Marco Musy Marco Musy INFN and University of Milano-Bicocca Pylos, June 2002 Aerogel as Cherenkov radiator Aerogel as Cherenkov radiator for RICH detectors for RICH detectors

Upload: rane

Post on 15-Jan-2016

34 views

Category:

Documents


0 download

DESCRIPTION

Aerogel as Cherenkov radiator for RICH detectors. Marco Musy. INFN and Universit y of Milano-Bicocca. Pylos, June 2002. The LHCb experiment. Proton-proton interactions at √ s = 14 TeV at LHC. Particle ID needed between 1-150 GeV/c. Two RICH systems with 3 Cherenkov radiators. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Marco Musy

 

Marco MusyMarco Musy

INFN and University of Milano-Bicocca

Pylos, June 2002

Aerogel as Cherenkov radiatorAerogel as Cherenkov radiator for RICH detectorsfor RICH detectors

Page 2: Marco Musy

The LHCb experimentThe LHCb experiment

Particle IDneeded between1-150 GeV/c

Proton-protonProton-proton interactions at √s = 14 TeV at LHC

Two RICHsystems with3 Cherenkovradiators

Acceptance: 10-300 mrad (bending plane)

10-250 mrad (non-bending plane)

RICH1

RICH1

RICH2

RICH2

Local Luminosity 2 x 1032 cm-2s-1

Page 3: Marco Musy

3

Momentum

LHCb RICHes detectors

LHCb RICHes detectors

RICHRICH22 RICHRICH11

m RICHRICH11

Page 4: Marco Musy

Aerogel as Cherenkov radiator

Aerogel as Cherenkov radiator

• Light, solid quartz-like structure SiO2

• Physical properties: low density, = 0.15 g/cm³ n = 1.01 ÷ 1.10,

(n = 1 + 0.20)

A = 95.88 ± 0.04, C = (6.44 ± 0.01) 10ˉ³ μm¯4 /cm A = 91.97 ± 0.05, C = (7.22 ± 0.01) 10ˉ³ μm¯4 /cmA = 88.18 ± 0.06, C = (6.95 ± 0.01) 10ˉ³ μm¯4 /cm

Novosibirsk

tile 10x10 cm²tile 7x8 cm²tile1 + tile2

Aerogel type :• Novosibirsk, Boreskov Institute of Catalysis, Russia (hygroscopic)

• SP30 Matsushita Electric works Ldt, Japan (hydrophobic) T = A e-Cd/4

A is the long transmittance

C is the clarity coefficient

8cm

Page 5: Marco Musy

Ageing tests with γAgeing tests with γ 60Co (E= 1.3 MeV, 1.7 MeV)

Dose : 420 rad/min

Page 6: Marco Musy

1 year LHCb operation

Ageing tests with protonsAgeing tests with protons

Source of radiation: Proton beam 24 GeV/cFlux : 9 109 p/cm2/s Spot size : 2 x 2 cm2

Depletion in Transmittance of ~1% after 1 year run(w.r.t. non irradiated sample taken as a reference)

13

Page 7: Marco Musy

Humidity testsHumidity testsExpose hygroscopic aerogel tile to humid air (70%)

Measure water absorption through weight

Measure Transmittance in range 200-800 nm

Loss of 30% at 300 nm Loss of 15% at 400 nm Loss of 8% at 500 nm

Page 8: Marco Musy

TestTest beam Set-up at CERNTestTest beam Set-up at CERN

Beam from CERN-PS: πˉ and p/π in the range 6 – 10 GeV/c (Δp/p = 1%)

Page 9: Marco Musy

Quantum Efficiency of the 4 photocathodes > 20% (=280-380nm)

• Bialkali photocathode, K2CsSb• Fountain shaped electric field, demagnification factor ≈ 2.3• Silicon pad sensor 2048 pixels (16 sectors x 128 pads 1x1 mm² 2.3x2.3 mm² granularity on ph.cathode)

Hybrid Photo Detectors

Hybrid Photo Detectors

AEROGEL test beam

Page 10: Marco Musy

Aerogel

Glass filter

Place holder

Rayleigh scattering Refraction on the boundaries Light absorption Light detection on photocathode Photocathode transparency...

