Pressure Boosting (HYPN) SystemWhat is “HYPN” System?
HY • Hydro (liquid circulated in system by centrifugal pumps)
PN• Use of compressed air or gas
through pressurized tank in pumping system
HYPN• Conventional pumping
system converted in to automated pumping system
![Page 3: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/3.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
3
Pressure Boosting (Hydro Pneumatic) System
Maintain a constant pressure, level or temperature
Avoid unnecessary running of pumps at no flow requirement
Smooth and controlled performance
Fully automatic operation (Less human interference)
Optimization of water and energy
Why do people go for pressure boosting system?
1
2
3
4
5
![Page 4: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/4.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
4
Types of Pressure Boosting SystemTypes of HYPN System
Fixed speed system (FS)All pumps will run on fixed speed
Cascade (single VFD) System (C)One pump will run on VFD and others
pumps on fixed speed
All VFD system (AV)All pumps in system will run on VFD
![Page 5: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/5.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
5
Go to application
Storage Tank
Control Panel Pumps
Valves
Pressure Switch/ Transmitter
Pressure GaugePressure Tank
CPControl Panel
Schematic of Pressure Boosting System
![Page 6: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/6.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
6
Tank Filling System
There are 2 ways of tank filling system
Single overhead tank filling using high and low level
sensors
Multiple overhead tank filling using solenoid valve and
solenoid valve panel
Go
Go
![Page 7: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/7.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
72 May 20237
System PhotosHYPN system with vertical inline multistage pumps
![Page 8: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/8.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
82 May 20238
System Photos
HYPN system with end suction pumps
![Page 9: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/9.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
92 May 20239
System Photos
HYPN system with HSC pumps
![Page 10: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/10.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
10
Customers Trust
Shapath V Gujarat
![Page 11: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/11.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
11
Tank Filling SystemTank filling system for single overhead tank
Fixed Speed Control Panel
OHT High Level Sensor(It will give command to control panel to switch OFF pumps)
Low Level Sensor(It will give command to control panel to switch ON pumps)
Only 24 liter pressure tank to arrest water hammers
Go back
Low Level Sensor in UGTfor dry run protection
Storage Tank
![Page 12: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/12.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
12
Tank Filling SystemTank filling system for multiple overhead tank
SV SV SV SV
Click to see arrangement of Solenoid Valve panel and Solenoid Valve
Go back
OHT 1
SVP
OHT 2
SVP
OHT 3
SVP
OHT 4
SVP
SV-Solenoid valveSVP-Solenoid valve panelLevel sensor----
ST
CP
![Page 13: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/13.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
13
These level sensors will give signal to solenoid valve panel when water level in tank reaches to maximum and minimum level.
High/Low Level
Solenoid valve panel will close or open solenoid valve on receiving signal from high and low level sensors respectively.
Solenoid Valve Panel
Solenoid valve will act upon signal received from solenoid valve panel. Opening or closing of this valve will cause line pressure to change from its set pressure. This will cause HYPN system to ON or OFF pumps.
Solenoid Valve
Ball valves will act as bypass arrangement for water flow in tank in case of solenoid valve failure.
Ball ValvesBack
Tank Filling System-Component Functions
![Page 14: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/14.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
14
Ball Valve
Tank Filling SystemSolenoid Valve and Panel Arrangement
Go for individual components
Back
Solenoid Valve
OverheadTank
Solenoid Valve Panel
Water from HYPN SystemFixed Speed/Cascade/All VFD
Low level sensor
High level sensor
![Page 15: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/15.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
15
HYPN Application Area
Tank filling System from UGT to OHT
Water supply to residential building, hotels, commercial buildings, townships, airports, IT parks etc.Water transfer from one storage tank to other storage tankBottling Plant and demand based industrial applications like textile, process, automobile, power etc
Municipal corporation water supply schemes
Irrigation and Gardening system
Go back
![Page 16: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/16.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
16
Vertical inline multistage pumps See the range
Submersible pumps See the range
Horizontal multistage and monobloc pumps See the range
Single and double suction split case centrifugal pumps
See the range
KBL pump offerings in HYPN system
Back
![Page 17: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/17.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
17
KBL pump offerings in HYPN system
Back
KCIL/KSILSystem flow- up to 400mᶟ/hrSystem head- up to 240m
RKB(Cast design pump)System flow- up to 4000mᶟ/hrSystem head- up to 850m
