masonry wall design ec 6

Upload: saifmulla

Post on 02-Jun-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/10/2019 Masonry Wall design EC 6

    1/4

    Jacobs Engineering

    Mahape

    400710 Navi Mumbai

    Initials: MSM

    Date: 10/22/2014

    Time: 3:10 PM

    Project: Worplesdon Primary School

    Component: Combined wall#1

    Number: B1727880

    Module: Combined wall / EC6design v.7.02

    Input

    The calculation covers a part of a combined wall without openings.

    The inner leaf is masonry and the combined wall has vertical supports.

    Common dimensions for outer and inner leaf:

    Height h = 2.800 m

    Vertical distance between rows of wall-ties a = 300 mm

    Horizontal distance in "normal" row of wall-ties banorm = 600 mm

    Horizontal distance in top row of wall-ties batop = 300 mm

    (along openings and the limitations of the wall an extra row of wall-ties should be inserted. Max distance: 400 mm)

    Separate data for: Inner leaf Outer leaf

    Thickness tI/tO = 140 mm 100 mm

    Characteristic modules of elasticity E0k = 3000 MPa 3000 MPa

    Vertical load LLoad = 30.0 kN/m

    Topeccentricity e0 = 18 mm

    Design horizontal load wI/wO = 0.20 kN/m 0.95 kN/m

    (positive horizontal load is equivalent to excess pressure on the inner leaf and suction on t he outer leaf)

  • 8/10/2019 Masonry Wall design EC 6

    2/4

    Jacobs Engineering

    Mahape

    400710 Navi Mumbai

    Initials: MSM

    Date: 10/22/2014

    Time: 3:10 PM

    Project: Worplesdon Primary School

    Component: Combined wall#1

    Number: B1727880

    Module: Combined wall / EC6design v.7.02

    General assumptions

    Moments from wind and eccentricity in top are distributed according to the stiffness of the leafs.

    The (wind)pressure in the cavity itself is assumed nil.

  • 8/10/2019 Masonry Wall design EC 6

    3/4

    Jacobs Engineering

    Mahape

    400710 Navi Mumbai

    Initials: MSM

    Date: 10/22/2014

    Time: 3:10 PM

    Project: Worplesdon Primary School

    Component: Combined wall#1

    Number: B1727880

    Module: Combined wall / EC6design v.7.02

    Calculations

    Results for each leaf: Inner leaf Outer leaf

    Characteristic (Bending-)E-modules E0k,I/E0k,O = 1500 MPa 1500 MPa

    Initial stifnessesSiI/SiO= (10 E I)/(hs) = 437.5 kN/m 159.4 kN/m

    Relative st ifnesses: rI/rO = 0.73 0.27

    Total horizontal load w =wI+ wO = 1.15 kN/m

    Initial moment in middle M0= w h/8 + Mtop/2 = 1397 Nm/m

    Corrected stiffness SkS= SiI+ SiO- LLoad = 566.9 kN/m

    Deflection from moment and column effect u = 2.5 mm

    (In the calculation it is presumed only support in horizontal lines)

    Moments in the middle after redistribution MyI/MyO = 1078 Nm/m 393 Nm/m

    Topmoments after redistribution Mtop,I/Mtop,O = 396 Nm/m 144 Nm/m

    Equivalent horizontal load weqv,I/weqv,O = 0.90 kN/m 0.33 kN/m

    Number of wall-tie rows n+1 = 9

    Number of intervals between rows n = 8

    Forces in wall-ties in t he top row BKn = 315 N/wall-tie

    Forces in wall-ties in "second from the top" row BKn-1 = -176 N/wall-tie

    Forces in wall-ties in a normal row BK1 = 112 N/wall-tie

    Forces in wall-ties in "bottom" row BK0 = 413 N/wall-tie

  • 8/10/2019 Masonry Wall design EC 6

    4/4

    Jacobs Engineering

    Mahape

    400710 Navi Mumbai

    Initials: MSM

    Date: 10/22/2014

    Time: 3:10 PM

    Project: Worplesdon Primary School

    Component: Combined wall#1

    Number: B1727880

    Module: Combined wall / EC6design v.7.02

    Result

    Deflection from moment and column effect u = 2.5 mm

    (In the calculation only support in horizontal lines is assumed )

    The loads on t he inner leaf:

    Vertical load Lload = 30.0 kN/m

    Topmoment (edge moment, upper horizontal) Mtop,I = 396 Nm/m

    => Topeccentricity e0 = 13 mm

    Horizontal load weqv,I = 0.90 kN/m

    The loads on the outer leaf:

    Topmoment Mtop,O = 144 Nm/m

    Horizontal load weqv,O = 0.33 kN/m

    Forces in wall-ties: tension compression

    Upper row BKn = 315 N/wall-tie 0 N/wall-tie

    If the upper row is the upper row of the veneer wall, the strength of anchorage should be reduced 50%

    due to the reduced strength in the top courses.

    "second from the top" row BKn-1 = 0 N/wall-tie 176 N/wall-tie

    Normal row BK1 = 112 N/wall-tie 0 N/wall-tie

    Bottom row BK0 = 413 N/wall-tie 0 N/wall-tie