Page 1: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

VIDEO OUTDOOR PANELS (1 – 5 Families)for TL door phone systemsUser manual

4 wires

1 Fam. Video 2 Fam. Video

3 Fam. Video 5 Fam. Video

EN

Page 2: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

0 ContentsEN

1 Safety instructions

2 Description of the video outdoor panels

4 Recommended cables. Installation

5 Use of the video outdoor panels

1 Safety instructions

2 Description of the video outdoor panels

3 Functions of the video outdoor panels

= 12 … 14 Vd.c.+U

294 x 144 x 53 mm1,52 kg

o o- 30 C … + 60 C

VPA.1FR02Video outdoor panel

VPA.2SR02

260 x 110 x 33 mm1,3 kg

= 12 … 14 Vd.c.+U

294 x 144 x 53 mm

o o- 30 C … + 60 C

VPA.3FR02Video outdoor panel

VPA.5SR02

260 x 110 x 33 mm1,3 kg

CMOS, 1/3", 573(H) x 597(V), 800 TVL video 1 Vpp / 75 W; PAL

70º ± 25º orientable video cameraCase: aluminum + 4 mm chemically toughened glass

IR LEDs, 850 nm, IR-CUT for night vision - 10m

TOUCH keys for call and family name, backlighted during night

Access – RFID card Access – RFID card

Wall mounting height: 160 cm

1,52 kg

EN

EN

Any intervention on the installation must be performed by AUTHORIZED PERSONNEL!DO NOT power the product at 110 – 230 Va.c.!DO NOT hit the glass screen with hard objects!

If the glass screen is broken, DO NOT touch the product.Protect the products against lime and dust during renovation activities.

o70

175 cm

130 cm

115 cm

160

cm

o20

o50

6 Maintenance of the video outdoor panels

7 Warranty

EN

1

Page 3: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

3 Functions of the video outdoor panels

4 Recommended cables. Installation. The outdoor panel is mounted on the wall at a height of 1.60 m from the upper edge of the panel (see page 1). Depending on the maximum distance between the outdoor panel and the last terminal in the installation, the recommended cables are the following:

2 Option 1) 4 wires x 0.5 mm (type H03VV-F4G 0.5) for maximum 75 lm2 Option 2) 4 wires x 0.75 mm (type H05VV-F4G 0.75) for maximum 150 lm

Build features: Solid mechanical construction, built in embedded technology, with chemically toughened glass. Weatherproof, waterproof and with an operating temperature range between -30º…+ 60º C. Electronic anti-condensation system for the video camera screen. Anti-theft sensor that is activated during unauthorized unmounting from the wall. Day/night sensor for the command of TOUCH keyboard backlighting and the lighting of the IR LEDs and IR-CUT. TOUCH keyboard with the name of the resident, backlighted during night. 1/3 CMOS, 900TVL color video camera and IR LEDs for b/w image during night. Blinking red LED, signaling the presence of potential video monitoring from the panel. In-built RFID reader. Access by secured RFID tag/card. Allows the connection of a DVR, for extended monitoring and video recording from the panel.Settings/Programming Programming and deletion of RFID building access tags/cards. Programming of new address 2, 3 or 4, for parallel connected panels, in case of buildings with multiple entrances. (maximum 4 outdoor panels for one building). Enabling or disabling of video monitoring signaling (Red LED ON/OFF), through the JP1: RED LED/0. (ch. 4.1-step 4) Enabling or disabling DVR video recording (ON/OFF) through the jumper JP40: 1-2 (OFF) / 2-3(ON) (ch. 4.1)Extensions Allows the parallel connection of maximum 4 outdoor panels, through a video selection box (VSB). Allows the connection of an additional video camera directly to the central supply unit (SCU), or of 4 additional video cameras, through a video selection box (VSB).

Connections

to the VPA

outdoor panel

+U

C/D

GND

+U

C/D

GND

UTP cat5e (AWG24)

UTP cat6e (AWG23)

25-30mm6mm

VinVout

6mm25-30mm

Connections

to the SCU

central supply unit

+U

C/D

GND

Vin

+U

C/D

6mm

25-30mm

GND

Vout

6mm

25-30mm

Connections

to the SCU

central supply unit

Connections

to the VPA

outdoor panel

EN

2

*Important:

Maintain the same colors for the same connections.

Example: +U = Red, C/D = Blue, GND = Black, Vin/Vout = Green.

