large projects require strong teams · vessels for various industries including composite...
TRANSCRIPT
High Technology Sterilization Systems For Medical Waste Sterilization
INDEX
ABOUT US
WHAT IS THE STERILIZATION?
PRE-SHREDDINGSYSTEMS
POST-SHREDDINGSYSTEMS
PRE SHREDDING SYSTEMS FOR HOSPITALS
CERTIFICATIONS
REFERENCES
SAMPLE LAYOUTS
TROLLEY
AUTOCLAVE
CONTROL PANEL
COMPRESSOR STEAM GENERATOR
7000
5000
3000
5
8
12
14
10
20
16
18
Akarmak, founded in 1990, manufactures autoclaves, machines and pressure vessels for various industries including Composite Materials, Glass, Tire Retreading - Rubber Vulcanization, Building Materials, and Medical Waste Sterilization.
Medical waste sterilization (MWS) systems are manufactured in our state-of-the-art manufacturing facilities in the city of Eskisehir, with close proximity to major cities and ports. From the customer requirement acquisition stage to design, manufacturing, test, delivery and on-site commissioning,
Akarmak is capable of providing turn-key and boutique solutions for every customer need. Akarmak is the only company in the world that has technologies for both pre-shredded and post-shredded MWS systems.
The systems are designed using advanced design tools and software meeting the highest safety and quality standards. We approach every project as unique and custom-made, and can handle customer specific requests. The MWS Systems are manufactured with limited reliance on outside suppliers and are carried out by an experienced, highly trained and certified work force and technical staff.
Akarmak has the following certifications including those for autoclave and pressure vessel manufacturing:
- Pressure Equipment Directive 97/23/EC (PED)- Simple Pressure Vessels Directive 2009/105/EC (SPVD)- ASME SEC VIII Div. 1- GOST - R- DIN EN 15085-2 CL 1- DIN EN ISO 3834-2
Other certificates that may be required by different countries and jurisdictions To certify our autoclaves, we work with internationally well-known certificate agencies such as Bureau Veritas, TUV, Hartford Steam Boilers.
Thank you for your interest in our company and our products. We look forward to realizing successful projects with you, and enhancing your value chain with our high quality products.
For more information, please visit us at; www.akarmak.com.trwww.autoclave.com.tr
- State of the art machinery manufacturing facility- Professional management team with experience and knowledge- Highly-skilled workforce (incl. certified welders)- High machining capacity and advanced design capabilities- Conveniently located in the hub city of Eskisehir (close to ports and major cities such as Istanbul, Ankara, Bursa)- ISO 9001 – 2008 certified and providing CE Certification with its own equipment- Well executed future growth plans- Export and growth oriented international company- High degree of flexibility and access to numerous subcontractor companies allow Akar to manage high-volume projects
QUICK FACTS
ABOUT US
LARGE PROJECTSREQUIRE STRONG TEAMS
5
6 7
Eskisehir, Turkey Conveniently located close to ports and major cities.
FACTORY27.000 m2 factory space in Eskişehir
Industrial Zone
QUALITYISO 9001-2008 certified with advanced
engineering capabilities
Professional management with well executed future growth plans
LOCATION
ASME, CE, GOST-RDIN EN 15085-2 CL 1, DIN EN ISO 3834-2
An autoclave is a commonly used method for heat sterilization. Autoclaves normally use steam heated to 121–134 °C (250–273 °F). To achieve sterility, a holding time of at least 15 minutes at 121 °C (250 °F) or 3 minutes at 134 °C (273 °F) is required. Additional sterilizing time is usually re-quired for liquids and instruments packed in lay-ers of cloth, as they may take longer to reach the required temperature (not necessary in machines that grind the contents prior to sterilization). Fol-lowing sterilization, liquids in a pressurized au-toclave must be cooled slowly to avoid boiling over when the pressure is released. Modern auto-claves avoid this problem by gradually depressing the sterilization chamber and allowing liquids to evaporate under a negative pressure, while cool-ing the contents. Proper autoclave treatment will eliminate all fungi, bacteria, viruses and also bac-terial spores, which can be quite resistant. It will not necessarily eliminate all prions.
