iologik 4000 modular remote i/o - moxa · scada software configuration. ... modbus specific driver...

14
email: [email protected] www.moxa.com 5-5-25 Industrial Networking Solutions Flexible remote I/O with a variety of I/O modules email: [email protected] www.moxa.com 5-25 5 Remote I/O > ioLogik 4000 Modular Remote I/O ioLogik 4000 Modular Remote I/O ioLogik remote I/O products from Moxa are used to connect a variety of sensors and actuators to computers and applications over standard Ethernet networks and the Internet. Sensors could be used for taking temperature, humidity, and light intensity readings, and actuators could include devices that apply pressure actuators and motor drives. Moxa also offers a line of RS-485 remote I/O servers that can be used with existing applications. By using one of Moxa’s NPort wireless device servers, you can even connect to sensors and devices over a wireless LAN network. Slice Type I/O Modules Removable Terminal Block Module Coding Tag Spring Type Terminal Block ioLogik 4000 servers provide spring type, removable terminal blocks (RTB) that allow you to preserve field wiring before replacing I/O expansion modules. Each I/O expansion module can be replaced quickly and easily. Easy Maintenance

Upload: duongdan

Post on 22-Apr-2018

228 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

emai l : [email protected] www.moxa.com 5-5-25

Industrial Networking Solutions

Flexible remote I/O with a variety of I/O modules

emai l : [email protected] www.moxa.com 5-25

5

Rem

ote I/O >

ioLogik 4000 Modular R

emote I/O

ioLogik 4000 Modular Remote I/O

ioLogik remote I/O products from Moxa are used to connect a variety of sensors and actuators to computers and applications over standard Ethernet networks and the Internet. Sensors could be used for taking temperature, humidity, and light intensity readings, and actuators could include devices that apply pressure actuators and motor drives. Moxa also offers a line of RS-485 remote I/O servers that can be used with existing applications. By using one of Moxa’s NPort wireless device servers, you can even connect to sensors and devices over a wireless LAN network.

Slice Type I/O Modules Removable Terminal Block Module Coding TagSpring Type Terminal Block

ioLogik 4000 servers provide spring type, removable terminal blocks (RTB) that allow you to preserve field wiring before replacing I/O expansion modules. Each I/O expansion module can be replaced quickly and easily.

Easy Maintenance

Page 2: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

www.moxa.com emai l : [email protected] 5-5-26 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-26

5

Rem

ote I/O >

ioLogik 4000 Modular R

emote I/O

ioAdmin allows you to configure and monitor ioLogik 4000 modular I/O servers remotely. ioAdmin automatically detects the installed ioLogik Ethernet I/O server and presents the installation sequence of the I/O modules. ioAdmin also detects and generates a Modbus address table, which can be printed or stored on a computer for SCADA software configuration.

The utility also allows you to:

1. Automatically search for installations

2. Look for help using online documentation

3. Generate reports of I/O combinations

What You See Is What You Install !!

Easy-to-Use Windows Utility

Self-diagnostic Function for Digital Output Channels

Remote Confi guration

ioAdmin is a powerful, Windows-based configuration and management tool. You can use ioAdmin to modify the IP address, update communication parameters, and configure all other settings easily. In addition, ioAdmin can be used to configure ioLogik modular I/O servers from a remote host. This means that ioLogik modular I/O servers can be configured from anywhere over the Ethernet, which can help reduce your operating expense.

The M-2402, M-2403, M-2404, and M-2405 modules include a self-diagnostic function to guarantee that the digital output signal is monitored electronically. The hardware-monitored status is written to

the logic system, and you can obtain the actual digital output status over the network when the software sends a command to the module. This is all done internally, and configuration is not required.

