INTRALINK IDR-C IDU

Indoor Unit

Installation and Cabling Instructions

Manual Code: GDC-001/82

Manual Edition: 1

Page 2: Intralink IDR-C IDU Installation and Wiring Instructions 01

INTRACOM S.A. TELECOM SOLUTIONS 19,7 km Markopoulou Ave., 19002 Peania, Athens, Greece,

Tel: (+30 210) 66 79 000, Fax: (+30 210) 66 79 001, http://www.intracom.com

INTRACOM TELECOM, 2006. All rights reserved. All copyright, intellectual and industrial rights in this document and in the technical knowledge it contains are owned by INTRACOM TELECOM and/or their respective owners. This document is made available to the end users only for their internal use. No part of this document nor any data herein may be published, disclosed, copied, reproduced, redistributed by any form or means, electronically or mechanically, or used for any other purpose whatsoever without the prior written approval of INTRACOM TELECOM. Information as well as drawings and specifications contained in this document are subject to change without prior notice. All trademarks and copyrights mentioned herein are the property of INTRACOM TELECOM and/or their respective owners. Any rights not expressly granted herein are reserved. Printed in Greece.

Page 3: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU– Installation and Cabling Instructions

i

Table of Contents

Safety Precautions............................................................................................... iii

Chapter 1: Introduction................................................................................................................. 1 About this Document.............................................................................................1 Target Audience ...................................................................................................1

Chapter 2: About IDU................................................................................................................... 2 Product Composition.............................................................................................2 Dimensions and Weights ......................................................................................4 Transportation and Storage ..................................................................................4

Chapter 3: Before starting the Installation .................................................................................... 5

Site Requirements and Preparation ..................................................................................................... 5

Supplementary Accessories ................................................................................................................. 5

Tools ........................................................................................................................................................ 5

Connectors Pin-out ................................................................................................................................ 6 Power Connector ..................................................................................................6 DS 1-4, DS 5-8, DS 9-12, DS 13-16 Connectors ..................................................7 NMS1, NMS2 Connectors...................................................................................10 AUX ....................................................................................................................11 TRIB 1-4 Connector ............................................................................................13 10/100 ETHERNET Connector ...........................................................................14 COM Connector ..................................................................................................14 ODU Connector ..................................................................................................15

Cables.................................................................................................................................................... 16 Assembled Cables .............................................................................................................. 16

RG-142 Tail Cable ..............................................................................................16 D25/BNC Conversion Cable ...............................................................................17

Disassembled Cables ......................................................................................................... 18 Preparing the Power Supply Cable .....................................................................18 Preparing the IDU Grounding Cable ...................................................................19

Cables not provided ............................................................................................................ 20 E1 Tributaries Cable ...........................................................................................20 LCT Cable...........................................................................................................20 Ethernet Cable....................................................................................................20

Chapter 4: Installation & Cabling Instructions ............................................................................ 21 Installing the IDU ................................................................................................22 Grounding the IDU..............................................................................................23 Connecting the E1 Tributaries ............................................................................24 Connecting the Power Supply.............................................................................25 Connecting the RG-142 Tail Cable .....................................................................26

Page 4: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

ii

(page intentionally left blank)

Page 5: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU– Installation and Cabling Instructions

iii

Safety Precautions

PROPER GROUNDING Never power up the indoor equipment not yet connected to a proper grounding system. There is risk of equipment failure and/or electrical shock. Ensure that both the indoor and outdoor grounding systems measure a path resistance less than 10 Ω.

ESD PROTECTION Always use proper antistatic protection (i.e. grounding bracelet, antistatic bags, etc.) when handling the IDR-C cards. Parts bearing the ESD sign (see left) have ESD sensitive exposed components.

Page 6: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

iv

(page intentionally left blank)

Page 7: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

1

Chapter 1: Introduction

About this Document

This document provides information concerning the installation and the

cabling of the IDR-C IDU (Indoor Unit).

Target Audience

This document is intended for technicians with knowledge and skills

concerning the installation and cabling of units.

