PAMv2 PlusAutomatic Distillation testing+ Optical Dry Point Detectionby Orbis BV

Page 2: Innovation in distillation

About Optical Dry Point DetectionPAMv2 Plus Optical Dry Point Detection is the result of extensive research and development by Orbis BV specialists. Higher accuracy and better repeatability are obtained because of the sensor’s sensitivity and fixed position below the flask.As with existing dry point probes used in automatic distillation units, the optical dp sensor measures the temperature of the flask and detects a quick increase of heat when all liquid is evaporated. The sudden increase of heat indicates the occurence of dry point, at which point the corresponding vapor temperature is reported.

Problems with conventional dry point probes:• difficult to ensure probe positioning at the exact

bottom-center of the flask• probes are fragile and prone to breaking• inaccurate detection and bad repeatability due to

wrong probe positioning or probe insensitivity• higher operating costs higher investment

PAMv2 Plus Optical Dry Point Detection: User friendlyMaintenance freeAccurate and preciseMethod conformingFREE OF CHARGE (Standard included in PAMv2 Plus,which list price is equal to that of PAMv2)

NOTE: Conventional dry point sensor probe is still available for PAMv2 Plus.

NO FRAGILE DP PROBESLOWER INITIAL COST

LOWER OPERATING COSTACCURATE & PRECISE

Optical Dry Point Detection:

User friendly

Maintenance free

Accurate and precise

FREE OF CHARGEStandard included in PAMv2 Plus, which

list price is equal to the PAMv2 list price

Plus upgrade kit available for existing PAMv2 units

Page 3: Innovation in distillation

About Optical Dry Point DetectionPAMv2 Plus Optical Dry Point Detection is the result of extensive research and development by Orbis BV specialists. Higher accuracy and better repeatability are obtained because of the sensor’s sensitivity and fixed position below the flask.As with existing dry point probes used in automatic distillation units, the optical dp sensor measures the temperature of the flask and detects a quick increase of heat when all liquid is evaporated. The sudden increase of heat indicates the occurence of dry point, at which point the corresponding vapor temperature is reported.

Problems with conventional dry point probes:• difficult to ensure probe positioning at the exact

bottom-center of the flask• probes are fragile and prone to breaking• inaccurate detection and bad repeatability due to

wrong probe positioning or probe insensitivity• higher operating costs higher investment

PAMv2 PlusOptical Dry Point Detection: User friendlyMaintenance freeAccurate and preciseMethod conformingFREE OF CHARGE (Standard included in PAMv2 Plus, which list price is equal to that of PAMv2)

NOTE: Conventional dry point sensor probe is still available for PAMv2 Plus.

Software Application on iPadThe DistPad app for iPad functions as interface: it sends commands to - and receives test data from the instrument. The test runs independently on PAMv2’s internal microprocessor, and is not depedent on the (in)stability of a computer’s operation system.

Methods ASTM D86, D1078, D850, E123, IP195, DIN51751, ISO 3405, GOST 2177.User interface iPad with DistPad app software.Heating system Low mass/low voltage heater. Fast cooling when test is finished. Automatic shut-off in case of fire.Initial heat Auto-InHeat for first time/unknown samples. Smart program optimization for second time/future tests.Final heat Automatic & customizable.Condenser system Peltier cooled: no fluids, valves or moving parts involved. Fast cooling interactions.Temp. range 0 – 65 °C. Resolution 0.1°C.Volume detection Smart CCD camera for accurate volume measurement detects actual bottom of meniscus.

Resolution: 0.01 ml, accuracy: 0.01 ml, charge volume: 0- 103%. Automatic calibration on calibrated ring marks on receiver glass.Receiving chamber Peltier cooled: no fluids, valves or moving parts involved. Temp. range: 0 – 45 °C. Resolution 0.1°C.Residue Automatic or manual measurement.

Vapor temperature measurement

0 – 450 °C ASTM, 0 – 500 °C Absolute. PT-100 class A probe, automatic probe ID detection, calibration certificate standard supplied. True dynamic simulation of Mercury in-glass thermometer behavior (lag and stem correction).

Dry point measurement Optical Dry Point detection. Conventional dry point sensor probe available if desired.Pressure Automatic atmospheric pressure correction of test results.

System calibration against built-in pressure sensor. Range: 70 to 110 kPa, resolution 0,1 kPa.Safety UV sensor for fire detection. Built-in fire extinguisher requires nitrogen or CO2 supply from lab (connection hose is supplied).System health Automatic and fast system health check before every distillation run to ensure all components are in excellent state.Connectivity 1 x ethernet for connection to LIMS, Windows PC, FTP server, Kiosk printer and/or connection between multiple PAMV2 units.Dimensions Dimensions: 40cm x 40cm x 65cm (WxDxH), weight: 40 kg

Accessories Zebra printer

Voltage 100-240 VAC 50/60 Hz

Power 1200 W

Operating requirements Environment temperature 10 °C – 35 °C. Environment humidity up to 80 % at 35 °C.

PAMv2 Plus quick overview- Performance:Accurate & repeatable IBP/FBP/DP detection.Fast, on-the-fly heater control to maintain 4-5ml/m rate even with difficult samples.- Reliability:No fluids and almost no moving parts areused in PAMv2. This ensures reliablity and lowmaintenance on the entire instrument and thecondenser unit in particular.- Software:Depending on access rights, users either getbasic functions (“choose program/press start”)or access to all customization options. Test dataare available in PDF & XML. Windows/LIMSconnection is possible.- Safety:Flame detector, fire extinghuisher and auto-shutdown in case of fire.

Technical specifications: The app and its updates are always free

Page 4: Innovation in distillation

Ordering information:912000 - PAMv2 Plus Automatic Distillation Unit

919103 - Kiosk printer

919000 - Starter set ASTM D86 (includes all accessoires to set up PAMv2 Plus to test according ASTM D86)

919062 - Starter set ASTM D86 / D1078 / D850 (as 919000, with additional 200ml flask & 200ml centering device, 25mm & 38mm plate)

919059 - 2 Years spares and consumables ASTM D86

919060 - 2 Years spares and consumables ASTM D86 / D1078 / D850

919065 - Optical Dry Point Upgrade Kit for existing PAMv2 distillation units

GET A QUOTE OR A LIVE DEMONSTRATION CONTACT [email protected]

Innovation in distillation

About Orbis BV:Our expertise in analyzers for testing physical properties of petroleum products originated in the 1970’s. ORBIS BV was founded in 1999.

Contact:Lazar Scientific, Inc.12692 Sandy Drive, Suite 116Granger, IN [email protected]

www.lazarsci.comm

AirSTAR CFPP & CPPPFeatures:• ColdBlock: AirSTAR’s integrated cooling unit (cools down to -105ºC)

• CFPP & CP/PP Heads: easy & modular use (and investment)

• Completely according to traditional test methods

OTHER AVAILABLE PRODUCTS

AirProbe D86Features:• Digital thermometer for Manual Distillation testing• Bluetooth connection to free iOS app• All benefits of a digital vs mercury probe, yet with true mercury

lag time & stem correction• Available from fall 2017