iljin telecommunication cables
TRANSCRIPT
-
8/18/2019 ILJIN Telecommunication Cables
1/20
Application
- ETL Verified for guaranteed performance
- Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia
- All accepted design for global commercial network installation
- Simplified Structured cabling solution preserving long-term network investment- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- 52/155 Mb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2
- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class D)- ICEA S-90-661 (Category 5e)
- NEC/CEC Type CM/CMR
(UL 1685/1666)
- RoHS Compliant Directive
2002/95/EC
- UL 444
- KS C 3342
UTP Category 5e
Cross Section
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 538@100MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0(2.54)
PackagingType 305m(1000ft) Reelex
Weight lb/kft(kg/km) 6(9)
Materials
Conductors 24 AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.035(0.90), HDPE
Jacket in.(mm) 0.19(4.83), PVC or LSZH (Low Smoke Zero Halogen)
Technical Data
Frequency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRFPropaga-
tion DelayPropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
ns/100m(Max.)
ns/100m(Max.)
1 20.0 2.0 65.3 62.3 63.8 60.8 570 45
4 23.0 4.1 56.3 53.3 51.8 48.8 552 45
8 24.5 5.8 51.8 48.8 45.7 42.7 547 45
10 25.0 6.5 50.3 47.3 43.8 40.8 545 45
16 25.0 8.2 47.2 44.2 39.7 36.7 543 45
20 25.0 9.3 45.8 42.8 37.8 34.8 542 45
25 24.3 10.4 44.3 41.3 35.8 32.8 541 45
31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45
62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45
100 20.1 22.0 35.3 32.3 23.8 20.8 538 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
UTP CATEGORY 5E
1
2
3
4
1. Conductor
2. Insulation
3.Twisted Pair
4. Ripcord (Optional)
5. Jacket
5
-
8/18/2019 ILJIN Telecommunication Cables
2/20
Application
- ETL Verified for guaranteed performance
- Capable of handling full broadband and baseband video signals
- All accepted design for global commercial network installation
- Simplified Structured cabling solution preserving long-term network investment- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- ANSI/TIA/EIA 854: 1000 BASE-TX
- 155 Mb/s, 1.2 Gb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Digital Video
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2- ANSI/TIA 862
(Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class E)
- ICEA S-102-7000 (Category 6)
- NEC/CEC Type CM/CMR
(UL 1685/1666)
- RoHS Compliant Directive
2002/95/EC
- UL 444
- KS C 3342
UTP Category 6
Fre-
quency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay
PropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Max.)
1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45
4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45
8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45
10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45
16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45
20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45
25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45
31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45
62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45
100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45
250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
UTP CATEGORY 6
Cross Section
1
2
4
5
3
1. Conductor
2. Insulation
3. Twisted Pair
4. Cross Filler
5. Ripcord (Optional)
6. Jacket
6
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0(2.54)
PackagingType 305m(1000ft) Reelex / Reel in the box
Weight lb/kft(kg/km) 21(32) / 27(42) (In case of 24AWG)
Materials
Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.037(0.95) / 0.040(1.02), HDPE
Jacket in.(mm) 0.228(5.8) / 0.243(6.2), PVC or LSZH(Low Smoke Zero Halogen)
Technical Data
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
3/20
Application
- Foil shield reduced electromagnetic interference (EMI) for optimal performance
- ETL Verified for guaranteed performance
- Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia
- All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment
- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- 52/155 Mb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2
- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class D)
- ICEA S-90-661 (Category 5e)- NEC/CEC Type CM/CMR
(UL 1685/1666)
- RoHS Compliant Directive
2002/95/EC
- UL 444
- KS C 3342
FTP Category 5e
Frequency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRFPropaga-
tion DelayPropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
ns/100m(Max.)
ns/100m(Max.)
1 20.0 2.0 65.3 62.3 63.8 60.8 570 45
4 23.0 4.1 56.3 53.3 51.8 48.8 552 45
8 24.5 5.8 51.8 48.8 45.7 42.7 547 45
10 25.0 6.5 50.3 47.3 43.8 40.8 545 45
16 25.0 8.2 47.2 44.2 39.7 36.7 543 45
20 25.0 9.3 45.8 42.8 37.8 34.8 542 45
25 24.3 10.4 44.3 41.3 35.8 32.8 541 45
31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45
62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45
100 20.1 22.0 35.3 32.3 23.8 20.8 538 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
FTP CATEGORY 5E
Cross Section
1
2
3
4
5
6
1. Conductor
2. Insulation
3. Twisted Pair
4. Polyester Tape (Optional)
5. Drain Wire
6. Al/Mylar Tape7. Jacket
7
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 538@100MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0(2.54)
PackagingType 305m(1000ft) Reel / Reel in a Box
Weight lb/kft(kg/km) 30(46)
Materials
Conductors 24 AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.043(1.08), HDPE
Jacket in.(mm) 0.248(6.3), PVC or LSZH(Low Smoke Zero Halogen)
Technical Data
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
4/20
Application
- Foil shield reduced electromagnetic interference (EMI) for optimal performance
- ETL Verified for guaranteed performance
- Capable of handling full broadband and baseband video signals
- All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment
- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- ANSI/TIA/EIA 854: 1000 BASE-TX
- 155 Mb/s, 1.2 Gb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Digital Video
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2
- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class E)
- ICEA S-102-7000 (Category 6)
- NEC/CEC Type CM/CMR
(UL 1685/1666)
- RoHS Compliant Directive
2002/95/EC
- UL 444
- KS C 3342
FTP Category 6
Fre-
quency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay
PropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Max.)
