iljin telecommunication cables

Upload: niginp

Post on 07-Jul-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/18/2019 ILJIN Telecommunication Cables

    1/20

    Application

    - ETL Verified for guaranteed performance

    - Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia

    - All accepted design for global commercial network installation

    - Simplified Structured cabling solution preserving long-term network investment- Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - 52/155 Mb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2

    - ANSI/TIA 862 (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class D)- ICEA S-90-661 (Category 5e)

    - NEC/CEC Type CM/CMR

    (UL 1685/1666)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    - KS C 3342

    UTP Category 5e

    Cross Section

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 538@100MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0(2.54)

    PackagingType 305m(1000ft) Reelex

    Weight lb/kft(kg/km) 6(9)

    Materials

    Conductors 24 AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.035(0.90), HDPE

    Jacket in.(mm) 0.19(4.83), PVC or LSZH (Low Smoke Zero Halogen)

    Technical Data

    Frequency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRFPropaga-

    tion DelayPropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    ns/100m(Max.)

    ns/100m(Max.)

    1 20.0 2.0 65.3 62.3 63.8 60.8 570 45

    4 23.0 4.1 56.3 53.3 51.8 48.8 552 45

    8 24.5 5.8 51.8 48.8 45.7 42.7 547 45

    10 25.0 6.5 50.3 47.3 43.8 40.8 545 45

    16 25.0 8.2 47.2 44.2 39.7 36.7 543 45

    20 25.0 9.3 45.8 42.8 37.8 34.8 542 45

    25 24.3 10.4 44.3 41.3 35.8 32.8 541 45

    31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45

    62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45

    100 20.1 22.0 35.3 32.3 23.8 20.8 538 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    UTP CATEGORY 5E

     

    1

    2

    3

    4

    1. Conductor

    2. Insulation

    3.Twisted Pair

    4. Ripcord (Optional)

    5. Jacket

    5

  • 8/18/2019 ILJIN Telecommunication Cables

    2/20

    Application

    - ETL Verified for guaranteed performance

    - Capable of handling full broadband and baseband video signals

    - All accepted design for global commercial network installation

    - Simplified Structured cabling solution preserving long-term network investment- Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - ANSI/TIA/EIA 854: 1000 BASE-TX

    - 155 Mb/s, 1.2 Gb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Digital Video

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2- ANSI/TIA 862

    (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class E)

    - ICEA S-102-7000 (Category 6)

    - NEC/CEC Type CM/CMR

    (UL 1685/1666)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    - KS C 3342

    UTP Category 6

    Fre-

    quency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay

    PropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Max.)

    1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45

    4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45

    8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45

    10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45

    16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45

    20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45

    25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45

    31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45

    62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45

    100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45

    250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    UTP CATEGORY 6

    Cross Section

    1

    2

    4

    5

    3

    1. Conductor

    2. Insulation

    3. Twisted Pair

    4. Cross Filler

    5. Ripcord (Optional)

    6. Jacket

    6

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0(2.54)

    PackagingType 305m(1000ft) Reelex / Reel in the box

    Weight lb/kft(kg/km) 21(32) / 27(42) (In case of 24AWG)

    Materials

    Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.037(0.95) / 0.040(1.02), HDPE

    Jacket in.(mm) 0.228(5.8) / 0.243(6.2), PVC or LSZH(Low Smoke Zero Halogen)

    Technical Data

     

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    3/20

    Application

    - Foil shield reduced electromagnetic interference (EMI) for optimal performance

    - ETL Verified for guaranteed performance

    - Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia

    - All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment

    - Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - 52/155 Mb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2

    - ANSI/TIA 862 (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class D)

    - ICEA S-90-661 (Category 5e)- NEC/CEC Type CM/CMR

    (UL 1685/1666)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    - KS C 3342

    FTP Category 5e

    Frequency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRFPropaga-

    tion DelayPropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    ns/100m(Max.)

    ns/100m(Max.)

    1 20.0 2.0 65.3 62.3 63.8 60.8 570 45

    4 23.0 4.1 56.3 53.3 51.8 48.8 552 45

    8 24.5 5.8 51.8 48.8 45.7 42.7 547 45

    10 25.0 6.5 50.3 47.3 43.8 40.8 545 45

    16 25.0 8.2 47.2 44.2 39.7 36.7 543 45

    20 25.0 9.3 45.8 42.8 37.8 34.8 542 45

    25 24.3 10.4 44.3 41.3 35.8 32.8 541 45

    31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45

    62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45

    100 20.1 22.0 35.3 32.3 23.8 20.8 538 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    FTP CATEGORY 5E

    Cross Section

    1

    2

    3

    4

    5

    6

    1. Conductor

    2. Insulation

    3. Twisted Pair

    4. Polyester Tape (Optional)

    5. Drain Wire

    6. Al/Mylar Tape7. Jacket

    7

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 538@100MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0(2.54)

    PackagingType 305m(1000ft) Reel / Reel in a Box

    Weight lb/kft(kg/km) 30(46)

    Materials

    Conductors 24 AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.043(1.08), HDPE

    Jacket in.(mm) 0.248(6.3), PVC or LSZH(Low Smoke Zero Halogen)

    Technical Data

     

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    4/20

    Application

    - Foil shield reduced electromagnetic interference (EMI) for optimal performance

    - ETL Verified for guaranteed performance

    - Capable of handling full broadband and baseband video signals

    - All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment

    - Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - ANSI/TIA/EIA 854: 1000 BASE-TX

    - 155 Mb/s, 1.2 Gb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Digital Video

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2

    - ANSI/TIA 862 (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class E)

    - ICEA S-102-7000 (Category 6)

    - NEC/CEC Type CM/CMR

    (UL 1685/1666)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    - KS C 3342

    FTP Category 6

    Fre-

    quency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay

    PropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Max.)