Page 8: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

2

Chapter 2: About IDU

Product Composition

IDU in 1+0 topology

1 2 3

1

2

Item Description 1 Indoor Unit (IDU) 2 Outdoor Unit (ODU)

IDU in 1+1 topology

1

23

Item Description 1 Indoor Unit (IDU) 2 Outdoor Unit A (ODU A) 3 Outdoor Unit B (ODU B)

Continued on next page

Page 9: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

3

Product Composition, Continued

IDU composition

1

1

3

2 4

4

Item Description

1 Power Supply Unit (in 1+0 topology, the upper unit is replaced by a dummy panel)

2 CMS Unit (together with the MUX Unit serve 16 x 2 Mbit/s tributaries) Alternatively and depending on the application, the IDU can be composed of the: • CMS version with an Ethernet interface • CMS version for 4 x 2 Mbit/s tributaries

3 MUX (to serve 16 x 2 Mbit/s tributaries) 4 Framer/Modem/Cable Interface Unit (in 1+0 topology,

the upper unit is replaced by a dummy panel)

Page 10: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

4

Dimensions and Weights

Technical characteri-stics

Find the IDU dimensions and weight in the following table:

Item Dimensions Weight (max)

IDU (1+0 topology) 5 kg IDU (1+1 topology) 440 mm x 240 mm x 90 mm 6 kg

Transportation and Storage

Transporta-tion and storage conditions

The product is designed to be transported and stored under the following conditions: • Temperature: -40 °C to +70 °C • Relative Humidity: 90% to 100% at +30 °C (condensation)

93% at +30 °C (steady state)

NOTE

The preceding values apply only when the product is in its package.

Page 11: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

5

Chapter 3: Before starting the Installation

Site Requirements and Preparation

• The equipment shelter of the indoor units should preserve a

temperature within the operating range –5oC to +55oC. • The IDR-C operates only on negative power supply, from –40 V dc

to –60 V dc. • The positive pole of the power supply source at the IDR-C station

should be grounded. • The suggested value for the fuse of the power supply source at the

IDR-C station is 10 A.

Supplementary Accessories

The following accessories required for the installation and cabling of

the IDR-C IDU are not included in the package.

Item Description Used for the 1 E1 tributaries cable IDR-C connection to the E1

tributaries at the installation site

2 LCT cable IDR-C connection to the LCT

3 Ethernet cable IDR-C connection to an Ethernet Switch at the installation site

4 Four M6 x 12 screws, four washers and four M6 caged nuts

IDU mounting on the rack

Tools

• Philips (cross-headed) screwdriver for M5 screws

• Blade • Soldering iron (65 W approximately) • Crimping tool for bared grounding lugs • Crimping tool for insulated grounding lugs

Page 12: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

6

Connectors Pin-out

Power Connector

Location The power connector is located on the front panel of the IDU PSU.

Scope The connector is used for the connection of –48 V dc power supply

voltage.

Type D-Type 3 Male power connector

Pin-out

Pin no. Signal - -Vin

GND

+ +Vin/GND

Page 13: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

7

DS 1-4, DS 5-8, DS 9-12, DS 13-16 Connectors

Location The DS 1-4, DS 5-8, DS 9-12, DS 13-16 connectors are located on the

front panel of the IDU MUX.

Scope The connectors are used to connect four E1 tributaries each (thus 16 x

E1 tributaries).

Type D-Sub 25 Female connectors

Continued on next page

Page 14: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

8

DS 1-4, DS 5-8, DS 9-12, DS 13-16 Connectors, Continued

Pin-out (75 Ω)

12345678910111213

25 24 23 22 21 20 19 18 17 16 15 14

Pin Signal Description 1 GND 2 OUT 4 GND 3 IN 4 GND 4 GND 5 OUT 3 GND 6 IN 3 GND 7 GND 8 OUT 2 GND 9 IN 2 GND

10 GND 11 OUT 1 GND 12 IN 1 GND 13 GND 14 OUT 4 P Positive OUT 4 15 IN 4 P Positive IN 4 16 GND 17 OUT 3 P Positive OUT 3 18 IN 3 P Positive IN 3 19 GND 20 OUT 2 P Positive OUT 2 21 IN 2 P Positive IN 2 22 GND 23 OUT 1 P Positive OUT 1 24 IN 1 P Positive IN 1 25 GND

Continued on next page

Page 15: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

9

DS 1-4, DS 5-8, DS 9-12, DS 13-16 Connectors, Continued

Pin-out (120 Ω)

12345678910111213

25 24 23 22 21 20 19 18 17 16 15 14

Pin Signal Description 1 GND 2 OUT 4 N Negative OUT 4 3 IN 4 N Negative IN 4 4 GND 5 OUT 3 N Negative OUT 3 6 IN 3 N Negative IN 3 7 GND 8 OUT 2 N Negative OUT 2 9 IN 2 N Negative IN 2

10 GND 11 OUT 1 N Negative OUT 1 12 IN 1 N Negative IN 1 13 GND 14 OUT 4 P Positive OUT 4 15 IN 4 P Positive IN 4 16 GND 17 OUT 3 P Positive OUT 3 18 IN 3 P Positive IN 3 19 GND 20 OUT 2 P Positive OUT 2 21 IN 2 P Positive IN 2 22 GND 23 OUT 1 P Positive OUT 1 24 IN 1 P Positive IN 1 25 GND

Page 16: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

10

NMS1, NMS2 Connectors

Location The NMS1, NMS2 connectors are located on the front panel of the IDU

CMS.

