instrumentation in neurosurgery

Upload: sedaka26

Post on 03-Apr-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 Instrumentation in Neurosurgery

    1/101

    Presented by : Noufal Basheer

  • 7/28/2019 Instrumentation in Neurosurgery

    2/101

  • 7/28/2019 Instrumentation in Neurosurgery

    3/101

    Thermal energy for haemostasis,dates back topharaonics,

    The earliest known surgical records - in papyrusdocuments from Egypt dated as early as 3000

    B.C. called fire drilla device which whenturned ra idl roduced heat alon

    Hot iron

    Bovie and Cushing in 1920s

    Lasers in 1960s

    10/18/2008 3instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    4/101

    10/18/2008 4instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    5/101

    variety of electrical waveforms

    a constant waveform, - This producesea very rap y, o vapor ze or cu ssue.

    an intermittent waveform, produce lessheat. Instead of tissue vaporization, a

    coagulum is produced.

    10/18/2008 5instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    6/101

    10/18/2008 6instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    7/101

    Electrical energy in the range of 250000 to 2

    million Hz Heating effect Depends upon the density of

    current Size of electrode should be as small as possible Fat,bone and air have low water content and

    hence high resistance

    contact to ensure low current density Healing is slower by 2 days,with wound having

    less tensile strength and larger scar (Vs scalpel

    cut) Increased susceptibility to wound infection

    10/18/2008 7instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    8/101

    The active electrode is in the wound.

    The patient return electrode is attachedsomewhere else on the patient. The functionof the patient return electrode is to removecurrent from the patient safely.

    The current must flow through the patientto the patient return electrode.

    10/18/2008 8instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    9/101

    10/18/2008 9instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    10/101

    Choose: Well vascularized muscle mass

    Avoid: Vascular insufficiency

    Irregular body contours

    Bony prominences

    Consider: Incision site/prep area

    Patient position

    Other equipment on patient

    Return Electrode Monitoring, actively monitor the amount ofimpedance at the patient/pad interface and deactivate system

    10/18/2008 10instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    11/101

    cut Coagulation blend

    Continuous wave pulsed Continuous,with

    resting period

    yellow blue blue

    Coagulationcontact

    spray

    Endo cut: fractionated cutting under water

    10/18/2008 11instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    12/101

    10/18/2008 12instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    13/101

    10/18/2008 13instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    14/101

    Waveform

    Power Setting

    Size of Electrode, The smaller the electrode, theg er e curren concen ra on

    Time

    Manipulation of Electrode

    Type of Tissue

    Eschar

    10/18/2008 14instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    15/101

    Start up self check Return electrode continuity monitor Contact quality monitoring Return current feedback monitor Hi h fre uenc leaka e monitor Earth leakage monitor Output error monitoring Smoke filtration

    Activation time limit alarm Do not activate the generator while the active

    electrode is touching or in close proximity toanother metal object

    10/18/2008 15instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    16/101

    Power output should be sufficient to

    achieve the desired surgical effect but

    should not be too high, Power

    surgical effect, the active electrode size

    and type of tissue to be treated

    10/18/2008 16instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    17/101

    Greater precision and less damage to tissue Less power needed Current flows through one blade and out

    through other Only the tissue grasped is included in the

    electrical circuit

    muscles and nerves More effective for coagulating tissue under a

    layer of fluid

    Radionics vs malis bipolar instrumentssensing device ,no need of

    irrigation,chances of inadequate coagulation

    10/18/2008 17instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    18/101

    coagulation cut

    ablation

    ss

    scissors

    10/18/2008 18instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    19/101

    Optimum distance between electodes

    Continuous irrigation with saline

    Charred tissue should be wiped off with

    ,Tip diameter use

    1.5,2 mm Large vessels and scalp

    bleeders,fascia ,muscles

    .7-1mm Dura and brain surface

    .5 mm Tissue close to blood

    vessels,nerves,and

    brainstem

    10/18/2008 19instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    20/101

    Shaft length

    8cm Brain surface to depth of 2

    cm

    9.5 cm Deeper regions

    10 cm TNTS,posterir third ventricle

    Power range 0.1 9.9 watts 1-50 watts

    adjustability 0.1 watts 1 watt

    Precise point

    coagulation

    Universal use

    10/18/2008 20instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    21/101

    Shafts of different length available

    Self irrigating forceps,pre irrigation and postirrigation function

    Jet irrigation systems in haematomas

    Transistorized coagulator system,equipped withthemocontrole system( sugita and tsugane)

