate soldering. Features include short-circuit protection,
encapsulated construction and conservative design aimed at
providing long-term stability. Power supplies may be used in
series. No derating or heat sinking required.
FEATURES• Regulated
• Miniaturesize
• Terminal-stripconnection
• Long-termstability
• Short-circuitconstruction
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
DC Power Supply
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Input voltage 105Vacto125Vac,47Hzto420Hz,single phase
Output specifications see order codes table
Output voltage trim adjustment
Outputs are factory set to ±1 % of nomi-naloutputvoltage.Singleoutputmodelsmay be trimmed to the nominal output voltage with an external trim resistor
Polarity Either positive or negative terminal of a single output module may be grounded. Dual output modules have a positive/common/negative output terminal con-figuration
Impedance 0.07ohmat1kHz(approx.)0.2ohmat10kHz(approx.)
Regulation,line ±0.05 %
Regulation,load ±0.1 %
Ripple 1mVRMS
Optional 230 Vac input For operation on an input of 230 Vac, 46 Hzto420Hz
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, ambient operating
32°Cto66°C[0°Fto150°F]
Temperature, storage -55°Cto85°C[-67°Fto185°F]
Temperature error 0.008 % full scale/°F nominal
MOUNTINg DIMENSIONS AND ChARACTERISTICS
For reference only
NotRoHScompliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985 Douglas Drive North
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008808-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
DC Power Supply for Amplified Transducers
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
AC Carrier or DC Strain Gage Conditioner Indicator
Model 7541
DESCRIPTIONThese advanced instruments provide engineering unit display
of a strain gage (mV/V) input and a frequency input. They also
compute power and perform 21 functions including limit checks,
tare, hold and max./min. capture. You needn’t write code or add
hardware to be up and running a productive test.
The alphanumeric readout can display measured and computed
data, units of measure, and test status. During setup, it guides
you with English language prompts. There are no manual adjust-
ments. To calibrate, enter the full scale value in engineering units
and auto-cal takes over. Provides 0.01 % (max.) resolution and
±5 V and/or ±10 V analog outputs at full scale. The keyboard ac-
cesses measured data, held data, max./min. data, data spread,
limit status, and/or I/O status without disruption. Password pro-
tection may be used, if needed.
FEATURES• Maybecalibratedintwodirections(clockwiseandcounter-
clockwise or tension and compression)
• Fast,rock-solidreadingswithhighnoiseimmunity-2000
samples/sec for torque, head, or drawbar force input - 1 ms
response for speed
• Oneortwochannelinput
• Six-digitengineeringunitwithlegendsand0.01%resolu-
tion max.
• RS-232,RS-422,RS-485serialcommunication
• Auto-scaled±5Vand/or±10Vanalogoutputs
• Nopots,batteries,fans,maintenance,orexternalpower
supplies
• Excitation:accarriermodels,3.28kHz,3Vrms;dcmodels,
5 V or 10 V dc, user selectable
• CEapproved
fix other pages with ac or dc
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model 7541
GENERAl SPECIFICATIONS
Characteristic Measure
Straingageinput Any80ohmto2Kohmtransducer,di-rectlywiredortransformercoupled.4,6,or 7 wire circuits are accommodated
Transducer excitation, ac models
3Vrms,3.28kHz±0.01%sinewave.Regulatedandshortcircuitprotected
Transducer excitation, dc models
5 V or 10 V dc, user selectable, regu-lated
Sensitivity 1.0mV/Vto4.5mV/Vwith50%over-range;automaticallyscaled
Input resistance 100mohminparallelwith33pF
Automaticnull InPhase:±10%offullscale(with50%overrange),±60%offullscale(with0%overrange).Quadrature:±1mV/V
Autocalibration Dual polarity shunt calibration with provi-sionforCALresistorfeedback
Spurioussignalrejection 60Hz:120dBcommonmode,100dBnormalmode.Carrierquadrature:60dB
Anti-aliasfilter 200Hz,7-poleBesselresponsefilter
Low-passfiltering Four-poleBesselresponsedigitalfilterwith11cutofffrequenciesfrom0.1Hzto200Hzin1-2-5steps
ENVIRONMENTAl SPECIFICATIONS
Characteristic Measure
Temperatureeffects,zero ±0.001%offullscale/°Fmax.
Temperature effect, span ±0.001%offullscale/°Fmax.
Frequencyinput Anyunidirectionalorbidirectional(quadrature) source including self-generatingandzerovelocitymagneticpickups, optical encoders, flowmeters, etc. When used with bidirectional sen-sors, the conditioner outputs both direc-tion and magnitude
Input impedance and configuration
Differential or single ended inputs. 100 kohm differential, 50 kohm single ended
Input threshold (keypad selectable)
10, 20, 50, 100 or 200 mV pk-pk (be-tweeninputs)orTTL
Maximumvoltage ±130Vdcor130Vrms
Input signal bandwidth 0.001kHzto200kHz(10mVto200mVpk-pkthreshold)0.001kHzto400kHz(TTLthreshold)
Display ranges and resolution
Rangeless(useanyfullscaleengineer-ing unit value) with 50 % overrange. Resolutionis0.01%offullscale
Lowpassfilter(keypad selectable)
20kHz(-3dB)ornone(thisfilterisnotavailableforTTLinputs)
Responsetime Greaterof:1ms,typ(2msworstcase)or the input pulse length
Commonmoderejection 80dB(60Hz),55dB(0kHzto10kHz)
Lowpassfilteringofsampled data
Unfilteredorfour-poleBesselfilter.Cut-offfrequenciesfrom0.1Hzto100Hzin1-2-5 steps
Overall accuracy 0.01%offullscale@25°C[77°F],0.015%offullscale@5°Cto50°C[41°Fto122°F]
Excitation supplies 12V@[email protected](currentlimitandovervolt-age (fuses) protected
Maximumtransducercable length
500 ft, except 200 ft for 100 ohm or lower strain gage transducers
ElECTRICAl SPECIFICATIONS
Characteristic Measure
Signal-to-noiseratio1 With1/10/100/200Hzfilters86/76/66/62dB@1mV/Vfullscaleand86/80/72/66dB@5mV/VFS
Resolution 0.01 % of full scale
Overall accuracy @ 25°C[77ºF]
0.02 % of full scale, worst case.
DISPlAY SPECIFICATIONS
Characteristic Measure
Systemdisplay Twolineby16alphanumericcharac-ters,each0.2inwideby0.3inhigh.BacklitLCDwithadjustablecontrast
Views Selecteithertwochannels,oneChannelwith limit status or one channel with I/O status
Data displayed Selectfromcurrent,max.,min.,spread,held data and tare value
Data format Engineering units with six digits (1-2-5 format) and five character, upper or lower case, user-entered legend/de-scriptor
SYSTEM RESPONSE (PER ChANNEl) SPECIFICATIONS
Characteristic Measure
Data samp. & max./min. update rates
2000Hz(hardwarechannels),50Hz(CH3calculation)
Limitcheckingrate 1000Hz(hardwarechannels),50Hz(CH3calculation)
LogicI/Oresponsetime 1ms(hardwarechannels),20ms(CH3calculation)
Update rate for each analog output
1000Hz
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
AC Carrier Strain Gage Conditioner Indicator
MEChANICAl SPECIFICATIONS
Characteristic Measure
Size(WxHxD) 165,1mmx73,66mmx220,98mm[6.5inx2.9inx8.7in]
Weight 3lb
Operating temperature 5°Cto50°C[41°Fto122°F]
Input power 90Vacto250Vac,50/60Hz@25VA,max.Two2A/250Vfuses,linefilterandrear power switch
SYSTEM SPECIFICATIONS
Characteristic Measure
Systemcontrol AllI/Ofunctionscanbeorderedinanycombination. The pattern function adds ANDingcapabilities
Input actions/channel Logicinputs,outputsandinternalMatrixsignalscontrolthefollowingactions:tare, clear tare, hold, clear hold, reset max./min., clear latched limits, check limits,domax./mins.,apply+CAL
Output events/channel The following events drive logic outputs andinternalMatrixsignals:HIlimit,NOTHIlimit,INlimit,NOTINlimit,LOlimit,NOTLOlimit,atmax.,NOTatmax.,atmin.,NOTatmin.
