hydraulics - nordsonemanuals.nordson.com/adhesives/3000v/manuals/partb/b1/b10201.pdf · hydraulics...

62
E 2000 Nordson Corporation All rights reserved 41-3000 V Issued 5/00 B1EN-02-[3V-X-AEXX]-1 Part B, Section 1 Hydraulics This section covers the following unit configurations. Model 3100V 3400V 3500V 3700V Voltage All Pump Piston (E) Manifold 4-Port (A) 6-Port (B or C) 2-Port (S or T) Control Vista Standard (V) Vista Pattern (PC) Vista Temperature (TC)

Upload: lamquynh

Post on 22-May-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Part B, Section 1

Hydraulics

This section covers the following unit configurations.

Model 3100V3400V3500V3700V

Voltage All

Pump Piston (E)

Manifold 4-Port (A)6-Port (B or C)2-Port (S or T)

Control Vista Standard (V)Vista Pattern (PC)Vista Temperature (TC)

Page 2: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-0

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Page 3: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-1

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Section B 1Hydraulics

WARNING: Allow only qualified personnel to perform thefollowing tasks. Follow the safety instructions in this documentand all other related documentation.

This section of the manual describes how to troubleshoot andrepair the hydraulic system. It includes

� an overview of the unit’s hydraulic system

� troubleshooting guidelines and procedures

� pump, actuator, solenoid valve, and manifold repair procedures

� pump, actuator, solenoid valve, air pressure regulator, and manifoldassembly parts lists

Refer to the parts lists at the end of this section for the part numbers ofany components that need to be replaced.

If you try all the suggestions in this section and still need assistancesolving hydraulic system problems, call your Nordson representative.

Refer to the following sections of this manual for additional information onthe hydraulic system:

� Description includes pump specifications.

� Installation includes the procedures for connecting the air supply tothe pump and installing hoses.

To replace the tank and manifold, refer to Tank. Tank includes the tankassembly parts lists.

1. Introduction

Page 4: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-2

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Two major assemblies make up the hydraulic system: an air-drivenpiston pump and a manifold. See Figure B 1-1. The pump assemblyincludes an air section, a hydraulic section, and an actuator. Themanifold assembly, which is indirectly heated by the tank, includes analuminum manifold with hose ports, a filter assembly, a drain valve, and apressure relief valve.

4130033

1

2

3

4

Fig. B 1-1 Key Parts of the Hydraulic System(shown with a typical tank and manifold)

1. Pump air section2. Pump hydraulic section

3. Manifold4. Actuator

2. Overview of theHydraulic System

Page 5: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-3

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

The following troubleshooting table describes the kinds of hydraulicsystem problems you may encounter and provides corrective actions forhandling those problems. When necessary, the table refers you to theTroubleshooting Procedures part of this section, which contains moredetailed procedures for diagnosing hydraulic system problems.

Refer to the following table to troubleshoot hydraulic system problems.

Table B 1-1Troubleshooting Hydraulic System Problems

Problem Possible Cause Corrective Action

1. Pump stroking erratically(inconsistent adhesiveoutput)(See Note A)

Adhesive level too low Check the adhesive level. Add adhesiveif necessary. Refer to Checking theAdhesive Level and Filling the Tank inOperation.

Adhesive temperature too low Check the temperature settings. Referto System Programming Procedures inInstallation.

Pump siphon ball seat dirty ormissing

Check the siphon ball seat. Refer toPump Siphon Ball Seat Check.

Pump hydraulic section dirty Clean the pump hydraulic section.Refer to Cleaning or Rebuilding thePump.

2. Pump stroking too fast(little or no adhesiveoutput)

Adhesive level too low Check the adhesive level. Add adhesiveif necessary. Refer to Checking theAdhesive Level and Filling the Tank inOperation.

Pressure relief valve defective Replace the pressure relief valve. Referto Replacing the Pressure Relief Valve.

NOTE A: The pump should make two regularly spaced exhaust sounds. If you hear two exhaust soundsfollowed by a pause, the pump is stroking erratically (the hydraulic shaft is moving faster in onedirection than the other).

Continued on next page

3. Troubleshooting

Troubleshooting Table

Page 6: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-4

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Problem Possible Cause Corrective Action

3. Pump not stroking (noadhesive output)

Pump not turned on Wait for the READY light to turn on.

NOTE: For some standard Vista andVista PC units, you may need to turnthe pump on manually after the READYlight turns on. If the auto-energizepump feature is enabled, the pump willturn on automatically.

No input air pressure to the pump Check the input air pressure. Adjust ifnecessary.

Pump solenoid valve failed Check the solenoid valve. Refer toPump Solenoid Valve Check.

Blockage in manifold Check the manifold for blockage. Referto Manifold Blockage Check.

Pump hydraulic section dirty Clean the pump hydraulic section.Refer to Cleaning or Rebuilding thePump.

Pump leaking air (causes the pump tomake a loud noise)

Locate the leak and replace damagedseals or O-rings. Refer to Pump AirSection Check.

Continued on next page

Troubleshooting Table (contd)

Page 7: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-5

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Problem Corrective ActionPossible Cause

3. Pump not stroking (noadhesive output) (contd.)

Pump actuator malfunctioning for oneor more of the following reasons:

Check for a malfunctioning actuator.Refer to Actuator Check.

� air valve binding Disassemble and clean the air valve.Refer to Cleaning or Replacing the AirValve.

� shifter fork slipped out of position Check the position of the fork andreposition if necessary. Refer toRepositioning or Replacing the ShifterFork.

� shifter fork installed upside down Check the position of the fork andreposition if necessary. The fork shouldbe positioned with the side stamped UPfacing the air motor. Refer toRepositioning or Replacing the ShifterFork.

� shifter fork bent or damaged Replace the fork. Refer to Repositioningor Replacing the Shifter Fork.

� magnet assembly dirty ordamaged

Clean or replace the magnet assembly.Refer to Cleaning or Replacing theMagnet Assembly.

� bumper assembly dirty ordamaged

Replace the bumper assembly. Refer toReplacing the Bumper Assembly.

� shifter fork magnet loose Replace the fork. Refer to Repositioningor Replacing the Shifter Fork.

Page 8: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-6

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use these procedures as directed in Table B 1-1 to further diagnosehydraulic system problems.

Manifold Blockage Check

1. Reduce the pump air pressure to 0.

2. Make sure the READY light is lit and the pump is turned on.

3. See Figure B 1-2. Place a container under the manifold drain valve,open the valve, and allow adhesive to flow from the valve.

Filter Type Procedure for Opening Drain Valve

Standard Turn the drain valve counterclockwise.

Reverse-flush With the manifold filter in the RUN position,turn the right-side drain valvecounterclockwise.

