medical image computing (cap 5937)
TRANSCRIPT
![Page 1: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/1.jpg)
MEDICAL IMAGE COMPUTING (CAP 5937)
LECTURE 4: Pre-Processing Medical Images (II)
Dr. Ulas BagciHEC 221, Center for Research in Computer Vision (CRCV), University of Central Florida (UCF), Orlando, FL [email protected] or [email protected]
1SPRING 2017
![Page 2: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/2.jpg)
Outline• Diffusion based Smoothing in Medical Scans• Intensity inhomogeneity Correction in MRI
2
![Page 3: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/3.jpg)
Linear and Non-Linear Filtering (Smoothing)
3
Linearapproach:
Treateverypixelwiththeexactsameconvolution.
Non-Linearapproach:
Treatapixelwithvaryingintensity,dependingonitsneighborhoodqualities.
![Page 4: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/4.jpg)
4
Possible?
![Page 5: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/5.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges
5
![Page 6: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/6.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges– The smoothing process is considered as diffusion
6
![Page 7: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/7.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges– The smoothing process is considered as diffusion– APPROACH: Increase the diffusivity of filter for large (homogeneous)
regions, and decrease it nearby edges!
7
![Page 8: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/8.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges– The smoothing process is considered as diffusion– APPROACH: Increase the diffusivity of filter for large (homogeneous)
regions, and decrease it nearby edges!– How can we understand homogenous and edge regions then?
8
![Page 9: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/9.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges– The smoothing process is considered as diffusion– APPROACH: Increase the diffusivity of filter for large (homogeneous)
regions, and decrease it nearby edges!– How can we understand homogenous and edge regions then?– Edge likelihood (i.e, gradient for instance) can be measured by
9
![Page 10: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/10.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges– The smoothing process is considered as diffusion– APPROACH: Increase the diffusivity of filter for large (homogeneous)
regions, and decrease it nearby edges!– How can we understand homogenous and edge regions then?– Edge likelihood (i.e, gradient for instance) can be measured by– Perona-Malik filter is based on
10
![Page 11: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/11.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges– The smoothing process is considered as diffusion– APPROACH: Increase the diffusivity of filter for large (homogeneous)
regions, and decrease it nearby edges!– How can we understand homogenous and edge regions then?– Edge likelihood (i.e, gradient for instance) can be measured by– Perona-Malik filter is based on
where it uses diffusivities such as
11
![Page 12: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/12.jpg)
Perona-Malik (Anisotropic Diffusion) Filtering
• Perona and Malik propose a nonlinear diffusion method for avoiding the blurring and localization problems of linear diffusion filtering [PAMI 1990].– Smooth the images without removing significant parts of the edges– The smoothing process is considered as diffusion– APPROACH: Increase the diffusivity of filter for large (homogeneous)
regions, and decrease it nearby edges!– How can we understand homogenous and edge regions then?– Edge likelihood (i.e, gradient for instance) can be measured by– Perona-Malik filter is based on
where it uses diffusivities such as
– approximation
12
![Page 13: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/13.jpg)
General Idea on Anisotropic Diffusivity• if (x,y)isapartofanedgeè applylittlesmoothing• Elseè applyfullsmoothing
13
![Page 14: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/14.jpg)
General Idea on Anisotropic Diffusivity• if (x,y)isapartofanedgeè applylittlesmoothing• Elseè applyfullsmoothing• Assume,Eisedgelikelihood(tellingyouifyouareinhomogeneous
oredgeregions)• CONTROLLINGTHEBLURRING(SMOOTHING)
or
14
![Page 15: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/15.jpg)
General Idea on Anisotropic Diffusivity• if (x,y)isapartofanedgeè applylittlesmoothing• Elseè applyfullsmoothing
• Definegeneralcoefficient(c)fordiffusivity:
15
![Page 16: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/16.jpg)
General Idea on Anisotropic Diffusivity• if (x,y)isapartofanedgeè applylittlesmoothing• Elseè applyfullsmoothing
• Definegeneralcoefficient(c)fordiffusivity:
16
d=1,… direction
![Page 17: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/17.jpg)
General Idea on Anisotropic Diffusivity• if (x,y)isapartofanedgeè applylittlesmoothing• Elseè applyfullsmoothing
• Definegeneralcoefficient(c)fordiffusivity:
17
Isotropic: Anisotropic:
![Page 18: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/18.jpg)
