messtechnik_lieferprogramm_en.pdf

24
%CH 4 , %N 2 , %CO 2 , m 3 €/$ kWh/MJ SERVING THE GAS INDUSTRY WORLDWIDE RMG Messtechnik GmbH Product Range of Measuring Technology

Upload: kenangrok2009

Post on 01-Jan-2016

61 views

Category:

Documents


0 download

DESCRIPTION

meter

TRANSCRIPT

Page 1: messtechnik_lieferprogramm_en.pdf

%CH4,%N2,%CO2,…

m3

€/$

kWh/MJ

SERVING THE GAS INDUSTRY WORLDWIDE

RMG Messtechnik GmbH

Product Range of Measuring Technology

Page 2: messtechnik_lieferprogramm_en.pdf

RMG MESSTECHNIK GMBH

Overview

Within the RMG group RMG Messtechnik GmbH based in

Butzbach near Frankfurt with locations in Ebersberg near

Munich and Beindersheim in South-West Germany

produces the devices for gas measurement and covers

with it´s manufacturing program nearly all fields of gas

measurement. Most of the devices can be used for

natural gas as well as for industrial gases such as

ethylene or nitrogen. The three main categories are:

For the measurement of gas volumes or gas flow rates

different kinds of gas meters (rotary displacement

meters, turbine meters, vortex meters and ultrasonic

meters) are available, in flow rate ranges between 2.5

and 110,000 m3/h.

The choice of the computers for the determination of the

gas quantity (standard volume) and the energy contents,

the volume correctors, reaches from the compact battery

device up to the universal computer with PC technology

which can execute all current methods of calculation.

For the precise volume correction and energy calculation

gas quality values such as the superior calorific value are

required. Two devices are available for this purpose: a

correlative measuring instrument and a high-precision

gas chromatograph which provides, in addition, the

composition of natural gas.

The manufacturing program is completed by two more

product lines:

The traditional series of data loggers for meter readings,

measuring values and analysis data are complemented

with computer programs for readout and evaluation of

the registered data.

Although the gas odorization systems for the admixture

of odor substances to odorless gases like natural gas do

not belong to the measuring instruments, their

production in our factory is a long standing tradition and

the quality of these devices is not lower than that of the

measuring instruments.

The devices are available individually or as a complete

measuring system with ready-wired electrical cabinets. In

addition, we offer services like startup, recalibration and

maintenance of the devices as well as product trainings.

The other companies of the RMG group extend the range

of products by gas regulators, safety devices and a lot

more.

Gas volume metering

Volume correction

Gas quality measurement

Data storage and data analysis

Gas odorization systems

2

Page 3: messtechnik_lieferprogramm_en.pdf

CONTENTS

Controlling and monitoring of technical processes require

comprehensive experience in all fields of process

engineering.

RMG measuring systems guarantee public utilities and

industrial customers optimized accuracy. They satisfy

the most stringent quality requirements and are

permanently available

dependable

economical

easy to maintain

expandable.

We offer you tailor-made and complete solutions for all

applications in gas engineering and instrumentation.

More informations you find on our website

. There you can also download our

actual leaflets and manuals.

http://www.rmg.com

Gas measuring technology

3

Our products and services Page

Volume Meters 4

Electronic Correctors 9

Ancillary Equipment 18

Turnkey Metering Stations 20

Turbine Meters

Encoder index

Rotary Displacement Meters

Ultrasonic Flowmeter

Vortex Meters

Compact Correctors

Volume Correctors

Flow Computers

Data Logger

Counter System

Accessories for Gas Analyzers

Cabinets

Process Visualization

Miscellaneous

Data Loggers 10

Gas Analyzers 12

Data Readout / Data Evaluation 14

Gas Odorization Systems 16

Devices for Meter Readings and Analysis data

Prozess Gas Chromatograph

Gas Quality Measuring Device

Oxygen measuring device

Systems for Data Readout

Software for Data Evaluation

Gas Odorization Units

Control Units

Page 4: messtechnik_lieferprogramm_en.pdf

4

TURBINE METERS

Mechanical gas meters for custody transfer applications

Turbine Meter TRZ 03

For custody transfer applications

DIN-DVGW-tested and PTB-approved

Design according to EN 12261

LF and HF pulse transmitters in the meter head

HF pulse transmitters for turbine wheel and reference

wheel

Design also suitable for corrosive media (biogas, etc.)