Three user-defined patterns Patterns of logic inputs, outputs and MatrixsignalsdriveLogicoutputsandinternalMatrixsignals
LimitChecking EachchannelhasaHIandLOlimitwhich may be latched or unlatched, absolute or signed, and with or without hysteresis.Selecteithercurrent,max.,min. spread or held data for limit checking.Limitviolationsonanyorallchannels can be set to trigger back-light flashing in any of the display view modes
lOGIC INPUTS SPECIFICATIONS
Characteristic Measure
FourLogicinputs Each with programmable destination, protectedto±130Vdcor130Vrms
FourLogictype TTLcompatible,ScmittTrigger,low-truewith47kohmpull-up.Inputcurrentis-100µA@0V
SixLogicoutputs Each with programmable source, short circuit (current and thermal limits) and overvoltage (fuse) protected.
SixLogictype Open collector, low-true. Operating @ 24V(max.)and0.3Amaxsinkcurrent
External +5 Vdc power (on I/O conn.)
250mA,shortcircuit(currentlimit)andovervoltage (fuse) protected.
Serialcommunicationport (selectableasRS232,RS422orRS485)Supports32devicesonRS485portand1deviceonRS232/422
Baudrate 300to38400.Maximumcablelength:4000ft(RS422/RS485),50ft(RS232)
120 ohm terminal resistors (RS485)
UserselectableforRXDandTXD
RS422/485transceivers Slew-ratelimited,shortcircuitprotected(current and thermal limits)
RS232drivers Shortcircuitprotected(currentlimit)
SerialI/Os Use a nine-pin D connector. ±15 kV ESDprotectedandfloat(100kohm)with respect to earth ground
Commands Controlofallmodes,settingsandmeas-urements
Non-volatilememorystorage settings
EEPROM,batteriesarenotused
Dual analog outputs Each assignable to any of the three channels are short circuit (current limit) and overvoltage (fuse) protected
Output impedance/min. load resis.
< 1 ohm/10 kohm
Fullscale ±5Vor±10V(userselectable).Resolu-tionis2mV@±5Vfullscaleor4mV@±10 V full scale
Overrange ±8.2V@±5Vfullscaleor±13.5V@±10 V full scale
Nonlinearity ±2mV@±5Vfullscaleor±4mV@±10 V full scale
Overall error
(worst case, incl. temp. effects)
±5 mV @ ±5 V full scale or ±10 mV @ ±10 V full scale
Filter 100Hz,5poleBesselresponselowpass filter
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008816-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 7541 AC Carrier Strain Gage Conditioner Indicator
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAl INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Notes
1.Theratioexpressedindecibels(dB),offullscale(FS)tonoisespread.Measurementsaremadeforaone-minuteintervalusinga350ohmbridge.
2.Bothexcitationvoltagescanbeusedsimultaneouslywiththefollowingrestrictions:4.8x(12Vcurrent)+(5Vcurrent)<700mA;12Vcur-rent<125mA;5Vcurrent<250mA.
3.Appliestostraingagechannelonly.Frequencymeasurementisabsolute with enhanced accuracy and only requires user engineering unit scale.
4.Specificationissubjecttochangewithoutnotice.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Transducer Display and Signal Conditioning Unit
Model SC1000/SC2000
DESCRIPTIONThe SC series models are self-calibrating microprocessor-
based transducer signal conditioners when used with sig mod
equipped transducers. Indicators are available with several dif-
ferent types of input channels and output channels. When used
with unamplified strain gage transducers that have the signature
calibration module installed, these instruments will completely
self calibrate zero, span, decimal point, and engineering units
automatically.
Input channels are available for a variety of transducers. Each
input channel includes an excitation power supply and either an
isolated voltage or isolated current analog output.
• Unamplifiedpressureorload
• Pressureorloadwithinternalvoltageamplifiers
• Pressureorloadwithinternalorexternaltwo-wire
current amplifiers
• ac/acdisplacementtransducer
• dc/dcdisplacementtransducer
•RTDtemperatureprobes(Pt100)
AvailableoutputchannelsfortheSC2000include:
• Contactrelaysforthefourstandardlimitsoradditionallimits
(max.16limits/chassis)
• Isolateddigital-to-analogvoltage(±5Vdcor0Vdcto10Vdc)
orcurrent(4mAto20mA)
In addition to the physical input and output channels, up to
seven virtual channels can be configured to assist in many po-
tential applications.
Four channel chassisThemodelsSC1000andSC2000canholduptofourphysi-
calchannelsintheir3/8DINAluminumbench-topchassis.A
bright,dual-line16-characterdisplaycandisplay5,6or7
numeric digits; simply press a button to select the next channel
to be viewed. If configured for split-screen operation, up to four
channelvaluescanbedisplayedatthesametime.TheSC2000
includesfouropencollectorlimit(alarm)outputspluspeakand
valley detection.
FEATURES• Onetofourchannels
• ±6digitdisplay
• “Sigcal”autosetup
• Upto800Hzfrequencyresponse,fieldselectable
• Pressure,load,displacementtransducer,voltage,current,
strain gage based sensor input
• Alarmoutputs
• CEapproved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model SC1000/SC2000
GENERAl SPECIFICATIONS
Characteristic Measure
Model SC1000/SC2000
Numberofphysicalchannels
1to4
Numberofvirtualchannels 1to7
Case material Aluminum
Form factor 3/8DIN
Mounting Bench(standard)
Size(WxHxD) 142,24mmx71,12mmx222,25mm[5.6inx2.8inx8.75in]
Weight 1,81kg[4lb]
COMMUNICATIONS SPECIFICATIONS
Characteristic Measure
Serial setup and output RS-232/RS-485
Isolation 500V
Max. baud rate 38400
POwER SPECIFICATIONS
Characteristic Measure
Standard ac powered 100Vacto230Vac,47Hzto63Hz
Excitation drive 120mAmax.
