Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.
Document Number: N/A
Revision Number: 2 Re-Issued for Permit
Revision Date: 16-Mar-2018
Updated By: K. Johnson
Locator Code Facility Equipment Tag
Number
Equipment Name Major Equipment Type Detail Description Capacity Motor (If Applicable) Physical Dimensions
(Approximate)
Additional Fluid Weight
(Approximate lb.)
Material(s) Comments
LSF1 Las Flores Pump Station SK-1100 Meter Skid - Exxon-Mobil - L-901R Meter 40' L x 6' W
Weight: 20,000 lb.
2,447 Carbon steel
LSF1 Las Flores Pump Station PVR-1200 Meter Prover (Fixed) - L-901R Meter Prover 57' L x 10'-6" W
Weight: 25,000 lb.
14,281 Carbon steel
LSF1 Las Flores Pump Station P-1300A Mainline Shipping Pump - L-901R Pump 169.5" L x 69.5" W
Weight: 11,300 lb.
2,000 XXXXX
LSF1 Las Flores Pump Station P-1300B Mainline Shipping Pump - L-901R Pump 169.5" L x 69.5" W
Weight: 11,300 lb.
2,000 XXXXX
LSF1 Las Flores Pump Station TRP-1400 Pig Launcher - L-901R Pig Launcher 21'-10"' L x 6' W
Weight: 12,950 lb.
1,957 Carbon steel
LSF1 Las Flores Pump Station T-1500 Drain Tank Tank 64.5" OD x 72" H primary
74.5" OD x 75" H
secondary
Weight: 5,745 lb.
8,482 Carbon steel
(internally, externally coated)
LSF1 Las Flores Pump Station P-1510 Drain Pump Pump Part of Drain Tank T-1500 100 All Iron w/ 416 SST shaft
LSF1 Las Flores Pump Station T-1600 Bactericide Tank Tank 3' L x 3' W
Weight: XXXX lb.
2,800 316 SST
LSF1 Las Flores Pump Station P-1610 Bactericide Injection Pump Pump XXXXX N/A XXXXX
GVT1 Gaviota Pump Station TRP-2100 Pig Receiver - L-901R Pig Receiver 26'-11"' L x 6' W
Weight: 13,230 lb.
2,447 Carbon steel
GVT1 Gaviota Pump Station SK-2200 Check Meter Skid - L-901R Meter 30' L x 6' W
Weight: 20,000 lb.
2,447 Carbon steel
GVT1 Gaviota Pump Station P-2300A Mainline Booster Pump - L-901R Pump 179" L x 69.5" W
Weight: 14,190 lb.
2,000 XXXXX
GVT1 Gaviota Pump Station P-2300B Mainline Booster Pump - L-901R Pump 179" L x 69.5" W
Weight: 14,190 lb.
2,000 XXXXX
GVT1 Gaviota Pump Station TRP-2400 Pig Launcher - L-901R Pig Launcher 23'-8" L x 6'-8" W
Weight: 18,200 lb.
4,349 Carbon steel
GVT1 Gaviota Pump Station T-2500 Drain Tank Tank 64.5" OD x 72" H primary
74.5" OD x 75" H
secondary
Weight: 5,745 lb.
8,482 Carbon steel
(internally, externally coated)
GVT1 Gaviota Pump Station P-2510 Drain Pump Pump Part of Drain Tank T-2500 100 All Iron w/ 416 SST shaft
GVT1 Gaviota Pump Station T-2600 Bactericide Tank Tank 3' L x 3' W
Weight: XXXX lb.
2,800 316 SST
GVT1 Gaviota Pump Station P-2610 Bactericide Injection Pump Pump XXXXX N/A XXXXX
PROPOSED MECHANICAL EQUIPMENT LIST
L-903-903 Replacement 1 of 3
Plains2017SBC-1_0002769
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.
Document Number: N/A
Revision Number: 2 Re-Issued for Permit
Revision Date: 16-Mar-2018
Updated By: K. Johnson
Locator Code Facility Equipment Tag
Number
Equipment Name Major Equipment Type Detail Description Capacity Motor (If Applicable) Physical Dimensions
(Approximate)
Additional Fluid Weight
(Approximate lb.)
Material(s) Comments
PROPOSED MECHANICAL EQUIPMENT LIST
SIC1 Sisquoc Pump Station TRP-3100 Pig Receiver - L-901R Pig Receiver 27'-6" L x 6'-8" W
Weight: 20,100 lb.
5,219 Carbon steel
SIC1 Sisquoc Pump Station SK-3200 Check Meter Skid - L-901R Meter 30' L x 6' W
Weight: 20,000 lb.
4,349 Carbon steel
SIC1 Sisquoc Pump Station T-XXXX Crude Oil Break-Out Tank Tank 134' Dia. X 48'
Weight: 910,000 lb.
42,172,443 Carbon steel
SIC1 Sisquoc Pump Station MX-XXXX Crude Oil Break-Out Tank Mixer Mixer / Agitator Part of Tank T-XXXXX N/A TBD
SIC1 Sisquoc Pump Station P-3300 Crude Oil Booster Pump Pump 3'-2" L x 3'-2"' W
Weight: 4,345 lb.
1,000 Carbon steel bowl, suction bell,
column, discharge head, can;
ductile iron impeller; 416SS bowl
shaft, column shaft
SIC1 Sisquoc Pump Station P-3310 Crude Oil Booster Pump Pump 3'-2" L x 3'-2"' W
Weight: 4,345 lb.
1,000 Carbon steel bowl, suction bell,
column, discharge head, can;
ductile iron impeller; 416SS bowl
shaft, column shaft
SIC1 Sisquoc Pump Station H-3400 Crude Oil Heater Fired Heater 55' L x 14' W
Weight: 62,000 lb.
6,100 lb. Carbon steel
SIC1 Sisquoc Pump Station H-3410 Crude Oil Heater Fired Heater 55' L x 14' W
Weight: 62,000 lb.
