matrix serial gauge instructions smartcraft® and nmea …

2
Matrix Serial Gauge Instructions SmartCraft® and NMEA 2000® Gauge set overview The Matrix gauge set is intended to operate on vessels using the SmartCraft® and NMEA 2000® protocols. The gauges operate on 12 volt systems and support single, dual, triple and quad engine applications. In a Matrix gauge set, the 3” Tachometer is the master and connects directly to the SmartCraft® or NMEA 2000® data bus. All other gauges are slaves and connect to the Tachometer RS-485 private bus. The Tachometer reads applicable engine pa- rameters (SmartCraft® or NMEA 2000®) and forwards them on the private bus for the slave gauges. Both the tachometer and the speedometer gauges include a LCD used to show engine parameters and conditions. The LCD has an active area of approximately 2” x 0.5” and a 128 x 32 pixel resolution. But- tons are provided underneath the LCD to select data display and acknowledge alarm conditions. LED’s are provided on either side of the LCD and are also used to indicate an alarm condition. Troubleshooting Please make sure all harness connections are fully seated and are tight. These serial gauges can only display data that they receive, if some data is blank, verify that the information is actually being sent from the engine com- puter. To properly troubleshoot NMEA 2000® or SmartCraft® CAN bus net- work, proper equipment must be used to ascertain if the engine is sending the information. Please refer to a dealer that has trained personnel of this type of engine. Some senders may need to be calibrated per manufacturers directions before they would send proper information on the CAN bus. Alarms Only the tachometer will show warning icons and red warning lights. When alarm condition occurs, pressing ENTER will acknowledge and silence the audible alarm. The active alarms and red warning lights will remain until the alarm condition is resolved. All alarms can be viewed in the Alarms window. Please refer to engine manual for more information on individual alarms. NMEA 2000® Tachometer and Speedometer Menu Structure V2.1 Eng Speed ENG DATA rpm 3500 Any number of the indicated icons in the order they occur may be displayed. Priority is given to alarms. ENG SPD ENG SPD 3500 rpm 3500rpm System Setup ALARMS Ba ery Vdc 12.5 Only appears if set to “ON” in setup UP/DWN Eng Speed ENG DATA rpm 3500 ENG DATA ENG DATA ENG DATA ENG DATA ENG DATA ENG DATA ENG DATA ENG DATA UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN Coolant Temp 80 F o Oil Press 10 psi Fuel Rate 3.5 g/h Fuel Tank 1 50 % Fuel Used 4.2 gal Trim 75 % Depth 328 Eng Hrs 0012.2 hr 1 – 4 separate screens depending on the number of fuel tanks set in setup ENTER ENTER ENG SPD ENG SPD 3500 rpm 3500rpm Depth 328 UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN Up Down Each press of the indicated key will cycle through split screen versions of all menus shown above for the le and right sides separately. ENTER See Tachometer setup menu ENTER Press/ EXIT Press/ 3 seconds then release Tachometer Main Menu Structure System Setup ENTER UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN SETUP SETUP SETUP SETUP SETUP SETUP SETUP SETUP SETUP Spd Src No GPS Contrast 5 Backlight 5 0 Units English Dept Press Enter to Clear Fuel Used Enter to Exit SETUP Spd Sec No GPS set : clearing the total fuel used is immediate without warning and irreversible. SETUP SETUP SETUP SETUP SETUP SETUP SETUP Contrast 5 Backlight 5 0 Units English Fuel Tanks 4 Dept Press Enter to Clear Fuel Used set set set set set set ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER ENTER Note “set” is displayed No GPS GPS 1 - 10 1 - 10 0 - 4 English Metric 1 - 4 On Use the Up and Down arrow keys to cycle through choices Momentary reverse video to indicate that the saved total fuel used data has been cleared global and will be broadcasted to all devices on the bus On On h h Fuel Tanks 4 ENTER Press/ EXIT Press/ 3 seconds then release Tachometer Setup Menu Structure V2.1 Depth 328 Speed Over Water 44 mph Sea Water Temp 80 F o Ba ery Volts DC 14.5 SOW SOW 44 mph 44 mph Display Setup UP/DWN UP/DWN UP/DWN UP/DWN UP/DWN This screens are permanent and have no display op ons ENTER SOW SOW 44 mph 44 mph Tank 2 75% Tank 1 50% Sea Water 80 F o SOG 35 mph Use the DWN arrow key to cycle through each of the indicated screens for the right side of the split screen DWN DWN DWN DWN DWN Use the UP arrow key to cycle through each of the indicated screens for the le side of the split screen UP See Speedometer setup menu ENTER Press/ EXIT Press/ 3 seconds then release Speedometer Main Menu Structure ENTER UP/DWN ENTER Press/ EXIT Press/ 3 seconds then release Display Setup UP/DWN UP/DWN ENTER Enter to Exit Contrast 5 Speed Units mph Dept Contrast 5 Speed Units mph Dept n ENTER ENTER ENTER 1 - 10 mph kph Kn On Note that this is independent of the global units On h h h On On Speedometer Setup Menu Structure 70180 R3 Page 1 of 2 NMEA 2000® BACKBONE 69996K 69997K 69999K 69999K OR 69998K USING NMEA 2000® SYSTEM All Minor Gauges RPM Speed ... Not Used SMARTCRAFT® JUNCTION BOX 69995K 69997K 69999K 69999K OR 69998K USING SMARTCRAFT® SYSTEM All Minor Gauges RPM Speed ... Not Used