Scope The connectors are used to connect the LCT and the NMS. You can

use the connectors alternatively.

Type D-Sub 9 Male connectors

Pin-out

54321

6 7 8 9

Pin Signal Description 1 CD Carrier Detect 2 RX Receive Data 3 TX Transmit Data 4 DTR Data Terminal Ready 5 GND 6 DSR Data Set Ready 7 RTS Ready To Send 8 CTS Clear To Send 9 N.C. Not Connected

Page 17: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

11

AUX

Location The AUX connector is located on the front panel of the IDU CMS.

Scope The connector is used to connect:

• Internal and External Alarms • Four RS-232 Service Channels • One 2 Mbit/s Service Channel (G.703, 120 Ω, balanced) (only for the

16 x 2 Mbit/s CMS version) • Two 4W telephone lines (A and B) for simultaneous bi-directional

communication with 4-wire telephone sets (600 Ω, balanced) Note: The service bit rate of the service channels depends on the traffic capacity of the system provided in the following table:

Traffic Capacity

(Mbit/s) 2 Mbit/s Service

Channel Baud Rate of 1 to 4

RS-232 Service Channel (bit/s)

34 Supported 9600 16 x 2 Supported 9600 8 x 2 Not supported 19200 4 x 2 Not supported 9600 2 x 2 Not supported 4800

Type D-Sub 37 Female connector

Continued on next page

Page 18: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

12

AUX, Continued

Pin-out

12345678910111213141516171819

37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20

Pin Signal Description 1 OUT_2MB_P 2Mb/s Service Channel OUT POSITIVE 2 GND 3 IN_2MB_P 2Mb/s Service Channel IN POSITIVE 4 R1IN RS-232 Service Channel 1 IN 5 GND RS-232 Service Channel GND 6 R2IN RS-232 Service Channel 2 IN 7 R3IN RS-232 Service Channel 3 IN 8 GND RS-232 Service Channel GND 9 R4IN RS-232 Service Channel 4 IN 10 4WTX1_B 4W telephone line B Tx1 11 4WRX1_B 4W telephone line B Rx1 12 4WTX2_B 4W telephone line B Tx2 13 4WRX2_B 4W telephone line B Rx2 14 GND 15 EXOUT1 External Alarm Output 1 16 EXOUT3 External Alarm Output 3 17 EXIN1 External Alarm Input 1 18 EXIN3 External Alarm Input 3 19 GND External Alarm Inputs GND 20 OUT_2B_N 2Mb/s Service Channel OUT NEGATIVE 21 GND 22 IN_2MB_N 2Mb/s Service Channel IN NEGATIVE 23 T1OUT RS-232 Service Channel 1 OUT 24 GND RS-232 Service Channel GND 25 T2OUT RS-232 Service Channel 2 OUT 26 T3OUT RS-232 Service Channel 3 OUT 27 GND RS-232 Service Channel GND 28 T4OUT RS-232 Service Channel 4 OUT 29 4WTX1_A 4W telephone line A Tx1 30 4WRX1_A 4W telephone line A Rx1 31 4WTX2_A 4W telephone line A Tx2 32 4WRX2_A 4W telephone line A Rx2 33 GND_FL External Alarm Outputs Floating GND 34 EXOUT2 External Alarm Output 2 35 EXOUT4 External Alarm Output 4 36 EXIN2 External Alarm Input 2 37 EXIN4 External Alarm Input 4

Page 19: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

13

TRIB 1-4 Connector

Location The TRIB 1-4 connector is located on the front panel of the IDU CMS

(version for 4 x 2 Mbit/s tributaries).

Scope The connector is used to connect four E1 tributaries.

Type D-Sub 25 female connector

Pin-out

12345678910111213

25 24 23 22 21 20 19 18 17 16 15 14

For the pin-out, see par. “Pin-out (75 Ω)”, on page 8 and par. “Pin-out (120 Ω), on page 9.

Page 20: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

14

10/100 ETHERNET Connector

Location The 10/100 ETHERNET connector is located on the front panel of the

IDU CMS (version for Ethernet interface).

Scope The connector is used for the LAN connection.