6,100 lb. Carbon steel
SIC1 Sisquoc Pump Station BL-3400 Burner Blower (Fan) Blower Part of Crude Oil Heater H-
3400
N/A Carbon steel
SIC1 Sisquoc Pump Station BL-3410 Burner Blower (Fan) Blower Part of Crude Oil Heater H-
3410
N/A Carbon steel
SIC1 Sisquoc Pump Station P-3500 Mainline Shipping Pump - L-903R Pump 188.5" L x 69.5" W
Weight: 17,430 lb.
2,000 XXXXX
SIC1 Sisquoc Pump Station P-3510 Mainline Shipping Pump - L-903R Pump 188.5" L x 69.5" W
Weight: 17,430 lb.
2,000 XXXXX
SIC1 Sisquoc Pump Station SK-3600 Check Meter Skid - L-903R Meter 30' L x 6' W
Weight: 20,000 lb.
3,330 Carbon steel
SIC1 Sisquoc Pump Station TRP-3700 Pig Launcher - L-903R Pig Launcher 20'-3" L x 2'-6" W
Weight: 14,000 lb.
3,330 Carbon steel
SIC1 Sisquoc Pump Station T-3800 Drain Tank Tank 64.5" OD x 72" H primary
74.5" OD x 75" H
secondary
Weight: 5,745 lb.
8,482 Carbon steel
(internally, externally coated)
SIC1 Sisquoc Pump Station P-3810 Drain Pump Pump Part of Drain Tank T-3800 100 All Iron w/ 416 SST shaft
SIC1 Sisquoc Pump Station T-3900 Fire Water Tank Tank 46'-6" Dia. x 40' Ht.
Weight: 241,000 lb.
4,231,982 Carbon steel
SIC1 Sisquoc Pump Station P-3910A Fire Water Pump Pump ~ 7' L x 3' W
Weight: 3,000 lb.
150 xxxxxxxx
SIC1 Sisquoc Pump Station P-3910B Fire Water Pump Pump ~ 7' L x 3' W
Weight: 3,000 lb.
150 xxxxxxxx
L-903-903 Replacement 2 of 3
Plains2017SBC-1_0002770
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.
Document Number: N/A
Revision Number: 2 Re-Issued for Permit
Revision Date: 16-Mar-2018
Updated By: K. Johnson
Locator Code Facility Equipment Tag
Number
Equipment Name Major Equipment Type Detail Description Capacity Motor (If Applicable) Physical Dimensions
(Approximate)
Additional Fluid Weight
(Approximate lb.)
Material(s) Comments
PROPOSED MECHANICAL EQUIPMENT LIST
SIC1 Sisquoc Pump Station T-3920 Foam Concentrate Tank Tank 15' Dia. x 16' Ht.
Weight: 25,200 lb.
176,149 Carbon steel
SIC1 Sisquoc Pump Station SK-3930 Foam Proportioning Skid FW System 8' L x 6' W
Weight: 10,000 lb.
1,000 Carbon steel
SIC1 Sisquoc Pump Station T-3950 Bactericide Tank Tank 3' L x 3' W
Weight: XXXX lb.
2,800 316 SST
SIC1 Sisquoc Pump Station P-3960 Bactericide Injection Pump Pump XXXXX N/A XXXXX
RRA1 Russell Ranch Pump Station TRP-4100 Pig Receiver - L-903R Pig Receiver 27'-4" L x 6'-4" W
Weight: 15,450 lb.
3,996 Carbon steel
RRA1 Russell Ranch Pump Station SK-4200 Check Meter Skid - L-903R Meter 30' L x 6' W
Weight: 20,000 lb.
3,996 Carbon steel
RRA1 Russell Ranch Pump Station P-4300A Mainline Booster Pump - L-903R Pump 188.5" L x 69.5" W
Weight: 17,430 lb.
2,000 XXXXX
RRA1 Russell Ranch Pump Station P-4300B Mainline Booster Pump - L-903R Pump 197" L x 69.5" W
Weight: 15,000 lb.
XXXX XXXXX
RRA1 Russell Ranch Pump Station TRP-4400 Pig Launcher - L-903R Pig Launcher 22'-4" L x 6'-4" W
Weight: 14,000 lb.
3,996 Carbon steel
RRA1 Russell Ranch Pump Station T-4500 Drain Tank Tank 64.5" OD x 72" H primary
74.5" OD x 75" H
secondary
Weight: 5,745 lb.
8,482 Carbon steel
(internally, externally coated)
RRA1 Russell Ranch Pump Station P-4510 Drain Pump Pump Part of Drain Tank T-4500 100 All Iron w/ 416 SST shaft
RRA1 Russell Ranch Pump Station T-4600 Bactericide Tank Tank 3' L x 3' W
Weight: XXXX lb.
2,800 316 SST
RRA1 Russell Ranch Pump Station P-4610 Bactericide Injection Pump Pump XXXXX N/A XXXXX
PN Pentland Delivery Point TRP-5100 Pig Receiver - L-903R Pig Receiver 29'-0" L x 2'-6" W
Weight: 15,450 lb.
XXXX Carbon steel
L-903-903 Replacement 3 of 3
Plains2017SBC-1_0002771
L-901/903 Replacement Project
Plains Pipeline, L.P.