Upload: others

Post on 21-Nov-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Matrix Serial Gauge Instructions SmartCraft® and NMEA …

Matrix Serial Gauge InstructionsSmartCraft® and NMEA 2000®

Gauge set overview The Matrix gauge set is intended to operate on vessels using the SmartCraft® and NMEA 2000® protocols. The gauges operate on 12 volt systems and support single, dual, triple and quad engine applications. In a Matrix gauge set, the 3” Tachometer is the master and connects directly to the SmartCraft® or NMEA 2000® data bus. All other gauges are slaves and connect to the Tachometer RS-485 private bus. The Tachometer reads applicable engine pa-rameters (SmartCraft® or NMEA 2000®) and forwards them on the private bus for the slave gauges. Both the tachometer and the speedometer gauges include a LCD used to show engine parameters and conditions. The LCD has an active area of approximately 2” x 0.5” and a 128 x 32 pixel resolution. But-tons are provided underneath the LCD to select data display and acknowledge alarm conditions. LED’s are provided on either side of the LCD and are also used to indicate an alarm condition.

Troubleshooting

Please make sure all harness connections are fully seated and are tight. These serial gauges can only display data that they receive, if some data is blank, verify that the information is actually being sent from the engine com-puter. To properly troubleshoot NMEA 2000® or SmartCraft® CAN bus net-work, proper equipment must be used to ascertain if the engine is sending the information. Please refer to a dealer that has trained personnel of this type of engine. Some senders may need to be calibrated per manufacturers directions before they would send proper information on the CAN bus.

Alarms

Only the tachometer will show warning icons and red warning lights. When alarm condition occurs, pressing ENTER will acknowledge and silence the audible alarm. The active alarms and red warning lights will remain until the alarm condition is resolved. All alarms can be viewed in the Alarms window. Please refer to engine manual for more information on individual alarms.

NMEA 2000® Tachometer and Speedometer Menu Structure

ENTER

V2.1

EngSpeed

ENG DATA

rpm3500

Any number of the indicated icons in the order they occur may be displayed. Priority is given to alarms.

ENG SPD ENG SPD

3500rpm 3500rpm

System Setup

ALARMS

Ba ery Vdc12.5

Only appears if set to “ON” in setup

UP/DWN

EngSpeed

ENG DATA

rpm3500

ENG DATA

ENG DATA

ENG DATA

ENG DATA ENG DATA

ENG DATA

ENG DATA

ENG DATA

UP/DWN UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

CoolantTemp 80 Fo

Oil Press 10 psi

FuelRate 3.5 g/h

FuelTank 1 50 %Fuel

Used 4.2 gal

Trim 75 % Depth 328 EngHrs 0012.2 hr

1 – 4 separate screens depending on the number of fuel tanks set in setup

ENTER

ENTER

ENG SPD ENG SPD

3500rpm 3500rpm

Depth 328

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN Up Down

Each press of the indicated key will cycle through split screen versions of all menus shown above for the le

and right sides separately.

