installation.pdf
TRANSCRIPT
![Page 1: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/1.jpg)
ED 05 3DB 06687 DAAA 1/178
7 - 8 - 13 - 15 - 18 - 23 - 25 - 28 - 38 GHz
Short-Haul Low/Medium Capacity Digital Microwave Radio Links
ALCATEL 9400 AWY Rel.2.0 Installation Handbook
![Page 2: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/2.jpg)
ED 05 3DB 06687 DAAA 2/178
TABLE OF CONTENTS
1. HANDBOOK GUIDE.................................................................................................................................8 1.1. Copyright notification.............................................................................................................................8 1.2. Notice ....................................................................................................................................................8 1.3. 9400AWY Rel.2.0 Customer Documentation set..................................................................................8 1.4. History, applicability and purpose of this manual................................................................................10 1.5. Handbook history, scope and related documents...............................................................................11
2. SYSTEM TECHNICAL CHARACTERISTICS ........................................................................................12 2.1. System temperature condition tolerated .............................................................................................12 2.2. System Voltage working condition ......................................................................................................12 2.3. System Mechanical characteristics .....................................................................................................13
3. INSTALLATION RULES.........................................................................................................................14 3.1. Safety Rules ........................................................................................................................................14 3.2. General Rules .....................................................................................................................................14 3.3. EMF safety instructions.......................................................................................................................15 3.4. Unpacking and Warehousing ..............................................................................................................16
3.4.1. General .......................................................................................................................................16 3.4.2. Unpacking...................................................................................................................................16 3.4.3. Warehousing ..............................................................................................................................17
3.5. Pre-Installation Checking ....................................................................................................................17 3.5.1. 1+0 Integrated Antenna.............................................................................................................17 3.5.2. 1+0 NON Integrated Antenna....................................................................................................17 3.5.3. 1+1 Integrated Antenna..............................................................................................................18 3.5.4. 1+1 NON Integrated Antenna.....................................................................................................18 3.5.5. OUTDOOR UNITS CHECK........................................................................................................19 3.5.6. RF COUPLER UNIT CHECK .....................................................................................................22 3.5.7. INDOOR UNIT TYPES CHECK .................................................................................................25 3.5.8. INTEGRATED POLE MOUNTING INSTALLATION HARDWARE KIT CHECK........................27 3.5.9. NON INTEGRATED ANTENNA POLE MOUNTING INSTALLATION HARDWARE KIT CHECK 31
3.6. Installation Tools required ...................................................................................................................35 3.7. Tables of installation IDU-ODU components ......................................................................................35
3.7.1. Integrated or Not Integrated antenna installation components ..................................................35 3.7.2. IDU installation components.......................................................................................................45
4. OUTDOOR UNITS INSTALLATION (ODU) ...........................................................................................47 4.1. General................................................................................................................................................47 4.2. TRANSCEIVER (A-box) and BRANCHING (D-box) boxes coupling..................................................49 4.3. Typical installation layout ....................................................................................................................50 4.4. 1+0 ODU configuration Installation with integrated antenna...............................................................55
4.4.1. Required Parts............................................................................................................................55 4.4.2. Pole mounting assembly ............................................................................................................55 4.4.3. General Procedural Sequence: ..................................................................................................58 4.4.4. Procedure note ...........................................................................................................................58 4.4.5. Installing the “pole mounting“ on mast .......................................................................................58 4.4.6. Installing the antenna on the pole mounting...............................................................................59 4.4.7. Installing the ODU ......................................................................................................................60 4.4.8. Pointing the antenna...................................................................................................................61 4.4.9. Installation on the wall information .............................................................................................64 4.4.10. Antenna 3 / 4 Feet Installation Instructions ................................................................................65
4.5. 13-38GHz - 1+1 ODU configuration Installation with integrated antenna...........................................67 4.5.1. Required Parts Listing ................................................................................................................67 4.5.2. 13-38GHz - 1+1 Typical installation (General Procedural Sequence) .......................................68 4.5.3. 13-38GHz Change polarization in 1+1 configuration .................................................................70
4.6. 7- 8GHz 1+1 ODU configuration Installation with integrated antenna (Alternative A) .......................72 4.6.1. Required Parts Listing ................................................................................................................72 4.6.2. 7- 8GHz 1+1 Typical installation (General Procedural Sequence) ............................................73 4.6.3. 7- 8GHz Change polarization in 1+1 configuration ....................................................................75
4.7. 7- 8GHz 1+1 ODU configuration Installation with integrated antenna (Alternative B) .......................76 4.7.1. Required Parts Listing ................................................................................................................76
![Page 3: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/3.jpg)
ED 05 3DB 06687 DAAA 3/178
4.7.2. 7- 8GHz 1+1 Typical installation (General Procedure Sequence) .............................................77 4.8. 1+0 ODU configuration Installation with non-integrated antenna........................................................80
4.8.1. Required Parts Listing ................................................................................................................80 4.8.2. General Procedural Sequence ...................................................................................................80 4.8.3. Install the pole mounting on the mast.........................................................................................81 4.8.4. Installing the ODU.......................................................................................................................82 4.8.5. Installing the “Flextwist“ waveguide............................................................................................83
4.9. 13-38GHz - 1+1 ODU configuration Installation with non-integrated antenna...................................84 4.9.1. Required Parts Listing ................................................................................................................84 4.9.2. General Procedural Sequence ...................................................................................................84 4.9.3. Installing the Coupler ..................................................................................................................85
4.10. 7- 8GHz - 1+1 ODU configuration Installation with non-integrated antenna (Alternative A)..............86 4.10.1. Required Parts Listing ................................................................................................................87 4.10.2. General Procedural Sequence ...................................................................................................87 4.10.3. Installing the Coupler ..................................................................................................................87
4.11. 7-8GHz – Installation Full Indoor AWY (Two Terminal) ......................................................................90 Table 17 - AWY 7/8 GHz Installation code Full Indoor housing kit ..............................................................93 4.12. 7- 8GHz - 1+1 ODU configuration Installation with non-integrated antenna (Alternative B)..............94
4.12.1. Required Parts Listing ................................................................................................................94 4.12.2. General Procedural Sequence ...................................................................................................94 4.12.3. Installing the Coupler ..................................................................................................................95
4.13. Solar shield Installation........................................................................................................................97 4.14. IDU / ODU cable grounding kit assembling.........................................................................................98
5. INDOOR UNITS INSTALLATION (IDU) ..............................................................................................100 5.1. General..............................................................................................................................................100 5.2. Rack mount kit description ................................................................................................................100
5.2.1. Rack mount installation in ETSI (WTD) and North American standard rack............................100 5.2.2. Laborack ...................................................................................................................................104 5.2.3. Rack mount adapters installation in a rack...............................................................................105 5.2.4. Grounding of the subrack .........................................................................................................106
5.3. Minimum distances between systems installed in the rack...............................................................107 5.4. Wall mounting kit description.............................................................................................................109
6. IDU INTERCONNECTIONS ..................................................................................................................110 6.1. Module interconnections, description ................................................................................................110
6.1.1. IDU – ODU cable disconnection/connection ............................................................................111 6.2. Numbering and functions referred to the Connection Points ............................................................117 6.3. Summary and type connectors usage...............................................................................................120 6.4. Suggested cabling .............................................................................................................................121
6.4.1. Split Cable.................................................................................................................................122 6.4.2. Inter- connection Main – Extension flat cable...........................................................................124 6.4.3. I/O 1 through 8 and I/O 9 through 16........................................................................................125 6.4.4. Mini Distributor connection .......................................................................................................127 6.4.5. NMS V11 - AUDIO 1 (EOW).....................................................................................................128 6.4.6. NMS G703 + Audio 2 (EOW)....................................................................................................129 6.4.7. NMS INTERFACE AWY-MELODIE..........................................................................................130 6.4.8. Service Channel........................................................................................................................131 6.4.9. Housekeeping Alarms...............................................................................................................132 6.4.10. E3 - DS3 ...................................................................................................................................133 6.4.11. M, LT, LEDs (housekeeping, Summarizing).............................................................................134 6.4.12. OS – DEBUG............................................................................................................................135 6.4.13. CT access .................................................................................................................................136 6.4.14. R - Reset pushbutton................................................................................................................136 6.4.15. TPH – Telephone Handset .......................................................................................................137 6.4.16. IDU – ODU connections ..........................................................................................................138 6.4.17. 50 Ohms connector assembling ...............................................................................................139 6.4.18. Power Supply connector, On / Off switch .................................................................................141 6.4.19. ON-OFF switch .........................................................................................................................142
7. CAPACITY EXTENSION.......................................................................................................................143 ANNEXES ......................................................................................................................................................144 ANNEX A CABLE CODE INTERCONNECTIONS DESCRIPTION..........................................................152
A.1. Cable 3CC52130AAAA (L.= 1.6m) or 3CC52131AAAA (L.= 6.4m)..................................................166 ANNEX B NETWORK INTERCONNECTIONS.........................................................................................167
B.1.1. NMS Continuity .........................................................................................................................167
![Page 4: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/4.jpg)
ED 05 3DB 06687 DAAA 4/178
B.2. AWY-MELODIE SNMP Interconnections Cable list.........................................................................172
![Page 5: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/5.jpg)
ED 05 3DB 06687 DAAA 5/178
LIST OF FIGURES
Tables Table 1 - ODU Mounting Hardware Installation Kit Listing (3CC10752ABAA) ................................................28 Table 2 - ODU Mounting Hardware Installation Kit Listing (3CC10752ABAB) ................................................29 Table 3 – Cable Grounding Kit .........................................................................................................................30 Table 4 – Non Integrated pole mounting installation kit ...................................................................................33 Table 5 – Cable Grounding Kit .........................................................................................................................33 Table 6 – 9470 AWY - ODU Installation materials for Integrated or Non Integrated antenna cases...............37 Table 7 – 9413 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases................38 Table 8 – 9415 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases................39 Table 9 – 9418 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases................40 Table 10 – 9423 AWY - ODU Installation materials for Integrated or Not Integrated antenna case................41 Table 11 – 9425 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases..............42 Table 12 – 9428 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases..............43 Table 13 – 9438 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases..............44 Table 14 - IDU Installation components ...........................................................................................................45 Table 15 - 7-8Ghz FLEXTWIST WAVEGUIDE ................................................................................................83 Table 16 - 13-38Ghz FLEXTWIST WAVEGUIDE ............................................................................................83 Table 17 - AWY 7/8 GHz Installation code Full Indoor housing kit ..................................................................93 Table 18 - Numbering and functions referred to the Connection Points (Main).............................................117 Table 19 - Numbering and functions referred to the Connection Points (Extension).....................................118 Table 20 - Numbering and functions referred to the Connection Points (1+1 version)..................................119 Table 21 - Suggested cabling.........................................................................................................................121 Table 22 - I/O (1 through 8) connections........................................................................................................126 Table 23 - I/O (9 through 16) connection .......................................................................................................126 Table 24 – Distributor Subrack and Cable type..............................................................................................127
Figures Figure 1 – ODU 13-38 GHz rear and front views .............................................................................................19 Figure 2 - ODU 7-8 GHz rear and front views..................................................................................................19 Figure 3 - ODU solar shields views (13 to 38GHz) ..........................................................................................20 Figure 4 - ODU solar shields views (7- 8GHz) .................................................................................................21 Figure 5 - ODU RF coupler view (Bands from 13 to 38 GHz) ........................................................................22 Figure 6 - ODU RF coupler view (Bands 7- 8 GHz) ........................................................................................23 Figure 7 - ODU RF coupler view (Bands 7- 8 GHz) ........................................................................................24 Figure 8 - IDU 9400 AWY 1+0.........................................................................................................................25 Figure 9 - IDU 9400 AWY 1+1.........................................................................................................................25 Figure 10 - Telephone set ...............................................................................................................................26 Figure 11 – Not integrated antenna and ODU Mounting Hardware Installation Kit .........................................32 Figure 12...........................................................................................................................................................32 Figure 13 – Integrated POLE MOUNTING View..............................................................................................34 Figure 14 – RADIO and NON Integrated ANTENNA CABINET GROUNDING KIT View ...............................34 Figure 15 - 13-38GHz ODU rear and front views.............................................................................................47 Figure 16 – 7-8 GHz ODU rear and front views ...............................................................................................48 Figure 17 – D-BOX and A-BOX Integration......................................................................................................49 Figure 18 - Typical installation of 1+0 ODU with integrated antenna, 30 cm or 60 cm....................................51 Figure 19 - Typical installation of 1+1 ODU with integrated antenna, 30 cm or 60 cm....................................52 Figure 20 - Typical install. of 1+0 ODU with non integrated antenna and the 600 mm. ..................................53 Figure 21 - Typical install. of 1+1 ODU with non integrated antenna and the 600 mm. flexible twist or
optimized Wave-guide length ..................................................................................................................54 Figure 22 - Integrated pole mounting with ODU 1+0, Horizontal Polarization .................................................55 Figure 23 - Integrated antenna pole mounting with ODU 1+0, Vertical Polarization .......................................56 Figure 24 – 7-8 GHz Integrated antenna pole mounting with ODU 1+0, Vertical Polarization ........................57 Figure 25 - Pole mounting installation for integrated antenna..........................................................................58 Figure 26 - Change polarisation description.....................................................................................................59 Figure 27 - Installation with integrated antenna and Vertical polarization........................................................59 Figure 28 - ODU 1+0 installation for integrated antenna..................................................................................60 Figure 29 – Pole mounting types......................................................................................................................61 Figure 30 – Stretching screw (3CC14292AAAA) ............................................................................................61 Figure 31 – Pole mounting without Stretching screw inserted ........................................................................62
![Page 6: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/6.jpg)
ED 05 3DB 06687 DAAA 6/178
Figure 32 – Stretching screw inserted (Vertical alignment) .............................................................................62 Figure 33 – Integrated pole mounting (Horizontal alignment).........................................................................63 Figure 34 - Pole mounting near a wall .............................................................................................................64 Figure 35 – 3 Feet Antenna (Configuration 1+0) .............................................................................................65 Figure 36- 4 Feet Antenna (Configuration 1+0) ...............................................................................................66 Figure 37 - Typical installation pole mounting with ODU 1+1 for integrated antenna......................................67 Figure 38 - Installing the Coupler To the Radio Support..................................................................................68 Figure 39 - Installing the RF coupler with ODU 1+1 for integrated antenna....................................................69 Figure 40 – 1st Step and 2nd step .....................................................................................................................70 Figure 41 – 1st Step inserted ..........................................................................................................................70 Figure 42 – 2nd Step inserted ..........................................................................................................................71 Figure 43 – Screws fixing.................................................................................................................................71 Figure 44 - Typical installation pole mounting with ODU 1+1 for integrated antenna (7-8GHz)......................72 Figure 45 - Installing the Coupler To the Radio Support..................................................................................73 Figure 46 - Installing the RF coupler with ODU 1+1 for integrated antenna....................................................74 Figure 47 – 7 – 8GHz Change Polarization .....................................................................................................75 Figure 48 - Typical installation pole mounting with ODU 1+1 for integrated antenna (7-8GHz)......................76 Figure 49 – 7- 8GHz Coupler (Alternative B) ...................................................................................................77 Figure 50 - Installing the Coupler To the Radio Support..................................................................................77 Figure 51 - Installing the RF coupler with ODU 1+1 for integrated antenna....................................................78 Figure 52 – 7 – 8GHz Change Polarization .....................................................................................................79 Figure 53 - Pole mounting installation for not integrated antenna with ODU 1+0............................................80 Figure 54 - Installation of the pole mounting for not integrated antenna .........................................................81 Figure 55 - ODU 1+0 installation for not integrated antenna ...........................................................................82 Figure 56 - Pole mounting with ODU 1+1 for not integrated antenna (13 to 38 GHz) .....................................84 Figure 57 - Installation of the Coupler on the pole mounting (13 to 38 GHz) ..................................................85 Figure 58 - Installation of ODU 1+1 on the pole mounting for not integrated antenna (11 to 38 GHz) ...........85 Figure 59 - Pole mounting ODU 1+1 for not integrated antenna .....................................................................86 Figure 60 - Pole mounting ODU 1+1 for not integrated antenna .....................................................................86 Figure 61 - Pole mounting/RF COUPLER 1+1 for not integrated antenna (7 - 8GHz)....................................88 Figure 62 - Installation of ODU 1+1 on the pole mounting for not integrated antenna (7- 8 GHz) ..................89 Figure 63 – Panel support 4U – 19“ for ODU 1+1 and Coupler.......................................................................90 Figure 64 – Panel support 4U – 19“ for ODU 1+1 and Coupler.......................................................................91 Figure 65 – Principle Installation in Laborack with ODU 1+1 and Coupler......................................................92 Figure 66 – Support pole mounting (Laborack) ...............................................................................................93 Figure 67 - Pole mounting ODU 1+1 for not integrated antenna (7 - 8GHz) ...................................................94 Figure 68 - Pole mounting/RF COUPLER 1+1 for not integrated antenna (7 - 8GHz)....................................95 Figure 69 - Installation of ODU 1+1 on the pole mounting for not integrated antenna (7- 8 GHz) ..................96 Figure 70 - Solar shield installation ODU 1+0..................................................................................................97 Figure 71 - Example of 1+0 and 1+1 IDU with 21" supports for rack mounting.............................................101 Figure 72 - Subrack installation in 21" rack....................................................................................................102 Figure 73 –View of installation .......................................................................................................................103 Figure 74 - Wired mini distributor ...................................................................................................................103 Figure 75 - Laborack ......................................................................................................................................104 Figure 76 - IDU adapter for installation ..........................................................................................................105 Figure 77 - Subrack cabinets grounding points .............................................................................................106 Figure 78 - Minimum distances for dense packing in both systems (1+0 and 1+1) ......................................108 Figure 79 – Summary of minimum distance in 1+0 and 1+1 configuration....................................................108 Figure 80 - Fixing the mechanical support to the wall....................................................................................109 Figure 81 – Main Unit Front ...........................................................................................................................110 Figure 82 –Extension Unit Front ....................................................................................................................110 Figure 83 - Main Front / Rear view interconnections IDU.............................................................................112 Figure 84 – Main Rear view (Flash card insertion) .......................................................................................112 Figure 85 - Extension Front view interconnections IDU.................................................................................113 Figure 86 - Extension Rear view IDU.............................................................................................................113 Figure 87 – 1+0 Interconnections view ..........................................................................................................114 Figure 88 – 1+1 Interconnection view (8E1) ..................................................................................................115 Figure 89 – 1+1 Interconnection view (16E1) ................................................................................................115 Figure 90 – Interconnection view (E3) ...........................................................................................................116 Figure 91 – Interconnection view (Ethernet ...................................................................................................116 Figure 92 – E1 / DS1 and User Service Channel Split-Cable........................................................................122 Figure 93 – Cable connections (example) .....................................................................................................123 Figure 94-1+1 Inter-connection......................................................................................................................124 Figure 95 - I/O 1 through 8 and 9 through16 connections (Main – Extension)..............................................125 Figure 96 - NMS V11 – Audio1 (EOW) connections......................................................................................128 Figure 97 - NMS_G703 + Audio2 (EOW) connections ..................................................................................129
![Page 7: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/7.jpg)
ED 05 3DB 06687 DAAA 7/178
Figure 98 – NMS INTERFACE AWY-MELODIE ............................................................................................130 Figure 99 - SERVICE CHANNEL connections (Main – Extension)................................................................131 Figure 100 - Housekeeping- Alarms- connections .........................................................................................132 Figure 101 - E3 DS3 Interface connections (Main – Extension) ....................................................................133 Figure 102 - M, LT and LEDs meanings ........................................................................................................134 Figure 103 – OS - DEBUG connections cable pin out table ..........................................................................135 Figure 104 - CT connections ..........................................................................................................................136 Figure 105 - IDU ODU interconnections (Main – Extension) .........................................................................138 Figure 106 - Details for assembling “N” connector to coaxial cable...............................................................139 Figure 107 – Power Supply Connector ..........................................................................................................141 Figure 108 - Power supply connections .........................................................................................................142 Figure 109 – ON-OFF Switch.........................................................................................................................142 Figure 110 - Fixing the W.T.D. rack using expansion anchors ......................................................................145 Figure 111 - rack - Drill Holes for Anchoring to the Floor (single rack) ..........................................................146 Figure 112 - rack - Floor tile drilling template .................................................................................................147 Figure 113 - rack - Example of securing rack assembly to computer floor ....................................................148 Figure 114 - rack - T.R.U. fastening to the rack .............................................................................................149 Figure 115 - W.T.D rack - Front plate 6 circuit breakers ................................................................................149 Figure 116 - Rack - Ground connections .......................................................................................................150
![Page 8: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/8.jpg)
ED 05 3DB 06687 DAAA 8/178
1. HANDBOOK GUIDE
1.1. Copyright notification The technical information of this manual is property of ALCATEL and must not be copied, reproduced or disclosed to a third party without written consent.
1.2. Notice The product specification and/or performance levels contained in this document are for information purposes only and are subject to change without notice. They do not represent any obligation on the part of ALCATEL.
1.3. 9400AWY Rel.2.0 Customer Documentation set
The standard Customer Documentation for 9400AWY Rel.2.0 is in the English language and is distributed to Customers only by the following CD-ROM:
CD-ROM Technical Description Technical Code Commercial Code DCP 9400AWY 2.0 CD_ROM 3DB 06687 AAAA 3EJ 14535 AAAA
It contains, in electronic format (ADOBE ACROBAT pdf files), the following handbooks:
- 9400AWY Rel.2.0 Installation Handbook (this handbook) (V2.0.0 to V2.0.4) Provides information regarding equipment hardware installation, according to Alcatel WTD LAB. rules. - 9400AWY Rel.2.0 User Manual (V2.0.4 only)
Provides information regarding 9400AWY Rel.2.0 running with SWP 9400AWY IDU16 V2.0.4 & TCO Suite: - equipment description and composition, station layouts and hardware setting documentation and
maintenance - SWP screens and operational procedures for Equipment SW management and maintenance - equipment commissioning, according to Alcatel WTD LAB rules
- 9400AWY Rel.2.0 TRS and SAT (V2.0.4 only)
Contains the Test Report Sheet and the Site Acceptance Test protocol, according to Alcatel WTD LAB rules. The source file of this document (MSWORD 2000) is also distributed in the Documentation CD-ROM
- 9400AWY Rel.2.0 Line-up Guide (V2.0.0 to V2.0.3) Provides information regarding equipment line up and commissioning, according to Alcatel WTD LAB.
rules.
- 9400AWY Rel. 2.0 Technical Handbook (V2.0.0 to V2.0.3) Provides detailed information regarding 9400AWY equipment description, composition and
provisioning, station layouts, item technical and commercial codes, and maintenance procedures.
- 9400AWY Rel.2.0 SWP 2.0 CT Operator’s Handbook (V2.0.0 to V2.0.3) Provides 9400AWY SWP screens and operational procedures for equipment SW management and
maintenance.
- Interference investigation procedure (Version independent) Describes the measurement procedure for the interference searching in the various RF bands used by
Alcatel Radio Transmission products. It is common to all Alcatel Radio Transmission products.
![Page 9: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/9.jpg)
ED 05 3DB 06687 DAAA 9/178
For further information regarding 9400AWY Rel.2.0 Customer Documentation set, please refer to the document Customer Documentation set description and CD-ROM history accessible from the CD-ROM MAIN MENU.
![Page 10: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/10.jpg)
ED 05 3DB 06687 DAAA 10/178
1.4. History, applicability and purpose of this manual
05 08/11/2006 00000 34899 P.GAROFOLI C.NAVA
04 24/05/2006 00000 33338 P.GAROFOLI C.NAVA
03 03/02/2006 00000 20169 P.GAROFOLI C.NAVA
02 09/11/2005 00000 23752 A.BESTETTI C.NAVA
01 24/05/2005 R.VALTOLINA C.NAVA
ED DATE CHANGE NOTE APPRAISAL AUTHORITY
ORIIGINATOR
This handbook is associated to SWP 9400AWY Rel.2.0.x, taking into account all system features that are made available by first SWP version V2.0.0, as well as by successive SWP releases-versions. This table sums-up the major additional features (mainly related to new HW items and relevant performance) that are available starting from a certain SWP-version successive to first SWP version V2.0.0.
Additional feature Available from
SWP-version New 48/60V and 24V PSU ETSI IDU Main and Extension units, with different ’3DB xxxxx AX**’ P/N ( with X > A ) (refer to Technical Handbook for details)
mandatory from V2.0.1
7-8 GHz ODUs (new 9470AWY product) N.B.
New full-range (24-60V) IDU Main and Extension units N.B.
V2.0.2
ANSI version (DS1/DS3) interfaces and relevant ANSI IDU Main and Extension units and Plug-Ins N.B. ANSI version ODUs N.B.