DISPlAy SPECIFICATIONS
Characteristic Measure
Numberofdisplays 1
Numberoflines/display 2
Numberofcharacters/line 16
Scaling Automatic or manual setup
Max. display count 9999999
Decimalpointselection 0to5
Displaytype Vacuum/Fluorescent
ENvIRONMENTAl SPECIFICATIONS
Characteristic Measure
Temperature, storage -29°Cto93°C[-20°Fto200°F]
Temperature, operating 4°Cto41°C[40°Fto105°F]
SPECIAl FEATURES (SC2000 ONly) SPECIFICATIONS
Characteristic Measure
Limits setup Front panel
Limits output, standard Open-collector
Limits output, relay output channel
Contact relays
Limits quantity 4std.,16max.(contactrelays)
Peak/valleyholdoninputchannels
Yes
Digital,isolatedcontrolinputs
4
Approvals CEapproved(exceptvehiclepoweredunit)
Interfaces Signature calibration
INPUT AMPlIFIER CARDS
NotRoHScompliant
Input Strain gage millivolts
High level volts/mA
RTD mil-livolts
ac/ac dis-placement transducer
Transduc-er type
Unamplifiedsensors
Amplified pressure or load,dc/dc dis-placement transducer
Platinum100ohm,alpha = 0.00385
ac/acdis-placement transducer
Ranges* 0.5mV/Vto11mV/[email protected]/Vto5.5mV/V@10V
±5Vdcor±10Vdc,4mAto20mA
-200°Cto800°C[-328°Fto1472°F]
0.1VRMSto15VRMS
Frequency response
See table below
See table below
See table below
See table below
Resolu-tion
See table below
See table below
See table below
See table below
Calibra-tion type
Shunt; mV/V;2-,3-,or5-pointknownload
Shunt; 2-, 3-,or5-pointknownload
2-, 3-, or 5-pointknownload
2-, 3-, or 5-pointknownload
Trans-ducer excitation
5Vdcor10Vdcwithsense
±15Vdc,28Vdc,or12Vdc
10Vdc 3Vac@3kHz
Push but-ton 100 % tare
Yes Yes N/A Yes
Push but-ton shunt test
Yes Yes N/A Yes
*Rangesarefieldprogrammable,exceptforRTDinput
All input cards include non-isolated, open collector control inputs that can be field configuredforanyoneofthefollowingfunctions:1)trackhold,2)peak/valleyhold,3)tareon,and4)tareoff.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
Transducer Display and Signal Conditioning Unit
MOUNTING DIMENSIONS AND CHARACTERISTICS
TyPICAl SySTEM DIAGRAM
FlExIblE AND ExPANDAblE PlATFORM OPTIONS
For reference only
Resolution (counts) (not including min. 10 % overrange/underrange capability)
Fre-quency response (Hz) field selectable
Step response (ms) typi-cal
Strain gage/RTD
High level ac/ac displace-ment trans-ducer
2(fastmode)
40 ±50000 ±50000 ±25000
2 440 ±50000 ±50000 ±25000
8 110 ±25000 ±25000 ±15000
16 55 ±20000 ±25000 ±10000
32 28 ±10000 ±20000 ±10000
50 16 ±5000 ±15000 ±5000
100 8 ±5000 ±10000 ±5000
250 3 ±2000 ±10000 ±2000
500 2 ±2000 ±4000 ±2000
800 2 ±2000 ±2500 ±2000
OUTPUT
Output Strain gage millivolts
High level volts/mA
RTD mil-livolts
ac/ac displace-ment trans-ducer
voltage range (field selectable)
5Vdc,±5Vdc,10Vdc,±10Vdc
5Vdc,±5Vdc,10Vdc,±10Vdc
5Vdc,±5Vdc,10Vdc,±10Vdc
5Vdc,±5Vdc,10Vdc,±10Vdc
Current range
4mAto20mA
4mAto20mA
4mAto20mA
4mAto20mA
Source Any chan-nel
Any chan-nel
Any chan-nel
Any chan-nel
Isolation 500V 500V 500V 500V
Resolution 13bits 13bits 13bits 13bits
Frequency response
Same as input
Same as input
Same as input
Same as input
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
4Honeywell•SensingandControl
Model SC1000/SC2000
Front panel or remote tare Flexible user setup
mv/v or shunt calibration or five-point calibration Remote setup
User selectable display options Different alarm configurations
User selectable filtering Group and individual channel remote inputs
SC2000 CAPAbIlITIES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl5
Transducer Display and Signal Conditioning Unit
Open collector alarms or via optional four-relay cards Optional math channel can act like PlC
Sig cal auto setup Analog and digital outputs
SC2000 CAPAbIlITIES
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008826-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model SC1000/SC2000 Transducer Display and Signal Conditioning Unit
warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
wARNINGPERSONAl INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
wARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Portable Transducer Display and Signal Conditioning Unit
Model SC2001
DESCRIPTIONThe SC series models are self-calibrating microprocessor-
based transducer signal conditioners when used with sig mod
equipped transducers. Indicators are available with several dif-
ferent types of input channels and output channels. When used
with unamplified strain gage transducers that have the signature
calibration module installed, these instruments will completely
self calibrate zero, span, decimal point, and engineering units
automatically. The Model SC2001 includes all the features of the
SC2000 in a portable, rugged enclosure.
Input channels are available for a variety of transducers. Each
input channel includes an excitation power supply and either an
isolated voltage or isolated current analog output.
• Unamplifiedpressureorload
• Pressureorloadwithinternalvoltageamplifiers
• Pressureorloadwithinternalorexternaltwo-wire
current amplifiers
• ac/acdisplacementtransducer
• dc/dcdisplacementtransducer
•RTDtemperatureprobes(Pt100)
Available output channels for the SC2001 include:
• Contactrelaysforthefourstandardlimitsoradditionallimits
(max.16limits/chassis)
• Isolateddigital-to-analogvoltage(±5Vdcor0Vdcto10Vdc)
orcurrent(4mAto20mA)
In addition to the physical input and output channels, up to
seven virtual channels can be configured to assist in many po-
tential applications.
Four channel chassisThe model SC2001 can hold up to four physical channels in
their3/8DINAluminumbench-topchassis.Abright,dual-line
16-characterdisplaycandisplay5,6or7numericdigits;simply
press a button to select the next channel to be viewed. If con-
figured for split-screen operation, up to four channel values can
be displayed at the same time. The SC2000 includes four open
collectorlimit(alarm)outputspluspeakandvalleydetection.
FEATURES• PortablemountingforSC2000
• Vehiclepoweroracpowerinput
• Easyhookupofsensors
• Pressure,load,displacementtransducervoltagecurrent,
strain gage based sensor input
• Convenientcablestorage
• CEapproved
insertcorrectpicturefromIN-2
product in case
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008827-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model SC2001 Transducer Display and Signal Conditioning Unit
GENERAl SPECIFICATIONS
Characteristic Measure
Model SC2001
Case material Aluminum
Form factor Suitcase
Mounting Portable
Size(WxHxD) 33,7cmx29,2cmx23,4cm [13.25inx11.5inx9.2in]
MOUNTING DIMENSIONS AND ChARACTERISTICS
For reference only
Warranty. Honeywell warrants goods of its manufacture as beingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAl INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
See SC2000 data sheet for specification of: display, environmental, spe-cial features, communications, power, input amplifier cards, capabilities, options, and system diagram.
NotRoHScompliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Transducer Display and Signal Conditioning Unit
Model SC3004
DESCRIPTIONThe SC series models are self-calibrating microprocessor-based
transducer signal conditioners. Indicators are available with
several different types of input channels and output channels.
When used with unamplified strain gage transducers that have
the signature calibration module installed, these instruments will
completely self calibrate zero, span, decimal point, and engi-
neering units automatically.
Input channels are available for a variety of transducers. Each
input channel includes an excitation power supply and either an
isolated voltage or isolated current analog output.
• Unamplifiedpressureorload
• Pressureorloadwithinternalvoltageamplifiers
• Pressureorloadwithinternalorexternaltwo-wirecurrent
amplifiers
• ac/acdisplacementtransducer
• dc/dcdisplacementtransducer
• RTDtemperatureprobes(Pt100)
AvailableoutputchannelsfortheModelSC3004include:
• Contactrelaysforthefourstandardlimitsoranadditionalfour
limitspercard,upto16limits
• Isolateddigital-to-analogvoltage(±5Vdcor0Vdcto10Vdc)
orcurrent(4mAto20mA)
In addition to the physical input and output channels, up to eight
virtual channels can be configured to assist in many potential
applications.