    1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45

    4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45

    8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45

    10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45

    16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45

    20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45

    25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45

    31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45

    62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45

    100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45

    200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45

    250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    FTP CATEGORY 6

    Cross Section

    1

    2

    3

    4

    5

    6

    7

    1. Conductor

    2. Insulation

    3. Twisted Pair

    4. Cross Filler

    5. Polyester Tape (Optional)

    6. Drain Wire

    7. Al/Mylar Tape

    8. Jacket

    8

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0 (2.54)

    PackagingType 305m(1000ft) Reel

    Weight lb/kft(kg/km) 36 (54) (In case of 24AWG)

    Materials

    Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.043(1.10) / 0.048(1.2), HDPE

    Jacket in.(mm) 0.287 (7.3) / 0.311 (7.9), PVC or LSZH (Low Smoke Zero Halogen)

    Technical Data

     

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    5/20

    Application

    - Braid & Foil shield reduced electromagnetic interference (EMI) for optimal performance

    - ETL Verified for guaranteed performance

    - Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia

    - All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment

    - Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - 52/155 Mb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2

    - ANSI/TIA 862 (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class D)- ICEA S-90-661 (Category 5e)

    - NEC/CEC Type CM/CMR

      (UL 1685/1666)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    S/FTP Category 5e

    Frequency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRFPropaga-

    tion DelayPropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    ns/100m(Max.)

    ns/100m(Max.)

    1 20.0 2.0 65.3 62.3 63.8 60.8 570 45

    4 23.0 4.1 56.3 53.3 51.8 48.8 552 45

    8 24.5 5.8 51.8 48.8 45.7 42.7 547 45

    10 25.0 6.5 50.3 47.3 43.8 40.8 545 45

    16 25.0 8.2 47.2 44.2 39.7 36.7 543 45

    20 25.0 9.3 45.8 42.8 37.8 34.8 542 45

    25 24.3 10.4 44.3 41.3 35.8 32.8 541 45

    31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45

    62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45100 20.1 22.0 35.3 32.3 23.8 20.8 538 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    S/FTP CATEGORY 5E

    Cross Section

    1

    2

    3

    4

    6

    5

    7

    1. Conductor

    2. Insulation

    3. Twisted Pair

    4. Polyester Tape (Optional)

    5. Al/Mylar Tape6. Drain Wire

    7. Tined Copper Braid

    8. Jacket

    8

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15

    Propagation Delay ns/100m 538@100MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0(2.54)

    PackagingType 305m(1000ft) Reel

    Weight lb/kft(kg/km) 38(57)

    Materials

    Conductors 24 AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.043(1.08), HDPE

    Jacket in.(mm) 0.248(6.3), PVC or LSZH (Low Smoke Zero Halogen)

    Technical Data

     

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    6/20

    Application

    - Braid & Foil shield reduced electromagnetic interference (EMI) for optimal performance

    - ETL Verified for guaranteed performance

    - Capable of handling full broadband and baseband video signals

    - All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment

    - Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - ANSI/TIA/EIA 854: 1000 BASE-TX

    - 155 Mb/s, 1.2 Gb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Digital Video

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2- ANSI/TIA 862 (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class E)

    - ICEA S-102-7000 (Category 6)

    - NEC/CEC Type CM/CMR

    (UL 1685/1666)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    - KS C 3342

    S/FTP Category 6

    Fre-

    quency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay

    PropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Max.)

    1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45

    4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45

    8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45

    10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45

    16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45

    20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45

    25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45

    31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45

    62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45

    100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45

    250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    S/FTP CATEGORY 6

    Cross Section

    1

    2

    3

    5

    4

    7

    6

    8

    1. Conductor

    2. Insulation

    3. Twisted Pair

    4. Cross Filler

    5. Polyester Tape (Optional)6. Al/Mylar Tape

    7. Drain Wire

    8. Tined Copper Braid

    9. Jacket9

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0 (2.54)

    PackagingType 305m(1000ft) Reel

    Weight lb/kft(kg/km) 45 (68) (In case of 24AWG)

    Materials

    Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.044(1.12) / 0.049(1.25), HDPE

    Jacket in.(mm) 00.311 (7.9) / 0.318 (8.1), PVC or LSZH (Low Smoke Zero Halogen)

    Technical Data

     

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    7/20

    Application

    - Protects against environmental elements that can cause electrical performance failures

    - ETL Verified for guaranteed performance

    - Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia

    - All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment

    - Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - 52/155 Mb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2

    - ANSI/TIA 862 (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class D)- ICEA S-90-661 (Category 5e)

    - ICEA S-90-661 (Category 5e)

    - NEC/CEC Type CM (UL 1685)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    - KS C 3342

    UTP Category 5e (Outdoor)

    Frequency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRFPropaga-

    tion DelayPropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    ns/100m(Max.)

    ns/100m(Max.)

    1 20.0 2.0 65.3 62.3 63.8 60.8 570 45

    4 23.0 4.1 56.3 53.3 51.8 48.8 552 45

    8 24.5 5.8 51.8 48.8 45.7 42.7 547 45

    10 25.0 6.5 50.3 47.3 43.8 40.8 545 45

    16 25.0 8.2 47.2 44.2 39.7 36.7 543 45

    20 25.0 9.3 45.8 42.8 37.8 34.8 542 45

    25 24.3 10.4 44.3 41.3 35.8 32.8 541 45

    31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45

    62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45100 20.1 22.0 35.3 32.3 23.8 20.8 538 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    UTP CATEGORY 5E OUTDOOR

    Cross Section

    1. Self Supporting Part

    2. Conductor

    3. Insulation

    4. Twisted Pair5. Rip Cord(Optional)

    6. Jacket

    Type A Type B

    4

    5

    2

    3

    1

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15

    Propagation Delay ns/100m 538@100MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0(2.54)

    PackagingType 305m(1000ft) Reelex/Reel

    Weight lb/kft(kg/km) 17(25)

    Materials

    Conductors 24 AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.035(0.90), HDPE

    Jacket in.(mm) 0.189(4.8), PVC or LSZH (Low Smoke Zero Halogen)

    Technical Data

     