1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45
4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45
8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45
10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45
16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45
20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45
25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45
31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45
62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45
100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45
200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45
250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
FTP CATEGORY 6
Cross Section
1
2
3
4
5
6
7
1. Conductor
2. Insulation
3. Twisted Pair
4. Cross Filler
5. Polyester Tape (Optional)
6. Drain Wire
7. Al/Mylar Tape
8. Jacket
8
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0 (2.54)
PackagingType 305m(1000ft) Reel
Weight lb/kft(kg/km) 36 (54) (In case of 24AWG)
Materials
Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.043(1.10) / 0.048(1.2), HDPE
Jacket in.(mm) 0.287 (7.3) / 0.311 (7.9), PVC or LSZH (Low Smoke Zero Halogen)
Technical Data
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
5/20
Application
- Braid & Foil shield reduced electromagnetic interference (EMI) for optimal performance
- ETL Verified for guaranteed performance
- Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia
- All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment
- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- 52/155 Mb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2
- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class D)- ICEA S-90-661 (Category 5e)
- NEC/CEC Type CM/CMR
(UL 1685/1666)
- RoHS Compliant Directive
2002/95/EC
- UL 444
S/FTP Category 5e
Frequency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRFPropaga-
tion DelayPropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
ns/100m(Max.)
ns/100m(Max.)
1 20.0 2.0 65.3 62.3 63.8 60.8 570 45
4 23.0 4.1 56.3 53.3 51.8 48.8 552 45
8 24.5 5.8 51.8 48.8 45.7 42.7 547 45
10 25.0 6.5 50.3 47.3 43.8 40.8 545 45
16 25.0 8.2 47.2 44.2 39.7 36.7 543 45
20 25.0 9.3 45.8 42.8 37.8 34.8 542 45
25 24.3 10.4 44.3 41.3 35.8 32.8 541 45
31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45
62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45100 20.1 22.0 35.3 32.3 23.8 20.8 538 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
S/FTP CATEGORY 5E
Cross Section
1
2
3
4
6
5
7
1. Conductor
2. Insulation
3. Twisted Pair
4. Polyester Tape (Optional)
5. Al/Mylar Tape6. Drain Wire
7. Tined Copper Braid
8. Jacket
8
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15
Propagation Delay ns/100m 538@100MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0(2.54)
PackagingType 305m(1000ft) Reel
Weight lb/kft(kg/km) 38(57)
Materials
Conductors 24 AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.043(1.08), HDPE
Jacket in.(mm) 0.248(6.3), PVC or LSZH (Low Smoke Zero Halogen)
Technical Data
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
6/20
Application
- Braid & Foil shield reduced electromagnetic interference (EMI) for optimal performance
- ETL Verified for guaranteed performance
- Capable of handling full broadband and baseband video signals
- All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment
- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- ANSI/TIA/EIA 854: 1000 BASE-TX
- 155 Mb/s, 1.2 Gb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Digital Video
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class E)
- ICEA S-102-7000 (Category 6)
- NEC/CEC Type CM/CMR
(UL 1685/1666)
- RoHS Compliant Directive
2002/95/EC
- UL 444
- KS C 3342
S/FTP Category 6
Fre-
quency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay
PropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Max.)
1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45
4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45
8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45
10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45
16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45
20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45
25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45
31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45
62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45
100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45
250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
S/FTP CATEGORY 6
Cross Section
1
2
3
5
4
7
6
8
1. Conductor
2. Insulation
3. Twisted Pair
4. Cross Filler
5. Polyester Tape (Optional)6. Al/Mylar Tape
7. Drain Wire
8. Tined Copper Braid
9. Jacket9
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0 (2.54)
PackagingType 305m(1000ft) Reel
Weight lb/kft(kg/km) 45 (68) (In case of 24AWG)
Materials
Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.044(1.12) / 0.049(1.25), HDPE
Jacket in.(mm) 00.311 (7.9) / 0.318 (8.1), PVC or LSZH (Low Smoke Zero Halogen)
Technical Data
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
7/20
Application
- Protects against environmental elements that can cause electrical performance failures
- ETL Verified for guaranteed performance
- Supports Fast Ethernet, Gigabit Ethernet, 155Mb/s ATM, Multimedia
- All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment
- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- 52/155 Mb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2
- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class D)- ICEA S-90-661 (Category 5e)
- ICEA S-90-661 (Category 5e)
- NEC/CEC Type CM (UL 1685)
- RoHS Compliant Directive
2002/95/EC
- UL 444
- KS C 3342
UTP Category 5e (Outdoor)
Frequency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRFPropaga-
tion DelayPropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
ns/100m(Max.)
ns/100m(Max.)
1 20.0 2.0 65.3 62.3 63.8 60.8 570 45
4 23.0 4.1 56.3 53.3 51.8 48.8 552 45
8 24.5 5.8 51.8 48.8 45.7 42.7 547 45
10 25.0 6.5 50.3 47.3 43.8 40.8 545 45
16 25.0 8.2 47.2 44.2 39.7 36.7 543 45
20 25.0 9.3 45.8 42.8 37.8 34.8 542 45
25 24.3 10.4 44.3 41.3 35.8 32.8 541 45
31.25 23.6 11.7 42.9 39.9 33.9 30.9 540 45
62.5 21.5 17.0 38.4 35.4 27.9 24.9 539 45100 20.1 22.0 35.3 32.3 23.8 20.8 538 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
UTP CATEGORY 5E OUTDOOR
Cross Section
1. Self Supporting Part
2. Conductor
3. Insulation
4. Twisted Pair5. Rip Cord(Optional)
6. Jacket
Type A Type B
4
5
2
3
1
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15
Propagation Delay ns/100m 538@100MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0(2.54)
PackagingType 305m(1000ft) Reelex/Reel
Weight lb/kft(kg/km) 17(25)
Materials
Conductors 24 AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.035(0.90), HDPE
Jacket in.(mm) 0.189(4.8), PVC or LSZH (Low Smoke Zero Halogen)
Technical Data
2 3
4
5
6 6
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
8/20
Application
- Protects against environmental elements that can cause electrical performance failures
- ETL Verified for guaranteed performance
- Capable of handling full broadband and baseband video signals
- All accepted design for global commercial network installation- Simplified Structured cabling solution preserving long-term network investment
- Electrical performance comply with ANSI/TIA-568-C.2
- Every master reel is tested for electrical performance compliance
- RoHS Compliant
Description:
- IEEE 802.3: 1000 BASE-T
(Gigabit Ethernet),
100 BASE-TX, 10 BASE-T
- ANSI/TIA/EIA 854: 1000 BASE-TX
- 155 Mb/s, 1.2 Gb/s ATM
- ANSI X3.263: 100 Mb/s
- IEEE 802.3af for DTE Power (PoE)
- IEEE 802.3at for PoE Plus
- Digital Video
- Broadband & Baseband
Analog Video
Standard Compliances :
- ANSI/TIA 568-C.2- ANSI/TIA 862 (Building Automation)
- ISO/IEC 11801 Ed. 2.0 (Class E)
- ICEA S-102-7000 (Category 6)
- NEC/CEC Type CM (UL1685)
- RoHS Compliant Directive
2002/95/EC
- UL 444
- KS C 3342
UTP Category 6 (Outdoor)
Fre-
quency
[MHz]
ReturnLoss
InsertionLoss
NEXT PSNEXT ACRF PSACRF TCL ELTCTLPropaga-tion Delay
PropagationDelay Skew
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Min.)
