    WALKair V3.1

    ITMN

    Commissioning Guide

    P/N 110503-00 D REV 1.0

    January 2000

  • 8/10/2019 ITMN Commissioning Guide

    2/56

    2000 Floware Wireless Systems Ltd. All rights reserved.

    Floware Wireless Systems Ltd. reserves the right to alter the equipment specifications and descriptions in thispublication without prior notice. No part of this publication shall be deemed to be part of any contract or warrantyunless specifically incorporated by reference into such contract or warranty.

    The information contained herein is merely descriptive in nature, and does not constitute a binding offer for the sale ofthe product described herein.

  • 8/10/2019 ITMN Commissioning Guide

    3/56

    TABLE OF CONTENTS

    P/N 110503-00 D REV 1.0 Page i

    TABLE OF CONTENTS

    TABLE OF CONTENTS ...........................................................................................i

    List of Figures .......................................................................................................iii

    List of Tables.........................................................................................................iv

    1 Introduction ..............................................................................................1-11.1 Safety Precautions ........................................................................1-1

    2 Overview of the System Commissioning Process................................2-1

    2.1 BS-BU Commissioning..................................................................2-33 Getting Started .........................................................................................3-1

    3.1 Step 1: Connecting the LCI Terminal to the BU ............................3-23.2 Requirements ................................................................................3-23.3 RS-232 Serial Cable......................................................................3-2

    3.3.1 LCI Software Settings................................................................3-53.3.2 Global Navigation Key Symbol Commands ..............................3-5

    3.4 Step 2: Setting Network Parameters .............................................3-83.4.1 Setting BU IP Parameters .........................................................3-83.4.2 Adding Authorized Manager Stations......................................3-10

    3.5 Step 3: Setting the Radio Parameters .........................................3-11

    3.6 Step 4 Setting the Administrative Parameters.............................3-143.6.1 TS Administrative Parameters.................................................3-143.6.2 Registering a New Terminal....................................................3-143.6.3 BS Administrative Parameters ................................................3-15

    3.7 Step 5 Setting the BS/TS Telecom Parameters ..........................3-183.7.1 Changing the Configured Port Type........................................3-193.7.2 E1 Telecom Port Configuration ...............................................3-203.7.3 Editing a V.35/X.21 Telecom Port ...........................................3-22

    3.8 Step 6 Defining Services .............................................................3-24

    4 Leased Line Service Management..........................................................4-14.1 Adding Leased Line Services........................................................4-3

    4.2 V5 Service .....................................................................................4-65 TS Commissioning...................................................................................5-1

    5.1 Step 1: Connecting the LCI Terminal to the TS/BU.......................5-15.1.1 Global Navigation Key Symbol Commands ..............................5-2

    5.2 Step 2 Setting the Radio Link Parameters ....................................5-55.2.1 Setting the RFU Head Type......................................................5-55.2.2 Setting the IF Cable Length and Type.......................................5-6

  • 8/10/2019 ITMN Commissioning Guide

    4/56

    TABLE OF CONTENTS

    Page ii P/N 110503-00 D REV 1.0

    5.2.3 Setting Other Cable Gain Table ............................................. 5-9

    5.3 Step 3: TS Administrative Parameters........................................ 5-115.3.1 Setting the TS Customer ID.................................................... 5-115.3.2 Enabling the TS...................................................................... 5-12

    5.3.3 TS Scanning........................................................................... 5-13

  • 8/10/2019 ITMN Commissioning Guide

    5/56

    List of Figures

    P/N 110503-00 D REV 1.0 Page iii

    LIST OF FIGURES

    Figure 2-1: Block Diagram of the Commissioning Process .......................................2-2

    Figure 2-2: Direct Connection to BU..........................................................................2-4Figure 2-3: Network Connection to NMS...................................................................2-4Figure 3-1: Connecting a Local Craft Terminal to the BS..........................................3-4Figure 3-2: Connecting a Single Local Craft PC to the Base Units ...........................3-4Figure 3-3: Base RFU and Antenna Dialog .............................................................3-12Figure 3-4: E1 Port Configuration Dialog.................................................................3-20Figure 3-5: V.35/X.21 Port Configuration Dialog .....................................................3-22Figure 4-1: Leased Line Services Dialog...................................................................4-1Figure 4-2: Add Leased Line Services Dialog ...........................................................4-4Figure 5-1: Connecting a Local Craft Terminal to the TS..........................................5-1

  • 8/10/2019 ITMN Commissioning Guide

    6/56

    List of Tables

    Page iv P/N 110503-00 D REV 1.0

    LIST OF TABLES

    Table 3-1: Commissioning Using LCI ...................................................................... 3-1

    Table 3-2: Commissioning Using WALKnet............................................................. 3-1Table 3-3: Serial Communications cable Pin-to-Pin Mapping ................................. 3-3Table 3-4: Software Settings ................................................................................... 3-5Table 3-5: Global Navigation Key Symbol Commands............................................ 3-6Table 3-6: LCI Print Levels ...................................................................................... 3-6Table 3-7: RFU and Antenna Dialog Definitions.................................................... 3-12Table 3-8: Base Unit Administrative Status Options.............................................. 3-16Table 3-9: E1 Port Configuration Dialog Options................................................... 3-21Table 3-10: V.35/X.21 Port Configuration Dialog Definitions................................... 3-23Table 4-1: Leased Line Services Dialog Definitions ................................................ 4-2Table 4-2: Add Leased Line Service Dialog Definitions........................................... 4-5Table 5-1: Global Navigation Key Symbol Commands............................................ 5-2

    Table 5-2: LCI Print Levels ...................................................................................... 5-3

  • 8/10/2019 ITMN Commissioning Guide

    7/56

    P/N 110503-00 D REV 1.0 Page 1-1

    1 INTRODUCTION

    The WALKair V3.1 Commissioning Guide provides instructions for serviceand installation technicians, in order to facilitate the proper initialization andconfiguration of the WALKair V3.1 Base Station and Terminal Station.