    2 3

    4

    5

    6   6

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    8/20

    Application

    - Protects against environmental elements that can cause electrical performance failures

    - ETL Verified for guaranteed performance

    - Capable of handling full broadband and baseband video signals

    - All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment

    - Electrical performance comply with ANSI/TIA-568-C.2

    - Every master reel is tested for electrical performance compliance

    - RoHS Compliant

    Description: 

    - IEEE 802.3: 1000 BASE-T

    (Gigabit Ethernet),

    100 BASE-TX, 10 BASE-T

    - ANSI/TIA/EIA 854: 1000 BASE-TX

    - 155 Mb/s, 1.2 Gb/s ATM

    - ANSI X3.263: 100 Mb/s

    - IEEE 802.3af for DTE Power (PoE)

    - IEEE 802.3at for PoE Plus

    - Digital Video

    - Broadband & Baseband

    Analog Video

    Standard Compliances : 

    - ANSI/TIA 568-C.2- ANSI/TIA 862 (Building Automation)

    - ISO/IEC 11801 Ed. 2.0 (Class E)

    - ICEA S-102-7000 (Category 6)

    - NEC/CEC Type CM (UL1685)

    - RoHS Compliant Directive

    2002/95/EC

    - UL 444

    - KS C 3342

    UTP Category 6 (Outdoor)

    Fre-

    quency

    [MHz]

    ReturnLoss

    InsertionLoss

    NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay

    PropagationDelay Skew

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Min.)

    dB/100m(Max.)

    dB/100m(Max.)

    1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45

    4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45

    8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45

    10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45

    16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45

    20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45

    25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45

    31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45

    62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45

    100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45

    250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45

    Electrical Performance (ANSI/TIA-568-C.2)

    ILJIN ELECTRIC LOCAL AREA NETWORK CABLE

    UTP CATEGORY 6 OUTDOOR

    Cross Section

    1. Self Supporting Part

    2. Conductor

    3. Insulation

    4. Twisted Pair

    5. Cross Filler

    6. Rip Cord(Optional)

    7. Jacket

    6

    3  54

    2

    Type A Type B

    1

    Item Unit PVC/LSZH

    Number of Pairs EA 4

    Conductor DC Resistance Ohms/100m 9.38

    Resistance Unbalance % 5

    Mutual Capacitance nF/100m 5.6

    Capacitance Unbalance pF/100m 330

    Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz

    Delay Skew ns 45

    Nominal Velocity of Propagation % 67

    TemperatureRating

    Installation   ℃ 0 to +60

    Operation   ℃ -20 to +75

    Minimum Bend Radius in.(mm) 1.0(2.54)

    PackagingType 305m(1000ft) Reelex/Reel

    Weight lb/kft(kg/km) 27(42) (In case of 24AWG)

    Materials

    Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper

    Insulation in.(mm) 0.037(0.95) / 0.040(1.02), HDPE

    Jacket in.(mm) 0.228(5.8) / 0.243(6.2), UV-and Abrasion-Resistant PVC

    Technical Data

     

    7   7

    6

    4

    2

    53

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    9/20

    Construction

    - Conductor: Annealed plain copper solid conductor

    - Insulation: Solid polyethylene

    - Cable Element: Two insulated conductors uniformly twisted together to form a pair

    - Cable Assembly: Pairs are assembled together in concentric layers

    - Filling Compound: Water resistant filling compound applied to the air space within the cable core

    - Core Wrapping: Non-hygroscopic tape applied over the cable assembly

    - Inner Sheath: Polyethylene

    - Shield : Double Copper tape

    - Intermediate Sheath: Medium Density Polyethylene

    - Armouring: Double helically applied steel tapes

    - Outer Sheath: Polyethylene or flame retardant PVC complied with IEC 60332 part1

    Description: 

    Pilot cables are used for control,

    protection, signaling, telecommu-

    nications and data transmission

    purposes associated with power

    distribution and transmission

    systems.

    Such systems are mainly operated

    by the electrical supply industry

    and similar applications occur in

    many industrial systems.

    Pilot cables are insulated with

    special materials which are

    designed to protect them from

    the danger of induced voltages

    coming from other cable circuitsin close proximity (for example,

    faults in high voltage power cable

    circuits).

    An over voltage in the pilot cable

    cores may compromise alarm

    systems, prevent the proper op-

    eration of protection equipment,

    resulting in severe damage to the

    power system.

    Pilot Cable

    Item Unit Value

    Maximum average DC resistance of conductor /km 10.5

    Maximum mutual capacitance nF/km 54

    Maximum pair-to-pair capacitance unbalance pF/500m 275

    Propagation constant phase shift (beta) radians at 1 kHz rad/km Approx. 0.061

    Attenuation constant (alpha) dB at 1 kHz dB/km Approx. 0.52

    Real/imaginary part of impedance at 1 kHz /km Approx. 3.3 / 54.4

    Modulus of impedance at 1kHz Approx. 0.36

    Number of Pairs Conductor Size [mm2] Average Outer Diameter [mm] Net Weight [Kg/km]

    10 1.5 40 2300

    Electrical Characteristics at 20℃

    Physical Characteristics

    ILJIN ELECTRIC SIGNAL CABLE

    PILOT CABLE

    Cross Section

    5

    6

    7

    8

    9

    10

    11

    1  2   3

      4 1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Filling Compound

    6. Core Wrapping

    7. Inner Sheath

    8. Shield

    9. Intermediate Sheath

    10. Armouring11. Outer Sheath

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Signal Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application

    - Electric power distribution/transmission system

  • 8/18/2019 ILJIN Telecommunication Cables

    10/20

    Application

    Construction

    - Electric power distribution/transmission system

    - Conductor: Annealed plain copper solid conductor

    - Insulation: Solid polyethylene

    - Cable Element: Two insulated conductors uniformly twisted together to form a pair

    - Cable Assembly: Pairs are assembled together in concentric layers (with binder tape (Optional))

    - Filling Compound: Water resistant filling compound applied to the air space within the cable core

    - Core Wrapping: Non-hygroscopic tape applied over the cable assembly

    - Inner Sheath: Polyethylene

    - Shield: Double copper tape

    - Lead Alloy Sheath: Lead alloy sheath

    - Armouring: Double helically applied steel tapes

    - Outer Sheath: Polyethylene or flame retardant PVC complied with IEC 60332 part1

    Description: 

    Supervisory/Telephone cables

    are used for control, protection,

    signaling, telecommunications

    and data transmission purposes

    associated with power distribution

    and transmission systems.