Although ioAdmin is the main configuration interface for ioLogik servers, you can also check the following information using the ioLogik server’s web console:

• Network configuration

• Modular I/O

• Status of each channel

Although ioAdmin is the main configuration interface for ioLogik

Check Remote I/O Status with a Web Browser

Page 3: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

emai l : [email protected] www.moxa.com 5-5-27

Industrial Networking Solutions

Dimensions (unit = mm)

emai l : [email protected] www.moxa.com 5-27

5

Rem

ote I/O >

ioLogik 4000 Modular R

emote I/O

Supports Various SCADA Software Packages

Versatile Software Support

Modular Remote I/O

SCADA DAQ Software

SCADA SoftPLC

OPC Client

Modbus SpecificDriver

3rd PartyOPC Server

Visual BasicC-Applications

Programming ToolsProgramming Tools

MXIO DLL

Utility & DiagnosticsUtility & Diagnostics

ioAdminWindows Utility

RS-232/485 Ethernet

Host ComputerHost Computer

SCADA Software PackagesSCADA Software Packages

Modbus/TCPModbus/RTU

I/O Module DimensionsI/O Network Adaptor15 (0.60")

99 (3.90")

30 (1.18")

70 (2.75")

12 70 (2.75")

35 (1.38")

99 (3.90")

60 (2.36")

30 (1.18")

36 (1.42")28 (1.10")

Modular Remote I/O

ioLogik 4000 servers support the standard Modbus protocol and are compatible with most SCADA software. In addition, Moxa provides an easy-to-use MXIO DLL library that helps programmers develop application software with Visual Basic or C language under Windows.

The ioLogik 4000 line was designed for the standard Modbus protocol and can be used with most SCADA systems. The following SCADA software is compatible with ioLogik 4000 servers: Modicon Driver, Wonderware Intouch, GE Fanuc iFix and CIMPLICITY, Broadwin, kingview, and Citect. In addition, we successfully tested the OPC Server “Kepware,” which means that ioLogik 4000 servers can be accessed either from a SCADA system or through an OPC Server.

Note: The installation guides for different SCADA software packages can be downloaded from Moxa’s download center.

Side ViewSide View Side View Front ViewFront View Removable View

70 (2.75") 42 (1.65")

99 (3.90")

36 (1.42")35 (1.38")

28 (1.10")

99 (3.90")

60 (2.36")

70 (2.75")

99 (3.90")

36 (1.42")35 (1.38")

28 (1.10") 60 (2.36")

Page 4: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

www.moxa.com emai l : [email protected] 5-5-28 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-28

5

Rem

ote I/O >

ioLogik 4000 Modular R

emote I/O

Digital Input Modules

Specs

Model M-1400 M-1401 M-1410 M-1411 M-1800 M-1801 M-1600 M-1601 M-1450 M-1451

Channels 4 4 4 4 8 8 16 16 4 4

Sink/Source Sink Source Sink Source Sink Source Sink Source – –

Connector RTB RTB RTB RTB RTB RTB 20-pin 20-pin RTB RTB

Voltage 24 VDC 24 VDC 48 VDC 48 VDC 24 VDC 24 VDC 24 VDC 24 VDC 110 VAC 220 VAC

Isolation Optical isolation

Digital Output Modules

Specs

Model M-2400 M-2401 M-2800 M-2801 M-2600 M-2601 M-2402 M-2403 M-2404 M-2405 M-2250 M-2254

Channels 4 4 8 8 16 16 4 4 4 4 2 2

Sink/Source Sink Source Sink Source Sink Source Sink Source Sink Source Relay Triac

Connector RTB RTB RTB RTB 20-pin 20-pin RTB RTB RTB RTB RTB RTB

Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 230 VAC/ 24 VDC

12 to 125 VDC

Current 0.5A 0.5A 0.5A 0.5A 0.3A 0.3A 0.5A 0.5A 2.0A 2.0A 2.0A 0.5A

Isolation Optical isolation

Diagnostics – – – – – – Yes Yes Yes Yes – –

Analog Input Modules

Specs

Model M-3400 M-3402 M-3410 M-3412 M-3414 M-3401 M-3403 M-3411 M-3413 M-3415 M-6200 M-6201

Channels 4 4 4 4 4 4 4 4 4 4 2 2

Current 0 to 20 mA

4 to 20 mA – – – 0 to 20

mA4 to 20

mA – – – – –

Voltage – – 0 to 10V -10 to 10V 0 to 5V – – 0 to 10V -10 to

10V 0 to 5V – –

Connector RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB RTB

Resolution 12-bit 12-bit 12-bit 12-bit 12-bit 14-bit 14-bit 14-bit 14-bit 14-bit – –

Isolation Optical isolation

SensorInput – – – – – – – – – – RTD

(Ohm)