dB/100m(Max.)
dB/100m(Max.)
1 20.0 2.0 74.3 72.3 67.8 64.8 40.0 35.0 570 45
4 23.0 3.8 65.3 63.3 55.8 52.8 40.0 23.0 552 45
8 24.5 5.3 60.8 58.8 49.7 46.7 40.0 16.9 547 45
10 25.0 6.0 59.3 57.3 47.8 44.8 40.0 15.0 545 45
16 25.0 7.6 56.3 54.3 43.7 40.7 38.0 10.9 543 45
20 25.0 8.5 54.8 52.8 41.8 38.8 37.0 9.0 542 45
25 24.3 9.5 53.3 51.3 39.8 36.8 36.0 7.0 541 45
31.25 23.6 10.7 51.9 49.9 37.9 34.9 35.1 5.1 540 45
62.5 21.5 15.4 47.4 45.4 31.9 28.9 32.0 n/s 539 45
100 20.1 19.8 44.3 42.3 27.8 24.8 30.0 n/s 538 45200 18.0 29.0 39.8 37.8 21.8 18.8 27.0 n/s 537 45
250 17.3 32.8 38.3 36.3 19.8 16.8 26.0 n/s 536 45
Electrical Performance (ANSI/TIA-568-C.2)
ILJIN ELECTRIC LOCAL AREA NETWORK CABLE
UTP CATEGORY 6 OUTDOOR
Cross Section
1. Self Supporting Part
2. Conductor
3. Insulation
4. Twisted Pair
5. Cross Filler
6. Rip Cord(Optional)
7. Jacket
6
3 54
2
Type A Type B
1
Item Unit PVC/LSZH
Number of Pairs EA 4
Conductor DC Resistance Ohms/100m 9.38
Resistance Unbalance % 5
Mutual Capacitance nF/100m 5.6
Capacitance Unbalance pF/100m 330
Characteristic Impedance Ohms 100±15Propagation Delay ns/100m 536@250MHz
Delay Skew ns 45
Nominal Velocity of Propagation % 67
TemperatureRating
Installation ℃ 0 to +60
Operation ℃ -20 to +75
Minimum Bend Radius in.(mm) 1.0(2.54)
PackagingType 305m(1000ft) Reelex/Reel
Weight lb/kft(kg/km) 27(42) (In case of 24AWG)
Materials
Conductors 24 AWG / 23AWG, Solid Bare Annealed Copper
Insulation in.(mm) 0.037(0.95) / 0.040(1.02), HDPE
Jacket in.(mm) 0.228(5.8) / 0.243(6.2), UV-and Abrasion-Resistant PVC
Technical Data
7 7
6
4
2
53
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Local Area Network Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
9/20
Construction
- Conductor: Annealed plain copper solid conductor
- Insulation: Solid polyethylene
- Cable Element: Two insulated conductors uniformly twisted together to form a pair
- Cable Assembly: Pairs are assembled together in concentric layers
- Filling Compound: Water resistant filling compound applied to the air space within the cable core
- Core Wrapping: Non-hygroscopic tape applied over the cable assembly
- Inner Sheath: Polyethylene
- Shield : Double Copper tape
- Intermediate Sheath: Medium Density Polyethylene
- Armouring: Double helically applied steel tapes
- Outer Sheath: Polyethylene or flame retardant PVC complied with IEC 60332 part1
Description:
Pilot cables are used for control,
protection, signaling, telecommu-
nications and data transmission
purposes associated with power
distribution and transmission
systems.
Such systems are mainly operated
by the electrical supply industry
and similar applications occur in
many industrial systems.
Pilot cables are insulated with
special materials which are
designed to protect them from
the danger of induced voltages
coming from other cable circuitsin close proximity (for example,
faults in high voltage power cable
circuits).
An over voltage in the pilot cable
cores may compromise alarm
systems, prevent the proper op-
eration of protection equipment,
resulting in severe damage to the
power system.
Pilot Cable
Item Unit Value
Maximum average DC resistance of conductor /km 10.5
Maximum mutual capacitance nF/km 54
Maximum pair-to-pair capacitance unbalance pF/500m 275
Propagation constant phase shift (beta) radians at 1 kHz rad/km Approx. 0.061
Attenuation constant (alpha) dB at 1 kHz dB/km Approx. 0.52
Real/imaginary part of impedance at 1 kHz /km Approx. 3.3 / 54.4
Modulus of impedance at 1kHz Approx. 0.36
Number of Pairs Conductor Size [mm2] Average Outer Diameter [mm] Net Weight [Kg/km]
10 1.5 40 2300
Electrical Characteristics at 20℃
Physical Characteristics
ILJIN ELECTRIC SIGNAL CABLE
PILOT CABLE
Cross Section
5
6
7
8
9
10
11
1 2 3
4 1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Filling Compound
6. Core Wrapping
7. Inner Sheath
8. Shield
9. Intermediate Sheath
10. Armouring11. Outer Sheath
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Signal Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application
- Electric power distribution/transmission system
-
8/18/2019 ILJIN Telecommunication Cables
10/20
Application
Construction
- Electric power distribution/transmission system
- Conductor: Annealed plain copper solid conductor
- Insulation: Solid polyethylene
- Cable Element: Two insulated conductors uniformly twisted together to form a pair
- Cable Assembly: Pairs are assembled together in concentric layers (with binder tape (Optional))
- Filling Compound: Water resistant filling compound applied to the air space within the cable core
- Core Wrapping: Non-hygroscopic tape applied over the cable assembly
- Inner Sheath: Polyethylene
- Shield: Double copper tape
- Lead Alloy Sheath: Lead alloy sheath
- Armouring: Double helically applied steel tapes
- Outer Sheath: Polyethylene or flame retardant PVC complied with IEC 60332 part1
Description:
Supervisory/Telephone cables
are used for control, protection,
signaling, telecommunications
and data transmission purposes
associated with power distribution
and transmission systems.