100 bar

G 65 to G 16000

10 - 25000 m /h

up to 1:30 (low-pressure calibration) and up to 1:50 with

high-pressure test depending on nominal diameter and

meter size

DN 50 (2“) to DN 600 (24“), flanges up to PN 100 and

ANSI 600, horizontal or vertical gas flow

Without mechanical drive shafts in the meter head

(from DN 80 upwards)

Mechanical drive shafts in the meter head

Without meter head, only with electronic pulse

transmitter

Max. operating pressure p

Meter sizes

Measuring ranges

Connections

Type "F" - Standard

Type "F-D" - Option

Type "E" - Option

max

3

s

Turbine Meter TRZ 03-L

With perforated-plate straightener, no additional inlet

For custody transfer applications

LF and HF pulse transmitters in the meter head

HF pulse transmitters for turbine wheel

Design also suitable for corrosive media (biogas, etc.)

G 65 to G 16000

up to 1:30 (low-pressure calibration) and up to 1:50 with

high-pressure test depending on nominal diameter and

meter size

DN 50 (2“) to DN 600 (24“), flanges up to PN 100 and

ANSI 600, horizontal or vertical gas flow

Without mechanical drive shafts in the meter

(from DN 80 upwards)

Mechanical drive shafts in the meter head

pipe required

100 bar

10 - 25000 m /h

Max. operating pressure p

Measuring ranges

max

Meter sizes

Connections

Type "F" - Standard

Type "F-D" - Option

3

head

Page 5: messtechnik_lieferprogramm_en.pdf

5

TURBINE METERS

Electronic gas meters for custody transfer applications

Turbine Meter TRZ 03-TE/TEL

For custody transfer applications

LF and HF pulse transmitters in the meter head

100 bar

DIN-DVGW-tested and PTB-approved

Electronic totalizing unit (battery-operated, min. service

life 6 years)

Measurement with 2 Wiegand sensors

Digital transmission of totalizer readings is possible

Explosion protection: II 2 G EEx ib II C T 4

Flow display

Current output (external power supply unit required)

Design also suitable for corrosive media (biogas, etc.)

G 100 to G 16000

13 - 25000 m /h

up to 1:30 (low-pressure calibration) and up to 1:50 with

high-pressure test depending on nominal diameter and

meter size

DN 80 (2“) to DN 600 (24“),

flanges up to PN 100 and ANSI 600,

horizontal or vertical gas flow

Max. o pmaxperating pressure

Meter sizes

Measuring ranges

Connections

3

Transmitter unit for meter reading ENCO

For gathering and digitally transmitting original turbine

meter readings

PTB-approved

Meter reading can be adjusted digitally

Custody transfer transmission of meter readings in

accordance with the data protocol as per DSfG-AK

“Primary devices with a digital interface”

Installation on meter head of type “F”

Retrofitting

Sensor in the meter head are used to obtain the meter

readings

Flow display

Display of maximum values

Sensors in the meter head are used to obtain the meter

readings

Installation on a mechanical drive shaft

Direction of rotation of the mechanical drive shaft can

be programmed

Also for other suppliers of the turbine meter

ENCO-F

ENCO-M

Page 6: messtechnik_lieferprogramm_en.pdf

6

MECHANICAL GAS METERS

Mechanical and electronic Volumeters

Volumeter TRZ 03-K

For secondary applications

LF and HF pulse transmitters in the meter head

HF pulse transmitters for turbine wheel and reference

wheel

Design also suitable for corrosive media (biogas, etc.)

100 bar

6 - 25000 m /h

DN 50 (2“) to DN 600 (24“),

Flanges up to PN 100 and ANSI 600,

horizontal or vertical gas flow

Type "F-D" (from DN 80 upwards) with mechanical drive

shafts in the meter head

Max. operating pressure p

Measuring ranges

Connections

max

3

Standard design

Options

Flanged end for sizes from DN 50 (2“) to DN 600 (24“)

Sandwich design for sizes from DN 50 (2“) to DN 250

(10“)

Threaded-end design for sizes from DN 25 (1“) to DN

40 (1 1/2“)

Electronic Volumeter TERZ 94

For secondary applications

Electronic totalizing unit (battery-operated, min. service

life 6 years)

Explosion protection: EEx ib II C T 4

LF and HF pulse transmitters in the meter head

Design also suitable for corrosive media (biogas, etc.)