Thermo-couple(µV)

Analog Output Modules

Specs

Model M-4201 M-4202 M-4210 M-4211 M-4212

Channels 2 2 2 2 2

Current 0 to 20 mA 4 to 20 mA – – –

Voltage – – 0 to 10V -10 to 10V 0 to 5V

Resolution 12-bit 12-bit 12-bit 12-bit 12-bit

Connector RTB RTB RTB RTB RTB

Isolation 1K VDC galvanic isolation

Modular Remote I/O Selection Guide

I/O Modules

Power Modules

Specs

Model M-7001 M-7002 M-7803 M-7804 M-7805 M-7806

Channels 0 0 8 8 8 8

Voltage 24 VDC DC: 5, 24, 48 VDCAC: 110/220 VAC - 0 V 24 VDC 4 for 0 VDC

4 for 24 VDC

Purpose System power Field power Shield signal Field power Field power Field power

Page 5: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

emai l : [email protected] www.moxa.com 5-5-29

Industrial Networking Solutions

Ethernet network adaptor module

emai l : [email protected] www.moxa.com 5-29

5

Rem

ote I/O >

NA-4010

NA-4010

0 1

2 3

4 5

6 7

CH0 CH0

CH0 CH0

CH0 CH0

CH0 CH0

ioLogik 4000Modbus TCP/IPNA-4010

SYSLINKACTIVEI/O

FieldPower

0 1

2 3

4 5

6 7

SG

Field Power (0 VDC)Field Power (24 VDC)

SG

24V 0V

0V 0V

24V 24V

System Power (0 VDC)

System Power (24 VDC)

Field Power (0 VDC)

Field Power (24 VDC)

Shielding Ground

System Power (5 VDC)System Power (GND)

System Bus

Non-isolationSwitchingPower

Specifi cations

NetworkEthernet: 10/100 Mbps, RJ45

Software Features Protocols: Modbus/TCP, HTTP, BootpIP Settings: ARP, Bootp, static IPUtility: ioAdminProgramming Library: MXIO DLL library for Windows supporting Visual Basic, Visual C++, Borland C++ BuilderNumber of I/O Modules: Max. of 32 I/O expansion modules

Power Requirements Power Input: 11 to 28.8 VDC, 24 VDC typicalPower Consumption: 60 mA typical @ 24 VDCCurrent for I/O Modules: Max. 1.5A @ 5 VDC

Field Power Rated Voltage: 11 to 28.8 VDC, 24 VDC typicalCurrent in Field Power Contact: Max. 10A

IsolationSystem Power to I/O Driver: Optical isolation

Environmental LimitsOperating Temperature: -20 to 60°C, 5 to 90%RHStorage Temperature: -45 to 85°CVibration: IEC-68-2-6, 2G in operation

Regulatory ApprovalsEMC: CE EN-55082, EN-55081Safety: UL 508

WeightNet Weight: 150 g

Ordering Information

NA-4000 Series M-1000/2000/3000/4000/6000 Series M-7000 Series

Step 1: Select a Network Adaptor Module Step 2: Select I/O Modules Step 3: Select Power Modules (optional)

NA-4010: Ethernet Network Adaptor (Modbus/TCP)

*The NA-4010 Ethernet Network Adaptor is expandable with up to 32 I/O modules. Please refer to pages 5-31 to 5-44 to select the M-series modules that you need for your own application.

The certifi cation logos shown here apply to some or all of the products in this section. Please see the Specifi cations section or Moxa’s website for details.

Page 6: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

www.moxa.com emai l : [email protected] 5-5-30

RS-485 or RS-232 network adaptor modules

www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-30

5

Rem

ote I/O >

NA-4020/4021

NA-4020/4021

Specifi cationsSerial CommunicationBaudrate: 1200 to 115200 bpsData Bits: 7, 8Parity Bits: None, Even, OddStop Bits: 1, 2Signals:NA-4020: Data+, Data-, Gnd, DIRNA-4021: TxD, RxD, Gnd

Software FeaturesProtocols: Modbus/RTU, Modbus/ASCIIModbus Address: 00 to 99 by rotary switchesUtility: ioAdminProgramming Library: MXIO DLL library for Windows supporting Visual Basic, Visual C++, Borland C++ BuilderNumber of I/O Modules: Max. of 32 I/O expansion modules