4130669A

2

3

1

Fig. B 1-2 Opening the Manifold Drain Valve

1. A manifold (standard filter)2. B or S manifold (standard filter)

3. C or T manifold (reverse-flushfilter)

Troubleshooting Procedures

Page 9: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-7

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4. Slowly increase the pump air pressure and check to see if the pumpis stroking.

Pump Action

Strokes There is no blockage in the manifold. Closethe drain valve and return to Table B 1-1.

Does not stroke The manifold may be blocked. Removeand clean the manifold filter. Refer toCleaning a Standard Manifold Filter orCleaning a Reverse-Flush Manifold Filter inMaintenance.

Pump Siphon Ball Seat Check

1. Make sure the READY light is lit and the pump is turned on.

2. See Figure B 1-2. Place a container under the manifold drain valveand open the valve.

Filter Type Procedure for Opening Drain Valve

Standard Turn the drain valve counterclockwise.

Reverse-flush With the manifold filter in the RUN position,turn the right-side drain valvecounterclockwise.

3. Turn the pump air pressure regulator alternately counterclockwiseand clockwise to increase and decrease pump air pressure. Thisshould remove any particles lodged between the siphon ball and itsseat.

4. Check to see if the pump is stroking normally or erratically.

Pump strokes Action

Normally Resume operation.

Erratically Remove and clean the pump. Refer toCleaning or Rebuilding the Pump.

Page 10: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-8

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Actuator Check

1. Remove the pump cover.

2. See Figure B 1-3. Thread an M4 screw into the top of the air valvespool.

4130032

Fig. B 1-3 Manually Shifting the Air Valve

3. Alternately press down and pull up on the screw to manually shift theair valve.

� If the air valve does not move, refer to Pump actuatormalfunctioning for one or more of the following reasons underPump does not stroke in Table B 1-1.

� If the pump strokes when the air valve is shifted but will not strokeon its own, refer to Pump actuator malfunctioning for one or moreof the following reasons under Pump does not stroke inTable B 1-1.

� If the pump does not stroke, then the pump is leaking air or isjammed. Refer to Pump Air Section Check to check for air leaks.If an air leak is not the problem, then the pump is jammed. Referto Cleaning or Rebuilding the Pump to clean the pump air orhydraulic section.

Page 11: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-9

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Solenoid Valve Check

1. Reduce the pump air pressure to 0.

2. Remove the pump cover.

3. Disconnect the air input line from the actuator.

4. Make sure the READY light is lit and the pump is turned on.

5. Slowly increase pump air pressure.

6. Check the disconnected air input line for air flow.

Condition Action

Air flows. The solenoid valve is functioning properly.Reduce the air pressure to 0, reconnect theair input line, and return to Table B 1-1.

Air does not flow. Go to the next step.

WARNING: Risk of electrical shock. Failure to observeelectrical safety procedures may result in personal injury ordeath. Allow only qualified personnel to perform the followingprocedures. Observe all high voltage indicators.

7. Open the electrical enclosure. Refer to Opening the ElectricalEnclosure in the Control section.

8. Locate connector J9 on the power board and measure the voltage atpositions 1 and 2.

Voltage Action

22.8–25.2 VDC Replace the solenoid valve. Refer to PumpSolenoid Valve Repair Procedures.

Less than 22.8 VDC Replace the power board. Refer toReplacing the Power Board in Control.

Page 12: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-10

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Air Section Check

1. Reduce the pump air pressure to 0.

2. Remove the pump cover.

3. Make sure the READY light is lit and the pump is turned on.

4. See Figure B 1-4. Slowly increase pump air pressure and check forair leaks

� at the actuator’s top or bottom exhaust port (1)

� at the top of the hydraulic shaft (2)

� between the air cylinder head and the air cylinder or between theair cylinder and the pump mount (3)

� between the actuator and air cylinder (4)

4130035

1

4

3

2

Fig. B 1-4 Checking for Pump Air Section Leaks

1. Exhaust ports2. Top of hydraulic shaft

3. Between air cylinder headand air cylinder or betweenair cylinder and pump mount

4. Between actuator and aircylinder

Page 13: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-11

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

5. Take appropriate action based on the source of the leak.

Air is Action

Not leaking Replace the pump cover and return toTable B 1-1.

Leaking from theactuator’s top or bottomexhaust port

Replace the piston cups and washers.Refer to the appropriate procedures inCleaning or Rebuilding the Pump.

Leaking from the top ofthe hydraulic shaft

Replace the U-cup. Refer to theappropriate procedures in Cleaning orRebuilding the Pump.

Leaking between the aircylinder head and theair cylinder or betweenthe air cylinder and thepump mount

Replace the air cylinder and pump mountO-rings. Refer to the appropriateprocedures in Cleaning or Rebuilding thePump.

Leaking between theactuator and the aircylinder

Replace the actuator O-rings. Refer to theappropriate procedures in Cleaning orRebuilding the Pump.

Page 14: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-12

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use these procedures to replace the piston pump, to replace any pumpcomponent, or to clean pump components. Refer to the parts lists at theend of this section for the part numbers of any components that need tobe replaced. You can also use the pump parts list illustration as a guideas you perform the following disassembly and reassembly procedures.

NOTE: If you are replacing only the actuator, you do not need to removethe pump. To replace only the actuator, complete Replacing the Actuatorin Actuator Repair Procedures.

Use these procedures to disassemble the pump, to clean or replacepump components, and to reassemble the pump.

Preparation for Pump Removal

1. Make sure the unit is at operating temperature.

2. Reduce the pump air pressure to 0.

WARNING: System or material pressurized. Relieve pressure.Failure to observe this warning may result in serious burns.

3. Relieve system pressure. Refer to Relieving System Pressure inMaintenance.

WARNING: Disconnect and lock out line voltage to the unit.Failure to observe this warning can result in personal injury ordeath.

4. Turn the unit off; then disconnect and lock out power to the unit.

5. Remove the pump cover.

6. Disconnect the air input line from the actuator.

4. Pump Repair Procedures

Cleaning or Rebuilding thePump

Page 15: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-13

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Removal

WARNING: Hot! Risk of burns. Wear heat-protective clothing,safety goggles, and heat-protective gloves.

1. If you have not already done so, complete Preparation for PumpRemoval.

2. Remove the screws and washers that secure the pump to the unit.

3. Make sure the adhesive around the pump has not solidified. Reheatif necessary.

4. Rotate the pump slightly to break the suction and pull the pumpstraight up to remove it. Lay the pump on a clean, flat work surface.

NOTE: To install a new pump and actuator assembly, go to PumpInstallation.

Page 16: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-14

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Actuator Removal

1. Move the hydraulic shaft up or down until shifter fork is centered inthe pump mount.

2. See Figure B 1-5. Remove the screws and washers (1) that securethe actuator (3); then remove the actuator.

NOTE: Series 3100V, 3400V, and 3500V units also have a pumpcover bracket (2) that must be removed.