    Detailed instruction relating to the operation of the WALKair V3.1 system isavailable in the WALKair V3.1 Operation and Maintenance Manual, and theWALKnet User Manual.

    1.1 Safety Precautions

    High voltages are present at specific points in this electrical equipment. Someof the parts can also have high operating temperatures. Non-observance ofthese conditions and safety instructions can result in personal injury or inproperty damage.

    The WALKair V3.1 system complies with the standard EN 60950. Allconnected equipment must comply with the applicable safety standards.

    Equipment complies with the following EMC and safety standards:

    EN 50081-1

    EN 55022 IEC 100-4-as 2, 3, 4, 5, 6, 8, 11

    ETSI 300339

  • 8/10/2019 ITMN Commissioning Guide

    8/56

  • 8/10/2019 ITMN Commissioning Guide

    9/56

    P/N 110503-00 D REV 1.0 Page 2-1

    2 OVERVIEW OF THE SYSTEM COMMISSIONING

    PROCESS

    This section provides a general overview of the commissioning process, andexplains system characteristics on first-time commissioning.

    The commissioning procedure is comprised of three stages:

    Commissioning of the BS.

    Commissioning of the TS

    Post Commissioning Acceptance Protocol Testing.

    The BS must be first in the commissioning procedure. This is to enableverification of each TS after commissioning. Failure to conform to theprocedure may result in undue travel, between the BS and TSs, for theinstallation personnel. Where it is determined that a TS is not serviceableafter commissioning, the installer will be able to take immediate correctiveactions. Figure 2-1 illustrates a block diagram of the Commissioning process.

  • 8/10/2019 ITMN Commissioning Guide

    10/56

    Chapter 2. Overview of the System Commissioning Process

    Page 2-2 P/N 110503-00 D REV 1.0

    FIGURE 2-1: BLOCK DIAGRAM OF THE COMMISSIONING PROCESS

    STEP 2

    IP Parameters

    LCI

    STEP 3

    Radio

    Parameters

    NMS / LCI

    STEP 4

    Administrative

    Parameters

    NMS / LCI

    STEP 5

    Telecom

    Parameters

    NMS / LCI

    STEP 6Define Services

    NMS / LCI

    TS CommissioningBS Commissioning

    STEP 3

    Administrative

    Parametes

    LCI

    STEP 1

    LCI Connection

    LCI

    STEP 1

    LCI Connection

    LCI

    STEP 2

    Radio Link

    Parameters

    LCI

    NOTE

    Step #3 - Step # 6 can be done via the LCI (Direct Connection).For a detailed description of the Commissioning Steps please refer to theOPAM Manual

    NOTE

    See Table 3-1 and Table 3-2 for a brief description of each step in theCommissioning process

  • 8/10/2019 ITMN Commissioning Guide

    11/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 2-3

    2.1 BS-BU Commissioning

    The BS Commissioning process is performed by the Commissioner via directconnection to the BU for the following:

    Connecting the LCI to the BS-BU

    Defining the Network Parameters

    All other BS Commissioning procedures are preformed by the Commissioneror Network Manager via WALKnet for the following:

    Radio Parameters

    Administrative Parameters

    Telecom Parameters

    Defining Services

    These parameters can be defined in two ways; by direct connection to the BUor by a Network connection to the NMS. Figure 2-2 illustrates a typical directconnection to the BU, and Figure 2-3 illustrates typical Network connection tothe NMS.

  • 8/10/2019 ITMN Commissioning Guide

    12/56

    Chapter 2. Overview of the System Commissioning Process

    Page 2-4 P/N 110503-00 D REV 1.0

    FIGURE 2-2: DIRECT CONNECTION TO BU

    Direct Cable

    RS-232

    BU

    LCI Port

    PC

    FIGURE 2-3: NETWORK CONNECTION TO NMS

    Network

    HubBU

    Router NMS

    NMS

  • 8/10/2019 ITMN Commissioning Guide

    13/56

    P/N 110503-00 D REV 1.0 Page 3-1

    3 GETTING STARTED

    This chapter describes the commissioning process for both the BS and TS.The commissioning process uses the LCI and the WALKnet User Manual asdescribed in Table 3-1 and Table 3-2.

    TABLE 3-1: COMMISSIONING USING LCI

    STEP DESCRIPTION REFERENCE

    1. Connect the Local Craft Terminal to the BU(s) See section3.1

    2. Set Network ParametersIP parametersSub

    See section3.4

    TABLE 3-2: COMMISSIONING USING WALKNET

    STEP DESCRIPTION WALKNET REFERENCE

    3. Setting theRadioParametersfor thefollowing:

    RFU Head Type

    IF Cable Type anddistance

    Cable Gain table

    Modem Working Point

    Setting IF Mux(8 or 16 Type)

    Frequency Index

    4.2.3 Frequency Planning4.3.5 Antenna Configuration

    4. SettingAdministrationParameters

    Base Station

    Terminal Station

    4.3.2 Editing Base Units4.7.3 Editing a Terminal

    5. Settingthe TelecomParameters

    Base Station

    Terminal Station

    4.3.6Telecom Port Configuration4.7.3 Editing a Terminal

  • 8/10/2019 ITMN Commissioning Guide

    14/56

    Chapter 3. Getting Started

    Page 3-2 P/N 110503-00 D REV 1.0

    STEP DESCRIPTION WALKNET REFERENCE

    6. Define Services4.4 Leased LineService Management(for E1 Service and V.35/X.21)

    4.5 V5 Configuration

    NOTE

    Repeat Steps 1 6 for each BU (1 8) installed in the BS.