Document Number: N/A
Revision Number: 0
Revision Date: 16-Mar-2018
Updated By: SCS Engineers
County Facility Existing - Equipment Name Major Equipment Type Detail Description (Specs) PTO Number Remove/Remain/New
Santa Barbara Las Flores Pump Station 1.1 Mainline Pump Pump 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 1.2 Mainline Pump Pump 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 1.3 Electrict Motor for Mainline Pump Motor 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 1.4 Electric Motor for Mainline Pump Motor 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 7 Meter Meter 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 9 Meter Prover Meter Prover 09502 - R6 To be removed
Santa Barbara Las Flores Pump Station 10 Sump Tank Tank 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 12 Sump Pump Pump 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 12.1 Electric Motor for Sump Pump Motor 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station 13 Sump Injection Pump Pump 09502 - R6 To be removed
Santa Barbara Las Flores Pump Station 13.1 Electric Motor for Sump Pump Pump 09502 - R6 To be removed
Santa Barbara Las Flores Pump Station 14 Scraper Launcher Pig Launcher 09502 - R6 Remove - to be replaced with new
Santa Barbara Las Flores Pump Station Bactericide Tank Tank 14552 To remain
Santa Barbara Las Flores Pump Station Bactericide Tank Pump Electric Pump 14552 To remain
Santa Barbara Sisquoc Pump Station 1.1 Mainline Pump Pump 05891 - R8 Remove - to be replaced with new
Santa Barbara Sisquoc Pump Station 1.2 Mainline Pump Pump 05891 - R8 Remove - to be replaced with new
Santa Barbara Sisquoc Pump Station 1.3 Sump Booster Pump Pump 05891 - R8 Remove - to be replaced with new
Santa Barbara Sisquoc Pump Station 1.4 Sump Injection Pump Pump 05891 - R8 To be removed
Santa Barbara Sisquoc Pump Station 4 Sump Tank Tank 05891 - R8 Remove - to be replaced with new
Santa Barbara Sisquoc Pump Station 8 Scraper Launcher Pig Launcher 05891 - R8 Remove - to be replaced with new
Santa Barbara Sisquoc Pump Station 9 Scraper Receiver Pig Receiver 05891 - R8 Remove - to be replaced with new
Santa Barbara Sisquoc Pump Station IC Diesel Generator Generator 11689 - R2 Remove - to be replaced with new
Santa Barbara Sisquoc Pump Station Bactericide Tank Tank 05891 - R8 To remian
Santa Barbara Sisquoc Pump Station Bactericide Tank Pump Electric Pump 05891 - R8 To remian
Santa Barbara Gaviota Pump Station 1.1 Mainline Pump Pump 07364 - R6 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station 1.2 Sump Pump Pump 07364 - R6 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station 1.3 Sump Pump Pump 07364 - R6 To be removed
Santa Barbara Gaviota Pump Station 1.4 Mainline Pump Pump 07364 - R6 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station 4 Meter Meter 07364 - R6 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station 6 Meter Prover Meter Prover 07364 - R6 To be removed
Santa Barbara Gaviota Pump Station 7 Sump Tank Tank 07364 - R6 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station 10 Scraper Launcher Pig Launcher 07364 - R6 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station 11 Scraper Receiver Pig Receiver 07364 - R6 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station E 1 Mainline Pump (De-Permitted) Pump 07364 - R6 To be removed
Santa Barbara Gaviota Pump Station IC Diesel Generator Generator 11688 - R2 Remove - to be replaced with new
Santa Barbara Gaviota Pump Station Bactericide Tank Tank 14553 To remain
Santa Barbara Gaviota Pump Station Bactericide Tank Pump Electric Pump 14553 To remain
Santa Barbara Valve Station 1-400 (MOV Gate Valve) IC Diesel Generator Generator 11693 Remove - to be replaced with new
Santa Barbara Valve Station 2-300 (MOV Gate Valve) IC Diesel Generator Generator 11690 Remove - to be replaced with new
Santa Barbara Valve Station 2-800 (MOV Gate Valve) IC Diesel Generator Generator 11691 Remove - to be replaced with new
Santa Barbara Valve Station 2-1400 (MOV Gate Valve) IC Diesel Generator Generator 11694 Remove - to be replaced with new
Santa Barbara Valve Station 3-700 (MOV Gate Valve) IC Diesel Generator Generator 11692 Remove - to be replaced with new
EXISTING PERMITTED MECHANICAL EQUIPMENT LIST
Plains2017SBC-1_0002772
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.
ELECTRICAL EQUIPMENT LIST
Document Number: N/A
Revision Number: 2 Re-Issued for Permit
Revision Date: 16-Mar-2018
Updated By: K. Johnson
Locator Code Facility Associated Equipment Tag Number (If
Any)
Equipment Tag No. Equipment Name Type Equipment Description kVA
Rating
HP
Rating
kW
Rating
Voltage Rating (V) Design
Current (A)
Current
Rating (A)
No. Phases Frequency
(Hz)
Physical Dimensions
(Approximate)
Comments
LSF1 Las Flores Pump Station N/A FS-1 Primary Protection Protection N/A
LSF1 Las Flores Pump Station N/A GFD-1 Ground Fault Detector Protection 16" x 14"
LSF1 Las Flores Pump Station N/A XFMR-1 Primary Transformer Transformer 75" x 120"
LSF1 Las Flores Pump Station N/A XFMR-2 Ancillary Load Transformer Transformer 89" x 53"
LSF1 Las Flores Pump Station N/A TBD Power and Control Building Building XXXX
LSF1 Las Flores Pump Station N/A CB-1 MV SWGR Protection Protection N/A
LSF1 Las Flores Pump Station N/A SWGR-1 MV Motor Control Switchgear Switchgear 108" x 54"
LSF1 Las Flores Pump Station N/A MCC-1 LV Motor Control Center MCC 168" x 30"
LSF1 Las Flores Pump Station N/A TBD PLC Control Panel PLC TBD
LSF1 Las Flores Pump Station P-1300A M-1300A Crude Oil Shipping Pump Motor Motor XX' L x XX' W
LSF1 Las Flores Pump Station P-1300B M-1300B Crude Oil Shipping Pump Motor Motor XX' L x XX' W
LSF1 Las Flores Pump Station M-1300A VFD-1300A Crude Oil Shipping Pump Motor VFD VFD 122" x 43"
LSF1 Las Flores Pump Station M-1300B VFD-1300B Crude Oil Shipping Pump Motor VFD VFD 122" x 43"
LSF1 Las Flores Pump Station P-1510 M-1510 Drain Pump Motor Motor N/A
LSF1 Las Flores Pump Station N/A TBD Emergency Diesel Generator Generator XX' L x XX' W
LSF1 Las Flores Pump Station P-1610 M-1610 Bactericide Injection Pump Motor Motor XX' L x XX' W
GVT1 Gaviota Pump Station N/A FS-1 Primary Protection Protection N/A
GVT1 Gaviota Pump Station N/A GFD-1 Ground Fault Detector Protection 16" x 14"
GVT1 Gaviota Pump Station N/A XFMR-1 Primary Transformer Transformer 75" x 120"
GVT1 Gaviota Pump Station N/A XFMR-2 Ancillary Load Transformer Transformer 89" x 53"
GVT1 Gaviota Pump Station N/A TBD Power and Control Building Building XXXX
GVT1 Gaviota Pump Station N/A CB-1 MV SWGR Protection Protection N/A
GVT1 Gaviota Pump Station N/A SWGR-1 MV Motor Control Switchgear Switchgear 108" x 54"
GVT1 Gaviota Pump Station N/A MCC-1 LV Motor Control Center MCC 168" x 30"
GVT1 Gaviota Pump Station N/A TBD PLC Control Panel PLC TBD
GVT1 Gaviota Pump Station P-2300A M-2300A Crude Oil Shipping Pump Motor Motor XX' L x XX' W
GVT1 Gaviota Pump Station P-2300B M-2300B Crude Oil Shipping Pump Motor Motor XX' L x XX' W
GVT1 Gaviota Pump Station M-2300A VFD-2300A Crude Oil Shipping Pump Motor VFD VFD 104" x 60" x 48"
Frame A4
GVT1 Gaviota Pump Station M-2300B VFD-2300B Crude Oil Shipping Pump Motor VFD VFD 104" x 60" x 48"
Frame A4
GVT1 Gaviota Pump Station P-2510 M-2510 Drain Pump Motor Motor N/A
GVT1 Gaviota Pump Station N/A TBD Emergency Diesel Generator Generator XX' L x XX' W
GVT1 Gaviota Pump Station P-2610 M-2610 Bactericide Injection Pump Motor Motor XX' L x XX' W
L-901-903 Replacement 1 of 3
Plains2017SBC-1_0002773
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.