3. Inspect the O-rings (4) in the face of the air cylinder for damage.Replace if necessary.

4130831

3 42

11

Fig. B 1-5 Removing the Actuator

1. Screw and washer2. Pump cover bracket

(Series 3100V, 3400V,and 3500V units only)

3. Actuator4. O-ring

Page 17: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-15

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Air Section Disassembly

1. Make sure you have removed the actuator. Refer to ActuatorRemoval.

2. See Figure B 1-6. Remove the screw and washer (2) from the shifterfork (1); then slide the fork toward the air cylinder and off thehydraulic shaft.

4130048

1

2

Fig. B 1-6 Removing the Shifter Fork

1. Shifter fork 2. Screw and washer

Page 18: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-16

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Air Section Disassembly (contd)

3. See Figure B 1-7. Remove the screws and lock washers (4) thatsecure the air cylinder assembly to the pump mount.

4. Remove the air cylinder head (1).

5. Inspect the air cylinder head O-ring (2) for damage. Replace ifnecessary.

6. Remove the air cylinder (3).

4130049

1

2

3

44

Fig. B 1-7 Removing the Air Cylinder

1. Air cylinder head2. Air cylinder head O-ring

3. Air cylinder4. Screw and lock washer

Page 19: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-17

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

7. See Figure B 1-8. Hold the hydraulic shaft with a wrench and removethe retaining nut at the top.

4130050

Fig. B 1-8 Removing the Hydraulic Shaft Retaining Nut

8. See Figure B 1-9. Remove the piston cup washers (3), the pistoncups (2), and the piston seal washer (1).

9. Inspect the cups and washers for damage (cracking or creasing).Replace if necessary.

4103588

3

2

3

2

1

Fig. B 1-9 Piston Cups, Piston Cup Washers, Piston Seal Washer

1. Piston seal washer2. Piston cup

3. Piston cup washer

Page 20: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-18

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Hydraulic Section Disassembly

1. See Figure B 1-10. Secure the pump with a vise and use a flat-bladescrewdriver to straighten the lock tab on the bearing lock washer.

2. Use a spanner wrench or hammer and a flat-blade screw driver toloosen the bearing lock nut. Then slide the nut and washer awayfrom the pump body.

4130052

Fig. B 1-10 Removing the Nut and Washer

3. Pull the pump mount off of the pump body.

4. See Figure B 1-11. Inspect the pump mount O-ring (1) and U-cup (3)for damage (cracking or creasing).

5. If necessary, remove the O-ring, the retaining ring (2), and the U-cup.Replace any damaged components.

4103255

3

1

2

Fig. B 1-11 Pump Mount Components

1. U-cup2. Retaining ring

3. Pump mount O-ring

Page 21: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-19

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

6. See Figure B 1-12. Inspect the pump seal (3) for damage (cracking,hardening, or creasing).

7. If necessary, use snap-ring pliers to remove the retaining ring (1).Then manually stroke the hydraulic shaft (4) up and down to loosenthe washer (2) and pump seal. Replace any damaged components.

4130114

123

4

Fig. B 1-12 Hydraulic Shaft Components

1. Retaining ring2. Washer

3. Pump seal4. Hydraulic shaft

8. See Figure B 1-13. Secure the pump body with a vise or wrench andremove the crossover tube (1), the O-ring (2), and the backupring (3).

9. Inspect the O-ring and backup ring for damage. Replace ifnecessary.

4103181

1 2

3

Fig. B 1-13 Crossover Tube, O-Ring, and Backup Ring

1. Crossover tube2. O-ring

3. Backup ring

Page 22: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-20

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Hydraulic Section Disassembly (contd)

10. See Figure B 1-14. Remove the siphon ball seat (3), siphon ball (2),and siphon ball cage (1) from the pump body.

11. Inspect the siphon ball seat for damage. Replace if necessary.

4103198

1

2

3

Fig. B 1-14 Siphon Ball Cage, Siphon Ball, and Siphon Ball Seat

1. Siphon ball cage2. Siphon ball

3. Siphon ball seat

Page 23: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-21

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

CAUTION: Risk of equipment damage. Do not scratch thehydraulic shaft or the inside of the pump body. Scratches cancause the pump to leak.

12. See Figure B 1-15. Pull the hydraulic shaft (2) out of thepump body (1).

4130054

1

2

Fig. B 1-15 Pump Body and Hydraulic Shaft

1. Pump body 2. Hydraulic shaft

Page 24: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-22

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Hydraulic Section Disassembly (contd)

13. See Figure B 1-16. Remove the pressure ball seat (3) and thepressure ball (2) from the hydraulic shaft (1).

14. Inspect the pressure ball and seat for damage. Replace if necessary.

4130113

1

2

3

Fig. B 1-16 Pressure Ball Seat and Pressure Ball

1. Hydraulic shaft2. Pressure ball

3. Pressure ball seat

Pump Component Cleaning

If necessary, use one of the following methods to clean the pumpcomponents.

WARNING: Risk of fire or explosion. Do not heat Type-Rcleaning fluid above 246 �C (475 �F). Do not heat the cleaningfluid with an open flame or in an unregulated heating device.

� Place the pump components, except for the O-rings, in a container ofType-R cleaning fluid and heat the fluid until it is above the meltingpoint of the adhesive. Scrub the components with a fine-bristledbrush and wipe them with a clean, dry cloth.

� Use a flameless, electric heat gun or compressed hot air to heat thecomponents; then wipe the components with a clean, dry cloth.

� Use an ultrasonic cleaner filled with cleaning fluid to soak thecomponents; then wipe the components with a clean, dry cloth.

Page 25: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-23

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Hydraulic Section Assembly

See the illustrations in Pump Hydraulic Section Disassembly as youperform the following reassembly steps. You can also use the pumpparts list illustration at the end of this section.

1. Remove all adhesive from the pump seal cavity and the retaining-ringgroove.

2. Apply threadlocking adhesive to the pressure ball seat threads; thenreinstall the pressure ball and seat in the hydraulic shaft. Tighten to4.07–6.78 N�m (3–5 ft-lb).

3. Insert the hydraulic shaft in the pump body.

4. Apply threadlocking adhesive to the siphon ball seat threads; thenreinstall the siphon ball cage, siphon ball, and siphon ball seat.

5. Place the crossover tube O-ring and backup ring on the crossovertube, apply anti-seize compound to the crossover tube threads, andreinstall the crossover tube.

6. If you removed the pump body retaining ring, washer, and pump seal,then

a. Apply high-temperature lubricant to seal and pull the hydraulicshaft up from the top of the pump body.

b. Secure the pump body with a vise. Place the pump seal, with thegroove facing down, on the hydraulic shaft; then install thewasher. Slide the hydraulic shaft down to help guide the seal andwasher into place in the pump body.

c. Install the retaining ring in its groove in the pump body.

