honda o2 sensor training
TRANSCRIPT
-
7/28/2019 Honda o2 Sensor Training
1/18
LAF Sensor
Jim MooreASPIRE Inc.
-
7/28/2019 Honda o2 Sensor Training
2/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 2
Honda LAF Sensor
Allows the
stoichiometric 14.7:1
AF/R under some
conditions
But can monitor AF/R
over a much greater
range This allows it to
operate at as lean as
23:1
-
7/28/2019 Honda o2 Sensor Training
3/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 3
Zirconia O2 Sensor Operation
The Zirconia O2 Sensor used on most vehicles operates in
a very small window about .3% above and below
14.7:1AF/R
A thimble shaped Zirconia element has two sides calledelectrodes
The inside of the thimble is the reference air chamber or
where the positive lead connects, vents to ambient air.
The outside of the thimble is exposed to the exhaust side
and connects to the sensor ground.
-
7/28/2019 Honda o2 Sensor Training
4/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 4
Zirconia O2 Sensor Operation
In a chemical battery a flow of ions internally
causes a flow of electrons outside the battery
In the O2 sensor thimble the oxygen ions that flow
through it create the return signal
Oxygen ions are oxygen atoms with a charge
Outside air has more oxygen than the exhaust
creating an ion flow and eventually the O2 signal
-
7/28/2019 Honda o2 Sensor Training
5/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 5
By controlling the O2 in the diffusion chamber
you control the operating range
Chamber one is outside the chamber in
contact with the exhaust
Diffusion Chamber is between the Zirconiaelements
The air reference is at the other end
-
7/28/2019 Honda o2 Sensor Training
6/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 6
-
7/28/2019 Honda o2 Sensor Training
7/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 7
Lean Air Fuel
The LAF sensor has two Zirconia elements
that share a diffusion chamber
The LAF sensor is actually two O2 sensorsin one
One Zirconia element acts as an oxygen
pump
-
7/28/2019 Honda o2 Sensor Training
8/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 8
What do we mean when we talk
about an oxygen pump?
Remember a flow of ions creates a flow of
electrons
The inverse is also true, a flow of electronscauses a flow of ions, charging the battery
-
7/28/2019 Honda o2 Sensor Training
9/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 9
4.3K
-
7/28/2019 Honda o2 Sensor Training
10/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 10
LAF Sensor Operation
To distinguish the two Zirconia we will call
them S1 and S2
The ECM monitors the voltage between S1input and the ground lead
It tries to hold the voltage difference
between S1 and ground to 450 mV When the mixture goes rich, oxygen ions
flow from the diffusion chamber to the
exhaust
-
7/28/2019 Honda o2 Sensor Training
11/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 11
LAF Sensor Operation
The voltage on S1 input increases
The ECM detects the change and reduces
voltage on S2 input
This causes the voltage on S2 to go more
negative than the ground voltage
This causes S2 to pump oxygen out of the
diffusion chamber to the air chamber
At the same time the ECM drops voltage on
S2 input, its also reducing fuel delivery
-
7/28/2019 Honda o2 Sensor Training
12/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 12
LAF Sensor Operation
As the mixture goes leaner, oxygen ions
flow from the exhaust into the diffusion
chamber The voltage on S1 input decreases
The ECM sees the voltage drop and
increases the volt to S2 input The voltage on S2 is now more positive
than the ground voltage
-
7/28/2019 Honda o2 Sensor Training
13/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 13
LAF Sensor Operation
S2 now pumps oxygen into the diffusion
chamber from the air chamber
The voltage between S1 input and ground isheld to 450 mV
The ECM can determine how rich or lean
the exhaust is by monitoring the amperage ittakes S2 to maintain 450 mV on S1 input
-
7/28/2019 Honda o2 Sensor Training
14/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 14
LAF Sensor Operation
On a standard O2, sensor 450 mV indicates
14.7:1 AF/R
On the LAF sensor, the exhaust is at aknown value when S1 is at 450 mV
When S1 is at 450 mV and S2 is at zero
volts, the mixture is at 14.7:1 AF/R If S2 is negative its richer than 14.7:1
If S2 is positive its leaner than 14.7:1
-
7/28/2019 Honda o2 Sensor Training
15/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 15
Testing the LAF sensor
Hook a DSO positive lead to the S2 (white
wire) of the LAF sensor and the ground lead
to the LAF sensor ground (black wire) Do not use a vehicle ground you will see
nearly 2.7 volts when hooked up this way
A DMM could be hooked to the S1 terminaland again to the sensor ground to monitor
the 450 mV
-
7/28/2019 Honda o2 Sensor Training
16/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 16
Testing the LAF sensor
DSO settings
Voltage Scale: 500 mV per division
Time Base: 200 mS per division
Trigger Level: Auto on
Trigger Slope: Either way
Put the zero voltage level in the middle of thescope display
-
7/28/2019 Honda o2 Sensor Training
17/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 17
Verifying the LAF sensor
Be sure the engine is hot and the LAF
sensor is fully warmed up run at 2000 RPM
Enrich with propane the LAF sensor voltageshould go negative record the reading
Remove the propane quickly, the voltage goes
positive
-
7/28/2019 Honda o2 Sensor Training
18/18
Authored by: Joseph Marchesani Copyright 1996 Aspire Inc. 18