    3.1 Step 1:Connecting the LCI Terminal to the BU

    3.2 Requirements

    In order to perform the commissioning process, you will require the following:

    PC platform as LCI

    Serial cable, TP4 wires, flat with RJ-45 to a 9-pin D-type or 25-pin D-typeconnectors

    Terminal Communications software(e.g. PROCOMM, PCPLUS, Hyper Terminal)

    3.3 RS-232 Serial Cable

    The Pin-to-Pin configuration of the serial cable used to connect between thePC and the WALKair V3.1 system is described in Table 3-3.

  • 8/10/2019 ITMN Commissioning Guide

    15/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-3

    TABLE 3-3: SERIAL COMMUNICATIONS CABLE PIN-TO-PIN MAPPING

    RJ45 PINS(BS/BU)

    SIGNAL NAME D TYPE 25 PINS(CPU)

    D TYPE 9 PINS(CPU)

    12 RXD 2 3

    3 TXD 3 2

    4

    5 GND 7 5

    6

    7

    8

  • 8/10/2019 ITMN Commissioning Guide

    16/56

    Chapter 3. Getting Started

    Page 3-4 P/N 110503-00 D REV 1.0

    Connection to a BS-BU is enabled via an RS-232 Communications CableThe RJ-45 end of the cable is connected to the RJ-45 receptacle marked LCI.The D-Type connector is connected to the communications port of the LocalCraft PC (see Figure 3-1).

    When more than one BS-BU is installed in the BS, the Local Craft PC can beinstalled with a Multi-Input/Output Expansion Card. This enables easyswitching between the BS-BUs (see Figure 3-2).

    FIGURE 3-1: CONNECTING A LOCAL CRAFT TERMINAL TO THE BS

    Local Craft Interface

    (LCI)

    Local Craft Terminal

    IBM Compatible PC

    RS-232 Communications

    Cable

    9 or 25 Pin D-Type to RJ-45

    FIGURE 3-2: CONNECTING A SINGLE LOCAL CRAFT PC TO THE BASE UNITS

    Local Craft Terminal

    IBM Compatible PC

    Multi-Input and Ouput Card

    1 - 8 Base Units

    1 - 8 Comm Cables

  • 8/10/2019 ITMN Commissioning Guide

    17/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-5

    3.3.1 LCI Software Settings

    The LCI embedded software, is VT-100 terminal compatible and uses theRS-232 interface. Attach the Local Craft Terminal to the BS-BU LCI port,

    using an available COM port with the settings as described in Table 3-4.TABLE 3-4: SOFTWARE SETTINGS

    ITEM SETTINGS

    Baud Rate 9600 bps

    Parity None

    Data Bits 8

    Stop Bits 1

    Protocol Type ASCII

    (For more information on the LCI, see the Base Station Management Guide)

    3.3.2 Global Navigation Key Symbol Commands

    The LCI software provides several global key symbol commands in order tofacilitate navigation of the Menu Structure as shown in Table 3-5.

    Type the then press in order to perform the requestedfunction.

  • 8/10/2019 ITMN Commissioning Guide

    18/56

    Chapter 3. Getting Started

    Page 3-6 P/N 110503-00 D REV 1.0

    TABLE 3-5: GLOBAL NAVIGATION KEY SYMBOL COMMANDS

    SYMBOLS FUNCTION

    * Press * to access the Main (root) menu in the software.

    From the main menu, you access all other LCI functions.

    ^ Press ^ to access the previous menu in the LCI screenin the LCI hierarchy.

    = Press = anytime to refresh the LCI monitor screen. Thiserases all information that was on the screen and re-displays thecurrent menu at the top of the screen.

    % Press % to toggle the ON/OFF display mode of errormessages should they occur.

    + Press + to advance the print level. The change isdisplayed on the LCI monitor.

    - Press - to reduce the print level. The change isdisplayed on the LCI monitor.

    The LCI reports system alarms and events by displaying messages on theterminal monitor. The type of messages that are printed depends on the setprint level.

    Table 3-6 lists the prints levels in descending order. Note that each print levelincludes the lower level messages.

    TABLE 3-6: LCI PRINT LEVELS

    PRINT LEVEL

    Info The default level displays all alarm and event messages,including status message (e.g., scanning frequencies).

    Warning Displays alarms that are the Warning Level.

    Error Displays alarms that are the Error Level.

    Fatal Displays alarms that are the Fatal Level.

    Display Displays no alarms or events, only the LCI menus.

    None Displays no alarms, events or LCI menus, (displays a blankscreen). If your LCI monitor displays a blank screen, press to reduce to the Display Print Level.

  • 8/10/2019 ITMN Commissioning Guide

    19/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-7

    To Connect the LCI Terminal to the BS-BU:

    1. Connect to the BU as described in section 3.1.

    2. Execute your Terminal Software.

    3. Power ON the BU.

    While initializing, the following messages are displayed on the terminalsoftware.

    4. Wait for completion of initialization;After the initialization, the Main Menu is displayed.

    Messages displayed during the initialization may interfere with the Main Menudisplay. Type then press to refresh the display.

  • 8/10/2019 ITMN Commissioning Guide

    20/56

    Chapter 3. Getting Started

    Page 3-8 P/N 110503-00 D REV 1.0

    3.4 Step 2:Setting Network ParametersIn order to connect the Management Station, the user must first define thefollowing IP parameters on the BS-BU:

    IP Address

    Network Mask

    Default IP Gateway Address

    Authorized Manager Station IP Address

    NOTE

    When physically connecting Ethernet, the BU must be rebooted in order toenable the port.

    3.4.1 Setting BU IP Parameters

    To Set the BU IP Paramerters:

    1. From the Main Menu, select option number 1 then press .The Configuration Menu is displayed.

    2. From the Configuration Menu, select option number 2 then press.The Administrative Parameters Menu is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    21/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-9

    3. From the Administrative Parameters Menu, select option 1 then press.The BS Parameters Menu is displayed.

    4. From the BS Parameters Menu, select option number 9 then press

    .The Set BU IP Parameters menu is displayed.