Ordering Information

0 1

2 3

4 5

6 7

CH0

CH0

CH0 CH0

ioLogik 4000Modbus RS-485NA-4020

SYSTxDRxDI/O

FieldPower

0 1

2 3

4 5

6 7

SG

Field Power (0 VDC)Field Power (24 VDC)

SG

24V 0V

0V 0V

24V 24V

System Power (0 VDC)

System Power (24 VDC)

Field Power (0 VDC)

Field Power (24 VDC)

Shielding Ground

System Power (5 VDC)System Power (GND)

System Bus

Non-isolationSwitchingPower

NA-4000 Series M-1000/2000/3000/4000/6000 Series M-7000 Series

Step 1: Select a Network Adaptor Module Step 2: Select I/O Modules Step 3: Select Power Modules (optional)

NA-4020: RS-485 Network Adaptor (Modbus)

NA-4021: RS-232 Network Adaptor (Modbus)

*The NA-4020/4021 RS-485/RS-232 Adaptors are expandable with up to 32 I/O modules. Please refer to pages 5-31 to 5-34 to select the M-series modules that you need for your own application.

Power RequirementsPower Input: 11 to 28.8 VDC, 24 VDC typicalPower Consumption: 70 mA typical @ 24 VDCCurrent for I/O Modules: Max. 1.5A @ 5 VDC

Field PowerRated Voltage: 11 to 28.8 VDC, 24 VDC typicalCurrent in Field Power Contact: Max. 10A

IsolationSystem Power to I/O Driver: Optical isolation

Environmental LimitsOperating Temperature: -20 to 60°C, 5 to 90%RHStorage Temperature: -45 to 85°CVibration: IEC-68-2-6, 2G in operation

Regulatory ApprovalsEMC: CE EN-55082, EN-55081Safety: UL 508

WeightNet Weight: 150 g

The certifi cation logos shown here apply to some or all of the products in this section. Please see the Specifi cations section or Moxa’s website for details.

Page 7: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

emai l : [email protected] www.moxa.com 5-5-31

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-31

5

Rem

ote I/O >

Digital Input M

odules

M-1800 8 digital inputs, sink, 24 VDCInputs per Module: 8 points, sink typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: External commonPower Consumption: Max. 35 mA @ 5 VDC

M-1401 4 digital inputs, source, 24 VDCInputs per Module: 4 points, source typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

24V 24V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1400

Status

0

1

23

M-1400 4 digital inputs, sink, 24 VDCInputs per Module: 4 points, sink typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

24V 24V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1401

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

M-1800

Status

0

1

23

4

5

6

7

Digital Input Modules4 or 8-channel 24 VDC digital input modules4 or 8-channel 24 VDC digital input modules

M-1801 8 digital inputs, source, 24 VDCInputs per Module: 8 points, source typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ 1.5 ms

Common Type: External commonPower Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

M-1801

Status

0

1

23

4

5

6

7

Page 8: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

www.moxa.com emai l : [email protected] 5-5-32 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-32

5

Rem

ote I/O >

Digital Input M

odules

M-1411 4 digital inputs, source, 48 VDCInputs per Module: 4 points, source typeOn-state Voltage: 48 VDC nominal, min. 34 VDC to max. 60 VDCMin. Off-state Voltage: Max. 10 VDCOn-state Current: Max. 4 mA / point @ 48 VDCInput Impedance: Typ. 12K ohmsCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

M-1410 4 digital inputs, sink, 48 VDCInputs per Module: 4 points, sink typeOn-state Voltage: 48 VDC nominal, min. 34 VDC to max. 60 VDCMin. Off-state Voltage: Max. 10 VDCOn-state Current: Max. 4 mA / point @ 48 VDCInput Impedance: Typ. 12K ohmsCommon Type: 4 points/2 COMPower Consumption: Max. 35 mA @ 5 VDC

16-channel 24 VDC digital input modules

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

48V 48V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (48 VDC)

* Field Power distributor required.

M-1410

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

48V 48V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (48 VDC)

* Field Power distributor required.