• New 13–38 GHz ODUs with variable shifter N.B. Refer to Technical Handbook from ED.04 for details • Removed functionality restrictions of the Remote Craft Terminal in
OSPF Stub areas • Possibility of configuring a Default Gateway Routing Refer to Operator’s Handbook from ED.04 or User Manual for details
V2.0.3
ODU 32E1
V2.0.4
N.B. the claimed item management must be meant from SWP-version point of view, independently from actual availability of related HW items. Refer to User Manual/Technical Handbook for details.
WARNING Ed.05 of this handbook is validated in conjunction with SWP versions V2.0.0 to V2.0.4 only. Information relevant to SWP versions > V2.0.4, if any, must be considered preliminary, subject to change and without any obligation on the part of ALCATEL.
![Page 11: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/11.jpg)
ED 05 3DB 06687 DAAA 11/178
1.5. Handbook history, scope and related documents
ED DATE COMMENTS
01 24/05/2005 First Edition for R2.0.0
02 09/11/2005 Second Edition for R2.0.0 to R.2.0.1, and corrections.
03 03/02/2006 Third Edition for R2.0.0 to R.2.0.2, and corrections.
04 24/05/2006
Draft editions neither validated nor officially released issue, for internal validation purposes: • 21/04/2006 : ED04A First draft edition Fourth Edition for R2.0.0 to R.2.0.3, and corrections.
05 08/11/2006
Draft editions neither validated nor officially released issue, for internal validation purposes: • ED05A First draft edition Fifth Edition for R2.0.0 to R.2.0.4, and corrections
The scope of this document is to provide the user with the information needed to install the hardware components of an equipment of the 9400AWY Rel.2.0 family: • mechanical installation of the INDOOR and OUTDOOR units • mechanical installation and pre-positioning of the anntenna(s) • allocation (but not the connection) of the IDU-ODU IF cable.
Notice that the subsequent operations for the equipment activation are out of the scope of this document. For this purpose refer to the User Manual/Line-Up Guide.
Take into account that this handbook does not contain the following bits of information: • detailed equipment Technical Characteristics • item Commercial Codes • equipment description, at various levels • detailed safety instructions
that you can find in the User Manual/Technical Handbook.
To easily find such information, or any other information you may need (and that is not included in this handbook), please refer to the document Documentation Quick Guide accessible from the CD-ROM MAIN MENU.
![Page 12: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/12.jpg)
ED 05 3DB 06687 DAAA 12/178
2. SYSTEM TECHNICAL CHARACTERISTICS
2.1. System temperature condition tolerated
- Storage condition - ETS 300.019 class 1.3 - Transport condition - ETS 300.019 class 2.3 - Working condition - IDU - from -5°C to +55°C
- ODU - from -33°C to +55°C
2.2. System Voltage working condition
DC nominal voltage +/- 48 to +/- 60 Vdc +/-20% +/- 24 Vdc -20% +50% Polarity = + or – floating ( isolated ground) System Consumption Sys. 1+0 <=40W
Sys. 1+1 <=80W
![Page 13: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/13.jpg)
ED 05 3DB 06687 DAAA 13/178
2.3. System Mechanical characteristics
ODU weigth 3.9kg Dimension 235X 235X 72 mm IDU 1+0 weight 2.5 kg IDU 1+0 Dimension 44,45X 210X443 mm (1U) IDU 1+1 weight 4.0.kg IDU 1+1 Dimension 89,9X210X443 mm (2U)
Couplers dimensions and weight: Coupler 7-8Ghz 1AB228950005 weight 6kg Dimensions 521x235x121 mmm 1AB340390001 weight 6kg Dimensions 286,4x342,4x235 mm Coupler 13-38Ghz 3CC13474ABAA weight 4,3kg Dimensions 341x234x234 mm
For more information, please refer to the User Manual/Technical Handbook, chapters: • Technical Specifications • ODU and antenna configurations, part lists and provisioning, paragraph ODU mechanical design and
identification
![Page 14: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/14.jpg)
ED 05 3DB 06687 DAAA 14/178
3. INSTALLATION RULES
WHEN CARRYING OUT THE GIVEN OPERATIONS OBSERVE THE NORMS STATES IN RELATIVE CHAPTER IN USER MANUAL/ TECHNICAL HANDBOOK
3.1. Safety Rules
Detailed Safety Rules are given in User Manual/Technical Handbook’s. They describe the operations and/or precautions to observe to safeguard operating personnel during the working phases and to guarantee equipment safety. Please read them with accuracy before to start every action on the equipment.
3.2. General Rules
• Check that the equipment is operating with all the shields properly positioned (dummy covers, ESD connector protections, etc.)
• Carefully observe the front-panel warning labels prior to working on optical connections while the equipment is in-service
• In order to reduce the risk of damage the electrostatic sensitive devices, is mandatory to use the elasticized band (around the wrist) and the coiled cord joined connect with the ground rack during the touching of the equipment.
• All the measures must be done at the MDF/CDF points (MDF= Mini Distributor Frame, CDF= Customer Distributor Frame).
• The equipment may be installed only in “RESTRICTED ACCESS LOCATIONS”, and be permanently connected to a PROTECTIVE EARTHING CONDUCTOR as described in the Installation section.
Equipotential bonding must be applied for all equipments in the location.
ATTENTION EMC NORMS
SAFETY RULES
Carefully observe the front-panel warning labels prior to working on optical connections while the equipment is in-service.
![Page 15: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/15.jpg)
ED 05 3DB 06687 DAAA 15/178
3.3. EMF safety instructions
Equipment emitting RF power (Reminder from site preparation procedure):
- The site must be compliant with ICNIRP guidelines or local regulation if more restrictive.
- The following rules should be strictly applied by Customer:
• None authorized persons should not enter the compliance boundaries, if any, for the general public.
• Compliance RF boundaries, if any, related to Electro Magnetic Field exposure must be marked.
• Workers should be allowed to switch-off the power if they have to operate inside compliance boundaries.
• Assure good cable connection.
• Install the antenna as high as possible from floor or area with public access (if possible the cylinder delimitating the compliance boundaries, if any, or the cylinder corresponding to the transmission area directly in front of antenna with the same diameter as the antenna, more than 2 meters high).
• Install the antenna as far as possible from other existing equipment emitting RF power.
- Anyway remind that someone standing in front of the 9400AWY antenna may cause traffic shutdown
Place the relevant stickers:
EMF EMISSION
WARNING SIGN
On the site when applicable (when people can cross the compliance boundariesand/or the transmission area of the antenna, i.e. roof top installation) - Warning label «Do not stand on the antenna axis» On the mast (front side) - EMF emission warning sign (Yellow and black) to be placed at bottom of antenna, visible by someone moving in front of the antenna (roof top installation) On the antenna (rear side) - EMF emission warning sign, placed on the antenna.
![Page 16: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/16.jpg)
ED 05 3DB 06687 DAAA 16/178
3.4. Unpacking and Warehousing
3.4.1. General
The following procedures have been issued and must be observed when unpacking the equipment. The reciprocal operation must be done for repacking. In such case it is recommended to use the original packing material.
The following sturdy outer packing material is utilized in order to protect the equipment against mechanical and climatic stresses to which they are subjected: wooden crates for transport by ship, air, on road for periods longer than 60 days ply-wood crates for transport by ship, air, on road for periods of 30 to 60 days cardboard boxes for transport by air or on road for periods of less than 30 days
3.4.2. Unpacking
PRELIMINARY CHECKS
The following information should be printed on the outer crate: • International symbols
side up :
keep dry
fragile
• trade mark/address of the manufacturing company; • labels (or template marks) indicating information on the contract and destination site of the
product; • an envelope holding among others the packing list
Upon receipt check:
• that the final destination of the crates is that indicated on the label; • that no damage was made to the cases
Report any shipping damages to the Company’s representative or the Shipping Agent. UNPACKING
When having to unpack proceed as follows: • make sure that the packing has been properly positioned, refer to the symbol • open the case; • remove the shockproof material; • remove the goods from the case; • remove prepacking, the polyethylene bag and any other protection; • remove the plastic bags cello taped to the rack and containing accessories; • remove the dehydrating bags; • ascertain that the goods are not damaged and that they correspond to those indicated on the
packing list enclosed in the envelope. Conversely, contact the agency’s representative.
N.B. When unpacking it is advisable to handle the packing material with care; it might be reused for packing again if it must be reshipped.
![Page 17: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/17.jpg)
ED 05 3DB 06687 DAAA 17/178
3.4.3. Warehousing
If having to store the packed material, the following requirements must be met:
• the cardboard boxes must be placed indoor in airy rooms;
• the wooden or plywood cases can be placed outdoors provided they are protected against rain and direct sunlight.
3.5. Pre-Installation Checking CRATE CONTENTS CHECK
Check the contents of the shipping crates for the following configurations:
3.5.1. 1+0 Integrated Antenna
- IDU - BB 1+0 (Telephone Kit if present in site) - ODU – RTx & solar shield - Integrated Pole Mounting - Fixing Installation kit material - Antenna - IDU / ODU Cable & Connectors - Installation kit material - Subrack for BB Wall installation ( if foreseen by Plant Documentation) - Rx Power Monitoring & Light Service Kit Cable
3.5.2. 1+0 NON Integrated Antenna
- IDU - BB 1+0 (Telephone Kit if present in site) - ODU – RTx & solar shield - Non Integrated Pole Mounting - Antenna Support - Fixing Installation kit material - Antenna - Flex Twist / Wave guide and Wave Guide Connectors - IDU / ODU Cable & Connectors - Installation kit material - Subrack for BB Wall installation ( if foreseen by Plant Documentation ) - Rx Power Monitoring & Light Service Kit Cable
![Page 18: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/18.jpg)
ED 05 3DB 06687 DAAA 18/178
3.5.3. 1+1 Integrated Antenna
- IDU - BB 1+1 (Telephone Kit if present in site) - N°2 ODU – RTx & solar shield - RF Coupler - Integrated Pole Mounting - Fixing Installation kit material - Antenna - IDU / ODU Cable & Connectors - Installation kit material - Subrack for BB Wall installation ( if foreseen by Plant Documentation ) - Rx Power Monitoring & Light Service Kit Cable
3.5.4. 1+1 NON Integrated Antenna
- IDU - BB 1+1 (Telephone Kit if present in site) - Fixing Installation kit material - N°2 ODU – RTx & solar shield - RF Coupler - Non Integrated Pole Mounting - Antenna Support - Antenna - Flex Twist / Wave guide and Wave Guide Connectors - IDU / ODU Cable & Connectors - Installation kit material - Subrack for BB Wall Installation ( if foreseen by Plant Documentation )
- Rx Power Monitoring & Light Service Kit Cable
![Page 19: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/19.jpg)
ED 05 3DB 06687 DAAA 19/178
3.5.5. OUTDOOR UNITS CHECK
Figure 1 – ODU 13-38 GHz rear and front views
A-BOX
D-BOX
Figure 2 - ODU 7-8 GHz rear and front views
![Page 20: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/20.jpg)
ED 05 3DB 06687 DAAA 20/178
ODU Solar Shield P/N - 3CC13476AAAA
Screws
1+0 ODU solar shield view
1+1 ODU solar shields view
Figure 3 - ODU solar shields views (13 to 38GHz)
![Page 21: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/21.jpg)
ED 05 3DB 06687 DAAA 21/178
1+1 ODU solar shields view
Figure 4 - ODU solar shields views (7- 8GHz)
![Page 22: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/22.jpg)
ED 05 3DB 06687 DAAA 22/178
3.5.6. RF COUPLER UNIT CHECK
CH 1 Side
CH 0 Side
Figure 5 - ODU RF coupler view (Bands from 13 to 38 GHz)
![Page 23: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/23.jpg)
ED 05 3DB 06687 DAAA 23/178
Main Acess
Figure 6 - ODU RF coupler view (Bands 7- 8 GHz)
![Page 24: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/24.jpg)
ED 05 3DB 06687 DAAA 24/178
Figure 7 - ODU RF coupler view (Bands 7- 8 GHz)
MAIN
MAIN
![Page 25: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/25.jpg)
ED 05 3DB 06687 DAAA 25/178
ODU RF coupler Reference P/N
1AB228950005 7.1-8.5 GHz 10dB Coupler 1AB340390001 7.1-8.5 GHz 10dB Coupler
3CC13472ABAA 13/15 GHz 10dB Coupler
3CC13473ABAA 18/23/25 GHz 10dB Coupler
3CC13474ABAA 28/38 GHz 10dB Coupler
3.5.7. INDOOR UNIT TYPES CHECK
MAIN
Figure 8 - IDU 9400 AWY 1+0
MAIN
EXTENSION
Figure 9 - IDU 9400 AWY 1+1
![Page 26: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/26.jpg)
ED 05 3DB 06687 DAAA 26/178
(Telephone – 3CC07946AAAA)
(Telephone – 1AF12831AAAA)
Figure 10 - Telephone set
RJ 11 connector
Set switch to DTMF
ON/OFF switch
RJ11 connector
![Page 27: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/27.jpg)
ED 05 3DB 06687 DAAA 27/178
3.5.8. INTEGRATED POLE MOUNTING INSTALLATION HARDWARE KIT CHECK
Check contents of all hardware bags according to the following Hardware installation Kits:
- 1+0 Integrated Antenna and ODU Mounting Hardware Installation Kit
- 1+1 Integrated Antenna and ODU Mounting Hardware Installation Kit
RF coupler - No Installation Hardware Kit is required for RF Coupler
1’
1A
13 – 38 GHz
7 – 8GHz
1B 1B
1AB228950005 1AB340390001
![Page 28: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/28.jpg)
ED 05 3DB 06687 DAAA 28/178
Integrated Pole Mounting
Table 1 - ODU Mounting Hardware Installation Kit Listing (3CC10752ABAA)
DESCRIPTION CODE PHOTO REF
INTEG. ANT. 1+0 quantity
INTEG. ANT. 1+1 quantity
ODU RF coupler (13-38 GHz) 1A 1
ODU RF coupler (7-8GHz) 1AB340390001 1B 1
ODU RF coupler (7-8GHz) 1AB228950005 1B 1
Pole Mounting for Integrated 3CC10752ABAA 2’ 1 1
Screw*CH-HD*HEX-SKT M6x20mm 1AD002150071 7 7 Washer*Waved 6.4mmx12mmx500/M6
1AD002290017 7 7
Screw*CH-HD*HEX-SKT 10x25mm 1AD002150100 7 7 NUT*HEX*HEX*-HD M6x5.2mm
1AD001970033 2 2
NUT*HEX*HEX*-HD M10x8.4mm
1AD001970046 4 4
Washer*Plain 6.4mmx14mm1.2mm/M6
1AD000870170 2 2
Washer*Waved 10.5mm21mm1mm/M10
1AD002290005 7 7
Washer*Waved 10.5mm22mm1mm/M10
1AD00870185 11 11
Screw*CH-HD*HEX-HEX-HD 1AD000500064 1 1 2G8 9438UXVIS (POUR RIDOIR) 3CC10816AAAA 3 3 2G0 9400UXVIS (POUR RIDOIR) 3CC11577AAAA 1 1 2G8 9438UXRIDOIR (POUR RIDOIR) 3CC1085AAAA 2 2 2G8 9438UXENTRETOISE 3CC10894AAA 4 4 NUT*HEX*HEX*-HD M10x6.8mm
1AD001970021 1 1
Washer*SC-SPG 10.5mm16.5mmx1.8mm/M10
1AD011670004 4 4
2G0 9400UXETRIER (CLAMP) 3CC06029AAAA 2 2 NUT*HEX*HEX*-HD M10x6.8mm
1AD001970046 4 4
ADHESIVE, DIMETHYLACRYLAT 1AC008760001
2’
Fine tuning
![Page 29: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/29.jpg)
ED 05 3DB 06687 DAAA 29/178
Table 2 - ODU Mounting Hardware Installation Kit Listing (3CC10752ABAB)
DESCRIPTION CODE PHOTO REF
INTEG. ANT. 1+0 quantity
INTEG. ANT. 1+1 quantity
ODU RF coupler (13-38 GHz) 1A 1
ODU RF coupler (7-8GHz) 1AB340390001 1B 1
ODU RF coupler (7-8GHz) 1AB228950005 1B 1
Pole Mounting for Integrated 3CC10752ABAA 2’ 1 1
Screw*CH-HD*HEX-SKT M6x20mm 1AD002150071 7 7 Washer*Waved 6.4mmx12mmx500/M6
1AD002290017 7 7
Screw*CH-HD*HEX-SKT 10x25mm 1AD002150100 7 7 NUT*HEX*HEX*-HD M6x5.2mm
1AD001970033 2 2
NUT*HEX*HEX*-HD M10x8.4mm
1AD001970046 4 4
Washer*Plain 6.4mmx14mm1.2mm/M6
1AD000870170 2 2
Washer*Waved 10.5mm21mm1mm/M10
1AD002290005 7 7
Washer*Waved 10.5mm22mm1mm/M10
1AD00870185 11 11
Screw*CH-HD*HEX-HEX-HD 1AD000500064 1 1 Washer*SC-SPG 10.5mm16.5mmx1.8mm/M10
1AD011670004 4 4
2G0 9400UXETRIER (CLAMP) 3CC06029AAAA 2 2 NUT*HEX*HEX*-HD M10x6.8mm
1AD001970046 4 4
See Table 1 - ODU Mounting Hardware Installation Kit Listing (3CC10752ABAA) on page 28 and Table 2- ODU Mounting Hardware Installation Kit Listing (3CC10752ABAB) on page 29 for a description of the
items shown in the photograph.. All parts shown should be received packed together in the same carton. The steerable support is wrapped and the remaining hardware is in two plastic bags, the large pieces in a
large plastic bag and the smaller hardware in a small plastic bag within the larger bag.
Without Fine tuning
![Page 30: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/30.jpg)
ED 05 3DB 06687 DAAA 30/178
3.5.8.1. Cable Grounding Kit
Cable Groundig Kit 3CC08166ABAA (16mm2 L=15m) to be cut on site and clamped on the terminal provided with the pole mounting
Table 3 – Cable Grounding Kit DESCRIPTION CODE Q.ty
Cable – Power 196*16MM2 1AC001060066 1 (L=15m) Washer*Plain 6.4mm x 14mm x 1.2mmm/M6 1AD000870170 3 Lug*Ring*Crimp*Uninsul 4.51mm 1AB032050033 6 Screw*CH-HD*HEX-SKT M6x20mm 1AD002150071 3 Nut*HEX*HEX-HD M6x5.2MM 1AD001970033 3
![Page 31: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/31.jpg)
ED 05 3DB 06687 DAAA 31/178
3.5.9. NON INTEGRATED ANTENNA POLE MOUNTING INSTALLATION HARDWARE KIT CHECK
Check contents of all hardware bags according to the following Hardware installation Kits:
- 1+0 NON Integrated Antenna and ODU Mounting Hardware Installation Kit
- 1+1 NON Integrated Antenna and ODU Mounting Hardware Installation Kit RF coupler No Installation Hardware Kit is required for RF Coupler
13 – 38GHz
7 – 8 GHz
1A
1
1AB228950005 1AB340390001
![Page 32: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/32.jpg)
ED 05 3DB 06687 DAAA 32/178
Pole mounting for NOT INTEGRATED antenna
3DB10137AAAA
NON Integrated pole mounting Installation Hardware Kit
Figure 11 – Not integrated antenna and ODU Mounting Hardware Installation Kit
Figure 12
Support Pole Mounting
Support tube Clamp
Washer Plain Washer*SC-SPG Nut*HEX*HEX-HD
Washer*SC-SPG Nut*HEX*-HEX-HD Screw*HEX-HD*HEX-HD
3
3
![Page 33: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/33.jpg)
ED 05 3DB 06687 DAAA 33/178
See Table 4 – on page 33 for a description of the items shown in the Figure 11 on page 32. All parts shown should be received packed together in the same carton. The steerable support is wrapped and the remaining hardware is in two plastic bags, the large pieces in a large plastic bag and the smaller hardware in a small plastic bag within the larger bag.
Table 4 – Non Integrated pole mounting installation kit
INSTALLATION KIT
DESCRIPTION CODE PHOTO REF
NON
INTEG. ANT. 1+0
quantity
NON
INTEG. ANT. 1+1
quantity
ODU RF coupler (13-38 GHz) 1 1
ODU RF coupler (7-8GHz) 1AB228950005 1A 1
ODU RF coupler (7-8GHz) 1AB340390001 1A 1 Pole mounting for NOT INTEGRATED antenna
3DB10137AAAA 3 1 1
Support Pole Mounting 3DB10138AAAA 1 1
Support tube 3CC13037AAAA 1 1
9400UXETRIER (CLAMP) 3CC06029ABAA 2 2
Washer*Plain 10.5mmx22mmx2mm/M10
1AD000870185 4 4
Washer*SC-SPG
10.5mmx16.5mmx1.8mm/M10
1AD011670004 8 8
Nut*Hex*Hex-HD
8.4mm/M10
1AD00190046 8 8
Screw*Hex-HD*Hex-HD
M10x40mm*SS
1AD002040083 4 4
Silicon Grease
Tube 5/8X2-3/16 (1.5cc)
1AC018650001 1 1
3.5.9.1. Cable Grounding Kit
Cable Groundig Kit 3CC08166ABAA (16mm2 L=15m) to be cut on site and clamped on the terminal provided with the pole mounting
Table 5 – Cable Grounding Kit DESCRIPTION CODE Q.ty
Cable – Power 196*16MM2 1AC001060066 1 (L=15m) Washer*Plain 6.4mm x 14mm x 1.2mmm/M6 1AD000870170 3 Lug*Ring*Crimp*Uninsul 4.51mm 1AB032050033 6 Screw*CH-HD*HEX-SKT M6x20mm 1AD002150071 3 Nut*HEX*HEX-HD M6x5.2MM 1AD001970033 3
![Page 34: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/34.jpg)
ED 05 3DB 06687 DAAA 34/178
POLE MOUNT PARTS CHECK
Check for correct steering support and pole mount assembly according to the following:
• Steering Support and Pole Mount Assembly for Radio with INTEGRATED ANTENNA WARNING: is mandatory to fix the four looking hooks like indicated and that is on the binary inside
Ref: 3CC10752ABAA – 3CC10752ABAB ODU and Integrated Antenna Cabinet grounding kit View
Figure 13 – Integrated POLE MOUNTING View
• ODU Support and Pole Mount Assembly for Radio with NON-INTEGRATED ANTENNA WARNING: is mandatory to fix the four looking hooks like indicated and that is on the binary inside
Ref: 1AB128510002 - ODU Support for NON Integrated Antenna POLE MOUNTING View
Figure 14 – RADIO and NON Integrated ANTENNA CABINET GROUNDING KIT View
ODU Fixing point onto the Pole
ODU Fixing point onto the Pole
![Page 35: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/35.jpg)
ED 05 3DB 06687 DAAA 35/178
3.6. Installation Tools required The 9400AWY system is supplied with three Tools Bag: - Station Tools Bag, (P/N 3DB 01399 AAAA MSZZQ). - Maintenance Tools Bag (P/N 3DB 01398 AAAA MSZZQ). - Installation Tools Bag (P/N 3DB 01397 AAAA MSZZQ). These documents are enclosures to the User Manual/Technical Handbook
3.7. Tables of installation IDU-ODU components The 9400 AWY composition catalogue includes also the installation components required for the most common installation cases. The following tables shows the installation part list related to the available system configuration and the antenna types.