    5. Enter the required IP Address in the following format: XXX.XXX.XXX.XXX(four numbers separated by dots), then press .

    6. Enter the required IP Mask Address, then press .

    7. Enter the required Default Router IP Address, then press .

  • 8/10/2019 ITMN Commissioning Guide

    22/56

    Chapter 3. Getting Started

    Page 3-10 P/N 110503-00 D REV 1.0

    3.4.2 Adding Authorized Manager Stations

    After setting the BU IP Parameters, the following may be done sequentially byselecting option B from the BS Parameters Menu. You can add up to 5

    Authorized Managers as well as delete existing ones.

    To Add an Authorized Manager Statons:

    1. From the Main Menu, select option number 1 then press .The Configuration Menu is displayed.

    2. From the Configuration Menu, select option number 2 then press.The Administrative Parameters Menu is displayed.

    3. From the Administrative Parameters Menu, select option 1 then press.The BS Parameters Menu is displayed.

    4. From the BS Parameters Menu, select option B then press .The Add Authorized Manager Station menu is displayed.

    5. Enter the IP address for the new Manager Station in the following format:XXX.XXX.XXX.XXX (four numbers separated by dots), then press .

    Using the IP Address 255.255.255.255 enables any Management Stationaccess and control of the BU regardless of the Management Stationslocal IP Address.

  • 8/10/2019 ITMN Commissioning Guide

    23/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-11

    3.5 Step 3:Setting the Radio Parameters

    The remainder of the Commissioning process is performed using theWALKnet application and the WALKnet User Manual. Refer to the appropriatesection of the WALKnet User Manual for the following Commissioningprocedures.

    The RFU and Antenna Properties dialog contains all the RFU and Antennaparameters of the Base Station. You can view or edit the settings asdescribed in Table 3-7.New settings can be applied to specific BS-BUs aswell as all BS-BUs in a sector.

    Figure 3-3 displays the RFU and Antenna Dialogs for the BS-BU.

    See WALKnet section 4.2.3 Frequency Planningand section 4.3.5 AntennaConfigurationfor the following:

    Setting the Radio Parameters

    Set the RFU Head Type

    Set the IF Cable Type and lengthThe IF cable connects with the indoor and the outdoor units. Thesystem requires the IF cable attenuation data in order to adjust theoutput signal. The cable attenuation can either be entered manually,or computed by the system based on the specified IF length and type

    Set the IF Cable Type of cables other than the LMR400

    If Other Cable type was entered, the Gain table for the IF cablemust be entered as described by vendor specifications

    Set the Gain tableThe IF cable attenuation data can be computed by the system ormanually entered by the user. Prior to entering this option, ensurethat the cable gain (attenuation) has been measured.

    Setting the Modem Working Point for nominal Tx, Rx and default values.Typically, the default settings are used, however it is possible to configurethe Modem Working point in order to optimize modem performance.

    When setting the Modem Working Point, select either the default values or

    enter the Site Planning values for Tx and Rx.

    Setting the Frequency Index as specified in the Frequency PlanningSchedule.

  • 8/10/2019 ITMN Commissioning Guide

    24/56

    Chapter 3. Getting Started

    Page 3-12 P/N 110503-00 D REV 1.0

    FIGURE 3-3: BASE RFU AND ANTENNA DIALOG

    TABLE 3-7: RFU AND ANTENNA DIALOG DEFINITIONS

    DIALOG ELEMENT OPTIONS DESCRIPTION

    Antenna Section Type Displays the default antennaselection:

    VerticalAltitude Displays the height above

    sea level in meters.

    Heading Displays the Azimuthdirection relative to North.

    Beam Width Displays the current RadioFrequency coverage area ofthe BS-BU. The Beam Widthoptions are as follows:

    15, 30, 45, 60, 90

    RFU Section Type Displays the RFU Head Type.

    H/W Rev. Displays the RFU Head Typehardware revision.

    Redundancy Displays the currentRedundancy state.(Not available in the currentrelease).

  • 8/10/2019 ITMN Commissioning Guide

    25/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-13

    DIALOG ELEMENT OPTIONS DESCRIPTION

    Active RFU In the current release,displays the active (Main)RFU.

    IF Cable Section Type Displays the cable type.

    Length Displays the length of cable inmeters.

    Gain Valid Defines the validity of the Txand Rx Gain of the IF Cable.There are two options:

    ValidWhen selected, the BUwill accept only the Txand Rx gain defined

    parameters.

    InvalidWhen selected, the BUwill accept the cableparameters (Type andLength) for Cable Gaincalculation.

    Tx Gain Enables the user to define thecable Tx gain (in dB) for allfrequencies.

    Rx Gain Enables the user to define thecable Rx (in dB) for allfrequencies.

    Current Modem WorkingPoint Section

    Nominal Tx Power Enables the user to define theTx and Rx level of the BU RFcarrier. Type the default valueor enter a Nominal Powervalue for Tx (in dBm)

    Nominal Rx Power Type the default value orenter a Nominal Power valuefor Rx (in dBm).

    Cont

  • 8/10/2019 ITMN Commissioning Guide

    26/56

    Chapter 3. Getting Started

    Page 3-14 P/N 110503-00 D REV 1.0

    DIALOG ELEMENT OPTIONS DESCRIPTION

    Default Modem WorkingPoint

    Nominal Tx Power Displays the default ModemWorking Point for Nominal Tx(in dBm).

    Nominal Rx Power Displays the default ModemWorking Point for Nominal RxPower (in dBm).

    Check Box (For Base Station only) Select to Apply changes to allBS-BUs in the Sector.

    To View and Modify the Base RFU and Antenna Properties Dialog:

    1. Open the Base Station BU View dialog.

    2. From the BS-BU menu, select the RFU and Antenna option.The RFU and Antenna dialog is displayed.

    3. Enter the required parameters as described in Table 3-7 then click OK orApply.

    3.6 Step 4Setting the Administrative Parameters

    3.6.1 TS Administrative Parameters

    See WALKnet section 4.7.3 Editing a Terminal, for the following parameters: Defining the TS Customer ID

    Setting the estimated distance between the BS and TS.(If the estimated distance is less than 10 Km, enter 0. If the estimateddistance is more than 10 Km, enter 10).