Such systems are mainly operated
by the electrical supply industry
and similar applications occur in
many industrial systems.
Supervisory / Telephone cables
are insulated with special materi-
als which are designed to protect
them from the danger of induced
voltages coming from other cablecircuits in close proximity (for
example, faults in high voltage
power cable circuits).
An over voltage in the Supervi-
sory/Telephone cable cores may
compromise alarm systems,
prevent the proper operation of
protection equipment, resulting
in severe damage to the power
system.
Supervisory/Telephone Cable
Item Unit Value
Maximum average DC resistance of conductor /km 10.5
Maximum mutual capacitance nF/km 54
Maximum pair-to-pair capacitance unbalance pF/500m 275
Propagation constant phase shift (beta) radians at 1 kHz rad/km Approx. 0.061
Attenuation constant (alpha) dB at 1 kHz dB/km Approx. 0.52
Real/imaginary part of impedance at 1 kHz /km Approx. 3.3 / 54.4
Modulus of impedance at 1kHz Approx. 0.36
Number of Pairs Conductor Size [mm2] Average Outer Diameter [mm] Net Weight [Kg/km]
20 1.5 57 6800
Electrical Characteristics at 20℃
Physical Characteristics
ILJIN ELECTRIC SIGNAL CABLE
SUPERVISORY/TELEPHONE CABLE
Cross Section
5
6
7
8
9
10
11
1 2 3
4 1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Filling Compound
6. Core Wrapping
7. Inner Sheath
8. Shield
9. Lead Alloy Sheath
10. Armouring11. Outer Sheath
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Signal Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
-
8/18/2019 ILJIN Telecommunication Cables
11/20
Construction
- Conductor: Annealed plain copper solid conductor
- Insulation: Solid polyethylene
- Cabling Element: Four insulated conductors uniformly twisted together to form a quad
- Cable Assembly: Quads are helically stranded to get the cable core
- Core Wrapping: Non-hygroscopic tape applied over the cable assembly
- Inner Sheath: Polyethylene
- Shield: Corrugated copper tape
- Intermediate Sheath: Polyethylene
- Armouring: Double helically applied steel tape
- Outer Sheath: Polyethylene or flame retardant PVC complied with IEC 60332 part1
Description:
The cables are designed for con-
nection between traffic control
centers and equipment shelters
along the trackside.
The cables are specially designed
to give good induction protection.
(R.F=0.2 at inductive voltage
100V/km) and are suitable for
installation in high speed railway
lines electrified at 25kV AC.
ZCO3 (Railway Control & Signaling Cable)
Number of Quad Conductor Size [mm2] Insulated Core [mm] Average Outer Diameter [mm] Net Weight [Kg/km]
4 1 2.3 28.0 1,463
Physical Characteristics
frequency R (mΩ/m) L ( H/m) G (nS/m) C (pF/m)
2040 Hz 35.424±4% 0.8157±4% < 10 < 40
2400 Hz 35.469±4% 0.8124±4% < 10 < 40
2760 Hz 35.509±4% 0.8097±4% < 11 < 40
3120 Hz 35.558±4% 0.8074±4% < 11 < 40
62.5 kHz 54.33±4% 0.747±4% < 580 < 40
125 kHz 75.35±4% 0.7225±4% < 1248 < 40
Item Unit Value
Conductor resistance Ω/km 18.1
Insulation resistance MΩ∙km ≥5000
Voltage strength (Conductor to Conductor)(DC voltage 3min.) kV 4.5
Inductive voltage(V/km, at 60Hz) 50 70 100 370 400 470
Reduction coefficient 0.42 0.30 0.20 0.16 0.18 0.31
Electrical Characteristics at 20℃
Reduction Coefficient
Line Constant
ILJIN ELECTRIC SIGNAL CABLE
ZC03 RAILWAY CONTROL & SIGNALING CABLE
Cross Section
5
6
7
8
9
10
1 2 3
4
1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Core Wrapping
6. Inner Sheath
7. Shield
8. Intermediate Sheath
9. Armouring
10. Outer Sheath
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Railway Control & Signaling Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Standard Compliances:
- SNCF CT 445
- NF F 55-698
Application
- Automatic Train Control (ATC) system
- Used for signaling circuits in railway networks
- Connects the signaling equipment centre to the track-side equipment
-
8/18/2019 ILJIN Telecommunication Cables
12/20
* 2P cables assembly : star quad.
Construction
- Conductor: Annealed plain copper solid conductor
- Insulation: Solid polyethylene
- Cable Element: Two insulated conductors are uniformly twisted together to form a pair
- Core Assembly: Pairs are helically stranded to form the cable core
- Core Wrapping: Non-hygroscopic tape applied over the cable assembly
- Inner Sheath: Polyethylene
- Intermediate Sheath: Polyethylene
- Armouring: Double helically applied steel tape
- Outer Sheath: General PVC or flame retardant PVC complied with IEC 60332 part1 (Halogen-Free optional)
Description:
The cables are designed for con-
nection between traffic control
centers and equipment shelters
along the trackside. The cables
are specially designed to give
good induction protection and are
suitable for installation in high
speed railway lines electrified at
25kV AC.