All relevant processes are considered in the simulation:

Beam axis

photons

Geant4

Aerogel tile

Mirror

Photo Detectors

Silicon layers

Monte Carlo Monte Carlo descriptiondescriptionMonte Carlo Monte Carlo descriptiondescription

Page 11: Marco Musy

Sector #4

Sector #8

Ring region

Out of ring

sect 4

sect 8

Test beam resultsTest beam resultsTest beam resultsTest beam results• 9 Gev/c π¯ beam• 4 cm aerogel Novosibirsk• noise/pad < 2%

Page 12: Marco Musy

Photoelectron yieldPhotoelectron yieldPhotoelectron yieldPhotoelectron yield

Number of ph.electrons

Novosibirsk4 cm aerogel8 cm aerogel

On ring

• Integrate signal across the measured arcs and compare with Monte Carlo• Evaluate nr. photoelectrons: - on ring, |R-R| < 3σ - out of Cherenkov ring

Page 13: Marco Musy

Novosibirsk No filter

Filter D263

4 cm 8.3 ± 0.310.0 ± 1.1

5.6 ± 0.26.4 ± 0.7

8 cm10.7 ± 0.412.9 ± 1.1

8.4 ± 0.38.9 ± 1.0

Photoelectron yield Photoelectron yield cont’dcont’dPhotoelectron yield Photoelectron yield cont’dcont’d

Contributions to total error:• background subtraction (±1σ): ~ 5%• inefficient or noisy pads : ~ 4%• definition of ‘active region’ (±1mm): 2%• separation of on-ring/off-ring (±2mm): 3%• signal losses outside ADC thresholds (±1σ): 3%

DataMC

results are normalised to 2π acceptance

on-ring

off-ring

Npe

8 cm

4 cm

8 cm

4 cm

No filterD263

4 cm(off-ring)

1.00 ± 0.100.81 ± 0.08

0.57 ± 0.040.55 ± 0.04

8 cm(off-ring)

1.10 ± 0.101.06 ± 0.11

0.94 ± 0.070.84 ± 0.10

results are in units of 10¯²/cm²

Page 14: Marco Musy

Ring reconstructionRing reconstruction

Thickness No filter Filter D263 Glass

θc σθ θc σθ θc σθ

4 cm 250.0 5.4248.7 4.0

247.1 5.0246.8 3.0

243.6 5.3243.2 3.8

8 cm 246.8 5.8245.0 3.9

245.4 4.8243.7 3.0

246.0 5.3 --

6 cm 250.2 8.7 250.9 5.8 251.3 5.4

8 cm 249.5 9.8 250.3 6.2 --

Data

MC

Data

Novosibirsk

Matsushita

rad

• Study resolution as a function of - filter type - aerogel thickness - aerogel type

• Results per single photoelectronsingle photoelectron are (mrad):

-- Data-- Monte Carlo4cm Novosibirsk (no filter)

θc

Page 15: Marco Musy

Ring reconstruction Ring reconstruction cont’dcont’d

• Contribution to angular resolution is determined with the simulation:

• Resolution is expected to scale as A/√N + k (in the 3σ ring region)

Sourceσ (mrad)

Pixelling 1.3

Chromaticity 2.5

Point spread func.+ Emission point

1.1

Beam divergence

0.7

Allignement 2.2

TOTAL 3.8

-- Fit to data

Resolutions differ by ~20-40% in MC with respect to the Data.Still under investigation.

Page 16: Marco Musy

/p separation at

PID performancePID performance

8 GeV

8 GeV

6 GeV

10 GeV

rad

SINGLE ph.e.

6.1

4.8

3.1

θ

~30,000 events

Page 17: Marco Musy

PID performance cont’dPID performance cont’d

• Evaluate separations Nσ = Δθ/σθ, scaling with the Npe and extrapolate to the total acceptanceEnergy θp θπ Nσ

6 GeV194.0±7.8

243.6±2.9

9.3

8 GeV216.4±4.1

244.3±2.8

8.1

10 GeV224.8±3.0

242.8±2.3

6.8

π-ring

p-ring

Clear π/p separation

• For 4 cm aerogel + filter:

Page 18: Marco Musy

ConclusionConclusion The use of aerogel as Cherenkov radiator has

become reliable in high energy particle physics

Test beam has shown a photon yield which agrees with the Monte Carlo expectations

Good PID ability in the momentum range 6 – 10 GeV/c

Further studies are on the way