ELECTRICAL EQUIPMENT LIST
Document Number: N/A
Revision Number: 2 Re-Issued for Permit
Revision Date: 16-Mar-2018
Updated By: K. Johnson
Locator Code Facility Associated Equipment Tag Number (If
Any)
Equipment Tag No. Equipment Name Type Equipment Description kVA
Rating
HP
Rating
kW
Rating
Voltage Rating (V) Design
Current (A)
Current
Rating (A)
No. Phases Frequency
(Hz)
Physical Dimensions
(Approximate)
Comments
SIC1 Sisquoc Pump Station N/A FS-1 Primary Protection Protection N/A
SIC1 Sisquoc Pump Station N/A GFD-1 Ground Fault Detector Protection 16" x 14"
SIC1 Sisquoc Pump Station N/A XFMR-1 Primary Transformer Transformer 75" x 120"
SIC1 Sisquoc Pump Station N/A XFMR-2 Ancillary Load Transformer Transformer 89" x 53"
SIC1 Sisquoc Pump Station N/A TBD Power and Control Building Building XXXX
SIC1 Sisquoc Pump Station N/A CB-1 MV SWGR Protection Protection N/A
SIC1 Sisquoc Pump Station N/A SWGR-1 MV Motor Control Switchgear Switchgear 108" x 54"
SIC1 Sisquoc Pump Station N/A MCC-1 LV Motor Control Center MCC 168" x 30"
SIC1 Sisquoc Pump Station N/A TBD PLC Control Panel PLC TBD
SIC1 Sisquoc Pump Station T-XXXXX M-XXXXX Crude Oil Break-Out Tank
Mixer Motor
Motor N/A
SIC1 Sisquoc Pump Station P-3300 M-3300 Crude Oil Booster Pump Motor Motor XX' L x XX' W
SIC1 Sisquoc Pump Station P-3310 M-3310 Crude Oil Booster Pump Motor Motor XX' L x XX' W
SIC1 Sisquoc Pump Station M-3300 VFD-3300 Crude Oil Booster Pump Motor VFD VFD 122" x 43"
SIC1 Sisquoc Pump Station M-3310 VFD-3310 Crude Oil Booster Pump Motor VFD VFD 122" x 43"
SIC1 Sisquoc Pump Station BL-3400 M-3400 Crude Oil Heater
Burner Fan Motor
Motor N/A
SIC1 Sisquoc Pump Station BL-3410 M-3410 Crude Oil Heater
Burner Fan Motor
Motor N/A
SIC1 Sisquoc Pump Station M-3400 VFD-3400 Crude Oil Heater
Burner Fan Motor VFD
VFD
SIC1 Sisquoc Pump Station M-3410 VFD-3410 Crude Oil Heater
Burner Fan Motor VFD
VFD
SIC1 Sisquoc Pump Station P-3500 M-3500 Crude Oil Shipping Pump Motor Motor XX' L x XX' W
SIC1 Sisquoc Pump Station P-3510 M-3510 Crude Oil Shipping Pump Motor Motor XX' L x XX' W
SIC1 Sisquoc Pump Station M-3500 VFD-3500 Crude Oil Shipping Pump Motor VFD VFD 122" x 43"
SIC1 Sisquoc Pump Station M-3510 VFD-3510 Crude Oil Shipping Pump Motor VFD VFD 122" x 43"
SIC1 Sisquoc Pump Station P-3810 M-3810 Drain Pump Motor Motor
SIC1 Sisquoc Pump Station P-3910A M-3910A Fire Water Pump Motor Motor XXXX
SIC1 Sisquoc Pump Station P-3910B M-3910B Fire Water Pump Motor Motor XXXX
SIC1 Sisquoc Pump Station N/A TBD Emergency Diesel Generator Generator XX' L x XX' W
SIC1 Sisquoc Pump Station P-3960 M-3960 Bactericide Injection Pump Motor Motor XX' L x XX' W
L-901-903 Replacement 2 of 3
Plains2017SBC-1_0002774
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.