    Defining the Administrative Status (enable/disable) for each TS in thesystem

    3.6.2 Registering a New Terminal

    To Register a New Terminal:

    1. From the Registered Terminals dialog, select a new Terminal Slotlocation.

    2. Right click the TS Slot.A context menu is displayed.

    3. Select the New TS option from the context menu.The Terminal Station Data dialog is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    27/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-15

    4. Enter the required parameters.

    5. Click OK to confirm and return to the Registered Terminals dialog.

    NOTE

    By default, all TSs are disabled and will not be able to communicate with itsassociated BS. Only enabled TSs can communicate with its associated BS.

    3.6.3 BS Administrative Parameters

    See WALKnet section 4.3.2 Editing Base Units, for the followingparameters:

    Defining the BS-BU Clock Source Defining the Administrative Status

    First Disable the unit, and then Enable it in order for the RadioParameters to be valid for the BU

    Editing Base Units defines the Administrative Status and Clock Sources ofany selected Base Unit in the Sector (see Table 3-8). A context sensitive Editmenu appears when double clicking or right clicking on the Base Station BUView dialog.

  • 8/10/2019 ITMN Commissioning Guide

    28/56

    Chapter 3. Getting Started

    Page 3-16 P/N 110503-00 D REV 1.0

    TABLE 3-8: BASE UNIT ADMINISTRATIVE STATUS OPTIONS

    DIALOG ELEMENT OPTIONS DESCRIPTION

    Admin Status Enable Enables the BS-BU to

    establish radio link withRegistered TS-BU(s).

    Disable Disables the radio linkbetween the BS-BU andthe Registered TS-BU(s).

    Clock Source Source Selection Defines the Clock selectionmode. There are twomodes:

    Manual

    Automatic When in AutomaticMode the ClockSource is selected bythe Base Station.

    Source Displays a list of availableclock sources when inManual Mode. There arefive clock sources:

    Internal

    External

    Telecom1

    Telecom2

    Telecom3

    Output Enables utilization of theBase Station output clocksignal to synchronize otherexternal equipment. Thereare two output clockstates:

    Enabled

    Disabled

  • 8/10/2019 ITMN Commissioning Guide

    29/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-17

    To Edit a Base Unit:

    1. From the Base Station BU View dialog, right click anywhere on the dialog.The Edit BS-BU context menu is displayed.

    2. Select the Edit BS-BU context menu.

    The Base Station BU Properties Edit dialog is displayed.

    3. From the Base Station BU Properties Edit dialog, select theAdministrative Status for the Base Unit.

    4. Select the required System Clock parameters.

    5. Click OK or Apply to confirm the setting.

  • 8/10/2019 ITMN Commissioning Guide

    30/56

    Chapter 3. Getting Started

    Page 3-18 P/N 110503-00 D REV 1.0

    3.7 Step 5Setting the BS/TS Telecom Parameters

    The WALKair Telecom Port Configuration dialogs enable you to define theTelecom port type and to configure its parameters for the BS-BU andRegistered TSs. You can configure the Telecom ports for Registered TSs thatare not connected or installed. Once a connection is established between theBS-BU and the TS-BU, the TS-BU receives these parameters.

    When updating the BS Telecom Configuration parameters, all ports areupdated and set to the Disable State. The displayed parameters for theTelecom Interface will vary depending on the type of Telecom card installedon each port.

    In the case of a mismatch between the configured and detected port types,

    WALKair transmits a Trap.

    See WALKnet section 4.3.6Telecom Port Configurationfor the following:

    Selecting the Telecom Card Type(E1 or V.35/X.21)

    Configuring the Telecom Card

    Defining the Telecom Card Administrative Status

    NOTE

    If an individual port does not contain a Telecom card, the port must beconfigured as, No Card.

    NOTE

    From the NMS, the BS/TS ports are numbered from 1 3. Facing the unit,Port 1 is located furthermost to the right, near the management port. Port 3 islocated furthermost to the left, near the IF interface

  • 8/10/2019 ITMN Commissioning Guide

    31/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-19

    To Access the Port Configuration Dialog:

    1. Open the Base Station BU View dialog.

    2. From the Base Station BU View Port Menu, select Edit Port.OR

    Right click a row item.OR

    From the Base Station BU View or Terminal Station BU Viewdouble-click on the Telecom Port display located at the bottom of thedialog.The Port Configuration dialog for the selected port type is displayed.

    3. From the Port Configuration dialog, modify the required parameters thenclick OK or Apply to confirm.

    3.7.1 Changing the Configured Port Type

    To Change the Configured Port Type:

    1. Open the Base Station BU View dialog.

    2. From the Base Station BU View Port Menu, select Change ConfiguredType.OR

    Right click a row item and select Change Configured Type from theContext menu.The Change Configured Port Type dialog is displayed.

    3. From the Change Configured Port Type dialog, select the required PortType then click Ok to confirm.

  • 8/10/2019 ITMN Commissioning Guide

    32/56

    Chapter 3. Getting Started

    Page 3-20 P/N 110503-00 D REV 1.0

    NOTE

    You cannot change the configuration of Port Types participating in Servicesor are in the Enabled Administrative State.

    NOTE

    All further definitions of services are according to the Configured Type.

    3.7.2 E1 Telecom Port Configuration

    Figure 3-4 displays the E1 Port Configuration dialog and Table 3-9 definesthe dialog options.

    FIGURE 3-4: E1 PORT CONFIGURATION DIALOG

  • 8/10/2019 ITMN Commissioning Guide

    33/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-21

    TABLE 3-9: E1 PORT CONFIGURATION DIALOG OPTIONS

    SETTINGS OPTIONS

    Line Type Indicates the variety of the E1 line.