Flow display

Resettable totalizer

Current output (external power supply unit required)

Electronic suppression of the slow-down effect of a

turbine wheel after flow stop is possible

100 bar

2.5 - 25000 m /h

DN 25 (1“) to DN 600 (24“),

flanges up to PN 100 and ANSI 600,

horizontal or vertical gas flow

Flanged end for sizes from DN 50 (2“) to DN 600 (24“)

Sandwich design for sizes from DN 50 (2“) to DN 250

(10“)

Threaded-end design for sizes from DN 25 (1“) to DN

40 (1 1/2“)

Max. operating pressure p

Measuring ranges

Connections

Standard design

Options

max

3

Page 7: messtechnik_lieferprogramm_en.pdf

7

ULTRASONIC FLOWMETERS, ROTARY DISPLACEMENT METERS

Gas meters for custody transfer applications

Ultrasonic Flowmeter USZ 08

For custody transfer applications

PTB-approved

Design according to ISO 17089 and AGA 9

large measuring range up to 1:100

flanges acc. to DIN or ANSI

DZU protocol

Service interface

0/4 - 20 mA current outputs

Pulse outputs

Usable from p = 1 bar upwards

Calibration with air in conjunction with high pressure

testing acc. to TR G7

High accuracy

High stability to perturbations

6-path design

Easy to operate

High flow velocity (up to 40 m/s) results in smaller

nominal meter diameters

For use in Ex-zone 1

Sturdy and dirt-repellent sensors made of titanium

Sensor change without recalibration

100 bar (optionally 250 bar)

13 - 110000 m /h

DN 100 to DN 1000

abs

Max. operating pressure p

Measuring ranges

Connections

Interfaces

Output signals

max

3

Rotary Displacement Meters RMG 130, DKZ 04

For custody transfer applications

16 bar

Design acc. to EN 12480

Aluminium case

Setting of the totalizer depending on the direction of flow

at the measuring point without breaking seals

G 40 to G 160

0.8 - 250 m /h

DN 40 to DN 100, flanges PN 16

Spheroidal cast iron case

Meter head with integriated LF pulse transmitter

Optionally with mechanical drive shaft

G 40 to G 1000

0.65 - 1600 m /h

DN 50 to DN 200, flanges acc. to PN 10 and PN 16

For natural gas and all non-corrosive gases

Horizontal or vertical position

No inlet or outlet pipes required

Can be combined with compact volume correctors

Max. operating pressure p

RMG 132-A:

Meter sizes

Measuring ranges

Connections

DKZ 04:

Meter sizes

Measuring ranges

Connections

max

3

3

Page 8: messtechnik_lieferprogramm_en.pdf

8

VORTEX METERS

For custody transfer and secondary applications

Vortex Flowmeter WBZ 08

For custody transfer applications

DIN-DVGW-tested and PTB-approved

2-channel vortex sampling

Design also suitable for corrosive media (biogas etc.)

100 bar (higher pressures on request)

G 40 to G 25000

3 - 40000 m /h,

large measuring range up to 1:50 with high-pressure test

DN 40 to DN 600,

flanges acc. to DIN or ANSI,

Installation in any position

High overload capacity

Maintenance without shutting down the line

Unaffected by vibration and pressure shock

Max. operating pressure p

Meter sizes

Measuring ranges

Connections

A meter run for custody transfer applications consistsof an inlet pipe with a flow straightener, a vortex meterand an outlet pipe.

max

3

Vortex Flowmeter WZ 07

For secondary applications

1- or 2-channel vortex sampling

Design also suitable for corrosive media (biogas etc.)

High overload capacity

Maintenance without shutting down the line

Unaffected by vibration and pressure shock

100 bar (higher pressures on request)

1.5 - 80000 m /h,

large measuring range up to 1:60

DN 25 to DN 750,

flanges acc. to DIN or ANSI,

Installation in any position

Max. operating pressure p

Measuring ranges

Connections

max

3

Page 9: messtechnik_lieferprogramm_en.pdf

9

COMPACT CORRECTORS

Volume correctors

pTZ Volume Corrector EC 24

Volume corrector with measured values for pressure

and temperature

Calculation of the compressibility factor acc. to

GERG 88 S

PTB-approved

70 bara (for areas conforming to G 490)

LF: Reed contact with f = 1 Hz

HF: Wiegand sensor with f = 400 Hz (with direct

mounting on electronic meter)

Pressure transmitter fitted into case

Resistance thermometer: PT 1000

2 pulse outputs

Fault

0/4 - 20 mA analog output (only with external power

supply)

RS 485 (Modbus protocol)

24/DC or standard lithium batteries

-20°C bis +60°C

Suitable for use in Hazardous Zone 1

Read-out and parametrization program

Max. operating pressure p

lnput signals (volume pulses)

Transmitters

Outputs

Interface

Supply voltage

Ambient temperature range

max

max

max

Compact Volume Corrector EC 605pTZ

For calculation of the standard volume acc. to GERG 88

S or AGA-NX-19

NMI-approved

Approved for Ex-zone 1

User-programmable gas composition

Option for installation onto turbine meter or rotary

displacement meter

Data-logging feature

70 bara

Pulse output

Fault

Tamper contact

Standard lithium battery (intelligent)