7. If you removed the pump mount O-ring, retaining ring, and U-cup,then

a. Insert the U-cup in the upper face of the pump mount with thegroove facing up.

b. Press the retaining ring in the upper face to secure the U-cup.

c. Apply high-temperature lubricant to the pump mount O-ring andplace the O-ring on the upper surface of the pump mount.

Page 26: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-24

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Hydraulic Section Assembly (contd)

8. Apply high-temperature lubricant to the hydraulic shaft at the pointwhere it passes through the U-cup.

9. Guide the upper part of the pump body and the hydraulic shaftthrough the bottom hole in the pump mount.

10. Place the bearing lock washer and nut over the hydraulic shaft andslide the hydraulic shaft through the hole in the top of the pumpmount.

11. Rotate the pump body clockwise until you feel it rest against the stopin the bottom of the pump mount. Secure the pump body to the pumpmount by tightening the bearing lock nut.

12. Using a flat-blade screwdriver, lock the bearing lock washer bybending one tab into one of the slots on the bearing lock nut.

13. Slide the fork onto the hydraulic shaft until it sits on the shoulder.Make sure the side stamped UP is facing the air cylinder. Install thescrew and washer and tighten to 8–10 N�m (6–7 ft-lb).

Pump Air Section Assembly

See the illustrations in Pump Air Section Disassembly as you perform thefollowing reassembly steps. You can also use the pump parts listillustration at the end of this section.

1. Pull the hydraulic shaft up as far as possible and install the followingparts onto the shaft in this order:

a. one piston cup washerb. one piston cup with the curved edge facing downc. the piston seal washer

2. Slide the air cylinder over the hydraulic shaft and onto the pumpmount. Be careful not to damage the piston cup.

3. Use the shifter fork to move the hydraulic shaft up to the top of the aircylinder.

Page 27: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-25

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4. Install the remaining piston cup, with the curved edge facing up, andpiston cup washer on the hydraulic shaft.

5. Hold the hydraulic shaft with a wrench and replace the retaining nut.Tighten to 11.30–13.56 N�m (8–10 ft-lb).

6. Apply high-temperature lubricant to the air cylinder O-ring and rollthe O-ring into place on the air cylinder head.

7. Position the air cylinder head on the air cylinder so that the shouldercut-out is facing the actuator. Apply anti-seize compound to the aircylinder screws and use the screws and lock washers to secure theair cylinder to the pump mount. Tighten to 5–6 N�m (45–55 in.-lb).

Actuator Installation

See the illustrations in Actuator Removal as you perform the followingreassembly steps. You can also use the pump parts list illustration at theend of this section.

NOTE: Series 3100V, 3400V, and 3500V units have a pump coverbracket that must be installed when the actuator is installed. SeeFigure B 1-5.

1. If you removed the O-rings from the air cylinder face, coat four newO-rings with high-temperature lubricant and install them on the aircylinder.

2. Move the hydraulic shaft up or down until the shifter fork is in thecenter of the pump mount.

3. Carefully align the actuator with the shifter fork and the locating pinson the air cylinder.

4. Install the actuator with the screws and washers you removed earlier.Tighten to 3–4 N�m (28–36 in.-lb).

Page 28: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-26

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Pump Installation

NOTE: If you are replacing an old pump with a new, complete pump andyour old pump has a pump cover bracket, remove the bracket and installit on the new pump.

1. Make sure the pump pan is positioned correctly.

2. Lower the pump into the unit until the crossover tube seats in themanifold.

3. Secure the pump to the unit with the screws and washers youremoved earlier. Tighten to 12.20–13.56 N�m (9–10 ft-lb).

4. Connect the air input line to the actuator.

System Restoration

1. Replace the pump cover.

2. Turn the unit on and allow it to reach operating temperature.

3. See Figure B 1-17. Place a container under the manifold drain valveand open the valve.

Filter Type Procedure for Opening Drain Valve

Standard Turn the drain valve counterclockwise.

Reverse-flush With the manifold filter in the RUN position,turn the right-side drain valvecounterclockwise.

Page 29: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-27

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4130669A

2

3

1

Fig. B 1-17 Opening the Manifold Drain Valve

1. A manifold (standard filter)2. B or S manifold (standard filter)

3. C or T manifold (reverse-flushfilter)

4. Increase pump air pressure until clean adhesive flows from the drainvalve. This will purge the system of trapped air.

5. Reduce the pump air pressure to 0.

6. Close the drain valve.

7. Return the air pressure to the normal operating setting and resumeoperation.

Page 30: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-28

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use this procedure to reposition or replace the shifter fork withoutremoving the pump from the unit.

WARNING: Disconnect and lock out line voltage to the unit.Failure to observe this warning can result in personal injury ordeath.

1. Turn the unit off; then disconnect and lock out power to the unit.

2. Reduce the pump air pressure to 0.

3. Remove the pump cover.

4. Remove the actuator:

a. Move the hydraulic shaft up or down until shifter fork is centeredin the pump mount.

b. Remove the screws and washers that secure the actuator; thenremove the actuator.

NOTE: In Series 3100V, 3400V, and 3500V units have a pump coverbracket that must be removed. See Figure B 1-5.

5. See Figure B 1-18. Remove the screw and washer (2) from theshifter fork (1); then slide the fork toward the air cylinder and off thehydraulic shaft.

4130139

1

22

Fig. B 1-18 Removing the Shifter Fork

1. Shifter fork 2. Screw and washer

Repositioning or Replacing theShifter Fork

Page 31: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-29

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

6. Reposition the shifter fork or install a new shifter fork. Make sure theside of the fork stamped UP faces up.

7. Slide the fork down onto the hydraulic shaft shoulder.

8. Install the screw and washer. Tighten the screw to 8–10 N�m (71–89 in.-lb).

9. Install the actuator:

NOTE: Series 3100V, 3400V, and 3500V units have a pump coverbracket that must be installed when the actuator is installed.See Figure B 1-5.

a. Move the hydraulic shaft up or down until the shifter fork is in thecenter of the pump mount.

b. Carefully align the actuator with the shifter fork and the locatingpins on the air cylinder.

c. Install the actuator with the screws and washers you removedearlier. Tighten to 3–4 N�m (28–36 in.-lb).

10. Replace the pump cover, restore power and air to the unit, andresume operation.

Page 32: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-30

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use these procedures to clean or replace the actuator’s magnetassembly, bumper assembly, or air valve. Refer to the parts lists at theend of this section for the part numbers of any components that need tobe replaced. You can also use the actuator parts list illustration as aguide as your perform the following disassembly and reassemblyprocedures.

Use this procedure to replace the actuator without removing the pumpfrom the unit.