Standard Compliances:
- SNCF CT 445
- NF C 32070 Category C2 /IEC 60332-1-2
- NF C 32070 Category C1 /
IEC 60332-3-24 (optional)
ZPFU (Railway Control & Signaling Cable)
Item Unit Value
Conductor resistance /km 18.1
Insulation resistance M∙km ≥5000
Voltage strength (Conductor to Conductor)(DC voltage 3min.) kV 4.5
Mutual capacitance (Pair to Pair) nF/km ≤55
Number of Pairs Conductor Size [mm2] Insulated Core [mm] Average Outer Diameter [mm] Net Weight [Kg/km]
2 1 2.3 15.1 441
4 1 2.3 19.3 652
7 1 2.3 23.0 951
14 1 2.3 28.0 1,364
21 1 2.3 32.3 1,750
28 1 2.3 36.0 2,116
Electrical Characteristics at 20℃
Physical Characteristics
ILJIN ELECTRIC SIGNAL CABLE
ZPFU RAILWAY CONTROL & SIGNALING CABLE
Cross Section
5
6
7
8
9
1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Core Wrapping
6. Inner Sheath
7. Intermediate Sheath
8. Armouring
9. Outer Sheath
1 2 3 4
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Railway Control & Signaling Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application
- Used for signaling circuits in railway networks
- Connects the signaling equipment centre to the track-side equipment
-
8/18/2019 ILJIN Telecommunication Cables
13/20
* Optional version ZPAU 2p x 1 mm2 , 2P x 1.5 mm2 and 1P X 5 mm2 are available for specific networks.
Construction
- Conductor: Annealed plain copper solid conductor
- Insulation: Solid polyethylene
- Cable Element: Two insulated conductors are uniformly twisted to form a pair
- Core Assembly: Pairs are helically stranded to form the cable core
- Core Wrapping: Non-hygroscopic tape applied over the cable assembly
- Inner Sheath: Polyethylene
- Shield: Corrugated copper tape
- Intermediate Sheath: Polyethylene
- Armouring: Double helically applied steel tape
- Outer Sheath: General PVC or flame retardant PVC complied with IEC 60332 part1 (Halogen-Free optional)
Description:
The cables are designed for
connection between traffic
control centers and equipment
shelters along the trackside. The
cables are specially designed to
give good induction protection
(R.C=0.26 at inductive voltage
100V/km) and are suitable for
installation in high speed railway
lines electrified at 25kV AC.
Standard Compliances:
- SNCF CT 445
- NF F 55-698- NF C 32070 Category C2 /
IEC 60332-1-2
- NF C 32070 Category C1 /
IEC 60332-3-24 (optional)
ZPAU (Railway Control & Signaling Cable)
Item Unit Value
Conductor resistance /km 18.1
Insulation resistance M∙km ≥5000
Voltage strength (Conductor to Conductor)(DC voltage 3min.) kV 4.5
Mutual capacitance (Pair to Pair) nF/km ≤55
Number of Pairs Conductor Size [mm2] Insulated Core [mm] Average Outer Diameter [mm] Net Weight [Kg/km]
4 1 2.3 22.8 1,028
7 1 2.3 25.7 1,268
14 1 2.3 30.7 1,730
21 1 2.3 35.0 2,161
28 1 2.3 38.7 2,562
Electrical Characteristics at 20℃
Physical Characteristics
Inductive voltage (V/km, at 60Hz) 28 32 37 42 47 54 70 80 100 120 170 225
Reduction coefficient 0.75 0.70 0.60 0.50 0.40 0.35 0.30 0.28 0.26 0.24 0.25 0.25
Reduction Coefficient
ILJIN ELECTRIC SIGNAL CABLE
ZPAU RAILWAY CONTROL & SIGNALING CABLE
Cross Section
6
5
7
8
9
10
1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Core Wrapping
6. Inner Sheath
7. Shield
8. Intermediate Sheath
9. Armouring
10. Outer Sheath
1 2 3 4
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Railway Control & Signaling Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application
- Used for signaling circuits in railway networks
- Connects the signaling equipment centre to the track-side equipment
-
8/18/2019 ILJIN Telecommunication Cables
14/20
Construction
- Conductor: Annealed plain copper solid conductor
- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by a solid
polyethylene skin, color-coded in accordance with telephone industry standards
- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group
- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap
- Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap
- Outer Sheath: Polyethylene
Description:
Foam Skin PE insulated Local
Cables are designed for duct instal-
lation, mainly used in underground
local network connecting exchange
office and cross connection cabinet.
Thin wall thickness of foam Skin
PE insulation, combined with dry
gas pressurization of the core,
preserves the compactness of cable
with good electrical performance.
Foam Skin Duct Cable (Air Core)
Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm
Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0
Resistance
Unbalance (%)
Ave. Max. 2.0 1.5 1.5 1.5
Ind. Max. 5.0 5.0 4.0 4.0
Dielectric Strength(kV/3sec.)