Read-out and parametrization program

Reed contact with f = 4 Hz

Pressure transducer fitted into case

Resistance thermometer: PT 1000

RS 232

RS 485

Max. operating pressure p

lnput signals (volume pulses)

Outputs

Power supply

Ambient temperature range

max

max

Transmitters

Interfaces

-25°C to +60°C

Page 10: messtechnik_lieferprogramm_en.pdf

10

FLOW COMPUTERS

Volume- and density corrector , differential pressure computer

Flow Computer Series ERZ 2000

Optional use as

Beattie-Bridgeman

PTB-approved

User-programmable parameters and constants

19“ rack-mounting unit

Data-logging feature

2-channel volume input

Digital and analog inputs

Pulse and analog outputs

DSfG interface conforming to DVGW G 485

Modbus interface (ASCII / RTU / TCP)

Ethernet TCP/IP network interface

-ERZ 2004

-ERZ 2002

-ERZ 2102, ERZ 2104

-ERZ 2114

Parallel calculation of the compressibility factor acc. to

all common calculation methods such as GERG 88 S,

AGA 8, AGA NX 19 or

PC-based computer

Easy operation via internet browser

DSfG control station function

Ex-i cards for pressure, temperature and volume inputs

pluggable

230/110 V/AC, 24 V/DC

-20°C bis +55°C

Volume corrector

Density corrector

Calorific value corrector

Corrector for orifice plates

Connections

Supply voltage

Ambient temperature range

Flow Computer System EC 900

For calculation of the standard volume acc. to

GERG 88 S, AGA-NX-19 or AGA 8 Gross 1

Approval acc. to MID, EN 12495

Versions for Ex zones 1 and 2

Internal modem or external communication module

Option for installation onto turbine meter or rotary

displacement meter

Data logger with metrologically relevant logbook

40 bara (for areas conforming to G 490)

Pressure transducer fitted into case

Resistance thermometer: PT 1000, 4-wire connection

4 or 6 digital outputs (volume, alarm)

Another 4 digital outputs and 4 analog outputs

(4-20 mA) in the external communication module

115/230 VAC, 24/8.2 VDC or battery powered

-25°C to +55°C

Max. operating pressure p

lnput signals (volume pulses)

Transmitters

Outputs

Supply voltage

Ambient temperature range

max

2 x volume (reed / Wiegand / optionally NAMUR)

1 x volume (encoder)

2 or 4 status inputs

optical interface for infrared read head

RS 232/422/485

DSfG-B, Modbus ASCII / RTU

Interfaces / protocols

Page 11: messtechnik_lieferprogramm_en.pdf

11

Data Logger MRG 2203

� For custody transfer applications

PTB approval

For storage of the measured values and analysis results

from a prozess gas chromatograph (PGC) or a

correlative gas quality measuring device (KGM); for 2

devices in the versions:

- 2 PGC

- 1 PGC and 1 KGM

- 2 KGM

Master-slave-operation for 2 analysis devices

Modular construction (additional input and output cards

pluggable)

Convenient and easy to understand menu prompts

16 analog inputs

20 status message inputs

20 analog outputs

20 signal outputs

Hourly mean values for billing

Single analysis results

Hourly, daily and monthly mean values for gas

components

Calibration data with response factors (PGC) or quality

factors (KGM)

Test gas analysis results

15 minute values (calorific value, standard density,

CO ) with a memory depth of 2 years

Corrected hourly mean values (KGM only)

MRG analog values

Inputs / outputs

Archives

2

Data Logger MRG 905 / MRG 910

PTB type-approval as data logging memory and load

profile memory

Pulse, analog and message inputs

Summation with pulse output

GPRS-, GSM, ISDN, analog modem

DSfG B communication protocol

Limiting value control for quantities and analog values

Messages via SMS or e-mail

Battery and mains operation

Power supply

Case variants

Archives:

Lithium batteries

230V/AC

10-36V/DC (MRG910)

Wall-mounting enclosure

19” rack-mounting case

Measured value archive (>18 months)

Totalizer archive (>18 months)

Event archive (200 events)

Maximum value archive (25 months)

DATA LOGGERS

Data loggers for meter readings and analysis results

Page 12: messtechnik_lieferprogramm_en.pdf

12

GAS ANALYZERS

Process gas chromatographs

Process Gas Chromatograph PGC 9000 VC

High accuracy and stability

For custody transfer applications (PTB approval)