For electrical safety reasons, we recommend installing an earthing cable between the panel and the SCU, connected to an

earth grounding (ISO - IEC 60950-1:2005)

Option 3) UTP cat5e (AWG24) or UTP cat6e (AWG23), for maximum 250 lm The wires will be arranged as per the below table:

EN

EN

Page 4: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

o 70

4.1 Installation of the advanced Video Outdoor Panel (VPA)ST

EP 1 Mounting on the wall - Flush

Only for maximum 8 fam. video outdoor panels

Setting of image recording on DVR from the outdoor panel, with JP2: DVR

o+25o+25

o25

o25

o30

o30

EN

3

5 cm ≈20 cm ≈20 cm

1.5cm

Mount back the family name module

Signaling of video monitoring: JP1 on RED LED position

No video monitoring signaling: JP1 on 0 position

Mounting on the wall - Surface

Unmount the module and add name labels

EN

STEP

2

STEP

3

STEP

4

STEP

5

JP1

REDLED 0

o70

0JP2

DVR

DVR

JP 20

Video camera angle adjustment. (The video camera will be oriented towards the entrance door/gate!).

Page 5: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

Torx Flush

Torx

Electrical connections diagram for the advanced Video Outdoor Panel (VPA)Electrical connections in the panel

Torx

Mounting the outdoor panel on the wall

Surface

Important: For both types of mounting, the Torx screws for fastening the outdoor panels on the

wall will be very well tightened, to prevent the anti-theft alarm sensor from setting off.

+U C/D

GND

Vout +U C/

DG

ND

Vout

4.2 ENST

EP 1

STEP

1.1

EN

4

Page 6: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

+U

C/D

GND

Vin+U

C/D

GND

Vout

+U

C/D

GND

Vout

Electrical connections diagram for 1 and 2-family residences

Vcam

+U

GN

D

Vin

2

110Va.c., 50Hz, 60Hz230Va.c., 50Hz, 60Hz

SW

C 1

SW

C 2

SWC

LC 1

LC 2

LCK

AU

X 1

AU

X 2

LA

1LA

2

LS 1

LS 2

AUX,

L N

2x6Aa.c.

Fam. 1(address 1)

VPA (address 1)

GN

G 2

GN

G 1

DB

L 1

DB

L 2

Doorbell

+U

C/D

GND

Vout

+U

C/D

GND

Vout

+U

C/D

GND

Vin

+U

C/D

GND

Vin

OUT IN

Fam 1

GONG

4.3 EN

Vcam

+U

GN

D

Vin

2

110Va.c., 50Hz, 60Hz230Va.c., 50Hz, 60Hz

SW

C 1

SW

C 2

SWC

LC 1

LC 2

LCK

AU

X 1

AU

X 2

LA

1LA

2

LS 1

LS 2

AUX,

L N

2x6Aa.c.

VPA (address 1)

+U

C/D

GND

Vout

+U

C/D

GND

Vin

OUT IN

Fam 2

GN

G 2

GN

G 1

DB

L 1

DB

L 2

Doorbell GONG

Fam. 1(address 1)

+U

C/D

GND

Vin

Note2: Any type of TL terminal can be mounted indoors. For Fam. 1, the terminal has address 1, which is set by the producer. The additional terminals mounted in parallel will have the address of the main terminal For Fam. 2, the terminal will be programmed with address 2. See Ch. 6 of the user manual for TL audio-video terminals.

Note1: For residences with 1 family and one entrance (entrance 1), the outdoor panel has address 1, which is set by the producer. For multiple entrances: Entrance 2, Entrance 3, Entrance 4, panels 2, 3 and 4 will be programmed according to the procedure in Ch. 4.6.

GN

G 2

GN

G 1

DB

L 1

DB

L 2

Doorbell GONG

Fam. 2(address 2)

SCU

OU

T1

+UPROG

BAT 110/230V

OU

T2

SCU OU

T1

+UPROG

BAT 110/230V

Fam 1

EN

5

Page 7: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

Vcam

+U

GND

Vin2

11

0V

a.c.

, 50

Hz,

60

Hz

23

0V

a.c.

, 50

Hz,

60

Hz

SC

U

OUT1

+U

PRO

G

BA

T1

10

/23

0V

SWC 1SWC 2

SW

C

LC 1LC 2

LCK

AUX 1AUX 2

LA 1LA 2

LS 1LS 2

AU

X,

LN

2x

6A

a.c.

