CBT 2016 Aayush Patidar (Enroll User) Log Out HOME MY TEST MY PROFILE BUY PACKAGE Ask an Expert SCORE CARD TIME MANAGEMENT QUESTIONS REPORT SOLUTION Solution Report For Electrical & Electronics Measurements : Basic Level Represent whole test solution with correct and incorrect answers. View Your Test Analysis Q. No Question Status Q.1 Attempt Incorrect Your Ans. a Correct Ans. d Solution Have any doubt? FAQ? Video Solution The total current I = I 1 + I 2 in a circuit is measured as I 1 = 150 ± 1A, I 2 = 150 ± 2A, where the limits of error are given as standard deviations. I is measured as a. (300 ± 1.24) A b. (300 ± 1.73) A c. (300 ± 2) A d. (300 ± 2.24) A Q.2 Attempt Incorrect Your Ans. c Correct Ans. b Solution Have any doubt? FAQ? Video Solution Rectifier type instrument can measure a. AC only b. Both DC and AC c. DC only d. Pulsating quantities only Q.3 REPORTS NEWS

Upload: aayush-patidar

Post on 18-Feb-2016

23 views

Category:

Documents


8 download

DESCRIPTION

made easy test series

TRANSCRIPT

Page 1: Made Easy Online Test Series e&M-1

  CBT 2016 Aayush Patidar  (Enroll User) Log Out

HOME

MY TEST

MY PROFILE

BUY PACKAGE

Ask an Expert

   

SCORE CARD TIME MANAGEMENT QUESTIONS REPORT SOLUTION

Solution Report For Electrical & Electronics Measurements :Basic LevelRepresent whole test solution with correct and incorrect answers.

  View Your Test Analysis

Q.No

Question Status

Q.1

Attempt Incorrect Your Ans. a Correct Ans. dSolutionHave any doubt?FAQ?Video Solution

The total current I = I1 + I2 in a circuit is measured as I1 = 150 ± 1A, I2 =

150 ± 2A, where the limits of error are given as standard deviations. I ismeasured as

a.  (300 ± 1.24) Ab.  (300 ± 1.73) Ac.  (300 ± 2) A

d.  (300 ± 2.24) A

Q.2

Attempt Incorrect Your Ans. c Correct Ans. bSolutionHave any doubt?FAQ?Video Solution

Rectifier type instrument can measure

a.  AC only

b.  Both DC and AC

c.  DC onlyd.  Pulsating quantities only

Q.3

 

REPORTS

NEWS

 

Page 2: Made Easy Online Test Series e&M-1

Attempt Correct Correct Ans. bSolutionHave any doubt?FAQ?Video Solution

A PMMC instrument produces a deflection of 90° when a current of 2 mApasses through its moving coil. The instrument is spring controlled. Now,the instrument is redesigned with its spring constant as before and itspermanent  magnet  is  replaced  with  a  new  permanent  magnet  whichproduces twice the flux density as before. What would be the deflection,if a current of 1 mA is passed through the coil? The other features of thePMMC instrument remain the same

a.  180°

b.  90°c.  45°d.  135°

Q.4

Attempt Incorrect Your Ans. a Correct Ans. dSolutionHave any doubt?FAQ?Video Solution

A Wien bridge is used to measure the frequency of an input signal. Thesignal is : 5 sin 400πt + 0.75 sin 1200 πt (t in sec). The signal has 15% of

3rd harmonics. With this signal balance will

a.  lead to null indication and setting corresponds to 400 Hzb.  lead to null indication and setting corresponds to 1200 Hzc.  lead to null indication and setting corresponds to 600 Hz

d.  not lead to null indication

Q.5

Not Attempt Correct Ans. aSolutionHave any doubt?FAQ?Video Solution

An electrodynometer wattmeter measures power in a 1φ circuit. Loadvoltage  is  230 V and current  is  5 A at  a  lagging p.f.  of  0.1. Wattmeterpotential coil circuit resistance is 10 kΩ and inductance is 100 mH. Thepercentage error in the measurement in power will be (f = 50 Hz)

a.  3.13 %b.  3.70 %c.  4 %d.  2.5 %

Q.6

The  ac  bridge  shown  below  is  used  to measure  an  impedance  z.  Thebridge is in balanced condition. The impedance Z is equal to