Toy Example18
Original Linearisotropicdiffusion(simpleGaussian)
![Page 19: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/19.jpg)
Toy Example19
Original Non-linearanisotropicdiffusion
![Page 20: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/20.jpg)
20
![Page 21: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/21.jpg)
21
Non-linear Diffusion
![Page 22: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/22.jpg)
Background: BrainWeb
22
WM
GM
CSF MR Brain simulator
![Page 23: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/23.jpg)
Magnetic Field Inhomogeneity23
Field inhomogeneity is measured in parts per million (ppm) with respect to the external field
Different tissues have different magnetic susceptibilities
ð distortions in magnetic field
distortions are most noticeable near air-tissue interfaces
Credit: K.Friston
![Page 24: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/24.jpg)
MR Intensity Inhomogeneity• Often hardly
noticeable, but registration, segmentation, and thus quantificationprocesses are significantly affected from inhomogeneity field
24
(credit: R.Gupta)
![Page 25: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/25.jpg)
MR Intensity Inhomogeneity
25
(credit: R.Gupta)
Large susceptibility variation in the human brain leads to greater field inhomogeneity and therefore image distortion.
![Page 26: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/26.jpg)
Intensity Inhomogeneity Correction• Problem:
– Imperfections in the RF field cause background variations in MRimages.
– Poses challenges in image segmentation and analysis.
• Goal: To develop a general method for correcting the variations that fulfills:– (R1) no need for user help per scene– (R2) no need for accurate prior segmentation
– (R3) no need for prior knowledge of tissue intensity distribution
26
![Page 27: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/27.jpg)
Intensity Inhomogeneity Correction Methods
27
Original Image Inhomogeneity Field Corrected Image
![Page 28: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/28.jpg)
Bias Correction ApproachesNumerous methods have been published in the last two decades
I. Prospective Approachesi. Phantomii. Multicoiliii. Special sequence
II. Retrospective Approachesi. Filteringii. Surface Fitting (intensity or gradient)iii. Segmentation (ML, MAP, FCM, nonparametric,…)iv. Histogram
a. High frequency maximizationb. Information amximizationc. Histogram matching
28
![Page 29: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/29.jpg)
Prospective Approaches-Phantom• Treat intensity corruption as a systematic error of the MRI
acquisition process that can either be minimized by acquiring additional images of a uniform phantom, by acquiring additional images with different coils, or by devising special imaging sequences.
29
![Page 30: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/30.jpg)
Prospective Approaches-Phantom• Treat intensity corruption as a systematic error of the MRI
acquisition process that can either be minimized by acquiring additional images of a uniform phantom, by acquiring additional images with different coils, or by devising special imaging sequences.
• Oil or water is usually used for phantoms and median filtering is applied for image smoothing.
30
![Page 31: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/31.jpg)
Prospective Approaches-Phantom• Treat intensity corruption as a systematic error of the MRI
acquisition process that can either be minimized by acquiring additional images of a uniform phantom, by acquiring additional images with different coils, or by devising special imaging sequences.
• Oil or water is usually used for phantoms and median filtering is applied for image smoothing.
• Warning: The phantom based approach cannot correct for patient-induced inhomogeneity, which is a major drawback of this approach. The remaining intensity inhomogeneity can be as high as 30%
31
![Page 32: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/32.jpg)
Prospective Approaches-MultiCoil and Special Sequences
• Volume and Surface coils– Volume coil: induce less inhomogeneity, poor SNR– Surface coil: induce severe inhomogeneity, good SNR– Method: dividing the filtered surface coil image with the body coil
image and smoothing the resulting image– Disadvantage: prolonged acquisition time
32
![Page 33: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/33.jpg)
Prospective Approaches-MultiCoil and Special Sequences
• Volume and Surface coils– Volume coil: induce less inhomogeneity, poor SNR– Surface coil: induce severe inhomogeneity, good SNR– Method: dividing the filtered surface coil image with the body coil
image and smoothing the resulting image– Disadvantage: prolonged acquisition time
• Sequence design (pulse design)– Method: the spatial distribution of the flip angle can be estimated and
used to calculate the intensity inhomogeneity. – Disadvantage: Hardware design
33
![Page 34: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/34.jpg)
Retrospective Approaches– Only a few assumptions are needed, therefore these approaches are
general.