Fourteen channel chassisModelSC3004canholdupto14physicalchannelsinits19in,
2Urack-mountenclosure.Uptothreequad-linedisplayscanbe
installedwhichwilldisplaythevaluesofupto12channels.Split
displays can increase display capacity.
FEATURES• Oneto14channels
• ±6digitdisplay
• “Sigcal”autosetup
• Upto800Hzfrequencyresponse,fieldselectable
• Pressure,load,displacementtransducer,voltage,current,
strain gage based sensor input
• Alarmoutputs
• CEapproved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model SC3004
GENERAl SPECIFICATIONS
Characteristic Measure
Model SC3004
Number of physical channels
1to14
Number of virtual channels 8
Case material Aluminum
Form factor 2Urack
Mounting Rackorbenchwithincludedrubberfeet
Size(WxHxD) 482,6mmx88,9mmx222,25mm[19inx3.5inx8.75in]
Weight 4,99kg[11lb]
DISPlAy SPECIFICATIONS
Characteristic Measure
Number of displays 1,2,or3(max.12channeldisplay)
Numberoflines/display 4
Numberofcharacters/lines 20
Scaling Automatic or manual setup
Max. display count 9999999
Decimalpointselection 0to5
Displaytype Vacuum/Fluorescent
SPECIAl FEATURES SPECIFICATIONS
Characteristic Measure
Limits setup Front panel
Limits output, standard Open-collector
Limits output, relay output chan.
Contact relays
Limitsquantity 4std.,16max.(contactrelays)
Peak/valleyholdoninput chan.
Yes
Digital,isolatedcontrolinputs
4
Approvals CE approved
COMMUNICATIONS SPECIFICATIONS
Characteristic Measure
Serial setup and output RS-232/RS-485
Isolation 500V
Max. baud rate 38400
POwER SPECIFICATIONS
Characteristic Measure
Standard ac powered 100Vacto230Vac,47Hzto63Hz
Excitation drive 400mAmax.
ENvIRONMENTAl SPECIFICATIONS
Characteristic Measure
Temperature, storage -29°Cto93°C[-20°Fto200°F]
Temperature, operating 4°Cto41°C[40°Fto105°F]
INPUT AMPlIFIER CARDS
NotRoHScompliant
Input Strain gage mil-livolts
High level volts/mA
RTD mil-livolts
ac/ac displace-ment trans-ducer
Transduc-er type
Unamplifiedpressure or load sen-sors
Amplified pressure or load,dc/dcdisplace-ment trans-ducer
Platinum100ohm,alpha = 0.00985
ac/acdis-placement transducer
Ranges* 0.5mV/Vto11mV/[email protected]/Vto5.5mV/V@10V
±5Vdcor±10Vdc,4mAto20mA
-328°Fto1472°F
0.1VRMSto15VRMS
Frequency response
See table on page 3
See table on page 3
See table on page 3
See table on page 3
Resolu-tion
See table on page 3
See table on page 3
See table on page 3
See table on page 3
Calibra-tion type
Shunt; mV/V;2-,3-,or5-pointknownload
Shunt; 2-,3-,or5-pointknownload
2-,3-,or5-pointknownload
2-,3-,or5-pointknownload
Transduc-er excita-tion
5Vdcor10Vdcwithsense
±15Vdc,28Vdc,or12Vdc
10Vdc 3Vac@3kHz
Push button 100 % tare
Yes Yes N/A Yes
Push button shunt test
Yes Yes N/A Yes
*Rangesarefieldprogrammable,exceptforRTDinput
All input cards include non-isolated, open collector control inputs that can be field configuredforanyoneofthefollowingfunctions:1)trackhold,2)peak/valleyhold,3)tareon,and4)tareoff.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
Transducer Display and Signal Conditioning Unit
MOUNTING DIMENSIONS AND CHARACTERISTICSOUTPUT
TyPICAl SySTEM DIAGRAM
FlExIblE AND ExPANDAblE PlATFORM
For reference only
Resolution (counts) (not including min. 10 % overrange/underrange capability)
Fre-quency response (Hz) field selectable
Step response (ms) typi-cal
Strain gage/RTD
High level ac/ac displace-ment trans-ducer
2(fastmode)
40 ±50000 ±50000 ±25000
2 440 ±50000 ±50000 ±25000
8 110 ±25000 ±25000 ±15000
16 55 ±20000 ±25000 ±10000
32 28 ±10000 ±20000 ±10000
50 16 ±5000 ±15000 ±5000
100 8 ±5000 ±10000 ±5000
250 3 ±2000 ±10000 ±2000
500 2 ±2000 ±4000 ±2000
800 2 ±2000 ±2500 ±2000
Output Strain gage mil-livolts
High level volts/mA
RTD mil-livolts
ac/ac displace-ment trans-ducer
voltage range (field se-lectable)
5Vdc,±5Vdc,10Vdc,±10Vdc
5Vdc,±5Vdc,10Vdc,±10Vdc
5Vdc,±5Vdc,10Vdc,±10Vdc
5Vdc,±5Vdc,10Vdc,±10Vdc
Current range
4mAto20mA
4mAto20mA
4mAto20mA
4mAto20mA
Source Any chan-nel
Any chan-nel
Any chan-nel
Any chan-nel
Isolation 500V 500V 500V 500V
Resolution 13bits 13bits 13bits 13bits
Frequency response
Same as input
Same as input
Same as input
Same as input
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
4Honeywell•SensingandControl
Model SC3004SC3004 CAPAbIlITIES
Front panel or remote tare Flexible user setup
mv/v or shunt calibration or five-point calibration Remote setup
User selectable display options Different alarm configurations
User selectable filtering Group and individual channel remote inputs
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl5
Transducer Display and Signal Conditioning UnitSC3004 CAPAbIlITIES
Open collector alarms or via optional four-relay cards Optional math channel can act like PlC
Sig cal auto setup Analog and digital outputs
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008828-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model SC3004 Transducer Display and Signal Conditioning Unit
warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
wARNINGPERSONAl INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
wARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Panel Meter - Strain Gage Transducer Indicator
Model 7558
DESCRIPTIONThe Model 7558 series of digital indicators provide enhanced
accuracy, ease of use, and improved resolution of measurement.
These cost-efficient instruments provide a user-selectable dc
excitation voltage to drive strain-gage-based transducers.
These standard meters can be made more powerful through
the selection of optional features that provide the capability to
control external devices, and offer digital communication with
computers.
FEATURES• Strain-gage-based,Wheatstone-bridgetransducer
• Five-digitLEDdisplay
• 1/8DINsize
• Userselectableresolution
• NEMA4X/IP65construction
• Isolatedanalogoutput
• Min.andmax.peakdetection
• 16-pointlinearization
• CEapproved
OPTIONS• Duallimitrelays
• RS232orRS485isolatedserialinterface
• DeviceNetsoftware
• PCsoftwareformeterconfiguration
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model 7558
DISPlAy SPECIFICATIONS
Characteristic Measure
A/Dconverter 16-bitresolution
Resolution Selectableby1,2,5,or10counts
Range -19999to19999
Decimalpoint Selectableposition
A/Dconversionrate 20readings/sec
Updaterate 1to20updates/sec
SENSOR INPUT SPECIFICATIONS
Characteristic Measure
Range ±24mVdcor±240mVdc
Accuracy ±0.02%ofreading
Impedance 100mohm
POwER SUPPly SPECIFICATIONS
Characteristic Measure
ac supply voltage 85Vacto250Vac,50Hz/60Hz,15VA
dc supply voltage 11Vdcto36Vdc,11W
USER CONFIgURAblE lINEARIzATION SPECIFICATIONS User-definedlinearizationfunctionasa16-pointpiece-wiselinearapproximation
ANAlOg OUTPUT SPECIFICATIONS
Characteristic Measure
Voltage 0Vdcto10Vdc
Impedance 500ohm
Accuracy ±0.17%fullscale(18°Cto28°C[64°Fto82°F])
DUAl lIMIT RElAyS SPECIFICATIONS
Characteristic Measure
Type TwoformCrelays
Isolation 2000Vrmsfor1minute
Contactrating Totalcurrentwithbothrelaysenergized<5A
RS232 OR RS485 SERIAl OUTPUT SPECIFICATIONS
Characteristic Measure
Datatype 7/8bits
Voltagelevel 50V
Baud rate 19200
Isolation 500Vrms
Addressunits 99max.