3.7.1. Integrated or Not Integrated antenna installation components
The following installation components tables include all the items required for the integrated antenna or Not Integrated antenna cases, the tables show the item part numbers and the requested quantity related to the foreseen system. Note: 1In/N (2In/N) = it is possible to use INTEGRATED ANTENNA (In) or NON INTEGRATED ANTENNA (N) 1In (2In) = it is possible to use INTEGRATED ANTENNA (In) only 1N (2N) = it is possible to use NON INTEGRATED ANTENNA (N) only Legend: 1+1 HST 1+1 Hot Stand-by 1+1 HST SD 1+1 Hot Stand-by Space Diversity 1+1 FD AP 1+1 Frequency Diversity Alternate Polar 1+1 FD DA 1+1 Frequency Diversity Dual Antenna
![Page 36: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/36.jpg)
ED 05 3DB 06687 DAAA 36/178
9470 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description
Alactel Part
Number Transceiver
1+0 1+1HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3DB06691ABAA TRX 9470 7.1-7.75 GHZ LHB 1 2 2 2 2 (A)
3DB06692ABAA TRX 9470 7.25-7. 9 GHZ LHB 1 2 2 2 2 (A)
3DB06693ABAA TRX 9470 7.7-8.4 GHZ LHB 1 2 2 2 2 (A)
3DB06694ABAA TRX 9470 8.0-8.5 GHZ UHB 1 2 2 2 2 (A)
Alcatel part
number Branching & Filters 1+0 1+1
HST1+1
HST SD 1+1
FD AP 1+1
FD DA Note
3DB06774AAXX BRANCHING 7GHZ CH1-1P P.SH. 154_A MHz 1 2 2 2 2
3DB06774ABXX BRANCHING 7GHZ CH2-2P P.SH. 154_A MHz 1 2 2 2 2
3DB06775AAXX BRANCHING 7GHZ CH1-1P P.SH.154_B/160 MHz 1 2 2 2 2
3DB06775ABXX BRANCHING 7GHZ CH2-2P P.SH.154_B/160 MHz 1 2 2 2 2
3DB06776AAXX BRANCHING 7GHZ CH1-1P P.SH.168 MHZ 1 2 2 2 2
3DB06776ABXX BRANCHING 7GHZ CH2-2P P.SH.168 MHZ 1 2 2 2 2
3DB06777AAXX BRANCHING 7GHZ CH1-1P P.SH.182 MHZ 1 2 2 2 2
3DB06777ABXX BRANCHING 7GHZ CH2-2P P.SH.182 MHZ 1 2 2 2 2
3DB06778AAXX BRANCHING 7GHZ CH1-1P P.SH.196 MHZ 1 2 2 2 2
3DB06778ABXX BRANCHING 7GHZ CH2-2P P.SH.196 MHZ 1 2 2 2 2
3DB06779AAXX BRANCHING 7GHZ CH1-1P P.SH.245 MHZ 1 2 2 2 2
3DB06779ABXX BRANCHING 7GHZ CH2-2P P.SH.245 MHZ 1 2 2 2 2
3DB06780AAXX BRANCHING 7GHZ CH1-1P P.SH.161_A MHz 1 2 2 2 2
3DB06780ABXX BRANCHING 7GHZ CH2-2P P.SH.161_A MHz 1 2 2 2 2
3DB06781AAXX BRANCHING 7GHZ CH1-1P P.SH.161_C MHz 1 2 2 2 2
3DB06781ABXX BRANCHING 7GHZ CH2-2P P.SH.161_B MHz 1 2 2 2 2
3DB06782AAXX BRANCHING 7GHZ CH1-1P P.SH.161_C MHz 1 2 2 2 2
3DB06782ABXX BRANCHING 7GHZ CH2-2P P.SH.161_C MHz 1 2 2 2 2
3DB06783AAXX BRANCHING 7GHZ CH1-1P P.SH.161_D MHz 1 2 2 2 2
3DB06783ABXX BRANCHING 7GHZ CH2-2P P.SH.161_D MHz 1 2 2 2 2
3DB06784AAXX BRANCHING 7GHZ CH1-1P P.SH.161_E MHz 1 2 2 2 2
3DB06784ABXX BRANCHING 7GHZ CH2-2P P.SH.161_E MHz 1 2 2 2 2
3DB06785AAXX BRANCHING 7GHZ CH1-1P P.SH.161_F MHz 1 2 2 2 2
3DB06785ABXX BRANCHING 7GHZ CH2-2P P.SH.161_F MHz 1 2 2 2 2
3DB06786AAXX BRANCHING 8GHZ CH1-1P P.SH.294/305/311 MHz 1 2 2 2 2
3DB06786ABXX BRANCHING 8GHZ CH2-2P P.SH.294/305/311 MHz 1 2 2 2 2
3DB06787AAXX BRANCHING 8GHZ CH1-1P P.SH.151 MHz 1 2 2 2 2
3DB06787ABXX BRANCHING 8GHZ CH2-2P P.SH.151 MHz 1 2 2 2 2
3DB06788AAXX BRANCHING 8GHZ CH1-1P P.SH.266 MHZ 1 2 2 2 2
3DB06788ABXX BRANCHING 8GHZ CH2-2P P.SH.266 MHZ 1 2 2 2 2
3DB06789AAXX BRANCHING 8GHZ CH1-1P P.SH.119/126 MHz 1 2 2 2 2
3DB06789ABXX BRANCHING 8GHZ CH2-2P P.SH.119/126 MHz 1 2 2 2 2
3DB10060AAXX BRANCHING 7GHZ CH1-1P P.SH.154_C MHZ 1 2 2 2 2
3DB10059AAXX BRANCHING 7GHZ CH2-2P P.SH.168_B MHZ 1 2 2 2 2
3DB10073AAXX BRANCHING 8GHZ CH1-1P P.SH208 MHZ 1 2 2 2 2
3DB10073ABXX BRANCHING 8GHZ CH2-1P P.SH208 MHZ 1 2 2 2 2
Note: A - ODU 32E1
![Page 37: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/37.jpg)
ED 05 3DB 06687 DAAA 37/178
9470 AWY - ODU INSTALLATION COMPONENTS
Alcatel part
number Installation Materials 1+0 1+1
HST1+1
HST SD 1+1
FD AP 1+1
FD DA Note
1AB228950005 7.1-8.5 GHz 10dB Integrated Coupler 1 3DB00677AAXX 7GHz 2FT SP integrated antenna 1In 2In 2In 1AB340390001 7.1-8.5 GHz 10dB Integrated Coupler 1 3DB00675AAXX 8GHz 2FT SP integrated antenna 1In 2In 2In 1AF11293AAAA 7.1-8.5 GHz 3FT Integrated antenna with PM 1In 1In 1AF11284AAAA 7.1-8.5 GHz 4FT Integrated antenna with PM 1In 1In 1AF11977AAAA Flex Twist WR112 PDR84/UBR84 L=1m 1N 2N 1AB128510002 Non Integrated Antenna Pole Mounting 3DB01459AAAA Nose adapter WR112 kit for not int antenna 3CC10752ABAA Integrated Pole Mounting for 1-2FT antenna 1In 2In 2In 3CC10752ABAB Integrated Pole Mounting for 1-2FT antenna 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N. 90° 50 ohm
3CC08166ABAA Cabinet grounding kit Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna
Note: next introduction in substitution of actual configuration Actual Configuration
Next introduction Description
1AB128510002 3DB10137AAXX POLE MOUNTING NON INTEGRATED ANTENNA 3DB01459AAAA 3DB10135AAAA WR112 ADAPTER KIT 1AF11977AAXX 3CC08010ABAB Flex Twist WR112 PBR84/UBR84 L=1m
Table 6 – 9470 AWY - ODU Installation materials for Integrated or Non Integrated antenna cases
![Page 38: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/38.jpg)
ED 05 3DB 06687 DAAA 38/178
9413 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description
Alactel Part
Number
Coupler 1+0 1+1
HST 1+1
HST SD1+1
FD AP 1+1
FD DA Note
3CC13472ABXX 13/15 GHz 10db Coupler 1 Alcatel
part number
Transceiver 1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13688ABAA ODU 9413 fs=266MHZ 1-1’ 1 2 2 2 2 (A)
3CC13689ABAA ODU 9413 fs=266MHZ 2-2’ 1 2 2 2 2 (A)
3CC13690ABAA ODU 9413 fs=266MHZ 1’-2 1 2 2 2 2 (A)
3CC13691ABAA ODU 9413 fs=266MHZ 2’-2 1 2 2 2 2 (A)
Alcatel part
number Installation Materials 1+0 1+1
HST 1+1
HST SD1+1
FD AP 1+1
FD DA Note
1AF01893AAXX 13 GHz 1FT SP INTEGR.ANTENNA ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF10018AAXX 13 GHz 2FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF01894AAXX 13 GHz 2FT SP INTEGR.ANTENNA ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF11285AAXX 13 GHz 3FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 1AF11482AAXX 13 GHz 4FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 3CC05751ACAA 13 GHz Flex Twist 600mm 1N 1In/N 2N 2 2N 1AB146090003 Nose-Adapter (Non Integr.Antenna) 1N 1In/N 2N 2N 2N
1AB128510002 Non Integrated Antenna Pole Mounting 1N 1N 2N 2N 2N 3CC10752ABAA Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC10752ABAB Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N.90° ohm 90°
3CC08166ABAA Cabinet grounding kit Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna Note: A - ODU 32E1
Table 7 – 9413 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases
![Page 39: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/39.jpg)
ED 05 3DB 06687 DAAA 39/178
9415 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description Alactel Part
Number Coupler
1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13472ABXX 13/15 GHz 10db Coupler 1
Alcatel part
number Transceiver 1+0 1+1
HST 1+1
HST SD 1+1
FD AP 1+1
FD DA Note
3CC13704AAXX ODU 9415 fs=490MHz 1-1’ 1 2 2 2 2 3CC13705AAXX ODU 9415 fs=490MHz 2-2’ 1 2 2 2 2 3CC13706AAXX ODU 9415 fs=490MHz 1’-1 1 2 2 2 2 3CC13707AAXX ODU 9415 fs=490MHz 2’-2 1 2 2 2 2 3CC13696ABAA ODU 9415 fs=420MHz 1-1’ 1 2 2 2 2 (A) 3CC13697ABAA ODU 9415 fs=420MHz 1-1’ 1 2 2 2 2 (A) 3CC13698ABAA ODU 9415 fs=420MHz 2-2’ 1 2 2 2 2 (A) 3CC13699ABAA ODU 9415 fs=420MHz 2’-2 1 2 2 2 2 (A) 3CC13700AAXX ODU 9415 fs=475MHz 1-1’ HP 1 2 2 2 2 3CC13701AAXX ODU 9415 fs=475MHz 1-1’ HP 1 2 2 2 2 3CC13702AAXX ODU 9415 fs=475MHz 2-2’ HP 1 2 2 2 2 3CC13703AAXX ODU 9415 fs=475MHz 2’-2 HP 1 2 2 2 2 3CC13704ABAA ODU 9415 fs=490MHz 1 1 2 2 2 2 (A) 3CC13705ABAA ODU 9415 fs=490MHz 2 1 2 2 2 2 (A) 3CC13706ABAA ODU 9415 fs=490MHz 1P 1 2 2 2 2 (A) 3CC13707ABAA ODU 9415 fs=490MHz 2P 1 2 2 2 2 (A) 3CC14077AAXX ODU 9415 fs=475MHz 1-1’ 1 2 2 2 2 3CC14078AAXX ODU 9415 fs=475MHz 1-1’ 1 2 2 2 2 3CC14079AAXX ODU 9415 fs=475MHz 2-2’ 1 2 2 2 2 3CC14080AAXX ODU 9415 fs=475MHz 2’-2 1 2 2 2 2 3CC13708AAXX ODU 9415 fs=640MHz 1-1’ 1 2 2 2 2 3CC13710AAXX ODU 9415 fs=640MHz 1’-1 1 2 2 2 2 3CC13692ABAA ODU 9415 fs=315MHz 1-1’ 1 2 2 2 2 (A) 3CC13693ABAA ODU 9415 fs=315MHz 1-1’ 1 2 2 2 2 (A) 3CC13694ABAA ODU 9415 fs=315MHz 2-2’ 1 2 2 2 2 (A) 3CC13695ABAA ODU 9415 fs=315MHz 2’-2 1 2 2 2 2 (A) 3CC13709ABAA ODU 9415 fs=644MHz 1-1’ 1 2 2 2 2 (A) 3CC13711ABAA ODU 9415 fs=644MHz 1’-1 1 2 2 2 2 (A) 3CC13712ABAA ODU 9415 fs=728MHz 1 1 2 2 2 2 (A) 3CC13713ABAA ODU 9415 fs=728MHz 1P 1 2 2 2 2 (A)
Alcatel part
number Installation Materials 1+0 1+1
HST 1+1
HST SD 1+1
FD AP 1+1
FD DA Note
1AF13287AAAA 15 GHz 1FT SP AWY FULL INTEGRATED ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF10018ABAA 15 GHz 2FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF01892AAAA 15 GHz 2FT SP INTEGR.ANTENNA ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF11285AAXX 15 GHz 3FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 1AF11482AAXX 15 GHz 4FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 3CC05750ACAA Flex Twist 15 GHz 600mm 1N 1In/N 2N 2 2N 1AB146090001 Nose-Adapter (Non Integrated Antenna) 1N 1In/N 2N 2N 2N 1AB128510002 Non Integrated Antenna Pole Mounting 1N 1N 2N 2N 2N
3CC10752ABAA Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC10752ABAB Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N.90° 50 ohm 3CC08166ABAA Cabinet grounding kit
Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna Note: A - ODU 32E1
Table 8 – 9415 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases
![Page 40: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/40.jpg)
ED 05 3DB 06687 DAAA 40/178
9418 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description Alactel Part
Number Coupler
1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13473ABXX 18/23/245 GHz 10db Coupler 1 Alcatel
part number
Transceiver 1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC12991AAXX ODU 9418 fs=1010MHz 1-1’ 1 2 2 2 2 3CC12992AAXX ODU 9418 fs=1010MHz 2-2’ 1 2 2 2 2 3CC12993AAXX ODU 9418 fs=1010MHz 1’-1 1 2 2 2 2 3CC12994AAXX ODU 9418 fs=1010MHz 2’-2 1 2 2 2 2 3CC12999AAXX ODU 9418 fs=340MHz 1-1’ ANSI 1 2 2 2 2 3CC13000AAXX ODU 9418 fs=340MHz 1-1’ ANSI 1 2 2 2 2 3CC13001AAXX ODU 9418 fs=340MHz 2-2’ ANSI 1 2 2 2 2 3CC13002AAXX ODU 9418 fs=340MHz 2’-2 ANSI 1 2 2 2 2 3CC13947AAXX ODU 9418 fs=1560MHz 1-1’ ANSI 1 2 2 2 2 3CC13948AAXX ODU 9418 fs=1560MHz 1-1’ ANSI 1 2 2 2 2 3CC13468AAXX ODU 9418 fs=1008MHz 1-1’ 1 2 2 2 2 3CC13469AAXX ODU 9418 fs=1008MHz 2-2’ 1 2 2 2 2 3CC13470AAXX ODU 9418 fs=1008MHz 1’-1 1 2 2 2 2 3CC13471AAXX ODU 9418 fs=1008MHz 1’-1 1 2 2 2 2 3CC12995ABAA ODU 9418 fs=1560MHz 1-1’ ETSI 1 2 2 2 2 (A) 3CC12996ABAA ODU 9418 fs=1560MHz 1’-1 ETSI 1 2 2 2 2 (A) 3CC13714ABAA ODU 9418 fs=340MHz 1-1’ ETSI 1 2 2 2 2 (A) 3CC13715ABAA ODU 9418 fs=340MHz 2’-2 ETSI 1 2 2 2 2 (A) 3CC13716ABAA ODU 9418 fs=340MHz 1-1’ ETSI 1 2 2 2 2 (A) 3CC13717ABAA ODU 9418 fs=340MHz 2-2’ ETSI 1 2 2 2 2 (A) 3CC14472AAXX ODU 9418 fs=1092.5MHz 1-1’ 1 2 2 2 2 3CC14473AAXX ODU 9418 fs=1092.5MHz 2-2’ 1 2 2 2 2 3CC14474AAXX ODU 9418 fs=1092.5MHz 1’-1 1 2 2 2 2 3CC14475AAXX ODU 9418 fs=1092.5MHz 2’-2’ 1 2 2 2 2 3CC14780ABAA ODU 9418 fs=1008-1010MHz 1 1 2 2 2 2 (A) 3CC14781ABAA ODU 9418 fs=1008-1010MHz 2 1 2 2 2 2 (A) 3CC14782ABAA ODU 9418 fs=1008-1010MHz 1P 1 2 2 2 2 (A) 3CC14783ABAA ODU 9418 fs=1008-1010MHz 2P 1 2 2 2 2 (A)
Alcatel part
number Installation Materials 1+0 1+1
HST 1+1
HST SD1+1
FD AP 1+1
FD DA Note
1AF10018LAAAA 18 GHz 1FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF13286AAAA 18 GHz 1FT SP AWY FULL INTEGRATED ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF10018ACAA 18 GHz 2FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF13293AAAA 18 GHz 2FT SP AWY FULL INTEGRATED ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF11290AAXX 18 GHz 3FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 1AF11291AAXX 18 GHz 4FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 3CC05749ACAA 18/23/25 GHz Flex Twist 1N 1In/N 2N 2 2N 1AB146090002 18/23/25 Nose-Adapter (Non Integr.Antenna) 1N 1In/N 2N 2N 2N 1AB128510002 Non Integrated Antenna Pole Mounting 1N 1N 2N 2N 2N
3CC10752ABAA Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC10752ABAB Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N.90° 50 ohm
3CC08166ABAA Cabinet grounding kit Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna Note: A - ODU 32E1
Table 9 – 9418 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases
![Page 41: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/41.jpg)
ED 05 3DB 06687 DAAA 41/178
9423 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description Alactel Part
Number Coupler
1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13473ABXX 18/23/245 GHz 10db Coupler 1 Alcatel
part number
Transceiver 1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13718ABAA ODU 9423 fs=1008MHz 1-1’ 1 2 2 2 2 (A) 3CC13719ABAA ODU 9423 fs=1008MHz 2-2’ 1 2 2 2 2 (A) 3CC13720ABAA ODU 9423 fs=1008MHz 1’-1 1 2 2 2 2 (A) 3CC13721ABAA ODU 9423 fs=1008MHz 2’-2 1 2 2 2 2 (A) 3CC13722AAXX ODU 9423 fs=1200MHz 1-1’ ANSI 1 2 2 2 2 3CC13723AAXX ODU 9423 fs=1200MHz 1-1’ ANSI 1 2 2 2 2 3CC13724AAXX ODU 9423 fs=1200MHz 2-2’ ANSI 1 2 2 2 2 3CC13725AAXX ODU 9423 fs=1200MHz 2’-2 ANSI 1 2 2 2 2 3CC14388AAXX ODU 9423 fs=1200MHz 1-1’ ETSI 1 2 2 2 2 3CC14389AAXX ODU 9423 fs=1200MHz 1-1’ ETSI 1 2 2 2 2 3CC14390AAXX ODU 9423 fs=1200MHz 1-1’ ETSI 1 2 2 2 2 3CC14391AAXX ODU 9423 fs=1200MHz 2-2’ ETSI 1 2 2 2 2 3CC14400AAXX ODU 9423 fs=1197MHz 1-1’ 1 2 2 2 2 3CC14401AAXX ODU 9423 fs=1197MHz 1’-1 1 2 2 2 2 3CC14402AAXX ODU 9423 fs=1197MHz 2-2’ 1 2 2 2 2 3CC14403AAXX ODU 9423 fs=1197MHz 2’-2 1 2 2 2 2 3CC13726AAXX ODU 9423 fs=1232MHz 1-1’ 1 2 2 2 2 3CC13727AAXX ODU 9423 fs=1232MHz 2’-2 1 2 2 2 2 3CC13728AAXX ODU 9423 fs=1232MHz 1-1’ 1 2 2 2 2 3CC13729AAXX ODU 9423 fs=1232MHz 2-2’ 1 2 2 2 2 3CC14776ABAA ODU 9423 fs=1200-1232MHz 1 1 2 2 2 2 (A) 3CC14777ABAA ODU 9423 fs=1050-1200-1232MHz 2 1 2 2 2 2 (A) 3CC14778ABAA ODU 9423 fs=1200-1232MHz 1P 1 2 2 2 2 (A) 3CC14779ABAA ODU 9423 fs=1050-1200-1232MHz 2P 1 2 2 2 2 (A)
Alcatel part
number Installation Materials 1+0 1+1
HST 1+1
HST SD 1+1
FD AP 1+1
FD DA Note
1AF10018ADAA 23 GHz 1FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF13285AAAA 23 GHz 1FT SP AWY FULL INTEGRATED ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF10018AEAA 23 GHz 2FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF13292AAAA 23 GHz 2FT SP AWY FULL INTEGRATED ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF11292AAXX 23 GHz 3FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 1AF11288AXX 23 GHz 4FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 3CC05749ACAA 18/23/25 GHz Flex Twist 1N 1In/N 2N 2 2N 1AB146090002 18/23/25 Nose-Adapter (Non Integr.Antenna) 1N 1In/N 2N 2N 2N 1AB128510002 Non Integrated Antenna Pole Mounting 1N 1N 2N 2N 2N
3CC10752ABAA Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC10752ABAB Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N.90° 50 ohm
3CC08166ABAA Cabinet grounding kit Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna Note: A - ODU 32E1
Table 10 – 9423 AWY - ODU Installation materials for Integrated or Not Integrated antenna case
![Page 42: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/42.jpg)
ED 05 3DB 06687 DAAA 42/178
9425 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description Alactel Part
Number Coupler
1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13473ABXX 18/23/245 GHz 10db Coupler 1 Alcatel
part number
Transceiver 1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13734ABAA ODU 9425 fs=1008MHz 1-1’ 1 2 2 2 2 (A) 3CC13735ABAA ODU 9425 fs=1008MHz 2-2’ 1 2 2 2 2 (A) 3CC13736ABAA ODU 9425 fs=1008MHz 1’-1 1 2 2 2 2 (A) 3CC13737ABAA ODU 9425 fs=1008MHz 2’-2 1 2 2 2 2 (A)
Alcatel part
number Installation Materials 1+0 1+1
HST 1+1
HST SD1+1
FD AP 1+1
FD DA Note
1AF10018AFAA 25 GHz 1FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF13284AAAA 25 GHz 1FT SP AWY FULL INTEGRATED ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF13284AAAA 25 GHz 1FT AWY FULL INTEGRATED ANDREW 1AF10018AHAA 25 GHz 2FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF13291AAAA 25 GHz 2FT SP AWY FULL INTEGRATED ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF11518AAXX 25 GHz 3FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 1AF11287AAXX 25 GHz 4FT SP INTEGR.ANTENNA 1In/N 1In/N 2In/N 1N 2In/N 3CC05749ACAA 18/23/25 GHz Flex Twist 1N 1In/N 2N 2 2N 1AB146090002 18/23/25 Nose-Adapter (Non Integr.Antenna) 1N 1In/N 2N 2N 2N 1AB128510002 Non Integrated Antenna Pole Mounting 1N 1N 2N 2N 2N
3CC10752ABAA Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC10752ABAB Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N.90° 50 ohm
3CC08166ABAA Cabinet grounding kit Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna Note: A - ODU 32E1
Table 11 – 9425 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases
![Page 43: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/43.jpg)
ED 05 3DB 06687 DAAA 43/178
9428 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description Alactel Part
Number Coupler
1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13474ABXX 28/38 GHz 10db Coupler 1 Alcatel
part number
Transceiver 1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13738ABAA ODU 9428 fs=1008MHz 1-1’ 1 2 2 2 2 (A) 3CC13739ABAA ODU 9428 fs=1008MHz 2-2’ 1 2 2 2 2 (A) 3CC13740ABAA ODU 9428 fs=1008MHz 1’-1 1 2 2 2 2 (A) 3CC13741ABAA ODU 9428 fs=1008MHz 2’-2 1 2 2 2 2 (A)
Alcatel part
number Installation Materials 1+0 1+1
HST 1+1
HST SD 1+1
FD AP 1+1
FD DA Note
3DB00658AAXX 28 GHz 1FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 3DB00658AAXX 28 GHz 1FT SP INTEGR.ANTENNA ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF13283AAAA 28 GHz 1FT AWY FULL INTEGRATED ANDREW 3DB00659AAXX 28 GHz 2FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 3DB00659AAXX 28 GHz 2FT SP INTEGR.ANTENNA ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF13290AAAA 28 GHz 2FT AWY FULL INTEGRATED ANDREW 3DB00682AAXX 28/38 GHz Flex Twist 1N 1In/N 2N 2 2N 3DB02082AAXX 28/38 Nose-Adapter (Non Integr.Antenna) 1N 1In/N 2N 2N 2N 3DB00692AAXX FLEX-TWIST ARM SUPPORT 28-38GHz
(Non Integr.Antenna) 1 1 2 2 2
3DB03455AAXX Universal Round Collar 1 1 2 2 2 1AB128510002 Non Integrated Antenna Pole Mounting 1N 1N 2N 2N 2N
3CC10752ABAA Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC10752ABAB Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N.90° 50 ohm
3CC08166ABAA Cabinet grounding kit Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna Note: A - ODU 32E1
Table 12 – 9428 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases
![Page 44: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/44.jpg)
ED 05 3DB 06687 DAAA 44/178
9438 AWY - ODU INSTALLATION COMPONENTS
Quantity / Configuration Description Alactel Part
Number Coupler
1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC13474AB** 28/38 GHz 10db Coupler 1 Alcatel
part number
Transceiver 1+0 1+1 HST
1+1 HST SD
1+1 FD AP
1+1 FD DA Note
3CC12987ABAA ODU 9438 fs=1260MHz 1-1’ 1 2 2 2 2 (A) 3CC12988ABAA ODU 9438 fs=1260MHz 2-2’ 1 2 2 2 2 (A) 3CC12989ABAA ODU 9438 fs=1260MHz 1’-1 1 2 2 2 2 (A) 3CC12990ABAA ODU 9438 fs=1260MHz 2’-2 1 2 2 2 2 (A) 3CC13933AAXX ODU 9438 fs=700MHz Canada 2-2’ 1 2 2 2 2 3CC13934AAXX ODU 9438 fs=700MHz Canada 2’-2 1 2 2 2 2 3CC13052AAXX ODU 9438 fs=700MHz 1’-1 ANSI 1 2 2 2 2 3CC13053AAXX ODU 9438 fs=700MHz 2-2’ ANSI 1 2 2 2 2 3CC13054AAXX ODU 9438 fs=700MHz 1’-1 ANSI 1 2 2 2 2 3CC13055AAXX ODU 9438 fs=700MHz 2’-2 ANSI 1 2 2 2 2 1 2 2 2 2
Alcatel part
number Installation Materials 1+0 1+1
HST 1+1
HST SD1+1
FD AP 1+1
FD DA Note
1AF10018AJAA 38 GHz 1FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF01739AAAA 38 GHz 1FT SP INTEGR.ANTENNA ANDREW 1In/N 1In/N 2In/N 1N 2In/N 3DB00656AAXX 38 GHz 1FT AWY FULL INTEGRATED ANDREW 1AF10018AGAA 38 GHz 2FT SP INTEGR.ANTENNA RFS 1In/N 1In/N 2In/N 1N 2In/N 1AF01740AAAA 38 GHz 2FT SP INTEGR.ANTENNA ANDREW 1In/N 1In/N 2In/N 1N 2In/N 1AF13289AAAA 38 GHz 2FT AWY FULL INTEGRATED ANDREW 3DB00682AAXX 28/38 GHz Flex.Twist 1N 1In/N 2N 2 2N 3DB02082AAXX 28/38 Nose-Adapter (Non Integr.Antenna) 1N 1In/N 2N 2N 2N 3DB00692AAXX FLEX-TWIST ARM SUPPORT 28-38GHz
(Non Integr.Antenna) 1 1 2 2 2
3DB03455AAXX Universal Round Collar 1 1 2 2 2 1AB128510002 Non Integrated Antenna Pole Mounting 1N 1N 2N 2N 2N
3CC10752ABAA Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC10752ABAB Integrated Antenna Pole Mounting 1In 1In 2In 2In 3CC06503AAXX Consumable set 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 Filotex Coax cable 50 ohm 1AB095530021 Filotex conn. male N.90° ohm 90°
3CC08166ABAA Cabinet grounding kit Q.ty In = Integrated Antenna Q.ty N= Not Integrated Antenna Note: A - ODU 32E1
Table 13 – 9438 AWY - ODU Installation materials for Integrated or Not Integrated antenna cases
![Page 45: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/45.jpg)
ED 05 3DB 06687 DAAA 45/178
3.7.2. IDU installation components
Two IDU boxes (Main / Extension) are foreseen:
- (1+0): 44,45 x 443 x 210mm (=> 1U) + Mini-distributor (=> 0.6U)
- (1 Main + Extension): 89,9x443x 210mm (=> 2U) + Mini-distributor (=> 0.6U)
Indoor units (IDU) of the 9400 AWY system can be installed in different ways as described below:
- Installation on a special workbench or desk;
- Installation on a suitable wooden or masonry wall;
- Installation in a 19" Din rack
- Installation in a 21" ETSI rack
For each of the above type of installation special mechanical supporting fixtures are available.