    Unframed Double Frame

    Multi Frame CRC4

    Multi Frame CRC4 (ext)

    LOSS Alarm Mode Indicates standards used for the LOSSalarm criteria:

    ETSI ETS 300233

    ITU-T G.775

    Signaling Mode TransparentThe Transparent Signaling Mode

    cannot be defined if the E1 Line Typeis Unframed.

    CCS (Common Channel Signaling)The CCS Mode cannot be defined ifthe E1 Line Type is Unframed.

    NoneUsed only when the Line Type isUnframed.

    Loopback Mode Enables loopback testing for thefollowing:

    None

    Remote

    Local

    Payload

    Admin Status Displays the Administrative Status ofthe E1 port. States include:

    Enabled

    Disabled

  • 8/10/2019 ITMN Commissioning Guide

    34/56

    Chapter 3. Getting Started

    Page 3-22 P/N 110503-00 D REV 1.0

    3.7.3 Editing a V.35/X.21 Telecom Port

    Figure 3-5 displays the E1 Port Configuration dialog and Table 3-10 definesthe dialog options.

    FIGURE 3-5: V.35/X.21 PORT CONFIGURATION DIALOG

  • 8/10/2019 ITMN Commissioning Guide

    35/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 3-23

    TABLE 3-10: V.35/X.21 PORT CONFIGURATION DIALOG DEFINITIONS

    SETTINGS OPTIONS

    Data Rate (x64Kbps) The line data rate.

    Operating Mode Determines whether the Telecom cardfunctions in the DTE or DCE mode.

    DTE

    DCE

    Timing Mode The Timing Mode for the X.21 port isforced to Internal when in the DCEmode, and is forced to External in theDTE mode.

    Internal

    External

    Clock Mode Determinesthe polarity of the Clock.

    Standard

    Inverse

    Loopback Mode Enables loopback testing for thefollowing:

    None

    Remote

    Local

    Payload

    Admin Status Displays the Administrative Status of theV.35/X.21 port. States include:

    Enabled

    Disabled

  • 8/10/2019 ITMN Commissioning Guide

    36/56

    Chapter 3. Getting Started

    Page 3-24 P/N 110503-00 D REV 1.0

    3.8 Step 6Defining Services

    After configuring the Telecom Interface Type, define the types of servicesupported by the system per BS port TS port. By default, all services aredisabled.

    The system supports three types of leased line services:

    E1 transparent mode

    Fractional E1 mode

    V.35/X.21

    In addition, WALKair gives you the option to configure Services for theV5 Interface Protocol.

    See WALKnet section 4.4 Leased LineService Management(for E1 Service) and section 4.5 V5 Configurationfor the following:

    E1 Parameters

    Defining Service Bandwidth

    Defining Telecom Port Source

    E1 Start/End Time Slots

    NOTE

    By default, all E1 interfaces are disabled and must be enabled for operation

    V.35/X.21 Parameters

    Data Rate

    Operating Mode

    Timing Mode

    Clock Mode

    V5 Parameters:

    Service Bandwidth

    Port source

    Customer ID Destination (TS)

    Destination port at TS

  • 8/10/2019 ITMN Commissioning Guide

    37/56

    P/N 110503-00 D REV 1.0 Page 4-1

    4 LEASED LINE SERVICE MANAGEMENT

    The Leased Line Services dialog enables definition of Leased Line Servicesfrom the Telecom port of the specified BS-BU to the Telecom port ofTerminals in the system. You can configure these services for uninstalledand/or disconnected Terminal Stations. Once a connection is establishedbetween the BS-BU and the TS-BU, the TS-BU receives these parameters.

    WALKair supports Leased Line Services defined over both E1 Telecom cardsand V.35/X.21 Telecom cards participation in this service (see Figure 4-1).Table 4-1describes the dialog elements available from the Leased LineServices dialog.

    FIGURE 4-1: LEASED LINE SERVICES DIALOG

  • 8/10/2019 ITMN Commissioning Guide

    38/56

    Chapter 4. Leased Line Service Management

    Page 4-2 P/N 110503-00 D REV 1.0

    TABLE 4-1: LEASED LINE SERVICES DIALOG DEFINITIONS

    DIALOG ELEMENT OPTIONS DESCRIPTION

    Leased Line Services

    Menu

    Displays the Add, Edit, Delete, or

    Exit Leased Line Services dialogs.Context Menu Displayed by selecting a row item

    and right clicking, the contextmenu provides quick access toLeased Line Services menuoptions.

    Available ATS Indicator Displays the number of AvailableTime Slots (ATS).

    Port List BS Port Displays the operational TelecomPort for the selected BS-BU.

    BS Port Type Displays the BS TelecomInterface types. Port typesinclude:

    E1

    V.35

    X.21

    TS Port Displays the Telecom Interface for the associated TS.

    TS Port Type Displays the TS TelecomInterface. Port types include:

    E1

    V.35

    X.21

    Bandwidth(x 64KBPS)

    Displays the bandwidth(x 64KBPS) allocated for thespecified Leased Line Service.

    Oper Status Displays the Operational Status of the Leased Line Service. Statesinclude:

    Connected

    Disconnected

    Admin Status Displays the Administrative Statusof the Leased Line Service. Statesinclude:

    Enabled

    Disabled

  • 8/10/2019 ITMN Commissioning Guide

    39/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 4-3

    To Access the Leased Line Services Dialog:

    1. From the Configuration Menu, select Leased Line Services.The Base Station Selector dialog is displayed.

    2. Starting with the Cell drop list, select the location for each level in the

    WALKnet Navigation Model.3. Click OK to display the Leased Line Services dialog.

    4.1 Adding Leased Line Services

    When adding Leased Line Services, the following parameters must bedefined:

    Select the Terminal participating in this service.

