lista - webster

Upload: scheila-furquim

Post on 01-Mar-2016

20 views

Category:

Documents


0 download

DESCRIPTION

Alguns exercícios do Webster

TRANSCRIPT

CAPITULO 11.2 find the independent nonlinearity, as defined in figure 1.4(b), for the following set of inputs and outputs from a nearly linear system. Instrument was designed for an output equal to twice the input. Full scale is 20.Encontre a no-linearidade Independentes, conforme definido na figura 1.4 (b), para o seguinte conjunto de entradas e sadas de um sistema quase linear. Instrumento foi concebido para uma sada igual a duas vezes a entrada. Escala completa 20. 1.2 - find the correlation coefficient r for the set of five inputs and outputs given in problem 1.Encontrar o coeficiente de correlao r para o conjunto de cinco entradas e sadas de dados em um problema.A

1.5 - A Mercury thermometer has a cylindrical capillary tube with an internal diameter of 0,2 mm. If the volume of the thermometer and that of the bulb are not affect by temperature, what volume must the bulb have if a sensitivity of 2mm/C is to be obtained? Assume operation near 24C. assume that the stem volume is negligible compared with the bulb internal volume. Differential expansion coefficient of Hg = 1,82 x 10-4 ml/(ml.C)Um termmetro de mercrio tem um tubo capilar cilndrico com um dimetro interno de 0,2 mm. Se o volume do termmetro e que do bolbo no so influenciados pelo temperatura, o volume tem de ter a lmpada se uma sensibilidade de 2 milmetros / C para ser obtida? Suponha operao quase 24C. supor que o volume da haste negligencivel em comparao com o volume interno do bulbo. Coeficiente de expanso diferencial de Hg = 1,82 x 10-4 ml / (ml.C)

1.8 - A low-pass first-order instrument has a time constant of 20 ms. Find th frequency, in hertz, of the input at which the output will be 93% of the dc output. Find the phase angle at this frequency.Um instrumento de passagem baixa de primeira ordem tem uma constante de tempo de 20 ms. Encontrar th frequncia, em hertz, do sinal ao qual a sada ser 93% da sada de CC. Encontre o ngulo de fase nesta freqncia.

1.9 - A second-order instrument has a damping ratio of 0,4 and an undamped natural frequency of 85 Hz. Sketch the step response, ad give numerical values for the amplitude and time of the first two positive maxima. Assume that the input goes from 0 to 1and that the static sensitivity is 10.Um instrumento de segunda ordem tem uma razo de amortecimento de 0,4 e uma freqncia natural no amortecida de 85 Hz. Esboar a resposta ao degrau, ad dar valores numricos para a amplitude e tempo dos dois primeiros maxima positivo. Suponhamos que a entrada vai de 0 a 1 e que a sensibilidade esttico 10.

CAPITULO 22.2 the practical limitation for wire spacing in potentiometer construction is between 20 and 40 turns/mm. Find the resolution limitation for a translational and rotational potentiometer. Propose a way to increase the resolution of a rotational potentiometer.a limitao prtica para o espaamento de arame na construo potencimetro entre 20 e 40 voltas / mm. Encontre a limitao de resoluo para um potencimetro de translao e rotao. Propor uma forma de aumentar a resoluo de um potencimetro de rotao.

2.4 The electromotive force E for a thermocouple is given by (2.21). Calculate and plot E for conditions in which the reference source is at 0C and temperature varies from 0 CV to 50 C. The thermocouple material os copper constantan with a=38,7mV/C and b=0,082mV/C2. How significant is the second term in your calculations? Note that these calculated curves are not exactly satisfied in the practical situation. Thus an experimental calibration must be measured over the range of interest.A fora electromotriz E para um termopar dada por (2.21). Calcule e enredo E para as condies em que a fonte de referncia a 0C e temperatura varia de 0 a 50 C. CV O material termopares de constantan de cobre com a = 38,7mV / C e b = 0,082mV / C2. Como significativo o segundo termo em seus clculos? Note-se que estas curvas calculados no so exatamente satisfeito em cada situao concreta. Assim, uma calibrao experimental deve ser medido ao longo do intervalo de interesse.

2.5 using the results of problem 2.4, calculate the sensitivity (alfa) at 37C for the copper-constantan thermocouple.utilizando os resultados de problema 2.4, calcular a sensibilidade (alfa) a 37C para o termopar de cobre-constantan.2.6 Calculate the value of the thermistor temperature coefficient (alfa) for T=300K and b=4000KCalcula-se o valor do coeficiente de temperatura da sonda (alfa) para T = 300K e b = 4000K

2.8 For example 2.1, what size shunting capacitor should be added to extend the low-corner frequency to 0,05 Hz, as is required to detect pulse waveforms? How is the sensitivity changed?Por exemplo 2.1, o capacitor shunt tamanho deve ser adicionada para estender a frequncia baixa canto para 0,05 Hz, como necessrio para detectar as formas de onda de pulso? Como a sensibilidade alterada?