Parity No,oddoreven
MOUNTINg DIMENSIONS AND ChARACTERISTICS
ORDER CODES
Forreferenceonly
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008818-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 7558 Panel Meter - Strain Gage Transducer Indicator
warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
wARNINgPERSONAl INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
wARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Process Monitor and ControllerModel 7554
DESCRIPTIONThe Model 7554 is a portable process monitor and control instru-
ment designed to work with Honeywell’s Auto-ID transducers (for
example, Model 1254) for plug-and-play operation.
FEATURES• Continuousprocessmonitoring(tracking)
• Threepeakrecordingfunctions
• Tworecordfunctions(withmultiplesamplingratesfrom1Hz
to10kHzandstorageforupto8000datapoints)
• Threeprocesscontroloutputsignals(forhigh,low,and
target occurrences)
• RS-232output
• Storagecapabilityforupto8000peakreadings
• Fourlogoperationfunctions(viewing,uploading,printing,
and erasing)
• Selectableengineeringunits
• Menulockingfeature
• Automaticpower-down(whensensorisnotpluggedin)
• RechargeableNi-Cadbatteries
• Graphicuserinterfacesoftwareavailable(consultfactory)
• OptionalsimultaneousangleorRPMmeasurements
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008817-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 7554 Process Monitor and Controller
SPECIFICATIONS
Characteristic Measure
Digits Five(withnodecimal)
Height of digits 6,35mm[0.25in]
Samplingrates,track 4Hz
Samplingrates,peak 5kHz
Samplingrates,record Selectableupto10kHz
Frequencyresponse -3dBat1000Hz
Accuracy max. error = 0.05 % of full scale
SENSOR INTERFACE SPECIFICATIONS
Characteristic Measure
Max. input and full scale ±4.5mV/V
Polarity Bi-polar
Bridgeexcitation 7Vsupplied
Bridgeimpedance(min.) 120
D ata output 232portASCII,9600baud,8-N-1
Control/limitoutputs Opencollector
Analog output 0Vdcto2.4Vdc(1Vdc@2mV/V)
Dimensions (W x D X H) [152,4mmx203,2mmx44,45mm]6.0inx8.0inx1.75in
POWER SPECIFICATIONS
Characteristic Measure
ac (adapter supplied) 115Vac
Batteries 9.6Vinternal/rechargeable
Warranty. Honeywell warrants goods of its manufacture as beingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINGPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Demodulator for AC Transducer/Displacement Transducers
Model DM
DESCRIPTIONModel DM, for carrier transducers, is a low-cost bench, panel or
rack-mounted instrument which contains a power supply, signal
conditioner, amplifier (Bipolar 5 V output) and digitizer. The 4
1/2-digit LED display features bright, easy-to-read 14,2 mm [0.56
in] high characters. The compact 1/8 DIN size case measures
9,7 cm W x 4,8 cm H x 13,2 cm D [3.8 in x 1.9 in x 5.2 in]. Wires
easily attach to the rear connector using screw terminals. The
Model DM features a 5 kHz drive supply for the transducer, a
stable signal amplifier and a novel demodulation technique that
produces an enhanced accuracy result.
FEATURES• Used with displacement transducers
• 4 1/2 digit LED display
• 3 conversions per second
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model DM
PHYSICAL SPECIFICATIONS
Characteristic Measure
Weight 0,9 kg [2 lb]
Mounting Bench, rack or panel
Case size (standard) 1/8 DIN
Case material Noryl plastic
Input/output connector Removable with screw terminals
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, storage -29 °C to 93 °C [-20 °F to 200 °F]
Temperature, operating 0 °C to 54 °C [32 °F to 130 °F]
MOUNTINg DIMENSIONS AND CHARACTERISTICS
Not RoHS compliant
TRANSDUCER INTERFACE
Characteristic Measure
Transducer excitation 3 VRMS @ 5 kHz
Type of inputs accepted ac, displacement transducer, VRT
Input gain range < 1 to 300
Calibration methods Manual displacement
Noise and ripple < 300 microvolts
Transducer minimum im-pedance
7 ohm
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Number of characters displayed
4 1/2
Conversions per second 3
Power requirements, standard
115 Vac @ 5 watts
Power requirements, optional
220 Vac, 12 Vdc
Scaling 0-19999
Scaling method Zero and span adjustment
Polarity indication Yes
Decimal point selection Jumper (non-solder)
Display size 14,2 mm [0.56 in]
Overrange indication Flashing display
Display resolution 1/20000 max.
Digital display LED
Analog output ±5 Vdc
Amplifier output impedance < 2 ohm
Accuracy ±0.2 % full scale
Amplifier frequency re-sponse
300 Hz
Common mode rejection 60 db
Scan adjustment, fine > ±15 %
Scan adjustment, coarse > ±80 %
Zero adjustment, fine > ±5 %
Zero adjustment, coarse > ±20 %
Short circuit protected Yes
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Alarm outputs 58a. Hi-lo limits
Display options 58c. Peak/hold58d. Track/hold
Power supply 110 Vac60a. 220 Vac60c. Battery powered (12 Vdc)
Front panel 51d. Custom front panel
Mounting options 51a. Rack mount adapter
95,25 mm[3.75 in]
96,52 mm[3.8 in]
95,25 mm[3.75 in]
Accessories and options dimensions
AA924Bench mountbracket
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008812-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model DM Demodulator for AC Transducer
TYPICAL SYSTEM DIAgRAM Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
FLExIbLE PLATFORM
Reset feature
Mounting optionsPanel mount (standard)Bench mount bracket (AA924)
Peak/hold featureSignal conditioning options(58c.) Peak/hold (not available with alarm or track/hold option(60a.) 220 Vac(60c.) 12 Vdc powered
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Digital Display/Signal ConditionerModel GM-A
DESCRIPTIONThe GM-A is a cost-efficient digital readout that works with
amplified (0 V to 5 V or 4 mA to 20 mA) transducers or transmit-
ters. This unit supplies power to the sensors. Two-wire current is
user jumper selectable for use with two-wire current transducers.
Separate power supply required for three-wire current use. Not
for use with intrinsically safe applications utilizing a barrier.
FEATURES• Highlevel(amplified)transducerinput
• 41/2digitLEDdisplay
• Large14,2mm[0.56in]readout
• Highspeedanalogoutput
• Transducercurrentdrive30mA(max.)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model GM-A
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature,storage -29°Cto93°C[-20°Fto200°F]
Temperature,operating 0°Cto54°C[32°Fto130°F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Number of characters displayed
41/2
Powerrequirements,standard
115Vac@5W
Powerrequirements,optional
220 Vac
Conversionspersecond 3
Scaling method Zero and span adjustment
Polarity indication Yes
Decimalpointselection Jumper (non-solder)
Displaysize 14,2mm[0.56in]
Overrangeindication Flashingdisplay
Displayresolution 1/20000max.
