kak-s tension load cell - captronic-sensor.com · kak-s tension load cell applications features •...
TRANSCRIPT
![Page 1: KAK-S Tension Load Cell - captronic-sensor.com · KAK-S Tension Load Cell Applications Features • Rated load 2t to 50t • Made of stainless steel • Environmental protection IP](https://reader031.vdocuments.mx/reader031/viewer/2022021723/5cdf4e1688c993d22e8bd337/html5/thumbnails/1.jpg)
KAK-STension Load Cell
Applications
Features
• Rated load 2t to 50t• Made of stainless steel • Environmental protection IP 65
Dimensions
• Direct load measuring in wire ropes• Assembly technology• Anchoring
G
H
F
E
A B
C
D
I
Rated Load A (mm) B (mm) C (mm) D (mm) E (mm) F (mm) G (mm) H (mm) I (mm) Weight
2t3t6t
10t15t20t50t
98125180290350400450
6885
120200240250290
30406080
100120150
15.220.130.240.350.360.370.3
1016.518.522232528
68
1022232528
(35)263347474747
295378
123.5147172197
7778888
approx. 0.3kgapprox. 0.5kgapprox. 2.3kgapprox. 3.3kgapprox. 5kgapprox. 8kgapprox. 9.5kg
Photo: KAK-S/6t
Masterforce® KAK-S/6t with TEDS-Msensor recognition and instrument
Options
• Integrated amplifier (>10t)• External amplifier • Connector with sensor recognition for directly measuring load with masterforce® instrument
Drawing KAK-S/6t
![Page 2: KAK-S Tension Load Cell - captronic-sensor.com · KAK-S Tension Load Cell Applications Features • Rated load 2t to 50t • Made of stainless steel • Environmental protection IP](https://reader031.vdocuments.mx/reader031/viewer/2022021723/5cdf4e1688c993d22e8bd337/html5/thumbnails/2.jpg)
A.S.T. – Angewandte System Technik GmbH. Mess- und Regeltechnik • Marschnerstraße 26 • 01307 Dresden • Germany • Tel +49 (0)351/ 44 55 491 • www.ast.deData sheet KAK-S • Subject to technical changes • 03/2013
Accuracy Class % Fnom 1 1 With Integrated Amplifier
Rated (nominal) force (Fnom)Maximum operating force (FG)Breaking force (FB)
t% Fnom
% Fnom
2/ 3/ 6/ 10/ 15/ 20/ 50150
>300
10/ 15/ 20/ 50150
>300
Rated characteristic value (Cnom)Zero signal toleranceReference excitation voltage (Uref)Operating range of excitation voltage (BUG)Input resistance (typ.) (Re)Output resistance (Ra)Insulation resistance (Ris)
mV/V%Vref
VDCΩΩΩ
1.5 ± 0.2≤ 110
0.5 ... 12380 ± 30 352 ± 1.5 > 5 x 109
Supply voltageInput currentCurrent output signalVoltage output signal (max. load 5mA)Maximum resistance
VDCmA
VmAΩ
19...2835 (at 24V)
0 ... 100/4 ... 20
300
11...1520 (at 12V)
0 ... 50/4 ... 20
100
Relative linearity error (dlin)Relative reversibilty error (v)Temperature effect on zero signal (TK0)Temperature effect on characteristic value (TKc) Relative creep over 30 minutes (dcr. F+E)
%%
% / 10K% / 10K
%
0.50.50.50.2≤ 1
0.50.50.50.2≤ 1
Reference temperature (Tref)Rated temperature range (BT, nom)Operating temperature range (BT, G)Storage temperature range (BT, S)Environmental protection (EN 60529)
oCoCoCoC
+23-25 ... +60-30 ... +70-40 ... +70
IP 65
+23-25 ... +60-30 ... +70-40 ... +70
IP 65All data according to VDI/VDE/DKD 2638
Specifications
Order ExampleType Code Description
KAK-S/10t/1/24V/0...10V Load cell 10t with 1% accuracy Output signal (with integrated amplifier) Supply voltage (with integrated amplifier) Accuracy class Nominal load Model
Wiring CodeCable length 3m
Compressive load is positive signal
Type Code Description
Plug and cable XKC 041XKC 044.01XKC 046.03 XKC 071XKC 072
6 pin plug instead of free cable ends for connecting the display unit AE 7035-pin flange plug mounted to sensor bodyConnecting cable 5m for XKC 044.016 pin plug connected to sensor cable incl. TEDS sensor recognition function6 pin plug connected to sensor cable incl. TEDS-M function for use in masterforce® systems
Accessoires/ Options
(0V and PRG to be connected by the customer) With integrated amplifier
supply voltage +
shield
signal +
(SHI)
(OUT)
ground /signal -programminginterface
(0V)
(PRG)
brown
black
green
yellow
white
(UB)
(0V und PRG to be connected by customer)with integrated amplifier