Table 14 -.on page 45 gives a list of the installation materials that are included in the catalogue.
Table 14 - IDU Installation components
IDU INSTALLATION COMPONENTS ALCATEL
PART NUMBER NAME NOTE
3DB04656AAAA ETSI RACK H 2200 3DB04657AAAA ETSI RACK H 2000 3CC09614AAAA IDU Wall Mounting 3DB06612AAAA 1+0 ETSI RackMounting Kit 3CC13423AAAA Grounding Kit wall mounting 3CC07946AAAA Telephone Handset 1AF12831AAAA Telephone Handset 3DB06594AAAA User Service Channel cable for 1+1 3DB06593AAAA E3/DS3 cable for 1+1 3CC13659AAAA 37 wires 8E1/DS1 cable for 1+1 3DB06592ABAA 100 wire SCSI cable for 1+1 1AB152220001 6 Breakers DC Power Panel 1AD053060001 6 Fuse DC Power Panel B0177096497 Single fuse holder with fuse 1AB058580014 One ciruit breaker 1AB128500002 IDU-ODU cable grounding kit 1AC001100022 FILOTEX COAX CABLE 50 OHM 1AB095530021 FILOTEX CONN.MALE 90° 50 OHM 3DB05594AAAA HA-HC/SC cable 3DB05922AAAA NMS/AUDIO CABLE L=1.6 m 3DB05923AAAA NMS/AUDIO CABLE L=6.4 m 3DB10064AAAA NMS Interface AWY-MELODIE IDU L=6.4m 3DB10063AAAA NMS Interface AWY-MELODIE IDU L=1.6m 1AB054120027 RS232 CT cable 3DB10003AAAA 75 ohm coax cable 8XE1/DS1 IDU/Distr no connectors L:15 1AB061220005 Male coax connector 1.0/2.3 1AB009870002 Male coax connector 1.6/5.6 1AB006420060 Male coax connector BNC 75ohm 1AB009790019 Panel coax connector 1.0/2.3 1AB002130006 Panel coax connector 1.6/5.6 1AB006020076 Panel coax connector BNC 75ohm 1AC011980001 120ohm 8X2 twisted pair cable 3CC07899AAAC 8E1/DS1 SUB D37 connector 1AC021980001 100ohm cable for 8XDS1 3DB05850AAXX ADAPT.CABLE 1.0/2.3 MALE-BNC.FEMALE 3DB05851AAXX ADAPT.CABLE 1.0/2.3 MALE 1.6/5.6 FEMALE 3CC08951ACAA 120ohm cable L904/16p lg 15m w connector 3CC07917AAAA COMPAX module 10 pairs and covers 3DB10008AAAA COAX CABLE 8XE1/DS1 IDU/DISTR. 1.0/2.3 – 75ohm UNB 3DB10007AAXX COAX CABLE 8XE1/DS1 IDU/DISTR. 120 ohm BAL 3CC08061AAAA DISTRIBUTOR SUBRACK FOR 1.6/5.6
![Page 46: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/46.jpg)
ED 05 3DB 06687 DAAA 46/178
3CC07885ABAA COAX CABLE 8XE1/DS1 IDU/DISTR. 1.6/5.6 – 75ohm UNB 2m 3CC08062AAAA 1U DISTRIBUTOR SUBRACK FOR 120 ohm non EMC 3CC07810AAAA 3U DISTRIBUTOR SUBRACK FOR 120 ohm EMC 3CC07658AAAB Cable 8XE1/DS1 IDU/DISTR. 120 ohm 2m 3CC08061ABAA DISTRIBUTOR SUBRACK FO BNC 3CC07759ABAA Cable 8XE1/DS1 IDU/DISTR. BNC 75 ohm UNB 2m 3CC08209AAAA Power supply connection 24V (3X2.52) 3CC08212AAAA Connection cable 24V (3X102) 3CC08165AAAA Power supply connection 48V (3X1.52) 3CC08211AAAA Connection cable 48V (3X42) 3CC06503AAXX Consumable set 3CC13477AAXX Light service kit cable 3DB05021AAAA Ethernet crossover cable – L=2m 3DB14051AAAA Ethernet crossover cable – L=6.4m 3DB14046AAAA Ethernet – L=2m 3DB14050AAAA Ethernet – L=6,4m 3DB10087AAAA ESC AWY connection – L= 1.6m 3DB10088AAAA ESC AWY connection – L= 6.4m
Note: Kit Also Used For Bench Installation The same mechanical support intended for wall installations can be used for bench installation to provide greater stability on the equipped bench or desk.
The workbench or desk to be used is a table especially fitted with safety power outlets, located in a suitable spot of the room, and suitably protected against accidental tampering.
![Page 47: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/47.jpg)
ED 05 3DB 06687 DAAA 47/178
4. OUTDOOR UNITS INSTALLATION (ODU)
4.1. General 9400 AWY ODU units are designed for assembly:
-Either with an integrated antenna connected directly to the Outdoor equipment, see paragraph 4.4 and 4.5.
-With one or more non–integrated antennas, see paragraph 4.8.
Locking Hook
Light Service Kit
I/O Cable IDU-ODU
Grounding point
Light Service Kit I/O Cable
IDU-ODU
Figure 15 - 13-38GHz ODU rear and front views
![Page 48: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/48.jpg)
ED 05 3DB 06687 DAAA 48/178
LOCKING HOOK
GROUNDING POINT
I/O CABLE IDU/ODUPORTABLE SERVICE KIT
PORTABLE SERVICE KIT
I/O CABLE IDU/ODU
Figure 16 – 7-8 GHz ODU rear and front views
LIGHT SERVICE KIT
LIGHT SERVICE KIT
![Page 49: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/49.jpg)
ED 05 3DB 06687 DAAA 49/178
4.2. TRANSCEIVER (A-box) and BRANCHING (D-box) boxes coupling
A-BOX
D-BOXLOW
FREQ.
HIGH FREQ.
HIGH FREQ.
LOW FREQ.
Detail “A”
Detail “B”
Figure 17 – D-BOX and A-BOX Integration
For more information to see the User Manual/Technical Handbook 9400AWY Rel.2.0
![Page 50: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/50.jpg)
ED 05 3DB 06687 DAAA 50/178
4.3. Typical installation layout Figure 18 on page 51, Figure 19 page 52, and Figure 20 on page 53 show typical installation layouts. The installation materials included from Table 6 to Table 13 are also pointed out and shown in the figures NB: Not in all 1+1 configurationthe external coupler is used. In 1+1HSB-SD the coupler is not used, in this case it is necessary to use the same Flextwist used in 1+0, that is the 1AF119977AAAA
Figure 18 on page 51 and Figure 19 on page 52 show typical installations of 1+0 and 1+1 systems respectively, both with 30 cm or 60 cm. integrated antenna
Figure 20 on page 53 shows a typical installation of 1+0 system with not integrated antenna for 13-38 GHz frequency range. The antenna is installed near the ODU installation making use of the 600 mm. flexible twist wave-guide, included in Error! Reference source not found. on page Error! Bookmark not defined. (PN 597210011).
Figure 59 on page 86shows the typical installations of ODU 1+1 on the pole mounting with “Not Integrated” antenna for 7-8GHz frequency range. The antenna is installed making use of the 1m flexible twist wave-guide (1AF02749ABAAA), included in Table 6 on page 37.
![Page 51: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/51.jpg)
ED 05 3DB 06687 DAAA 51/178
INDOORUNIT
GROUNDING
TYPE N CONNECTOR
See NOTE B and C
Rear side
GROUNDINGPOINT
POLE
Colson Cable ties
GROUNDING
See NOTE A/3
See NOTE A/3
Rack (Shelf or Desktop) See NOTE A/4
Figure 18 - Typical installation of 1+0 ODU with integrated antenna, 30 cm or 60 cm.
NOTE A:
1) The cable is fixed along the supporting pipe or pole by the normal methods (Colson cable ties are supplied in the optional consumables kit)
2) see NOTE B. 3) The rack can be connected to ground using the top or the bottom side grounding points. 4) For the installation on shelf or desktop the indoor unit must be connected to ground using the
rear side grounding point.
NOTE B : Coaxial cable grounding Kit
First in prossimity of ODU Second in prossimity of building access In case of cable length over 80 m, the cable grounding kit must be implemented every 40 meter cable distance.
NOTE C: see par. 4.14 IDU / ODU cable grounding kit assembling on page 98
![Page 52: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/52.jpg)
ED 05 3DB 06687 DAAA 52/178
INDOOR UNIT
TYPE N CONNECTOR
Rear s ide GROUNDING POINT
-
7-8GHz
13-38GHz
Colson Cable ties
Grounding See NOTE B and C
See NOTE A/3
See NOTE A/3
Rack (Shelf or Desktop – See NOTE A/4
7-8GHz
Figure 19 - Typical installation of 1+1 ODU with integrated antenna, 30 cm or 60 cm.
NOTE A:
1) The cable is fixed along the supporting pipe or pole by the normal methods (Colson cable ties are supplied in the optional consumables kit)
2) see NOTE B 3) The rack can be connected to ground using the top or the bottom side grounding points. 4) For the installation on shelf or desktop the indoor unit must be connected to ground using the
rear side grounding point.
NOTE B: Coaxial cable grounding Kit
First in proximity of ODU Second in proximity of building access In case of cable length over 80 m, the cable grounding kit must be implemented every 40 meter cable distance.
NOTE C: see par. 4.14 IDU / ODU cable grounding kit assembling on page 98
![Page 53: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/53.jpg)
ED 05 3DB 06687 DAAA 53/178
INDOOR UNIT
WAVEGUIDE
WAVEGUIDE FLANGE
ANTENNA FLANGE
GROUND CABLE
ANTENNA GROUNDING
GROUNDING KIT
(
)
Rear side GROUNDING POI NT
-
POLE
Colson Cable ties
Type N Connector
GROUNDING See NOTE B and C
Rack (Shelf or Desktop – See NOTE A/4)
See NOTE A/3
See NOTE A/3
Figure 20 - Typical install. of 1+0 ODU with non integrated antenna and the 600 mm.
flexible twist or optimized Wave-guide length NOTE A:
1) The cable is fixed along the supporting pipe or pole by the normal methods (Colson cable ties are supplied in the optional consumables kit)
2) see NOTE B 3) The rack can be connected to ground using the top or the bottom side grounding points. 4) For the installation on shelf or desktop the indoor unit must be connected to ground using the
rear side grounding point.
NOTE B: Coaxial cable grounding Kit
First in proximity of ODU Second in proximity of building access In case of cable length over 80 m, the cable grounding kit must be implemented every 40 meter cable distance. NOTE C: see par. 4.14 IDU / ODU cable grounding kit assembling on page 98
![Page 54: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/54.jpg)
ED 05 3DB 06687 DAAA 54/178
INDOOR UNIT
POLE
WAVEGUIDE
WAVEGUIDE FLANGE
ANTENNA FLANGE
GROUND CABLE
FLEX TWIST or WAVE GUIDE
GROUNDING KIT R 3
POLE
)
Rear side
GROUNDING POINT
RACK (SHELF or DESKTOP - SEE NOTE 4)
Available only for 38 GHz for lower frequency Flex-twist use plastic streaps
GROUNDING See NOTE B and C
See NOTE A/3
See NOTE A/3
7-8GHz
13-38GHz
Figure 21 - Typical install. of 1+1 ODU with non integrated antenna and the 600 mm. flexible twist or optimized Wave-guide length
NOTE A:
1) The cable is fixed along the supporting pipe or pole by the normal methods (Colson cable ties are supplied in the optional consumables kit)
2) see NOTE B 3) The rack can be connected to ground using the top or the bottom side grounding points. 4) For the installation on shelf or desktop the indoor unit must be connected to ground using the
rear side grounding point.
NOTE B: Coaxial cable grounding Kit
First in prossimity of ODU Second in proximity of building access In case of cable length over 80 m, the cable grounding kit must be implemented every 40 meter cable distance. NOTE C: see par. 4.14 IDU / ODU cable grounding kit assembling on page 98
![Page 55: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/55.jpg)
ED 05 3DB 06687 DAAA 55/178
4.4. 1+0 ODU configuration Installation with integrated antenna
4.4.1. Required Parts
- Integrated antenna
- Antenna Mounting Hardware
- Pole Mounting Assembly
- Outdoor Unit and mounting hardware.
4.4.2. Pole mounting assembly
This assembly is valid only for integrated antenna diameters up to 0.6 m (two feet). The integrated antenna is mounted on the pole front. The outdoor “pole mounting“ system is designed for quick mechanical installation.
43
2
1
56
1) ODU radio (and detail of horizontal polarization) 2) U Bolts For Pole diameter from 90 mm up to 114 mm 3) Screws to fasten antenna to support 4) Antenna screw-fastening slots 5) Integrated Antenna (and detail of horizontal polarization) 6) Radio mounting
N.B.: To avoid equipment damage the bolt tightening torque for fixing the bolts (3) to antenna slots (4) must be 80 kg x cm (8 Newton x m) (5.76 lb.ft). For U-bolts (2) the bolt tightening torque must be 342,3 kg x cm (33,55 Newton x m) (24.65 lb.ft). Exceeding this value may result in bolt breaking.
Figure 22 - Integrated pole mounting with ODU 1+0, Horizontal Polarization
![Page 56: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/56.jpg)
ED 05 3DB 06687 DAAA 56/178
Figure 23 - Integrated antenna pole mounting with ODU 1+0, Vertical Polarization
![Page 57: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/57.jpg)
ED 05 3DB 06687 DAAA 57/178
Figure 24 – 7-8 GHz Integrated antenna pole mounting with ODU 1+0, Vertical Polarization
The mechanical system can be secured to any fixing pole with a diameter of between 90 and 114 mm. A pole diameter of 114 mm is, however, recommended. With smaller diameters, mounting is possible, if special attention is paid to the mechanical rigidity of the assembly. There are also supports for fixing the pole to the wall: please consult us.
Various antenna types and sizes can be used, together with radio systems operating at different frequencies and in a variety of configurations.
![Page 58: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/58.jpg)
ED 05 3DB 06687 DAAA 58/178
4.4.3. General Procedural Sequence:
- Install the pole mounting assembly on mast; see paragraph 4.4.5. - Turn the Antenna Nose according to the Hop polarization see paragraph 4.4.6. - Install the antenna on pole mounting, see paragraph 4.4.6. - Install the ODU; see paragraph 4.4.7 - Pre-point the antenna; see paragraph 4.4.8 Alternative possibility: - Install Antenna on pole mounting - Turn Antenna nose - Install pole mounting with Antenna - Prepoint Antenna - Install ODU
4.4.4. Procedure note
NOTE: When attaching the antenna, ODU mounting hooks, and ODU, adhere to the following:
- position the antenna with the drain hole to the bottom,
- remove the antenna node protecting plug and position the antenna node wide dimension horizontal for vertical polarization or vertical for horizontal polarization,
- position the ODU fastening hooks and the ODU horizontal for vertical polarization or vertical for horizontal polarization.
4.4.5. Installing the “pole mounting“ on mast
- Position the U bolts (2) on the pole fit the flat washers, “growe“ washers, nuts and lock nuts (1). - Point the pole mounting in the required direction using a compass and a pair of binoculars, and then
secure the brackets.
1
2
N.B.: For U-bolts the bolt tightening torque must be 342.3 kg x cm (33.55 Newton x m)(24.65 lb.ft).Exceeding this value may result in bolt breaking
Figure 25 - Pole mounting installation for integrated antenna
![Page 59: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/59.jpg)
ED 05 3DB 06687 DAAA 59/178
4.4.6. Installing the antenna on the pole mounting
Turn the Antenna Nose according to the Hop polarization - Before to position the antenna vertically (node assembling ), with the drain hole in the bottom part and
free of obstacles. - Insert the M6 screws (7 in all) (1) with their “onduflex“ springy crinkle washers, tighten and secure the
screws.
Socket cap torque
Socket cap torque
Socket cap torque
Silicon grease
NB. : To turn the Antenna polarization, loose the 3 Socket cap screw and turn 90° the Nose, tight the screw NB. : Before inserting the ODU onto the Nose, apply the sullied gel on the O-ring
Figure 26 - Change polarisation description
The antennas are normally supplied with vertical polarization. To change the polarization: undo the three socket cap torque and turn the nose through 90 degrees then tighten the screws again. (See Figure 27 on page 59).
Figure 27 - Installation with integrated antenna and Vertical polarization
![Page 60: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/60.jpg)
ED 05 3DB 06687 DAAA 60/178
4.4.7. Installing the ODU
- Remove the solar shield by unscrewing the two solar shield screws - Grasp the ODU module by the handle. - Open the four looking hooks (1) arranged on the four walls of the ODU unit - Rotate the ODU depending to horizontal or vertical polarization, - Plug-in insert the specific brackets (2) to the support (Radio mounting), - WARNING: is mandatory to fix the four looking hooks like indicated and that is on the
binary inside - Secure the ODU module through the four hooks (1) on the relative brackets (2). - Reinstall the solar shield onto the RT by screwing on it the two solar shield screws
1
2
GROUNDING POINT
GROUNDING POINT UP
GROUNDING POINT DOWN
2
2
Figure 28 - ODU 1+0 installation for integrated antenna
REMINDER: The ODU/antenna assembly requires no additional seal on the SHF flanges; the two ends are smooth. The O-ring seal around the male “noses” provides sealing. NB: Before to connect the ODU it is mandatory to put SILICONE grease on the O-ring.
![Page 61: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/61.jpg)
ED 05 3DB 06687 DAAA 61/178
4.4.8. Pointing the antenna
4.4.8.1. Pole mounting types
3CC10752ABAA 3CC10752ABAB
Figure 29 – Pole mounting types
4.4.8.2. Antenna mechanical pre-pointing
Overall antenna steer (with turnbuckles set to the “maximum“) is: - Bearing: 360 degrees for 30 cm and 60 cm diameter antenna,
The steer obtained by the turnbuckles is: - Elevation: + 25° degrees, - Bearing: + 10° degrees.
Figure 30 – Stretching screw (3CC14292AAAA)
![Page 62: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/62.jpg)
ED 05 3DB 06687 DAAA 62/178
Figure 31 – Pole mounting without Stretching screw inserted
Figure 32 – Stretching screw inserted (Vertical alignment)
F1-F2-F3 Vertical position coarse alignment movement tighten screw A Vertical position rotational axis B Vertical fine alignment nut mouvement (Stretching screw)
F1 F2 F3
AB
![Page 63: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/63.jpg)
ED 05 3DB 06687 DAAA 63/178
C
D
E
C1 D1
Figure 33 – Integrated pole mounting (Horizontal alignment) C Horizontal position rotational axis C1 Horizontal position rotational axis (under) D Horizontal position coarse alignment movement tighten screw D1 Horizontal position coarse alignment movement tighten screw (under) E Bolts First horizontal pre-pointing (azimuth)
Horizontally place the antenna according to the direction set down in the “plant documents“ where, among the various indication are indicated those concerning the “reference points“ (Position of the tower or of the building with respect to true north) in order to point the antenna in the set direction. There are various procedures and technical means to adopt in order to mechanically pre-point the antenna, and they can be implemented in various ways according to the various configurations and to the various system conditions. The standard instrumentation is the - compass.
Second vertical pre-pointing (zenith)
Place the antenna vertically nearest to its operating angle. The technical and operative procedure adopted to vertically point the antenna is as that previously implemented to horizontally pre-point.
Note
a ) At the end of the pre-pointing operation, slowly block all the horizontal and vertical regulating system of the antenna taking care not to modify dish direction
b ) Final antenna pointing (or connection) shall be established only after all the Antenna and ODU system is fully installed.
c) After the fine pointing TIGHTENING TORQUE FOR THE SCREWS OF M10 IS OF 30Nm (ScrewsA - C- C1- D- D - F1 - F2- F3) NOTE: for more information see the “9400AWY REL.2.0 – User Manual/Line Up Guide
![Page 64: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/64.jpg)
ED 05 3DB 06687 DAAA 64/178
4.4.9. Installation on the wall information
Note: In certain pole mounting installation circumstances, due to various reasons such as protrusions from the wall, it might be useful to mount as shown on page 64 in order to easily install ODU module.
WALL
POLE
Figure 34 - Pole mounting near a wall
![Page 65: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/65.jpg)
ED 05 3DB 06687 DAAA 65/178
4.4.10. Antenna 3 / 4 Feet Installation Instructions
The instructions for the assemblage of the antenna are normally contained in the box of the same antenna. Following are shown only some examples of assemblage of antennas
V
H
Figure 35 – 3 Feet Antenna (Configuration 1+0)
![Page 66: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/66.jpg)
ED 05 3DB 06687 DAAA 66/178
V
H
Figure 36- 4 Feet Antenna (Configuration 1+0)
![Page 67: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/67.jpg)
ED 05 3DB 06687 DAAA 67/178
4.5. 13-38GHz - 1+1 ODU configuration Installation with integrated antenna
4.5.1. Required Parts Listing
- Integrated antenna - Antenna Mounting Hardware . - Pole Mounting Assembly - Outdoor Unit and mounting hardware.
1
2
3
4
5
6
7
8
8 Silicon grease
Silicon grease
Figure 37 - Typical installation pole mounting with ODU 1+1 for integrated antenna 1) U bolts 2) Pole mounting 3) Radio mounting 4) Fastening points for COUPLER 5) Screws fastening the antenna to the support 6) Antenna screw-fastening slots 7) RF Coupler Fastening brackets for ODU 8) Grounding points
N.B.: To avoid equipment damage the bolt tightening torque for fixing the bolts (5) to antenna slots (6) must be 80 kg x cm (8 Newton x m) (5.76 lb.ft). For U-bolts (1) the bolt tightening torque must be 342.3 kg x cm (33.55 Newton x m) (24.65 lb.ft). Exceeding this value may result in bolt breaking.
![Page 68: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/68.jpg)
ED 05 3DB 06687 DAAA 68/178
4.5.2. 13-38GHz - 1+1 Typical installation (General Procedural Sequence)
- Install the pole mounting assembly on mast; see paragraph 4.4.5; - Install the antenna on the pole mounting, see paragraph 4.4.6; - Install the Coupler, see paragraph 4.5.2.1; - Install the ODU, see paragraph 4.5.2.2; - Point the antenna, see paragraph 4.4.8.