    Select the port for the BS-BU and TS-BU. If the selected Port Type is E1,

    the first available E1 channel for the specified service should be assign. Select the Leased Line Service bandwidth from the drop list. Bandwidth for

    the BS-BU and TS-BU must be the same in both devices.

    Select the Administrative status.

    Figure 4-2 displays the Add Leased Line Service dialog andTable 4-2 describes the dialog definitions.

  • 8/10/2019 ITMN Commissioning Guide

    40/56

    Chapter 4. Leased Line Service Management

    Page 4-4 P/N 110503-00 D REV 1.0

    FIGURE 4-2: ADD LEASED LINE SERVICES DIALOG

  • 8/10/2019 ITMN Commissioning Guide

    41/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 4-5

    TABLE 4-2: ADD LEASED LINE SERVICE DIALOG DEFINITIONS

    DIALOG ELEMENT OPTION DESCRIPTION

    Base Station Section Port Displays a drop list of

    available BS Telecominterfaces (1-3).

    Port Type Displays the type of theselected BS TelecomInterface.

    Terminal Station Section Port Displays a drop list of available TS Telecominterfaces (1-3).

    Port Type: Displays a drop list of available TS Telecominterfaces (1-3).

    First E1 Channel When the selected port isE1, displays a drop list forthe first available E1channel.

    Leased Line ServicesSection

    Bandwidth Displays a list of availableBandwidths for LeasedLine Services.

    Oper Status Displays the operationalstatus of the Leased LineService. States include:

    Connected

    Disconnected

    Admin Status Displays the currentAdministrative status of theLeased Line Service.States include:

    Enabled

    Disabled

    Available ATS Displays the number ofavailable Air Time Slots in

    the system.

    To Add Leased Line Services:

    1. Open the Leased Line Services dialog.

    2. From the Leased Line Services menu, select Add Leased Line Service.OR

    Right click a Leased Line Services row item and select Add Leased Line

  • 8/10/2019 ITMN Commissioning Guide

    42/56

    Chapter 4. Leased Line Service Management

    Page 4-6 P/N 110503-00 D REV 1.0

    Service from the context menu.The Add Leased Line Service dialog is displayed.

    3. From the Add Leased Line Service dialog, select the Base Station port(1-3) for the new service from the drop list.

    The Port Type of the selected port is displayed.4. Select the First E1 channel (if Port Type is E1).

    5. Select the Terminal Station Customer ID from the drop list.

    6. Select the Bandwidth (n x 64Kbps) for the new service from the drop list.Consult available ATS

    7. Select the Administrative Status for the new service.

    8. Click OK to confirm settings.

    4.2 V5 Service

    For V5 Service protocols and configuration refer to section 4.5 in theWALKnet User Manual.

  • 8/10/2019 ITMN Commissioning Guide

    43/56

    P/N 110503-00 D REV 1.0 Page 5-1

    5 TS COMMISSIONING

    This chapter describes the commissioning process for the WALKair V3.1Terminal Station via the LCI. The TS Commissioning process is performed bythe Commissioner via direct connection to the TS-BU using the LCI for thefollowing:

    1. Connecting the Local Craft Terminal to the TS/BU

    2. Setting the Radio Link Parameters

    Setting the RFU Head Type

    Setting the IF cable length and type (IF cable gain)

    3. Setting the Administrative Parameters

    NOTE

    Repeat Steps 2 3 for each installed TS/BU.

    5.1 Step 1:Connecting the LCI Terminal to the TS/BU

    Connection to a TS/BU is made with an RS-232 Communications Cable.

    The RJ-45 connector is attached to the receptacle marked LCI. The D-Typeconnector is connected to the communications port of the Local Craft PC(see Figure 5-1).

    FIGURE 5-1: CONNECTING A LOCAL CRAFT TERMINAL TO THE TS

    Local Craft Interface (LCI)

    Local Craft Terminal

    IBM Compatible PC

    RS-232 Communications

    Cable

    9 or 25 Pin D-Type to RJ-45

  • 8/10/2019 ITMN Commissioning Guide

    44/56

    Chapter 5. TS Commissioning

    Page 5-2 P/N 110503-00 D REV 1.0

    5.1.1 Global Navigation Key Symbol Commands

    The LCI software provides several global key symbol commands in order tofacilitate navigation of the Menu Structure as shown in Table 3-5.

    Type the then press in order to perform the requestedfunction.

    TABLE 5-1: GLOBAL NAVIGATION KEY SYMBOL COMMANDS

    SYMBOLS FUNCTION

    * Press * to access the Main (root) menu in the software.From the main menu, you access all other LCI functions.

    ^ Press ^ to access the previous menu in the LCI screenin the LCI hierarchy.

    = Press = anytime to refresh the LCI monitor screen. Thiserases all information that was on the screen and re-displays thecurrent menu at the top of the screen.

    % Press % to toggle the ON/OFF display mode of errormessages should they occur.

    + Press + to advance the print level. The change isdisplayed on the LCI monitor.

    - Press - to reduce the print level. The change isdisplayed on the LCI monitor.

    The LCI reports system alarms and events by displaying messages on theterminal monitor. The type of messages that are printed depends on the setprint level.

    Table 5-2 lists the prints levels in descending order. Note that each print levelincludes the lower level messages.

  • 8/10/2019 ITMN Commissioning Guide

    45/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 5-3

    TABLE 5-2: LCI PRINT LEVELS

    PRINT LEVEL

    Info The default level displays all alarm and event messages,

    including status message (e.g., scanning frequencies).Warning Displays alarms that are the Warning Level.

    Error Displays alarms that are the Error Level.

    Fatal Displays alarms that are the Fatal Level.

    Display Displays no alarms or events, only the LCI menus.

    None Displays no alarms, events or LCI menus, (displays a blankscreen). If your LCI monitor displays a blank screen, press to reduce to the Display Print Level.

    To Connect the LCI Terminal to the TS/BU:

    1. Connect to the TS/BS.

    2. Execute your Terminal Software.

    3. Power ON the TS/BU.While initializing, messages are displayed on the terminal softwareinterface. Messages displayed during the initialization may interfere withthe main menu display.

