Precise Vectorial
Magnetic Sensors
Pavel Ripka
Czech Technical University, Prague
NATO ASI “Smart Sensors and MEMS”Povoa de Varzim, Portugal, 2003
![Page 2: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/2.jpg)
Magnetic Sensors: Overview
• Basics– types, specifications, principles
• Recent trends– miniaturization, high working temperature
• news in AMR and GMR magnetoresistors
• Contactless current sensors
• Applications
![Page 3: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/3.jpg)
Magnetic sensors: basic types
• Magnetic field sensors– semiconductor– ferromagnetic– other (optical, resonant, SQUID…)
• Magnetic sensors of non-magnetic variables– position, force, torque, strain– temperature
![Page 4: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/4.jpg)
Magnetic field sensors
ScalarMeasure the size of B
(“total field B”)
only resonant sensors
VectorMeasure the projection
of B into the sensitive axis• single-axis• tri-axial
most
magnetic sensors
222zyx BBBB
![Page 5: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/5.jpg)
Tri-axial sensors
Wrong waycalculate it from rms values
Many instruments use this
formula, assuming that the field
does not change direction
Right waycalculate it from
instantaneous values
How to get total field B (field magnitude)
222zyx tBtBtBtB
222rmszrmsyrmsxrms BBBB
![Page 6: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/6.jpg)
Tri-axial sensors: compass
X (forward)
Bx
Bz
By
Earth’s Field vector B
Z (down)
Y(right)
Horizontal component
= Azimuth or Heading
![Page 7: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/7.jpg)
Magnetic field sensors: DC and AC
AC
Measure only changing field:
induction coils
Vi .. Induced voltage
.. Magnetic flux
A .. Coil area
N .. Number of turns
DC
Measure DC and AC fields
most
magnetic sensors NAB
dt
d
dt
dVi
![Page 8: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/8.jpg)
Basic sensor specifications
• FS range, linearity, hysteresis• TC (“tempco”) of sensitivity• Offset, offset tempco and long-term stability• Perming (= null change after magnetic shock)
• Crossfield sensitivity• Noise
– PSD , rms or p-p value
• Resistance against environment– temperature, humidity, vibrations
![Page 9: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/9.jpg)
Types of magnetic field sensors
• Semiconductor sensors (Hall, …)• Permalloy magnetoresistors (AMR, GMR, …)• Resonant magnetometers (Proton, Cesium, ...) • SQUIDs (LTS + HTS)• Induction coils, rotating coils• Optical (Fibre optic, ... )• Fluxgate • Other principles (GMI, magnetoelastic, …)
![Page 10: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/10.jpg)
Magnetic position sensors
Analog outputLinear
– Inductive (AC)
LVDT, LCD,Inductosyn– with perm. Magnet (DC)
Angular– DC: Hall, MR– AC:
Encoders
Two-state output(active or switch):
• Induction (speed)• Inductive• Pulse wire (Wiegand)• DC (Hall or MR)
![Page 11: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/11.jpg)
Position sensors with permanent magnet
Linear (NVE)
Rotational (Sentron)
![Page 12: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/12.jpg)
Magnetic field magnitudes
100 T Pulse field
10 T Superconducting magnet
2 T Electromagnet
0.5 T Surface of strong perm. magnet (NdFeB)
0.1 T Surface of cheap magnet (ferrite)
10 mT Power cable
50 T Earth’s field
1 T Vehicle
10 fT Human brain
![Page 13: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/13.jpg)
Basic rules
Dipole field (from small objects)
B 1/r3
Long iron pipe
B 1/r2
Long straight current conductor
B 1/r
![Page 14: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/14.jpg)
Semiconductor magnetic sensors
• Hall – integrated– GaAs, Si, (Ge)
– non-plate: vertical, cylindrical
• Semiconductor magnetoresistors
• ExoticExotic(magnetotransistors, magnetodiodes,(magnetotransistors, magnetodiodes,
rotating current domain, ...)rotating current domain, ...)
![Page 15: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/15.jpg)
Hall sensors: basics
BIt
RV H
H
I t
B
VH
![Page 16: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/16.jpg)
Linear Hall sensor
Asahi Kasei Electronics: InSb Hall element (HW series)
![Page 17: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/17.jpg)
Hall integrated circuit
Analog electronics:
• Delivers constant current
• Amplifies VH
• Flips contacts
• Performs compensations
• May compare with threshold
Honeywell Hall Sensor Using Four Cross-Connected Hall Elements
![Page 18: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/18.jpg)
Programmable Hall sensor
Micronas HAL 800:
only 3 terminals
analog <> digital mode
![Page 19: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/19.jpg)
Vertical Hall sensor
I
V
J
V1
V2
V3
B
B is parallel to the substrate
Advantages:
long-term stability
robustness
Active zone is buried into a mono-crystal, far away from the chip surface.