    Such systems are mainly operated

    by the electrical supply industry

    and similar applications occur in

    many industrial systems.

    Supervisory / Telephone cables

    are insulated with special materi-

    als which are designed to protect

    them from the danger of induced

    voltages coming from other cablecircuits in close proximity (for

    example, faults in high voltage

    power cable circuits).

    An over voltage in the Supervi-

    sory/Telephone cable cores may

    compromise alarm systems,

    prevent the proper operation of

    protection equipment, resulting

    in severe damage to the power

    system.

    Supervisory/Telephone Cable

    Item Unit Value

    Maximum average DC resistance of conductor /km 10.5

    Maximum mutual capacitance nF/km 54

    Maximum pair-to-pair capacitance unbalance pF/500m 275

    Propagation constant phase shift (beta) radians at 1 kHz rad/km Approx. 0.061

    Attenuation constant (alpha) dB at 1 kHz dB/km Approx. 0.52

    Real/imaginary part of impedance at 1 kHz /km Approx. 3.3 / 54.4

    Modulus of impedance at 1kHz Approx. 0.36

    Number of Pairs Conductor Size [mm2] Average Outer Diameter [mm] Net Weight [Kg/km]

    20 1.5 57 6800

    Electrical Characteristics at 20℃

    Physical Characteristics

    ILJIN ELECTRIC SIGNAL CABLE

    SUPERVISORY/TELEPHONE CABLE

    Cross Section

    5

    6

    7

    8

    9

    10

    11

    1  2   3

      4 1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Filling Compound

    6. Core Wrapping

    7. Inner Sheath

    8. Shield

    9. Lead Alloy Sheath

    10. Armouring11. Outer Sheath

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Signal Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

  • 8/18/2019 ILJIN Telecommunication Cables

    11/20

    Construction

    - Conductor: Annealed plain copper solid conductor

    - Insulation: Solid polyethylene

    - Cabling Element: Four insulated conductors uniformly twisted together to form a quad

    - Cable Assembly: Quads are helically stranded to get the cable core

    - Core Wrapping: Non-hygroscopic tape applied over the cable assembly

    - Inner Sheath: Polyethylene

    - Shield: Corrugated copper tape

    - Intermediate Sheath: Polyethylene

    - Armouring: Double helically applied steel tape

    - Outer Sheath: Polyethylene or flame retardant PVC complied with IEC 60332 part1

    Description: 

    The cables are designed for con-

    nection between traffic control

    centers and equipment shelters

    along the trackside.

    The cables are specially designed

    to give good induction protection.

    (R.F=0.2 at inductive voltage

    100V/km) and are suitable for

    installation in high speed railway

    lines electrified at 25kV AC.

    ZCO3 (Railway Control & Signaling Cable)

    Number of Quad Conductor Size [mm2] Insulated Core [mm] Average Outer Diameter [mm] Net Weight [Kg/km]

    4 1 2.3 28.0 1,463

    Physical Characteristics

    frequency R (mΩ/m) L ( H/m) G (nS/m) C (pF/m)

    2040 Hz 35.424±4% 0.8157±4% < 10 < 40

    2400 Hz 35.469±4% 0.8124±4% < 10 < 40

    2760 Hz 35.509±4% 0.8097±4% < 11 < 40

    3120 Hz 35.558±4% 0.8074±4% < 11 < 40

    62.5 kHz 54.33±4% 0.747±4% < 580 < 40

    125 kHz 75.35±4% 0.7225±4% < 1248 < 40

    Item Unit Value

    Conductor resistance Ω/km 18.1

    Insulation resistance  MΩ∙km ≥5000

    Voltage strength (Conductor to Conductor)(DC voltage 3min.) kV 4.5

    Inductive voltage(V/km, at 60Hz) 50 70 100 370 400 470

    Reduction coefficient 0.42 0.30 0.20 0.16 0.18 0.31

    Electrical Characteristics at 20℃

    Reduction Coefficient

    Line Constant

    ILJIN ELECTRIC SIGNAL CABLE

    ZC03 RAILWAY CONTROL & SIGNALING CABLE

    Cross Section

    5

    6

    7

    8

    9

    10

    1  2   3

      4

    1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Core Wrapping

    6. Inner Sheath

    7. Shield

    8. Intermediate Sheath

    9. Armouring

    10. Outer Sheath

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Railway Control & Signaling Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Standard Compliances: 

    - SNCF CT 445

    - NF F 55-698 

    Application

    - Automatic Train Control (ATC) system

    - Used for signaling circuits in railway networks

    - Connects the signaling equipment centre to the track-side equipment

  • 8/18/2019 ILJIN Telecommunication Cables

    12/20

    * 2P cables assembly : star quad.

    Construction

    - Conductor: Annealed plain copper solid conductor

    - Insulation: Solid polyethylene

    - Cable Element: Two insulated conductors are uniformly twisted together to form a pair

    - Core Assembly: Pairs are helically stranded to form the cable core

    - Core Wrapping: Non-hygroscopic tape applied over the cable assembly

    - Inner Sheath: Polyethylene

    -  Intermediate Sheath: Polyethylene

    - Armouring: Double helically applied steel tape

    - Outer Sheath: General PVC or flame retardant PVC complied with IEC 60332 part1 (Halogen-Free optional)

    Description: 

    The cables are designed for con-

    nection between traffic control

    centers and equipment shelters

    along the trackside. The cables

    are specially designed to give

    good induction protection and are

    suitable for installation in high

    speed railway lines electrified at

    25kV AC.