Type RJ-45 shielded connector (100Base-TX)

Pin-out

Pin no. Signal 1 Tx+ 2 Tx- 3 Rx+ 4 5 6 Rx- 7 8

COM Connector

(for future use)

Page 21: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

15

ODU Connector

Location The ODU connector is located on the front panel of the IDU

Framer/Modem/Cable Interface Unit.

Scope The connector is used to connect the ODU through an IF cable.

Type N-type Female connector

Page 22: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

16

Cables

Assembled Cables

RG-142 Tail Cable

Drawing

1

2

Item Description

1 N-type, male, R/A connector 2 N-type female connector

Scope This cable connects the IDU with the IF cable coming from the ODU.

The cable protects the ODU connector on the front panel of the IDU against mechanical damage, which might occur in case of direct connection of the heavy IF cable.

Type RG-142

Connectors The one end of the cable is terminated with an N-type female

connector while the other end is terminated with n N-type, male, R/A connector.

Length 1,5 m

From/To The cable connects the ODU connector on the front panel of the IDU

to the IF cable coming from the ODU.

Page 23: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

17

D25/BNC Conversion Cable

Drawing

OUT 3

OUT 4

OUT 2

OUT 1

IN 4

IN 3

IN 2

IN 1IN 1

IN 2

IN 3

IN 4

OUT 1

OUT 2

OUT 3

OUT 4

1

2

Item Description Qty

1 D25 male connector 1 2 BNC female connector 8

Scope Four such cables connect the DS connectors of the IDU with a special

conversion panel the manufacturer provides on customer’s request.

Note: The aforementioned conversion panel provides BNC receptacles for the 2 Mbit/s tributaries in case the D-Sub 25 female connectors on the IDU front panel are not convenient to the customer.

Connectors The one end of the cable is terminated with a D25 male connector

while the other end is terminated with eight BNC female connectors.

Length 70 cm

From/To Each cable connects one of the DS connectors on the front panel of

the IDU to the aforementioned conversion panel the manufacturer provides on customer’s request.

Page 24: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

18

Disassembled Cables

Preparing the Power Supply Cable

Tools • Blade

• Cross-headed screwdriver • Soldering iron (65 W approximately)

Accessories • D-Type 3 Female power connector (provided)

• Power Supply cable, 2 x 2,5 mm2 stranded, PVC, black, 300 V (the manufacturer provides 5 m of cable)

NOTE

For the 1+1 topology, prepare two power supply cables, one for every power supply unit.

NOTE

The manufacturer can provide on request a power supply switchboard with all the necessary accessories.

Preparing the cable

To prepare the cable, follow the steps below:

Step Action

1 Strip the wires of the cable as shown below:

BLUE

BROWN8 mm

17 mm

2 Unscrew the two screws of the provided female power supply connector to dismantle it.

3 Insert and solder the brown wire to the A3 pin of the connector and the blue wire to the A1 pin of the connector.

(+Vin/GND)

(-Vin)

A3

A2

A1BLUE

BROWN

A1A2

A3

4 Assemble the connector again using the two screws.

Page 25: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

19

Preparing the IDU Grounding Cable

Tools • Special crimping tool for insulated grounding lugs

• Blade

Accessories • Insulated grounding lug for a 6 mm2 cable, screwed on the IDU

(provided) • Insulated grounding lug for a 6 mm2 cable (provided) • Grounding cable, 6 mm2 stranded, PVC, green/yellow, 450 V (the

manufacturer provides 3 m of cable)

Prerequisite Estimate the length of the grounding cable needed up to the grounding

point of the rack.

Preparing the cable

To prepare the cable, follow the steps below:

Step Action

1 Strip cable to dimensions shown:

2 Slide the insulated grounding lug over the wires:

3 Crimp with the special crimping tool. 4 Repeat steps 2 and 3 for the other end of the cable. In the

end of the procedure the cable will look as below:

Page 26: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

20

Cables not provided

This section provides info concerning cables not provided by the

manufacturer.

E1 Tributaries Cable

The IDU receptacles for the E1 tributaries cables are D-Sub 25

Female.

LCT Cable

The IDU connector for the LCT cable is D-Sub 9 Female.

NOTE

To prepare the cable, see the NMS1, NMS2 connectors pin-out, on page 10.

Ethernet Cable

The IDU receptacle for the Ethernet cable is RJ-45 shielded (100Base-

TX). You will need a cross-over UTP CAT5 cable.

Page 27: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

21

Chapter 4: Installation & Cabling Instructions

To install and cable the IDR-C IDU, follow the steps below taking into

consideration the following Caution:

Only trained and qualified personnel should install or replace this equipment.