![Page 20: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/20.jpg)
Permalloy Flux concentrators
Cylindrical Hall device with integrated magnetic flux concentrators
(Sentron AG)
Used for Hall and MR
Increase sensitivity
Possible problems:
• TC of sensitivity
• perming
• linearity
![Page 21: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/21.jpg)
Semiconductor Magnetoresistors
Siemens MR:Needle-shaped low-resistanceprecipitates of NiSb in a matrix
of InSb serve as the shorting bars.
Lorenz force deflects the electrons
electron path is longer
resistance is higher
Short and wide strips are sensitive
![Page 22: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/22.jpg)
Semiconductor MR: disadvantages
• low sensitivity for small fields
• temperature dependent
• no response to field sign
Resistance vs field for an InSb magnetoresistor at 20ºC, 0ºC, 25ºC, 60ºC, 90ºC, and 120ºC (top to
bottom).
![Page 23: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/23.jpg)
AMR: anisotropic magnetoresistance
• Permalloy thin film strip deposited on a silicon wafer magnetized in x direction
• HY rotates magnetisation M R changes by 2%-3%
HY
![Page 24: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/24.jpg)
AMR: linearisation
Bad idea:
Shifting the working point
by bias field
Good idea:
Barber-pole Al bars
deflect the current by 450
(Honeywell)
![Page 25: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/25.jpg)
AMR bridge sensor
Philips KMZ
Full bridge made of meandered resistors with barber-pole strips
![Page 26: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/26.jpg)
AMR: flipping
Unwanted change of strip
permanent magnetization may
distort the sensor characteristic.
Periodical saturation of
the permalloy strips is the cure
Characteristics of Philips KMZ 10
after positive [+] and negative [-] flip
P.F. is characteristics for periodicalflipping
+-
P.F.
![Page 27: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/27.jpg)
AMR: flipping
Flipping:
+ decreases offset+ reduces perming+ increases sensitivity
- increases power
consumption Honeywell AMR sensor
with integrated flat flipping coil
![Page 28: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/28.jpg)
GMR: Giant Magnetoresistance
Spin - dependent scaterring:
Resistance of two thin ferromagnetic layers separated by a thin nonmagnetic conducting layer can be altered by changing the moments of the ferromagnetic layers
from parallel to antiparallel.
B
I
![Page 29: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/29.jpg)
Common GMR structures
20 m
2 m 10 nm
A)C)
B)
AF Pinning Layer
Magnetic Layer
Non-magnetic Layer
A: Spin valve
B: Sandwich
C: Multilayer
technology developed
for reading heads
![Page 30: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/30.jpg)
GMR sandwich
Sensitive, but not good for linear sensors
0.7
0.705
0.71
0.715
0.72
0.725
0.73
0.735
0.74
-50 -40 -30 -20 -10 0 10 20 30 40 50applied field (Oe)
vo
ltag
e (
V)
![Page 31: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/31.jpg)
GMR: spin valve
2600
2650
2700
2750
-30 -20 -10 0 10 20 30
Applied Field (mTesla)
Res
ista
nce
(
)
8
9
10
11
12
13
-200 -100 0 100 200
Angle (Degrees)
Re
sis
tan
ce
(O
hm
s)
0
Large field response
hard layer may be demagnetized
Angular response
Unpinned soft layer rotates with external field
If saturated, responds only to field direction, not value
![Page 32: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/32.jpg)
GMR bridge sensor
GMR resistors configured as a Wheatstone bridge sensor (NVE)
• R2, R3 are shielded
• R1, R4: field is concentrated by approx. D1/D2
Still has nonlinear
response
unlike AMR bridge
(NVE) 0
50
100
150
200
250
-2.5 -1.5 -0.5 0.5 1.5 2.5
Applied Field (mTesla)
Vo
ltag
e (m
V)
0
10
20
30
40
50
Ou
tpu
t (m
V/V
)
![Page 33: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/33.jpg)
Integrated digital GMR sensor
Very sensitive:
target may be – small– weak magnet– far away
Schematic and logic output of NVE digital sensor
![Page 34: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/34.jpg)
Advantages of magnetoresistors
compared to Hall sensors:
• high sensitivity– for position sensors: magnet may be
cheaper or smaller or airgap higher– for magnetic field sensors: higher accuracy
• no piezo effect
• higher operational temperatures
![Page 35: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/35.jpg)