34
![Page 35: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/35.jpg)
Retrospective Approaches– Only a few assumptions are needed, therefore these approaches are
general.– Unlike prospective approaches, these approaches can also correct
patient dependent inhomogeneities apart from scanner induced inhomogeneities.
35
![Page 36: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/36.jpg)
Retrospective Approaches– Only a few assumptions are needed, therefore these approaches are
general.– Unlike prospective approaches, these approaches can also correct
patient dependent inhomogeneities apart from scanner induced inhomogeneities.
– FILTERING:• Filtering methods assume that intensity inhomogeneity is a low-frequency
artifact that can be separated from the high-frequency signal of the imaged anatomical structures by low-pass filtering
36
![Page 37: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/37.jpg)
Retrospective Approaches– Only a few assumptions are needed, therefore these approaches are
general.– Unlike prospective approaches, these approaches can also correct
patient dependent inhomogeneities apart from scanner induced inhomogeneities.
– FILTERING:• Filtering methods assume that intensity inhomogeneity is a low-frequency
artifact that can be separated from the high-frequency signal of the imaged anatomical structures by low-pass filtering
• log v(x) is input image, CN is normalization constant, u(x) corrected image.• However, this is true only when imaged anatomical structures are
relatively small !!!
37
![Page 38: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/38.jpg)
Retrospective Approaches– Only a few assumptions are needed, therefore these approaches are
general.– Unlike prospective approaches, these approaches can also correct
patient dependent inhomogeneities apart from scanner induced inhomogeneities.
– FILTERING:• Homomorphic unsharp masking• probably the simplest and one of the most commonly used methods• b(x) (bias field) is obtained by low-pass filtering of the input image v(x),
divided by the constant CN to preserve mean or median intensity
38
![Page 39: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/39.jpg)
Prospective Approaches-Filtering/Surface Fitting
39
A representative example of a slice from a rat brain. a: Original image. b: after inhomogeneity correction with the phantom based correction algorithm. Credit: Hui et al, JMRI 2010.
![Page 40: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/40.jpg)
Retrospective Approaches– Only a few assumptions are needed, therefore these approaches are
general.– Unlike prospective approaches, these approaches can also correct
patient dependent inhomogeneities apart from scanner induced inhomogeneities.
– Segmentation-based approaches:• ML (maximum likelihood) or MAP (maximum a posteriori probability)
criterion may be used to estimate intensity distribution in MRI• FCM (fuzzy c-means) for clustering tissue classes• Connectivity criteria is used to enforce smooth labeling
40
![Page 41: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/41.jpg)
Retrospective Approaches– Only a few assumptions are needed, therefore these approaches are
general.– Unlike prospective approaches, these approaches can also correct
patient dependent inhomogeneities apart from scanner induced inhomogeneities.
– Histogram-based approaches:• directly on image intensity histograms• the inhomogeneity field is slowly varying -> it is natural to assume smooth
histogram then!• N3 method is widely used, the method is iterative and seeks the smooth
multiplicative field that maximizes the high frequency content of the distribution of tissue intensity.
41
![Page 42: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/42.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
• Consider the following model of image formation in MR:
where at location x, v is measured signal, u is true signal, n is noise. f (bias field) is unknown.