Digitaldisplay LED
Analog output ±5 Vdc
Amplifier output impedance < 2 ohm
Accuracy ±0.03%
Amplifier frequency response
250Hz
Coarsezeroadjustment ±40%
PHYSICAL SPECIFICATIONS
Characteristic Measure
Weight 1kg[2.25lb]
Mounting Bench,rackorpanel(panelmountincluded with unit)
Casesize(standard) 1/8DIN
Casematerial Noryl plastic
Input/outputconnector Removablewithscrewterminal
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Power supply110Vac60a.220Vac
Front panel 51d.Customfrontpanel
Mounting options
51a.Rackmountadaptor51c.NEMAenclosure
NotRoHScompliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
Digital Display/Signal Conditioner
MOUNTINg DIMENSIONS AND CHARACTERISTICS
TYPICAL SYSTEM DIAgRAMFLExIbLE PLATFORM
COMPREHENSIVE SIgNAL CONDITIONINg
ACCESSORIES AND OPTIONS DIMENSIONS
Forreferenceonly
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008822-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model GM-A Digital Display/Signal Conditioner
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Digital Display/Signal ConditionerModel GM
DESCRIPTIONThe GM is a versatile full function signal conditioner, amplifier
and power supply that works with unamplified mV/V transduc-
ers. It also provides shunt calibration (R-cal) which enables the
system to be setup without using an expensive primary stimulus
(done at no extra charge at the factory if the readout and trans-
ducer are purchased at the same time). A full range of options
like peak/hold**, track/hold and dual limits are available.
FEATURES• Strain-gage/bridge-based transducer input
• 4 1/2 digit LED display
• Large 14,2 mm [0.56 in] readout
• High speed analog output (up to 27 kHz)
*Optional 56a requires 1/4 DIN enclosure
**Bleed-off rate: <0.01 % of full scale
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Honeywell • Sensing and Control
Model GM
PHYSICAL SPECIFICATIONS
Characteristic Measure
Weight 1 kg [2.25 lb]
Mounting Bench, rack or panel (panel mount included with unit)
Case size (standard) 1/8 DIN
Case material Noryl plastic
Input/output connector Removable with screw terminals
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, storage -29 °C to 93 °C [-20 °F to 200 °F]
Temperature, operating 0 °C to 54 °C [32 °F to 130 °F]
MOUNTINg DIMENSIONS AND CHARACTERISTICS
Not RoHS compliant
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Input signal 1 mV/V to 5 mV/V or 5 mV/V to 50 mV/V (optional)
Number of characters displayed
4 1/2
Power requirements, standard
115 Vac @ 5 W
Power requirements, optional
12 Vdc, 220 Vac
Conversions per second 3
Scaling method Zero and span adjustment
Polarity indication Yes
Decimal point selection Jumper (non-solder)
Display size 14,2 mm [0.56 in]
Overrange indication Flashing display
Display resolution 1/20000 max.
Digital display LED
Analog output ±5 Vdc or 4 mA to 20 mA (optional)
Amplifier output impedance < 2 ohm
Accuracy ±0.03 %
Amplifier frequency re-sponse
dc to 250 Hz
Common mode rejection 80 db
Fine scan adjustment < ±15 %
Coarse scan adjustment > 80 %
Fine zero adjustment < ±15 %
Coarse zero adjustment > 80%
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Input range 0.5 mV/V to 5 mV/V52c. 5 mV/V to 50 mV/V
Analog output Filter setting 260 Hz58t. Optional filter setting (10 Hz, 30 Hz, 10 kHz, 27 kHz)
Alarm outputs 58a. Hi-lo limits
Display options
58c. Peak/hold58d. Track/hold
Power supply 110 Vac60a. 220 Vac60c. Battery powered (12 Vdc)56a. 4 mA to 20 mA output
Front panel 51d. Custom front panel
Mounting options 51a. Rack mount adapter51c. NEMA enclosure
TYPICAL SYSTEM DIAgRAM
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell • Sensing and Control 3
Digital Display/Signal ConditionerCOMPREHENSIVE SIgNAL CONDITIONINg
FLExIbLE PLATFORM
ACCESSORIES AND OPTIONS DIMENSIONS
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008815-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model GM Digital Display/Signal Conditioner
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]
WARNINgPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Programmable Single-Channel Transducer Indicator/Conditioner
Model SC500
DESCRIPTIONThe SC series models are self-calibrating microprocessor-
based transducer signal conditioners when used with sig mod
equipped transducers. Indicators are available with several dif-
ferent types of input channels and output channels. When used
with unamplified strain gage transducers that have the signature
calibration module installed, these instruments will completely
self calibrate zero, span, decimal point, and engineering units
automatically.
Input channels are available for a variety of transducers. Each
input channel includes an excitation power supply and either
an isolated voltage (optional) or isolated current analog output
(optional).
• Unamplifiedpressureorload
• Pressureorloadwithinternalvoltageamplifiers
• Pressureorloadwithinternalorexternaltwo-wire
current amplifiers
• ac/acdisplacementtransducer
• dc/dcdisplacementtransducer
Available output channels for the SC500 include:
• ContactrelaysforthetwoformCorthreeformAoptionallimits
• Isolateddigital-to-analogvoltage(±5Vdcor0Vdcto10Vdc)
In addition to the physical input and output channels, up to three
virtual channels can be configured to assist in many potential
applications.
FEATURES• Choiceoftransducerinputs
• Small1/8DINformfactor
• Automaticsetup,calibrationviasigcal
• Shunt-cal,mV/Vorknownloadcalibration
• Peak/valleycapture
• OptionalanalogoutputandRS-232/RS-485
• Fieldselectablefrequencyresponse(upto250Hz)and
calibration
• Uptothreevirtualchannels(optional)
• CEapproved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model SC500
PhySICAl SPECIFICATIONS
Characteristic Measure
Formfactor 1/8DIN
Case material Aluminum
ENvIRONMENTAl SPECIFICATIONS
Characteristic Measure
Temperature, operating 5°Cto40°C[40°Fto105°F]
Temperature, storage -30°Cto90°C[-40°Fto195°F]
POwER SPECIFICATIONS
Characteristic Measure
Powersupplytype ac (with included wall-mount adapter) or dc
dc power supply requirements
10Vdcto26Vdc@1A
ac wall-mount adapter (included)
Interchangeable plugs for use in the Americas, Europe, theUnitedKingdomandAustralia(100Vacto240Vac)
DISPlAy SPECIFICATIONS
Characteristic Measure
Displaytype Vacuumfluorescent
Numericdisplayformat +999999to-999999(0,1,2,3,4,5decimal places)
Digitsize,normalmode(HxW)
5mmx2,5mm[0.2inx0.1in](withengineering units)
Digitsize,largemode(HxW)
10mmx5mm[0.4inx0.2in](noengi-neering units)
Engineering units display 4characters,availableinnormalmodeonly
Displayupdatepersecond 4
lIMITS OUTPUT (OPTIONAl) SPECIFICATIONS
Characteristic Measure
Quantity 2FormCor3FormA(factoryoption)
Responsetime Same as input
Relayenergizedwhensignal is
less than, greater than, inside or outside set points
Contact ratings 1A@30Vdc,0.5A@50Vac
ANAlOg OUTPUT (OPTIONAl) SPECIFICATIONS
Characteristic Measure
Voltagerange 5Vdc,±5Vdc,10Vdcor±10Vdc(fieldselectable)
Isolation 500V
Digital-to-analogresolution 15bits
Frequencyresponse Same as input
COMMUNICATIONS OUTPUT (OPTIONAl) SPECIFICATIONS
Characteristic Measure
Serial setup and output IsolatedRS-232orRS-485(factory option)
Max. baud rate 38400Baud
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Output options
53a.RS-232(notavailablewith53d)53d.RS-485(notavailablewith53a)58a.Twolimitset-pointswithformCcontact
relays(notavailablewith58h)58h.Threelimitset-pointswithformAcontact
relays(notavailablewith58a)58i.Isolateddigital-to-analog(DAC)voltage
NotRoHScompliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
Programmable Single-Channel Transducer Indicator/Conditioner
MOUNTINg DIMENSIONS AND ChARACTERISTICS
TyPICAl SySTEM DIAgRAM
FlExIblE AND ExPANDAblE PlATFORM
Forreferenceonly
INPUT
Strain gage millivolts
high level volts/mA
ac/ac dis-placement transducer
Order code AE236 AE237 AE238
Transducer type
Unamplifiedpressure or load
Amplified pres-sureorload,dc/dc displace-ment transducer
Displacementtransducer
Range 0.5mV/Vto21mV/V
±5Vdcor±10Vdc,4mAto20mA
0.1VRMSto15VRMS
Frequency response and resolu-tion
See table below See table below See table below
Calibration type (field selectable)
Shunt,mV/V,2-,3-,or5-pointknownload
Shunt,2-,3-,or5-pointknownload
2-,3-,or5-pointknownload
Transducer excitation
5Vdc@60mAmax.