Page 3: Made Easy Online Test Series e&M-1

Attempt Correct Correct Ans. cSolutionHave any doubt?FAQ?Video Solution

a.  series combination of a resistor and an inductorb.  parallel combination of a resistor and an inductor

c.  series combination of a resistor and a capacitord.  parallel combination of a resistor and a capacitor

Q.7

Attempt Incorrect Your Ans. b Correct Ans. aSolutionHave any doubt?FAQ?Video Solution

The bridge method commonly used for finding mutual inductance is

a.  Heaviside Campbell bridge

b.  Schering bridgec.  De Sauty bridged.  Wien bridge

Q.8

Attempt Correct Correct Ans. bSolutionHave any doubt?FAQ?Video Solution

A d.c. potentiometer is designed to measure up to about 2 V with a slidewire of 800 mm. A standard cell of emf 1.18 V obtains balance at 600mm. A test cell is seen to obtain balance at 680 mm. The emf of the testcell is

a.  1.00 V

b.  1.34 Vc.  1.50 Vd.  1.70 V

Q.9

SAR type analog to digital converter has a resolution of 20 mV. What willbe the digital output for an analog input of 2.16 V ?

Page 4: Made Easy Online Test Series e&M-1

Attempt Incorrect Your Ans. b Correct Ans. aSolutionHave any doubt?FAQ?Video Solution

a.  01101100

b.  01101011c.  01101101d.  none of these

Q.10

Attempt Incorrect Your Ans. 2 Correct Ans. 9.06 (9.00  9.50)SolutionHave any doubt?FAQ?Video Solution

The  reading  of  an  electrodynamometer  ammeter  when  a  current 

 is passed through it, will be _________ A.

Q.11

Attempt Incorrect Your Ans. 1 Correct Ans. 3.5 (3.45  3.55)SolutionHave any doubt?FAQ?Video Solution

A half wave rectifier type instrument 0–1 V is to be used for the voltagerange of  010 V.  _____ kΩ  is  the value of multiplier  resistance,  if  fullscale deflection is 1 mA. Neglect diode resistance i.e. (rd = 0).

Q.12

Attempt Incorrect Your Ans. 33.33 Correct Ans.6.25 (6.20  6.30)

SolutionHave any doubt?FAQ?Video Solution

A voltmeter reading 80 V on its 100 V range and an ammeter reading 80mA on its 150 mA range, are used to determine the power dissipated in aresistor. Both  these  instruments are guaranteed  to be accurate within±2%, at full scale deflection. The limiting error in the measurement of thepower dissipation is ________ %.

Q.13

Attempt Incorrect Your Ans. 0.22 Correct Ans.0.045 (0.041  0.047)

SolutionHave any doubt?FAQ?Video Solution

A set of independent current measurement taken by four observers wasrecorded  as:  115.02  mA,  115.11  mA,  115.08  mA  and  115.04  mA.  ±_______ mA will be the average range of error.

Page 5: Made Easy Online Test Series e&M-1

Q.14

Not Attempt Correct Ans. 2 (1.90  2.0)SolutionHave any doubt?FAQ?Video Solution

In a thermocouple based instrument, if 20% harmonic is present then theerror in the current reading is _______ %.

Q.15

Attempt Incorrect Your Ans. 875 Correct Ans. 8SolutionHave any doubt?FAQ?Video Solution

A digitaltoanalog converter with a fullscale output voltage of 3.5 V hasa resolution close to 14 mV. Its bit size is ________ .

