    1 Connect the computer to theMonitor Port of the Monitor Board

    with a serial cable.

    2 Open the Repeater Test software

    on the computer.

    3 Select the correct COM Number.

  • 7/29/2019 Lacal Test Manual

    3/25

    3

    PLL Setup (Generally, we need not to change the default values which have

    been set correctly according to the specified repeater by the testing engineers

    in the Guanri manufacture center.):

    Operation Steps:

    Repeater Operation-PLL Set (the password is: hwthwt)

  • 7/29/2019 Lacal Test Manual

    4/25

    4

    Notes: Firstly, we must select the correct repeater type. In thewindow above,64 stands for the 200KHz frequency adjusting step.

  • 7/29/2019 Lacal Test Manual

    5/25

    5

    5 Parameters Setup

    Repeater Operation-Parameters Setup

  • 7/29/2019 Lacal Test Manual

    6/25

    6

    Then display this dialog

  • 7/29/2019 Lacal Test Manual

    7/25

    7

    Frequency Parameters Setup

    Firstly, select the correct repeater type in the selective frame(displayed in blue in the window above).Secondly, set specified working channels(or working channels and shift

    channels).

  • 7/29/2019 Lacal Test Manual

    8/25

    8

    UL/DL PA switch states and Attenuation Setup

    Click on Other Parameters Setup, the window below will appear.

  • 7/29/2019 Lacal Test Manual

    9/25

    9

    Communications Parameters Setup

    Click on Communications Parameters. See the window below.Set correct Numbers of the center station and select the correct

    communication mode.

  • 7/29/2019 Lacal Test Manual

    10/25

    10

    display the Output powers

    Firstly, check the real-time value of the output power:

  • 7/29/2019 Lacal Test Manual

    11/25

    11

    So the window below will be displayed on the computer

  • 7/29/2019 Lacal Test Manual

    12/25

    12

    Then the window below will be displayed on the computer

    From the window, we can get all the values and the states displayed:

    Especially DL/UL PA Power show we the signal output power of the repeater. If the output

    power is not ideal, we can set the UL and UL Attenuation whose maximum values both are 31 dB

    to change the output power. Take note that if you adjust the DL Attenuation, you need to adjust

    the UL Attenuation too for keeping the balance.

  • 7/29/2019 Lacal Test Manual

    13/25

    13

    Check the alarm states

  • 7/29/2019 Lacal Test Manual

    14/25

    14

    Firstly, enable all alarms switch

  • 7/29/2019 Lacal Test Manual

    15/25

    15

    Then, check the alarms states

    Operations: Parameters Query-Alarms Query

  • 7/29/2019 Lacal Test Manual

    16/25

    16

    Then the alarm status window display

  • 7/29/2019 Lacal Test Manual

    17/25

    17

    And we can adjust some alarm thresholds to change some alarm states.

    Operations: Repeater Operation-Parameters Setup-Alarm Threshold Setup

  • 7/29/2019 Lacal Test Manual

    18/25

    18

    We can Query the real-time parameters of the repeater

    Firstly select Parameters Query Real_time Parameters Query

  • 7/29/2019 Lacal Test Manual

    19/25

    19

    Then display the Real-time Parameters Query window

  • 7/29/2019 Lacal Test Manual

    20/25

    20

    And we can adjust some alarm thresholds to change some alarm states.

    Operations: Repeater Operation-Parameters Setup-Alarm Threshold

    Setup

  • 7/29/2019 Lacal Test Manual

    21/25

    21

    Adjust the analog values adjustment to change the values

    displayed in the following window

  • 7/29/2019 Lacal Test Manual

    22/25

    22

    Adjust the values adjustment

    Operations: Repeater Operation-Analogs Value Adjusting

    Notes: Forward Adjust

    means making the

    relating values

    becoming bigger just in

    displaying, but it cant

    change the realworking values. And

    Reverse Adjust means

    making the relating

    values less in displaying.

  • 7/29/2019 Lacal Test Manual

    23/25

    23

    There are some information which has been set as

    default of the repeater in the software, we need not

    to change them because they do not effect the

    working states of the repeater.

    After all the parameters have been set correctly, the

    repeater can work normally.

  • 7/29/2019 Lacal Test Manual

    24/25

    24

    ServiceYour satisfaction is our priority. Offering a quick and

    effective technical support, we always put the customer first.

    Please dont hesitate to contact us by the following ways if you

    have any questions.

    Guanri Telecom-Tech(Shenzhen) Co., Ltd.Address: 3/F, Building R3-B, High-Tech Industrial Park,

    Shenzhen, P.R.C.

    Post code: 518057

    Tel.: 86-755-26712354, 26520688

    Fax: 86-755-26548582

    E-mail: [email protected]

    Website: http://www.guanri.com.cn

    mailto:[email protected]://www.guanri.com.cn/http://www.guanri.com.cn/mailto:[email protected]
  • 7/29/2019 Lacal Test Manual

    25/25

    25

    Thank You!