OUT3

+U

C/D

GN

D

Vin

OUT2

+U

C/D

GN

D

Vin

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

+U

C/D

GN

D

Vo

ut

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

GNG 2

GNG 1

DBL 1DBL 2

Do

orb

ell

+U

C/D

GN

D

Vin

+U

C/D

GN

D

Vin

+U

C/D

GN

DV

ou

t

+U

C/D

GN

DV

ou

t

+U

C/D

GN

DV

ou

t

Fam

. 3

(ad

dre

ss 3

)F

am. 2

(a

dd

ress

2)

Fam

. 1

(ad

dre

ss 1

)

VPA

(ad

dre

ss 1

)

OU

TIN

GO

NG

GO

NG

GO

NG

Fam

2

Fam

1

Fam

3

Not

e:

For r

esid

ence

s w

ith 3

fam

ilies

and

one

ent

ranc

e (e

ntra

nce

1),

the

outd

oor p

anel

has

add

ress

1, w

hich

is s

et b

y th

e pr

oduc

er.

For m

ultip

le e

ntra

nces

: Ent

ranc

e 2,

Ent

ranc

e 3,

Ent

ranc

e 4,

pan

els

2, 3

and

4 w

ill b

e pr

ogra

mm

ed a

ccor

ding

to th

e pr

oced

ure

in C

h. 4

.6.

Not

e:

Any

type

of T

L te

rmin

al c

an b

e m

ount

ed in

door

s.

F

or F

am. 1

, the

term

inal

has

add

ress

1, w

hich

is s

et b

y th

e pr

oduc

er.

The

add

ition

al te

rmin

als

mou

nted

in p

aral

lel w

ill h

ave

the

addr

ess

of th

e

m

ain

term

inal

F

or F

am. 2

and

Fam

. 3, t

he te

rmin

al w

ill b

e pr

ogra

mm

ed w

ith a

ddre

ss 2

,

re

spec

tivel

y ad

dres

s 3.

See

Ch.

6 o

f the

use

r man

ual f

or T

L au

dio-

vide

o

te

rmin

als.

Electrical connections diagram for 3-family residences

EN

6

4.4 EN

Page 8: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

Electrical connections diagram for 5-family residences

EN

7

Not

e:

Any

type

of T

L te

rmin

al c

an b

e m

ount

ed in

door

s..

F

or F

am. 1

, the

term

inal

has

add

ress

1, w

hich

is s

et

by

the

prod

ucer

.

T

he a

dditi

onal

term

inal

s m

ount

ed in

par

alle

l will

hav

e th

e

a

ddre

ss o

f the

mai

n te

rmin

al

Fo

r Fam

. 2, 3

, 4 a

nd 5

, the

term

inal

will

be

prog

ram

med

with

addr

ess

2, re

spec

tivel

y ad

dres

ses

3, 4

and

5. S

ee C

h. 6

of

the

user

man

ual f

or T

L au

dio-

vide

o te

rmin

als.

OU

TIN

Not

e:

For

resi

denc

es w

ith 5

fam

ilies

and

one

ent

ranc

e (e

ntra

nce

1),

the

outd

oor p

anel

has

add

ress

1, w

hich

is s

et b

y th

e pr

oduc

er.

For

mul

tiple

ent

ranc

es: E

ntra

nce

2, E

ntra

nce

3, E

ntra

nce

4,

pan

els

2, 3

and

4 w

ill b

e pr

ogra

mm

ed a

ccor

ding

to th

e

p

roce

dure

in C

h. 4

.6.

VPA

(a

dd

ress

1)

GO

NG

GO

NG

GO

NG

GO

NG

Vcam

+U

GND

Vin2

11

0V

a.c.

, 50

Hz,

60

Hz

23

0V

a.c.

, 50

Hz,

60

Hz

+U

C/D

GN

D

Vin

SC

U

OUT1

+U

PRO

G

BA

T1

10

/23

0V

SWC 1SWC 2

SW

C

LC 1LC 2

LCK

AUX 1AUX 2

LA 1LA 2

LS 1LS 2

AU

X,

LN

2x

6A

a.c.

OUT2

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

Do

orb

ell

GNG 2

GNG 1

DBL 1DBL 2

+U

C/D

GN

D

Vin

Do

orb

ell

Fam

. 4 (

add

ress

4)

GNG 2

GNG 1

DBL 1DBL 2

+U

C/D

GN

D

Vin

Do

orb

ell

GNG 2

GNG 1

DBL 1DBL 2

+U

C/D

GN

D

Vin D

oo

rbe

ll

GNG 2

GNG 1

DBL 1DBL 2

+U

C/D

GN

D

Vin

OU

T 4

OU

T 2

OU

T 3

OUT 1

+U

C/D

GN

D

Vin

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vin D

oo

rbe

ll

GNG 2

GNG 1

DBL 1DBL 2

GO

NG

OU

T

IN

VC

B

Fam

. 5 (

add

ress

5)

Fam

. 3 (

add

ress

3)

Fam

. 2 (

add

ress

2)

Fam

. 1 (

add

ress

1)

Fam

2

Fam

1

Fam

3

Fam

4

Fam

5

4.5 EN

Page 9: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

Electrical connections diagram for multiple parallel panels

(more entrances in a building)

EN

8

4.6 EN

To one ormore families

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

+U

VPA1 (address 1)

110Va.c.