Q.16

Not Attempt Correct Ans. 3.14 (3.10  3.20)SolutionHave any doubt?FAQ?Video Solution

An ac bridge shown below has the following specifications:C1 = 0.5 μF and R1 = 1 kΩ, R2= 2 kΩ, C3 = 0.5 μF.

If the supply frequency is 1 kHz, _______ will be the dissipation factor.

Q.17

Attempt Correct Correct Ans. bSolutionHave any doubt?FAQ?Video Solution

An energy meter rated as 5 A, 230 V makes 500 revolutions per kWh. Ifin  a  test  at  full  load  unity  power  factor,  it  makes  5  revolutions  in  30seconds. Then which of the following statement is true?

a.  The meter runs faster and error is 4.16%

b.  The meter runs faster and error is 4.35%c.  The meter runs slower and error is 4.16%d.  The meter runs slower and error is 4.35%

Page 6: Made Easy Online Test Series e&M-1

Q.18

Attempt Correct Correct Ans. dSolutionHave any doubt?FAQ?Video Solution

Figure shown below is the circuit of a capacitance comparison bridge. IfR1 = 20 Ω, R2 = 30 R3 = 25 Ω and C3 = 10 pF than the value of Rx and Cxare respectively

a.  27.5 Ω, 26/3 pFb.  30.5 Ω, 28/3 pFc.  35.5 Ω, 22/3 pF

d.  37.5 Ω, 20/3 pF

Q.19

Attempt Incorrect Your Ans. c Correct Ans. aSolutionHave any doubt?FAQ?Video Solution

Two 100 μA full scale PMMC meters are employed to construct a 10 Vand 100 V full scale voltmeter. These meters will have figures of merit(sensitivities) as

a.  10 kΩ/V and 10 kΩ/Vb.  100 kΩ/V and 10 kΩ/V

c.  10 kΩ/V and 100 kΩ/Vd.  10 kΩ/V and 1 kΩ/V

Q.20

Attempt Correct Correct Ans. d

The power flowing in a 3φ, 3 wire balanced load system is measured bythe two wattmeter method. The reading of wattmeter A is 500 watts andwattmeter B is –100 watts.The power factor of the system is

a.  0.866b.  0.707c.  0.567

d.  0.359

Page 7: Made Easy Online Test Series e&M-1

SolutionHave any doubt?FAQ?Video Solution

Q.21

Attempt Incorrect Your Ans. c Correct Ans. dSolutionHave any doubt?FAQ?Video Solution

The  current  passing  through  a  10  ohm  resistor  in  figure1,  has  thewaveform shown  in  figure2. The  reading of  the moving  iron voltmeterconnected across the resistor is

a.  0 Vb.  75 V

c.  85 V

d.  92 V

Q.22

Not Attempt Correct Ans. aSolutionHave any doubt?FAQ?Video Solution

A Wheatstone bridge is shown in figure below.If P = 2 kΩ, R = 2 kΩ, S = 5 kΩ, G = 100 Ω, Ecd = 24 mV and galvanometer

current Ig = 13.6 μA, the value of Q is

a.  0.2688 kΩb.  0.2466 kΩc.  0.2966 kΩd.  0.231 kΩ

Page 8: Made Easy Online Test Series e&M-1

Q.23

Attempt Incorrect Your Ans. c Correct Ans. dSolutionHave any doubt?FAQ?Video Solution

A thermocouple instrument reads 10 A at full scale. The current at whichit reads 1/3 rd of its full scale is

a.  3.33 Ab.  5 A

c.  6.66 A

d.  5.77 A

Q.24

Not Attempt Correct Ans. dSolutionHave any doubt?FAQ?Video Solution

The inductance of a moving iron instrument is given by:

L = (10 + 5θ – θ2)μHwhere  θ  is  the  deflection  in  radian  from  zero  position.  The  spring

constant is 12 × 10–6 Nm/rad. Estimate the deflection for a current of 5A.