    Ohta etal,irrigation on when forceps is close

    PTFE coated forceps

    10/18/2008 21instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    22/101

    10/18/2008 22instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    23/101

    10/18/2008 23instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    24/101

    10/18/2008 24instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    25/101

    Formation of coagulum

    Adherence of the blood vessel to the tip of the

    Penetration of aneurysm

    Undesirable regional tisssue damage due to

    grounding of current through the body10/18/2008 25instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    26/101

    Current flow should not be started till the desiredbleeder is reached

    Current setting should be reduced when changing tofine tipped forceps

    Coagulation should be done in a small pool of water

    When irrigated it should not be flooded

    When using on a vessel forceps should be pulsated

    Current should be set as low as possible

    Should be cleaned immediately after use

    10/18/2008 26instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    27/101

    Decreased smoke, odor

    Noncontact in coagulation mode

    Decreased blood loss, rebleeding

    Decreased tissue damage

    Flexible eschar10/18/2008 27instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    28/101

    leading ultrasonic cutting and coagulation surgicaldevice

    using lower temperatures than those used byelectro surgery or lasers

    vessels are coapted (tamponaded) and sealedby a protein coagulum

    Coagulation occurs by means of protein

    denaturation when the blade couples withprotein denaturs to form a coagulum thatseals small coapted vessels

    10/18/2008 28instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    29/101

    control of harmonic Scalpels coagulation rate &cutting speed depends on time & force applied tothe tissue by the end effector.

    The Harmonic Scalpel uses ultrasonic technology,& energy that allows both cutting & coagulation atthe point of impact.

    As compared to electro surgery

    1) fewer instrument exchanges are needed

    2) less tissue charring and desiccation occur

    3) visibility in the surgical field is improved.

    10/18/2008 29instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    30/101

    10/18/2008 30instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    31/101

    Types :

    CO2 laser,

    Nd : YAG Laser,

    Argon Laser,

    KTP laser

    Principle : Photocoagulation

    Explosive tissue vapourisation

    Coagulation,vapourization,haemostasis,Cutting10/18/2008 instrumentation in neurosurgery 31

  • 7/28/2019 Instrumentation in Neurosurgery

    32/101

  • 7/28/2019 Instrumentation in Neurosurgery

    33/101

    Development of early tools trephination to latestmotor powered microdrills

    Records of neurosurgery from 3000 BC shows

    1st evidence of trephination

    hand operated drill in dentistry- 100 AD

    First powered instrument devised by George f. green,English dentist in 1869

    Sir Heneage Ogilve 1st air powered drill & osteotome

    Robert m hall forest c barber devoloped modern highspeed drills

    10/18/2008 33instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    34/101

    System comprises of1) Motors

    2) Pneumatic control unit with regulator &various connectors

    3) Various attachments & dissectingtools

    4) Lubricant/diffuser10/18/2008 34instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    35/101

    Vane type is the hallmark

    Rotor spindle housed in rotor housing

    Vanes are incorporated on lengthwise slots on the rotor spindle

    Speed ranges from 65000 to 100000 rpm

    Speed more than 25000 bone meltsaway easily

    - no tactile sensation

    10/18/2008 35instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    36/101

    10/18/2008 36instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    37/101

    Great precision

    Time saving

    If used properly it is the safest, for both patients &

    surgeon

    10/18/2008 37instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    38/101

    Stable body

    Microscope should be positioned in a comfortable

    o eratin osition

    All loose materials should be removed from the field

    Hand piece should be of light weight & should be held

    in pen holding position

    10/18/2008 38instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    39/101

    Drilling underwater :