Fluxgate sensors
Classical fluxgates:
precise, but expensive (CTU Prague)
Most sensitive room-temperature magnetic sensors
Based on non-linear magnetization characteristics of ferromagnetic core.Measure up to 1 mTwith 100 pT resolution
![Page 36: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/36.jpg)
Fluxgate principle
• Ferromagnetic core- non-linear B-H
• Excitation and sensing coil
• Core is periodically saturated by Iexc, drops to 1twice each period
• Measured B0 causes 2nd harmonics in Vind
![Page 37: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/37.jpg)
• In absence of external field, magnetisation is symmetrical
• External measured field causes assymetry – detected in induced voltage
![Page 38: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/38.jpg)
Basic types of fluxgate
• Double core suppresses first harmonics
![Page 39: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/39.jpg)
Fluxgate magnetometer
![Page 40: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/40.jpg)
Micro-fluxgate sensors
(in development)
• flat coils• electrodeposited core or
amorphous strips• electronics on chip
• cheap• resolution still higher than
MR
Shizuoka University
![Page 41: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/41.jpg)
Contactless current sensors
NVE GMR sensor measures current in close wire
Long straight current conductor
B 1/r
![Page 42: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/42.jpg)
PCB - integrated current sensor
1 – the current lead
2 – the ferromagnetic yoke
3 – Vertical Hall sensor or MR
Sentron
![Page 43: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/43.jpg)
Current sensing: Sensor Array
Array of six sensors:
• increased sensitivity
• resistant against external currents and fields
Sentron Hall sensors with field concentrators
measure current flowing through the hole
![Page 44: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/44.jpg)
Applications: geophysics
Geometrics
cesium magnetometer
for field mapping
![Page 45: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/45.jpg)
Applications: Biomagnetism
Magnetopneumography
= mapping of the ferromagnetic dust deposited in human lungs
SQUID or fluxgate magnetometer
![Page 46: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/46.jpg)
Possible medical applications
1. Tracking devices for monitoring the 3-D position and orientation sensing potential applications in
virtual and augmented reality systems orthopaedics and biokinematics. 2. Sensor field for magnetopneumography: mapping the distribution of ferromagnetic particles in the lungs after they are magnetised by strong DC field. 2. Monitoring the position of magnetic markers,
e.g. “magnetic biscuits”
![Page 47: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/47.jpg)
Applications: Compass
Honeywell 3-axis AMR
magnetometer with digital output
X (forward)
Bx
Bz
By
Hearth
Z (down)
Y(right)
Hnorth
= Azimuth or Heading
ForwardLevel
roll
pitch
Com
pass
RightLevel
x
y
z
Magnetic compass + inclinometers
= backup for GPS
![Page 48: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/48.jpg)
Applications: Identification of Vehicles
Vehicles can be identified usig magnetic signature
The same technology is used for detection of ferromagnetic bodies
Magnetic field of Skoda carmeasured by 3-axis CTU fluxgateunder the road surface
![Page 49: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/49.jpg)
Fluxgate object locator
DIMADS
Schiebel Austria,sensors from Czech Technical
University
Applications: Security and Military
![Page 50: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/50.jpg)
Conclusions
Magnetic sensors are• contactless• robust
– vibrations, temperature, dirt
• cheap• low power
New types include• Hall: integrated, vertical• Ferromagnetic Magnetoresistors: AMR, GMR
![Page 51: Magnetic Sensors ASI Caracterizare Generala](https://reader033.vdocuments.mx/reader033/viewer/2022061120/546c42f9b4af9f40358b49bd/html5/thumbnails/51.jpg)
Resources
• www.nve.com (GMR)• www.Sentron.ch (vertical Hall)• www.ssec.honeywell.com/magnetic/ (AMR)
• www. Micronas.com (Hall)• www.Infineon.com (Siemens: Hall, GMR)• www.semiconductors.Philips.com/automotive/sensors_discretes (AMR)
• www.Geometrics.com (resonant magnetometers)• measure.feld.cvut.cz/groups/maglab (fluxgate)• Magnetic sensors and Magnetometers (book)
Artech, 2001,www.artechouse.com