ELECTRICAL EQUIPMENT LIST
Document Number: N/A
Revision Number: 2 Re-Issued for Permit
Revision Date: 16-Mar-2018
Updated By: K. Johnson
Locator Code Facility Associated Equipment Tag Number (If
Any)
Equipment Tag No. Equipment Name Type Equipment Description kVA
Rating
HP
Rating
kW
Rating
Voltage Rating (V) Design
Current (A)
Current
Rating (A)
No. Phases Frequency
(Hz)
Physical Dimensions
(Approximate)
Comments
RRA1 Russell Ranch Pump Station N/A FS-1 Primary Protection Protection N/A
RRA1 Russell Ranch Pump Station N/A GFD-1 Ground Fault Detector Protection 16" x 14"
RRA1 Russell Ranch Pump Station N/A XFMR-1 Primary Transformer Transformer 75" x 120"
RRA1 Russell Ranch Pump Station N/A XFMR-2 Ancillary Load Transformer Transformer 89" x 53"
RRA1 Russell Ranch Pump Station N/A TBD Power and Control Building Building XXXX
RRA1 Russell Ranch Pump Station N/A CB-1 MV SWGR Protection Protection N/A
RRA1 Russell Ranch Pump Station N/A SWGR-1 MV Motor Control Switchgear Switchgear 108" x 54"
RRA1 Russell Ranch Pump Station N/A MCC-1 LV Motor Control Center MCC 168" x 30"
RRA1 Russell Ranch Pump Station N/A TBD PLC Control Panel PLC TBD
RRA1 Russell Ranch Pump Station P-4300A M-4300A Crude Oil Shipping Pump Motor Motor XX' L x XX' W
RRA1 Russell Ranch Pump Station P-4300B M-4300B Crude Oil Shipping Pump Motor Motor XX' L x XX' W
RRA1 Russell Ranch Pump Station M-4300A VFD-4300A Crude Oil Shipping Pump Motor VFD VFD 122" x 43"
RRA1 Russell Ranch Pump Station M-4300B VFD-4300B Crude Oil Shipping Pump Motor VFD VFD 122" x 43"
RRA1 Russell Ranch Pump Station P-4510 M-4510 Drain Pump Motor Motor N/A
RRA1 Russell Ranch Pump Station N/A TBD Emergency Diesel Generator Generator XX' L x XX' W
RRA1 Russell Ranch Pump Station P-4610 M-4610 Bactericide Injection Pump Motor Motor XX' L x XX' W
L901R Line 901R V1-200 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V1-400 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V1-600 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V1-800 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V1-900 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V1-1000 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-300 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-500 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-700 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-800 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-1000 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-1200 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-1300 TBD Emergency Diesel Generator Generator XX' L x XX' W
L901R Line 901R V2-1400 TBD Emergency Diesel Generator Generator XX' L x XX' W
L903R Line 903R V3-300 TBD Emergency Diesel Generator Generator XX' L x XX' W
L903R Line 903R V3-600 TBD Emergency Diesel Generator Generator XX' L x XX' W
L903R Line 903R V3-700 TBD Emergency Diesel Generator Generator XX' L x XX' W
L903R Line 903R V3-900 TBD Emergency Diesel Generator Generator XX' L x XX' W
L903R Line 903R V4-800 TBD Emergency Diesel Generator Generator XX' L x XX' W
L903R Line 903R V4-900 TBD Emergency Diesel Generator Generator XX' L x XX' W
L903R Line 903R V4-1000 TBD Emergency Diesel Generator Generator XX' L x XX' W
L-901-903 Replacement 3 of 3
Plains2017SBC-1_0002775
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.79 Amps
ELECTRICAL LOAD LIST - LAS FLORES PUMP STATION 65.9 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 10 kW 56 kW 0 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 480 Total 10.0 kW 186.5 kW 0.0 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-1510 Drain Pump Motor 11.49 8.57 15.00 11.19 0.77 0.930 1.000 0.85 9.21 5.71 3 NO 11.081
2 N/A Motor Operated Valves (Total) 180.00 134.23 180.00 134.23 1.00 0.924 1.000 0.85 145.27 90.03 3 NO 174.728
3 N/A Control Power,120 VAC N/A 10.00 N/A 0.00 1.00 1.000 1.000 1.00 10.00 0.00 1 NO 12.0281
4 N/A Area Lighting Panel N/A 2.00 N/A 0.00 1.00 1.000 1.000 1.00 2.00 0.00 3 NO 2.40563
5 N/A Heat Tracing Panel N/A 30.00 N/A 0.00 1.00 1.000 1.000 1.00 30.00 0.00 3 NO 36.0844
MCC-1
Total
Phase
Continuous Intermittent Stand-by
REV.
Stand-by
Cur
rent
(A)
Stat
us Bus
Sche
me
Type
VFD
Con
tact
or S
ize
Electrical Load List_Las Flores.xls\Las Flores - 480 V 1 of 2Plains2017SBC-1_0002776
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.53 Amps
ELECTRICAL LOAD LIST - LAS FLORES PUMP STATION 383.3 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 354 kW 0 kW 29 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 4,160 Total 354.5 kW 0.0 kW 288.5 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-1300A Mainline Shipping Pump Motor 349.20 260.40 500.00 372.85 0.70 0.950 0.950 0.85 288.53 178.82 3 NO 40.0445
2 M-1300B Mainline Shipping Pump Motor 349.20 260.40 500.00 372.85 0.70 0.950 0.950 0.85 288.53 178.82 3 NO 40.0445
3 480VAC-FEEDER 480 VAC Feeder 65.94 1.000 1.000 1.00 65.94 0.00 3 NO 9.15206
MVSG-1
Total
Continuous Intermittent Stand-by
Sche
me
Type
Cur
rent
(A)
Bus
Stand-by
REV. Phase
VFD
Con
tact
or S
ize
Stat
us
Electrical Load List_Las Flores.xls\Las Flores - 4.16kV 2 of 2Plains2017SBC-1_0002777
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.85 Amps
ELECTRICAL LOAD LIST - GAVIOTA PUMP STATION 70.8 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 10 kW 61 kW 0 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 480 Total 10.0 kW 202.6 kW 0.0 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-2510 Drain Pump Motor 31.26 23.31 40.00 29.83 0.78 0.920 1.000 0.85 25.34 15.70 3 NO 30.4742
2 N/A Motor Operated Valves (Total) 180.00 134.23 180.00 134.23 1.00 0.924 1.000 0.85 145.27 90.03 3 NO 174.728
3 N/A Control Power,120 VAC N/A 10.00 N/A 0.00 1.00 1.000 1.000 1.00 10.00 0.00 1 NO 12.0281
4 N/A Area Lighting Panel N/A 2.00 N/A 0.00 1.00 1.000 1.000 1.00 2.00 0.00 3 NO 2.40563
5 N/A Heat Tracing Panel N/A 30.00 N/A 0.00 1.00 1.000 1.000 1.00 30.00 0.00 3 NO 36.0844
Cur
rent
(A)
Stat
us Bus
Sche
me
Type
VFD
Con
tact
or S
ize
MCC-1
Total
Phase
Continuous Intermittent Stand-by
REV.