M-1411

Status

0

1

23

M-1600 16 digital inputs, sink, 24 VDC Inputs per Module: 16 points, sink typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 msCommon Type: 16 points/2 COM Power Consumption: Max. 40 mA @ 5 VDC

M-1601 16 digital inputs, source, 24 VDCInputs per Module: 16 points, source typeOn-state Voltage: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCMin. Off-state Voltage: Max. 5 VDCOn-state Current: Max. 6 mA / point @ 28.8 VDCInput Impedance: Typ. 5.1K ohmsFiltering Time: Typ. 1.5 ms

Common Type: 16 points/2 COM Power Consumption: Max. 40 mA @ 5 VDC

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1600

Status

3 71115

2 61014

1 5 9 13

0 4 8 12

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

M-1601

Status

3 71115

2 61014

1 5 9 13

0 4 8 12

4-channel 48 VDC digital input modules

Page 9: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

emai l : [email protected] www.moxa.com 5-5-33

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-33

5

Rem

ote I/O >

Digital Input M

odules

4-channel 110/220 VAC digital input modules

M-1451 4 digital inputs, 220 VACInputs per Module: 4 pointsOn-state Voltage: 240 VAC nominal, min. 170 VAC to max. 264 VACMin. Off-state Voltage: Max. 45 VACOn-state Current: Max. 12 mA / point @ 264 VACInput Impedance: Typ. 22K ohmsCommon Type: 4 points/2 COM (single common)Power Consumption: Max. 35 mA @ 5 VDC

M-1450 4 digital inputs, 110 VACInputs per Module: 4 pointsOn-state Voltage: 120 VAC nominal, min. 85 VAC to max. 132 VACMin. Off-state Voltage: Max. 45 VACOn-state Current: Max. 8 mA / point @ 132 VACInput Impedance: Typ. 11K ohmsCommon Type: 4 points/2 COM (single common)Power Consumption: Max. 35 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

N N

L L

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (110 VAC N)Field Power (110 VAC L)

* Field Power distributor required.

M-1450

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

N N

L L

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (220 VAC N)Field Power (220 VAC L)

* Field Power distributor required.

Field Power (220 VAC)

M-1451

Status

0

1

23

Ordering Information

Digital Input Modules

Specs

Model M-1400 M-1401 M-1410 M-1411 M-1800 M-1801 M-1600 M-1601 M-1450 M-1451

Channels 4 4 4 4 8 8 16 16 4 4

Sink/Source Sink Source Sink Source Sink Source Sink Source – –

Connector RTB RTB RTB RTB RTB RTB 20-pin 20-pin RTB RTB

Voltage 24 VDC 24 VDC 48 VDC 48 VDC 24 VDC 24 VDC 24 VDC 24 VDC 110 VAC 220 VAC

Isolation Optical isolation

Page 10: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

www.moxa.com emai l : [email protected] 5-5-34 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-34

5

Rem

ote I/O >

Digital O

utput Modules

M-2400 4 digital outputs, sink, 24 VDC, 0.5AOutputs per Module: 4 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points /4 COM (single common)Power consumption: Max. 45 mA @ 5 VDC

Digital Output Modules

4 or 8-channel 24 VDC digital output modules4 or 8-channel 24 VDC digital output modules

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

24V

24V 24V

0 1

2 3

24V

M-2400

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0V 0V

M-2401

Status

0

1

23

M-2401 4 digital outputs, source, 24 VDC, 0.5AOutputs per Module: 4 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points/4 COM (single common)Power Consumption: Max. 45 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

L

L

L

L

M-2800

Status

0

1

23

4

5

6

7

M-2800 8 digital outputs, sink, 24 VDC, 0.5AOutputs per Module: 8 points, sink typeOutput Voltage Range: 24 VDC nominal, min.11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 8 points/External common (single common)Power Consumption: Max. 60 mA @ 5 VDC

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

CH4 CH5

CH6 CH7

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

Field Power (24 VDC)Field Power (0 VDC)

L

L

L

L

M-2801

Status

0

1

23

4

5

6

7

M-2801 8 digital outputs, source, 24 VDC, 0.5AOutputs per Module: 8 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 8 points/external common (single common)Power Consumption: Max. 60 mA @ 5 VDC