    4. Type then press , to refresh the display.

    5. Wait for the completion of initialization.After the initialization, the Main Menu is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    46/56

    Chapter 5. TS Commissioning

    Page 5-4 P/N 110503-00 D REV 1.0

    The global key symbol commands facilitate navigation of the Menu Structure.(see Table 3-5).

    Type the then press in order to perform the requestedfunction.

  • 8/10/2019 ITMN Commissioning Guide

    47/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 5-5

    5.2 Step 2Setting the Radio Link Parameters

    NOTE

    Prior to setting the Radio Link Parameters, ensure that the TS-BU isDisabled (see section 5.3.2). If the TS-BU is already enabled, it must bedisabled.

    5.2.1 Setting the RFU Head Type

    To Set the RFU Head Type:

    1. From the Main Menu, select option number 1 then press .The Configuration Menu is displayed.

    2. From the Configuration Menu, select option number 1 then press.The Radio Link Parameters Menu is displayed.

    3. From the Radio Link Parameters Menu, select option number 9 thenpress .The following is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    48/56

    Chapter 5. TS Commissioning

    Page 5-6 P/N 110503-00 D REV 1.0

    4. Select the appropriate RFU head type for 3.5, 10.5 or 26 GHz thenpress .

    5. Select the RFU Head Revision [A] then press .

    5.2.2 Setting the IF Cable Length and Type

    Connection between the indoor and the outdoor units is made via the IFcable. Based upon the cable length and type entered in the LCI, the systemcalculates the attenuation and adjusts the signal to provide optimal gain.

    The IF cable length and type are entered in the Radio Link Parameters Menu.

    To Access Radio Link Parameters Menu:

    1. From the Main Menu, select option number 1 then press .

    The Configuration Menu is displayed.

    2. From the Configuration Menu, select option number 1 then press.The Radio Link Parameters Menu is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    49/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 5-7

    3. From the Radio Link Parameters Menu, select option number 1 then

    press .The Cable Length parameter input is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    50/56

    Chapter 5. TS Commissioning

    Page 5-8 P/N 110503-00 D REV 1.0

    4. Enter the length of the IF Cable in metersthen press .The Radio Link Parameters Menu is displayed.

    5. Specify the IF Cable Type, select option number 3 then press .The Cable Type parameter input is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    51/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 5-9

    6. Select option L then press to select standard LMR400 cable.

    7. Select option C then press to select the CF CU2Y S\50 ohmcable.

    8. Select option O then press to specify other cable classification.

    5.2.3 Setting Other Cable Gain Table

    If option O (Other Cable) type was entered, the Gain table for the IF cablemust be entered (as described by vendor specifications).

    To Set Other Cable Gain Paramters:

    1. From the Main Menu, select option number 1 then press .The Configuration Menu is displayed.

    2. From the Configuration Menu, select option number 1 then press.The Radio Link Parameters Menu is displayed.

    3. From the Radio Link parameters Menu, select option number 5 thenpress to complete the cable gain table.The Gain Table parameter input is displayed.

  • 8/10/2019 ITMN Commissioning Guide

    52/56

    Chapter 5. TS Commissioning

    Page 5-10 P/N 110503-00 D REV 1.0

    4. Enter the upstream gain as per vendor specification, in Decibels, thenpress .

    5. Enter the downstream gain as per vendor specification, in Decibels, press then press .

    6. Repeat for all relevant frequency indices (of the installed RFU)

    7. Type q to exit.The Radio Link Parameters Menu is displayed.

    NOTE

    A correct Cable Gain value is necessary for accuracy in measurement.

    All gain settings for cables other than the standard LMR400 must be set tospecifications supplied by the vendor.

  • 8/10/2019 ITMN Commissioning Guide

    53/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 5-11

    5.3 Step 3:TS Administrative Parameters

    5.3.1 Setting the TS Customer ID

    To Set the Customer ID Number:

    1. From the Main Menu, select option number 1 then press .The Configuration Menu is displayed.

    2. From the Configuration Menu, select option number 2 then press.The Administrative Parameters Menu is displayed.

    3. From the Administrative Parameters Menu, select option number 5 thenpress .

    The Customer ID input parameter menu is displayed.

    4. Type TS Customer ID number then press .This can be up to an 8 digit decimal number, from 0 9.

    TSs must be enabled in order for the BS to identify them. This is done byspecifying the TS Status via the Administrative Parameters Menu.

  • 8/10/2019 ITMN Commissioning Guide

    54/56

    Chapter 5. TS Commissioning

    Page 5-12 P/N 110503-00 D REV 1.0

    5.3.2 Enabling the TS

    To Access the Administrative Parameters Menu:

    1. From the Main Menu, select option number 1 then press .

    The Configuration Menu is displayed.2. From the Configuration Menu, select option number 2 then press

    .The Administrative Parameters Menu is displayed.

    3. From the Administrative Parameters Menu, select option number 3 thenpress .The TS Status parameter input is displayed.

    4. Type E then press to enable the TSOR

    Type D then press to disable the TS.

  • 8/10/2019 ITMN Commissioning Guide

    55/56

    WALKair V3.1 ITMN Commissioning Guide

    P/N 110503-00 D REV 1.0 Page 5-13

    5.3.3 TS Scanning

    The TS starts scanning the RFU for available frequencies, searching for adownlink transmission (seeks a signal above a certain threshold). When the

    received signal strength is above a certain threshold, the TS will attemptsynchronization.

    Upon success, the TS waits for the customer ID search message, with theCustomer ID in the downlink:

    If the Customer ID does not appear in the downlink, the TS continuesscanning.

    If the Customer ID appears in the downlink and matches the ID in the TS-BU,the scanning stops and the TS waits for EOC allocation.

  • 8/10/2019 ITMN Commissioning Guide