230Va.c.

+U

C/D

GN

D

Vin

VPA2 (address 2)

+U

C/D

GN

D

Vin

+U

C/D

GN

D

Vin

+U

C/D

GN

D

Vin

110Va.c.

230Va.c.

110Va.c.

230Va.c.

110Va.c.

230Va.c.

OUT 1

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vin

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

+U

SCU1 SCU2 SCU3 SCU4

VSB

OUT 1 OUT 1 OUT 1

1 2 3 4

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

+U

C/D

GN

D

Vo

ut

+U

VPA3 (address 3) VPA4 (address 4)

Important: One VPA outdoor panel and one SCU central unit will be mounted at each entrance.

The VPA1 panel keeps address 1, which is set from the factory. The VPA2 panel with address 2 Long press the PROG. button at SCU 2 Long touch the Fam.1 key at the VPA2 panel. long beep Short touch the Fam.1 key, twice Two short beeps confirmation. The VPA3 panel with address 3 Long press the PROG. button at SCU 3 Long touch the Fam.1 key at the VPA3 panel. long beep Short touch the Fam.1 key, three times Three short beeps confirmation. The VPA4 panel with address 4 Long press the PROG. button at SCU 4 Long touch the Fam.1 key at the VPA4 panel. long beep Short touch the Fam.1 key, four times Four short beeps confirmation.

Note: After the beep confirmation of the new address in the panel, go to the SCU of the panel and short press the PROG. button. The programming of the address is finished.

The programming of the addresses for the panels connected in parallel is done as follows:

Fam 2

Fam 1

Fam 3

Fam 4

Fam 5

Fam 2

Fam 1

Fam 3

Fam 4

Fam 5

Fam 2

Fam 1

Fam 3

Fam 4

Fam 5

Fam 2

Fam 1

Fam 3

Fam 4

Fam 5

Page 10: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

Use of the Video Outdoor Panels

1. STAND-BY: The call keys with the name of the residents are permanently backlighted during night. The Red LED

blinks permanently.

2. CALL: Touch the key corresponding to the name of the family you are looking for. The call is acoustically signaledwith a ding-dong. Each touch of the key reinitiates the call.

4. END OF TALK: - After 1 min. from the call, if the resident does not answer. - At 10 sec. after the door/gate is opened. - Immediately, if the resident decides to end the talk without opening the door/gate.

3. TALK: If the resident answers, talk is initiated. The maximum duration of the talk is 2 min.

5. ACCESS: The door/gate will be open during the time set at the SCU (maximum 10 sec.). Access granting isacoustically signaled through a confirmation beep sequence. 6. RFID TAG/CARD ACCESS: If you program the RFID tags/cards in the outdoor panel, each resident of the building hasaccess using the secured RFID tag/card from BELLCOME. Approach the tag/card to the RFID area marked on theoutdoor panel. The access is signaled acoustically, through a confirmation beep sequence, and visually – the symbol blinks white.

EN

9

Manual programming of the RFID TAGs/CARDs in the panel

At the moment of the delivery from the factory, the TL video outdoor panels do not have access tags/cards memorized.In order to have access in the building after installation, it is mandatory to program the RFID tags/cards in theoutdoor panel. During programming the installation has to be connected to the grid (110V/230Va.c.) and fully operational.1. Go to the place where the SCU central unit of the installation is mounted. Long press (3 sec.) the PROG button on the SCU. The Red LED turns on.2. Take the RFID tags/cards to the outdoor panels. To program them, approach every tag/card for one second to the RFID area of the outdoor panel. For each programmed tag/card, the panel issues two short beeps. Repeat this step for programming all the RFID tags/cards.3. Go to the place where the SCU central unit of the installation is mounted. Short press the PROG button on the SCU. The Red LED turns off. The installation returns to normal functioning, successfully ending the programming mode.

Orientable video camera

RFID reader. RFID tag/card access

Microphone

Fastening Torx screw

IR LEDs(night lighting)

Touch keys for call,

with the name of the residents

Speaker

Fastening Torx screw1 Fam. 5 Fam.2 Fam., 3 Fam.