Calculation of the superior calorific value, standard

density and Wobbe index

Analysis time < 3 min

Automatic recalibration

Long-time stability thanks to a low column temperature

Very low gas consumption due to miniaturization

Low on maintenance

Consisting of measuring element, analytical computer

and periphery acc. to customers´s requirements

Carrier gas: 5.5 bar, measuring gas: 1.5 bar

-10°C to +55°C

Explosion-proof (Ex) or not explosion-proof (Non-Ex) design

Serial interfaces (RS 232 / RS 485)

Analog signals

Cabinet version for outdoor installation

Multistream design for up to 4 measuring gas inlets

Sampling probe can be extracted under pressure

Measurement of 11 natural gas components

Superior calorific value / standard density: ±0.25%

CO content: ±0.3 mol%

Accuracy

2

Operating pressure

Ambient temperature range

Explosion protection

Output signals / interfaces

Options

Process Gas Chromatograph PGC 6000

High accuracy and stability

Measurement of 11 natural gas components

PTB approval pending

Calculation of the superior calorific value, standard

density and Wobbe index

Analysis time 5 min

Automatic recalibration

Long-time stability thanks to a low column temperature

Low gas consumption due to miniaturization

Low on maintenance

Consisting of measuring element and analytical

computer with volume correction function

Superior calorific value / standard density: ±0.35%

CO content: ±0.3 mol%

Carrier gas: 4-5 bar, measuring gas: 0.5-5 bar

Serial interfaces (RS 232 / RS 485)

Analog signals

Cabinet version for outdoor installation

Periphery for sampling and pressure reduction

2

Accuracy

Operating pressure

Ambient temperature range

Explosion protection

Output signals / interfaces

-10°C to +50°C

Measuring element: EEx d

Other components (except analytical computer): EEx i

Options

Page 13: messtechnik_lieferprogramm_en.pdf

Gas Quality Measuring Device EMC 500

For custody transfer applications

Measurement of

Combustion-free, continuous measuring method

Short response time

No environmental impact (no air-conditioned room

required)

No carrier or auxiliary gas required

Calibration is made with methane

Low on maintenance

Low operating costs

Consisting of measuring element and analytical

computer

0

-20°C to +55°C

superior and inferior calorific values,standard density, Wobbe index and CO content

Operating pressure

2

Accuracy

Ambient temperature range

Explosion protection

Output signals / interfaces

Measuring ranges

±0.5% of the measured value

.3 - 2.5 bar

Explosion-proof (Ex) or not explosion-proof (Non-Ex) design

Serial interfaces (RS 232 / RS 485)

Analog signals

Superior calorific value: 8 - 16 kWh/m

Standard density: 0.65 - 1.3 kg/m

CO content: 0 - 20 mol%

n3

n3

2

13

GAS ANALYZERS

Correlative gas quality measuring device, oxygen measuring device

Oxygen M OMS 200easuring Device

Measurement of the oxygen contents of natural and

combustion gases (other gases on request)

No influence of atmospheric pressure and ambient

temperature variations, no air conditioning is required

at the place of installation

Low on maintenance

No carrier or auxiliary gas required

Simple and straightforward operation

Short response time

Low operating costs

Calibration with methane or PGC calibration gases

Long service life, no periodic exchange of wear parts

necessary

0.3 - 3.0 bar

-10°C to +55°C

Serial interfaces

Analog signals

� Consisting of measuring element and analytical

computer

±0.4% of the measured value

Explosion-proof design (EEx d)

0 - 5 mol%

Accuracy

Ambient temperature range

Explosion protection

Measuring range

Operating pressure

Output signals / interfaces

Page 14: messtechnik_lieferprogramm_en.pdf

14

DATA READOUT AND EVALUATION PROGRAMS

RDT programs, energy data evaluation

RDT Programs WICO 22

Universal data retrieval system for billing and operating

data

Fault message center with alarm

Display of instantaneous values and remote

parametrization of stations

Communication protocols:

- DSfG

- MRG

- IEC1107

Drivers of third party device manufacturers available

Communication via GSM-, GPRS-, fixed line network

modem and TCP/IP

Scalable configuration from single user to client/server

system

Different database systems

Comfortable, automated creation of station master data

Automatic schedule-controlled data retrievals

Visualization of retrieved data

Flexible data import/export in:

- ASCII

- MS Excel

- XML

- RDBMS

- GAS-X

- SAP-IS-U

Usable under:

- WinNT

- Win2000/2003

- WinXP

Evaluation Program WICAL

Energy data evaluation program

Processing of interval quantities and meter readings

from MRG and DSfG stations

Tabular and graphic evaluation of energy data

Definition of single and formula measuring points

(sums)