    1) It allows the neurosurgeon to visualize prospectivestructures through bone, which becomes semitransparent when

    adequately hydrated

    2) Underwater drilling protects key neuroanatomical structures

    from thermal in ur

    3) Irrigation serves to constantly wash the head of the drill bit

    Visualizing critical structures through bone

    10/18/2008 39instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    40/101

    Drilling parallel to underlying structures

    The movement of the drill bit should proceed along the axis of

    the underlying structure being exposed. the sigmoid, means a

    10/18/2008 40instrumentation in neurosurgery

    predominantly superior-inferior motion, whereas for the middle

    fossa dura, the motion is in ananterior-posterior plane.

  • 7/28/2019 Instrumentation in Neurosurgery

    41/101

    Drilled part should be in the form of a saucer

    rather than in the shape of cup

    It provides the neurosurgeon with increased visualization

    & working angles ,smaller potential space in which a

    10/18/2008 41instrumentation in neurosurgery

    pseudomeningocele can develop & decreases the sharp

    bony edge that may result in skin tightness and possible

    wound breakdown.

  • 7/28/2019 Instrumentation in Neurosurgery

    42/101

    Burr should always rotate away from the criticalstructures

    Choice of drill bit1) Cutting burrs work more efficiently when removing

    large amounts of bone

    2) Diamond burrs are used , ,

    critical neurovascular structures.

    -for hemostasis when used briefly without irrigation

    at a site of bleeding.

    3) The size of the drill to use the biggest one the workingspace safely allows

    10/18/2008 42instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    43/101

    10/18/2008 43instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    44/101

    10/18/2008 44instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    45/101

    10/18/2008 45instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    46/101

    10/18/2008 46instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    47/101

    10/18/2008 47instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    48/101

    Acorn, Cylinder Ball Tapered Match Head

    10/18/2008 48instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    49/101

    10/18/2008 49instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    50/101

    Craniotomy

    Correction of craniosynostosis,

    craniofacial anomalies

    ,

    Foraminotomy

    removal of osteophytes,iliac crest grafting etc.

    Excision of odontoid in TOO

    Removal of ACP

    10/18/2008 50instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    51/101

    Direct penetrating injury

    Transmission of heat

    magnetic imaging metal artifacts

    Noise pollution

    Transmission of prion diseases

    10/18/2008 51instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    52/101

    More powerful than pneumatic

    Improved overall system weight and balance -

    cable lighter, more flexible than pneumatic hose

    Reversible direction a e es gn preven s ncorrec connec on an

    assembly

  • 7/28/2019 Instrumentation in Neurosurgery

    53/101

    Adequate exposure of the target organ

    represents a laudable prerequisite of every

    successful operation.

    Hand held

    Self retaining

    10/18/2008 53instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    54/101

    Disadvantages:

    Slipping from the desired positionExcessive retracion

    Obscuring vision and light

    Inability to maintain in same position forlong time

    10/18/2008 54instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    55/101

    Dural Retractors

    10/18/2008 55instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    56/101

    10/18/2008 56instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    57/101

    10/18/2008 57instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    58/101

    10/18/2008 58instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    59/101

    10/18/2008 59instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    60/101

    10/18/2008 60instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    61/101

    Mechanical retractor mounts for neurosurgery,in

    1930s

    Earliest skull mounted system (Demartel,Malis,

    Heifetz,edinburgh,hamby etc.)mounted on burrhole,craniotomy edge

    Inadequate bone strength,obscuration of the field

    Soft tissue/muscle mounted and pillar and postdevices ( house and urban,weitlaner)