4.5.2.1. Installing the coupler
Grasp the coupler by the handle. Fasten the coupler to the support through the four locking hooks (1) that will be tightened onto the relative fastening brackets on the radio support (2). The reference in Figure 38 is important for the correct installation of the coupler Ththe label corresponds to the side of the pole
1
2
P I P E
MAIN ACCESSSide
Pole
Figure 38 - Installing the Coupler To the Radio Support
![Page 69: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/69.jpg)
ED 05 3DB 06687 DAAA 69/178
4.5.2.2. 13-38GHz - Installing the ODU 1+1
Grasp two modules ODU by the handle. Fasten the ODU module to the support through the locking hooks (1-2-3-4) that will be tightened onto the relative fastening bracket on the coupler.
Procedure to install the ODU modules
ODU A : hooks (1), hooks (2), hooks (3), hooks (4)
ODU B : hooks (1), hooks (2), hooks (3), hooks (4)
ODU A
Fastening brackets
ODU B
Locking hooks 3
4
1
2
3
4
1
2
Figure 39 - Installing the RF coupler with ODU 1+1 for integrated antenna
![Page 70: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/70.jpg)
ED 05 3DB 06687 DAAA 70/178
4.5.3. 13-38GHz Change polarization in 1+1 configuration
The axial adaptation between H polarization to V polarization (and viceversa) is a mechanical/electrical adjustment. Every mechanical “STEP” is 30° adjustment.
1st Step
2nd Step
Figure 40 – 1st Step and 2nd step
4.5.3.1. Change Polarization Procedure
1st Step = internal 30° rotate Coupler body
1st Step Rotate 30°
Figure 41 – 1st Step inserted
![Page 71: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/71.jpg)
ED 05 3DB 06687 DAAA 71/178
2nd Step= cover + screws 60°( 30°+ 30°) rotate Coupler body
2st Step Rotate 60°
Figure 42 – 2nd Step inserted The “spigot” in the Integrated Antenna configuration is 30° and complete the change of polarization (90°).
Figure 43 – Screws fixing
![Page 72: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/72.jpg)
ED 05 3DB 06687 DAAA 72/178
4.6. 7- 8GHz 1+1 ODU configuration Installation with integrated antenna (Alternative A)
4.6.1. Required Parts Listing
- Integrated antenna - Antenna Mounting Hardware . - Pole Mounting Assembly - Coupler - Outdoor Unit and mounting hardware.
MAIN ACCESS
Silicon greeze has to be added on the O-ring
Figure 44 - Typical installation pole mounting with ODU 1+1 for integrated antenna (7-8GHz)
![Page 73: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/73.jpg)
ED 05 3DB 06687 DAAA 73/178
4.6.2. 7- 8GHz 1+1 Typical installation (General Procedural Sequence)
- Install the pole mounting assembly on mast; see paragraph 4.4.5; - Install the antenna on the pole mounting, see paragraph 4.4.6; - Install the Coupler, see paragraph 4.6.2.1; - Install the ODU, see paragraph 4.6.2.2; - Point the antenna, see paragraph 4.4.8.
4.6.2.1. Installing the coupler
Grasp the coupler by the handle. Fasten the coupler to the support through the four locking hooks (1) that will be tightened onto the relative fastening brackets on the radio support (2). The reference in Figure 54 is important for the correct installation of the coupler Ththe label corresponds to the side of the pole
Figure 45 - Installing the Coupler To the Radio Support
MAIN ACCESS
Silicon greeze
![Page 74: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/74.jpg)
ED 05 3DB 06687 DAAA 74/178
4.6.2.2. Installing the ODU 1+1
Grasp two modules ODU by the handle. Fasten the ODU module to the support through the locking hooks (1-2-3-4) that will be tightened onto the relative fastening bracket on the coupler.
Procedure to install the ODU modules
NB: Before to connect the ODU warn about the fact the Silicone greeze has to be added on the O-ring.
ODU A :(SPARE) hooks (A1), hooks (A2), hooks (A3), hooks (A4)
ODU B (MAIN) : hooks (B1), hooks (B2), hooks (B3), hooks (B4)
A
B
M A I N
A1
A2
A3 A4
B1
B2
B3B4
Silicon greeze
Figure 46 - Installing the RF coupler with ODU 1+1 for integrated antenna
Silicon greeze
![Page 75: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/75.jpg)
ED 05 3DB 06687 DAAA 75/178
4.6.3. 7- 8GHz Change polarization in 1+1 configuration
Change Polarization procedure Vertical Polarization to Horizontal Polarization The point of reference is on the position V (vertical Polarization) To change the polarization needs to perform the following operations: To unscrew the three screws To turn the thin twist and to make to coincide the position H to the point of reference "Á." To screw the screws Horizontal Polarization to Vertical Polarization The point of reference is on the position H (horizontal Polarization) To change the polarization needs to perform the following operations: To unscrew the three screws To turn the thin twist and to make to coincide the position H to the point of reference "A" To screw the screws Detail B
See Detail B See Detail A
Detail A
Screw
Screw
TWIST
Point of reference
“A”
Point of reference
“A”
Figure 47 – 7 – 8GHz Change Polarization
![Page 76: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/76.jpg)
ED 05 3DB 06687 DAAA 76/178
4.7. 7- 8GHz 1+1 ODU configuration Installation with integrated antenna (Alternative B)
4.7.1. Required Parts Listing
- Integrated antenna - Antenna Mounting Hardware . - Pole Mounting Assembly - Coupler - Outdoor Unit and mounting hardware.
MAIN
MAIN
Figure 48 - Typical installation pole mounting with ODU 1+1 for integrated antenna (7-8GHz)
![Page 77: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/77.jpg)
ED 05 3DB 06687 DAAA 77/178
4.7.2. 7- 8GHz 1+1 Typical installation (General Procedure Sequence)
- Install the pole mounting assembly on mast; see paragraph 4.4.5; - Install the antenna on the pole mounting, see paragraph 4.4.6; - Install the Coupler, see paragraph 4.7.2.1; - Install the ODU, see paragraph 4.7.2.2; - Point the antenna, see paragraph 4.4.8.
4.7.2.1. Installing the coupler
MAIN
MAIN
MAIN
Figure 49 – 7- 8GHz Coupler (Alternative B) Grasp the coupler by the handle. Fasten the coupler to the support through the four locking hooks (1) that will be tightened onto the relative fastening brackets on the radio support (2). The reference in Figure 50 is important for the correct installation of the coupler The label corresponds to the side of the pole
1 2
MAIN
Figure 50 - Installing the Coupler To the Radio Support
![Page 78: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/78.jpg)
ED 05 3DB 06687 DAAA 78/178
4.7.2.2. Installing the ODU 1+1
Grasp two modules ODU by the handle. Fasten the ODU module to the support through the locking hooks (1-2-3-4) that will be tightened onto the relative fastening bracket on the coupler. Procedure to install the ODU modules NB: Before to connect the ODU it is mandatory to put SILICONE grease on the ing. ODU A (MAIN) ODU B :(SPARE) ( hooks (B1), hooks (B2), hooks (B3), hooks (4)
ODU B - ODU B – Hook 1
ODU B – Hook 1 fixing ODU B – Hook 1 fixed
ODU B – Hook 2 Fixing ODU B – Hook 2 Fixed
ODU B - Fixed ODU A and ODU B Fixed on the Coupler with Solar
shield
Figure 51 - Installing the RF coupler with ODU 1+1 for integrated antenna
![Page 79: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/79.jpg)
ED 05 3DB 06687 DAAA 79/178
7- 8GHz Change polarization in 1+1 configuration
Change Polarization procedure Vertical Polarization to Horizontal Polarization The point of reference is on the position V (vertical Polarization) To change the polarization needs to perform the following operations: • to unscrew the two screws • to turn the thin twist and to make to coincide the position H • to screw the screws Horizontal Polarization to Vertical Polarization The point of reference is on the position H (horizontal Polarization) To change the polarization needs to perform the following operations: • to unscrew the two screws • to turn the thin twist and to make to coincide the position V • to screw the screws
Figure 52 – 7 – 8GHz Change Polarization
Screw
Polarization V
Screw
Polarization H
![Page 80: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/80.jpg)
ED 05 3DB 06687 DAAA 80/178
4.8. 1+0 ODU configuration Installation with non-integrated antenna
4.8.1. Required Parts Listing
- Non Integrated antenna - Antenna Mounting Hardware and instructions (supplied by manufacturer). - Pole Mounting Assembly - Outdoor Unit and mounting hardware. - Flexible waveguide, gaskets, and fasteners or standard waveguide and flanges.
Figure 53 - Pole mounting installation for not integrated antenna with ODU 1+0 NB: Pole mounting can be installed on the Right or Left hand side of the pole.
4.8.2. General Procedural Sequence
- Install the antenna on the mast, according to the instructions given by the manufacturer and supplied with the antenna, and prepoint the antenna towards the remote station;
- install the pole mounting on the mast, see paragraph 4.8.3; - install the ODU, see paragraph 4.8.3.2; - install the flextwist (suited to the frequency) between the Pole M. Nose adaptor and the antenna Nose
Adaptor, see paragraph 4.8.5.
![Page 81: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/81.jpg)
ED 05 3DB 06687 DAAA 81/178
4.8.3. Install the pole mounting on the mast.
4.8.3.1. Pole mounting assembly
This assembly is valid only for non-integrated antenna.
The outdoor “pole mounting“ system is designed for quick mechanical installation. The mechanical system can be secured to any fixing pole with a diameter of between 90 and 114 mm. A pole diameter of 114 mm is, however, recommended. With smaller diameters, mounting is possible, if special attention is paid to the mechanical rigidity of the assembly. There are also supports for fixing the pole to the wall: please consult us. Various antenna types and sizes can be used, together with radio systems operating at different frequencies and in a variety of configurations.
4.8.3.2. Installing the “pole mounting“
1
Figure 54 - Installation of the pole mounting for not integrated antenna
NB: Pole mounting can be installed on the Right or Left hand side of the pole.
- Position the Pole mounting support on the pole side as shown in the plant documentation. - Position the U bolts (1) on the pole, fit the flat washers, “growe“ washers, nuts and lock nuts (2). - Point the pole mounting in the required direction using a compass and a pair of binoculars, and then
secure the brackets. - To change the polarization: undo the three socket cap screws and turn the nose through 90 degrees
then tighten the screws again. See Figure 27 on page 59.
N.B.: For U-bolts (1) the bolt tightening torque must be 342.3 kg x cm (33.55 Newton x m)(24.65 lb.ft). Exceeding this value may result in bolt breaking.
![Page 82: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/82.jpg)
ED 05 3DB 06687 DAAA 82/178
4.8.4. Installing the ODU
NB: Pole mounting can be installed on the Right or Left hand side of the pole.
- Take off the solar shield by unscrewing the two screws placed on the solar shield back panel. - Grasp the ODU module by the handle. Open the four looking hooks (1) arranged on the four walls of
the ODU unit - Position the Pole mounting support on the pole side as shown in the plant documentation. - Position the ODU for desired polarization (horizontal or vertical), - Connect the specific brackets (2) to the support (Radio mounting), - Secure the ODU module through the four hooks (1) onto the relative brackets (2). - Put back the solar shield by screwing the two screws placed on the solar shield back panel.
1
2
Figure 55 - ODU 1+0 installation for not integrated antenna
REMINDER: The ODU/antenna assembly requires no additional seal on the SHF flanges; the two ends are smooth. The O-ring seal around the male “noses” provides sealing.
![Page 83: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/83.jpg)
ED 05 3DB 06687 DAAA 83/178
4.8.5. Installing the “Flextwist“ waveguide
The long twistable flexible waveguide is supplied complete with gaskets and fasteners. At one end, it has a smooth square flange (to be mounted on the antenna) and at the other end, a grooved square flange designed to accommodate an O-ring seal (mounted at the ODU end).
Table 15 - 7-8Ghz FLEXTWIST WAVEGUIDE
FLEXIBLE TWISTABLE WAVEGUIDE KIT
Alcatel code Waveguide Lenght. mm.
Freq.Band Ghz. Flanges
Stainless steel
socket cap
screws
Stainless steel
socket cap
screws
“Ondulflex” springy crinkle
washers
Stainless Z. flat
washers
HM. Hex nuts
1AF11977AAXX WR112 1.000 7,05 - 10 PDR84 UDR84 12 (M4x25)
8 (M4x20)
12 (B4) 12 (Z4) 12 (HM4)
3CC08010ABAB (Note A)
WR112 1.000 7,05 - 10 PBR84 UBR84 8 (M4x25)
8 (M4x12)
8 (B4) 8 (Z4) 8 (HM4)
Note A: next introduction in substituition of 1AF11977AAXX
Table 16 - 13-38Ghz FLEXTWIST WAVEGUIDE
FLEXIBLE TWSITABLE WAVEGUIDE KIT
Alcatel code Waveguide Lenght. mm.
Freq.Band Ghz.
Flanges Stainless steel
socket cap
screws
Stainless steel
socket cap
screws
“Ondulflex” springy crinkle
washers
Stainless Z. flat
washers
HM. Hex nuts
3CC05751ACAA WR75 600 10 – 15,0 PBR120 UBR120 8 (M4x20)
8 (M4x12)
8 (B4) 12 (Z4) 12 (HM4)
3CC05750ACAA WR62 600 12,4 - 18 PBR140 UBR140 8 (M4x20)
8 (M4x12)
8 (B4) 8 (Z4) 8 (HM4)
3CC05749ACAA WR42 600 18 – 26,5 PBR220 UBR220 8 (M3x20)
8 (M3x12)
8 (B3) 8 (Z3) 8 (HM3)
3DB00682AAAA WR28 600 26,5 – 40 PBR320 UBR320 8 (M3x20)
8 (M3x12)
8 (B3) 8 (Z3) 8 (HM3)
Note: If the FLEX-TWIST is not provided by Alcatel, the user must carefully choose the type of the connection guide in order to limit as much as possible galvanic couples between ANTENNA/flex-twist and flex-twist/ODU contact surfaces that can induce rust. For this purpose pleae note that the surfaces are:
- chromium-plated at ODU’s output flange side
- tin-plated at flex-twist’s flange side
![Page 84: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/84.jpg)
ED 05 3DB 06687 DAAA 84/178
4.9. 13-38GHz - 1+1 ODU configuration Installation with non-integrated antenna
Figure 56 on page 84 shows the pole mounting assembling with ODU 1+1 unit.
4.9.1. Required Parts Listing
- Non-integrated antenna - Antenna mounting hardware and instructions (supplied by manufacturer) - Pole Mounting Assembly - RF Coupler - Outdoor unit and mounting hardware - Flexible waveguide, gaskets, and fasteners
4.9.2. General Procedural Sequence
- Install the antenna on the mast, according to the instructions given by the manufacturer and supplied with the antenna, and prepoint towards the remote station using a compass and pair of binoculars;
- Install the pole mounting on the mast; see paragraph 4.8.3; - Install the RF Coupler - Install the ODU; see paragraph 4.9.3.1; - Install the flextwist (suited to the frequency) between the pole mounting nose adaptor and the to
antenna flange.
1
A
B
Figure 56 - Pole mounting with ODU 1+1 for not integrated antenna (13 to 38 GHz)
NB: It is highly recommended tu put SILICONE grease on the O-ring of the antenna nose before the assembly with the coupler (see point A). The same rule is applicable for the O-ring of the coupler (see point B).
N.B.: For U-bolts (1) the bolt tightening torque must be 342.3 kg x cm (33.55 Newton x m)(24.65 lb.ft). Exceeding this value may result in bolt breaking.
![Page 85: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/85.jpg)
ED 05 3DB 06687 DAAA 85/178
4.9.3. Installing the Coupler
- Grasp the coupler by the handle. Fasten the coupler to the support through the four locking hooks (1) that will be tightened onto the relative fastening brackets on the radio support (2).
1
2 Silicone grease
Figure 57 - Installation of the Coupler on the pole mounting (13 to 38 GHz)
4.9.3.1. Install the ODU
- Grasp two modules ODU by the handle. Fasten the ODU module to the support through the locking hooks (3) that will be tightened onto the relative fastening bracket on the coupler (4).
- Reinstall the solar shield onto the ODU.
O D U
4
O D U
3
Figure 58 - Installation of ODU 1+1 on the pole mounting for not integrated antenna (11 to 38 GHz)
![Page 86: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/86.jpg)
ED 05 3DB 06687 DAAA 86/178
4.10. 7- 8GHz - 1+1 ODU configuration Installation with non-integrated antenna (Alternative A)
Figure 59 - Pole mounting ODU 1+1 for not integrated antenna
with Nose Adapter (7 - 8GHz) – 3DB01459AAAA
Figure 60 - Pole mounting ODU 1+1 for not integrated antenna
Nose Adapter (7 - 8GHz) – 3DB10136AAAA
Nose Adapter
![Page 87: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/87.jpg)
ED 05 3DB 06687 DAAA 87/178
4.10.1. Required Parts Listing
- Non-integrated antenna - Antenna mounting hardware and instructions (supplied by manufacturer) - Pole Mounting Assembly - RF Coupler - Nose Adapter - Outdoor unit and mounting hardware - Flexible waveguide, gaskets, and fasteners
4.10.2. General Procedural Sequence
- Install the antenna on the mast, according to the instructions given by the manufacturer and supplied with the antenna, and prepoint towards the remote station using a compass and pair of binoculars;
- Install the pole mounting on the mast; see paragraph 4.8.3; - Install the RF Coupler 4.10.3 - Install the ODU; see paragraph 4.10.3.1; - Install the flextwist (suited to the frequency) between the pole mounting nose adaptor and the to
antenna flange.
4.10.3. Installing the Coupler
Grasp the coupler by the handle. Fasten the coupler to the support through the four locking hooks (1) that will be tightened onto the relative fastening brackets on the radio support (2).
1
2
![Page 88: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/88.jpg)
ED 05 3DB 06687 DAAA 88/178
MA
IN
ACC
ESS
MAIN
Figure 61 - Pole mounting/RF COUPLER 1+1 for not integrated antenna (7 - 8GHz)
![Page 89: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/89.jpg)
ED 05 3DB 06687 DAAA 89/178
4.10.3.1. Install the ODU
- Grasp two modules ODU by the handle. Fasten the ODU module to the support through the locking hooks (3) that will be tightened onto the relative fastening bracket on the coupler (4). Reinstall the solar shield onto the ODU.
MAIN3
4
Solar
shields
Figure 62 - Installation of ODU 1+1 on the pole mounting for not integrated antenna (7- 8 GHz)
![Page 90: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/90.jpg)
ED 05 3DB 06687 DAAA 90/178
4.11. 7-8GHz – Installation Full Indoor AWY (Two Terminal) For 7.8GHz an indoor installation of transceiver is available and hereafter described:
Figure 63 – Panel support 4U – 19“ for ODU 1+1 and Coupler
(Horizontal position)
1
2
3
8
7
4
![Page 91: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/91.jpg)
ED 05 3DB 06687 DAAA 91/178
8
1
2
9
To IDU
5 7
Figure 64 – Panel support 4U – 19“ for ODU 1+1 and Coupler
(Vertical position)
![Page 92: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/92.jpg)
ED 05 3DB 06687 DAAA 92/178
Figure 65 – Principle Installation in Laborack with ODU 1+1 and Coupler
To antenna Station A
To antenna Station C
IDU 1+1 Station A
IDU 1+1 Station C
ODU 1+1
ODU 1+1
DehydratoR
4
3
8
11
![Page 93: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/93.jpg)
ED 05 3DB 06687 DAAA 93/178
Figure 66 – Support pole mounting (Laborack)
Ref. Description Code 1 RF Coupler 7/8 GHz 3CC14536AAAA 2 Adapter nose 3DB10135AAXX
3 Casted piece ODU socket restart 3DB10137AAAA 4 Flextwist PDR84/UBR 84L: 1000 mmm 3CC08010ABXX
5 FSJ1-50A coax.feed.NM right angl/NMLg3m 3CC09514AAAA
6 Cabinet grounding kit Y/G for IDU 3CC13423AAAA
7 Laborack 1AD114560001 8 Fixation support ODU 1+1 in rack 3CC50023AAAA 9 Grounding kit for support ODU 3CC08166ABAA
10 Consummable kit 3CC06503AAXX 11 Dehydrator 1AF01052AAAA
Table 17 - AWY 7/8 GHz Installation code Full Indoor housing kit
3
![Page 94: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/94.jpg)
ED 05 3DB 06687 DAAA 94/178
4.12. 7- 8GHz - 1+1 ODU configuration Installation with non-integrated antenna (Alternative B)
MAIN
Figure 67 - Pole mounting ODU 1+1 for not integrated antenna (7 - 8GHz)
4.12.1. Required Parts Listing
- Non-integrated antenna - Antenna mounting hardware and instructions (supplied by manufacturer) - Pole Mounting Assembly - RF Coupler - Nose Adapter (see Figure 60) - Outdoor unit and mounting hardware - Flexible waveguide, gaskets, and fasteners
4.12.2. General Procedural Sequence
- Install the antenna on the mast, according to the instructions given by the manufacturer and supplied with the antenna, and prepoint towards the remote station using a compass and pair of binoculars;
- Install the pole mounting on the mast; see paragraph 4.8.3; - Install the RF Coupler 4.12.3 - Install the ODU; see paragraph 4.12.3.1; - Install the flextwist (suited to the frequency) between the pole mounting nose adaptor and the to
antenna flange.
MAIN
![Page 95: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/95.jpg)
ED 05 3DB 06687 DAAA 95/178
4.12.3. Installing the Coupler
Grasp the coupler by the handle. Fasten the coupler to the support through the four locking hooks (1) that will be tightened onto the relative fastening brackets on the radio support (2).
1
2
Figure 68 - Pole mounting/RF COUPLER 1+1 for not integrated antenna (7 - 8GHz)
![Page 96: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/96.jpg)
ED 05 3DB 06687 DAAA 96/178
4.12.3.1. Install the ODU
- Grasp two modules ODU by the handle. Fasten the ODU module to the support through the locking hooks (1) that will be tightened onto the relative fastening bracket on the coupler (2). Reinstall the solar shield onto the ODU.
1
2
MAIN
1
2
Coupler
O D U
Figure 69 - Installation of ODU 1+1 on the pole mounting for not integrated antenna (7- 8 GHz)
MAIN
![Page 97: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/97.jpg)
ED 05 3DB 06687 DAAA 97/178
4.13. Solar shield Installation Figure 70 on page 97 shows the solar shield mounting example (using screws) for ODU 1+0. The same procedure applies to the 1+1 configuration.
NB. Solar shield has to be installed only after ODU installation.
V
H
H
V
Solar shield – Polarization V Solar shield – Polarization H
The ARROW determines the polarization
Figure 70 - Solar shield installation ODU 1+0
Solar shield screws
In vertical or horizontal polarization, the solar shield remains fixed in the same position and the ODU is the only part which can rotate 90 degrees when changing the polarization.
![Page 98: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/98.jpg)
ED 05 3DB 06687 DAAA 98/178
4.14. IDU / ODU cable grounding kit assembling
Cable grounding kit assembling description:
Cable reference type: Ref: FILOTEX COAX CABLE 50ohm (1AC001100022)
Cable reference table:
![Page 99: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/99.jpg)
ED 05 3DB 06687 DAAA 99/178
![Page 100: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/100.jpg)
ED 05 3DB 06687 DAAA 100/178
5. INDOOR UNITS INSTALLATION (IDU)
5.1. General
Indoor units (IDU) of the 9400 AWY system can be installed in different ways as described below: - Installation in a ETSI (WTD) rack (21") and North American standard rack (21") (see paragraph 5.2.1
on page 100) or Laborack (see paragraph 5.2.2 on page 104); - Installation in a 19" DIN rack (see paragraph 5.2.3 on page 105); - Installation on masonry wall (see paragraph 5.4 on page 109).
For each of the above type of installation special mechanical supporting fixtures are available.
Table 14 -.on page 45 gives a list of the installation materials that are included in the catalogue.
5.2. Rack mount kit description Special mechanical fittings are provided for this type of installation, depending to the width of rack (19" or 21"). In the paragraph 5.2.1 on page 100 the figures examples shown the fittings used to insert the equipment in ETSI racks (21"). These examples are also present in paragraph 5.2.3 on page 104 for installation in 19" DIN racks by changing the adaptors.
5.2.1. Rack mount installation in ETSI (WTD) and North American standard rack.
For the 1+0 and 1+1 configuration the mechanical fittings are shown in the assembly drawing of Figure 71 on page 101..
The Figure 72 on page 102 shows the types of subrack installation into the rack. The Figure 73 on page 103 shows the typical WTD rack installation with 1+0 and 1+1 equipment.
The
Figure 74 on page 103 shows the coaxial minidistributor wiring.