Vertical Inline Multistage Pumps
Can be offered in any MOC
Vertical/Horizontal execution
Motors specially designed for very low noise level
![Page 18: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/18.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
18
KBL pump offerings in HYPN system
Back
KU/KS/HH (Borewell Pumps) System flow- up to 150mᶟ/hrSystem head- up to 178m
KPDS (Wet Pit Pump)System flow- up to 4000mᶟ/hrSystem head- up to 150m
KOS(Openwell Submersible Pumps)System flow- up to 40mᶟ/hrSystem head- up to 38m
Submersible Pumps
Verticalor Horizontal execution
Can be offeredin any MOC
![Page 19: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/19.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
19
KBL pump offerings in HYPN system
KDS Monobloc Pumps System flow- up to 30mᶟ/hr System head- up to 50m
Back
Horizontal Multistage and Monobloc Pumps
RKB (Cast design pump)System flow- up to 4000mᶟ/hrSystem head- up to 850m
Can be offered in any MOC
Vertical or Horizontal execution
![Page 20: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/20.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
20
KBL pump offerings in HYPN system
CE/CPHM/KPD (End suction pumps)System flow- up to 5000mᶟ/hrSystem head- up to 120m
UP/SCT/DSM/i-HT HSC Double suction pumps
Back
UP VHSC in vertical execution
Single and Double Suction Split Case Centrifugal Pump
System flow- up to 15000mᶟ/hrSystem head- up to 240m
![Page 21: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/21.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
21
KBL valves offerings in HYPN system
Back
Kirloskar/Intervalve/RB/Audco/Normex/ITAP(Any reputed make)
NRV on discharge side of pump and isolating valve one on
each side of pump to isolate pumps in case of maintenance
![Page 22: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/22.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
22
KBL offerings in HYPN system
Back
Pressure Transmitter/Pressure SwitchPurpose-To give signal to panel
Make-Danfoss/WIKA/Any reputed make
Pressure GaugePurpose-To read line pressure
Make-Fiebig/Guru/Any reputed make
![Page 23: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/23.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
23
To limit number of
start/stop for pump
To increase life of pump
To fulfill initial small flow
requirement there by
reducing power consumption
Arresting hydraulic hammers
Pressure Tank Size Calculation • Go for Formula
Purpose of Pressure Tank
Back
![Page 24: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/24.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
24
Pressure Tank Sizing Formula Q max Ps x Pa 1
Vm = 16.5 x------------x ----------- x ------- a Ps - Pa Pp
Volume of tank in liter-Fixed speed system
Flow in LPM (sum of flow of working pumps)
(Number of start/stop) /hour/pump
Pump cut-off pressure in bar
Pump cut-in pressure in bar
Precharge press of tank (It should be 0.2bar less than Pa)50% of above volume=Cascade System and 25% of above volume=All VFD System
Vm
Qm
a
Pa
Ps
Pp
Note
Back
![Page 25: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/25.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
25
Control Panel for Pressure Boosting System
HYPN System Control PanelsFixed Speed System Control Panel
Go to panel features
Cascade (single VFD) System Control Panel
Go to panel features
All VFD System Control PanelGo to panel features
Back
![Page 26: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/26.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
26
Fixed Speed System Control PanelFixed speed control panel features
Pressure switch operated (optional with pressure transmitter)
Microcontroller based control panel with IP42 enclosure class as standard (IP54 as an optional)
LED display and pressure setting through pressure switch, potential free contacts for BMS connectivity
Pump alteration, dry run protection, equal running of pumps, high pressure cut out and single phase prevention functions
Control maximum 4 number of pumps in parallel Back
![Page 27: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/27.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
27
Cascade System Control PanelCascade (single VFD) system control panel features
PLC based control panel with IP42 enclosure class as standard (IP54 as an optional), compatible with any make of VFD
Fixed or RTC based set points, alarm history of last 100 faults
Pressure sensing through pressure transmitter/sensor
Pressure setting through “4 line 20 characters HMI display”, potential free contacts for BMS connectivity
Pump alteration, single phase prevention, dry run protection, high pressure cut out, bypass provision in case of VFD failure
Control maximum 8 number of pumps in parallel with equal running of pumps
Back
![Page 28: HYPN Systems](https://reader037.vdocuments.mx/reader037/viewer/2022110108/58ef50531a28ab15538b464b/html5/thumbnails/28.jpg)
This is a proprietary document of Kirloskar Brothers Ltd.
28
All VFD System Control PanelAll VFD system control panel features
PLC based control panel with IP42 enclosure class as standard (IP54 as an optional), compatible with any make of VFD
Fixed or RTC based set points, alarm history of last 100 faults
Pressure sensing through pressure transmitter/sensor
Pressure setting through “4 line 20 characters HMI display”, RS485 card for BMS connectivity
Pump alteration, single phase prevention, dry run protection, high pressure cut out, bypass provision in case of VFD failure
Control maximum 12 number of pumps in parallel with equal running of pumps