    less stable, less flexible

    10/18/2008 instrumentation in neurosurgery 61

  • 7/28/2019 Instrumentation in Neurosurgery

    62/101

    Skull mounted flexbar devices (Dohn andCarton,Apfelbaum) especially useful in

    Posterior fossa surgery

    Leyla retractor,Yasar gill

    adjustment difficulties,extreme

    length of the flexible arms

    Table mounted flexbar devices

    modification by yasargill and fox

    Kanshepolsky,U shaped bar

    * head or retractor movement independent ofeach other

    10/18/2008 instrumentation in neurosurgery 62

  • 7/28/2019 Instrumentation in Neurosurgery

    63/101

    Headrest mounted flexbar system

    sugita,Greenberg,

    Fukushima and Sano ,4 arms on clampsecure o may e ea res

    10/18/2008 instrumentation in neurosurgery 63

  • 7/28/2019 Instrumentation in Neurosurgery

    64/101

    10/18/2008 64instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    65/101

    10/18/2008 65instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    66/101

    10/18/2008 66instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    67/101

    10/18/2008 67instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    68/101

    10/18/2008 instrumentation in neurosurgery 68

  • 7/28/2019 Instrumentation in Neurosurgery

    69/101

    Yasargil

    Self retaining,no assistance needed

    Uniform hoding,no pressre irritations Upto 5 flexible arms can be used

    simultaneosly

    No obstruction to operative vision

    No restriction of operating area critical

    when using microscope

    10/18/2008 69instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    70/101

    10/18/2008 instrumentation in neurosurgery 70

  • 7/28/2019 Instrumentation in Neurosurgery

    71/101

    Fixing rod

    10/18/2008 instrumentation in neurosurgery 71

    coupler

  • 7/28/2019 Instrumentation in Neurosurgery

    72/101

    10/18/2008 instrumentation in neurosurgery 72

    Flexible arm

    spatula

  • 7/28/2019 Instrumentation in Neurosurgery

    73/101

    10/18/2008 instrumentation in neurosurgery 73

  • 7/28/2019 Instrumentation in Neurosurgery

    74/101

    Advantages: unique fixation clamp allows unlimitedpositioning of the retractor arm along the body of

    the retractor

    Attaches to virtually all self-retaining retractors Two retractor blade supports are available,allowing the use of both flat and round shaft

    retractor blades Provide improved exposure on Posterior FossaCraniotomies Excellent for nerve root retraction duringlaminectomy procedures

    10/18/2008 instrumentation in neurosurgery 74

  • 7/28/2019 Instrumentation in Neurosurgery

    75/101

    10/18/2008 instrumentation in neurosurgery 75

  • 7/28/2019 Instrumentation in Neurosurgery

    76/101

    10/18/2008 instrumentation in neurosurgery 76

  • 7/28/2019 Instrumentation in Neurosurgery

    77/101

    10/18/2008 instrumentation in neurosurgery 77

  • 7/28/2019 Instrumentation in Neurosurgery

    78/101

    10/18/2008 instrumentation in neurosurgery 78

  • 7/28/2019 Instrumentation in Neurosurgery

    79/101

    10/18/2008 instrumentation in neurosurgery 79

    Lumbr retraction handle

  • 7/28/2019 Instrumentation in Neurosurgery

    80/101

    10/18/2008 80instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    81/101

    10/18/2008 instrumentation in neurosurgery 81

  • 7/28/2019 Instrumentation in Neurosurgery

    82/101

    Designed for posterior thoracolumbar surgeries

    10/18/2008 instrumentation in neurosurgery 82

  • 7/28/2019 Instrumentation in Neurosurgery

    83/101

    10/18/2008 instrumentation in neurosurgery 83

    Provides simple, multi-directional exposure for a broad range ofsurgical procedures

  • 7/28/2019 Instrumentation in Neurosurgery

    84/101

    10/18/2008 instrumentation in neurosurgery 84

    * Capacity to simultaneously manipulate the spinal cord

  • 7/28/2019 Instrumentation in Neurosurgery

    85/101

    The incidence of contusion or infarction

    from overzealous brain retraction is

    probably 10% in cranial base procedures

    procedures.