Standard and user-defined protocols

� Flexible data import/export in ASCII, MS Excel, XML,

RDBMS, GAS-X, SAP-IS-U

INETDATA

A service from the station planning up to the provision

of billing data

Consultating for station setup and upgrade

Device leasing, device purchase

Installation of the station technology

Data acquisition via remote readout of devices, e-mail,

file transfer (FTP)

Data preparation and distribution via internet, e-mail,

file transfer, ASCII, XML, PDF, MS Excel

Page 15: messtechnik_lieferprogramm_en.pdf

15

DATA ACQUISITION AND TRANSFER

DSfG-RDT, mobile data acquisition

DSfG-RDT for Selma

Backup of all measurement data of a DSfG bus by

digital signature

User administration and access control by X509

certificates

Communication via Ethernet with TCIP/IP, GSM, GPRS

or fixed line network modem

Safe, selective access control in the multiclient

operation (for multiline stations)

Direct data channel to the MRG 2201 or MRG 2203

with the option of parametrization via the MRG

DSfG master function

4 remote data transmission accesses

19” rack-mounting case

Entity filter (option)

Power supply230V/AC

Mobile Data Acquisition (MDA)

Device communication via IR, Bluetooth

Device types RMG/Wieser, third party manufacturers

Mobile readout devices: PDA, notebook

Road guide for the meter readers

Easy operation without computer literacy

Instructions for the meter readers

Input of measurement data (V, p, T, K)

Meter change

Low-priced standard hardware with 2 MDA programs

Reading data from MRG and saving them on

PDA/notebook

Automatic or manual presetting of the readout period

Manual input of totalizer readings (option)

Automatic synchronization (option)

Transfer of the saved MRG data from PDA to PC

Further processing via WICO 22, WICAL, MS EXCEL

Readout program MDA-Dialog

Transfer program MDA-Transfer

Page 16: messtechnik_lieferprogramm_en.pdf

16

GAS ODORIZATION UNITS

Standard desing

Gas Odorization Unit GOE 07

Odorizes according to the suction method

Flow-rate-controlled diaphragm pump

Integrated manual pump for easy filling out of the

interchangeable odorant tank

Interchangeable tank acc. to DIN 30650

Skid-mounted unit

40 bar

Odorization of up to 50000 sm /h, depending on the

odorant concentration involved

Odorization systems with a reserve pump for automatic

changeover in the event of a failure of the service

pump, with a spare tank of 5 l

Complete odorization systems (odorization unit plus

control unit fitted into a cabinet) are available on

request!

Max. back pressure p

Max. performance

Options

Special Odorization System

max

3

Delivery monitoring

Level monitoring

Stainless-steel cabinet

Floor stand

Gas Odorization Unit GOE 2000

Odorizes according to the injection method

Flow-rate-controlled diaphragm pump

Odorant is drawn from the interchangeable odorant

tank acc. to the principle of communicating vessels

80 bar

Interchangeable tank acc. to DIN 30650

Skid-mounted unit

Odorization of up to 150000 sm /h, depending on the

odorant concentration involved

Continuous odorant level measurements

Flow monitor

Odorant flow measurement

High-pressure flushing and venting device

Odorization systems with a reserve pump for automatic

changeover in the event of a failure of the service

pump, with a spare tank of 24 l

Complete odorization systems (odorization unit plus

control unit fitted into a cabinet) are available on

request!

Max. back pressure p

Max. performance

Options

Special Odorization System

max

3

Page 17: messtechnik_lieferprogramm_en.pdf

17

GAS ODORIZATION UNITS

Special designs, control units

Gas Odorization Units GOE-SO1 / GOE-SO1P

Special designs with stationary odorant tank

Odorizes according to the injection method

Flow-rate-controlled diaphragm pump

80 bar

Odorization of up to 150000 sm /h, depending on the

odorant concentration involved

Continuous odorant level measurements

Version for sulfur-free odorant

Odorant flow measurement

Overflow controller

Odorant is drawn from the odorant tank by gravity

Infinitely variable setting of the odorant concentration

Odorant tank can be filled without interrupting

operation

Odorant tanks from 200 to 1200 litres

Suitable for use with all common odorants, e.g. for THT

or mercaptans

Extension of the operating range by mounting additional

pumps

Low on maintenance

Max. back pressure p

Max. performance (with one pump)

Options

max

3

Control Unit OSG 2000

Usable for all RMG gas odorization units

Based on a stored-program controller

Modular construction

Individual adjustment is possible

Delivery and odorant level monitoring

Calculation of odorant concentration (option)

Delivery and level monitoring with alarm signalling

5 relay outputs

Internal pulse generator

Automatic changeover between internal and external

pulses

Calculation of the odorant concentration (option)