Stand-by
Electrical Load List_Gaviota.xls\Gaviota - 480 V 1 of 2Plains2017SBC-1_0002778
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.97 Amps
ELECTRICAL LOAD LIST - GAVIOTA PUMP STATION 697.9 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 641 kW 0 kW 57 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 4,160 Total 640.9 kW 0.0 kW 570.1 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-2300A Crude Oil Shipping Pump Motor 690.02 514.55 800.00 596.56 0.86 0.950 0.950 0.85 570.14 353.34 3 YES 79.127
2 M-2300B Crude Oil Shipping Pump Motor 690.02 514.55 800.00 596.56 0.86 0.950 0.950 0.85 570.14 353.34 3 YES 79.127
3 480VAC-FEEDER 480 VAC Feeder 70.78 1.000 1.000 1.00 70.78 0.00 3 NO 9.82336
MVSG-1
Total
Con
tact
or S
ize
Stat
us
Intermittent Stand-by
VFD
BusPhase
Continuous
Cur
rent
(A)
Sche
me
Type
Stand-by
REV.
Electrical Load List_Gaviota.xls\Gaviota - 4.16 kV 2 of 2Plains2017SBC-1_0002779
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.358 Amps
ELECTRICAL LOAD LIST - SISQUOC PUMP STATION 297.8 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 119 kW 137 kW 42 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 480 Total 118.6 kW 456.4 kW 422.6 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-XXXXX Crude Oil Break-Out Tank Mixer Motor 30.00 22.37 30.00 22.37 1.00 0.920 1.000 0.85 24.32 15.07 3 NO 29.248
2 M-3300 Crude Oil Booster Pump Motor 101.10 75.39 150.00 111.86 0.67 0.950 0.950 0.85 83.54 51.77
3 M-3310 Crude Oil Booster Pump Motor 101.10 75.39 150.00 111.86 0.67 0.950 0.950 0.85 83.54 51.77
4 M-3400 Crude Oil HeaterBurner Fan Motor 30.00 22.37 30.00 22.37 1.00 0.940 0.950 0.85 25.05 15.53
5 M-3410 Crude Oil HeaterBurner Fan Motor 30.00 22.37 30.00 22.37 1.00 0.940 0.950 0.85 25.05 15.53
6 M-3810 Drain Pump Motor 5.32 3.97 7.50 5.59 0.71 0.900 1.000 0.85 4.41 2.73
7 M-3910A Fire Water Pump Motor 200.03 149.16 250.00 186.43 0.80 0.950 1.000 0.85 157.02 97.31
8 M-3910B Fire Water Pump Motor 200.03 149.16 250.00 186.43 0.80 0.950 1.000 0.85 157.02 97.31
9 N/A Motor Operated Valves (Total) 375.00 279.64 375.00 279.64 1.00 0.924 1.000 0.85 302.64 187.56 3 NO 364.017
10 N/A Control Power,120 VAC N/A 10.00 N/A 0.00 1.00 1.000 1.000 1.00 10.00 0.00 1 NO 12.0281
11 N/A Area Lighting Panel N/A 5.00 N/A 0.00 1.00 1.000 1.000 1.00 5.00 0.00 3 NO 6.01407
12 N/A Heat Tracing Panel N/A 120.00 N/A 0.00 1.00 1.000 1.000 1.00 120.00 0.00 3 NO 144.338
MCC-1
Total
Phase
Continuous Intermittent Stand-by
REV.
Stand-by
Cur
rent
(A)
Stat
us Bus
Sche
me
Type
VFD
Con
tact
or S
ize
Electrical Load List_Sisquoc.xls\Sisquoc - 480 V 1 of 2Plains2017SBC-1_0002780
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.171 Amps
ELECTRICAL LOAD LIST - SISQUOC PUMP STATION 1,231.0 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 1146 kW 0 kW 85 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 4,160 Total 1,146.1 kW 0.0 kW 848.4 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-3500 Crude Oil Shipping Pump Motor 1026.75 765.65 1100.00 820.27 0.93 0.950 0.950 0.85 848.37 525.77 3 YES 117.741
2 M-3510 Crude Oil Shipping Pump Motor 1026.75 765.65 1100.00 820.27 0.93 0.950 0.950 0.85 848.37 525.77 3 YES 117.741
3 480VAC-FEEDER 480 VAC Feeder 297.76 1.000 1.000 1.00 297.76 0.00 3 NO 41.3248
BusPhase
Continuous
Cur
rent
(A)
Sche
me
Type
Stand-by
REV.
MVSG-1
Total
Con
tact
or S
ize
Stat
us
Intermittent Stand-by
VFD
Electrical Load List_Sisquoc.xls\Sisquoc - 4.16 kV 2 of 2Plains2017SBC-1_0002781
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.84 Amps
ELECTRICAL LOAD LIST - RUSSELL RANCH PUMP STATION 69.9 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 10 kW 60 kW 0 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 480 Total 10.0 kW 199.5 kW 0.0 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-4510 Drain Pump Motor 27.49 20.50 40.00 29.83 0.69 0.920 1.000 0.85 22.28 13.81 3 NO 26.7984
2 N/A Motor Operated Valves (Total) 180.00 134.23 180.00 134.23 1.00 0.924 1.000 0.85 145.27 90.03 3 NO 174.728
3 N/A Control Power,120 VAC N/A 10.00 N/A 0.00 1.00 1.000 1.000 1.00 10.00 0.00 1 NO 12.0281
4 N/A Area Lighting Panel N/A 2.00 N/A 0.00 1.00 1.000 1.000 1.00 2.00 0.00 3 NO 2.40563
5 N/A Heat Tracing Panel N/A 30.00 N/A 0.00 1.00 1.000 1.000 1.00 30.00 0.00 3 NO 36.0844
Cur
rent
(A)
Stat
us Bus
Sche
me
Type
VFD
Con
tact
or S
ize
MCC-1
Total
Phase
Continuous Intermittent Stand-by
REV.