42
![Page 43: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/43.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
• Consider the following model of image formation in MR:
where at location x, v is measured signal, u is true signal, n is noise. f (bias field) is unknown.• For a noise-free case, to estimate f requires some math.
tricks such as
43
![Page 44: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/44.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
• Consider the following model of image formation in MR:
where at location x, v is measured signal, u is true signal, n is noise. f (bias field) is unknown.• For a noise-free case, to estimate f requires some math.
tricks such as
44
![Page 45: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/45.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
• Consider the following model of image formation in MR:
where at location x, v is measured signal, u is true signal, n is noise. f (bias field) is unknown.• For a noise-free case, to estimate f requires some math.
tricks such as
• Let U,V, and F be the probability densities of
45
![Page 46: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/46.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
• Consider the following model of image formation in MR:
where at location x, v is measured signal, u is true signal, n is noise. f (bias field) is unknown.• For a noise-free case, to estimate f requires some math.
tricks such as
• Let U,V, and F be the probability densities of• (approx.) if u and f are uncorrelated random variables, then
46
![Page 47: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/47.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
• Consider the following model of image formation in MR:
where at location x, v is measured signal, u is true signal, n is noise. f (bias field) is unknown.• For a noise-free case, to estimate f requires some math.
tricks such as
• Let U,V, and F be the probability densities of• (approx.) if u and f are uncorrelated random variables, then
47
if u and f are uncorrelated random variables, the distribution of their sum is found by
convolution!
![Page 48: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/48.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
1. Use log domain, and prob. densities of u,v, and f.
48
![Page 49: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/49.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
1. Use log domain, and prob. densities of u,v, and f.2. Guess a kernel f, and estimate u! (since )
49
![Page 50: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/50.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
1. Use log domain, and prob. densities of u,v, and f.2. Guess a kernel f, and estimate u! (since )3. Iterate this process until convergence
50
![Page 51: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/51.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
1. Use log domain, and prob. densities of u,v, and f.2. Guess a kernel f, and estimate u! (since )3. Iterate this process until convergence
51
The method is based on to maximize the frequency content of the image intensity distribution.
![Page 52: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/52.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
1. Use log domain, and prob. densities of u,v, and f.2. Guess a kernel f, and estimate u! (since )3. Iterate this process until convergence
How do we guess f ? (F?)
52
![Page 53: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/53.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
1. Use log domain, and prob. densities of u,v, and f.2. Guess a kernel f, and estimate u! (since )3. Iterate this process until convergence
How do we guess f ? (F?)• F is set to be Gaussian field with small variance!
53
![Page 54: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/54.jpg)
Nonparametric Non-uniform Intensity Normalization (N3-Sled, TMI 1998)
1. Use log domain, and prob. densities of u,v, and f.2. Guess a kernel f, and estimate u! (since )3. Iterate this process until convergence
How do we guess f ? (F?)• F is set to be Gaussian field with small variance!
54
The approach is simply to propose a distribution for U by sharpening the distribution V, and then to
estimate a corresponding smooth field F which produces a distribution close to the one proposed.
![Page 55: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/55.jpg)
ITK Implementation of N3• itkN3MRIBiasFieldCorrectionImageFilterTest
imageDimensioninputImageoutputImage
[shrinkFactor] [maskImage] [numberOfIterations][numberOfFittingLevels] [outputBiasField]
55
Input parameters
opt. parameters
![Page 56: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/56.jpg)
ITK Implementation of N3• itkN3MRIBiasFieldCorrectionImageFilterTest
imageDimensioninputImageoutputImage
[shrinkFactor] [maskImage] [numberOfIterations][numberOfFittingLevels] [outputBiasField]
56
Input parameters
opt. parameters
itkN3MRIBiasFieldCorrectionImageFilterTest2 t81slice.nii.gz t81corrected.nii.gz2 t81mask.nii.gz 50 4 t81biasfield.nii.gz
![Page 57: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/57.jpg)
57
(N3 based method)
![Page 58: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/58.jpg)
Local Histogram Based and Standardization Based Correction Methods
• Dividing the image into small subvolumes (via fixed thresholding for instance) in which intensity inhomogeneity was supposed to be relatively constant.
58
![Page 59: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/59.jpg)
Local Histogram Based and Standardization Based Correction Methods
• Dividing the image into small subvolumes (via fixed thresholding for instance) in which intensity inhomogeneity was supposed to be relatively constant.
• Standard intensity scale is assumed (NEXT LECTURE)– Similar intensity values are assigned to similar tissues across different
images
59
![Page 60: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/60.jpg)
Local Histogram Based and Standardization Based Correction Methods
• Dividing the image into small subvolumes (via fixed thresholding for instance) in which intensity inhomogeneity was supposed to be relatively constant.