Wall-mounting case

19” rack-mounting case

Decentralized installation with operating unit and

control unit installed at different location

230V/AC

Case variants

Power supply

Page 18: messtechnik_lieferprogramm_en.pdf

Accessories for Gas Analyzers

Pressure reducing unit DRS 200�

Max. inlet pressure p : 100 bar

Standard: safety releaf valve (SBV), primary and

secondary pressure gauge, case heating, inlet filter,

restrictor,

Options: liquid separator, limit switch for secondary

pressure gauge, safety shutdown valve for measuring

gas

max

Outlet pressure: 2.5 bis 3.5 bar

In plastic case for wall or rack mounting

test port

Max. inlet pressure p : 100 bar

mounted on wall fastening panel

Standard: safety relief valve (SBV), primary and

secondary pressure gauge, inlet filter, restrictor

Options: liquid separator, limit switch for secondary

pressure gauge

For fixed installation

Max. operating pressure p : 100 bar

With shut-off valve and potential separation

Extendable under pressure

Max. operating pressure p : 100 bar

With shut-off valve and potential separation

Pressure reducing unit DRS 100

Sampling probe PES 50

Sampling probe PPS 02-R

max

max

max

18

ANCILLARY EQUIPMENT

Control unit for gas odorization units, accessories for gas analyzers

Control Unit 7 EU-4 / 7 IG-4

Control unit

Features

for gas odorization units of type GOE 07

� Built-in pulse scaler and pulse generator

Automatic or manual mode

Extendable by monitoring devices

Relay outputs for fault

Upgradeable with equipment for mounting of

- level reserve tank

- level interchangeable odorant tank

- delivery of odorization pump

19“ rack-mounting unit (7 EU-4) or wall-mounting unit

(7 IG-4)

Page 19: messtechnik_lieferprogramm_en.pdf

19

ANCILLARY EQUIPMENT

Data logger, counter system

Data Logger DS 901

Industrial PC

Features

with data logging software for storage of

the data from a process gas chromatograph

PGC 9000 VC

For process gas chromatographs with up to 4 streams

or for 4 single devices

Table and diagram display of data

Export function for data

Storage of analysis results, chromatograms and

calibration protocols

19" rack-mounting case

Connection to the printer interface of the analytical

computer

Counter System CS 905

Counter system

Features

for counting the electrical pulses

received from gas meters, with simultaneous calculation

of the volume.

Euroformat card as 19" plug-in unit

Usable as remote totalizer

Flow display

3 totalizers (

)

Option for switching off by external switching contact

Current output (0/4 - 20 mA)

main totalizer, start-stop totalizer,

resettable totalizer

LF and HF pulse outputs

Page 20: messtechnik_lieferprogramm_en.pdf

CABINETS

Subrack, cabinet and wall-mounted cabinet

Subrack

for installation of subracks and

other 19” rack-mounting units. Wall element with hinged

mounting frame and front glass door.

Subrack for installation of flow computers supply

components, explosion-proof isolating amplifiers, etc.

19“ rack-mounting unit

basic design DIN 41494

Wired and tested

Design, mounting and factory acceptance test

Delivery with detailed documentation

with power supply unit (24V/DC or 230V/AC) and fuse

card

Connection via plug and socket connections on the rear

side

Wall-mounted cabinet

Cabinets

Cabinet for installation of sub-racks and other 19” rack

mounting units

With hinged mounting frame and front glass door

Custom-made design,

Wired and tested

Complete design incl. delivery of a detailed

documentation

Factory acceptance test in presence of the customer

Alternatively with emergency power supply

20

Page 21: messtechnik_lieferprogramm_en.pdf

21

MISCELLANEOUS

Process visualization, automation, special designs, services

Process Visualization and Automation

Display of measuring values

System can be combined with a programmable

controller for automation

Generation of user-specific process displays, etc.

Design according to customer´s specifikation

Executable under a standard operating system

Integrable into existing plants

Control systems can be connected via Profibus or

Modbus

Miscellaneous

Further devices

Containers for gas analyzing equipment

Weather-proof protective cabinets

Services

Explosion-proof devices for isolation and switching

Frequency current converters

Totalizing pulse devices

Pulse comparators

Power supply units

Isolating transformers

Frequency multipliers

Bus couplers

For measuring and analytical systems

EMC 500 and PGC 9000 VC

Complete systems with measuring element, peripherals

and electronics

For explosion-protected and not explosion-protected

devices

Transportable systems, e.g. compact version of EMC

500 or installation of the analytical system in a trailer

For NDG 08, VOS 07, GOE 07 and

GOE 2000

Completely installed with additional equipment, e.g.

pressure reducer or heater

Electrical installation

Start-up, maintenance and servicing of gas measuring

systems and gas odorization units

Revision

Service

Recalibration

Product training

Page 22: messtechnik_lieferprogramm_en.pdf

22

TURNKEY STATIONS

Gas metering station, gas analysis container

Gas chromatograph PGC 9000 VC (3 stream version) with 3 gas quality

measuring devices EMC 500 as backup system

Gas analysis container, completely

equipped with process gas chromato-

graph PGC 9000 VC and electronics.