12Vdc,±15Vdc,28Vdc
3Vac@5kHz
Push button 100 % tare
Yes Yes Yes
Push button shunt test
Yes Yes No
Resolution (counts) (not including min. 10 % overrange/underrange capability)
Frequency response (hz) field selectable
Step response (ms) typi-cal
Strain gage high level ac/ac dis-placement transducer
2(fastmode)
40 ±50000 ±50000 ±25000
2 440 ±50000 ±50000 ±25000
8 110 ±25000 ±25000 ±15000
16 55 ±20000 ±25000 ±10000
32 28 ±10000 ±20000 ±10000
50 16 ±5000 ±15000 ±5000
100 8 ±5000 ±10000 ±5000
250 3 ±2000 ±10000 ±2000
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
4Honeywell•SensingandControl
Model SC500
SC500 CAPAbIlITIES
Front panel or remote tare Flexible user setup
mv/v or shunt calibration or five-point calibration Remote setup
User selectable display options Different alarm configurations (optional)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl5
Programmable Single-Channel Transducer Indicator/Conditioner
SC500 CAPAbIlITIES
User selectable filtering Math channel (optional) can act like PlC
Sig cal auto setup Analog and digital outputs (optional)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008825-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model SC500 Programmable Single-Channel Transducer Indicator/Conditioner
warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
wARNINgPERSONAl INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
wARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model NK
DESCRIPTIONThe Model NK portable instrument features a full 4 1/2 digit LCD
display and is designed for use in remote field operations as a
portable calibrator or readout device. Shunt calibration offers the
operator quick field setup with a minimum of warm-up. A peak/
hold feature is optional.
FEATURES• Strain-gage/bridge-basedtransducerinput
• 4-1/2digitLEDdisplay
• Batterypowered
• Analogoutputoption
• NotRoHScompliant
Portable LCD Display/Signal Conditioner
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model NK
GENERAL SPECIFICATIONS
Characteristic Measure
Number of channels 1
Material Deep drawn Aluminum case
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 0 °C to 54 °C [32 °F to 130 °F]
Temperature, storage -29 °C to 66 °C [-20 °F to 150 °F]
Power requirement Batteries-4“D”cells
FRONT PANEL SPECIFICATIONS
Characteristic Measure
Digital display 4-1/2 digits LCD
Environmentallysealed Weatherproof case
POWER SUPPLY SPECIFICATIONS
Characteristic Measure
Power requirements 4“D”cells
PhYSICAL ChARACTERISTICS SPECIFICATIONS
Characteristic Measure
Weight 1,4 kg [3 lb]
TRANSDUCER INTERFACE SPECIFICATIONS
Characteristic Measure
Transducer excitation 4 Vdc
Types of inputs accepted 0.5 mV/V to 4 mV/V
Transducer bridge range 350 ohm
Pushbutton shunt cal Yes
Calibration method Manual
Electricalconnectiontype PT02A-10-6S1
Zero balance ± 15 % of full scale (min.)
Noise and ripple 30 microvolts
AMPLIFIER ChARACTERISTICS SPECIFICATIONS
Characteristic Measure
Full scale outputs available 0 V to 1 V (optional)
Output impedance < 1 ohm (optional)
Non-linearity ±0.02 % of full scale (max.)
Drift, zero ±5 mV (max.)
Drift, span ±5 mV (max.)
Stability, zero 0.1 % of full scale/year
Stability, span 0.1 % of full scale/year
Frequency response 1000Hz
Span adjustment, fine ±15 % of range
Span adjustment, coarse 100 % of range
Zero adjustment, fine ±15 % of range
Zero adjustment, coarse 100 % of range
Short circuit protection Yes
DIGITAL DISPLAY ChARACTERISTICS SPECIFICATIONS
Characteristic Measure
Number of display characters
4-1/2
Conversion/second 1.5
Scaling 0-19999
Scaling method Zero and span adjustment
Max. display count 19999
Polarity indications Yes
Programmable decimal points
Yes
Display size 10,2 mm [0.4 in]
Overrange indication Yes
Resolution 1/20000
Type LCD
Max. sensitivity 0.1 microvolt/count
Peak/hold Yes (optional)
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Input 52c. 10 mV/V to 40 mV/V
Output 56e. 0 Vdc to 1 Vdc
Special features58c. Peak/hold58m. Knob zero and span adjustments
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Honeywell•SensingandControl3
Portable Display/Signal Conditioner
WIRING CODES
Wiring codes
A (+) excitation
B (+) sense
C (-) excitation
D (-) sense
E (-) input
F (+) input
MOUNTING DIMENSIONS AND ChARACTERISTICS
TYPICAL SYSTEM DIAGRAM
FEATURES
For reference only
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008824-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model NK Portable Display/Signal Conditioner
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call [email protected]
WARNINGPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Notes
1.PT06A-10-6P(SR)matingconnector,ordercodeAA119
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Model HH
DESCRIPTIONThe model HH handheld instrument features a full 3-1/2 digit
LCD display and is designed for use in remote field operations
as a portable calibrator or readout device. Shunt calibration of-
fers the operator quick field setup with a minimum of warm-up. A
peak/hold feature is standard.
FEATURES• Strain-gage/bridgebasedtransducerinput
• 31/2digitLCDdisplay
• Batterypowered
• Peakholdandshuntcalfeatures
Portable LCD Display/Signal Conditioner
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model HH
GENERAl SPECIFICATIONS
Characteristic Measure
Number of channels 1
Material Hand-held plastic case
ENVIRONMENTAl SPECIFICATIONS
Characteristic Measure
Temperature, operating 0 °C to 54 °C [32 °F to 130 °F]
Temperature, storage -29 °C to 66 °C [-20 °F to 150 °F]
Powerrequirement Battery-one9Vcell
PhySICAl ChARACTERISTICS SPECIFICATIONS
Characteristic Measure
Weight 0,5 kg [1 lb]
POwER SUPPly SPECIFICATIONS
Characteristic Measure
Powerrequirements One9Vcell
FRONT PANEl SPECIFICATIONS
Characteristic Measure
Digital display 3-1/2 digits LCD
TRANSDUCER INTERFACE SPECIFICATIONS
Characteristic Measure
Transducer excitation 2.5Vdc
Types of inputs accepted 0.5mV/Vto8mV/V
Transducer bridge 120 ohm min.