• Standard intensity scale is assumed (NEXT LECTURE)– Similar intensity values are assigned to similar tissues across different
images• Local intensity inhomogeneity was estimated by least square
fitting of the intensity histogram model to the actual histogram of a subvolume
60
![Page 61: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/61.jpg)
Local Histogram Based and Standardization Based Correction Methods
• Dividing the image into small subvolumes (via fixed thresholding for instance) in which intensity inhomogeneity was supposed to be relatively constant.
• Standard intensity scale is assumed (NEXT LECTURE)– Similar intensity values are assigned to similar tissues across different
images• Local intensity inhomogeneity was estimated by least square
fitting of the intensity histogram model to the actual histogram of a subvolume
• The applied histogram model was a finite Gaussian mixture with seven parameters, initialized from the global histogram of the image. (B-splines are used to fit parameters)
61
![Page 62: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/62.jpg)
Better (Simpler) Method – Standardization Based Correction (SBC)
Step 0: Set Sc = S, the given scene.
Step 1: Standardize Sc to the standard intensity gray scalefor the particular imaging protocol and body regionunder consideration and output scene Ss;
Step 2: determine m tissue regions SB1, SB2, ..., SBm by usingfixed threshold intervals on Ss;
Step 3: if SBi determined in the previous iteration are notmuch (<0.1%) different from the current SBi, stop;
Step 4: else, estimate background variation in Ss as a sceneSbe, compute corrected scene Sc, and go to Step 1;
62
![Page 63: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/63.jpg)
SBC-Intuition
63
Oi Oj x
( )j xβ
( )i xβ
The existence of discontinuity between inhomogeneity maps (continuous lines) estimated independently from different tissue regions Oi and Oj.
We need a single combined inhomogeneity map for correcting the background intensity variation in the whole image.
![Page 64: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/64.jpg)
SBC-Intuition
64
1. Find a weight factor λ to minimize
2. Combine the two inhomogeneity maps β1 and β2 to obtain a new discrete inhomogeneity map βd(c): C → [0, ∞) such that, for any c∈C,
3. Determine a 2nd degree polynomial β that constitutes a LSE fit to βd .
The above steps merge O1 and O2 and are then repeated until we have only one region and a single unified inhomogeneity map.
( ) ( ) 21 2 .
c Cc cβ λβ
∈
⎡ ⎤−⎣ ⎦∑
( ) ( )( ) ( ) ( ) ( )
( ) ( ) ( )2 11 2
1 2 1 2
, ,
, , , ,d
c O c Oc c c
c O c O c O c Oδ δ
β β λβδ δ δ δ
= ++ +
![Page 65: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/65.jpg)
65
Original Corrected
![Page 66: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/66.jpg)
Standardization Based Correction (SBC) Method
66
Iteration 1 3 5 10 20
GM
WM
![Page 67: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/67.jpg)
SBC Method
67
Iteration 1 3 5 10 20The improvement in correction with increasing number of iterations. Examine the two modes corresponding to WM(large mode) and GM.
![Page 68: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/68.jpg)
SBC Method-Comparison
68
Original N3 (Sled et al.) SBC
A slice of T1-weighted brain MR image. SBC shows some improvement over N3 particularly as seen in the histogram.
![Page 69: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/69.jpg)
SBC Method-Comparison
69
Original N3 (Sled et al.) SBC
A slice of an abdominal MR image. SBC shows some improvement over N3 particularly as seen in the histogram.
![Page 70: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/70.jpg)
SBC Method-Comparison
70
Original N3 (Sled et al.) SBC
Brainweb T2-weighted MR image. SBC shows some improvement over N3 particularly as seen in the histogram.
![Page 71: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/71.jpg)
Coefficient of Variation as a quantitative evaluation metric
• CV (coefficient of variation)?