Fam 2

Fam 1

Fam 3

Fam 4

Fam 5

Fam 1

294

mm

274

mm

115 mm

145 mm

5 EN

Deleting the RFID access TAGs/CARDs from the panel5.2 EN

This procedure applies when you wish to give up access with RFID tags/cards. During the deletion of the RFIDtags/cards, the installation has to be connected to the grid (110V/230Va.c.) and fully operational.1. Go to the place where the SCU central unit of the installation is mounted. Long press (3 sec.) the PROG button onthe SCU. The Red LED turns on. The installation enters programming mode:

Note: The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the

name labels are added.

5.1 EN

Page 11: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

EN

10

2. To delete the RFID access tags/cards from the memory of the panel:

- Long touch the Fam. 1 key until the acoustic confirmation of the panel with a long beep.

- Short touch the Fam. 1 key 7 times. The panel issues two short confirmation beeps.

- Immediately after, long touch (2-3 sec.) the Fam. 1 key. All the codes of the RFID access tags/cards are deleted

permanently. The action is acoustically confirmed by a long beep.

3. Go to the place where the SCU central unit of the installation is mounted. Short press the PROG button on the SCU.

The Red LED turns off. The installation returns to normal functioning mode.

4. Optional: From the outdoor panel, check if the old RFID tags/cards grant access. When each RFID tag/card that has

been deleted from the memory is approached to the panel, a low frequency beep will be issued.

Adding a new RFID access TAG/CARD in the panel

This procedure applies when you wish to add new RFID access tags/cards in the outdoor panel.

1. Collect all the RFID tags/cards from all the people who have access in the building and prepare the new access

tags/cards.

2. First, follow the procedure described in chapter 5.2 for deleting all the tags/cards from the memory of the panel.

3. Follow the procedure described in chapter 5.1. In this case, when you perform point 2 of chapter 5.1, it is mandatory

to approach both the new access tags/cards, and the old tags/cards to the RFID area of the panel,

for reprogramming.

4. After performing point 3 of chapter 5.1, check if access is granted for all the programmed and reprogrammed

RFID access tags/cards.

The Touch Line audio-video terminals must be kept away from water, lime or any liquid substances, blows, fumes, powders,dust etc. For cleaning the glass screens, use a clean cloth and a special solution for glass washing. In case of renovation activities, the entire surface of the panels will be protected with plastic foil. DO NOT undo the electrical connections of the video door phone installation components. DO NOT short-circuit the electrical connections of the video door phone installation components.

a. Warranty is granted according to the current legislation in the buyer's country of residence, based on the purchase documents.b. Warranty is granted for the hidden defects of the components used in production and in case of the system not functioningaccording to the present user manual.WARRANTY IS NOT GRANTED FOR:c. Inappropriate installation and use.d. Deterioration, intentional blows.e. Unauthorized interventions to any of the components of the installationf. Theft, fire, natural disastersg. Lack of protection of the installation components in case of renovation activities.

6 Maintenance of the video outdoor panels

7 Warranty

5.3 EN

EN

EN

Page 12: Manual 4 fire nou panouri 135mm En bellcome€¦ · 0EN Contents 1Safety instructions 2Description of the video outdoor panels 4Recommended cables.Installation 5Use of the video outdoor

Designed and produced by ELECTRA Made in EU 11.2017 USM.VPA.5XR02.BLY04

ELECTRA s.r.l Bd. Chimiei nr.8,Iași - 700291 - RO www.electra.ro

ELECTRA Bischoffgasse 5/3-4, 1120 Wien - AT +43 1 810 20 99 [email protected] www.bellcome.com

Building Communications GmbH

BELLCOME is a trademark of ELECTRA Group - No. 013502646 EUIPO - Alicante, Spain

BELLCOME is a trademark of ELECTRA Group - No. 1732510 MPI - Ciudad de Mexico, Mexico

ELECTRA is a trademark of ELECTRA Group - No. 008958332 EUIPO - Alicante, Spain

BELLCOME/ELECTRA products are registered as Industrial Models at EUIPO - Alicante, Spain

The products are

CE certified.

Certificate no. E307311

ISO 9001:2008ISO 14001:2009

Certificates no. 73 100 4856, 73 104 4856

by TÜV HESSEN

The products are manufactured under

Quality and Environment Management SystemR

The products contain UL-compliant

printed circuit boards.

Certificate by R 709 ICPE Certified

by NYCE

The products are

NOM certified.