- Conductor to Conductor DC 1.0 DC 1.2 DC 1.5 DC 1.5
- Conductor to Ground DC 5.0 DC 5.0 DC 10.0 DC 10.0
Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km
Capacitance
Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km
Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km
Insulation Resistance Min. 10,000 M/km
Attenuation
Nom. (dB/km)
1kHz 1.9 1.5 1.2 0.85
150kHz 12.9 9.2 7.0 5.4
772kHz 25.9 20.7 16.7 13.0
Electrical Characteristics at 20℃
Frequency
(kHz)
Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum
0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9
150 61 63 63 65 57 57 57 59 58 53
772 47 49 49 49 43 43 43 45 47 42
1,600 41 42 43 44 37 37 37 39 43 38
3,150 35 37 37 39 31 31 31 33 38 33
6,300 29 31 31 33 25 25 25 27 34 29
Crosstalk Loss (dB/305m)
ILJIN ELECTRIC TELECOMMUNICATION CABLE
FOAM SKIN DUCT CABLE AIR CORE
Cross Section
6
5
7
1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Core Wrapping
6. Shield
7. Outer Sheath
1 2 3 4
Conductor Size [No/mm] Number of Pairs Conductor Size [mm] Number of Pairs
0.4 15 ~ 3600 0.5 10 ~2400
0.65 15 ~ 1200 0.9 25 ~ 900
Physical Characteristics
1 2 3
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Telecommunication C able can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application:
- Pressurized urban under-
ground duct installation
- Central offices where duct
congestion is a prime concern
-
8/18/2019 ILJIN Telecommunication Cables
15/20
Construction
- Conductor: Annealed plain copper solid conductor
- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by a solid
polyethylene skin, color-coded in accordance with telephone industry standards
- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group
- Filling Compound: The entire core assembly is completely filled with ETPR compound,
filling the interstices between the pairs and under the core tape
- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap
- Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap
- Outer Sheath: Polyethylene
Description:
Foam Skin PE insulated Local
Cables are designed for duct instal-
lation, mainly used in underground
local network connecting exchange
office and cross connection cabinet.
Thin wall thickness of foam Skin
PE insulation, combined with dry
gas pressurization of the core,
preserves the compactness of cable
with good electrical performance.
Foam Skin Duct Cable (Jelly Filled)
Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm
Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0
Resistance
Unbalance (%)
Ave. Max. 2.0 1.5 1.5 1.5
Ind. Max. 5.0 5.0 4.0 4.0
Dielectric Strength(kV/3sec.)
- Conductor to Conductor DC 2.4 DC 3.0 DC 3.6 DC 4.5
- Conductor to Ground DC 15.0 DC 15.0 DC 15.0 DC 15.0
Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km
Capacitance
Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km
Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km
Insulation Resistance Min. 10,000 M/km
Attenuation
Nom. (dB/km)
1kHz 1.9 1.5 1.2 0.85
150kHz 12.2 8.9 6.4 4.8
772kHz 23.6 19.8 15.1 11.1
Electrical Characteristics at 20℃
Frequency
(kHz)
Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum
0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9
150 61 63 63 65 57 57 57 59 58 53
772 47 49 49 49 43 43 43 45 47 42
1,600 41 42 43 44 37 37 37 39 43 38
3,150 35 37 37 39 31 31 31 33 38 33
6,300 29 31 31 33 25 25 25 27 34 29
Crosstalk Loss (dB/305m)
ILJIN ELECTRIC TELECOMMUNICATION CABLE
FOAM SKIN DUCT CABLE JELLY FILLED
Cross Section
5
7
6
8
1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Filling Compound
6. Core Wrapping
7. Shield
8. Outer Sheath
1 2 3 4
Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs
0.4 10 ~ 3000 0.5 5 ~ 1800
0.65 3 ~ 1200 0.9 5 ~ 600
Physical Characteristics
1 2 3
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application:
- Pressurized urban under-ground duct installation
- Central offices where duct
congestion is a prime concern
- Duct installations where
protection against water and
moisture entry is required
-
8/18/2019 ILJIN Telecommunication Cables
16/20
Construction
- Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by
a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap- Support Messenger: Stranded, extra high strength galvanized steel wire, fully flooded for corrosion protection- Outer Sheath: Polyethylene
Support messenger to form a “Figure 8” configuration
Description:
Foam Skin PE insulated Local
Cables are designed for duct instal-
lation, mainly used in underground
local network connecting exchange
office and cross connection cabinet.
Thin wall thickness of foam Skin PE
insulation, combined with dry gas
pressurization of the core, preserves
the compactness of cable with good
electrical performance.
Foam Skin Self Supporting Cable (Air Core)
Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm
Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0
Resistance
Unbalance (%)
Ave. Max. 2.0 1.5 1.5 1.5
Ind. Max. 5.0 5.0 4.0 4.0
Dielectric Strength(kV/3sec.)
- Conductor to Conductor DC 1.0 DC 1.2 DC 1.5 DC 1.5
- Conductor to Ground DC 5.0 DC 5.0 DC 10.0 DC 10.0
Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km
Capacitance
Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km
Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km
Insulation Resistance Min. 10,000 M/km
Attenuation
Nom. (dB/km)
1kHz 1.9 1.5 1.2 0.85
150kHz 12.9 9.2 7.0 5.4
772kHz 25.9 20.7 16.7 13.0
Electrical Characteristics at 20℃
Frequency
(kHz)
Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)
Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum
0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9
150 61 63 63 65 57 57 57 59 58 53772 47 49 49 49 43 43 43 45 47 421,600 41 42 43 44 37 37 37 39 43 383,150 35 37 37 39 31 31 31 33 38 336,300 29 31 31 33 25 25 25 27 34 29
Crosstalk Loss (dB/305m)
ILJIN ELECTRIC TELECOMMUNICATION CABLE
FOAM SKIN SELF SUPPORTING CABLE AIR CORE
Cross Section
6
7
1
8
1. Support Messenger
2. Conductor
3. Insulation
4. Cable Element
5. Cable Assembly
6. Core Wrapping
7. Shield
8. Outer Sheath
3 4 5
Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs
0.4 15 ~ 300 0.5 10 ~ 300
0.65 10 ~ 400 0.9 25 ~ 100
Physical Characteristics
2 3 4
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
2Application: - Aerial installation
-
8/18/2019 ILJIN Telecommunication Cables
17/20
Frequency
(kHz)
Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)
Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum
0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9
150 61 63 63 65 57 57 57 59 58 53
772 47 49 49 49 43 43 43 45 47 42
1,600 41 42 43 44 37 37 37 39 43 38
3,150 35 37 37 39 31 31 31 33 38 33
6,300 29 31 31 33 25 25 25 27 34 29
Construction
- Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by
a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Filling Compound: The entire core assembly is completely filled with ETPR compound, filling the interstices
between the pairs and under the core tape- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally with an overlap- Support Messenger: Stranded, extra high strength galvanized steel wire, fully flooded for corrosion protection- Outer Sheath: Polyethylene
Support messenger to form a “Figure 8” configuration
Description:
Foam Skin PE insulated Local
Cables are designed for duct instal-
lation, mainly used in underground
local network connecting exchange
office and cross connection cabinet.