![Page 101: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/101.jpg)
ED 05 3DB 06687 DAAA 101/178
Example of 1+0 IDu with 21" supports for rack mounting
Example of 1+1 IDu with 21" supports for rack mounting
Figure 71 - Example of 1+0 and 1+1 IDU with 21" supports for rack mounting
T.R.U TOP RACK UNIT
![Page 102: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/102.jpg)
ED 05 3DB 06687 DAAA 102/178
Detail A - Screw hole
Detail B - Nut cage
A B
B
Detail ADetail B
Figure 72 - Subrack installation in 21" rack
![Page 103: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/103.jpg)
ED 05 3DB 06687 DAAA 103/178
Figure 73 –View of installation
Figure 74 - Wired mini distributor
![Page 104: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/104.jpg)
ED 05 3DB 06687 DAAA 104/178
5.2.2. Laborack
The laborack dimensons are:
• Height 2065 mm • Width 545mm • Depth 400mm
Ref: 1AD114560001
Figure 75 - Laborack
IDU Installation in Laborack When you have correctly positioned the fixing brackets on the 19” unit, the front panel will hold the equipment by four screws fitted into the laborack cage nuts.
Fasten the IDU to the rack by inserting screws into holes of 19” mechanical adaptors and by screwing them into relevant holes provided with nut cage situated on rack brackets (see Figure 71 on page 101)
![Page 105: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/105.jpg)
ED 05 3DB 06687 DAAA 105/178
5.2.3. Rack mount adapters installation in a rack
The mechanical fittings are shown in the assembly drawing of Figure 76
19” brackets
21” brackets
Figure 76 - IDU adapter for installation
![Page 106: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/106.jpg)
ED 05 3DB 06687 DAAA 106/178
5.2.4. Grounding of the subrack
The subrack must be grounded using the Faston connector present on the rear side of the apparatus, see Figure 77 on page 106 (DETAIL A). The section cable (wire) to use must be a 1X 3 mm2 (12AWG) (Yellow/Green) The subrack-mounting item , adds a good electrical connection to rack ground.
SEE DETAIL A
DETAIL A
Figure 77 - Subrack cabinets grounding points
![Page 107: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/107.jpg)
ED 05 3DB 06687 DAAA 107/178
5.3. Minimum distances between systems installed in the rack
Minimun space between 2 IDU
Space between 1+1 configuration
1+1 IDU Rack
![Page 108: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/108.jpg)
ED 05 3DB 06687 DAAA 108/178
Minimun distance between
1+1 configuration 2U A 1U B 2UA 1U B 2U A A
A
A
B
B
1+1 IDU Rack
Figure 78 - Minimum distances for dense packing in both systems (1+0 and 1+1)
Figure 79 – Summary of minimum distance in 1+0 and 1+1 configuration
![Page 109: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/109.jpg)
ED 05 3DB 06687 DAAA 109/178
5.4. Wall mounting kit description The mechanical support (kit ref. 3CC09614AAAA) can be used for wall installation and it can support a maximum of three units.
The kit includes: • Two brackets • Four fixing for the brackets
o M6x50 socket cap screws o Onduflex washers o Expension bolt
The mechanical support can contain a maximum of ONE unit in case of system 1+0 and TWO units in case of system 1+1, both equipped with mini distributor. The possible installations are the followings:
1+0 and 1+1 Installation wall with and without mini distributor
1+0 and 1+1 typical wall installation (horizontal and vertical positioning) The wooden or masonry wall that is selected for the installation should be in a suitable portion of the room. Preferably it should be near to a safety power outlet, and it should ensure safeguard against accidental tampering. It is possible to install the apparatus in a horizontal or vertical position
Detail A
The mechanical support must be grounded using the Grounding Kit 3CC13423AAAA
Figure 80 - Fixing the mechanical support to the wall
Detail A
Grounding point
![Page 110: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/110.jpg)
ED 05 3DB 06687 DAAA 110/178
6. IDU INTERCONNECTIONS
6.1. Module interconnections, description External interfaces are listed in the following figures, with corresponding connectors. The interfaces are divided into two groups, depending on their location: MAIN UNIT, and EXTENSION UNIT. The EXTENSION UNIT can be supplied only for IDU 1+1.
.
Figure 81 – Main Unit Front
Figure 82 –Extension Unit Front
![Page 111: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/111.jpg)
ED 05 3DB 06687 DAAA 111/178
6.1.1. IDU – ODU cable disconnection/connection
Before to disconnect or connect the IDU-ODU cable (at IDU or ODU side) switch off the corresponding IDU Main Unit or IDU Extension Unit.
Craft Terminal connection
To connect the CT cable (at IDU’s interface and/or PC side):
• veirfy that the PC is switched of (if switched on, close all running applications, then switch of it)
• connect suitable cable to IDU’s F interface and PC side
• now the PC can be safely switched on
Craft Terminal diconnection
To disconnect the CT cable (at IDU’s F interface and/or PC side):
• perform the logoff, exiting from the CT applications
• close all other running applications, if any
• switch off the PC
• now the cable can be safely disconnected
![Page 112: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/112.jpg)
ED 05 3DB 06687 DAAA 112/178
(1)Battery input(SubD 3 pin female)
(7)Acknowledgement(push button)
(8)Test Lamp(push button)
(9)Reset(push button)
(10)Telephone (RJ11)
(11)OS 10/100 base T(RJ45)
(12)Debug (RJ45)
(13)ECT - RS232(SubD 9 pin female)
(3)(1+1) Inter-connection(SCSI 100 pin female)
(6)NMS_V11 - AUDIO 1(SubD 15 pin female)
(16)NMS_G703-AUDIO 2(SubD 15 pin female)
(5)Alarms Housekeeping(SubD 15 pin female)
(15)User service channel(SubD 15 pin female)
Leds
(17)IDU - ODU
(Connector N female
(4)9 -16 E1/DS1 - 32 wires(SubD 37 pin female)
(4)E3/DS3(2x1.0 - 2.3 female)
(4)Ethernet user data(2xRJ45)
(2)ON-OFF Switch
(14)8 E1/DS1 - 32wires(SubD 37 pin female)
1 2 3 4 5 6
7 8 9 10 11 12 13 14 15 16 17
Figure 83 - Main Front / Rear view interconnections IDU
Flash card
Figure 84 – Main Rear view (Flash card insertion)
![Page 113: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/113.jpg)
ED 05 3DB 06687 DAAA 113/178
ESC
(1)Battery input(SubD 3 pin male)
(6)8 E1/DS1 - 32 wires (SubD 37 pin female)
I/O (1/8)
(7)User service channel(SubD 15 pin female)
LT
I O
ON ODUW
Leds
(8)IDU - ODU(Connector N female)
(4)9 -16 E1/DS1 - 32 wires(SubD 37 pin female)
(4)E3/DS3(2x1.0 - 2.3 female)
(4)Ethernet user data(2xRJ45)
(2)ON-OFFSwitch
(5)Test lamp(push button)
(3)(1+1) Inter - connection(SCSI 100 pin female)
INTER - CONNECTION
1 2 3 4
5 6 7 8
Figure 85 - Extension Front view interconnections IDU
Figure 86 - Extension Rear view IDU
![Page 114: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/114.jpg)
ED 05 3DB 06687 DAAA 114/178
Antenna
ODU
(11) OS
optional distributor subrack
Power supply(1)
(14)1-8 E1(15)User service channels
(5)Alarms - Housekeeping
to ODU(17)
NMS G.703 + Audio 2(16)
NMS V.11 + Audio 1(6)
to IDU
INTERFACES OF 8E1 IDU 1+0
(11)OS
optional distributor subrack
Power supply(1)
(14)1-8 E1 (15)User service channels
(5)Alarms - Housekeeping
to ODU(17)
NMS V.11 + Audio 1(6)
(4)9-16 E1
INTERFACES OF 16E1 IDU 1+0
(11) OS
optional distributor subrack
Power supply(1) (15)User service channels
(5)Alarms - Housekeeping
to ODU(17)
NMS V.11 + Audio 1(6)
(4) E3
INTERFACES OF E3 IDU 1+0
NMS G.703 + Audio 2(16)
NMS G.703 + Audio 2(16)
(11)OS
optional distributor subrack
Power supply(1) (15) User service channels
(5) Alarms - Housekeeping
to ODU
NMS V.11 + Audio 1
Ethernet(4)
INTERFACES OF ETHERNET + 8E1 IDU 1+0
NMS G.703 + Audio 21-8 E1(14)
Figure 87 – 1+0 Interconnections view
![Page 115: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/115.jpg)
ED 05 3DB 06687 DAAA 115/178
(11)OSPower supply(1)
(14) 1-8 E1
(15) User service channels
(5) Alarms - Housekeeping
to ODUCH 1(17)
NMS G.703 + Audio 2(16)
NMS V.11 + Audio 1(6)
to ODUCH 0
(8)
INTERFACES OF 8E1 IDU 1+1
optional distributor subrack (7) User service channels(6) 1-8 E1
(3) (1+1) Inter-connectionSCSI 100
Power supply(1)
Figure 88 – 1+1 Interconnection view (8E1)
(11) OS(14) 1-8 E1
(5)Alarms - HousekeepingNMS V.11 + Audio 1
(6)
(4) 9-16 E1 NMS G.703 + Audio 2(16)
(15) User service channels
to ODUCH 1(17)
to ODUCH 0
(8)
Power supply(1)
optional distributor subrackINTERFACES OF 16E1 IDU 1+1
Power supply(1)
(4) 9-16 E1(6) 1-8 E1 (7) User service channels
(3) (1+1) Inter-connectionSCSI 100
Figure 89 – 1+1 Interconnection view (16E1)
![Page 116: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/116.jpg)
ED 05 3DB 06687 DAAA 116/178
optional distributor subrack
INTERFACES OF E3 IDU 1+1
(11) OS (4) E3
(15) User service channels(5) Alarms - Housekeeping
to ODUCH 1(17)
NMS G.703 + Audio 2(16)
NMS V.11 + Audio 1(6)
to ODUCH 0
(8)
Power supply(1)
(3) (1+1) Inter-connectionSCSI 100
Power supply(1) (4) E3 (7) User service channels
Figure 90 – Interconnection view (E3)
to ODUCH 1(17)
NMS G.703 + Audio 2(16)
NMS V.11 + Audio 1(6)
to ODUCH 0
(8)
(15)User service channels(5)Alarms - Housekeeping
(11) OS(14) 1-8 E1(4) EthernetPower supply
(1)
INTERFACES OF Ethernet + 8E1 IDU 1+1
optional distributor subrack
(3) (1+1) Inter-connectionSCSI 100
Power supply(1) (6) 1-8 E1 (7)User service channels
Figure 91 – Interconnection view (Ethernet
NOTE: Figures in parentheses correlate to Fig. Ref. Column in Table 18, page 117 and Table 21, page 121.
The IDU is offered in two different configurations (1+0 and 1+1 configuration):
![Page 117: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/117.jpg)
ED 05 3DB 06687 DAAA 117/178
6.2. Numbering and functions referred to the Connection Points
Table 18 - Numbering and functions referred to the Connection Points (Main)
Ref
Figure 84
FROM MAIN BOARD TO Or TO
(1) Battery input T.R.U or Power Supply Battery
(4) 9-16 E1/DS1 – 32wires (Plug-in) Extension (1+1) Station Distributor
(4) E3/DS3 (Plug-in) Extension (1+1) Station Distributor
(4) Ethernet user data (Plug-in) Extension (1+1) Station Distributor
(5) Alarms Housekeeping Station Distributor
(6) NMS_V11 – AUDIO 1 Adjacent AWY N.E. Access NMS_V11- AUDIO 1 (EOW)
(10) Telephone Handset
(11) OS 10/100 base T Craft Terminal or T.M.N.
(12) Debug Only for internal use
(13) ECT – RS 232 PC - Craft Terminal
(14) 8 E1/DS1 – 32 wires Customer Distributor (CDF)
(15) User Service Channel Station Distributor
(16) NMS_G703 – AUDIO 2 Adjacent AWY N.E. Access NMS_G703 - Audio 2 (EOW)
(17) Connector N ODU
NB: (6) – (16) NMS INTERFACE AWY-MELODIE (see Figure 98 on page 130)
![Page 118: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/118.jpg)
ED 05 3DB 06687 DAAA 118/178
Table 19 - Numbering and functions referred to the Connection Points (Extension)
Ref
Figure 85
FROM EXTENSION BOARD
TO
Or
To
(1) Battery input T.R.U. Power Supply Battery
(3) 1+1 Inter-connection Main
(4) 9-16 E1/DS1 – 32wires (Plug-in) Main
(4) E3/DS3 (Plug-in) Main
(4) Ethernet user data (Plug-in) Main
(6) 8 E1/DS1 – 32 wires Main
(7) User Service Channel Main
(8) Connector N ODU
![Page 119: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/119.jpg)
ED 05 3DB 06687 DAAA 119/178
Table 20 - Numbering and functions referred to the Connection Points (1+1 version)
Ref
Figure 84
Ref Figure
85
Main Board Extension Board To or To
(1) (1) Battery input Battery input T.R.U. PSU
(3) (3) 1+1 Inter-connection Extension - 1+1 Inter-connection
(4) (4) 9-16 E1/DS1 – 32wires (Plug-in) Extension - 9-16 E1/DS1 – 32wires (Plug-in)
(4) (4) E3/DS3 (Plug-in) Extension – E3/DS3 (Plug-in)
(4) (4) Ethernet user data (Plug-in) Extension – Ethernet user data (Plug-in)
(5) Alarms Housekeeping
(6) NMS_V11 – AUDIO 1
(10) Telephone
(11) OS 10/100 base T
(12) Debug
(13) ECT – RS 232
(14) (6) 8 E1/DS1 – 32 wires Extension 8 E1/DS1 – 32 wires
(15) (7) User Service Channel Extension User Service Channel
(16) NMS_G703 – AUDIO 2
(17) (8) Connector N Connector N ODU
![Page 120: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/120.jpg)
ED 05 3DB 06687 DAAA 120/178
6.3. Summary and type connectors usage
Interface Connector Type Paragraph (1) Battery Input SubD3 Male 6.4.18 (2) ON – OFF Switch Two position
switch 6.4.19
(3) 1+1 Inter-connection SCSI 100 pin Female
(4) 9-16 E1/DS1 32 wires SubD37 Female 6.4.3 (4) E3/DS3 2x(1.0/2.3) Female 6.4.10 (4) Ethernet user data 2xRJ45 6.4.12 (5) Alarms Housekeeping SubD15 Female 6.4.9 (6) NMS_V11 – AUDIO 1 SubD15 Female 6.4.5 (7) M - Acknowledgment Push – Button 6.4.11 (8) LT - Test Lamp Push – Button 6.4.11 (9) R – Reset Push – Button 6.4.11 (10) TPH – Telephone RJ11 6.4.15 (11) OS 10/100 base T (or ECT) RJ45 6.4.12 (12) Debug RJ45 6.4.11 (13) ECT-RS232 SubD9 Female 6.4.13 (14) 8E1/DS1 – 32 wires SubD37 Female 6.4.3 (15) User Service Channel SubD15 Female 6.4.8 (16) NMS_G703 – AUDIO 2 SubD15 Female 6.4.6 (17) IDU-ODU Cable N 6.4.16
IDU Main Unit
Leds N° 6 Led 6.4.11
Only for 1+1 system Interface Connector Type Paragraph
(1) Battery Input SubD 3 Male 6.4.18 (2) ON – OFF Switch Two position
switch 6.4.19
(3) 1+1 Inter-connection SubD37 Female 6.4.3 (4) 9-16 E1/DS1 32 wires SubD37 Female 6.4.3 (4) E3/DS3 2x(1.0/2.3) Female 6.4.10 (4) Ethernet user data 2xRJ45 (5) LT - Test Lamp Push – Button 6.4.11 (6) 8E1/DS1 – 32 wires SubD37 Female 6.4.3 (7) User Service Channel SubD15 Female 6.4.8
IDU
Ex
tens
ion
Uni
t
Leds N° 2 ON/ODUW 6.4.11
NB: (6) – (16) IDU MAIN UNIT – NMS INTERFACE AWY-MELODIE (see Figure 98 on page 130)
![Page 121: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/121.jpg)
ED 05 3DB 06687 DAAA 121/178
6.4. Suggested cabling Table 21 - Suggested cabling
Cable Type Connection type Alcatel P/N
100 wire SCSI cable for 1+1 3DB06592ABXX 37 wires 8E1/DS1 cable for 1+1 (Split Cable) 3CC13659AAXX E3/DS3 cable for 1+1 Male 3DB06593AAXX User Service Channel cable for 1+1 SubD-15 Male 3DB06594AAXX
Connection cable 24 V 3X10² SubD-3 Male
3CC08212AAAA
Connection Cable 48 V (3X4²) SubD-3 Male
3CC08211AAAA
FILOTEX COAX CABLE 50 OHM 1AC001100022
CABLE 8XE1/DS1 IDU/DISTR-1.0/2.3-75 OHM UNB 1.0/2.3 Male
3DB10008AAXX
CABLE 8XE1/DS1 IDU/DISTR - 120 OHM BAL 3DB10007AAXX
CABLE 8XE1/DS1 IDU/DISTR 1.6/5.6-75 OHM UNB 2m 1.6/5.6 Male
3CC07885ABAA
CABLE 8XE1/DS1 IDU/DISTR - 120 OHM 2m 120 ohm 3CC07658AAAB CABLE 8XE1/DS1 IDU/DISTR-BNC-75 OHM UNB 2m BNC Male 75 ohm 3CC07759ABAA
HA-HC/SC cable L=15m SubD-15 Male
3DB05594AAXX
NMS/AUDIO CABLE L=1.6 m SubD-15 Male
3DB05922AAXX
NMS/AUDIO CABLE L=6.4 m SubD-15 Male
3DB05923AAXX
NMS INTERFACE AWY-MELODIE IDU L= 1.6m 3DB10063AAAA NMS INTERFACE AWY-MELODIE IDU L= 6.4 3DB10064AAAA 2MHz 75OHM cable L=1m 1AC001100013
RS232CT cable SubD-9 Female
1AB054120027
75 OHM COAX CABLE 8XE1/DS1 IDU/DISTR NO CONNECTORS L=10M
SubD-37 Male
3DB05588AAAA
Male Coax Connector 1.0/2.3 Male 1AB061220005 Male Coax Connector 1.6/5.6 Male 1AB009870002 Male Coax Connector BNC 75 ohm Male 1AB006420060 Panel Coax Connector 1.0/2.3 Female 1AB009790019 Panel Coax Connector 1.6/5.6 Female 1AB002130006 Panel Coax Connector BNC 75 ohm Female 1AB006020076
120 OHM 8x2 twisted pair cable 1AC011980001 100 OHM CABLE for 8XDS1 1AC021980001 120 OHM Cable L904/16p lg 15m w connector 3CC08951ACAA Power Supply connection 24V (3X2.52) 3CC0829AAAA Power Supply connection 48V (3X1.52) 3CC08165AAAA Ethernet crossover cable – L=2m 3DB05021AAAA Ethernet crossover cable – L=6.4 3DB14051AAAA Ethernet cable – L= 2m 3DB14046AAAA Ethernet cable – L= 6.4m 3DB14050AAAA ESC AWY connection – L=1.6m 3DB10087AAAA ESC AWY connection – L=6.4 3DB10088AAAA
![Page 122: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/122.jpg)
ED 05 3DB 06687 DAAA 122/178
6.4.1. Split Cable
SUB D 37/ 15 male
(1+0) Main Unit ExtensionUnit
User
“Special Split Cable”for E1/DS1Tributaries (37pins)
and for UserService Channels (15pins)
SUB D 37/ 15 male
SUB D 37/ 15 male
Figure 92 – E1 / DS1 and User Service Channel Split-Cable
![Page 123: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/123.jpg)
ED 05 3DB 06687 DAAA 123/178
Figure 93 – Cable connections (example)
![Page 124: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/124.jpg)
ED 05 3DB 06687 DAAA 124/178
6.4.2. Inter- connection Main – Extension flat cable
In 1+1 configuration the two subracks (Main and Extension) are inter-connected by means of auxiliary flat cable (100-wires SCSI)
Inter - connector(100 wire SCSI)
Inter – connector(100 wire SCSI)
Figure 94-1+1 Inter-connection
![Page 125: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/125.jpg)
ED 05 3DB 06687 DAAA 125/178
6.4.3. I/O 1 through 8 and I/O 9 through 16
8 E1/DS1 - 32 wires(SubD 37 pin female)
18 1
37 19
8 E1/DS1- 32 wires(SubD 37 pin female)
9-16 E1/DS1 - 32 wires (SubD 37 pin female)
18 1
37 19
I/O (9/16)
9-16 E1/DS1- 32 wires(SubD 37 pin female)
Figure 95 - I/O 1 through 8 and 9 through16 connections (Main – Extension) 16E1 – 16DS1
Two 37-pin SubD connectors allow for the connection of 16 tributaries.
For E1 tributaries the same input and output wires are reused for 120 Ω balanced and 75 Ω unbalanced (see Table 21, page 121 and Table 22, page 126).
For DS1 tributaries one impedance is foreseen (100 Ω balanced).
NOTE: to reduce the interferences phenomena one cable (8 pair twisted cable) is used to connect all TX pins (A) and other one cable (8 pair twisted cable) is used to connect all RX pins (B). See the Table 22/Table 23 on page 126. See the Table 24 – Distributor Subrack and Cable type on page 127
![Page 126: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/126.jpg)
ED 05 3DB 06687 DAAA 126/178
Table 22 - I/O (1 through 8) connections
Description Pin # Description Pin # Cable Reserved 1 Reserved 20 IN+Trib. 1 2 IN-Trib. 1 21 IN+Trib. 2 3 IN-Trib. 2 22 IN+Trib. 3 4 IN- Trib. 3 23 IN+Trib. 4 5 IN- Trib. 4 24 IN+Trib. 5 6 IN- Trib. 5 25 IN+Trib. 6 7 IN- Trib. 6 26 IN+Trib. 7 8 IN- Trib. 7 27 IN+Trib. 8 9 IN- Trib. 8 28
GND 10 Reserved 11
Reserved 29
OUT+Trib. 1 12 OUT-Trib. 1 30 OUT+Trib. 2 13 OUT-Trib. 2 31 OUT+Trib. 3 14 OUT-Trib. 3 32 OUT+Trib. 4 15 OUT-Trib. 4 33 OUT+Trib. 5 16 OUT-Trib. 5 34 OUT+Trib. 6 17 OUT-Trib. 6 35 OUT+Trib. 7 18 OUT-Trib. 7 36 OUT+Trib. 8 19 OUT-Trib. 8 37
See par. 6.4 on page 121
Table 23 - I/O (9 through 16) connection
Description Pin # Description Pin # Cable Reserved 1 Reserved 20
IN+Trib. 9 2 IN-Trib. 9 21 IN+Trib. 10 3 IN-Trib. 10 22 IN+Trib. 11 4 IN-Trib. 11 23 IN+Trib. 12 5 IN-Trib. 12 24 IN+Trib. 13 6 IN-Trib. 13 25 IN+Trib. 14 7 IN-Trib. 14 26 IN+Trib. 15 8 IN-Trib. 15 27 IN+Trib. 16 9 IN-Trib. 16 28
GND 10 Reserved 11
Reserved 29
OUT+Trib. 9 12 OUT-Trib. 9 30 OUT+Trib. 10 13 OUT-Trib. 10 31 OUT+Trib. 11 14 OUT-Trib. 11 32 OUT+Trib. 12 15 OUT-Trib. 12 33 OUT+Trib. 13 16 OUT-Trib. 13 34 OUT+Trib. 14 17 OUT-Trib. 14 35 OUT+Trib. 15 18 OUT-Trib. 15 36 OUT+Trib. 16 19 OUT-Trib. 16 37
See par. 6.4 on page 121
A (TX)
B (RX)
A (TX)
B (RX)
![Page 127: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/127.jpg)
ED 05 3DB 06687 DAAA 127/178
6.4.4. Mini Distributor connection
The user ports are implemented on two 37–way connectors: for the 2 Mbit/s tributary ports. The user must choose from the configurations listed below.
Distributor Subrack Cable type Distributor Subrack for 1.6/5.6 (3CC08061AAAA). (Cable8X1/DS1 IDU/DISTR-1.6/5.6 – 75 ohm UNB 3CC07885ABAA)
Distributor 1U Subrack for 120 ohm NO EMC (3CC08062AAAA). (Cable 8XE1/DS1 IDU/DISTR- 120 ohm 3CC07658AAAB)
Distributor 3U Subrack for 120 ohm EMC (3CC07810AAAA). (Cable 8XE1/DS1 IDU/DISTR- 120 ohm 3CC07658AAAB)
Distributor Subrack for BNC (3CC08061ABAA). (Cable8X1/DS1 IDU/DISTR-BNC – 75 ohm UNB 3CC07759ABAA)
Table 24 – Distributor Subrack and Cable type
For more information see USER MANUAL/TECHNICAL HANDBOOK 9400 AWY Rel.2.0
![Page 128: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/128.jpg)
ED 05 3DB 06687 DAAA 128/178
6.4.5. NMS V11 - AUDIO 1 (EOW)
NMS_V11 - AUDIO 1(SubD 15 pin female)
18
915
“(NMS_V11+Audio1)” interface has 9 pins dedicated to NMS and 6 pins dedicated to EOW analog party line.