    Standard Compliances: 

    - SNCF CT 445

    - NF C 32070 Category C2 /IEC 60332-1-2

    - NF C 32070 Category C1 /

    IEC 60332-3-24 (optional)

     

    ZPFU (Railway Control & Signaling Cable)

    Item Unit Value

    Conductor resistance /km 18.1

    Insulation resistance M∙km ≥5000

    Voltage strength (Conductor to Conductor)(DC voltage 3min.) kV 4.5

    Mutual capacitance (Pair to Pair) nF/km ≤55

    Number of Pairs Conductor Size [mm2] Insulated Core [mm] Average Outer Diameter [mm] Net Weight [Kg/km]

    2 1 2.3 15.1 441

    4 1 2.3 19.3 652

    7 1 2.3 23.0 951

    14 1 2.3 28.0 1,364

    21 1 2.3 32.3 1,750

    28 1 2.3 36.0 2,116

    Electrical Characteristics at 20℃

    Physical Characteristics

    ILJIN ELECTRIC SIGNAL CABLE

    ZPFU RAILWAY CONTROL & SIGNALING CABLE

    Cross Section

    5

    6

    7

    8

    9

    1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Core Wrapping

    6. Inner Sheath

    7. Intermediate Sheath

    8. Armouring

    9. Outer Sheath

    1  2   3 4

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Railway Control & Signaling Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application

    - Used for signaling circuits in railway networks

    - Connects the signaling equipment centre to the track-side equipment

  • 8/18/2019 ILJIN Telecommunication Cables

    13/20

    * Optional version ZPAU 2p x 1 mm2  , 2P x 1.5 mm2  and 1P X 5 mm2  are available for specific networks.

    Construction

    - Conductor: Annealed plain copper solid conductor

    - Insulation: Solid polyethylene

    - Cable Element: Two insulated conductors are uniformly twisted to form a pair

    - Core Assembly: Pairs are helically stranded to form the cable core

    - Core Wrapping: Non-hygroscopic tape applied over the cable assembly

    - Inner Sheath: Polyethylene

    - Shield: Corrugated copper tape

    - Intermediate Sheath: Polyethylene

    - Armouring: Double helically applied steel tape

    - Outer Sheath: General PVC or flame retardant PVC complied with IEC 60332 part1 (Halogen-Free optional)

    Description: 

    The cables are designed for

    connection between traffic

    control centers and equipment

    shelters along the trackside. The

    cables are specially designed to

    give good induction protection

    (R.C=0.26 at inductive voltage

    100V/km) and are suitable for

    installation in high speed railway

    lines electrified at 25kV AC.

    Standard Compliances: 

    - SNCF CT 445

    - NF F 55-698- NF C 32070 Category C2 /

    IEC 60332-1-2

    - NF C 32070 Category C1 /

    IEC 60332-3-24 (optional)

     

    ZPAU (Railway Control & Signaling Cable)

    Item Unit Value

    Conductor resistance /km 18.1

    Insulation resistance M∙km ≥5000

    Voltage strength (Conductor to Conductor)(DC voltage 3min.) kV 4.5

    Mutual capacitance (Pair to Pair) nF/km ≤55

    Number of Pairs Conductor Size [mm2] Insulated Core [mm] Average Outer Diameter [mm] Net Weight [Kg/km]

    4 1 2.3 22.8 1,028

    7 1 2.3 25.7 1,268

    14 1 2.3 30.7 1,730

    21 1 2.3 35.0 2,161

    28 1 2.3 38.7 2,562

    Electrical Characteristics at 20℃

    Physical Characteristics

    Inductive voltage (V/km, at 60Hz) 28 32 37 42 47 54 70 80 100 120 170 225

    Reduction coefficient 0.75 0.70 0.60 0.50 0.40 0.35 0.30 0.28 0.26 0.24 0.25 0.25

    Reduction Coefficient

    ILJIN ELECTRIC SIGNAL CABLE

    ZPAU RAILWAY CONTROL & SIGNALING CABLE

    Cross Section

    6

    5

    7

    8

    9

    10

    1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Core Wrapping

    6. Inner Sheath

    7. Shield

    8. Intermediate Sheath

    9. Armouring

    10. Outer Sheath

    1  2   3 4

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Railway Control & Signaling Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application

    - Used for signaling circuits in railway networks

    - Connects the signaling equipment centre to the track-side equipment

  • 8/18/2019 ILJIN Telecommunication Cables

    14/20

    Construction

    - Conductor: Annealed plain copper solid conductor

    - Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by a solid

    polyethylene skin, color-coded in accordance with telephone industry standards

    - Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group

    - Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap

    - Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap

    - Outer Sheath: Polyethylene

    Description: 

    Foam Skin PE insulated Local

    Cables are designed for duct instal-

    lation, mainly used in underground

    local network connecting exchange

    office and cross connection cabinet.

    Thin wall thickness of foam Skin

    PE insulation, combined with dry

    gas pressurization of the core,

    preserves the compactness of cable

    with good electrical performance.

     

    Foam Skin Duct Cable (Air Core)

    Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm

    Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0

    Resistance

    Unbalance (%)

    Ave. Max. 2.0 1.5 1.5 1.5

    Ind. Max. 5.0 5.0 4.0 4.0

    Dielectric Strength(kV/3sec.)

