latch-up current limiter - 3d plus · effects when exposed to radiation in a space environment. ......

2
3DPM0168-2 Latch-up protection from 0.8V to 5.5V and up to 2A Very fast switch-off time (10μs max) Very low Voltage drop across the LCL Adjustable Run & Standby threshold currents Active threshold current selection via an external signal Automatic reconnection or through ON/OFF command Adjustable delay for automatic reconnection Protection Status signal for system supervision Space Qualified Technology Radiation Hardened design TID > 50 krad(Si) SEL LET > 80MeV.cm 2 /mg SET Immune > 80MeV.cm 2 /mg Temperature Range -40°C / +115°C Compact Size and Low Weight 20-pin SOP pitch 1.27mm ITAR Free Product - Worldwide delivery guaranty Size: 15 x 15 x 12 mm Mass: 6.5 g Advanced high performance semiconductor devices can be sensitive to Single Event Latch-Up (SEL) effects when exposed to radiation in a space environment. Even though SEL is a very rare event, it can lead to device destruction and therefore must be mitigated to ensure the reliability and success of the mission. Therefore, mission critical space applications that may be susceptible to SEL, should include protection devices such as a Latch-Up current Limiter (LCL). The LCL is the best solution for power lines protection for advanced high performance electronics such as ASICs, FPGAs (Actel, Xilinx,) and memory banks in space applications: sciences and deep space missions, Earth observation, navigation, launchers and manned space vehicles. RELIABLE MINIATURIZATION TECHNOLOGIES FOR ELECTRONICS LATCH-UP CURRENT LIMITER 0.8V TO 5.5V INPUT - UP TO 2A FAST SWITCH-OFF TIME, 2 ADJUSTABLE THRESHOLDS RADIATION HARDENED DESIGN KEY FEATURES PRODUCT OVERVIEW The 3DPM0168-2 LCL Module monitors the power supply line of radiation sensitive devices and switches them off instantaneously in case of “radiation induced SEL” or high-current events in order to protect the device from over current and overheating. The LCL Module offers two adjustable threshold currents: to control device Run & Standby currents and two operating modes: Automatic reconnection with adjustable delay or reconnection through ON/OFF command. Featuring specific radiation effect mitigation techniques and utilizing space design derating rules, the 3DPM0168-2 Latch-up Current Limiter is an ITAR Free product and features a SEL/SEE LETth of 80 MeV.cm 2 /mg and a TID of 50krad (Si).

Upload: nguyenduong

Post on 02-May-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LATCH-UP CURRENT LIMITER - 3D PLUS · effects when exposed to radiation in a space environment. ... as ASICs, FPGAs (Actel, ... Featuring specific radiation effect mitigation techniques

RELIABLE MINIATURIZATION TECHNOLOGIES FOR ELECTRONICS

3 D P M 0 1 6 8 - 2

Latch-up protection from 0.8V to 5.5V and up to 2A

Very fast switch-off time (10µs max)

Very low Voltage drop across the LCL

Adjustable Run & Standby threshold currents

Active threshold current selection via an external signal

Automatic reconnection or through ON/OFF command

Adjustable delay for automatic reconnection

Protection Status signal for system supervision

Space Qualified Technology

Radiation Hardened designTID > 50 krad(Si)

SEL LET > 80MeV.cm2/mg

SET Immune > 80MeV.cm2/mg

Temperature Range -40°C / +115°C

Compact Size and Low Weight

20-pin SOP pitch 1.27mm

ITAR Free Product - Worldwide delivery guaranty

Size: 15 x 15 x 12 mm

Mass: 6.5 g

Advanced high performance semiconductor devices can be sensitive to Single Event Latch-Up (SEL)effects when exposed to radiation in a space environment. Even though SEL is a very rare event, it canlead to device destruction and therefore must be mitigated to ensure the reliability and success of themission. Therefore, mission critical space applications that may be susceptible to SEL, should includeprotection devices such as a Latch-Up current Limiter (LCL).

The LCL is the best solution for power lines protection for advanced high performance electronics suchas ASICs, FPGAs (Actel, Xilinx,…) and memory banks in space applications: sciences and deep spacemissions, Earth observation, navigation, launchers and manned space vehicles.