NMS_V11 channel is a 64Kb/s co directional and TX and RX are totally asynchronous.
Pin # Description Cable
1 RS422 data in (+) 2 RS422 clock in (+) 3 RS422 data out (+) 4 RS422 clock out (+) 5 GND NMS 6 AUDIO 1 (EOW) signal from user (+) 7 AUDIO 1 (EOW) signal to user (+) 8 GND Audio 9 RS422 data in (-)
10 RS422 clock in (-) 11 RS422 data out (-) 12 RS422 clock out (-) 13 AUDIO 1 (EOW) signal from user (-) 14 AUDIO 1 (EOW) signal to user (-) 15 Not used
See par. 6.4 on page 121
Figure 96 - NMS V11 – Audio1 (EOW) connections
![Page 129: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/129.jpg)
ED 05 3DB 06687 DAAA 129/178
6.4.6. NMS G703 + Audio 2 (EOW)
8 1
15 9
NMS_G703 - AUDIO 2(SubD 15 pin female)
“(NMS_G703 + Audio2)” interface has 5 pins dedicated to NMS and 6 pins dedicated to EOW analog party line.
NMS_G703 channel is a 64Kb/s; its working mode can be selected between:
• DTE G703 data in and G703 data out have to be synchronous, G703 data out being the slave,
• Asynchronous: G703 data in and G703 data out are totally asynchronous.
Pin # Description Cable
1 G703 data in (+) 2 Not used 3 G703 data out (+) 4 Not used 5 GND NMS 6 AUDIO 2 (EOW) signal from user (+) 7 AUDIO 2 (EOW) signal to user (+) 8 GND Audio 9 G703 data in (-) 10 Not used 11 G703 data out (-) 12 Not used 13 AUDIO 2 (EOW) signal from user (-) 14 AUDIO 2 (EOW) signal to user (-) 15 Not used
See par. 6.4 on page 121
Figure 97 - NMS_G703 + Audio2 (EOW) connections
![Page 130: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/130.jpg)
ED 05 3DB 06687 DAAA 130/178
6.4.7. NMS INTERFACE AWY-MELODIE
8 1
15 9
NMS INTERFACE AWY-MELODIE
(SubD 15 pin female)
NOTE:
AWY SIDE: in this connection there are both signal Audio (party-line) and Supervision G703 or V11 in alternative
MELODIE SIDE: the party line connection is stand-aloneas stand-alone the NMS connector.
MELODIE – SIDE (9 PINS)
AWY IDU- SIDE (15 PINS)
3DB10063AAAA NMS INTERFACE AWY-MELODIE IDU L= 1.6m 3DB10064AAAA NMS INTERFACE AWY-MELODIE IDU L= 6.4m
AUDIO
NMS
Figure 98 – NMS INTERFACE AWY-MELODIE
![Page 131: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/131.jpg)
ED 05 3DB 06687 DAAA 131/178
6.4.8. Service Channel
User service channel external interface (SubD15) is located both 9400AWY Main and Extension board.
A special user service channel cable (linking externally the SubD15 connectors on Main and Extension subrack) is used to support EPS protection in (1+1) configuration; no wires are thus necessary to be exchanged on the auxiliary (1+1) flat cable.
8 1
15 9
User service channel(SubD 15 pin female)
User Service channel(SubD 15 pin female)
SERVICE channel provides external access for auxiliary channel by means of a 15-pin SubD 15 female connector.
Pin # Signal Meaning Direction Cable
2 COD_RX + G703_64K_RX + INPUT 9 COD_RX - G703_64K_RX - INPUT 3 COD_TX + G703_64K_TX + OUTPUT 10 COD_TX - G703_64K_TX - OUTPUT 4 RX_ASY V24/V28 asynchronous_RX INPUT 11 TX_ASY V24/V28 asynchronous_TX OUTPUT 5 CC_RX + V11_64K_DATA_RX + INPUT 12 CC_RX - V11_64K_DATA_RX - INPUT 6 RX_CK + V11_64K_CLOCK_CK + BID 13 RX_CK - V11_64K_CLOCK_CK - BID 7 CC_TX + V11_64K_DATA_TX + OUTPUT 14 CC_TX - V11_64K_DATA_TX - OUTPUT 8 CC_TCK + V11_64K_CLOCK_TCK + OUTPUT 15 CC_TCK + V11_64K_CLOCK_TCK - OUTPUT 1 GND Ground /
See par.
6.4 on page 121
Figure 99 - SERVICE CHANNEL connections (Main – Extension)
![Page 132: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/132.jpg)
ED 05 3DB 06687 DAAA 132/178
6.4.9. Housekeeping Alarms
Alarms Housekeeping(SubD 15 pin female)
18
915
The “ Housekeeping Alarms-” SubD15 connector is divided into:
3 summarizing discrete alarms – equipment outputs;
4 housekeeping controls – equipment outputs;
6 housekeeping alarms – equipment inputs;
1 common wire dedicated to equipment outputs;
1 common wire dedicated to equipment inputs.
Pin Connector Signal Direction Cable 6 M2 HK_I1 INPUT
13 M2 HK_I2 INPUT 7 M2 HK_I3 INPUT
14 M2 HK_I4 INPUT 8 M2 HK_I5 INPUT
15 M2 HK_I6 INPUT 4 M2 HK_O1 OUTPUT
11 M2 HK_O2 OUTPUT 5 M2 HK_O3 OUTPUT
12 M2 HK_O4 OUTPUT 9 M2 COM -COMMON WIRE
(FOR ALARM OUTPUTS)
1 M2 A_1 OUTPUT 2 M2 A_2 OUTPUT 3 M2 A_3 OUTPUT
10 M2 GROUND (ALARM INPUT COMMON PONIT)
/
See par. 6.4 on page 121
Figure 100 - Housekeeping- Alarms- connections
![Page 133: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/133.jpg)
ED 05 3DB 06687 DAAA 133/178
6.4.10. E3 - DS3
E3/DS3(2x1.0 - 2.3 female)
E3/DS3 (2x1.0-2.3 female)
Figure 101 - E3 DS3 Interface connections (Main – Extension)
Two 1.0 /2.3 Siemens adapter connectors are dedicated to the E3/DS3 input/output; the impedance is always 75 Ω unbalanced. The first adapter is a 100 cm cable with a 1.0/2.3 "locking" connector and a BNC connector (cod. 041.992.634), the second adapter is a 100 cm cable with a 1.0/2.3 "locking" connector and a 1.6/5.6 connector (cod. 041.992.635).
![Page 134: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/134.jpg)
ED 05 3DB 06687 DAAA 134/178
6.4.11. M, LT, LEDs (housekeeping, Summarizing)
ONRDI MIN EOW
ODUW LDI MAJ ATTD
LEDs
M - Acknowledgement (Push button)
LT - Test Lamp (Push button)
R - Reset (Push button)
ON ODUW
LEDsLT
Figure 102 - M, LT and LEDs meanings The M pushbutton turns off the LEDs alarms. The LT (lamp test) pushbutton verifies if the LEDs alarms are turn on. The following LEDs are present on the front panel of the Main and Extension Board
LED meanings
POS. LED MEANING COLOUR 1 ON Power – on Green 2 RDI Remote Defect Indication Red 3 MIN Minor alarm Red 4 EOW Engineering Order wire / RPS position Busy (Yellow), FREE (Green) / RPS on (Green) 5 ODUW ODU working Green 6 LDI Local Defect Indication Red 7 MAJ Major Alarm Red 8 ATTD Attended Yellow
![Page 135: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/135.jpg)
ED 05 3DB 06687 DAAA 135/178
6.4.12. OS – DEBUG
OS (or ECT)10/100 base T(RJ45)
Debug (RJ45)
Figure 103 – OS - DEBUG connections cable pin out table
These connections are directly made on the RJ45 connectors mounted on the main unit, and use the 10/100 base T interface.
Ethernet pin out cable
M1 RJ45
MAIN sideSignal Color used
M2 RJ45 Eth1 Eth2
M2 RJ45 CT
side
CABLE
1 Tx + White/Orange 1 3 2 Tx - Orange 2 6 3 Rx + White/Green 3 1 4 Blue 4 4 5 White/Blue 5 5 6 Rx - Green 6 2 7 White/Brown 7 7 8 Brown 8 8
See par. 6.4 on
page 121
Pins 4,5,7 and 8 are not used
CT Ethernet cable
![Page 136: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/136.jpg)
ED 05 3DB 06687 DAAA 136/178
6.4.13. CT access
ECT - RS232 (SubD 9 pin female)
15
69
In Figure 104 on page 136 is detailed the pinout for the RS 232 - 9 pins connector to interconnect the Personal Computer to the CT .
RS 232
IDU MAIN side RS 232 (PC side)
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9
Figure 104 - CT connections
6.4.14. R - Reset pushbutton
This pushbutton resets the unit software.
![Page 137: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/137.jpg)
ED 05 3DB 06687 DAAA 137/178
6.4.15. TPH – Telephone Handset
TPH - Telephone handset (RJ11)
1AF12831AAAA
RJ11 Connector
![Page 138: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/138.jpg)
ED 05 3DB 06687 DAAA 138/178
6.4.16. IDU – ODU connections
IDU - ODU (Connector N female)
IDU - ODU (Connector N female)
Figure 105 - IDU ODU interconnections (Main – Extension)
The transceiver inside the ODU module is connected to the IDU side through an IDU-ODU interconnecting 50 ohm coaxial cable (1AC001100022). The connector used is a N male connector (1AB095530021). In order to assemble the connector to the coaxial cable, refer to the leaflet enclosed into the supplied connector beg, however hereafter are reported some of the main connector assembling descriptions .
6.4.16.1. Connector N – Torque Tightening
NOTE: TORQUE Tightening Connector N 1) Connector N (Male) on the IDU 2 Nm 2) Connector N (Male) on the ODU 3 Nm 3) Connector N (Male) on the external discharger 3 Nm
6.4.16.2. Maximun length
MAX LENGHT CODE DESCRIPTION 16E1 16DS1
1AC00110022 Filotex coax cable 50 ohm 250 m 150 m
![Page 139: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/139.jpg)
ED 05 3DB 06687 DAAA 139/178
6.4.17. 50 Ohms connector assembling
NB: Hereafter we show some example of connector assembling , however each connector is delivered with it’s own description leaflet enclosed into the connector delivering plastic bag.
6.4.17.1. ROSENBERGER CONNECTOR MOUNTING Straight
50 Ohms connector assembling description
1) Strip 15 mm of outer insulation from the cable and comb out the braid.
2) Fit the nut, washer, flat gasket and braid clamp onto the cable, then fold back the braid over the braid clamp and cut away the excess. Strip the core of the cable to the dimensions opposite.
3) Fit the center contact fully home on the core of the cable. Crimp with DANIELS M225/5-01 tool fitted with jaws Y215P (hex:.128 across flats). If not possible, solder. CAUTION: DO NOT MELT THE CABLE INSULATION.
4) About the gasket and washer against the braid clamp then offer up the end of the cable into the body of the connector making sure that the contacts mate correctly with each other. Screw the nut into the body of the connector (torque: 5 Nm). The connector is now ready for use.
Figure 106 - Details for assembling “N” connector to coaxial cable
![Page 140: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/140.jpg)
ED 05 3DB 06687 DAAA 140/178
6.4.17.2. ROSENBERGER CONNECTOR MOUNTING - 90° Male
50 Ohms connector assembling description 1 Prepare the cable according to the diagram. Cut the cable’s jacket ( 12 mm + 3 mm ) 15 mm long.
2 Disassemble the connector as shown in the figure.
3 Slide nut “A”, washer “B” and gasket “C” onto the cable. Push clamp “D” over the braid and fold the braid back over the clamp.
4 Insert the prepared cable fully into the connector body “E” and position
the inner conductor of the cable in the slot of the central pin. 5 Thread nut “A” and tighten down with torque 4 Nm. 6 Solder central pin to the inner conductor of the cable. 7 Place washer “F” and tighten down cover “G” into the rear aperture of the
connector body.
NB. Coupling torque: 15N.m to 35N.m.
![Page 141: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/141.jpg)
ED 05 3DB 06687 DAAA 141/178
6.4.18. Power Supply connector, On / Off switch
Battery (1)
Battery (1)
Figure 107 – Power Supply Connector
The PSU is a plug-in of the IDU “Main/extension Board”.
It is a module including DC/DC converters and filters. It is plugged onto the main board by means of suitable connectors. Three versions exist:
1) ± 48Vdc to ± 60Vdc ±20%;
2) ± 24Vdc -20% +50%
according to the IDU MAIN UNIT and IDU EXTENSION UNIT.
![Page 142: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/142.jpg)
ED 05 3DB 06687 DAAA 142/178
SAFETY RULES
Due to possible very high currents in case of short-circuit at the battery power input; it is essential that the battery power distribution line be provided with a short circuit back-up protection with adequate breaking capacity
Max rating of branch circuit protection is 15A (USA/CANADA) or 16A (Others)
Battery Pin Function Cable A1 + BATTERY A2 GROUND A3 - BATTERY
See par. 6.4 on
page 121
Figure 108 - Power supply connections
6.4.19. ON-OFF switch
Powers the unit on and off.
ON – OFF Switch
Figure 109 – ON-OFF Switch
![Page 143: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/143.jpg)
ED 05 3DB 06687 DAAA 143/178
7. CAPACITY EXTENSION 9400 AWY R.2.0.4 can be provided with transceiver able to support 32E1 capacity even if the IDU supports 16E1 maximun. The above could be usefully in case of successive capacity extensions. If the case, pay attention to the following:
• IDU-ODU (Filotex Coax Cable 50 ohm) With Filotex coax cable there limitation in the maximum length (150m instead of 250m for ETSI version); a more performant cable could be necessary to cover specific cases
• IDU installation in Rack To migrate from 16E1 to 32E1 the IDU must be substituited with other subracks that can require more room (see related documentation) For an easy successive extension the eventual additional room needed should be left free.
![Page 144: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/144.jpg)
ED 05 3DB 06687 DAAA 144/178
ANNEXES W.T.D. Rack installation Mechanical installation
Installation has been sub–divided into the following phases:
- Rack Positioning and Fastening
- Fixing the rack to floor using expansion bolts or Fixing to floating floor;
- T.R.U. fastening to W.T.D rack. Rack Positioning and Fastening
Proceed as follows:
- Refer to the plant documentation to see rack row assignment
- Fasten the rack to the station structure according to one of the following procedures:
- Fixing the rack to floor (see paragraph 2.2.3)
- Fixing the rack to floating floor (see paragraph 2.2.4) Fixing the rack to floor using expansion bolts
(See Figure 110 on page 145)
- Mount the rack in a vertical position in the desired place.
- Mark the base–plate with six holes (1) to be drilled on the floor
- Temporarily remove the rack and drill the holes at the points drawn on the floor (see Figure 111 on page 146).
- Place the inserts into the holes
- Secure the expander bolts to the floor through the base–plate holes.
![Page 145: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/145.jpg)
ED 05 3DB 06687 DAAA 145/178
20
12**
NOTES:
All dimensions are in millimetres
** Diameter drill
* Fixable max thickness
EXPANSION ANCHOR M8x40
1
Figure 110 - Fixing the W.T.D. rack using expansion anchors
![Page 146: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/146.jpg)
ED 05 3DB 06687 DAAA 146/178
142 mm30 mm
30 mm
98 mm
300 mm149 mm 149 mm
DRILL HOLES
Figure 111 - rack - Drill Holes for Anchoring to the Floor (single rack)
![Page 147: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/147.jpg)
ED 05 3DB 06687 DAAA 147/178
Fixing to floating floor
The drilling mask is the same used for concrete floor fastening (
Figure 111 on page 146). In this case a hole must be created for the cables coming from the bottom according to Figure 112 on page 147. The rack fastening is to be mounted on the concrete floor below using a suitable stud as shown in
Figure 113 on page 148.
Using the row layout drawing, mark out the cable entry areas in the floor tiles and cut out with a jigsaw. Remember that the beginning of the row must be approved by the customer.
N.B. Unused or incompletely used cable entry areas should be blocked off with foam rubber.
96.25
149
81
598
130
61.25
106
149 300
35
35
30
30
80
297.25
CABLE ENTRYAREA
FIBER DUCTS
26
Figure 112 - rack - Floor tile drilling template
![Page 148: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/148.jpg)
ED 05 3DB 06687 DAAA 148/178
HEX NUT
LOCKWASHER
FLAT WASHER
STUD
BOTTOM
EXPANSION PLUG
LOCKWASHER
FLAT WASHER
HEX NUTComputer Floor
Concrete Floor
Rack base
HEX NUT
LOCKWASHER
FLAT WASHER
STUD
Figure 113 - rack - Example of securing rack assembly to computer floor
![Page 149: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/149.jpg)
ED 05 3DB 06687 DAAA 149/178
T.R.U. fastening to the W.T.D rack
SAFETY RULES
T.R.U. fastening to the rack guarantees the connection to the protection ground in that the rack is wired to the station protection ground.
See Figure 114on page 149.
Fix the T.R.U. (1) to the rack by inserting screws (2) into the holes of the adapter (4), screw them into the relative holes on side-wall (3).
1
32
4
Figure 114 - rack - T.R.U. fastening to the rack
Figure 115 - W.T.D rack - Front plate 6 circuit breakers Electrical connections
Electrical Installation has been sub–divided into the following phases:
- Protection ground Connections
![Page 150: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/150.jpg)
ED 05 3DB 06687 DAAA 150/178
- Power supply connection
Protection ground Connections The rack must be grounded by means of a connection to the protection ground terminal of the site electrical plant.
SAFETY RULES
The rack must be connected to the protection ground before performing any other
electrical connection.
In Figure 116 on page 149 is shown the connection of the ground on the topside of the rack.
The rack is grounded to the station through a 16 to 25 mm2 (1 to 2 AWG) section cable (1) terminated onto the cable terminal lug (2).
12
Figure 116 - Rack - Ground connections
![Page 151: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/151.jpg)
ED 05 3DB 06687 DAAA 151/178
AWY supply voltage & Grounding section cables
System AWY 1+0 AWY 1+1
Cables length Up to 20 m Up to 20 m
BB Unipolar cable section Power Supply
BB Unipolar cable section Grounding Cable
2 x 1.5 mm2 shielded
1 x 3 mm2
2 x 1.5 mm2 shielded
1 x 3 mm2
TRU Unipolar cable section Power Supply
TRU 16 circuit breakers full equipped with AWY sys.
Grounding Cable section
TRU Unipolar cable section Grounding Cable
RACK Unipolar cable section Grounding Cable
2 x 16 mm2
1 X > =16 mm2
1 X > =16 mm2
2 x 16 mm2
1 X > =16 mm2
1 X > =16 mm2
NB: For WTD rack the TRU doesn’t require any cable ground connection to the rack.
