masonry wall design ec 6
TRANSCRIPT
-
8/10/2019 Masonry Wall design EC 6
1/4
Jacobs Engineering
Mahape
400710 Navi Mumbai
Initials: MSM
Date: 10/22/2014
Time: 3:10 PM
Project: Worplesdon Primary School
Component: Combined wall#1
Number: B1727880
Module: Combined wall / EC6design v.7.02
Input
The calculation covers a part of a combined wall without openings.
The inner leaf is masonry and the combined wall has vertical supports.
Common dimensions for outer and inner leaf:
Height h = 2.800 m
Vertical distance between rows of wall-ties a = 300 mm
Horizontal distance in "normal" row of wall-ties banorm = 600 mm
Horizontal distance in top row of wall-ties batop = 300 mm
(along openings and the limitations of the wall an extra row of wall-ties should be inserted. Max distance: 400 mm)
Separate data for: Inner leaf Outer leaf
Thickness tI/tO = 140 mm 100 mm
Characteristic modules of elasticity E0k = 3000 MPa 3000 MPa
Vertical load LLoad = 30.0 kN/m
Topeccentricity e0 = 18 mm
Design horizontal load wI/wO = 0.20 kN/m 0.95 kN/m
(positive horizontal load is equivalent to excess pressure on the inner leaf and suction on t he outer leaf)
-
8/10/2019 Masonry Wall design EC 6
2/4
Jacobs Engineering
Mahape
400710 Navi Mumbai
Initials: MSM
Date: 10/22/2014
Time: 3:10 PM
Project: Worplesdon Primary School
Component: Combined wall#1
Number: B1727880
Module: Combined wall / EC6design v.7.02
General assumptions
Moments from wind and eccentricity in top are distributed according to the stiffness of the leafs.
The (wind)pressure in the cavity itself is assumed nil.
-
8/10/2019 Masonry Wall design EC 6
3/4
Jacobs Engineering
Mahape
400710 Navi Mumbai
Initials: MSM
Date: 10/22/2014
Time: 3:10 PM
Project: Worplesdon Primary School
Component: Combined wall#1
Number: B1727880
Module: Combined wall / EC6design v.7.02
Calculations
Results for each leaf: Inner leaf Outer leaf
Characteristic (Bending-)E-modules E0k,I/E0k,O = 1500 MPa 1500 MPa
Initial stifnessesSiI/SiO= (10 E I)/(hs) = 437.5 kN/m 159.4 kN/m
Relative st ifnesses: rI/rO = 0.73 0.27
Total horizontal load w =wI+ wO = 1.15 kN/m
Initial moment in middle M0= w h/8 + Mtop/2 = 1397 Nm/m
Corrected stiffness SkS= SiI+ SiO- LLoad = 566.9 kN/m
Deflection from moment and column effect u = 2.5 mm
(In the calculation it is presumed only support in horizontal lines)
Moments in the middle after redistribution MyI/MyO = 1078 Nm/m 393 Nm/m
Topmoments after redistribution Mtop,I/Mtop,O = 396 Nm/m 144 Nm/m
Equivalent horizontal load weqv,I/weqv,O = 0.90 kN/m 0.33 kN/m
Number of wall-tie rows n+1 = 9
Number of intervals between rows n = 8
Forces in wall-ties in t he top row BKn = 315 N/wall-tie
Forces in wall-ties in "second from the top" row BKn-1 = -176 N/wall-tie
Forces in wall-ties in a normal row BK1 = 112 N/wall-tie
Forces in wall-ties in "bottom" row BK0 = 413 N/wall-tie
-
8/10/2019 Masonry Wall design EC 6
4/4
Jacobs Engineering
Mahape
400710 Navi Mumbai
Initials: MSM
Date: 10/22/2014
Time: 3:10 PM
Project: Worplesdon Primary School
Component: Combined wall#1
Number: B1727880
Module: Combined wall / EC6design v.7.02
Result
Deflection from moment and column effect u = 2.5 mm
(In the calculation only support in horizontal lines is assumed )
The loads on t he inner leaf:
Vertical load Lload = 30.0 kN/m
Topmoment (edge moment, upper horizontal) Mtop,I = 396 Nm/m
=> Topeccentricity e0 = 13 mm
Horizontal load weqv,I = 0.90 kN/m
The loads on the outer leaf:
Topmoment Mtop,O = 144 Nm/m
Horizontal load weqv,O = 0.33 kN/m
Forces in wall-ties: tension compression
Upper row BKn = 315 N/wall-tie 0 N/wall-tie
If the upper row is the upper row of the veneer wall, the strength of anchorage should be reduced 50%
due to the reduced strength in the top courses.
"second from the top" row BKn-1 = 0 N/wall-tie 176 N/wall-tie
Normal row BK1 = 112 N/wall-tie 0 N/wall-tie
Bottom row BK0 = 413 N/wall-tie 0 N/wall-tie