Actuator Removal

WARNING: Disconnect and lock out line voltage to the unit.Failure to observe this warning can result in personal injury ordeath.

1. Turn the unit off; then disconnect and lock out power to the unit.

2. Reduce the pump air pressure to 0.

3. Remove the pump cover.

4. Disconnect the air input line from the actuator and remove the air lineelbow.

5. Move the hydraulic shaft up or down until shifter fork is centered inthe pump mount.

6. See Figure B 1-19. Remove the screws and washers (1) that securethe actuator (3); then remove the actuator.

NOTE: Series 3100V, 3400V, and 3500V units have a pump coverbracket (2) that must be removed.

7. Inspect the O-rings (4) in the face of the air cylinder for damage.Replace if necessary.

5. Actuator RepairProcedures

Replacing the Actuator

Page 33: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-31

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4130831

3 42

11

Fig. B 1-19 Removing the Actuator

1. Screw and washer2. Pump cover bracket (Series

3100V, 3400V, and 3500V unitsonly)

3. Actuator4. O-ring

Actuator Installation

NOTE: Series 3100V, 3400V, and 3500V units have a pump coverbracket that must be installed when the actuator is installed. SeeFigure B 1-19.

1. If you removed the O-rings from the air cylinder face, coat four newO-rings with high-temperature lubricant and install them on the aircylinder.

2. Move the hydraulic shaft up or down until the shifter fork is in thecenter of the pump mount.

Page 34: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-32

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Actuator Installation (contd)

3. Carefully align the actuator with the shifter fork and the locating pinson the air cylinder.

4. Install the actuator with the screws and washers you removed earlier.Tighten to 3–4 N�m (28–36 in.-lb).

5. Apply PTFE paste or tape to the air line elbow threads; then installthe elbow in the actuator.

6. Connect the air input line to the actuator.

7. Replace the pump cover, restore power and air to the unit, andresume operation.

Use this procedure to clean or replace the magnet assembly. Themagnet assembly is located inside the actuator.

Magnet Assembly Removal

WARNING: Disconnect and lock out line voltage to the unit.Failure to observe this warning can result in personal injury ordeath.

1. Turn the unit off; then disconnect and lock out power to the unit.

2. Reduce the pump air pressure to 0.

3. Remove the pump cover.

4. Disconnect the air input line from the actuator.

5. Remove the actuator:

a. Move the hydraulic shaft up or down until shifter fork is centeredin the pump mount.

b. Remove the screws and washers that secure the actuator; thenremove and the actuator.

NOTE: Series 3100V, 3400V, and 3500V units have a pump coverbracket that must be removed. See Figure B 1-19.

Cleaning or Replacing theMagnet Assembly

Page 35: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-33

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

CAUTION: Use a clean work surface. The actuator containsmagnets that can pick up small particles. These particles candamage the actuator or cause poor actuator performance.

6. See Figure B 1-20. Remove the screws that attach the can to thevalve body and pull the can straight out from the valve body.

4103175

Fig. B 1-20 Removing the Can

7. Inspect the magnet assembly.

If the assembly is… Then…

Dirty or has metal particlesclinging to it

Remove the dirt or particles with aclean cloth and go to MagnetAssembly Installation.

Loose Go to step 2 of Magnet AssemblyInstallation to tighten theassembly and reinstall theactuator.

Damaged Continue with the next step.

8. Remove the valve cap screws and lift the valve cap off the bumperassembly.

Page 36: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-34

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Magnet Assembly Removal (contd)

CAUTION: Risk of equipment damage. If you use a vise tohold the valve body while removing the magnet assembly, placethe vise jaws on the sides of the valve body, not on themachined surface that mounts to the air cylinder.

9. See Figure B 1-21. Pull down on the magnet assembly and slipan awl through the hole in the shaft.

10. Hold the bumper flats with a wrench and unscrew the magnetassembly from the valve spool.

4103176

Fig. B 1-21 Removing the Magnet Assembly

Page 37: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-35

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Magnet Assembly Installation

See the illustrations in Magnet Assembly Removal as you perform thefollowing reassembly steps. You can also use the actuator parts listillustration at the end of this section.

CAUTION: Risk of equipment damage. If you use a vise tohold the valve body while removing the magnet assembly, placethe vise jaws on the sides of the valve body, not on themachined surface that mounts to the air cylinder.

1. Thread the magnet assembly into the valve spool until it seats.

2. Slip an awl through the hole in the magnet assembly shaft.

3. Using an adjustable wrench, hold the bumper flats and screw themagnet assembly into the valve spool. Tighten to 9–11 N�m (81–99 in.-lb).

4. Slide the can over the magnet assembly so the opening faces thepump assembly. Install the securing screws and tighten themto 3–4 N�m (28–36 in.-lb).

5. Install the valve cap. Tighten the valve cap screws to 3–4 N�m (28–36 in.-lb).

6. Install the actuator:

NOTE: Series 3100V, 3400V, and 3500V units have a pumpcover bracket that must be installed when the actuator is installed.See Figure B 1-19.

a. Move the hydraulic shaft up or down until the shifter fork is in thecenter of the pump mount.

b. Carefully align the actuator with the shifter fork and the locatingpins on the air cylinder.

c. Install the actuator with the screws and washers you removedearlier. Tighten to 3–4 N�m (28–36 in.-lb).

7. Connect the air input line to the actuator.

8. Replace the pump cover, restore power and air to the unit, andresume operation.

Page 38: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

4130832

1

2

3

4

5

6

7

8

HydraulicsB 1-36

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use this procedure to clean or replace the air valve assembly. The airvalve assembly is located inside the actuator.

Air Valve Removal

1. Complete Magnet Assembly Removal.

NOTE: The Magnet Assembly Removal procedure includes steps forrelieving system pressure, locking out power, and removing theactuator.

2. See Figure B 1-22. Remove the valve cap screws (1) and lift thevalve cap (2) off the bumper assembly (4).

3. Remove the bumper assembly. Use an open-end wrench to hold thebumper assembly; then use another wrench to remove the retainingnut (3).

4. Remove the upper detent (8) from the bottom of the valve body (7).

CAUTION: Risk of equipment damage. Do not press the airvalve out of the valve body by pressing on the end of the spool.

5. Use a socket or similar tool to press the air valve out of the valvebody by pressing against the end of the sleeve (6).

6. Remove and discard the sleeve O-rings (5).

Fig. B 1-22 Removing the Air Valve

1. Valve cap screw2. Valve cap3. Retaining nut4. Bumper assembly5. Sleeve o-ring6. End of sleeve7. Valve body8. Upper detent

Cleaning or Replacing the AirValve

Page 39: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-37

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

CAUTION: Risk of equipment damage. Do not clean the airvalve with an abrasive, scrape the spool or sleeve, or round offthe sharp edges of the spool lands. Doing so can damage thespool and sleeve and cause the pump to stall.