Stand-by
Electrical Load List_Russell Ranch.xls\Russell Ranch - 480 V 1 of 2Plains2017SBC-1_0002782
Line 901 and Line 903 Replacement Project
Plains Pipeline, L.P.127 Amps
ELECTRICAL LOAD LIST - RUSSELL RANCH PUMP STATION 915.7 kWDocument No.:
Rev. No.: 1 Re-Issued for Permit Load 839 kW 0 kW 77 kW
Date: 17-Nov-17 Diversity Factor 100% 30% 10%
Volts 4,160 Total 838.8 kW 0.0 kW 769.0 kWEQUIPMENT MOTOR MOTOR LOAD MOTOR DRIVE POWER kW = A/D CONSUMED LOAD kVAr = kW.tg j
ABSORBED ABSORBED RATING RATING FACTOR EFFICIENCYEFFICIENCY FACTOREquipment LOAD LOAD at load
Tag No. Description = A/B factor C at load Continuous IntermittentA B C D factor C E F G
HP kW HP kW in decimals in decimals in decimals cos j REMARKS kW kVAr kW kVAr kW kVAr
1 M-4300A Crude Oil Shipping Pump Motor 930.65 693.98 1100.00 820.27 0.85 0.950 0.950 0.85 768.96 476.56 3 YES 106.721
2 M-4300B Crude Oil Shipping Pump Motor 930.65 693.98 1100.00 820.27 0.85 0.950 0.950 0.85 768.96 476.56 3 YES 106.721
3 480VAC-FEEDER 480 VAC Feeder 69.86 1.000 1.000 1.00 69.86 0.00 3 NO 9.69613
MVSG-1
Total
Con
tact
or S
ize
Stat
us
Intermittent Stand-by
VFD
BusPhase
Continuous
Cur
rent
(A)
Sche
me
Type
Stand-by
REV.
Electrical Load List_Russell Ranch.xls\Russell Ranch - 4.16 kV 2 of 2Plains2017SBC-1_0002783
API STANDARD 650STORAGE TANK
DATA SHEET1 3
CA
m3 (bbl) 100,467 bbl m3 (bbl)m3/h (bbl/h) m3 /h(bbl/h)
0C (0F)0C (0F)
0C (0F) 222 in. wtr. (RVP) kPa (in. water)mm(in.) mm (in.)mm(in.) 0.063 in. mm (in.)
Atm kPa (lbf/in.2)
kPa (lbf/in.2)kPa (lbf/in.2)kPa (lbf/in.2)
0C (0F)
km/h (mph)
mm/h (in./h)mm (in.)
m (ft) 48 ft m (ft)
Bakersfield
12 in./h12 in. (max)
Santa Barbara County, CA
Crude oil, sour service - see Remarks
120,560 bbl1,450 bbl/h
180 F
2" thk. mineral fiber (Mansville Micro-Lok or equivalent)250 F
Keith Johnson / Ramsgate Engineering, Inc.
Plains Pipeline, L.P.
APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER
November 17, 2017
TBD2,900 bbl/h (max)
-20 F min. / 250 F max.
Plains Pipeline, L.P.
0.125 in.0.125 in.
0.125 in.
Atmospheric
Sisquoc Pump Station
1California UBC Zone 4
100 mph
DATEBYFILE NO.PAGE OF
1. PURCHASER/AGENTADDRESSCITY PROV/STATE PC/ZIP PHONE
2. USER3. ERECTION SITE: NAME OF PLANT
LOCATION4. TANK NO. NOMINAL CAPACITY NET WORKING CAPACITY
PUMPING RATES: IN OUT6. MAXIMUM OPERATING TEMPERATURE7. PRODUCT STORED: DESIGN SPECIFIC GRAVITY AT
DESIGN METAL TEMPERATURE VAPOR PRESSURE8. CORROSION ALLOWANCE: SHELL ROOF
BOTTOM STRUCTURALS9. SHELL DESIGN: BASIC STANDARD 650 APPENDIX A APPENDIX F
DESIGN PRESSURE10. ROOF DESIGN: BASIC STANDARD 650 APPENDIX C (EXTERNAL FLOATING)
APPENDIX G (ALUMINUM DOME) APPENDIX H (INTERNAL FLOATING)FRANGIBLE ROOF JOINT? YES NO NOTE FOR SHOP TANKS
11. ROOF DESIGN INFORMATION:UNIFORM LIVE LOADSPECIAL LOADS (PROVIDE) SKETCH)INSULATION LOADMAXIMUM DESIGN ROOF TEMPERATURE AGASES IN THE VAPOR SPACE
12. EARTHQUAKE DESIGN? YES NO (APPENDIX B) ROOF TIE RODS (3,10,4,5)? YES NOSEISMIC ZONE IMPORTANCE FACTORZONE FACTOR (TABLE E-2) SITE COEFFICIENT (TABLE E-3)
13. WIND LOAD: VELOCITYPROVIDE INTERMEDIATE WIND GIRDER (3.9.7)? YES NO
14. ENVIRONMENTAL EFFECTS: MAXIMUM RAINFALLTOTAL SNOW ACCUMULATION
15. SIZE RESTRICTIONS MAXIMUM DIAMETER MAXIMUM HEIGHT16 FOUNDATION TYPE: EARTH CONCRETE RINGWALL OTHERREMARKS 1. Roof configuration: fixed external cone roof with internal floating roof (IFR)
2. Seal configuration: primary shoe with secondary wiper3. Process wetted materials of construction shall be NACE MR0175 compliant for sour service4. Ambient design conditions: 24°F to 120°F temperature range; 804 ft. ASL elevation5. Design shall comply with the requirements of SBAPCD Rule 326 - Storage of Reactive Organic Compound Liquids6. Roof vent shall route through a carbon canister (or equivalent vapor control mechanism) for additional ROC capture
0.919 140 F
Plains2017SBC-1_0002784
API STANDARD 650STORAGE TANK
DATA SHEETKeith Johnson / Ramsgate Engineering, Inc.