Page 11: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

emai l : [email protected] www.moxa.com 5-5-35

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-35

5

Rem

ote I/O >

Digital O

utput Modules

M-2403 4 digital outputs, diagnostics, source, 24 VDC, 0.5AOutputs per Module: 4 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points /4 COM (single common)Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

M-2402 4 digital outputs, diagnostics, sink, 24 VDC, 0.5AOutputs per Module: 4 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.5A per channel Common Type: 4 points/4 COM (single common)Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

4-channel digital output modules with diagnostics

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

24V

24V 24V

0 1

2 3

24V

M-2402

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0V 0V

M-2403

Status

0

1

23

M-2405 4 digital outputs, diagnostics, source, 24 VDC, 2AOutputs per Module: 4 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 2A per channel Common Type: 4 points/4 COM (single common)Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

M-2404 4 digital outputs, diagnostics, sink, 24 VDC, 2AOutputs per Module: 4 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff leakage Current: Max. 50 µAOutput Current Rating: Max. 2A per channel Common Type: 4 points/4 COM (single common)

Self Diagnostics: YesPower Consumption: Max. 45 mA @ 5 VDC

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

24V

24V 24V

0 1

2 3

24V

M-2404

Status

0

1

23

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

0V 0V

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

0V 0V

M-2405

Status

0

1

23

Page 12: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

www.moxa.com emai l : [email protected] 5-5-36 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-36

5

Rem

ote I/O >

Digital O

utput Modules

M-2600 16 digital outputs, sink, 24 VDC, 0.3AOutputs per Module: 16 points, sink typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.3A per channel

Max. 4A per commonCommon Type: 16 points / 2 COM (single common)Power Consumption: Max. 80 mA @ 5 VDC

16-channel digital output modules

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

LLLLLL

M-2600

Status

3 71115

2 61014

1 5 9 13

0 4 8 12

24V24V

0V0V

1514

1312

1110

98

76

54

32

1Ch0

0 1

18 19

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

L

L

LLLLLL

M-2601

Status

7111561014

1 5 9 13

0 4 8 12

M-2601 16 digital outputs, source, 24 VDC, 0.3AOutputs per Module: 16 points, source typeOutput Voltage Range: 24 VDC nominal, min. 11 VDC to max. 28.8 VDCOn-state Voltage Drop: Max. 0.3 VDC @ 25°COn-state Current: Min. 1 mA per channelOff Leakage Current: Max. 50 µAOutput Current Rating: Max. 0.3A per channel

Max. 4A per common

Common Type: 16 points / 2 COM (single common)Power Consumption: Max. 80 mA @ 5 VDC

Page 13: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

emai l : [email protected] www.moxa.com 5-5-37

Industrial Networking Solutions

emai l : [email protected] www.moxa.com 5-37

5

Rem

ote I/O >

Digital O

utput Modules

0 1

2 3

4 5

6 7

CH0 CH1

Ch0 Ch1

L1 L1

L2 L2

0 1

2 3

System Power (5 VDC) System Power (GND)

System Bus

Field Power (N or 0 VDC) Field Power (230 VAC or 24 VDC)

* Field power distributor required when the field power is not 24 VDC.

L

L

COM (to N or 0 VDC)

M-2250

Status

0

1

0 1

2 3

4 5

6 7

CH0 CH1

NC NC

N N

L L

0 1

2 3

System Power (5 VDC)System Power (GND)

System Bus

Field Power (110 VAC N)Field Power (110 VAC L)

* Field Power distributor required when the field power is not 24 VDC.

L

L

to 125 VAC

M-2254

Status

0

1

NC: No Connection

2-channel relay output module

M-2254 2 digital outputs, Triac, 12 to 125 VAC, 0.5AOutputs per Module: 2 pointsSwitch Type: Zero crossingRated Load Voltage: 15 to 132 VACOutput Current Rating: 0.05 to 0.5AFrequency Range: 47 to 63 HzSurge Current: 40A (16 ms) /4A (30S)On-state Voltage Drop: 1.3 Vrms (max. load)Off-state Leakage Current: Max. 1.5 mACommon Type: 2 points / 2 COMPower Consumption: Max. 35 mA @ 5 VDC