Pushbuttonshuntcal Yes
Calibration method Manual
Electrical connection type 4 banana jacks
Zero balance ±15 % of full scale (min.)
Noise and ripple 30 microvolts
AMPlIFIER ChARACTERISTICS SPECIFICATIONS
Characteristic Measure
Non-linearity ±0.1 % of full scale (max.)
Drift, zero ±50mV(max.)
Drift, span ±50mV(max.)
Stability, zero 1.0 % of full scale/year
Stability, span 1.0 % of full scale/year
Frequency response 5 Hz
Fine span adjustment ±15 % of range
Fine zero adjustment ±15 % of range
Short circuit protection Yes
DIGITAl DISPlAy ChARACTERISTICS SPECIFICATIONS
Characteristic Measure
Number of display characters
3½
Conversion/second 3
Scaling 0-1999
Scaling method Zero and span adjustment
Max. display count 1999
Polarityindications Yes
Programmabledecimalpoints
Yes
Display size 10,2 mm [0.4 in]
Overrange indication Yes
Resolution 1/2000
Type LCD
Maximum sensitivity 0.1 microvolt/count
Peak/hold Yes
OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.
Input 52c.10mV/Vto40mV/V
Not RoHS compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Sensing and Control
Automation and Control Solutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008823-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model HH Portable Display/Signal Conditioner
warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
wARNINGPERSONAl INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
wARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
MOUNTING DIMENSIONS AND ChARACTERISTICS
TyPICAl SySTEM DIAGRAM
For reference only
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Portable Strain Display Load Cell/Force Indicator
Model 7561-PSD
DESCRIPTIONThe 7561-PSD is a completely portable strain gage/bridge-based
battery-powered indicator, packaged in a small, robust IP65/
NEMA 4 enclosure. For simplified use, the operator only has ac-
cess to six keys.
Two separate ranges are available which enable the instrument
to read and display two units of measure.
The menu options offer the ability to tailor the instrument’s re-
sponse to the application. Gross, net, peak, and trough (valley)
measurements are easily selected. An annunciator indicates
which range has been selected. There is also a window, to insert
a legend, describing each range. Once these parameters are
set, it provides the user with the simplest of indicators.
FEATURES• PoweredbytwoAAinternalbatteries
• Portable,handheldprecisioninstrumentweighingonly250g
• Tactilekeyboard,withdual-rangeselection,peak/valley
hold, gross/net, and on/off controls
• Microprocessorbased,allowingsingle-passcalibration
facility
• Dualrangefacility
• Acceptsaninputrangeofupto50mV/V
• EnvironmentallysealedtoIP65/NEMA4
• 7½digitLCDdisplay,withbattery,peak,trough,net,error,
and shunt cal indication
• One-yearwarranty
• Autosleep
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model 7561-PSD
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Input type Strain gage full-bridge sensors
Input range Upto±5mV/V(±50mV/Vcanbesup-plied with factory-set option)
Nonlinearity ±0.005%FSD
Thermal drift <25ppm/°C
Excitation voltage 5Vdc(±4%),59mAmax.current
Bridge resistance, min. 85ohm(4off350ohmsensorsinparal-lel)
Internal battery Two off AA size alkaline, access via sealed rear compartment
Battery life 45hours(typ.450hoursinlowerpowermode)with350ohmsensor
Update rate Upto40ms(canbesetinconfigurationmenu)
MEChANICAl SPECIFICATIONS
Characteristic Measure
Electrical connection 5-pin Binder socket (mating plug supplied)
Physicalsize(HxWxD) 152mmx90mmx34mm[5.98inx3.5inx1.39in]
Weight 260g
Legends Insert legends for engineering unit identification (supplied)
ENvIRONMENTAl SPECIFICATIONS
Characteristic Measure
Operating temperature -10°Cto50°C[14°Fto122°F]
Environmental rating IP65 (when mating plug fitted)
INDICATION SPECIFICATIONS
Characteristic Measure
Display type 7½digitLCDdisplay,8.8mmhighdigits
Display resolution 1partin250000at1Hzupdaterate;1partin65000at10Hzupdaterate
Annunciators Lowbatterywarning:peak,trough;hold;net;shuntcal;range
CONTROl vARIAblES SPECIFICATIONS
Characteristic Measure
Front panel user keys Tactilekeyswithrecessedrimsfor:
On/off/trough Switches power on/off displays trough read.
Range Selects between two ranges
Peak Displays peak reading
Hold Switches hold on/off
Gross/net Toggles between gross/net readings
Shunt cal Putsinshuntcalmode(100Kresis.)
Settable parameters Tare/zerovalue;displayresolution/deci-malpointposition;displayupdaterate;lowpowermode;autopoweroff
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008819-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model 7561-PSD Portable Strain Display Load Cell/Force Indicator
Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]
WARNINGPERSONAl INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Strain Gage Transducer SimulatorModel TS
DESCRIPTIONThe Model TS is a strain gage transducer simulator for use in
calibration or testing display/indicators and signal conditioning
amplifiers (pressure, force, torque or weigh systems). It greatly
assists in trouble shooting, and testing of systems that use strain
gage transducers. The Model TS simulates either a 350 ohm or
5000 ohm strain gage transducer bridge with precise adjust-
ments for transducer sensitivities in five ranges in 0.5 mV/V to
10 mV/V. The output adjustments are in 10 % increments from 0
to 100 % of each of the above ranges. No batteries to replace
as the excitation voltage is supplied by the instrument to be
calibrated.
FEATURES• Easytouse
• Simulateseither350or5000ohmtransducerbridge
• Rugged,weatherproofcase
• Precisionwire-woundresistors
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2Honeywell•SensingandControl
Model TS
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating 4°Cto38°C[40°Fto100°F]
Temperature, storage -29°Cto91°C[-20°Fto195°F]
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Input excitation requirements
4.5 Vdc to 12 Vdc, constant voltage only
Input resistance 350 ohm or 5000 ohm
Fullscaleoutputranges 0.5 mV/V, 1 mV/V, 2 mV/V, 5 mV/V and 10 mV/V
Output adjustment 0 % to 100 % in 10 % steps
Output linearity and hysteresis, typical
±0.05 % of full scale
Output linearity and hysteresis, maximum
±0.10 % of full scale
Output zero balance, 350 ohm resistance
±100 microvolts max.
Output zero balance, 5000 ohm resistance
0.01 % of full scale max.
PhySICAL SPECIFICATIONS
Characteristic Measure
Connections Binding posts for use with wire or ba-nana jackets
Casesize(WxHxD) 17,8cmx12,7cmx12,7cm[7inx5inx5in]
Casematerial Aluminum
Weight 1kg[2.5lb]
MOUNTINg DIMENSIONS AND ChARACTERISTICS
TyPICAL SySTEM DIAgRAM
Forreferenceonly
NotRoHScompliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008829-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.
Model TS Strain Gage Transducer Simulator
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall honeywell be liable for consequential, special, or indirect damages.
Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com
WARNINgPERSONAL INJURy
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNINgMISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.
Failure to comply with these instructions could result in death or serious injury.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com