    Brain retraction injury is caused by focal

    pressure (the retractor blade) on the brainleading to

    1) Reduction or cessation of local

    perfusion

    10/18/2008 instrumentation in neurosurgery 85

  • 7/28/2019 Instrumentation in Neurosurgery

    86/101

    Depends upon

    1.shape

    2. number of the retractors

    .

    4. duration of the retraction

    The retraction pressures used are usually

    in the range of 20 to 40 mm Hg use of two small retractor blades may

    provide exposure equivalent to one largeblade with a lower retraction pressure

    10/18/2008 instrumentation in neurosurgery 86

  • 7/28/2019 Instrumentation in Neurosurgery

    87/101

    Constant pressure Constant exposure

    readjusting the retractor

    blade as necessary to

    keep the pressure

    constant ,this type of retraction

    is naturally suited to

    retraction pressure

    monitoring

    setting the retractor

    blade once without

    further adjustment.

    The brain is allowedto adjust over time to

    the fixed retractor

    blade10/18/2008 instrumentation in neurosurgery 87

  • 7/28/2019 Instrumentation in Neurosurgery

    88/101

    10/18/2008 instrumentation in neurosurgery 88

  • 7/28/2019 Instrumentation in Neurosurgery

    89/101

    10/18/2008 instrumentation in neurosurgery 89

  • 7/28/2019 Instrumentation in Neurosurgery

    90/101

    10/18/2008 instrumentation in neurosurgery 90

  • 7/28/2019 Instrumentation in Neurosurgery

    91/101

  • 7/28/2019 Instrumentation in Neurosurgery

    92/101

    The original ultrasonic aspirator was developed in1947 for the removal of dental plaques.

    field of eye surgery in 1967 ,based on the principle

    of phaco-emulsification.

    First devoloped in 1976 in the US

    Suction device with a tip that vibrates at ultrasonicspeed

    Sonic energy disrupts and fragments

    Diluted and aspirated10/18/2008 92instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    93/101

    A console and handpiece

    Console has the ultrasonic generator- 2 typeselectrostriction, magnetostriction

    piezoelectric

    ceramic crystals

    change in dimensions of a

    magnetostrictive transducer

    Titanium tip vibrates longitudinally at a speed of23 to 35 khz ,

    amplitude of 100 300 microns ,function ofsetting the vibration level

    small amplitude - disruptive effect restricted to

    crystals decay not subject to decay

    10/18/2008 93instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    94/101

    Hand piece,

    stright vs Angled

    short Vs Long

    different frequencies

    Irrigation system

    to suspend the fragmentaed tissue, tocool the transducer and to prevent the blockage

    of suction system

    10/18/2008 94instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    95/101

    Simultaneouly fragment,emulsify and aspirate

    parenchymal tissue rapidly

    Vacuum effect

    Cavitation

    Rupture

    Susceptibility depends upon-

    water contentsensitivity to vibration

    Fat and brain easily disrupts Vs vessel and nerves

    10/18/2008 95instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    96/101

    Tissues with weak intracellular bonds,

    such as tumors and lipomas, are easy to

    fragment, whereas tissues with strong

    ,vessel walls, are difficult to fragment

    10/18/2008 96instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    97/101

    Low frequency high amplitude

    Useful in hard and partially calcified

    tumors

    Hi h fre uenc low am litudeuseful while working near vital structure

    adjustments of the vibration energy,irrigation

    rates and the suction pressures along with the

    use of appropriate hand piece optimizes the use

    10/18/2008 97instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    98/101

    Minimizes,

    mechanical manipulation

    Traction on adjascent tissue

    Clear and less crowded operative field

    Vs laser UA are faster ,good visualization of

    tumor brain interphase. Laser is more precise Suitable for HPE as they are not significantly

    distorted

    10/18/2008 98instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    99/101

    Penetrating injury

    ? Transmission of ultrasonic energy toa ascen v a s ruc ures rog one

    Reports of multiple cranial nerve palsies

    10/18/2008 99instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    100/101

    10/18/2008 100instrumentation in neurosurgery

  • 7/28/2019 Instrumentation in Neurosurgery

    101/101