Thin wall thickness of foam Skin PE
insulation, combined with dry gas
pressurization of the core, preserves
the compactness of cable with good
electrical performance.
Foam Skin Self Supporting Cable (Jelly Filled)
Conductor Size 0.4mm 0.5mm 0.65mm 0.9mmMaximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0
ResistanceUnbalance (%) Ave. Max. 2.0 1.5 1.5 1.5Ind. Max. 5.0 5.0 4.0 4.0
Dielectric Strength(kV/3sec.)
- Conductor to Conductor DC 2.4 DC 3.0 DC 3.6 DC 4.5
- Conductor to Ground DC 15.0 DC 15.0 DC 15.0 DC 15.0
Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/kmCapacitance
Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km
Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km
Insulation Resistance Min. 10,000 M/km
Attenuation
Nom. (dB/km)
1kHz 1.9 1.5 1.2 0.85
150kHz 12.2 8.9 6.4 4.8
772kHz 23.6 19.8 15.1 11.1
Electrical Characteristics at 20℃
Crosstalk Loss (dB/305m)
ILJIN ELECTRIC TELECOMMUNICATION CABLE
FOAM SKIN SELF SUPPORTING CABLE JELLY FILLED
Cross Section
7
6
8
9
1. Support Messenger
2. Conductor
3. Insulation
4. Cable Element
5. Cable Assembly
6. Filling Compound
7. Core Wrapping
8. Shield
9. Outer Sheath
2 3 4 5
1
Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs
0.4 10 ~ 300 0.5 3 ~ 300
0.65 5 ~ 200 0.9 25
Physical Characteristics
2 3 4
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application: - Aerial installation where
protection against water and
moisture entry is required
-
8/18/2019 ILJIN Telecommunication Cables
18/20
Construction
- Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by
a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally or helically with an overlap- Inner Sheath: Polyethylene- Armouring: Galvanized steel tape applied helically over the inner sheath- Outer Sheath: Polyethylene
Description:
Foam Skin PE insulated Local
Cables are designed for duct instal-
lation, mainly used in underground
local network connecting exchange
office and cross connection cabinet.
Thin wall thickness of foam Skin PE
insulation, combined with dry gas
pressurization of the core, preserves
the compactness of cable with good
electrical performance.
- The addition of the steel tape ar-
mor provides increased mechanical
protection and gopher resistance
Foam Skin Direct Buried Cable (Air Core)
Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm
Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0
Resistance
Unbalance (%)
Ave. Max. 2.0 1.5 1.5 1.5
Ind. Max. 5.0 5.0 4.0 4.0
Dielectric Strength(kV/3sec.)
- Conductor to Conductor DC 1.0 DC 1.2 DC 1.5 DC 1.5
- Conductor to Ground DC 5.0 DC 5.0 DC 10.0 DC 10.0
Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km
Capacitance
Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km
Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km
Insulation Resistance Min. 10,000 M/km
Attenuation
Nom. (dB/km)
1kHz 1.9 1.5 1.2 0.85
150kHz 12.9 9.2 7.0 5.4
772kHz 25.9 20.7 16.7 13.0
Electrical Characteristics at 20℃
Frequency
(kHz)
Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)
Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum
0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9
150 61 63 63 65 57 57 57 59 58 53
772 47 49 49 49 43 43 43 45 47 42
1,600 41 42 43 44 37 37 37 39 43 38
3,150 35 37 37 39 31 31 31 33 38 33
6,300 29 31 31 33 25 25 25 27 34 29
Crosstalk Loss (dB/305m)
ILJIN ELECTRIC TELECOMMUNICATION CABLE
FOAM SKIN DIRECT BURIED CABLE AIR CORE
Cross Section
5
7
6
8
9
1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Core Wrapping
6. Shield
7. Inner Sheath8. Armouring
9. Outer Sheath
1 2 3 4
Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs
0.4 25 ~ 600 0.5 25 ~ 2400
0.65 25 ~ 1200 0.9 25 ~ 900
Physical Characteristics
1 2 3
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application: - Direct buried installations
-
8/18/2019 ILJIN Telecommunication Cables
19/20
Construction
- Conductor: Annealed plain copper solid conductor- Insulation: Dual insulation consisting of an inner layer of foamed polyethylene surrounded by
a solid polyethylene skin, color-coded in accordance with telephone industry standards- Cable Element: Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk- Core Assembly: Pairs are assembled together in a single or multi group- Filling Compound: The entire core assembly is completely filled with ETPR compound, filling the interstices
between the pairs and under the core tape- Core Wrapping: Non-hygroscopic dielectric tape applied longitudinally or helically with an overlap- Shield: Copolymer-coated aluminum tape applied longitudinally or helically with an overlap- Inner Sheath: Polyethylene- Armouring: Galvanized steel tape applied helically over the inner sheath- Outer Sheath: Polyethylene
Description:
Foam Skin PE insulated Local
Cables are designed for duct instal-
lation, mainly used in underground
local network connecting exchange
office and cross connection cabinet.
Thin wall thickness of foam Skin PE
insulation, combined with dry gas
pressurization of the core, preserves
the compactness of cable with good
electrical performance.
- The addition of the steel tape ar-
mor provides increased mechanical
protection and gopher resistance
Foam Skin Direct Buried Cable (Jelly Filled)
Conductor Size 0.4mm 0.5mm 0.65mm 0.9mm
Maximum Conductor Resistance (/km) 147.5 93.5 56.5 29.0
Resistance
Unbalance (%)
Ave. Max. 2.0 1.5 1.5 1.5
Ind. Max. 5.0 5.0 4.0 4.0Dielectric Strength(kV/3sec.)