RELIABLE MINIATURIZATION TECHNOLOGIES FOR ELECTRONICS

LATCH-UP CURRENT LIMITER0 . 8 V T O 5 . 5 V I N P U T - U P T O 2 AF A S T S W I T C H - O F F T I M E , 2 A D J U S TA B L E T H R E S H O L D S R A D I AT I O N H A R D E N E D D E S I G N

K E Y F E AT U R E S

P R O D U C T O V E R V I E W

The 3DPM0168-2 LCL Module monitors the powersupply line of radiation sensitive devices and switchesthem off instantaneously in case of “radiation inducedSEL” or high-current events in order to protect thedevice from over current and overheating.

The LCL Module offers two adjustable thresholdcurrents: to control device Run & Standby currents andtwo operating modes: Automatic reconnection withadjustable delay or reconnection through ON/OFFcommand.

Featuring specific radiation effect mitigation techniquesand utilizing space design derating rules, the3DPM0168-2 Latch-up Current Limiter is an ITAR Freeproduct and features a SEL/SEE LETth of 80MeV.cm2/mg and a TID of 50krad (Si).

Page 2: LATCH-UP CURRENT LIMITER - 3D PLUS · effects when exposed to radiation in a space environment. ... as ASICs, FPGAs (Actel, ... Featuring specific radiation effect mitigation techniques

R E L I A B L E M I N I A T U R I Z A T I O NT E C H N O L O G I E S F O R E L E C T R O N I C S

w w w . 3 d - p lu s . c o m

P R O D U C T P E R F O R M AN C E S

PIN DESCRIPTION

Vin Input voltage used to power the LCL output load

Vout Protected voltage provided to the sensitive load

GND Ground pin

ON/OFF External command to switch ON (high level) or OFF (low level) the LCL

Prot_Status Digital output signal which reflects the current LCL status (Low=LCL not tripped, High=LCL tripped)

Run/Stb External input command to select the RUN protection current (high level) or the STANDBY protection current (low level)

VauxAuxiliary supply used to power the internal control circuit. Minimum Vaux voltage is 3.3V. When above 5.5V,a serial resistance must be inserted in series with Vaux pin. Can be connected to Vin when Vin is between 3.3V and 5.5V

Lim_Run Used to adjust the RUN protection level. Adjustment performed by connecting an external resistor between the pin and Lim_Stb pin

Lim_StbUsed to adjust the STANDBY protection level. Adjustment performed by connecting an external resistor between this pin and ground

Adj_RestartUsed to adjust the automatic reconnection delay. Adjustment performed by connecting an external capacitor betweenthis pin and ground. Use a short to inhibit the automatic reconnection mode

PARAMETER SYMBOL MIN TYP MAX UNIT

VOLTAGE & CURRENT

Input Voltage Vin 0.8 5.5 V

Output Current Iout 2000 mA

Voltage drop @ 1A Vdrop 95 110 mV

Capacitive load Cload 10 µF

Auxiliary Supply Vaux 3.2 5.5 V

COMMANDS

ON Voltage threshold (Vaux=3.3V) Von 2.32 V

OFF Voltage threshold (Vaux=3.3V) Voff 1.05 V

Hysteresis (Vaux=3.3V) Hys 0.53 0.96 V

VOLTAGE & CURRENT

Standby threshold Current Ith1 100 Ith2 mA

Run threshold Current Ith2 Ith1 2000 mA

Delay for automatic reconnection Tdelay 0.5 300 ms

Current threshold accuracy (Ith=1A) Iacc -8 8 %

Timing delay accuracy Tacc -25 25 %

Output Slope (dV/dT at switch ON) SwonT 2 16 mV/µs

Switch OFF time SwoffT 10 µs

www.3d-plus.com

TEMPERATURE RANGES

C : Commercial (0°C to 70°C)

I : Industrial (-40°C to +85°C)

S : Specific (-40°C to +115°C)

ORDERING INFORMATION

QUALITY GRADES

N : Commercial

B : Industrial

S : Space

P I N D E S C R I P T I O N

Part Number – X X – X00X

Quality Grade

Temperature Range

Options

PAC K AG E

CO

PY

RIG

HT

3D

PL

US

-JU

NE

2017