For prion elimination, various recommendations state 121–132 °C (250–270 °F) for 60 minutes or 134 °C (273 °F) for at least 18 minutes. The prion that causes the disease scrapie (strain 263K) is inactivated relatively quickly by such sterilization procedures; however, other strains of scrapie, as well as strains of CJD and BSE are more resistant. For a significant margin of safety, cleaning should reduce infectivity by 4 logs, and the sterilization method should reduce it a further 5 logs. To en-sure the autoclaving process is able to cause sterilization, most autoclaves have meters and charts that record or display pertinent infor-
mation such as temperature and pressure as a function of time. Indicator tape is often placed on packages of products prior to autoclaving. A chemical in the tape will change color when the appropriate conditions have been met. Some types of packaging have built-in indicators on them. Biological indicators (“bioindicators”) can also be used to independently confirm auto-clave performance. Simple bioindicator devices are commercially available based on microbial spores. For effective sterilization, steam needs to penetrate the autoclave load uniformly, so an autoclave must not be overcrowded, and the lids of bottles and containers must be left ajar. Alter-natively steam penetration can be achieved by shredding the waste in some autoclave models that also render the end product unrecognizable. During the initial heating of the chamber, residual air must be removed. Indicators should be placed in the most difficult places for the steam to reach to ensure that steam actually penetrates there. For autoclaving, as for all disinfection or sterili-zation methods, cleaning is critical. Extraneous biological matter or grime may shield organisms from the property intended to kill them, whether it physical or chemical. Cleaning can also remove a large number of organisms. Proper cleaning can be achieved by physical scrubbing. This should be done with detergent and warm water to get the best results. When cleaning instruments or uten-sils with organic matter, cool water must be used because warm or hot water may cause organic debris to coagulate. Treatment with ultrasound or pulsed air can also be used to remove debris.
Source:Wikipedia
8 9
AKR50L AKR100LSterilization Capacities (kg/h) 50 100
Process MethodFull Automatic (Loading is manual),
Pre-shredding, Pressured,Steam Sterilization
Pressure Vessel and Shredder Hopper Meterials
Stainless-steel AISI 316 L
Pressure Vessel and CE Certification Bureau Veritas
Total Weights(exept steam boiler and compressor)(kg)
2.500 3.000
Feeding Unit’s Volume (lt) 150 150
Sterilization Vessel’s Volume (lt) 250 450
Waste Feeding System Manual loading with waste bags
Feeding, Discharging Door System’s Opennig/Closing, Locking/Unlocking
Pneumatic Pneumatic
Total Design Power(Excluding Steam Generator and Compressor) (kw)
20 20
Dimensions (Width x Length x Height) (mm) 2000x1500x3000 2500x2000x3000
Shredder’s Electric Motor Power 1x7,5KW & 1x5KW 1x7,5KW & 1x10KW
Feeding, Discharging Door Design Method Bayonet Bayonet
Automatic Weight System - -
Shredder Type : Double Axle,Separated gearbox for each axle Programmable Auto Reverse Control System for Shredder Waste Mixing and Discharging System :Archimedes Screw (Hardox 500)
Sterilization Temperature : 135-140 C
Sterilization Pressure : 3-5 bar (Programmable)
Vacuuming : Venturi System or Vacuum Pump
PLC & Automation System :Siemens S7/300, Touch Panel, Simatic Software, Programme Uploads and Long DistanceRemote System with Internet Connection Monitorization, Report Data Saving:Coloured Display, Turkish or English Menu
Data Save and Print-out System for Reporting 2” Double Condensate Discharge CE Certified
MEDICAL WASTE STERILIZATION SYSTEM
WITH PRE SHREDDED AUTOCLAVE METHODS
Two different capacity sterilization systems for specific customer needs
Manual loading into hopper with small bags.
High quality materials.
Full automatic and advanced automation control system with pressured direct steam sterilization
Advanced reporting and monitoring features
High standard of sterilization meeting requirements by regulations
Turnkey solutions including shredders, autoclave trolleys, steam generators, air compressor systems
Special gasket system for perfect vacuum and pressure conditions
Multiple safety control devices and built with highest safety standards
Design and manufacturing with international standards including CE, ASME, GOST-R
TECHNICAL FEATURES
PRE SHREDDINGSYSTEMSFOR HOSPITALS
1
2
3
4
Waste loading Manual loading with small bags.
Shredding Automation control with current when system locked. Autoreversing screw steps can be programmed for different capacity models.
SterilizationFull automatic mode during vacuuming, steam charging and depressurising .Automatic water discharging.
Waste DischargingFront door will be opened and waste discharge will be started automaticly with screw.