a.  93.8°b.  94.8°c.  95.8°

d.  96.8°

Q.25

Attempt Correct Correct Ans. bSolutionHave any doubt?FAQ?Video Solution

The wattmeter commonly used for power measurement at commercialfrequencies is of the Xtype. This meter consists of two coil systems, thefixed system being the Ycoil and moving system being the Zcoil. Here,X, Y and Z respectively stands for

a.  dynamometer, voltage and current

b.  dynamometer, current and voltagec.  induction meter, voltage and currentd.  induction meter, current and voltage

Q.26

For an electrodynamometer ammeter. The mutual inductance M varieswith deflection θ(θ is in degree) as M = – 6 cos (θ + 45°) mH.For a direct current of 50 mA corresponding to a deflection of 60°, thedeflecting torque will be _____ μNm .

Page 9: Made Easy Online Test Series e&M-1

Attempt Incorrect Your Ans. 5 Correct Ans.14.49 (14.40  14.50)

SolutionHave any doubt?FAQ?Video Solution

Q.27

Attempt Incorrect Your Ans. 15 Correct Ans. 648 (640  655)SolutionHave any doubt?FAQ?Video Solution

In a moving coil instrument, the moving coil consists of 100 turns woundon a square former of length 3 cm. The flux density in the air gap is 0.06

T.  _____  ×  10–7  Nm  is  the  turning  moment  acting  on  the  coil  whencarrying a current of 12 mA.

Q.28

Attempt Incorrect Your Ans. 0.66 Correct Ans.1.06 (1.00  1.09)

SolutionHave any doubt?FAQ?Video Solution

A current of  i = 0.5 + 0.3 sinωt  –  0.2  sin 2ωt A  is passed  through  thecircuit shown in figure given below. _____ ampere is the sum of reading

of each instruments. (Take ω = 106 rad/s)

Q.29

Attempt Incorrect Your Ans. 800 Correct Ans. 431 (430  432)SolutionHave any doubt?FAQ?Video Solution

A voltage: 100 sinωt + 60 cos (3ωt – 30°) + 40 sin(5ωt + 45°)V is appliedto the pressure coil circuit of a wattmeter and through the current coil acurrent  of  8  sinωt  +  6  sin  (5ωt  +  120°)A  is  passed.  Reading  of  thewattmeter will be _______ W.

Q.30

A  conventional  rectifier  type  ac  voltmeter  (generally  has  a  fullwavebridge circuit with a PMMC meter calibrated  in  rms values)  is used  tomeasure a voltage given by

Page 10: Made Easy Online Test Series e&M-1

Not Attempt Correct Ans. 17 (16  18)SolutionHave any doubt?FAQ?Video Solution

                                              v(t) = V0 + 10 sin 314t volts

_______ volt will be the reading of the meter for V0 = 10 volts (assume

no diode drop and neglecting cutin voltage).

Q.31

Attempt Incorrect Your Ans. 00 Correct Ans.33.33 (33.30  33.40)

SolutionHave any doubt?FAQ?Video Solution

In the circuit shown below, voltage is measured by a voltmeter having asensitivity of 20 kΩ/volt and using the 10volt range. – _______ % will beerror in the measurement.

Q.32

Attempt Incorrect Your Ans. 1 Correct Ans. 3SolutionHave any doubt?FAQ?Video Solution

Suppose  that  resistor R1  and R2  are  connected  in  parallel  to  give  an

equivalent  resistance  R.  If  resistor  R1  and  R2  have  tolerance  of  1%

each,  the equivalent  resistance R  for R1  =  200 Ω and R2  =  100 Ω will

have tolerance of ________ %.

Q.33

The sawtooth voltage waveform shown in the figure is fed to a movingiron meter. Its reading will be _______ A.

Page 11: Made Easy Online Test Series e&M-1

Not Attempt Correct Ans. 4.082 (4.00  4.10)SolutionHave any doubt?FAQ?Video Solution