![Page 152: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/152.jpg)
ED 05 3DB 06687 DAAA 152/178
Annex A CABLE CODE INTERCONNECTIONS DESCRIPTION
DESCRIPTION N° CODE
Type M1 n° pin
M2 n° pin
M3 n° pin
Lenght
1 3DB05021AAAA RJ45 8 8 2m 2 3DB05922AA** Sub-D 15 15 1,6m 3 3DB05923AA** Sub-D 15 15 6,4m 4 3DB10063AAAA Sub-D 15 9 9 1,6m 5 3DB10064AAAA Sub-D 15 9 9 6,4m 6 3DB10087AAAA Sub-D 15 15 1,6m 7 3DB10088AAAA Sub-D 15 15 6,4m 8 3DB10089AAAA Sub-D 15 9 9 3DB10090AAAA Sub-D 15 9 10 3DB10091AAAA Sub-D 15 25 1,6m 11 3DB10092AAAA Sub-D 15 25 6,4m 12 3DB10093AAAA Sub-D 15 9 1,6m 13 3DB10094AAAA Sub-D 15 9 6,4m 14 3DB10095AAAA Sub-D 15 15 15 3DB10096AAAA Sub-D 15 15 16 3DB10100AAAA Sub-D 37 9 9 17 3DB10101AAAA Sub-D 15 15 18 3DB14051AAAA RJ45 8 8 6,4m 19 3CC52119AAAA Sub-D 15 9 9 1,6m 20 3CC52120AAAA Sub-D 15 9 9 6,4m 21 3CC52121AAAA Sub-D 37 9 25 1m 22 3CC52130AAAA Sub-D 15 9 1,6m 23 3CC52131AAAA Sub-D 15 9 6,4m 24 3CC52132AAAA Sub-D 15 9 1m
Annex B - Table 1 – Cable code interconnections
![Page 153: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/153.jpg)
ED 05 3DB 06687 DAAA 153/178
Cable 3DB05922AAAA (L.= 1.6m) or 3DB05923AAAA (L.=6,4m)
CONNECTION CABLE M1 Pair colours Pair number M2 1 Blue 3 9 Withe 1 11 2 Violet 4
10 Turquoise 2 12 3 Orange 1
11 Withe 3 9 4 Violet 2
12 Turquoise 4 10 5 Green 5
To cut Withe 5 To cut 6 Violet 7
13 Turquoise 6 14 7 Brown 6
14 Withe 7 13 8 Violet 8
To cut Turquoise 8 To cut
Annex B - Table 2 – Connections Cable 3DB05922AAAA (L.= 1.6m) or 3DB05923AAAA (L.=6,4m)
Sub-D 15pins Male
Sub-D 15pins Male M1 M2
![Page 154: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/154.jpg)
ED 05 3DB 06687 DAAA 154/178
Cable 3DB05021AAAA (L.= 2m) or 3DB14051AAAA (L.=6,4m)
CONNECTION CABLE Pair Wire A M1
Pin N° M2
Pin N° Wire B M1
Pin N° M2
Pin N° 1 White/Blue ring 1 3 Blue 2 6 2 White/Orange ring 3 1 Orange 6 2 3 White/Green ring 4 4 Green 5 5 4 White/Brown ring 7 7 Brown 8 8
Annex B - Table 3 – Connecton Cable 3DB05021AAAA (L.= 2m) or 3DB14051AAAA (L.=6,4m)
RJ45 8pins
M2 M1
RJ45 8pins
![Page 155: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/155.jpg)
ED 05 3DB 06687 DAAA 155/178
Cable 3DB10095AAAA (L.= 1.6m) or 3DB10096AAAA (L.=6,4m)
CONNECTION CABLE M1 Pair colours Pair number M2/M1 2 Blue M2-11 9 Withe 1 M2-3 4 Orange M2-9
11 Withe 2 M2-1 6 Green M2-10
13 Withe 3 M2-2 3 Brown M1-5
10 Withe 4 M1-12 5 Grey M1-3
12 Withe 5 M1-10 1 Blue M2-5
To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
Annex B - Table 4 – Connection Cable 3DB10095AAAA (L.= 1.6m) or 3DB10096AAAA (L.=6,4m)
M2 M1
Sub-D 15pins Male
Sub-D 15pins Male
![Page 156: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/156.jpg)
ED 05 3DB 06687 DAAA 156/178
Cable 3DB10087AAAA (L.= 1.6m) or 3DB10088AAAA (L.=6,4m) –
ANNEX B - Figure 1 - Back to back cord connection ESC - AWY
CONNECTION CABLE M1 Pair colours Pair number M2 2 Blue 3 9 Withe 1 10 3 Violet 2
10 Turquoise 2 9 4 Orange 11 1 Withe 3 1 5 Violet 7
12 Turquoise 4 14 6 Green 8
13 Withe 5 15 7 Violet 5
14 Turquoise 6 12 8 Brown 6
15 Withe 7 13 11 Violet 4
To cut Turquoise 8 To cut
Annex B - Table 5 – Connection Cable 3DB10087AAAA (L.= 1.6m) or 3DB10088AAAA (L.=6,4m)
Sub-D 15pins Male
Sub-D 15pins Male M1 M2
![Page 157: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/157.jpg)
ED 05 3DB 06687 DAAA 157/178
Cable 3DB10089AAAA (L.= 1.6m) or 3DB10090AAAA (L.=6,4m)
CONNECTION CABLE M1 Pair colours Pair number M2 7 Blue 1
14 Withe 1 6 8 Orange 7
15 Withe 2 2 5 Green 8
12 Withe 3 4 6 Brown 9
13 Withe 4 5 1 Grey 3
To cut Withe 5 To cut To cut Blue To cut To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
Annex B - Table 6 – Connection Cable 3DB10089AAAA (L.= 1.6m) or 3DB10090AAAA (L.=6,4m)
M1 M2
Sub-D 15pins Male Sub-D 9pins Male
![Page 158: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/158.jpg)
ED 05 3DB 06687 DAAA 158/178
Cable 3DB10091AAAA (L.= 1.6m) or 3DB10092AAAA (L.=6,4m)
CONNECTION CABLE
M1 Pair colours Pair number M2 5 Blue 13
12 Withe 1 25 6 Orange 12
13 Withe 2 24 7 Green 11
14 Withe 3 23 8 Brown 22
15 Withe 4 10 To cut Grey To cut To cut Withe 5 To cut To cut Blue To cut To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
Annex B - Table 7 – Connection Cable 3DB10091AAAA (L.= 1.6m) or 3DB10092AAAA (L.=6,4m)
M1 M2 Sub-D 25pins Male
Sub-D 15pins Male
![Page 159: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/159.jpg)
ED 05 3DB 06687 DAAA 159/178
Cable 3DB10100AAAA (L.= 1m)
CONNECTION CABLE (M1-M2) M1 (37pins) Pair colours Pair number M2 (9pins)
1 Blue 1 20 Withe 1 6 2 Orange 2
21 Withe 2 7 4 Green 8
23 Withe 3 4 5 Brown 9
24 Withe 4 5 18 Grey 3
To cut Withe 5 To cut To cut Blue To cut To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
CONNECTION CABLE (M1-M3) M1 (37pins) Pair colours Pair number M3 (9pins)
7 Blue 1 26 Withe 1 6 8 Orange 2
27 Withe 2 7 10 Green 8 29 Withe 3 4 11 Brown 9 30 Withe 4 5 18 Grey 3
To cut Withe 5 To cut To cut Blue To cut To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
CONNECTION CABLE (M1-M4) M1 (37pins) Pair colours Pair number M4 (9pins)
13 Blue 1 32 Withe 1 6
M1
M2
M3
M4
Sub-D 37pins Male
Sub-D 9pins
Female
Sub-D 9pins
Female
Sub-D 9pins
Female
![Page 160: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/160.jpg)
ED 05 3DB 06687 DAAA 160/178
14 Orange 2 33 Withe 2 7 15 Green 8 34 Withe 3 4 16 Brown 9 35 Withe 4 5 18 Grey 3
To cut Withe 5 To cut To cut Blue To cut To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
Annex B - Table 8 – Connection Cable 3DB10100AAAA (L.= 1m)
![Page 161: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/161.jpg)
ED 05 3DB 06687 DAAA 161/178
Cable 3DB10101AAAA (Adapter ESC/NMS V1)
CONNECTION CABLE
M1 M2
5 1 12 9 6 2 13 10 7 3 14 11 8 12 15 4 1 5
![Page 162: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/162.jpg)
ED 05 3DB 06687 DAAA 162/178
Cable 3CC52119AAAA (L.= 1,6) or 3CC52120AAAA (L.=6,4)
ANNEX B - Figure 2 – NMS ESC ¾ CROSSED CABLE
CONNECTION CABLE (M1-M2-M3) M1
(15pins) M2 (NMS)
(9pins) M3 (AUDIO)
(9pins) Pair colours Pair number
1 8 Blue 9 4 Withe 1
3 1 Violet 11 6 Turquoise 2
2 5 Orange 10 9 Withe 3
4 7 Violet 12 2 Turquoise 4
5 to connect to shielded cable braid (GND) Green To cut Withe 5
6 8 Violet 13 4 Turquoise 6
7 1 Brown 14 6 Withe 7
To cut Violet To cut Turquoise 8
Annex B - Table 9 – Connection Cable 3CC52119AAAA (L.= 1,6) or 3CC52120AAAA (L.=6,4)
M1
M3
M2
Sub-D 9pins Male
Sub-D 15pins Male
Sub-D 9pins Male
![Page 163: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/163.jpg)
ED 05 3DB 06687 DAAA 163/178
Cable 3CC52121AAAA (L.= 1m)
ANNEX B - Figure 3 – LUX 50 ESC-ESC / ALARMS ADAPTER
CONNECTION CABLE (M1-M2-M3) M1 (37pins) M2 (9pins) M3 (25pins) Pair number
1 8 20 4 1
2 9 21 5 2
4 1 23 6 3
5 2 24 7 4
11 No connect 3 11 6 12 5
22 no connect 13 no connect 25 no connect 24 no connect
7 7 26 20 6
8 8 27 21 7
9 9 28 22 8
10 10 29 23 9
14 1 15 2 10
32 14 33 15 11
34 16 16 3 12
17 4 18 5 13
35 17 36 18 14
37 19 19 6 15
12 3 30 25 16
Annex B - Table 10 – Connection - Cable 3CC52121AAAA (L.= 1m
M2
M3
M1
Sub-D 37pins Male
Sub-D 25pins Female
Sub-D 9pins Female
![Page 164: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/164.jpg)
ED 05 3DB 06687 DAAA 164/178
Cable 3DB10063AAAA (L.= 1,6)
ANNEX B - Figure 4 – NMS INTERFACE AWY – MELODIE IDU
CONNECTION CABLE (M1-M2-M3) M1
(15pins) M2 (NMS)
(9pins) M3 (AUDIO)
(9pins) Pair colours Pair number
1 8 Blue 9 4 Withe 1
3 1 Violet 11 6 Turquoise 2
10 5 Orange 10 9 Withe 3
4 2 Violet 12 7 Turquoise 4
5 to connect to shielded cable braid (GND) Green To cut Withe 5
6 8 Violet 13 4 Turquoise 6
7 1 Brown 14 6 Withe 7
To cut Violet To cut Turquoise 8
Annex B - Table 11 – Connection Cable 3DB10063AAAA (L.= 1,6)
M3
M2
M1
Sub-D 15pins Male
Sub-D 9pins Male
Sub-D 9pins Male
![Page 165: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/165.jpg)
ED 05 3DB 06687 DAAA 165/178
Cable 3DB10093AAAA (L.= 1.6m)
CONNECTION CABLE
M1 Pair colours Pair number M2 7 Blue 6
14 Withe 1 1 8 Orange 7
15 Withe 2 2 5 Green 4
12 Withe 3 8 6 Brown 5
13 Withe 4 9 1 Grey 3
To cut Withe 5 To cut To cut Blue To cut To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
Annex B - Table 12 – Connection Cable 3DB10093AAAA (L.= 1.6m)
M2 M1
Sub-D 9pins Male
Sub-D 15pins Male
![Page 166: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/166.jpg)
ED 05 3DB 06687 DAAA 166/178
A.1. Cable 3CC52130AAAA (L.= 1.6m) or 3CC52131AAAA (L.= 6.4m)
CONNECTION CABLE
M1 Pair colours Pair number M2 7 Blue 1
14 Withe 1 6 8 Orange 2
15 Withe 2 7 5 Green 8
12 Withe 3 4 6 Brown 9
13 Withe 4 5 1 Grey 3
To cut Withe 5 To cut To cut Blue To cut To cut Red 6 To cut To cut Orange To cut To cut Red 7 To cut To cut Green To cut To cut Red 8 To cut
Annex B - Table 13 – Connection Cable 3DB52130AAAA (L.= 1.6m)
M2 M1
Sub-D 9pins Male
Sub-D 15pins Male
![Page 167: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/167.jpg)
ED 05 3DB 06687 DAAA 167/178
Annex B NETWORK INTERCONNECTIONS AWY-AWY Interconnections Cable list B.1.1. NMS Continuity
Code Type Cable From Equipment To Equipment 3DB05922AA** Sub.D 15 pins (IDU) NMS_V11
Audio1 (IDU) NMS_V11 Audio1
3DB05923AA** Sub.D 15 pins (IDU) NMS_V11 Audio1
(IDU) NMS_V11 Audio1
3DB05922AA** Sub.D 15 pins (IDU) NMS_G703 Audio2
(IDU) NMS_G703 Audio2
3DB05923AA** Sub.D 15 pins (IDU) NMS_G703 Audio2
(IDU) NMS_G703 Audio2
3DB05021AAAA RJ45 8 pins (IDU) NMS Ethernet IP DCN 3DB14051AAAA RJ45 8 pins (IDU) NMS Ethernet IP DCN 3DB10101AAAA Sub.D 15 pins Adapter Adapter 3DB10095AAAA Sub.D 15 pins (IDU) NMS_V11
Audio1 IP Router (IP DCN)
3DB10096AAAA Sub.D 15 pins (IDU) NMS_V11 Audio1
IP Router (IP DCN)
Annex C - Figure 1 – NMS Continuty
Annex C - Figure 2 – NMS Continuity
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
OD U OD U
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_V11 Audio1
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_G703 Audio2
3DB05922AA**or
3DB05923AA**
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
NMS_V11 Audio1
IP DCN
NMS Eth
Station B
GNE
Management through microwave link
Management through microwave link
Management through microwave link
Station A
NMS_G703 Audio2
Station C
Station D
3DB05021AAAA or
3DB14051AAAA
3DB05922AA**or
3DB05923AA**
3DB10095AAAA or
3DB10096AAAA
IP DCN
IP ROUTER IP ROUTER OD
U OD U
64kbps
Station C
RS T
ON / OFF
AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_V11 Audio 1
3DB05922AA**or
3DB05923AA**
IDU
ODU
IDU
ODU
IDU
ODU
NMS_V11 Audio 1 NMS_V11 Audio 1
RS485 / V11 64kbps
Station B
GNE OSPF Area n
OSPF Area n Management through microwave link
Management through microwave link
Station A
Cisco cable X21-FC
![Page 168: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/168.jpg)
ED 05 3DB 06687 DAAA 168/178
Annex C - Figure 3 - NMS Continuity on ESC
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_V11
IDU
ODU
NMS Eth
OD U OD U
IP DCN
GNE
Management through microwave link
3DB05021AAAAor
3DB14051AAAA
3DB10101AAAA+
3DB05922AA**
ESC NMS_V11
3DB10101AAAA +
3DB05922AA**
ESC
![Page 169: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/169.jpg)
ED 05 3DB 06687 DAAA 169/178
AUDIO Connection
Code Type Cable From Equipment To Equipment 3DB05922AA** Sub.D 15 pins (IDU) NMS_G703 Audio2 (IDU) NMS_G703 Audio2 3DB05923AA** Sub.D 15 pins (IDU) NMS_G703 Audio2 (IDU) NMS_G703 Audio2 3DB05922AA** Sub.D 15 pins (IDU) NMS_V11 Audio1 (IDU) NMS_V11 Audio1 3DB05923AA** Sub.D 15 pins (IDU) NMS_V11 Audio1 (IDU) NMS_V11 Audio1
Annex C - Figure 4 – AUDIO Connection
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_G703 Audio2
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_V11 Audio1
3DB05922AA** or
3DB05923AA**
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
NMS_G703 Audio2
Station B
Station A
NMS_V11 Audio1
Station C
Station D
3DB05922AA**or
3DB05923AA**
![Page 170: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/170.jpg)
ED 05 3DB 06687 DAAA 170/178
NMS Ring Protection with Audio Continuity
Code Type Cable From Equipment To Equipment 3DB05922AA** Sub.D 15 pins (IDU) NMS_V11 Audio1 (IDU) NMS_V11 Audio1 3DB05923AA** Sub.D 15 pins (IDU) NMS_V11 Audio1 (IDU) NMS_V11 Audio1 3DB05922AA** Sub.D 15 pins (IDU) NMS_G703 Audio2 (IDU) NMS_G703 Audio2 3DB05923AA** Sub.D 15 pins (IDU) NMS_G703 Audio2 (IDU) NMS_G703 Audio2 3DB05021AAAA RJ45 8 pins (IDU) NMS Ethernet (IDU) NMS Ethernet 3DB14051AAAA RJ45 8 pins (IDU) NMS Ethernet (IDU) NMS Ethernet
Annex C - Figure 5 – NMS Ring protection with audio continuity
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS _G703 Audio2
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS _V11 Audio1
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
NMS _G703 Audio2
Station B
Station A
NMS _V11 Audio1
Station C
Station D
3DB05021AAAA or
3DB14051AAAA Ethernet
3DB05922AA**or
3DB05923AA**
3DB05922AA** or
3DB05923AA**
![Page 171: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/171.jpg)
ED 05 3DB 06687 DAAA 171/178
ESC Continuity
Code Type Cable From Equipment To Equipment 3DB10087AAAA Sub.D 15 pins (IDU) ESC (IDU) ESC 3DB10088AAAA Sub.D 15 pins (IDU) ESC (IDU) ESC
Annex C - Figure 6 – ESC Continuity
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3DB10087AAAA or 3DB10088AAAA
IDU
ODU
IDU
ODU
ESC
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
ESC
IDU
ODU
![Page 172: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/172.jpg)
ED 05 3DB 06687 DAAA 172/178
B.2. AWY-MELODIE SNMP Interconnections Cable list NMS Continuity with Audio Connection
Code Type Cable From Equipment To Equipment 3DB05922AA** Sub D 15 (IDU) NMS_G703
Audio2 (IDU) NMS_G703 Audio2
3DB05923AA** Sub D 15 (IDU) NMS_G703 Audio2
(IDU) NMS_G703 Audio2
3DB10063AAAA Y cable sub D 15 – (2x Sub D 9) AWY (IDU) NMS_V11 Audio1
Melodie (IDU) NMS_V11 and Audio1
3DB10064AAAA Y cable sub D 15 – (2x Sub D 9) AWY (IDU) NMS_V11 Audio1
Melodie (IDU) NMS_V11 and Audio1
3DB05021AAAA RJ45 8 pins (IDU) NMS Ethernet IP DCN 3DB14051AAAA RJ45 8 pins (IDU) NMS Ethernet IP DCN
Annex C - Figure 7 – NMS continuity with Audio connection
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_G703 Audio2
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS_V11 Audio1
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
IDU
ODU
NMS_G703 Audio2
NMS Eth
OD U OD U
IP DCN Station B
GNE
Management through microwave link
Management through microwave link
Management through microwave link
Station A
NMS1
3DB10063AA**or
3DB10064AA**
Station C
Station D
3DB05021AAAA or
3DB14051AAAA
3DB05922AA**or
3DB05923AA**
Audio1
Melodie
![Page 173: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/173.jpg)
ED 05 3DB 06687 DAAA 173/178
Service Channel Continuity (MELODIE 1+0 classic)
Code Type Cable From Equipment To Equipment 3DB10089AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) ESC3-4 3DB10090AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) ESC3-4 3DB10100AAAA Adapter Sub D 37 – (3x Sub D 9)
Annex C - Figure 8 – Service Channel continuity (MELODIE 1+0 classic) Service Channel Continuity (MELODIE 1+0 Light)
Code Type Cable From Equipment
To Equipment
3CC52130AAAA Sub D 15-Sub D 9 AWY (IDU) ESC Y cable Sub D 9 ESC3 3CC52131AAAA Sub D 15-Sub D 9 AWY (IDU) ESC Y cable Sub D 9 ESC3 3DB10121AAAA Y cable sub D 37 – (Sub D 9 + Sub D 25) Melodie
ESC3/Alarm
Annex C - Figure 9 – Service Channel continuity – (MELODIE 1+0 Light)
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3DB10089AAAAor
3DB10090AAAA
IDU
ODU
IDU
ODU
ESC
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
ESC 3-4
IDU
ODU
3DB10100AAAA
Melodie 1+0 Classic
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3CC52130AAAAor
3CC52131AAAA
IDU
ODU
IDU
ODU
ESC
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
ESC 3
IDU
ODU
3CC52121AAAA
Melodie 1+0 Light
Alarm
![Page 174: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/174.jpg)
ED 05 3DB 06687 DAAA 174/178
Service Channel Continuity (MELODIE 1+1)
Code Type Cable From Equipment To Equipment 3DB10091AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) ESC5 3DB10092AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) ESC5
Annex C - Figure 10 – Service Channel continuity (MELODIE 1+1) Service Channel Continuity (MELODIE 1+1)
Code Type Cable From Equipment To Equipment 3DB10089AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) ESC3-4 3DB10090AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) ESC3-4
Annex C - Figure 11 - Service Channel continuity (MELODIE 1+1)
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3DB10091AAAA or 3DB10092AAAA
IDU
ODU
IDU
ODU
ESC
Melodie 1+1
ODU ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L
URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
ESC 5
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
IDU
ODU
ESC
3DB10089AAAA or 3DB10090AAAA
Melodie 1+1
ODU ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L
URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L
URG ATT IDU NURG ODU
ESC EXT EX T
OD
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
ESC 3-4
![Page 175: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/175.jpg)
ED 05 3DB 06687 DAAA 175/178
AWY-MELODIE RQ2 Interconnections Cable list AWY NMS_V11 Transport (MELODIE 1+0 Classic)
Code Type Cable From Equipment To Equipment 3DB10063AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio 1 (IDU) ESC3-4-5 3DB10064AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio 1 (IDU) ESC3-4-5 3DB10100AAAA Adapter Sub D 37 – (3x Sub D 9)
Annex C - Figure 12 – AWY NMS V11 Transport (MELODIE 1+0 classic) AWY NMS_V11 Transport (MELODIE 1+0 Light)
Code Type Cable From Equipment To Equipment 3CC52119AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio
1 (IDU) ESC5
3CC52120AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio 1
(IDU) ESC5
3CC52121AAAA Y cable sub D 37 – (Sub D 9 + Sub D 25)
Annex C - Figure 13 - AWY NMS V11 Transport (MELODIE 1+0 light)
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3DB10063AAAAor
3DB10064AAAA
IDU
ODU
IDU
ODU
NMS_V11 Audio1
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
ESC 3
IDU
ODU
3DB10100AAAA
Melodie 1+0 Classic
ESC 4
ESC 5
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3CC52119AAAAor
3CC52120AAAA
IDU
ODU
IDU
ODU
NMS_V11 Audio1
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
ESC 3
IDU
ODU
3CC52121AAAA
Melodie 1+0 Light
![Page 176: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/176.jpg)
ED 05 3DB 06687 DAAA 176/178
AWY NMS_V11 Transport (MELODIE 1+1)
Code Type Cable From Equipment To Equipment 3DB10063AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio 1 (IDU) ESC3-4 3DB10064AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio 1 (IDU) ESC3-4
Annex C - Figure 14 - AWY NMS V11 Transport (MELODIE 1+1) AWY NMS_V11 Transport (MELODIE 1+1)
Code Type Cable From Equipment To Equipment 3DB10063AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio 1 (IDU) ESC5 3DB10064AAAA Y cable sub D 15 – (2x Sub D 9) (IDU) NMS_V11 Audio 1 (IDU) ESC5 3CC52132AAAA Sub D 25 – Sub D 9 (IDU) NMS_V11 Audio 1
Annex C - Figure 15 - AWY NMS V11 Transport (MELODIE 1+1)
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3DB10063AAAA or 3DB10064AAAA
IDU
ODU
IDU
ODU
NMS_V11 Audio1
Melodie 1+1
ODU ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L
URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L
URG ATT IDU NURG ODU
ESC EXT EX T
OD
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
ESC 5
3CC52132AAAA
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3DB10063AAAA or 3DB10064AAAA
IDU
ODU
IDU
ODU
NMS_V11 Audio1
Melodie 1+1
ODU ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L
URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L
URG ATT IDU NURG ODU
ESC EXT EX T
OD
Main IDU
ESC EXT
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
Ext. IDU ESC MAIN
ESC 3-4
![Page 177: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/177.jpg)
ED 05 3DB 06687 DAAA 177/178
RQ2 9.6 K/b Transport
Code Type Cable From Equipment To Equipment 3DB10093AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) NMS1 3DB10094AAAA Sub D 15 – Sub D 9 (IDU) ESC (IDU) NMS1
Annex C - Figure 16 – RQ2 9.6 K/b Transport
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
3DB10093AAAA or 3DB10094AAAA
IDU
ODU
IDU
ODU
ESC
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
IDU
ODU
RS T
ON OFF AC O I/
O 4W 1 4W 2
ESC EXT NM
S 1 NM S 2 EX
T F
DEB UG I/
O A L C T E L URG ATT IDU NURG ODU
ESC EXT EX T
OD U
NMS1
IDU
ODU
Melodie
![Page 178: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/178.jpg)
ED 05 3DB 06687 DAAA 178/178
END OF DOCUMENT
![Page 179: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/179.jpg)
All
right
s re
serv
ed. P
assi
ng o
n an
d co
pyin
g of
this
docu
men
t, us
e an
d co
mm
unic
atio
n of
its
cont
ents
not p
erm
itted
with
out w
ritte
n au
thor
izat
ion
from
Alc
atel
.
3DB 06687 DAAA TQZZA Ed.05 1 / 4
QUESTA PAGINA NON VA INSERITA NEL MANUALETHIS PAGE MUST NOT BE INCLUDED IN THE HANDBOOK
COD.MANUALE HDBK P/N: 3DB 06687 DAAA Ed.059400AWY Rel.2.0INSTALLATION HANDBOOK
ISTRUZIONI PER LA STAMPA ED ASSIEMAGGIO DI QUESTO MANUALEINSTRUCTIONS FOR PRINT AND ASSEMBLY OF THIS MANUAL
– COMPOSIZIONE ED ASSIEMAGGIO DEL MANUALE:HANDBOOK COMPOSITION AND ASSEMBLY:
– STAMPARE FRONTE/RETRO RECTO-VERSO PRINTING
fasestep
No pagine(facciate)
numeratenumbered
step (facciate)No pages da from a to
1
TARGHETTE - LABELS
N.B. se il manuale viene termorilegato senzacartelletta, le targhette non servono. Comecopertina, utilizzare il frontespizio del manuale(pagina 1), stampato su cartoncino.
N.B. if handbook is thermo–bound without binder,labels are not necessary. As book–cover, use themanual front (page 1).
2 INSTALLATION HANDBOOK 178 1/178 178/178
TOTALE PAGINE A4 (FACCIATE) TOTAL A4 PAGES: 178
TOTALE FOGLI A4 TOTAL A4 SHEETS: 89
![Page 180: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/180.jpg)
All
right
s re
serv
ed. P
assi
ng o
n an
d co
pyin
g of
this
docu
men
t, us
e an
d co
mm
unic
atio
n of
its
cont
ents
not p
erm
itted
with
out w
ritte
n au
thor
izat
ion
from
Alc
atel
.
3DB 06687 DAAA TQZZA Ed.052 / 4
QUESTA PAGINA NON VA INSERITA NEL MANUALETHIS PAGE MUST NOT BE INCLUDED IN THE HANDBOOK
PUBLISHING NOTES
• Labels are done according to A-Italy binder format.
• Source files and printable files of this handbook are archived in PDM:
– Source file:
SOURCE FORMAT SIZE KbytesPDM ARCHIVE
METHODTOTAL N.PAGES
MSWORD2000 135.037 ⇒ WINZIP 178+ 4 = 182
N.B. the cat_IDU file contains the source interleaf file for this assembly document (itcan be opened by Quicksilver 1.5.3 in PC–WINDOWS environment or byInterleaf 6 in Unix environment).
– Printable file: PDF file must be opened with ACROBAT Reader Version 5.0 at least.(N.B. : it has been created with ACROBAT DISTILLER 7.0)
3DB 06687 DAAATQZZAEd.059400AWY Rel.2.0
7–8–13–15–18–23–25–28–38 GHzshort–haul low/medium capacity digital microwave radio linksINSTALLATION HANDBOOK
![Page 181: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/181.jpg)
All
right
s re
serv
ed. P
assi
ng o
n an
d co
pyin
g of
this
docu
men
t, us
e an
d co
mm
unic
atio
n of
its
cont
ents
not p
erm
itted
with
out w
ritte
n au
thor
izat
ion
from
Alc
atel
.
3DB 06687 DAAA TQZZA Ed.05 3 / 4
9400AWY Rel.2.0
7–8–13–15–18–23–25–28–38 GHz
short–haul low/medium capacity digital microwave radio links
INSTALLATION HANDBOOK
3DB 06687 DAAA Ed.05
VOL.1/1
9400AWY Rel.2.0
7–8–13–15–18–23–25–28–38 GHzshort–haul low/medium capacity digital microwave radio links
INSTALLATION HANDBOOK
3DB 06687 DAAA Ed.05
VOL.1/1
9400AWY Rel.2.07–8–13–15–18–23–25–28–38 GHz
short–haul low/medium capacity digital microwave radio links
3DB 06687 DAAA Ed.05 INSTALLATION HANDBOOK VOL.1/1
9400AWY Rel.2.07–8–13–15–18–23–25–28–38 GHz short–haul low/medium capacity digital microwave radio links
3DB 06687 DAAA Ed.05 INSTALLATION HANDBOOK VOL.1/1
9400AWY Rel.2.0
7–8–13–15–18–23–25–28–38 GHzshort–haul low/medium capacity digital microwave radio links
3DB 06687 DAAA Ed.05 INSTALLATION HANDBOOK VOL.1/1
![Page 182: Installation.pdf](https://reader037.vdocuments.mx/reader037/viewer/2022102516/563db82b550346aa9a912b97/html5/thumbnails/182.jpg)
All
right
s re
serv
ed. P
assi
ng o
n an
d co
pyin
g of
this
docu
men
t, us
e an
d co
mm
unic
atio
n of
its
cont
ents
not p
erm
itted
with
out w
ritte
n au
thor
izat
ion
from
Alc
atel
.
3DB 06687 DAAA TQZZA Ed.054 / 4
END OF DOCUMENT – FINE DEL DOCUMENTO INTERNO