- Conductor to Conductor DC 2.4 DC 3.0 DC 3.6 DC 4.5
- Conductor to Ground DC 15.0 DC 15.0 DC 15.0 DC 15.0
Ave. Mutual Capacitance (at 1kHz) Max. Ave. 52 ± 2 nF/km
Capacitance
Unbalance(at 1kHz)Pair-Pair Aver. Max. : 45.3 pF/km Ind. Max. : 145 pF/km
Pair-Ground Ave. Max. : 574 pF/km Ind. Max. : 2,625 pF/km
Insulation Resistance Min. 10,000 M/km
Attenuation
Nom. (dB/km)
1kHz 1.9 1.5 1.2 0.85
150kHz 12.2 8.9 6.4 4.8
772kHz 23.6 19.8 15.1 11.1
Electrical Characteristics at 20℃
Frequency
(kHz)
Far End Crosstalk (FEXT) Near End Crosstalk (NEXT)
Mean Power Sum Worst Pair Power Sum Mean Power Sum Worst Power Sum
0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9 0.4 0.5 0.65 0.9
150 61 63 63 65 57 57 57 59 58 53772 47 49 49 49 43 43 43 45 47 421,600 41 42 43 44 37 37 37 39 43 383,150 35 37 37 39 31 31 31 33 38 336,300 29 31 31 33 25 25 25 27 34 29
Crosstalk Loss (dB/305m)
ILJIN ELECTRIC TELECOMMUNICATION CABLE
FOAM SKIN DIRECT BURIED CABLE JELLY FILLED
Cross Section
6
5
8
7
9
10
1. Conductor
2. Insulation
3. Cable Element
4. Cable Assembly
5. Filling Compound
6. Core Wrapping
7. Shield
8. Inner Sheath
9. Armouring
10. Outer Sheath
1 2 3 4
Conductor Size [mm] Number of Pairs Conductor Size [mm] Number of Pairs
0.4 12 ~ 600 0.5 5 ~ 600
0.65 3 ~ 400 0.9 5 ~ 400
Physical Characteristics
1 2 3
ILJIN Electric | 7F ILJIN Building, 50-1 Dohwa-dong, Mapo-gu, Seoul, Korea Copyright 2012 ILJIN Electric Co. Ltd.
The above all characteristics of ILJIN Telecommunication Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
would like to place an order, please call ILJIN Electric on +82 2 707 9104.Visit www.iljinelectric.com for more information about ILJIN Electric.
Application: - Direct buried installations
where protection againstwater and moisture entry isrequired
-
8/18/2019 ILJIN Telecommunication Cables
20/20
Construction
- Conductor: Annealed plain copper stranded conductor
- Insulation: XLPE
- Fiber optic: Single mode (G.652) or Multi mode (50㎛, 62.5㎛)
- Filling Compound:The fiber optic core assembly is completely filled with ETPR compound under the tube- Tube: Loose tube type (PBT)
- Core Assembly: Wires are assembled together in a single
- Core Wrapping: Non-hygroscopic dielectric tape applied longtudinally or helically with an overlap
- Outer Sheath: Frame retardant halogen free po lyolefin
Description:
ILJIN composite cable is suitable
for all power limited applications
where optical fibers are needed.
Standard Compliances:
- IEC 60228
- IEC 60332-1
- IEC 60502-1
OPTICAL FIBER & POWER WIRE COMPOSITE CABLEILJIN ELECTRIC COMPOSITE CABLE
Cross Section
6
7
8
9
1
3 4 5
2
1. Conductor 2. Insulation 3. Fiber Optic 4. Filling Compound 5. Tube 6. Filler 7. Core Assembly 8. Core Wrapping 9. Outer Sheath
IndexFiber
Count
Power Wire(Nom) Ground Wire(Nom) Thick-ness ofJacket
[mm]
AverageOuter Di-ameter
[mm]
Conduct
Size[mm2]
Wire No./
Diameter[EA/mm]
Insulation
Thickness[mm]
No.
[EA]
Conduct
Size[mm2]
Insulation
Thickness[mm]
No.
[EA]2C+4SQMM 2
4 7/0.85 1.2 2 4 1.2 1 1.8 16.0
4C+4SQMM 4
6C+4SQMM 6
8C+4SQMM 8
12C+4SQMM 12
2C+6SQMM 2
6 7/1.04 1.2 2 4 1.49 1 1.8 17.0
4C+6SQMM 4
6C+6SQMM 6
8C+6SQMM 8
12C+6SQMM 12
2C+10SQMM 2
10 7/1.35 1.0 2 4 1.75 1 1.8 19.0
4C+10SQMM 4
6C+10SQMM 6
8C+10SQMM 8
12C+10SQMM 122C+16SQMM 2
16Compact
Conductor 1.0 2 4 2.08 1 1.8 20.0
4C+16SQMM 4
6C+16SQMM 6
8C+16SQMM 8
12C+16SQMM 12
2C+25SQMM 2
25Compact
Conductor 0.95 2 6 2.34 1 1.8 21.5
4C+25SQMM 4
6C+25SQMM 6
8C+25SQMM 8
12C+25SQMM 12
2C+35SQMM 2
35Compact
Conductor 0.95 2 6 2.89 1 1.8 24.0
4C+35SQMM 4
6C+35SQMM 6
8C+35SQMM 8
12C+35SQMM 1212C+50SQMM 12 50
CompactConductor
1.06 2 10 3.09 1 1.8 27.0
Physical Characteristics
SizeMaximum Conductor
Resistance [/km]Withstand Voltage
[kV/1min]Minimum InsulationResistance [M/km]
4SQMM 4.61
3.5 3.67 (@90℃)
6SQMM 3.08
10SQMM 1.83
16SQMM 1.15
25SQMM 0.727
35SQMM 0.524
50SQMM 0.387
Electrical Characteristics at 20℃
The above all characteristics of ILJIN Composite Cable can be tailored to meetyour precise specifications. Whatever your requirements, if you need more information or
Application: - Power over Ethernet (PoE+)
length extension
- Combining control and
communication in industrial
pathways
- Common pathway for fiber
backbone and Class 3 power
supply
- 10BASE-FL
- 100BASE-SX/100BASE-FX