7. See Figure B 1-23. Remove the retaining screw (4) from the side ofthe sleeve (3).

8. Carefully slide the spool (2) out of the sleeve.

9. Inspect the spool lands (1).

Spool lands are… Action

Nicked, gouged, deeplyscratched, or corroded

Replace the air valve. Go to AirValve Installation.

Covered with contaminants 1. Clean the spool and sleevewith mineral spirits or anynon-chlorinated cleaningsolution, and a soft cloth. Donot use abrasives, scrape thespool or sleeve, or round offthe sharp edges of the spoollands.

2. Thoroughly wipe the valveparts with a clean cloth orrinse them with denaturedalcohol.

4103567

1

4

2

3

Fig. B 1-23 Air Valve Components

1. Spool lands2. Spool

3. Sleeve4. Retaining screw

Page 40: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-38

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Air Valve Installation

See the illustrations in Air Valve Removal as you perform the followingreassembly steps. You can also use the actuator parts list illustration atthe end of this section.

1. Apply SP pump lubricating oil to the spool lands. Refer to ActuatorParts List for the oil part number.

2. Carefully insert the spool into the sleeve and center it in the sleeve.

NOTE: The spool and sleeve are a matched set and cannot bereplaced with components from another air valve assembly.

3. Install the retaining screw. Tighten to 0.7–0.9 N�m (6–8 in.-lb).

4. Make sure the spool slides freely in its sleeve. If not, replace the airvalve and go to step 5.

5. Apply high-temperature lubricant to a new set of O-rings and installthe O-rings on the sleeve.

6. See Figure B 1-24. Press the air valve into the valve body from thetop by pushing down on the flange.

4103180

Fig. B 1-24 Installing the Air Valve

7. Install a new bumper assembly on top of the air valve.

8. Use a wrench to hold the bumper assembly flats and tighten theretaining nut. Tighten to 9–11 N�m (81–99 in.-lb).

Page 41: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

4130833

2

1

3

4

Hydraulics B 1-39

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

9. Install the upper detent on the bottom of the valve body withthe two socket-head screws removed earlier. Tighten to 1.82–2.27 N�m (16–20 in.-lb).

10. Install the valve cap. Tighten the valve cap screwsto 3–4 N�m (28–36 in.-lb).

11. Complete Magnet Assembly Installation.

Use this procedure to replace the actuator bumper assembly withoutremoving the actuator from the unit.

WARNING: Disconnect and lock out line voltage to the unit.Failure to observe this warning can result in personal injury ordeath.

1. Turn the unit off; then disconnect and lock out power to the unit.

2. Reduce the pump air pressure to 0.

3. Remove the pump cover.

4. See Figure B 1-25. Remove the valve cap screws (1) and lift thevalve cap (2) off the bumper assembly (4).

5. Remove the bumper assembly. Use an open-end wrench to hold thebumper assembly stationary; then use another wrench to remove theretaining nut (3).

6. Install a new bumper assembly and secure it with the retaining nut.Tighten the nut to 9–11 N�m (81–99 in.-lb).

7. Install the valve cap. Tighten the valve cap screws to 3–4 N�m (28–36 in.-lb).

8. Reinstall the pump cover, restore power and air to the unit, andresume operation.

Fig. B 1-25 Replacing the BumperAssembly

1. Valve cap screw2. Valve cap3. Retaining nut4. Bumper assembly

Replacing the BumperAssembly

Page 42: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-40

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use these procedures to replace the pump solenoid valve. Refer to theparts list at the end of this section for the part numbers of anycomponents that need to be replaced. You can use the solenoid valveassembly parts list illustration as a guide if you need to replace othersolenoid valve assembly components.

Follow this procedure to remove the solenoid valve. The solenoid valveis located inside the electrical enclosure.

WARNING: Disconnect and lock out line voltage to the unit.Failure to observe this warning can result in personal injury ordeath.

1. Turn the unit off; then disconnect and lock out power to the unit.

2. Reduce the pump air pressure to 0.

WARNING: Risk of electrical shock. Failure to observeelectrical safety procedures may result in personal injury ordeath. Allow only qualified personnel to perform the followingprocedures. Observe all high voltage indicators.

3. Open the electrical enclosure. Refer to Opening the ElectricalEnclosure in the Control section.

4. See Figure B 1-26. Unplug (1) the solenoid valve.

5. Disconnect the air lines (5) from the solenoid valve elbows (4).

6. Remove the screws (3) that secure the solenoid valve mountingblock (2); then remove the solenoid valve from the unit.

7. Disconnect the elbows from the solenoid valve.

6. Pump Solenoid ValveReplacementProcedures

Removing the Solenoid Valve

Page 43: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-41

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4130834A

1

2

3

35

44

3

Fig. B 1-26 Solenoid Valve Assembly Components

1. Plug2. Mounting block3. Screws

4. Elbows5. Air lines

Follow this procedure to install the new solenoid valve.

1. See Figure B 1-26. Install the elbows on the new solenoid valve.

2. Install the solenoid valve and mounting block on the back panel of theunit with the screws you removed earlier.

3. Connect the air lines to the solenoid valve elbows.

4. Connect the solenoid valve plug.

5. Close the electrical enclosure and restore power to the unit.

6. Return the pump air pressure to the normal operating setting.

7. Start the unit and listen for air leaks. If you hear air leaking, check theair line connections at the elbows.

Installing the Solenoid Valve

Page 44: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-42

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use these procedures to replace the pressure relief valve or manifolddrain valve.

Use this procedure to replace the pressure relief valve. The pressurerelief valve is located in the bottom of the tank.

1. Drain as much adhesive from the tank as possible. Refer to Flushingthe System in Maintenance for different ways to drain the tank.

2. See Figure B 1-27. Use a socket wrench to loosen the pressure reliefvalve (1); then carefully unscrew the valve and remove it.

4130835

1

2

Fig. B 1-27 Replacing the Pressure Relief Valve

1. Pressure relief valve 2. Typical tank

3. Screw the new valve into the tank until it is finger-tight.

4. Use a socket wrench to tighten the valve. Tighten to14–16 N�m (10–12 ft-lb).

5. Refill the tank with adhesive and resume operation.

7. Manifold RepairProcedures

Replacing the Pressure ReliefValve

Page 45: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-43

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Use this procedure to replace the drain valve. The drain valve is locatedin the manifold near the manifold filter.

NOTE: Units with a reverse-flush manifold filter have two drain valves.

1. Make sure the unit is at operating temperature.

WARNING: System or material pressurized. Relieve pressure.Failure to observe this warning may result in serious burns.

2. Relieve system pressure. Refer to Relieving System Pressure inMaintenance.

3. See Figure B 1-28. Remove the drain valve alignment screw (1) andwasher (2); then remove the valve (3) from the unit. Some adhesivewill flow from the valve.