ENTER See Tachometer setup menu

ENTER Press/ EXIT Press/ 3 seconds then release

Tachometer Main Menu Structure

System Setup ENTER

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

Spd Src No GPS

Contrast 5

Backlight 5

0

Units English

Dept

Press Enter toClear Fuel Used

Enter to Exit

SETUPSpd Sec No GPS

set

: clearing the total fuel used is immediate without warning and irreversible.

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

Contrast 5

Backlight 5

0

Units English

Fuel Tanks 4

Dept

Press Enter toClear Fuel Used

set

set

set

set

set

set

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

ENTER

Note “set” is displayed

No GPSGPS

1 - 10

1 - 10

0 - 4

EnglishMetric

1 - 4

On

Use the Up and Down

arrow

keys to

cycle

through choices

Momentary reverse video to indicate that the saved total fuel

used data has been cleared

global and will be

broadcasted to all devices on the bus

On Onhh

Fuel Tanks 4

ENTER Press/ EXIT Press/ 3 seconds then release

Tachometer Setup Menu Structure

V2.1

Depth 328

Speed Over Water 44 mph

Sea Water Temp 80 Fo

Ba ery Volts DC 14.5

SOW SOW

44 mph 44 mph

Display Setup

UP/DWN

UP/DWN

UP/DWN

UP/DWN

UP/DWN

This screens are permanent and have no display

op ons

ENTER

SOW SOW

44 mph 44 mph

Tank 275%

Tank 1

50%

Sea Water

80 Fo

SOG

35 mph

Use the DWN arrow key to cycle through each of the

indicated screens for

the right side of the split

screen

DWN

DWN

DWN

DWN

DWN

Use the UP arrow key to cycle through each of the

indicated screens for the le side of the split

screen

UP

See Speedometer setup menu

ENTER Press/ EXIT Press/ 3 seconds then release

Speedometer Main Menu Structure

ENTER

UP/DWN

ENTER Press/ EXIT Press/ 3 seconds then release

Display Setup

UP/DWN

UP/DWN

ENTER

Enter to Exit

Contrast 5

Speed Units mph

Dept

Contrast 5

Speed Units mph

Dept n

ENTER

ENTER

ENTER

1 - 10

mphkphKn

On

Note that this is independent of the global units

Onh hh OnOn

Speedometer Setup Menu Structure

70180 R3Page 1 of 2

NM

EA 2

000®

BA

CK

BO

NE

69996K 69997K 69999K 69999K

OR

69998K

USING NMEA 2000® SYSTEM

All Minor GaugesRPM Speed

...

Not Used

SMA

RTC

RA

FT®

JUN

CTI

ON

BO

X

69995K 69997K 69999K 69999K

OR

69998K

USING SMARTCRAFT® SYSTEM

All Minor GaugesRPM Speed

...

Not Used

Page 2: Matrix Serial Gauge Instructions SmartCraft® and NMEA …

Page 2 of 2

SmartCraft® Tachometer and Speedometer Menu Structure

ENTEREXIT

Press/Release ENTER button.Press/Hold ENTER button for 3 seconds then release.

Split Screens

Generic Data #1

Generic Data #2

Generic Data #3

Generic Data #4

Alarm Menu

UP

DN

UP

DN

UP

DN

UP

DN

UP

DN

UP

DN

UP

DN

UP

DN

ENTERENTER

EXITEXIT

UP

DOWN

ENTERENTER

EXITEXIT

ENTERENTER

EXITEXIT

ENTERENTER

EXITEXIT

ENTERENTER

EXITEXIT

UP

DOWN

UP

DOWN

UP

DN

UP

DN

UP

DN

UP

UP

UP

UP

DN

UP

DNUP

DN

UP

DN

ENTERENTER

EXITEXIT

UP

UP

UP

DOWN 1 of 3Coolant

Temperature

2 of 3Low Oil Pressure

3 of 3Low Battery

Voltage

SmartCraft Logo

Use the “UP” arrow key to scroll items on the left and the “DOWN” arrow key to scroll items on the right. Available screens are as follows:

Engine RPM Tank 1 Battery Voltage DC Reserved Oil LevelCoolant Temperature Tank 2 Coolant Pressure Fuel PressureEngine Oil Pressure RPM Sync. Oil Level Throttle PositionEngine Hours Trim Sync. Boost Pressure Load PercentFuel Flow Oil Temperature Trim

View list of active alarms.

by Veethree

V1.13SmartCraftNetworked

Veethree Greeting

ºF

100CoolantTemp

9999Engine Hours

psi25Oil Press

RPM3600 %75

Oil Level

125Engine Hours 9.8 g/h

Fuel Flow

Power-Up Greeting

4205 RPM

3600 3600RPMRPM

Active Alarms UP

DNUP

DNEnter To Exit

Press Enter To Exit Edit Mode

Press Enter To Exit Edit Mode

Press Enter To Exit Edit Mode

Press Enter To Exit Edit Mode

Press Enter To Exit Edit Mode

CalibrationUP

DN

UP

DN

To Generic Data #1 Screen

Contrast 5ENTERENTER

EXITEXITENTERENTER

EXITEXIT Contrast 5

ENTERENTEREXITEXIT Trim Full Down?

Yes Trim Full Up?Yes Press Enter To

Calibrate Trim

ENTERENTEREXITEXIT

AlarmDepth 5 ft

Alarm Depth 5 ft

Tilt Full Up?Yes

UP

DN

ENTERENTEREXITEXIT Press Enter To

Calibrate Tank1 Tank 1 Empty?Yes

Tank 1 50%?Yes

Tank 1 25%?Yes

Tank 1 75%?Yes

Tank 1 Full?Yes

Calibration

UP D

N

UP D

N

UP D

N

Enter To Exit

UP

DN

UP

DN

ENTERENTER

EXITEXIT Press Enter To

Calibrate Tank2 Tank 2 Empty?Yes

Tank 2 25%?Yes

Tank 2 50%?Yes

Tank 2 75%?Yes

Tank 2 Full?Yes

DN

UP

ENTERENTER

EXITEXIT Fuel Alarm Off

DN

UP

ENTERENTER

EXITEXIT

UP D

N

ENTERENTER

EXITEXIT

Paddle Speed

4.90 Hz Paddle

Speed4.90 Hz

SpeedCorrection 1.0

To Contrast Screen

DN

UP D

N

UP

DN

UP

DN

To Generic Data #1 Screen

Calibration EXITEXIT

Fuel Alarm On

SpeedCorrection

1.0

UP

D

UP

D

Tachometer Main Menu Structure

Speedometer Main Menu StructureTachometer Gauge Setup Menu Structure

Gauge Set-up

UP

DN

UP

DN

UP

DN

UP

DN

ENTERENTER

EXITEXITNumber Of Engines valid values:None, 1, 2, 3, 4 (default None)

ENTERENTER

EXITEXIT

Engine Instance valid values: (default NONE)Engine Synch Off: STBDEngine Synch Twin: STBD, PORTEngine Synch Triple: STBD, CTR, PORTEngine Synch Quad: STBD, SCTR, PCTR, PORT

UP

DN

UP

DN

ENTERENTER

EXITEXITHelm Station valid values:1, 2 (default 1)

UP

DN

UP

DN

ENTERENTER

EXITEXITAuto Scroll valid values:Yes, No (default No)

Helm 2

EngineInstance STBD

ENTERENTER

EXITEXIT

Oil Press Units valid values:kPa, Bar (default kPa)(Menu present only if Units = Metric)

UP

DN

UP

DN

ENTERENTER

EXITEXITOil Temp Sensor valid values:Yes, No (default No)

UP

DN

UP

DN

ENTERENTER

EXITEXITOil Press Sensor valid values:Yes, No (default No)

UP

DN

UP

DN

Press and hold Up and Down Arrows, for 5 seconds.

