Lecture 3-5 Instrumentation

Upload: dangliem

Post on 25-Jul-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Lecture 3-5Instrumentation

Page 2: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Requirements1. Vacuum

Mean Free PathContaminationSticking probability

UHVMaterialsStrengthStabilityPermeation

Design considerationsPumping speedVirtual leaksLeakingde-greasing

Page 3: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Vacuum pumps

DiffusionIon pumpsTurbo molecular pumpsSublimation pumpsCryo pumps

2. Sample handlingPreparationTreatment in vacuumManipulation

Page 4: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Instrument : Light source, analyser, detector

Resolution, SensitivityWidth of radiationWidth of the level Analyser resolution

FW HM

Analysers

Dispersive Retarding potential

I(Photoelectrons V, Inr, AS, D Analyser solid angleat detector)

Cross section Area of the slit

Photon Intensity

Page 5: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Transmission Fraction of electrons reaching the detector from an isotropic point source

= Useful instrument solid angle . Transmission factor

Integral of point source transmission over slit area luminority

Integral of solid angle over slit area étendue

Line width of radiation pressure broadening (Stark, van der Waals, resonance)

Doppler broadeningRecoil of atoms

Life time

Page 6: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

I(T) = 1 + E/2 [3/2 (sin2 T ) – 1] for unpolarised photonsE- asymmetry parameter

Surface Sensitivity

e-Angle

hQe-

AdsorbateI

Bulk

T

Page 7: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Other techniquesPhoto detachment EXAFS, SEXAPS, synchrotron radiation

EPMA or Electron probe x-ray micro analysis

Ion beam techniques

SIMSdynamic

staticINS (ion neutralization spectroscopy)

SNMS (sputtered neutral mass spectrometry)PIXE (particle induced x-ray emission

ISSRBSFABMS

Page 8: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

History

Photoelectric effect 1887 HertzRutherford E ray spectroscopy Before WWI

Basic XPS equation, EK = hQ - EB Originally stated by Rutherford 1914

Moseley After WWIRawlinsonRobinson E ray spectrum of elements

Anomalous lines corresponding to electron ejection due to fluorescence excitation.

Anger spectroscopy 1925

Page 9: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Steinhardt 1951

“An x-ray photoelectron spectrometer for chemical analysis”

Kai Seigbahn – Uppsala 1940’s 1967 “ESCA: Atomic, Molecular and solid state structure studied by means of Electron spectroscopy”

Acronym ESCA is due to Seigbahn

Page 10: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Early Hertz Experiment

Page 11: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 12: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

U vs. Z for a number of metals

Page 13: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Simple UPS

Page 14: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 15: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Heart of the instrument

Page 16: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

What is inside

Page 17: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

X-Ray Source

Page 18: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

X-Ray emissionspectrum

Page 19: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Detail of the spectrum

Page 20: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 21: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 22: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

X-ray source with dual filament and anode faces

Water Inlet Tube

Focusing Shields

Filament 2Filament 1

Anode Face 1 Anode Face 2

WindowX-rays

Page 23: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

UV Source

Page 24: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Synchrotron

Page 25: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

ResolutionAbsolute resolution, FWHM 'EBase width 'EB = 2 'E

Relative resolution R = 'E/E0

Represented normally, in percentage, 'E/E0 x 100

Resolving power U = 1/R = E0/'E

XPS line widths 0.7eV Mg KD, 0.85 eV Al KD, Ffr an absolute resolution of 0.2 eV, the relative resolution is 10-4 or a resolving power of 10,000.

To keep the analyser size to an optimum value, the KEs have to be retarded - pass energy.

Page 26: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

For an absolute resolution of 0.2 eV, the relative resolution is only 10-3. High absolute resolution can be achieved by retardation.

Not always advantageous.

Requirement in UPS

Page 27: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

EDC around EF in an UPS spectrum of Ag. Solid line is

the Fermi function at RT

Page 28: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Electronic structure of solids

s

p

s band

p band

Band gap

Half full

Full

Page 29: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Energy

Zero

Fermi level

Occupied

Unoccupied

Page 30: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

In a piece of metal, there are 1023 electrons.We have high quantum states for most electrons.

Probability that a given quantum state is occupied is given by the Fermi factor,

f(E) = 1/[e(E-µ)/kT + 1]

Plot of this is given here which gives a definition of Femi level.

Page 31: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

µ is chemical potential, is the energy of the level for which f(E) = ½

EF

Page 32: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

How the given energy states are occupied at a given temperature is given by Fermi-Dirac distribution.

N(E)dE = f(E)S(E)dE= S(E)dE/e(E-µ)/kT + 1]

N(E) = number of electrons per unit volume, having energy between E and E + dES(E) = number of available quantum states in this energy range.

This distribution obeys Pauli exclusion principle.Number of electrons N(E) can never be larger than the number of available statesS(E) as the denominator is always greater than one.

For states with energies well above µ, 1 in the denominator can be neglected. N(E)dE § e-(E-µ)/kT This resembles Bolzmann distribution

Page 33: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

UPS EDC at EF of Ag (15 K). Resolution, 'E is obtained by convoluting a Fermi

function with a Gaussian function

Page 34: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

AnalysersAnalysers

Page 35: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Electron beam

Sample

Retarding Field Analyser

Scan

Detector

Amplifier

Page 36: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Intensity

Retarding Voltage

Page 37: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Eo/eV = k/ln(r2/r1) mv2/r = eV

Page 38: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 39: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

ElectronGun

ElectronMultiplier

First Stage SecondState

Sample

X-Ray Source

Inner and OuterMagnetic Shields

OuterCylinder Inner

CylinderRotary Motion

Page 40: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 41: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

eǻV = E(R2/R1 – R1/R2)

Page 42: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 43: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 44: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis
Page 45: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

1. Single-Channel DetectorChannel electron multiplier:A continuousdynode surface. High count rate of 106

counts per second.

2. Multi-Channel DetectorA set of parallel detector chains or positionsensitive detectors kept at the analyserexit slit plain.

Page 46: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Semi Conducting Surface

Lead doped glass

HVe-

film

glass

106electron

Channel electron multiplier

Page 47: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Hemispherical sector electron energy analyser and control

electronics.

Page 48: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Spectrometer with X-ray monocromatisation

Page 49: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Modern instrument for UPS, XPS, AES and EELS

Page 50: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

An electron gun for beams up to 10 ke V

Page 51: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Ion gun using a Penning discharge.

Page 52: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

A liquid-metal field emission ion source

Page 53: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

A simple method of XPS imaging using a conventional HAS instrument

Page 54: Lecture 3-5 Instrumentationmmrc.caltech.edu/XPS Info/Electron Spec 2003/Elec Spec Lec 3-5... · Instrumentation. Requirements Vacuum ... EPMA or Electron probe x-ray micro analysis

Data analysis