    - Conductor to Conductor DC 1.0 DC 1.2 DC 1.5 DC 1.5

    - Conductor to Ground DC 5.0 DC 5.0 DC 10.0 DC 10.0

    Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km

    Capacitance

    Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km

    Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km

    Insulation Resistance Min. 10,000 M/km

    Attenuation

    Nom. (dB/km)

    1kHz 1.9 1.5 1.2 0.85

    150kHz 12.9 9.2 7.0 5.4

    772kHz 25.9 20.7 16.7 13.0

    Electrical Characteristics at 20℃

    Frequency

    (kHz)

    Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum

    0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9

    150 61 63 63 65 57 57 57 59 58 53

    772 47 49 49 49 43 43 43 45 47 42

    1,600 41 42 43 44 37 37 37 39 43 38

    3,150 35 37 37 39 31 31 31 33 38 33

    6,300 29 31 31 33 25 25 25 27 34 29

    Crosstalk Loss (dB/305m)

    ILJIN ELECTRIC TELECOMMUNICATION CABLE

    FOAM SKIN DUCT CABLE AIR CORE

    Cross Section

    6

    5

    7

    1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Core Wrapping

    6. Shield

    7. Outer Sheath

    1  2   3   4

    Conductor Size [No/mm] Number of Pairs Conductor Size [mm] Number of Pairs

    0.4 15 ~ 3600 0.5 10 ~2400

    0.65 15 ~ 1200 0.9 25 ~ 900

    Physical Characteristics

    1  2 3

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Telecommunication C able can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application: 

    - Pressurized urban under-

    ground duct installation

    - Central offices where duct

    congestion is a prime concern

  • 8/18/2019 ILJIN Telecommunication Cables

    15/20

    Construction

    - Conductor: Annealed plain copper solid conductor

    - Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by a solid

    polyethylene skin, color-coded in accordance with telephone industry standards

    - Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group

    - Filling Compound: The entire core assembly is completely filled with ETPR compound,

    filling the interstices between the pairs and under the core tape

    - Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap

    - Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap

    - Outer Sheath: Polyethylene

    Description: 

    Foam Skin PE insulated Local

    Cables are designed for duct instal-

    lation, mainly used in underground

    local network connecting exchange

    office and cross connection cabinet.

    Thin wall thickness of foam Skin

    PE insulation, combined with dry

    gas pressurization of the core,

    preserves the compactness of cable

    with good electrical performance.

    Foam Skin Duct Cable (Jelly Filled)

    Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm

    Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0

    Resistance

    Unbalance (%)

    Ave. Max. 2.0 1.5 1.5 1.5

    Ind. Max. 5.0 5.0 4.0 4.0

    Dielectric Strength(kV/3sec.)

    - Conductor to Conductor DC 2.4 DC 3.0 DC 3.6 DC 4.5

    - Conductor to Ground DC 15.0 DC 15.0 DC 15.0 DC 15.0

    Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km

    Capacitance

    Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km

    Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km

    Insulation Resistance Min. 10,000 M/km

    Attenuation

    Nom. (dB/km)

    1kHz 1.9 1.5 1.2 0.85

    150kHz 12.2 8.9 6.4 4.8

    772kHz 23.6 19.8 15.1 11.1

    Electrical Characteristics at 20℃

    Frequency

    (kHz)

    Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum

    0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9

    150 61 63 63 65 57 57 57 59 58 53

    772 47 49 49 49 43 43 43 45 47 42

    1,600 41 42 43 44 37 37 37 39 43 38

    3,150 35 37 37 39 31 31 31 33 38 33

    6,300 29 31 31 33 25 25 25 27 34 29

    Crosstalk Loss (dB/305m)

    ILJIN ELECTRIC TELECOMMUNICATION CABLE

    FOAM SKIN DUCT CABLE JELLY FILLED

    Cross Section

    5

    7

    6

    8

    1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Filling Compound

    6. Core Wrapping

    7. Shield

    8. Outer Sheath

    1  2   3   4

    Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs

    0.4 10 ~ 3000 0.5 5 ~ 1800

    0.65 3 ~ 1200 0.9 5 ~ 600

    Physical Characteristics

    1  2 3

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application: 

    - Pressurized urban under-ground duct installation

    - Central offices where duct

    congestion is a prime concern

    - Duct installations where

    protection against water and

    moisture entry is required

  • 8/18/2019 ILJIN Telecommunication Cables

    16/20

    Construction

    - Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by

    a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap- Support Messenger: Stranded, extra high strength galvanized steel wire, fully flooded for corrosion protection- Outer Sheath: Polyethylene

    Support messenger to form a “Figure 8” configuration

    Description: 

    Foam Skin PE insulated Local

    Cables are designed for duct instal-

    lation, mainly used in underground

    local network connecting exchange

    office and cross connection cabinet.

    Thin wall thickness of foam Skin PE

    insulation, combined with dry gas

    pressurization of the core, preserves

    the compactness of cable with good

    electrical performance.

     

    Foam Skin Self Supporting Cable (Air Core)

    Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm

    Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0

    Resistance

    Unbalance (%)

    Ave. Max. 2.0 1.5 1.5 1.5

    Ind. Max. 5.0 5.0 4.0 4.0

    Dielectric Strength(kV/3sec.)

    - Conductor to Conductor DC 1.0 DC 1.2 DC 1.5 DC 1.5

    - Conductor to Ground DC 5.0 DC 5.0 DC 10.0 DC 10.0

    Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km

    Capacitance

    Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km

    Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km

    Insulation Resistance Min. 10,000 M/km

    Attenuation

    Nom. (dB/km)

    1kHz 1.9 1.5 1.2 0.85

    150kHz 12.9 9.2 7.0 5.4

    772kHz 25.9 20.7 16.7 13.0

    Electrical Characteristics at 20℃

    Frequency

    (kHz)

    Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)

    Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum

    0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9

    150 61 63 63 65 57 57 57 59 58 53772 47 49 49 49 43 43 43 45 47 421,600 41 42 43 44 37 37 37 39 43 383,150 35 37 37 39 31 31 31 33 38 336,300 29 31 31 33 25 25 25 27 34 29

    Crosstalk Loss (dB/305m)

    ILJIN ELECTRIC TELECOMMUNICATION CABLE

    FOAM SKIN SELF SUPPORTING CABLE AIR CORE

    Cross Section

    6

    7

    1

    8

    1. Support Messenger

    2. Conductor

    3. Insulation

    4. Cable Element

    5. Cable Assembly

    6. Core Wrapping

    7. Shield

    8. Outer Sheath

     3   4   5

    Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs

    0.4 15 ~ 300 0.5 10 ~ 300

    0.65 10 ~ 400 0.9 25 ~ 100

    Physical Characteristics

    2  3 4

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    2Application: - Aerial installation