M-2250 2 digital outputs, relay, 24 VDC/230 VAC, 2AOutputs per Module: 2 points, relay Relay Type: Form A, Normally Open (N.O.) Single Pole, Single Throw (SPST)Output Voltage Range: Load dependent 5 to 28.8 VDC / 2A resistive 48 VDC / 0.8A resistive 110 VAC / 0.3A resistive 250 VAC / 2A resistiveMin. Load: 100 µA, 100 m VDC per pointMax. On-state Voltage Drop: 0.5V @ 2A, resistive load, 24 VDCOff-state Leakage Current: Max. 1.5 mACommon Type: 1 point/1 COMPower Consumption: Max. 65 mA @ 5 VDC

Ordering Information

Digital Output Modules

Specs

Model M-2400 M-2401 M-2800 M-2801 M-2600 M-2601 M-2402 M-2403 M-2404 M-2405 M-2250 M-2254

Channels 4 4 8 8 16 16 4 4 4 4 2 2

Sink/Source Sink Source Sink Source Sink Source Sink Source Sink Source Relay Triac

Connector RTB RTB RTB RTB 20-pin 20-pin RTB RTB RTB RTB RTB RTB

Voltage 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 24 VDC 230 VAC/ 24 VDC

12 to 125 VDC

Current 0.5A 0.5A 0.5A 0.5A 0.3A 0.3A 0.5A 0.5A 2.0A 2.0A 2.0A 0.5A

Isolation Optical isolation

Diagnostics – – – – – – Yes Yes Yes Yes – –

Page 14: ioLogik 4000 Modular Remote I/O - Moxa · SCADA software configuration. ... Modbus Specific Driver 3rd Party OPC Server Visual Basic C-Applications ... ioLogik 4000 Modular Remote

www.moxa.com emai l : [email protected] 5-5-38 www.moxa.com emai l : [email protected]

Remote Monitoring Solutions

5-38

5

Rem

ote I/O >

Analog Input Modules M-3410 4 analog inputs, 0 to 10V, 12 bits

M-3412 4 analog inputs, -10 to 10V, 12 bitsM-3414 4 analog inputs, 0 to 5V, 12 bitsInput SpecificationsResolution in Ranges: 12 bits, 2.44 mV/bit (M-3410) 12 bits, 4.88 mV/bit (M-3412) 12 bits, 1.22 mV/bit (M-3414)Input Current Range: 0 to 10 VDC (M-3410) -10 to 10 VDC (M-3412) 0 to 5 VDC (M-3414)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 500K ohmsConversion Time: 4 ms / all channels

General SpecificationsPower Consumption: Max. 150 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

M-3400 4 analog inputs, 0 to 20 mA, 12 bitsM-3402 4 analog inputs, 4 to 20 mA, 12 bitsInput SpecificationsResolution in Ranges: 12 bits, 4.88 µA/bit (M-3400) 12 bits, 3.91 µA/bit (M-3402)Input Current Range: 0 to 20 mA (M-3400) 4 to 20 mA (M-3402)Data Format: 16-bit integer (2’s complement)Accuracy: ±0.1%, FSR @ 25°C ±0.3%, FSR @ 0°C, 60°CInput Impedance: 120 ohmsConversion Time: 4 ms / all channels

General SpecificationsPower Consumption: Max. 150 mA @ 5 VDCIsolation: I/O to logic: Photocoupler isolationWiring: I/O cable max. AWG14

Analog Input Modules

4-channel analog input modules, 12-bit resolution4-channel analog input modules, 12-bit resolution

4-channel analog input modules, 12-bit resolution Power (GND)System Bus

Field Power (0 VDC) Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

G

CG CG

0 1

2 3

G

Voltage 0 to 10V (M-3410/3411) Voltage -10 to 10V (M-3412/3413) Voltage 0 to 5V (M-3414/3415)

Shielding Ground

M-34xx

Status

0

1

23

4-channel analog input modules, 12-bit resolution Power (5 VDC)

System Power (5 VDC)System Power (GND)

System Bus

Field Power (0 VDC)Field Power (24 VDC)

0 1

2 3

4 5

6 7

CH0 CH1

CH2 CH3

G

CG CG

0 1

2 3

G

Current 0 to 20mA (M-3400/3401)

Shielding Ground

Current 4 to 20mA (M-3402/3403)

M-34xx

Status

0

1

23