41308361 23

Fig. B 1-28 Replacing the Drain Valve

1. Alignment screw2. Washer

3. Drain valve

4. Screw the new drain valve into the manifold until it is secure; thenadjust it as necessary to install and tighten the alignment screw andwasher.

5. Resume operation.

Because the manifold has no moving parts, you should not need toreplace it. However, if you need to remove the manifold for any reason,refer to Tank.

Replacing the Drain Valve

Replacing the Manifold

Page 46: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-44

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

This page left intentionally blank.

Page 47: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-45

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

To order parts, call the Nordson Customer Service Center or your localNordson representative. Use these five-column parts lists, and theaccompanying illustrations, to describe and locate parts correctly.

Numbers in the Item column correspond to numbers that identify parts inillustrations following each parts list. The code NS (not shown) indicatesthat a listed part is not illustrated. A dash (—) is used when the partnumber applies to all parts in the illustration.

The six-digit number in the Part column is the Nordson Corporation partnumber. A series of dashes in this column (- - - - - -) means the partcannot be ordered separately.

The Description column gives the part name, as well as its dimensionsand other characteristics when appropriate. Indentions show therelationships between assemblies, subassemblies, and parts.

Item Part Description Quantity Note

— 000 000 Assembly 1

1 000 000 � Subassembly 2 A

2 000 000 � � Part 1

� If you order the assembly, items 1 and 2 will be included.� If you order item 1, item 2 will be included.� If you order item 2, you will receive item 2 only.

The number in the Quantity column is the quantity required per unit,assembly, or subassembly. The code AR (As Required) is used if thepart number is a bulk item ordered in quantities or if the quantity perassembly depends on the product version or model.

Letters in the Note column refer to notes at the end of each parts list.Notes contain important information about usage and ordering. Specialattention should be given to notes.

8. Illustrated Parts Lists

Using the Illustrated Parts List

Page 48: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-46

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

See Figure B 1-29. The UpTime pack for pump E (SP 30, 14:1) providesthe parts that should be replaced as part of routine maintenance.

Item Part Description Quantity Note

— 164 601 Service kit, UpTime, pump E, SP 30, 14:1 —

1 940 111 � O-ring, Viton, 0.301 x 0.70 in. 4

2 940 332 � O-ring, Viton, 2.00 x 2.125 x 0.063 in. 2

3 984 092 � Nut, hex, lock, torque, M6, class 10 1

4 163 039 � Cup, piston 2

5 986 331 � Retaining ring, internal, 100, push-on 1

6 952 100 � Cup, U, Viton 1

7 986 602 � Retaining ring, internal, 81, inverted 1

8 273 138 � Washer, 0.799 OD x 0.543 ID x 0.034 in. 1

9 273 139 � Seal, pump 1

10 940 133 � O-ring, Viton, 0.426 ID x 0.70 in. 1

UpTime Pack for Pump E

Page 49: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-47

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4130141

7

8

9

3

4

2

5

6

2

1

11

Fig. B 1-29 Pump E UpTime Pack Parts

Page 50: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-48

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

See Figure B 1-30.

Item Part Description Quantity Note

— 161 424 Service kit, pump E, SP, 14:1, UpTime — A

1 940 111 O-ring, Viton, 0.301 ID x 0.070 in. 4

2 940 332 O-ring, Viton, 2.000 x 2.125 x 0.063 in. 2 B

3 274 523 Head, air cylinder 1

4 982 147 Screw, hex head, cap, M6 x 120 mm 4 C

5 983 409 Washer, lock, split, M6 4

6 155 058 Cylinder, air 1

7 973 466 Plug, pipe, flush, 1/16 in., w/sealant 2

8 984 092 Nut, hex, lock, torque, M6, class 10 1

9 983 446 Washer, piston cup 2

10 163 039 Cup, piston 2

11 983 445 Washer, piston seal 1

12 986 331 Retaining ring, internal, 100, push-on 1

13 952 100 Cup, U, Viton 1 B

14 120 599 Service kit, pump mount replacement 1

15 982 135 Screw, hex head, cap, M6 x 30 mm 1

16 166 880 Service kit, fork, magnetic (shifter fork) 1

17 984 545 Nut, lock, bearing, PN-08 1

18 983 184 Washer, lock, E, bearing, W-08 1

19 986 602 Retaining ring, internal, 81, inverted 1

20 273 138 Washer, 0.799 OD x 0.543 ID x 0.034 in. 1

21 273 139 Seal, pump 1

22 973 402 Plug, pipe, socket, flush, 1/8 in. 1 D

23 288 028 Body, pump 1

NOTE A: Order this part to receive a complete piston pump.B: Apply high-temperature lubricant, part 900 493.C: Apply anti-seize compound, part 900 344.D: Apply threadlocking adhesive, part 900 465.

Continued on next page

Piston Pump Parts List

Page 51: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-49

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Item Part Description Quantity Note

24 288 031 Tube, crossover, pump 1 C

25 954 013 Backup ring, single, 7/16 x 9/16 in. 1

26 940 133 O-ring, Viton, 0.426 ID x 0.070 in. 1 B

27 155 059 Piston, pump, 14:1, SP30 (hydraulic shaft) 1

28 985 302 Pin, roll, 0.125 x 0.500 in. 1

29 900 000 Ball, pressure, 440 stainless steel, 0.375 in., 50 1

30 503 709 Seat, ball, pressure 1 D

31 503 696 Cage, ball, siphon 1

32 900 001 Ball, siphon, 440 stainless steel, 0.500 in., 50 1

33 503 695 Seat, ball, siphon 1

34 983 410 Washer, flat, narrow, M6 1

35 - - - - - - Actuator assembly 1 E

36 982 298 Screw, hex head, cap, M5 x 50 mm 2 F

37 983 408 Washer, flat, narrow, M6 2 F

38 187 631 Bracket, cover, pump, 14:1, 6:1, SP30 1 F

B: Apply high-temperature lubricant, part 900 493.C: Apply anti-seize compound, part 900 344.D: Apply threadlocking adhesive, part 900 465.E: Refer to Actuator Assembly Parts List.

F: Used only on Series 3100V, 3400V, and 3500V units.

Page 52: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-50

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

Piston Pump Parts List (contd)

4130036

19

20

212

9

11

10

13

1

3

26

4

5

6

8

10

9 12

2

15

16

17

18

22

23

24

25

27

28

29

30

31

32

33

14

7

34

35

37

36

38

Fig. B 1-30 Pump E Parts

Page 53: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-51

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

This page left intentionally blank.

Page 54: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-52

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

See Figure B 1-31.