  • 8/18/2019 ILJIN Telecommunication Cables

    17/20

    Frequency

    (kHz)

    Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)

    Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum

    0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9

    150 61 63 63 65 57 57 57 59 58 53

    772 47 49 49 49 43 43 43 45 47 42

    1,600 41 42 43 44 37 37 37 39 43 38

    3,150 35 37 37 39 31 31 31 33 38 33

    6,300 29 31 31 33 25 25 25 27 34 29

    Construction

    - Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by

    a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Filling Compound: The entire core assembly is completely filled with ETPR compound, filling the interstices

    between the pairs and under the core tape- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap- Support Messenger: Stranded, extra high strength galvanized steel wire, fully flooded for corrosion protection- Outer Sheath: Polyethylene

    Support messenger to form a “Figure 8” configuration

    Description: 

    Foam Skin PE insulated Local

    Cables are designed for duct instal-

    lation, mainly used in underground

    local network connecting exchange

    office and cross connection cabinet.

    Thin wall thickness of foam Skin PE

    insulation, combined with dry gas

    pressurization of the core, preserves

    the compactness of cable with good

    electrical performance.

     

    Foam Skin Self Supporting Cable (Jelly Filled)

    Conductor Size 0.4mm 0.5mm 0.65mm 0.9mmMaximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0

    ResistanceUnbalance (%) Ave. Max. 2.0 1.5 1.5 1.5Ind. Max. 5.0 5.0 4.0 4.0

    Dielectric Strength(kV/3sec.)

    - Conductor to Conductor DC 2.4 DC 3.0 DC 3.6 DC 4.5

    - Conductor to Ground DC 15.0 DC 15.0 DC 15.0 DC 15.0

    Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/kmCapacitance

    Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km

    Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km

    Insulation Resistance Min. 10,000 M/km

    Attenuation

    Nom. (dB/km)

    1kHz 1.9 1.5 1.2 0.85

    150kHz 12.2 8.9 6.4 4.8

    772kHz 23.6 19.8 15.1 11.1

    Electrical Characteristics at 20℃

    Crosstalk Loss (dB/305m)

    ILJIN ELECTRIC TELECOMMUNICATION CABLE

    FOAM SKIN SELF SUPPORTING CABLE JELLY FILLED

    Cross Section

    7

    6

    8

    9

    1. Support Messenger

    2. Conductor

    3. Insulation

    4. Cable Element

    5. Cable Assembly

    6. Filling Compound

    7. Core Wrapping

    8. Shield

    9. Outer Sheath

    2  3   4   5

    1

    Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs

    0.4 10 ~ 300 0.5 3 ~ 300

    0.65 5 ~ 200 0.9 25

    Physical Characteristics

    2  3 4

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application: - Aerial installation where

    protection against water and

    moisture entry is required

  • 8/18/2019 ILJIN Telecommunication Cables

    18/20

    Construction

    - Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by

    a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally or helically with an overlap- Inner Sheath: Polyethylene- Armouring: Galvanized steel tape applied helically over the inner sheath- Outer Sheath: Polyethylene

    Description: 

    Foam Skin PE insulated Local

    Cables are designed for duct instal-

    lation, mainly used in underground

    local network connecting exchange

    office and cross connection cabinet.

    Thin wall thickness of foam Skin PE

    insulation, combined with dry gas

    pressurization of the core, preserves

    the compactness of cable with good

    electrical performance.

    - The addition of the steel tape ar-

    mor provides increased mechanical

    protection and gopher resistance

     

    Foam Skin Direct Buried Cable (Air Core)

    Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm

    Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0

    Resistance

    Unbalance (%)

    Ave. Max. 2.0 1.5 1.5 1.5

    Ind. Max. 5.0 5.0 4.0 4.0

    Dielectric Strength(kV/3sec.)

    - Conductor to Conductor DC 1.0 DC 1.2 DC 1.5 DC 1.5

    - Conductor to Ground DC 5.0 DC 5.0 DC 10.0 DC 10.0

    Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km

    Capacitance

    Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km

    Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km

    Insulation Resistance Min. 10,000 M/km

    Attenuation

    Nom. (dB/km)

    1kHz 1.9 1.5 1.2 0.85

    150kHz 12.9 9.2 7.0 5.4

    772kHz 25.9 20.7 16.7 13.0

    Electrical Characteristics at 20℃

    Frequency

    (kHz)

    Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)

    Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum

    0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9

    150 61 63 63 65 57 57 57 59 58 53

    772 47 49 49 49 43 43 43 45 47 42

    1,600 41 42 43 44 37 37 37 39 43 38

    3,150 35 37 37 39 31 31 31 33 38 33

    6,300 29 31 31 33 25 25 25 27 34 29

    Crosstalk Loss (dB/305m)

    ILJIN ELECTRIC TELECOMMUNICATION CABLE

    FOAM SKIN DIRECT BURIED CABLE AIR CORE

    Cross Section

    5

    7

    6

    8

    9

    1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Core Wrapping

    6. Shield

    7. Inner Sheath8. Armouring

    9. Outer Sheath

    1  2   3   4

    Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs

    0.4 25 ~ 600 0.5 25 ~ 2400

    0.65 25 ~ 1200 0.9 25 ~ 900

    Physical Characteristics

    1  2 3

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application: - Direct buried installations

  • 8/18/2019 ILJIN Telecommunication Cables

    19/20

    Construction

    - Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by

    a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Filling Compound: The entire core assembly is completely filled with ETPR compound, filling the interstices

    between the pairs and under the core tape- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally or helically with an overlap- Inner Sheath: Polyethylene- Armouring: Galvanized steel tape applied helically over the inner sheath- Outer Sheath: Polyethylene

    Description: 

    Foam Skin PE insulated Local

    Cables are designed for duct instal-

    lation, mainly used in underground

    local network connecting exchange

    office and cross connection cabinet.

    Thin wall thickness of foam Skin PE

    insulation, combined with dry gas

    pressurization of the core, preserves

    the compactness of cable with good

    electrical performance.