Step Action

1 Install the IDU (page 22). 2 Ground the IDU (page 23). 3 Switch-off the IDU PSU(s). 4 Connect the E1 tributaries (page 24). 5 Connect the power supply to the IDU (page 25). 6 Connect the RG-142 tail cable (page 26). 7 Connect the LCT (optional).

Page 28: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

22

Installing the IDU

Ensure 1U free space above and below the IDU in the rack for ventilation purposes.

Tools Philips screwdriver for M5 screws

Accessories Four M6 x 12 screws, four washers and four M6 caged nuts (not

provided)

Procedure Use four M6 x 12 screws and mount the IDR-C on the rack:

321

Item Description Qty 1 Screw, M6 x 12, DIN7985 INOX 4 2 Nylon Finishing Washer D=6,4 Black 4 3 Caged Nut, M6, ST.ZINC PL. 4

Page 29: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

23

Grounding the IDU

Prerequisites • This procedure requires a prepared grounding cable according to the

description on page 19. • Make sure that the installation premises is equipped with a reliable,

low-impedance ground connection system.

Tools Philips screwdriver for M5 screws

Accessories • Grounding cable (see par. “Preparing the IDU Grounding Cable”, on

page 19) • M5 x 10 screw (provided, it is screwed on the right side panel of the

unit)

Procedure To ground the IDR-C, follow the steps below:

Step Action 1 Use the M5 x 10 screw and the two washers provided to

connect the yellow grounding lug to the IDU.

2 Connect the other insulated grounding lug to the rack

grounding bar.

Page 30: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

24

Connecting the E1 Tributaries

Prerequisites This procedure requires that you have prepared the cables for the E1

tributaries.

NOTE

The manufacturer can provide on request a special conversion panel with BNC receptacles for the 75 Ω E1 tributaries. The conversion panel is connected to the IDU through special D25/BNC conversion cables (see page 17) provided by the manufacturer.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Procedure Connect the E1 tributaries to the DS 1-4, DS 5-8, DS 9-12, DS 13-16

connectors on the front panel of the IDU MUX.

In case you have the conversion panel

If you have the aforementioned conversion panel with the BNC receptacles for the 75 Ω E1 tributaries and in order to connect the E1 tributaries to the IDU, follow the steps below:

Step Action

1 Plug the D25 connectors of the conversion cables to the DS 1-4, DS 5-8, DS 9-12, DS 13-16 connectors on the front of IDU.

2 Remove the washer and the nut from each BNC receptacle of the conversion cables.

3 Insert the BNC receptacles from behind the conversion panel and then screw the washer and the nut from the front to secure.

4 Connect the E1 tributaries to the appropriate BNC receptacles of the conversion panel.

Page 31: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C_IDU_InstallationandWiringInstructions_01 IDR-C IDU – Installation and Cabling Instructions

25

Connecting the Power Supply

Prerequisites • The IDR-C operates only on negative power supply, from -40 V dc to

–60 V dc. • The positive pole of the power supply source at the IDR-C station

should be grounded. • The suggested value for the fuse of the power supply source at the

IDR-C station is 10 A. • This procedure requires that you have prepared the power supply

cable as described on page 18.

Accessories Power supply cable (see par. “Preparing the Power Supply Cable”, on

page 18).

Procedure To connect the power supply to the IDR-C, follow the steps below

taking into consideration the following Caution:

Risk of arc production at the contacts of the IDU PSU connectors! Do not connect the power supply to the IDR-C before you make sure the positive pole of the power supply source at the IDR-C station is grounded.

Step Action

1 Switch-off the power supply source at the IDR-C station. 2 Switch-off the PSU(s) of the IDR-C.

3 Connect the power supply cable(s) to the station power supply source.

4 Plug the power supply cable(s) to the power supply connector(s) on the front panel of the PSU(s).

NOTE

In 1+1 topology, cable both PSUs of the IDR-C.

Page 32: Intralink IDR-C IDU Installation and Wiring Instructions 01

IDR-C IDU – Installation and Cabling Instructions IDR-C_IDU_InstallationandWiringInstructions_01

26

Connecting the RG-142 Tail Cable

Why to make the connection

You should connect the IF cable coming from the Outdoor Unit to the RG-142 tail cable to protect the ODU connector on the front panel of the IDU against mechanical damage which might occur in case of direct connection of the heavy IF cable.

Accessories RG-142 Tail Cable (provided)

Procedure Connect the male connector of the tail to the ODU connector on the

front panel of the IDU.

NOTE

The female connector of the tail will be connected to the N-type connector of the IF cable coming from ODU.