10 11
TECHNICAL FEATURES
AKR300L AKR500L AKR750LSterilization Capacities (kg/h) 300 500 750
Prosess MethodFull Automatic, Pre-shredding,Pressured, Steam Sterilization
Pressure Vessel and Shredder Hopper Meterials
Stainless-steel AISI 316 L
Pressure Vessel and CE Certification Bureau Veritas
Total Weights with Steel Structures(exept steam boiler and compressor)(kg)
7.500 10.000 12.500
Feeding Unit’s Volume (lt) 1.500 1.500 1.500
Sterilization Vessel’s Volume (lt) 1.000 1.500 2.000
Waste Feeding SystemFull Automatic Including Lifter,
Container Feeding System
Feeding, Discharging Door System’s Opennig/Closing, Locking/Unlocking
Hydraulic Hydraulic Hydraulic
Total Design Power(Excluding Steam Generator and Compressor) (kw)
60 60 60
Dimensions (Width x Length x Height) (mm) 4700x4500x6500 4700x5000x6500 4700x6000x6500
Shredder’s Electric Motor Power 1x22KW & 1x15KW 1x22KW & 1x15KW 1x22KW & 1x15KW
Feeding, Discharging Door Design Method Bayonet Bayonet Bayonet
Automatic Weight System a a aShredder Type : Double Axle,Separated gearbox for each axle a a aProgrammable Auto Reverse Control System for Shredder a a aWaste Mixing and Discharging System :Archimedes Screw (Hardox 500) a a a
Sterilization Temperature : 135-140 C a a a
Sterilization Pressure : 3-5 bar (Programmable) a a a
Vacuuming : Venturi System or Vacuum Pump a a aPLC & Automation System :Siemens S7/300, Touch Panel, Simatic Software a a aProgramme Uploads and Long DistanceRemote System with Internet Connection a a aMonitorization, Report Data Saving:Coloured Display, Turkish or English Menu a a a
Data Save and Print-out System for Reporting a a a2” Double Condensate Discharge a a aCE Certified a a a
PRE SHREDDINGSYSTEMS
MEDICAL WASTE STERILIZATION SYSTEM
WITH PRE SHREDDED AUTOCLAVE METHODS
Medical waste sterilization system with pre shredded autoclave methods
Hopper,shredder and sterilization units are integrated
Easy installation and disassembling
Manufactured according to pressured vessel standards
Compact design with its own crane
High quality materials
Various hourly capacity sterilization systems based on specific customer needs
Full automatic and advanced automation control system with pressured direct steam penetration
Advanced reporting and monitoring features
High standard of sterilization meeting requirements by regulations
Turnkey solutions including shredders, steam generators, air compressor systems
Special gasket system for perfect vacuum and pressure conditions for both doors
Multiple safety control devices and built with highest safety standards
Design and manufacturing with international standards including CE, ASME, GOST-R
1
2
3
4
Waste loading With automatic lifter.Number of cars can be programmed for various capacity during loads.
Shredding Automation control with current when system locked.Autoreversing screw steps can be programmed for different capacity models.
SterilizationFull automatic mode during vacuuming, steam charging and depressurising. Automatic water discharging.
Waste DischargingFront door will be opened and waste discharge will be started automaticly with screw.
12 13
TECHNICAL FEATURESAKR500A AKR1000A AKR1500A
Sterilization Capacities (kg/h) 500 1.000 1.500
Prosess Method Full Automatic, Post-shredding, Pressured, Steam Sterilization
Autoclave Material P295GH
Pressure Vessel and CE Certications Bureau Veritas
Total Weights (Autoclave with shredding system,-except steam boiler and compressor) (kg)
21.500 23.500 25.000
Sterilization Vessel’s Volume (lt) 14.000 20.000 26.000
Waste Feeding System into Shredder’s hopper Full Automatic Including Lifter, Covered with transparent fences, Container Feeding System
Autoclave Door System Full Automatic, Hydraulic closing/opening, hydraulic locking/unlocking
Total Design Power(Excluding Steam Generator and Compressor)
70 kW
Autoclave Inner Dimensions(Width x Length x Height) (mm)
Ø2.000 x 4.000 Ø2.000 x 6.500 Ø2.000 x 8.500
Autoclave Trolley (mm) 1200x1200x1200
Autoclave Car Material AISI 316 L
Autoclave Car Quantity for Cycle 3 5 7
Door Designation Bayonet Bayonet Bayonet
Shredding System Feeding Hopper Capacity (lt) 2.000 2.000 2.000