November 14, 2017DATEBYFILE NO.
2 3
1.2.3.
mm(in.)mm/m (in/ft)
Required Purchaser
Required
Enviroline 405HT or equivalent SP6 blast, 20 - 40 mils DFT - see Remarks
SP6 blast - see Remarks
Per API 650 Per API 650
Per API 650
SP6 blast - see Remarks
Required Required
Required
Per API 650
Per API 650
CONSTRUCTION DETAILS (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER
SP6 blast - see Remarks
134 ft 48 ft
A-516 Gr. 70A-516 Gr. 70A-516 Gr. 70
A-36
1. MANUFACTURERADDRESSCITY PROV/STATE PC/ZIP PHONE
SERIAL NO.2. FABRICATOR
ADDRESSADDRESSCITY PROV/STATE PC/ZIP PHONE
SERIAL NO.3 MATERIAL SPECIFICATIONS SHELL
ROOFBOTTOMSTRUCTURALS
4. NO. OF SHELL COURSES5. PLATE WIDTHS AND THICKNESSES (INCLUDING CORROSION ALLOWANCE), IN mm (in.)
4. 7. 5. 8. 6. 9.
6. TANK BOTTOM: PLATE THICKNESS LAP BUTT SEAMSSLOPE TO FROM CENTER
7. MINIMUM WIDTH AND THICKNESS OF BOTTOM ANNULAR PLATES (3.5) IN mm (in.):8. ROOF-TO-SHELL DETAIL (FIGURE F-1)9. INTERMEDIATE WIND GIRDER? YES NO TOP WIND GIRDER FOR USE AS WALKWAY? YES NO
10. ROOF TYPE: SUPPORTED SELF-SUPPORTED FLOATINGSLOPE OR RADIUS mm (in.)
11. ROOF PLATE: THICKNESS mm LAP BUTT JOINT12. PAINT:
SHELL-- EXTERIOR? YES NO INTERIOR? YES NOSURFACE PREPARATION
BOTTOM-- UNDERSIDE? YES NO INTERIOR? YES NOSURFACE PREPARATION
STRUCTURAL STEEL-- EXTERIOR? YES NO INTERIOR? YES NOSPECIFICATION
13. TANK BOTTOM COATING: INTERIOR? YES NO MATERIALAPPLICATION SPECIFICATION
14. INSPECTION BY: SHOP FIELD15. WELD EXAMINATION: RADIOGRAPH
SUPPLIEMENTARY LIQUID PENETRANT OR ULTRASONIC16. FILMS PROPERTY OF17. LEAK TESTING: BOTTOM ROOF
SHELL18. MILL TEST REPORTS: REQUIRED? YES NO
PLATE STRUCTURAL SHAPES19. PURCHASER'S REFERENCE DRAWING20. TANK SIZE: DIAMETER m (ft) HEIGHT m (ft)21. DATE OF STANDARD 650REMARKS Internal coating: SP6 blast, 20 - 40 mils DFT Enviroline 405HT or equivalent (tank bottom and 4 ft. up shell only)
External coating: SP6 blast, 2-3 mils DFT Carbozinc 11HS, 4-6 mils DFT Carboguard 888, 2-3 mils DFT Carbothane 134HG orequivalents (tank shell and external fixed roof)
PAGE OF
Plains2017SBC-1_0002785
API STANDARD 650STORAGE TANK
DATA SHEETKeith Johnson / Ramsgate Engineering, Inc.
November 14, 2017DATEBYFILE NO.
3 3
m2 (ft2)
ORIENTATION HEIGHT FROMMARK SIZE SGL DBL SPL A B C D E N=0 BOTTOM SERVICE
N1 16" X InletN2 18" X Outlet
N3/N4 14" X Relief InletsN5 4" X Drain InletN9 x" X Agitator
N10/N11 4" X DrainsC1/C2 2" X InstrumentsM1/M2 24" X Manways
11. ROOF NOZZLES, INCLUDING VENTING CONNECTION (SEE FIGURES 3-14 AND 3-15 AND TABLES 3-16 AND 3-17
ORIENTATION DISTANCE FROMMARK SIZE N=0 CENTER SERVICE
N6 24" X VentN7 x" X LSHHN8 x" X LITM3 24" X Blow-off
NOTE: SKETCHES AND/OR SEPARATE SHEETS MAY BE ATTACHED TO COVER SPECIAL REQUIREMENTS.
N/A
FLANGED THREADED
APPURTENANCES (TO BE COMPLETED BY MANUFACTURER AND/OR PURCHASER
Required
1 ea. 24" manway/blow-off hatch2 ea. 24" manways
N/A 90 deg. downcomer to 6 in. off bottom
FLANGED THREADED REINFORCEMENT
1. STAIRWAY STYLE: CIRCULAR STRAIGHT ANGLE TO HORIZONTAL DEGREESLADDER
2. WALKWAY: WIDTH mm (in ) LENGTH m (ft)3. DRAWOFF SUMP: STANDARD SPECIAL4. BOLTED DOOR SHEET? YES NO (APPENDIS a TANKS ONLY) RAISED FLUSH5 SCAFFOLD HITCH6. INTERNAL PIPING: SWING LINE SUCTION LINE
HEATING COIL SURFACE AREA7. ROOF DRAIN: HOSE JOINTED
SIPHON8. NO. AND SIZE OF SHELL MANHOLES9. NO. AND SIZE OF ROOF MANHOLES10. SHELL NOZZLES (SEE FIGURES 3-4B, 3-5, AND 3-7 AND TABLES 3-8, 3-9, AND 3-10):