Item Part Description Quantity Note

— 155 077 Service kit, actuator assembly, SP — A

1 982 028 Screw, socket head, M5 x 20 mm 4

2 155 054 Cap, valve 1

3 984 090 Nut, hex, lock, torque, M8 1

4 161 422 Service kit, bumper 2

5 161 429 Service kit, spool/sleeve 1 B

6 940 181 O-ring, Viton, 0.739 ID x 0.070 in. 4 C

7 155 051 Body, valve 1

8 155 057 Detent, upper 1

9 982 059 Screw, socket head, M4 x 8 mm 2

10 164 606 Service kit, magnetic actuator (magnet assembly) 1

11 155 068 Can 1

12 155 067 Detent, lower 1

13 986 714 Retaining ring, internal, 156, bowed 1

NOTE A: Order this part to receive a complete actuator assembly.B: Apply SP pump lubricating oil, part 211 228, to the spool lands.C: Apply high-temperature lubricant, part 900 493.

Actuator Parts List

Page 55: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-53

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4130037

1

2

3

4

5

6

7

8

9

10

11

12

13

1

Fig. B 1-31 Actuator Parts

Page 56: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-54

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

See Figure B 1-32.

Item Part Description Quantity Note

1 982 923 Screw, cross-pan, #10-32 x 0.50 in. 2

2 338 308 Connector, male, 1/4 in. tube x 1/8 NPT 1

3 338 304 Elbow, male, 1/4 in. tube x 1/8 NPT, Viton 3

4 338 305 Elbow, male, 1/4 in. tube x 1/4 NPT, Viton 2

5 188 734 Tubing, TFE, 1/4 in. 1 A

6 275 115 Adapter, 1/4 NPTF 1

7 288 147 Grommet, 0.250 ID in. 2

8 229 519 Valve, solenoid, 2 way, 24 VDC, 1/8 in. 1

9 229 466 Block, mounting 1

10 982 309 Screw, pan head, recessed, M5 x 10 mm 1

11 - - - - - - Frame, center 1 B

12 - - - - - - Frame, hose end 1 B

13 - - - - - - Pump assembly 1 C

NOTE A: Specify required length when ordering replacement tubing.B: Refer to Frame Assembly Parts List in the Tank section.C: Refer to Piston Pump Parts List.

Solenoid Valve Assembly PartsLists

Page 57: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-55

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

4130843A

21

9

3

8

5

11

13

647

5

3

13

5

10

Fig. B 1-32 Solenoid Valve Assembly Parts

Page 58: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-56

� 2000 Nordson CorporationAll rights reserved

41-3000VIssued 5/00

B1EN-02-[3V-X-AEXX]-1

See Figure B 1-33.

Item Part Description Quantity Note

— 165 871 Regulator/filter assembly, 90 psi, 4-hose — A

— 165 872 Regulator/filter assembly, 90 psi, 6 hose — B

1 165 735 � Regulator, filter, air, 1/4 NPT 1

2 973 490 � Nipple, brass, 40, 1/4 in., 2.50 in. 1 A

2 973 491 � Nipple, brass, 40, 1/4 in., 5.00 in. 1 B

3 901 258 � Gauge, air, 1/8 NPT, 90 psi 1

4 165 870 Service kit, filter element 1

5 165 878 Service kit, filter bowl 1

NOTE A: Use only on 4-hose units.B: Use only on 6-hose units.

4103139

3

1

4

5

2

Fig. B 1-33 Air Pressure Regulator/Filter Assembly Parts

Air Pressure Regulator andFilter Assembly Parts List

Page 59: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-57

� 1999 Nordson CorporationAll rights reserved

41-3000VIssued 4/99

B1EN–03–[3V–X–AXAX]–1

The following parts lists provide replacement parts for the manifold andfilter assemblies.

4130342

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

Fig. B 1-34 Non-Circulating 4-Port Manifold with Standard Filter

Parts Lists for Manifold A

Page 60: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-58

� 1999 Nordson CorporationAll rights reserved

41-3000VIssued 4/99

B1EN–03–[3V–X–AXAX]–1

See Figure B 1-35.

Item Part Description Quantity Note

— 105 413 Manifold A, 4-port,standard filter, non-circulating 1 A

1 120 324 Service kit, valve, pressure relief, 1600 psi, 3.5 in. 1

2 983 414 Washer, flat, M, narrow, M8 5

3 288 023 Screw, special, hex-head, M8–1.25 5 B

4 973 574 Plug, O-ring, straight–thread, 9/16–18 8 B

5 940 101 O-ring, Viton, 0.239 in. ID x 0.070 in. 1

6 954 036 Backup ring, single, 1/4 in. x 3/8 in. 1

7 276 024 Valve assembly, drain 1 B

8 982 096 Screw, pan-head, slotted, M4 x 8 mm 1 B

9 983 403 Washer, lock, M, split, M4 1

10 - - - - - - Filter assembly, manifold 1 B, C

11 274 569 Adapter, filter bung 1 B, D

12 941 220 O-ring, Viton, 1.125 in. x 1.313 in. x 0.094 in. 1 E

13 940 281 O-ring, Viton, 1.375 in. x 1.500 in. x 0.063 in. 2 E

NOTE A: This part is a complete manifold assembly and includes items 1, 2, 3, and 13.B: Apply Never-Seez, part 900 341.C: Refer to Filter Assembly Parts List.D: Apply retaining cylindrical adhesive, part 900 419.E: Apply O-ring lubricant, part 900 223.

Manifold Assembly Parts List

Page 61: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

Hydraulics B 1-59

� 1999 Nordson CorporationAll rights reserved

41-3000VIssued 4/99

B1EN–03–[3V–X–AXAX]–1

4130042A

1

13

1211

10

7 4

3

28 9

6 5

Fig. B 1-35 Manifold Assembly Parts

Page 62: Hydraulics - Nordsonemanuals.nordson.com/adhesives/3000V/manuals/partb/b1/b10201.pdf · Hydraulics This section covers the following unit configurations. Model 3100V 3400V ... the

HydraulicsB 1-60

� 1999 Nordson CorporationAll rights reserved

41-3000VIssued 4/99

B1EN–03–[3V–X–AXAX]–1

See Figure B 1-36.

Item Part Description Quantity Note

— 105 432 Service kit, filter assembly 1 A

1 274 578 � Screen, filter, 0.006 mesh, 5.38 in. long 1

2 981 747 � Screw, round, 10–32 x 6.250 in. 1 B

3 274 513 � Bung, filter 1

4 941 172 � O-ring, Viton, 0.813 in. x 1.000 in. x 0.094 in. 1

5 274 579 � Core, filter, 5.718 in. long 1

NOTE A: Order this part for a complete filter assembly.B: Apply Never-Seez, part 900 341.

4130043

ÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏÏ

5

4

1

2

3

Fig. B 1-36 Filter Assembly Parts

Filter Assembly Parts List