i-cat sales presentation
TRANSCRIPT
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 1/42
Imaging SciencesInternational, Inc.
Cone Beam 3-D DentalImaging System
Enhancing The Way
You See Patients
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 2/42
2
Who is Imaging Sciences International?
Since 1992, Imaging Sciences International, Inc. has been a
global leader in developing the most advanced computer
controlled dental and maxillofacial radiography products.
ISI’s marquee products: i-CAT
Panorex CMT
CommCAT
Imaging Sciences designs, develops, and produces cutting-edge imaging technologies to provide superior quality and
function that enhance the way doctors see patients. ISI is
dedicated to continually advancing imaging innovation in
the dental industry, as well as outstanding customer
service.
Meeting the Advanced Imaging Needs of Dental Professionals Since 1992
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 3/42
3
Societal Drivers Patients are increasingly demanding real-time treatment options
(instant crowns, veneers, over-dentures, implants, and braces) Increased demand for cosmetic dentistry and willingness to invest
in elective (out-of-pocket) procedures
Technology Drivers
Digital –
paperless office True anatomical information - Distortion-Free
DICOM 3 information for pre-surgical 3-D planning software,SLA models, and drill guides
Benefits to the Dental Practice
Increase productivity- generate more profit per unit chair time Increase case acceptance- uncompleted treatment proposals are
the largest non value-added activity for dentists Surgical predictability A complete continuum of care- diagnosis through treatment
Why Cone Beam 3-D Dental Imaging?
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 4/42
4
Cone Beam 3-D images provide high-definition, three
dimensional, digital data on precise anatomical information
of all oral and maxillofacial structures
~ At reduced cost to the doctor~With less radiation to the patient
Vs.
Traditional imaging systems , which are limited by
distortion, magnification changes, restricted clarity, lack of accuracy in measurements, and not allowing for 3-D
modeling
Why Cone Beam 3-D Dental Imaging?
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 5/42
5
Surgical Predictability
Saves Surgery Time/Reduce Costs
Keeps Patients In-House
Close More Cases/Increase Revenue
Decreased Medical & Legal Risks
Enhancing The WayYou See Patients
Why
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 6/42
6
Cone Beam 3-D Imaging System
3-D volumetric images
True anatomic
measurements
14 BIT Gray Scale Pan-sized footprint
Fast Scan Time
Low Radiation
Higher resolution for all
views (amorphous silicon flat
panel image sensor)
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 7/427
Effective Dose Comparison
i-CAT 20 second scan: 68 uSv Exposure is in “Pulsed” mode, actual exposure time is
about 3.5 seconds for a 20 second scan
i-CAT 10 second scan: 34 uSv
Daily background: 8 uSv
Panoramic (Average): 10-15 uSv
Digital Panoramic 4.7 – 14.9 uSv
Highest Film Pan 26 uSv
Full mouth series: 150 uSv
Medical CT 1200-3300 uSv*
Dr. Sharon Brooks, Dept. of Radiology, University of Michigan*Dr. Stuart White, Dept. of Radiology, UCLA
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 8/428
Cone Beam 3-D Imaging System
Implant Studies
Impaction
Orthognathic Surgery
TMJ Analysis
Airway Studies
Spinal Studies
Orthodontics
Enhancing The WayYou See Patients
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 9/429
Provides Complete 3-D Information to
optimize treatment planning and
placement
Locate critical anatomy Determine if bone grafting or sinus lift is
warranted
Select the most suitable implant size andtype
Optimize locations and angulations
Coordinate with Restorative Dentist
for Implants
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 10/42
10
for Implants
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 11/42
11
for Implants
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 14/42
14
3-D Implant
Visualization and Planning
DICOM 3 3rd party software. Please call for details.
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 15/42
15
for Implant
3-D Modeling and Drill Guides
DICOM 3 3rd party software. Please call for details.
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 16/42
16
More accurate 3-D views of impacted teeth
Provides more accurate 3-D views of impacted molars, impacted cuspids, andother supernumerary anomalies
Visualize impaction within the alveolarbone, location relative to adjacent teeth,and proximity to vital structures
More accurate information can result inless invasive surgery/decreased surgicaltime
for Impaction
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 17/42
17
for Impaction
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 19/42
19
for Impaction
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 20/42
20
Reposition
for Orthognathic Surgery
DICOM 3 3rd party software. Please call for details
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 21/42
21
3-D views of critical structures for complete TMJ Analysis
Provide Distortion-Free 3-D views of
critical anatomy surrounding thecondyles
Diagnosis of bone morphology, jointspace, and function
High speed-scan for open jaw views
All done quickly and comfortably
for TMJ Analysis
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 22/42
22
for TMJ Analysis
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 24/42
24
for Airway Studies
3-D data enhances airway assessment
Assess airways and determineappropriate treatments
Identify restricted airways, which may be susceptible to collapse
Diagnose infected sinuses
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 26/42
26
for Airway Studies
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 27/42
27
for Spinal Studies
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 28/42
28
for Orthodontics
Improving Orthodontic diagnosis and
treatment
Provide multiple projection perspective
Locate and diagnose pathologies
View impacted or supernumerary teeth
Assess tooth relationship to other teeth
and anatomical structures
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 29/42
29
Maxillary Crowns Mandible CrownsOcclusion
Coronal First Molar Region
for Orthodontics
Midsagittal Slice
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 30/42
30
for Orthodontics
MIP View
(Maximum Intensity Projection)
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 31/42
31
for Orthodontics
3-DVR™ (3-D Volume Rendering Software)
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 32/42
32
for Orthodontics
3-DVR™ (3-D Volume Rendering Software)
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 33/42
33
for Orthodontics
DICOM 3 3rd party software. Please call for details
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 34/42
34
for Orthodontics
DICOM 3 3rd party software. Please call for details
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 35/42
35
for Orthodontics
DICOM 3 3rd party software. Please call for details
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 36/42
36
for Orthodontics
DICOM 3 3rd party software. Please call for details
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 37/42
37
for Learning
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 38/42
38
Reduces:
Time and complication from surprises
Time for developing and duplicating x-rays
Time for retrieving x-rays from charts
Time for moving x-rays from operatory to
operatory
for Time
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 39/42
39
Internal Marketing:
Patients are amazed with the technology
Patients relate high technology with high quality
Patients leave with i-CAT reports reminding themof their experience with advanced technology andlow radiation
The report print-outs contain the Dentists’ Name,
Address, and Phone Number
Patients talk about your technology with employers,friends, and family
for Referrals
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 40/42
40
Designates Recognition:
Leader in the Field
Quality Dental Care
High Technology Office
Caring Dentist
for Recognition
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 41/42
41
Surgical Predictability Saves Surgery Time/Reduce Costs
Keeps Patients In-House
Close More Cases/Increase Revenue Decreased Medical & Legal Risks
Enhancing The WayYou See Patients
Why
8/3/2019 I-CAT Sales Presentation
http://slidepdf.com/reader/full/i-cat-sales-presentation 42/42
Imaging Sciences
International
1-800-205-3570
www.ImagingSciences.com
Enhancing The Way
You See Patients