Shredder Gearbox Power 1 x 22 KW & 1 x 30 KW 1 x 22 KW & 1 x 30 KW 1 x 22 KW & 1 x 30 KW
Shredding System Waste Loading Full Automatic, Lifter, Manual Car Loading
Compressor Capacities (bar - m3/min) 8 - 2,5
Steam Boiler Capacities (kg/h) 1.500 2.000 2.500
Shredding System Space Dimensions (mm) 5000 x 5000 x 6000 6500 x 6200 x 6500
Optimum Building Area Needs (mm) 15.000 x 15.000 x 8.000 18.000 x 15.000 x 8.000 20.000 x 15.000 x 8.000
Shredded Waste Size (length - width) (mm) 100 x 30
Automatic Lifting for AutoclaveLoading and Weight Control a a a
Shredder Type : Double Axle,Separated gearbox for each axle a a a
Programmable Auto ReverseControl System for Shredder a a a
Sterilization Temperature : 140-155 C a a a
Sterilization Pressure : 3-5 bar (Programmable) a a a
Vacuuming : Water Jacket Vacuum Pump a a a
PLC & Automation System :Siemens S7/300, Touch Panel, Simatic Software, a a a
Programme Uploads and Long DistanceRemote System with Internet Connection a a a
Monitorization, Report Data Saving:Coloured Display, Turkish or English Menu a a a
Data Save and Print-out System for Reporting a a a
2” Double Condensate Discharge a a a
CE Certified a a a
MEDICAL WASTE STERILIZATION SYSTEM
WITH POST SHREDDED AUTOCLAVE METHODS
Medical waste sterilization system with post shredded autoclave methods
High quality materials
Various hourly capacity sterilization systems based on specific customer needs
Full automatic and advanced automation control system with pressured direct steam sterilization in autoclave
Automatic shredding after loading into shredder’s lifter
Advanced reporting and monitoring features
High standard of sterilization meeting requirements by regulations
Turnkey solutions including shredders, autoclave trolleys, steam generators, air compressor systems
Special gasket system for perfect vacuum and pressure conditions
Multiple safety control devices and built with highest safety standards
Design and manufacturing with international standards including CE, ASME, GOST-R
POST SHREDDINGSYSTEMS
1
2
3
4
Waste loading Manual loading with stainless trolleys into autoclave.Automatic weighing in front of autoclave.Automatic sterilization process
Car loading Automatic lifting with safety
Waste ChargingAutomaticly lifting into hopper. Hopper safety door is opened
ShreddingAutomatic shredding process and hopper door is closed.Direct loading into truck
14 15
Environment-conscious
Akar Makina has set up many medical waste sterilization systems in Turkey and abroad, and exports such systems to regions like Europe, Africa and the Middle East, and provides high-tech system projects with pre and post shredded medical waste sterilization systems.
protecting the future starting today
& environment-friendly manufacturing,
İNTE A.Ş.
İNTE A.Ş.
KENT ÇEVRE
MİROĞLU TEMİZLİK A.Ş.
MİROĞLU TEMİZLİK A.Ş.
ROHAN TEMİZLİK LTD. ŞTİ.
AKTAŞ TEMİZLİK LTD. ŞTİ.
BİBERCİ İNŞAAT ŞİRKETLER GRUBU
ÇEVSAN ATIK GERİ DÖNÜŞÜM LTD. ŞTİ.
HDN EQUIPMENT & TECHNOLOGIES CO. LTD
CAMPAK GROUP
MERSİN/TURKEY
TOKAT/TURKEY
MALATYA/TURKEY
AFYONKARAHİSAR/TURKEY
MANİSA/TURKEY
VAN/TURKEY
ŞANLIURFA/TURKEY
KONYA/TURKEY
DİYARBAKIR/TURKEY
VIETNAM
ACCRA/GHANA TO EX
PORT
S OV
ER20
COU
NTRI
ESAFYON/TURKEY
MERSİN/TURKEY
TOKAT/TURKEY
AFYON/TURKEY
DİYARBAKIR/TURKEY
ŞANLIURFA/TURKEY
MANİSA/TURKEY
VAN/TURKEY
VIETNAM
KONYA/TURKEY
MALATYA/TURKEY
ACCRA/GHANA
16 17
CONDENSATE TANK
COLD ROOM
STEAM BOILER
COMPRESSOR
1256
1342
15300
29000
7800
6650
9900
4500
OFFICE
CONTAINERWASHING ROOM
WATERTREATMENT
8270
7000
TROLLEY
AUTOCLAVE
CONTROL PANEL
COMPRESSOR STEAM GENERATOR
7000
5000
3000
CO
ND
EN
SA
TE T
AN
K
C
OLD
RO
OM
STE
AM
BO
ILE
R
OFF
ICE
-1
CO
MPR
ESSO
R
9150
1256
1342
25000
3300
0
6750 8700 8700
10000 65007640
OFF
ICE
-2
OFF
ICE
-3
3614
C
ON
TAIN
ER
WA
SH
ING
RO
OM
W
ATE
RTR
EA
TME
NT
PRESHREDDINGSYSTEMSFOR HOSPITALS
AKR 50L Sample Layout
AKR 300L Sample Layout
AKR 1000ASample Layout
POSTSHREDDINGSYSTEMS
PRESHREDDINGSYSTEMS
1/2"
CHIMNEY
STEAMGENERATOR
AIR TANK 1000 lt
COMPRESSOR
WATER
TREATMENT
STEAM EXITWATER DISCHARGE
1"
1 1/4"1 1/4"
ELE
KTR
ICA
L
PO
WE
R
SU
PP
LY
DN32 PN16 TYPE C
DN
25 P
N16
TY
PE
C
DN
32 P
N16
TY
PE
C
CO
NTR
OL
PA
NE
L
W
ATE
R S
UP
PLY
OUT SIDE
18 19