Gas metering station with two vortex

gas meters WBZ 08

6 path ultrasonic flowmeter USZ 08, in use in a gas storage

Page 23: messtechnik_lieferprogramm_en.pdf

23

QUALITY ASSURANCE

Quality control, approvals, certificates

Measuring technology and quality belong together.

Beside the normal quality control every measuring

instrument passes our testing centre and is calibrated

there before it leaves the factory. Especially for gas

meters a test facility with a flow capacity up to

25,000 m3/h is available.

Most of our devices are determined for custody transfer

applications in gas metering stations. In Germany a type-

approval of the physical-technical federal institution (PTB)

is necessary for every measuring instrument for such an

application, i.e. every device type undergoes an official

testing before the series production starts. Furthermore

approvals of many foreign authorities are on hand.

Additionally a number of regulations must be noticed in

gas technology. The most important ones are the

European pressure equipment directive 97/23/EG and

the European explosion protection directive 94/9/EG.

Also here an examination takes place by independent

institutions like DVGW or technical inspection authorities.

The compliance of the requirements of the DIN/ISO

9001 is a matter of course for us, the certification exists

since 1994.

Some important certificates which you find on our

website www.rmg.com and which we will like to send to

you if desired:

- Quality management system in compliance with EN ISO

9001

- Safety, health and environmental manage-ment system

(SCC)

- Quality assurance system for the production quality

according to the EC pressure equipment directive

- Acknowledgement of the quality assurance for the

production of equipment and protective systems

intended for use in potentially explosive atmospheres

- National acknowledgement of a testing laboratory for

measuring instruments for gas

- Operating licence for a testing laboratory for measuring

instruments for gas

Page 24: messtechnik_lieferprogramm_en.pdf

WWW.RMG.COM

RMG is your competent partner along the entire chain ran-

ging from the exploration to the supply of final consumers.

Our reliable products and systems offer to you full control

within the range of regulating and measuring technology.

Furthermore we plan and build plants according to your

requirements and offer to you reliable and modern soluti-

ons also in station automation. Ask us - we look forward to

your challenges.

CANADA

Bryan Donkin RMG Canada Ltd.

50 Clarke Street South, Woodstock

Ontario N4S 7Y5, Canada

Phone +1 519 53-98531

Fax +1 519 53-73339

USA

Mercury Instruments LLC

3940 Virginia Avenue

Cincinnati, Ohio 45227

Phone +1 513 272-1111

Fax +1 513 272-0211

RMG Messtechnik GmbH

Otto-Hahn-Straße 5

D-35510 Butzbach, Germany

Phone +49(0)6033 897-0

Fax +49(0)6033 897-130

Works Ebersberg:

Anzinger Straße 5

D-85560 Ebersberg, Germany

Phone +49(0)8092 2097-0

Fax +49(0)8092 2097-10

GERMANY

RMG Regel + Messtechnik GmbH

Osterholzstraße 45

D-34123 Kassel, Germany

Phone +49(0)561 5007-0

Fax +49(0)561 5007-107

WÄGA Wärme-Gastechnik GmbH

Osterholzstraße 45

D-34123 Kassel, Germany

Phone +49(0)561 5007-0

Fax +49(0)561 5007-207

RMG Gaselan Regel + Messtechnik GmbH

Julius-Pintsch-Ring 3

D-15517 Fürstenwalde, Germany

Phone +49(0)3361 356-60

Fax +49(0)3361 356-836

ENGLAND

Bryan Donkin RMG Gas Controls Ltd.

Enterprise Drive, Holmewood

Chesterfield S42 5UZ, England

Phone +44 (0)1246 50150-1

Fax +44 (0)1246 50150-0

POLAND

Gazomet Sp. z o.o.

ul. Sarnowska 2

63-900 Rawicz, Poland

Phone +48 (0)65 54624-01

Fax +48 (0)65 54624-08

-Software development-

Edition 10/2008We reserve the right for technical changes Manufacturing programme measuring technology

SERVING THE GAS INDUSTRY WORLDWIDE