2.11 Calculate and sketch a curve for the rediant output of the skin at 300 K at 2000, 5000, 10000 and 20000 nm.Calcular e esboar uma curva para a sada radiante da pele a 300 K a 2000, 5000, 10000 e 20000 nm.

2.16 For figure 2.21 (d), plot the relative combination product for GaP, HbO, CdS.Para figura 2.21 (d), plotar o produto de combinao relativa para Gap, HBO, CDs.

CAPITULO 44.1 what are the four main factors involved in the movement of ions across the cell membrane in the steady-state condition?Quais so os quatro principais fatores envolvidos no movimento de ons atravs da membrana celular na condio de estado estacionrio?

4.2 Assume that life on Mars requires an anterior cell potential of +100mV and that the extracellular cancentrations of the three major species are as given in Example 4.1. Choose one species that has the permeability coefficient given, and assume the other two permeabilities are zero. Design the cell by calculating the concentration of the chosen species.Assume-se que a vida em Marte requer um potencial celular de 100 mV anterior e que as concentraes extracelulares de as trs espcies principais esto indicados no Exemplo 4.1. Escolha uma espcie que tem o coeficiente de permeabilidade dada, e assumir os outros dois permeabilidades so zero. Desenhar a clula atravs do clculo da concentrao das espcies escolhidas.

4.3 An excitable cell is impaled by a micropipette, and a second extracellular electrode is placed close by at the outer-membrane suface. Brief pulses of current are then passed between these electrodes, which may cause it to conduct an action potential. Explain how the polarity of the stimulating pair influences the membrane potential, and subsequently the activity, of the excitable cell.Uma clula excitvel empalado por uma micropipeta, e um segundo elctrodo extracelular colocado perto na superfcie da membrana externa de uma. Breves pulsos de corrente so ento passadas entre esses eletrodos, que o podero levar a realizar um potencial de ao. Explicar como a polaridade do par estimulante influencia o potencial de membrana, e, subsequentemente, a actividade, da clula excitvel.

4.8 An excised, active nerve trunk serves as a bioelectricsource located on the axis of a circular cylindrical volume conductor. Field potentials are recorded at various radial distances from the nerve trunk from an appropriate electrode assembly connected to an amplifier. A) Describe the behavior of the field potential with increasing radial distance from the nerver (angle and axial distance are fixed). B) describe de effect of increasing the specific resistivity (p) of the bathing medium on the magnitude of the field potential, and explain how this change in (p) might be accomplished experimentally. C) In whatmanner would changing the radius of the surrounding volume-conductor affect the magnitude and waveshape of the extracellular field potential? D) When can avolume condutctor of finite dimension be considered an essentially infinite volume conductor?Um, tronco do nervo activo excisado serve como uma fonte bioelctrico localizado no eixo de um volume condutor cilndrico circular. Potenciais de campo so registradas em vrias distncias radiais a partir do tronco do nervo de um conjunto de elctrodos apropriado ligado a um amplificador. A) Descrever o comportamento do potencial de campo com o aumento da distncia radial a partir do nervo (ngulo e distncia axial so fixos). B) descrever o efeito de aumentar a resistividade especfica (p) do meio do banho sobre a magnitude do campo potencial, e explicar como essa mudana de (p) pode ser conseguida experimentalmente. C) Em que forma iria alterar o raio do volume condutor envolvente afectam a magnitude e forma de onda do campo potencial extracelular? D) Quando que um volume condutor de dimenso finita ser considerado um volume condutor essencialmente "infinito"?

4.11 In many forms of peripheral neuropathies, the excitability of some neurons is change, and their conduction velocities are consequently altered.DesenhoDescribe the effect that this might fave on an EMG recording and on muscular constraction.

Em muitas formas de neuropatias perifricas, a excitabilidade de alguns neurnios a mudana, e as suas velocidades de conduo so consequentemente alteradaDESENHODescrever o efeito que isso pode ter sobre uma gravao de ECG e na contrao muscular.

4.15 Draw a typical lead II electrocardiogram and label all waves (P, QRS, T) and intervals. Explain what is happening electrically within the heart during each wave or interval.Desenhe um tpico eletrocardiograma II e rotular todas as ondas (P, QRS, T) e intervalos. Explique o que est acontecendo eletricamente dentro do corao durante cada onda ou intervalo.

4.17 Why is it necessary for the ventricular action potential to have a relatively long absolute refractory period?Por que necessrio que o potencial de ao ventricular para ter um perodo refratrio absoluto relativamente longo?

4.19 Explain the components of the ERG in terms of retinal cell activity.Explicar os componentes do ERG em termos de atividade das clulas da retina.

4.24 Discuss in general terms the design of a spectrum analyzed for automatic analynhsis of EEG waves.Discutir em termos gerais a criao de um analisador de espectro para a anlise automtica das ondas do EEG.