ENTERENTER Number OfEngines NONE Number Of

Engines 4

EngineInstance NONE

HelmStation 1

UP

DN

UP

DN

ENTERENTER

EXITEXITUnits valid values:US, Metric (default US)Units MetricUnits US

AutoScroll No Auto

Scroll Yes

Oil PressUnits kPa Oil Press

Units Bar

Oil PressSensor No

Oil TempSensor No Oil Temp

Sensor Yes

Oil PressSensor Yes

ENTERENTEREXITEXIT

UP D

N

UP D

N

ENTERENTEREXITEXIT

Fuel Press Sensor valid values:Yes, No (default No)

UP D

N

UP D

NENTERENTER

EXITEXITPitot Type valid values:“100 psi”, “200 psi” (default “100 psi”)

UP D

N

UP D

NTransition Speed valid values:Range 15 - 35 (default 25)

Fuel PressSensor No Fuel Press

Sensor Yes

PitotType

100 psi

PitotType

200 psi

TransitionSpeed

25 mph

TransitionSpeed

35 mph

ENTERENTEREXITEXIT

Tank 1 Type valid values:None, Fuel, Water, Waste (default Fuel)

UP D

N

UP D

N

Tank 1Type Fuel Tank 1

Type Water

ENTERENTEREXITEXIT

Tank 1 Capacity valid values:Range 0 - 999 (default 40)(Menu present only if Tank 1 Type not NoneU

P DN

UP D

N

Tank 1 Capacity40 gal

Tank 1 Capacity999 gal

ENTERENTEREXITEXIT

Tank 2 Type valid values:None, Fuel, Water, Waste (default None)

UP D

N

UP D

NENTERENTER

EXITEXIT

Tank 2 Capacity valid values:Range 0 - 999 (default 40)(Menu present only if Tank 2 Type not NoneU

PDN

UP

DN

Tank 2Type None Tank 2

Type Waste

Tank 2 Capacity40 gal

Tank 2 Capacity999 gal

ENTERENTEREnter To Exit System exits Gauge Setup and restarts

To Number Of EngineSetup Screen

UP

DN

UP

DN

EstimatedFuel Range

EXITENTER

UP

UP

DN

TripDistance

Speed

ENTEREXIT

BACKLIGHT

Press/Release ENTER button.Press/Hold ENTER button for 3 seconds then release.Press/Release UP/DOWN buttons, together.

DN

Use the “UP” arrow key to scroll items on the left and the “DOWN” arrow key to scroll items on the right.Enter button returns to Main Menu

ENTER

ENTER

EXIT

UP

DN

UP

DN

UP

DN

UP

DN

FuelManagement

SmartCraft Logo

by Veethree

V1.03SmartCraftNetworked

Veethree Greeting

Power-Up Greeting

20mphSpeed OverWater

9999 miEst. FuelRange

% 25.5 g/h

Total FuelFlow 2.3 m

galFuelEcon 33 gal

Tot FuelUsed

Exit or Return100 %25.5 g/hTotal FuelFlow

UP

DN

Exit or ReturnUP

DN

Enter To Reset100 % 0 miTripDist0 mi

TripDist

UP D

N

UP D

N

Depth 9.9Depth ftUP D

N

DisplaySetup

UP D

N

ENTER

EXIT

Adjust contrast level from 0 to 10 in increments of 1. Only values between 3 and 7 inclusive will be saved and restored at powerup. Settings beyond range will be saved as 3 or 7.

UP D

N

UP

ENTER

ENTER

kn (knots)mph (miles per hour)kph (kilometers per hour)

ENTERENTER

ENTER

Exit or Return

WaterTemperature F

o82

Sea WaterTemp

UP

DN

Display Setup Contrast 5

Speed Units mph

Contrast 5

Speed Units kph

UP

DN

To Previous PageSpeed Over Water

STEERANGLE

PRT STBSteeringAngle

UP

DN

USA Sales/SupportVeethree Electronics and Marine2050 47th Terrace EastBradenton, FL 34203 USATel 941-538-7775Fax [email protected]