    - The addition of the steel tape ar-

    mor provides increased mechanical

    protection and gopher resistance

    Foam Skin Direct Buried Cable (Jelly Filled)

    Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm

    Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0

    Resistance

    Unbalance (%)

    Ave. Max. 2.0 1.5 1.5 1.5

    Ind. Max. 5.0 5.0 4.0 4.0Dielectric Strength(kV/3sec.)

    - Conductor to Conductor DC 2.4 DC 3.0 DC 3.6 DC 4.5

    - Conductor to Ground DC 15.0 DC 15.0 DC 15.0 DC 15.0

    Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km

    Capacitance

    Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km

    Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km

    Insulation Resistance Min. 10,000 M/km

    Attenuation

    Nom. (dB/km)

    1kHz 1.9 1.5 1.2 0.85

    150kHz 12.2 8.9 6.4 4.8

    772kHz 23.6 19.8 15.1 11.1

    Electrical Characteristics at 20℃

    Frequency

    (kHz)

    Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)

    Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum

    0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9

    150 61 63 63 65 57 57 57 59 58 53772 47 49 49 49 43 43 43 45 47 421,600 41 42 43 44 37 37 37 39 43 383,150 35 37 37 39 31 31 31 33 38 336,300 29 31 31 33 25 25 25 27 34 29

    Crosstalk Loss (dB/305m)

    ILJIN ELECTRIC TELECOMMUNICATION CABLE

    FOAM SKIN DIRECT BURIED CABLE JELLY FILLED

    Cross Section

    6

    5

    8

    7

    9

    10

    1. Conductor

    2. Insulation

    3. Cable Element

    4. Cable Assembly

    5. Filling Compound

    6. Core Wrapping

    7. Shield

    8. Inner Sheath

    9. Armouring

    10. Outer Sheath

    1  2   3   4

    Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs

    0.4 12 ~ 600 0.5 5 ~ 600

    0.65 3 ~ 400 0.9 5 ~ 400

    Physical Characteristics

    1  2 3

    ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.

    The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.

    Application: - Direct buried installations

    where protection againstwater and moisture entry isrequired

  • 8/18/2019 ILJIN Telecommunication Cables

    20/20

    Construction

    - Conductor: Annealed plain copper stranded conductor

    - Insulation: XLPE

    - Fiber optic: Single mode (G.652) or Multi mode (50㎛, 62.5㎛)

    - Filling Compound:The fiber optic core assembly is completely filled with ETPR compound under the tube- Tube: Loose tube type (PBT)

    - Core Assembly: Wires are assembled together in a single

    - Core Wrapping: Non-hygroscopic dielectric tape applied longtudinally or helically with an overlap

    - Outer Sheath: Frame retardant halogen free po lyolefin

    Description: 

    ILJIN composite cable is suitable

    for all power limited applications

    where optical fibers are needed.

    Standard Compliances: 

    - IEC 60228

    - IEC 60332-1

    - IEC 60502-1

     

    OPTICAL FIBER & POWER WIRE COMPOSITE CABLEILJIN ELECTRIC COMPOSITE CABLE

    Cross Section

    6

    7

    8

    9

    1

    3   4  5

    2

    1. Conductor 2. Insulation 3. Fiber Optic 4. Filling Compound 5. Tube 6. Filler 7. Core Assembly 8. Core Wrapping 9. Outer Sheath

    IndexFiber

    Count

    Power Wire(Nom) Ground Wire(Nom) Thick-ness ofJacket

    [mm]

    AverageOuter Di-ameter

    [mm]

    Conduct

    Size[mm2]

    Wire No./

    Diameter[EA/mm]

    Insulation

    Thickness[mm]

    No.

    [EA]

    Conduct

    Size[mm2]

    Insulation

    Thickness[mm]

    No.

    [EA]2C+4SQMM 2

    4 7/0.85 1.2 2 4 1.2 1 1.8 16.0

    4C+4SQMM 4

    6C+4SQMM 6

    8C+4SQMM 8

    12C+4SQMM 12

    2C+6SQMM 2

    6 7/1.04 1.2 2 4 1.49 1 1.8 17.0

    4C+6SQMM 4

    6C+6SQMM 6

    8C+6SQMM 8

    12C+6SQMM 12

    2C+10SQMM 2

    10 7/1.35 1.0 2 4 1.75 1 1.8 19.0

    4C+10SQMM 4

    6C+10SQMM 6

    8C+10SQMM 8

    12C+10SQMM 122C+16SQMM 2

    16Compact

    Conductor 1.0 2 4 2.08 1 1.8 20.0

    4C+16SQMM 4

    6C+16SQMM 6

    8C+16SQMM 8

    12C+16SQMM 12

    2C+25SQMM 2

    25Compact

    Conductor 0.95 2 6 2.34 1 1.8 21.5

    4C+25SQMM 4

    6C+25SQMM 6

    8C+25SQMM 8

    12C+25SQMM 12

    2C+35SQMM 2

    35Compact

    Conductor 0.95 2 6 2.89 1 1.8 24.0

    4C+35SQMM 4

    6C+35SQMM 6

    8C+35SQMM 8

    12C+35SQMM 1212C+50SQMM 12 50

    CompactConductor

    1.06 2 10 3.09 1 1.8 27.0

    Physical Characteristics

    SizeMaximum Conductor

    Resistance [/km]Withstand Voltage

    [kV/1min]Minimum InsulationResistance [M/km]

    4SQMM 4.61

    3.5 3.67 (@90℃)

    6SQMM 3.08

    10SQMM 1.83

    16SQMM 1.15

    25SQMM 0.727

    35SQMM 0.524

    50SQMM 0.387

    Electrical Characteristics at 20℃

    The above all characteristics of ILJIN Composite Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or

    Application: - Power over Ethernet (PoE+)

    length extension

    - Combining control and

    communication in industrial

    pathways

    - Common pathway for fiber

    backbone and Class 3 power

    supply

    - 10BASE-FL

    - 100BASE-SX/100BASE-FX