71
![Page 72: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/72.jpg)
Coefficient of Variation as a quantitative evaluation metric
• CV (coefficient of variation):
72
![Page 73: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/73.jpg)
Coefficient of Variation as a quantitative evaluation metric
• CV (coefficient of variation):
• For a given tissue class C, CV shows how much intensity inhomogeneity is introduced (existed)
73
![Page 74: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/74.jpg)
Coefficient of Variation as a quantitative evaluation metric
• CV (coefficient of variation):
• For a given tissue class C, CV shows how much intensity inhomogeneity is introduced (existed)
• There are some drawbacks in using CV!
74
![Page 75: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/75.jpg)
Coefficient of Variation as a quantitative evaluation metric
• CV (coefficient of variation):
• For a given tissue class C, CV shows how much intensity inhomogeneity is introduced (existed)
• There are some drawbacks in using CV!– Single tissue class is used C, (alternatively Coef. Of Joint Variation can
be used)
75
![Page 76: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/76.jpg)
Coefficient of Variation as a quantitative evaluation metric
• CV (coefficient of variation):
• For a given tissue class C, CV shows how much intensity inhomogeneity is introduced (existed)
• There are some drawbacks in using CV!– Single tissue class is used C, (alternatively Coef. Of Joint Variation can
be used)– Sensitive to brightness of the image (change the mean, not the std)
76
![Page 77: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/77.jpg)
Coefficient of Variation as a quantitative evaluation metric
• CV (coefficient of variation):
• For a given tissue class C, CV shows how much intensity inhomogeneity is introduced (existed)
• There are some drawbacks in using CV!– Single tissue class is used C, (alternatively Coef. Of Joint Variation can
be used)– Sensitive to brightness of the image (change the mean, not the std)– …
77
![Page 78: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/78.jpg)
SBC Method Quantitative Comparison
78
%cv (GM) %cv (WM) Set Modality Inhomo. Original N3 SBC Original N3 SBC
Normal
T1 20% 40%
11.0 13.5
9.9 10.0
9.9 9.9
6.7 9.2
5.1 5.2
5.1 5.2
T2 20% 40%
18.4 20.3
18.0 20.0
17.9 17.9
12.0 13.3
11.8 13.0
11.7 11.8
PD 20% 40%
6.3 9.7
4.6 4.6
4.5 4.5
5.5 7.5
4.7 4.6
4.7 4.6
Ms Lesions
T1 20% 40%
11.2 13.7
10.1 10.2
10.1 10.1
6.9 9.3
5.3 5.3
5.3 5.4
T2 20% 40%
10.9 13.7
10.0 10.1
9.8 9.8
8.7 10.6
8.3 8.2
8.1 8.2
PD 20% 40%
5.8 9.4
3.9 4.9
3.8 3.9
5.3 7.4
4.4 4.3
4.3 4.3
% cv of tissue intensities in segmented GM and WMregions for twelve simulated MRI scenes from Brainwebbefore and after correction by N3 SBC.
![Page 79: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/79.jpg)
SBC Method Quantitative Comparison
79
Modality % cv (GM) % cv (WM)
Original N3 SBC Original N3 SBC T2 16.7(1.61) 14.9(1.18) 14.7(1.23) 12.9(1.12) 11.5(1.07) 11.2(0.98) PD 7.1(0.32 5.9(0.20) 5.6(0.19) 7.8(0.72) 6.6(0.62) 6.2(0.51)
The mean and standard deviation of % cv of tissue intensities in segmented GM and WM regions for ten clinical T2- and PD-weighted MRI scenes of MS patients before and after correction by the N3 and SBC methods.
SBC > N3; p < 0.001.
![Page 80: MEDICAL IMAGE COMPUTING (CAP 5937)](https://reader031.vdocuments.mx/reader031/viewer/2022012511/61894fef44c17c018670de73/html5/thumbnails/80.jpg)
References and Slide Credits• Jayaram K. Udupa, MIPG of University of Pennsylvania, PA.• P. Suetens, Fundamentals of Medical Imaging, Cambridge
Univ. Press.• N. Bryan, Intro. to the science of medical imaging, Cambridge
Univ. Press.• N. Agam (toy examples)
• Next Lecture (Preprocessing of Medical Images III)– Intensity Standardization in MR Images– PET/SPECT Image Denoising (multiplicative noise)